Central Power Research Institute

Size: px
Start display at page:

Download "Central Power Research Institute"

Transcription

1 Central Power Research Institute STDS, Govindpura, Bhopal TEST FEASIBILITY FOR VARIOUS S Sl. 1 H.V. Circuit Breaker & Switchgear Panel with Circuit Breaker 2 H.T. Switches/ Line Sectionalizer/ Capacitor Switch/ Load Break Switch - Short circuit current making and breaking IS:13118 /IEC Pub. 56, IEC , Test upto 50kArms at 12kV, Sheet 1 of 10 11kArms at 24kV, 16.0kArms at IS: 12729, 36kV. - Capacitive current IEC: , Test upto 400A, 3 at 12kV, switching IEC; , 1200A, 1 at 12kV & 15kV. - Cable/Line Charging IS:3427, Test upto 400A, 3 at 12kV, Current Breaking Test. 1200A, 1 at 12kV & 15kV. - Short time withstand IS:14659, Test upto 200kArms for 1.0 current & peak IEC: , second with 565kApeak withstand IEC-60529, current IS:12063, - Dielectric tests (wet/dry). IEC /TR , - Mechanical operation IEC , Upto 10,000 operations test at ambient air IEC temperature. BS Lightning Impulse Test upto 132kV class voltage withstand test - Temperature rise test Test upto 25,000 Amps the Upto 100 millivolt at 100Adc resistance of the main circuit. - Out-of-phase making & Test upto 50kArms at 12kV, breaking capacity 11.0kArms at 24kV, 16.0kArms at 36kV. Test upto 6.6kV& 3.3kV at 100 & 300 Amps - Inductive load Current switching - Internal arc Upto 50 karms at 12 kv, 11.0 karms at 24kV, 16.0kArms at 36kV for 0.2 second. - Test to verify the degrees of protection of enclosure - Rated short circuit making capacity - Rated making and breaking capacity - Short time withstand current and peak withstand current - Single capacitor bank switching - Dielectric tests (Wet & Dry) - Lightning Impulse Voltage withstand test - Mechanical endurance test IS:9920-1/ IEC: , IS:9920-2/ IEC: , IS:9920-3, IS:9920-4, IEC , IEC: IP-1X to 6X and IP-X1 to X6. Test upto 125kApeak at 12kV, 27.5kApeak at 24kV, 40.0kApeak at 36kV. Upto 630Amps at 12kV (3 ). Upto 800Amps at 27.5kV (1 ). 200kArrns for 1 sec. with 565kApeak Test upto 400A, 3 at 12kV, 1200A, 1 at 12kV & 15kV. Upto 1,000 operations. - Temperature rise test Test upto 10000Amps. the Upto 100 millivolt at 100Adc. resistance of the main circuit.

2 3 Isolators and Earthing Switches - Short time withstand current and peak withstand current. - Dielectric tests (wet & dry) - Mechanical endurance test IS:9921-1, IS: & 3, IS: & 5, IEC Sheet 2 of 10 Test upto 200kArms for 1.0 second with 565kA peak upto 33 kv class; upto 80kArms for 3.0 seconds with 200 ka peak for above 33 kv class. Test upto 132 kv class Upto 1,000 operations. - Temperature rise test Tests upto 6300 Amps the Upto 100 milli Volt at 100 A DC. resistance of the main circuit - Lightning Impulse Test upto 132 kv class voltage withstand test - Partial Discharge test Test upto 100 kv, 50 Hz. 4 Surge Arrestors - Short circuit tests. IS:3070-1, IS:3070-3, IEC: , IEC: , IEC: H.T. Fuses/ Distribution Fuse Boards and Cut outs - Short circuit breaking capacity test IS: , IS:9385-2, IS:9385-3, IS: , Test upto: 50 karms at 12kV, 11 karms at 24kV, For high Current test & low Current Test upto: 50 karms at 12 kv, 11 karms at 24 kv, 16 karms at 36 kv. - Dielectric Test upto 132 kv class IEC: , - Temperature rise Test. IEC: , Test upto 630 Amps. - Test for time current characteristics. IS: 2675, IS:13947 (Part-1), Test upto 100kA. - Power dissipation Test. IEC: , IS:12063,1, Upto 110 Watts. - Creepage and Clearance IEC60529 Upto 33kV. test - Test to verify the degrees of protection. 6 Line Traps Short time current IS: 8792, IS: 8793, IEC:60353 IP-1X to 6X and IP-X1 to X6 12 kv, 50 kamps for 0.2Sec. 7 Motor Terminal Box - Through fault current CPRI Document Upto 200kArms for 1.0 Sec. TOP Internal fault current Upto 50 karms for 0.2 Sec. at 12 kv, upto 11kArms for 0.2 Sec. at 24 kv, 16kArms for 0.2 Sec. at 36 kv 8 Spacers for Bundle Conductor. - Fault current IS: 10162, CPRI Document TOP-01. Upto 50 karms for 0.1 Sec. 9 Insulator strings - Power Arc tests. CPRI Document TOP HT Contactor - Rated making and Breaking Capacity IS: 9046, IEC: 60470, IS: karms at 12 kv 11 karms at 24 kv 16 karms at 36 kv Test upto 4 karms at 12kV. - Dielectric tests. Test upto l32kv Class. - Mechanical endurance Upto 12kV Class. - Temperature rise Test upto Amps with driving voltage of 40 Volts. - Dimensional Check. Upto 12kV Class. - Visual Examination. Upto 12kV Class. - Short time current Test. Upto 200 karms for 1 Second with 565kApk.

3 11 Power & Distribution Transformers, Traction Transformers, Inductors And Dry type Power transformers winding resistance. voltage ratio and check of voltage vector relationship. impedance voltage/short circuit Impedance and load loss. no-load loss and current. Insulation resistance. IS:2026-1, IS:2026-2, IS:2026-3, IS:2026-4, IEC: , IEC: , IEC: , IEC: , IEC: , IS:1180-1, IS:1180-2, IEEE C , IEEE C , IS: 11171, IEC: , IEC:60310, Upto 300 ohms. Ratio upto 400 Sheet 3 of 10 Test upto 40 MVA, 132/33 kv class Test upto 40 MVA, 132/33 kv class Upto 10 G at 5kV. - Dielectric tests. Test upto 20 MVA, 66kV Class - Lightning Impulse Voltage withstand Test. - Temperature rise Test upto 5 MVA, 66kV class; 10 MV A, 33/11kV Class Upto 25 MVA, 66kV class - Short circuit tests. Upto 60 MVA, 220 kv class subject to impedance of Transformer - Induced over voltage - Partial Discharge 100kV Measurement - Air Pressure test IS: 1180 (Part-1&2) 100 kva - Permissible flux density & over fluxing 12 Autoreclosures - Test to prove mechanical operation 1 13 Bus ducts, panels. MCB boards. Distribution pillars, distribution fuse boards and cut out etc. 14 Neutral Grounding Resistor units IS: 1180 (Part- 1 & 2) IS: 7567, ANSI/IEEE C IS:13118, IS: Test upto 1000 Volts, 200Hz, 66 kv, 120 Hz. 100kVA Upto 36kV Class. - Temperature rise Test upto 400 Amps. - Operating Duty Upto 50kArms at l2kv, 11kArms at 24kV, - Short time current Test. 200 karms for 1.0 Sec. with 565 kapeak. - Verification of the short circuit withstand strength IS 8623-I/IEC439-I, IS /IEC439-2, lec , Test upto 200kArms for 1 sec. with 565 kapk. - Short time current test lec , Test upto 100kArms for 3 sec. IEC with 250 kapk. - High voltage power lec Upto 132 kv class. frequency test IS 8084, - Temperature rise test IS 13032, Upto 25kA, 3 phase 40V. IS 5039, - Degree of protection IS 2675, IP IX to 6X & IP XI to X6. - Lightning impulse test IS 12063, - Verification of clearances and creepage distance - Verification of mechanical operation - Internal Arc Tests IS (Part-I), IS 4691, lec 60529, lec , IS 2147, IS 12063, IEC/TR operations. 200 karms for 1.0 Sec. with 565 kapeak. - Short Time Current test/ CPRI document Upto 200 karms for 1.0 sec. Temp. rise test TOP-01

4 Sheet 4 of 10 Sl. 15 Current Transformer - Short time current IS:2705 (Part -1), IS:2705 (Part-2 to 4), IEC: , Upto 200 karms for 1 Sec. with 565 kapeak subject to impedance of current Transformer. - Transient response IEC: , - Temperature rise Test upto 25,000 Amps. - Lightning impulse voltage withstand - High voltage power frequency test (dry and wet). - Determination of errors Test upto 10,000 A/1A and 5Amps. and other characteristics. - Terminal marking and polarity. - Over voltage interturn - Composite error measurement - Turn ratio measurement - Secondary winding resistance measurement - Knee point voltage and excitation current measurement - Instrument security current Partial Discharge 16 Voltage transformers - Short circuit withstand capability - Voltage Error and Phase Displacement Measurement Test - Terminal marking & Polarity - Lightning impulse voltage withstand test - High voltage power frequency test (Dry and Wet) - Temperature Rise Test - Induced Voltage Withstand Test. Partial Discharge 17 Reactors winding resistance. impedance voltage/short circuit impedance. insulation resistance. IS: 3156 (Part-1), IS: 3156 (Part-2 & 3), IEC: IEC: IS:5553-2, IS:5553-3, IS:5553-4, IS:5553-6, IS:5553-8, IEC: Test upto 100 kv, 50 Hz. Test upto 1, 132/ 3kV, 3, 33kV. Test upto 132kV class Test upto 132 kv class. Test upto 132 kv class. Upto 33 kv, 3-phase Test upto 1000 V, 200Hz Test upto 100 kv. Upto 300 ohms. Upto 2 MVAr, 11kV. Upto 10 G at 5 kv. - Dielectric tests. Test upto 132kV Class (PF) - Short time withstand current - Lightning impulse voltage withstand - Temperature Rise Test 100Amps. 200kArms for 1.0 sec. with 565 ka peak, subjected to impedance of reactors. Test upto 132kV Class.

5 2 18 ON load Tap Changer 1 19 Cables, joints and terminations of polymeric cables 20 Bushing, power connectors, Insulators 21 LV fuses, fuse holders/base, Rewirable type fuses, fuses (cutouts) Auxil1iary terminal blocks & interconnecting units, cartridge fuses, D type (AC/DC) fuses, semiconductor fuses, fuses with enclosure Sheet 5 of 10 1 High voltage test IS 8468, Upto 132 kv class 2 Temperature rise test lec , Upto 25kA, 3 ph. 3 Short circuit tests IEC: , 200kArms for 1 sec. with 565 kapk 4 Switching Test lec 60542, Upto 300kV, 700A 5 Mechanical test IS (Part-I), lec Insulation test IS 12063, 7 Lightning impulse test lec Mechanical endurance 9 Degree of protection IP 1X to 6X & IP X1 to X6 1 Dynamic & thermal short IS 13573, Test upto 200kArms for 1 sec. With circuit test IS 1554 (Part- 1& 2), 565 kapk. IS 5819, 2 Lightning Impulse test Upto 132 kv class. IS 7098 (Part-I), 3 Dielectric test IS 7098 (Part-2), CPRI 100 kv class. 4 Conductor resistance test Document TOP-02 Upto Insulation resistance meas. Upto 10G at 5kV. 1 Short time current test IS 2099, 2 HV power frequency test Lightning impulse test 3 Temperature rise test 4 Visual inspection 5 Electrical routine test 6 Verification of dimensions 7 Puncture test IS 7421, IS 5561, IS 5621, IS 2544, IS 731, lec Breaking capacity tests** IS (Part-1), Performance under short 2 circuit conditions** Cut-off current 3 characteristics* * 4 I2 t characteristics and over current discrimination** Mechanical strength of 5 fuse holder Verification of resistance 6 To heat Non-deterioration of insulating parts of fuse 7 links, fuse base and contacts Protection against 8 electric shock 9 Temperature rise test IS (Part-2/Sec.1), IS (Part-2/Sec.2), IS 2086, BS 88 (Part-I), BS 1361, BS 7657, IS 8187, IS (Part-4), IEC , IEC , IEC , IEC , IS 10027, IS 10027, IS 13947(Part-I), IEC IS karms for 3 secs. with 250kApk. Upto 132kV class Upto 25kA, 3 ph. with driving voltage of 40V, Upto 132 kv class. **Range- Test upto 200kArms at 1.1 kv and upto 80 ka d.c at 1.55 kvd.c. # 100kArms at 550V and upto 80kA Upto 1250A, 1000V Upto 1250A, 1000V Upto 1250A, 1000V Upto 1250A, 1000V Upto 25kA, 3 ph. with driving voltage of 40V. 10 Degree of protection IP1X to 6X & IPX1 tox6 Time current Upto 1250A, 1000V rating. 11 characteristics** Conventional time and 100kArms at 550V and upto 12 current** 80kArms a 13 Visual examination Upto 100Amps, 415V. 14 Test for dimensions Upto 100Amps, 415V. 15 Mechanical endurance Upto 100Amps, 415V. 16 Mechanical strength Upto 100Amps, 415V. 17 Withdrawal force Upto 100Amps, 415V. 18 Insulation resistance Upto 2000M, 500V. 19 Dielectric test Upto 10kV. 20 Electrical endurance** -- Test for water absorption 21 (Non ceramic) Upto 100Amps, 415V. Test for water absorption on 22 ceramic material Upto 100Amps, 415V. 23 Temperature cycle test Upto 100Amps, 415V. 24 Verification of the continuity of the protective circuit

6 22 L V Switchgear and Control gear Sheet 6 of 10 1 Making & breaking IS/IEC , Range - 100kA for 3 secs. Capacity IS/IEC , 550V, 80 ka for 3 secs. 726V 2 Short circuit making IS/IEC , Capacity IS/IEC , Upto 200 ka for 1 sec. with Short time withstand current IS/IEC , kapk at 1.1 kv and upto 80 kadc lec , at 1.55 kvdc. 4 Fuse protected short lec , circuit withstand lec , lec , 5 Fuse protected short circuit lec , making lec , 6 Rated service short circuit lec , breaking capacity lec , 7 Rated ultimate short circuit IS/IEC , breaking capacity IS/IEC , Rated short time withstand lec , 8 current IEC: , 9 Short circuit Breaking IS (Part-I), capacity at Maximum short IS (Part-2), time withstand current IS3427,/IEC:298 lec , 10 Short circuit at selectivity limit lec , current. * lec , 11 Short circuit at 1.1 times lec , protective current* lec , lec , 12 Short circuit at ultimate short IS 10027, circuit breaking capacity* lec 60755, IS 13032, 13 Individual pole short lec /0, circuit breaking capacity* IS 14659, 14 Switching duty test* lec 60466, 15 Verification of rated IS 9000(Part-VIII) making and breaking capacities, change over ability and reversibility* 16 Discrimination between SCPD and overload relay* 17 Verification of conventional Operational performance * 18 Performance under short circuit conditions* 19 Verification of ability to withstand overload current* 20 Performance at reduced short circuit currents* 21 Conditional short Circuit current* 22 Verification of rated making and breaking capacity* 23 Verification of the Rated residual making and breaking capacity* 24 Verification of the coordination at the rated making and breaking capacity* 25 Verification of the coordination at rated conditional residual short circuit current* 26 Verification of the coordination at rated conditional residual short circuit current*

7 L V Switchgear and Control gear Sheet 7 of Short circuit Performance at IS/IEC , Range - 100kA for 3 secs. l500a IS/IEC , 550V, 80 ka for 3 secs. 726V 28 Service short circuit capacity IS/IEC , IS/IEC , 29 Performance at rated short IS/IEC , circuit capacity* lec , 30 Circuit fault current test* lec , 31 Rated earth fault breaking lec , current test* lec , 32 Flexible cord test* lec , lec , 33 Temperature rise verification Upto 25 ka, 3 ph. With lec , lec , driving voltage of 40V 34 Dielectric properties IS/IEC , Upto 100kV class. 35 Leakage current IS/IEC , 1000V, 0 to 10 A. 36 Strength of actuator lec , 18 gms to kgms. mechanism IEC: , 37 Operational performance* IS (Part-I), Tripping limits and IS (Part-2), Upto 100kA. characteristics IS3427,/IEC: Mechanical operation and lec , Upto 100kA, 1000Volts Class. operational performance lec , capability lec , 40 Overload performance* lec , Upto 100kA. 41 Verification of Overload lec , releases lec , 42 Marking dimensions, IS 10027, visual examination, lec 60755, General IS 13032, lec /0, 43 Mechanism/Trip free IS 14659, mechanism lec 60466, 44 Indelibility of marking IS 9000(Part-VIII) 45 Clearances and creepage distances 46 Non Interchangeability cNm, 1-6Nm, Nm 47 Reliability of screws, current carrying parts and connectors 48 Reliability of terminals for 50N-100N, cNm, 1-6Nm external conductors Nm 49 Protection against electric shock 50 Resistance to heat 51 Resistance to abnormal heat and to fire 52 Resistance to rusting day testing 54 Mechanical and electrical* endurance test 55 Trip and non trip test 56 Resistance to mechanical shock and impact 57 Voltage drop/effective 0-100A, 50 V earthing 58 Environment test -10 C to 100 C, 20% to 98% RH 59 Moisture and humidity test -10 C to 100 C, 20% to 98% RH 60 Verification of operation Upto 1000V class. and operating limits 61 Verification of ability to Upto 10,000Amps. withstand overload currents 62 Verification of mechanical Upto 1000Volts. properties of terminals 63 Vibration test Upto 510 kg-f. 64 Time current characteristics* 65 Insulation resistance Upto 2000 M at 500V

8 L V Switchgear and Control gear 23 Single phase, Three phase, Energy meters and tri-vector meters 66 Transformer (current) IS/IEC , 0-100A, 50V balance test IS/IEC , IS/IEC , 67 Test for determination of IS/IEC , 0-30 A test device ampere turns IS/IEC , 68 Test for sensitivity lec , 100Amps, 300mAmps 69 Shock test lec , 100Amps, 300mAmps 70 Verification of lec , 100Amps, 300mAmps performance of test lec , device lec , lec , 71 Degree of protection lec , IP 1Xto6X&IPX1 tox6 72 Lightning Impulse lec , 35kV peak 73 HV test IS/IEC , 100kV 74 Over current device IS/IEC , -- calibration test* lec , 75 Operation of the test IEC: , -- device at the limits of IS (Part-I), rated voltage* IS (Part-2), 76 Behaviour of the RCCB in IS3427,/IEC:298 Upto 100A, 300mAmps case of failure of the line lec , voltage lec , 77 Limiting values of the non lec , Upto 100A, 300mAmps lec , operating currents under lec , overcurrent conditions lec , 78 Resistance against IS 10027, Upto 100A, 300mAmps unwanted tripping due to lec 60755, current surges IS 13032, 79 Resistance of the lec /0, Upto 100A, 300mAmps. insulation against impulse IS 14659, voltage lec 60466, 80 Behaviour of RCCB in IS 9000(Part-VIII) case of earth fault current Upto 100A, 300mAmps. comprising a d.c. component 81 Reliability Upto 100A, 300mAmps. 82 Ageing of electronic Upto 100A, 300mAmps. Component 83 Controls, Sequence Upto 100A, 300mAmps. and limits of operation 84 Residual operating Upto 100A, 300mAmps. characteristics 1 Impulse voltage test S 13779, 250 V to 10 kvp IS 13010, IEC , IEC IEC IEC IEC CBIP report 88 CBIP Manual No 304, IS 14697, Sheet 8 of 10

9 Single phase, Three phase, Energy meters and tri-vector meters Sheet 9 of 10 2 AC voltage test S 13779, Upto 5 kv 3 Insulation test IS 13010, Upto 2000 M 4 Test on limits of errors* IEC , + Current : 1.2mA to 120A 5 Interpretation of test IEC Voltage : 40 to 480V results IEC Test of meter constant* IEC Test of starting condition, IEC initial start up of the CBIP report 88 meter CBIP Manual No 304, 8 Test of no load condition IS 14697, 9 Ambient temp. influence+ 10 Test of repeatability of error+limits of error due to influence quantities+ 11 Voltage variation+ 12 Frequency variation+ 13 Reversed phase sequence+ 14 Voltage unbalance+ 15 DC & even harmonics in current circuit+ 16 Continuousmagnetic induction of external origin + 17 Magnetic induction of external origin + 18 Stray d.c.magnetic induction of external origin + 19 Abnormal d.c.magnetic Induction of external origin+ 20 Stray a.c.magnetic induction of external origin+ 21 Abnormal a.c.magnetic Induction of external Origin (10 mt) + 22 Abnormal a.c.magnetic induction (0.2T) + 23 Test of Power Consumption 24 Influence of supply voltage+ 25 Short time over current Test+ 26 Influence of self heating+ 27 Influence of heating+ 28 Test of immunity to Earth/phase fault + 29 Fast transient burst test 250 V to 4.4 kv 30 Electrostatic discharge Contact discharge: 10 kv Air discharge: 15 kv 31 Dry heat test Upto 75 C 32 Cold test Upto -25 C 33 Damp heat cyclic test RH 30% to 98%, -25 C to 75 C 34 Spring Hammer Test/ 0.22Nm mechanical test of meter case 35 Protection against penetration of dust and water 36 Test of resistance to heat & fire 37 Auxiliary voltage 15% + 38 Phase of auxiliary Supply changed by 120 +

10 Single phase, Three phase, Energy meters and tri-vector meters 39 Range of adjustment. + IS 13779, 40 Independence of IS 13010, adjustment. + IEC , 41 Sustained accuracy test+ IEC Oblique suspension. + IEC Mechanical load of either IEC single or multirate IEC Resister + CBIP report Test on material used in CBIP Manual No 304, dial + IS 14697, 45 Running at low load Magnetic field of an Accessories + 46 General, meter case, window, Terminals, terminal cover, Protective earth terminal. Clearance & creepage distances, Insulating encased meter, Display of measured values, output device All ratings All ratings Sheet 10 of Marking of meters 48 Register( counting mechanism) 49 Direction of rotation & marking of the rotor, Speed of Rotation 50 Radio Interference 9.0 khz to 2 GHz measurement 51 Test of Immunity to 10 khz to 3 GHz electromagnetic HF Fields. 52 Test of immunity to 150 khz to 250 MHz conducted disturbances induced by Radio frequency field. 53 Vibration test Sign and random 0.1 Hzto 3.5 khz 54 Shock test Half sign 55 Physical communication interface 56 Communication requirement 57 System level test + 58 Operation of an Accessories + 59 Waveform 10% of 1 st to 10 th harmonics harmonic in the current+ 60 Harmonic component in 1 st to 10 th harmonics current and voltage circuit + 61 Sub harmonic in ac 1 st to 10 th harmonics current circuit 62 Odd harmonics in ac current circuit* 63 Surge immunity test 200 V to 6.0 kv 64 Damped oscillatory wave 200 V to 4.0 kv immunity 65 Verification of antitamper features * CPRI document TOP-04 1mA to 120 A 40 to 480V

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS (PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Circulating Current Relay. Type IRXm

Circulating Current Relay. Type IRXm Circulating Current Relay Type IRXm ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering

More information

Instrument Transformers Application Guide

Instrument Transformers Application Guide Instrument Transformers Application Guide Edited by ABB AB High Voltage Products Department: Marketing & Sales Text: Knut Sjövall, ABB Layout, 3D and images: Mats Findell, ABB SE-771 80 LUDVIKA, Sweden

More information

www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy. s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

NMI M 6-2 Electricity Meters. Part 2: Test Report Format NMI M 6-2 Electricity Meters Part 2: Test Report Format Commonwealth of Australia 2010 First edition September 2010 National Measurement Institute Bradfield Road, Lindfield, NSW 2070 PO Box 264, Lindfield,

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Trip circuit supervision relay. Type RXTCS

Trip circuit supervision relay. Type RXTCS Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012 TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets 17th April 2012 Session 2 Technological challenges to cope with in TWENTIES field tests

More information

Line Reactors and AC Drives

Line Reactors and AC Drives Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H. POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Residual Current Circuit Breaker

Residual Current Circuit Breaker Introduction Residual Current Circuit Breaker / ELCB The Fault current overloads and short circuits can be detected by circuit breakers like MCB s MCCB s & HRC Fuses etc. But, Circuit breakers don t detect

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

CAPACITOR BANK TESTING SWP

CAPACITOR BANK TESTING SWP 1. PURPOSE AND SCOPE The purpose of this Standard Work Practice (SWP) is to standardise and prescribe the method for testing Capacitor Banks including capacitors, tuning reactors and inrush limiting reactors.

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under: REQUIREMENT : The equipment offered shall be highly reliable suitable to operate satisfactorily in hot humid and polluted climate. The equipments offered shall work satisfactorily within temperature range

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

How To Understand The Electrical Power Supply Of A Power Supply System

How To Understand The Electrical Power Supply Of A Power Supply System 17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on

More information

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

3) What is the difference between Insulating, Isolating, and Shielded Winding transformers? Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 1) What is a transformer and how does it work? A transformer

More information

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear. OVERCURRENT & EARTH FAULT RELAYS Objective: To study the protection of equipment and system by relays in conjunction with switchgear. Theory: The function of a relay is to detect abnormal conditions in

More information

GUIDE FOR TESTING POWER TRANSFORMERS

GUIDE FOR TESTING POWER TRANSFORMERS GUIDE FOR TESTING POWER TRANSFORMERS Routine test 11/11/02 Pagina 1 di 10 INDEX Introduction... 3 1 Dielectric tests Separate-source voltage withstand test... 4 2 Induced voltage test... 5 3 Voltage ratio

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

The complete range of consumer switchboards and switchgear

The complete range of consumer switchboards and switchgear Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial

More information

User's Guide. True RMS Industrial Multimeter

User's Guide. True RMS Industrial Multimeter User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only ATTACHMENT F CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 20 KW BUT LESS THAN OR EQUAL TO 150 KW Also Serves as Application for Category

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

HIGH VOLTAGE SHORE CONNECTION

HIGH VOLTAGE SHORE CONNECTION Guide for High Voltage Shore Connection GUIDE FOR HIGH VOLTAGE SHORE CONNECTION NOVEMBER 2011 American Bureau of Shipping Incorporated by Act of Legislature of the State of New York 1862 Copyright 2011

More information

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Medium voltage circuit breaker

Medium voltage circuit breaker Medium voltage circuit breaker IEC 60 056 and ANSI C37-06 define on one hand the operating conditions, the rated characteristics, the design and the manufacture; and on the other hand the testing, the

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Electrical Predictive and Preventative Maintenance

Electrical Predictive and Preventative Maintenance Electrical Predictive and Preventative Maintenance Electrical and mechanical equipment is subject to failure at the worst possible time for no apparent reason. - Mose Ramieh III There are two types

More information

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before

More information

FAQs-Main switchboard design criteria

FAQs-Main switchboard design criteria FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard

More information

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) Fig1. CPTR SMART CONTROL PRECISION CUSTOMIZED MANUAL OR AUTO SCR OR DIODE DRY TYPE SWITCH MODE DRY TYPE SCR OR DIODE OIL TYPE 1 INDEX PAGE 1. Cover 2. Index

More information

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS TR TSY 000757 GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS 1. Introduction.... 1.1 Purpose and Scope 1.2 Organization.. 1.3 Reason for Reissue From Technical Advisory

More information

Power transformers. Special transformers Railway

Power transformers. Special transformers Railway Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA Discussion on Class I & II Terminology IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA What is Class I & II? C57.12.00 2010 is the only document we have that defined these terms. 5.10 Insulation

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast. METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component

More information

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation 2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation 123 kv Inductive Fingrid (Finland). 18 Instrument transformers igh voltage INTRODUCTION Inductive voltage transformers are designed

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer 168-08 TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE APPARATUS A three-phase outdoor oil-immersed distribution transformer DESIGNATION 1000 kva SERIAL No. 1-08-112-01-0001 Rated power Rated voltage

More information

Power Quality Standards for Electric Service

Power Quality Standards for Electric Service Power Quality Standards for Electric Service Effective June 1, 2008 A transition period will exist from June 1 through December 31, 2008 in which installations may be approved and connected as long as

More information

Transformer Design & Design Parameters

Transformer Design & Design Parameters Transformer Design & Design Parameters - Ronnie Minhaz, P.Eng. Power Transmission + Distribution GENERATION TRANSMISSION SUB-TRANSMISSION DISTRIBUTION DISTRIBUTED POWER 115/10 or 20 kv 500/230 230/13.8

More information

ELDAŞ Elektrik Elektronik Sanayi ve Tic.A.Ş.

ELDAŞ Elektrik Elektronik Sanayi ve Tic.A.Ş. Page: 2/91 Sincan 06935 - ANKARA /TURKEY CONTENTS Page No: Contents: 2-3 Test Standards: 4 List of Test Equipment: 5 Short Description of EUT: 6 Inspection Checklist 7-8 Percentage Error Limits Test (Active)

More information

ekorrp PROTECTION, METERING AND CONTROL UNITS

ekorrp PROTECTION, METERING AND CONTROL UNITS General Instructions PROTECTION, METERING AND CONTROL UNITS LIB Transformer Substations Secondary Distribution Switchgear Primary Distribution Switchgear Protection and Automation Low Voltage Boards Distribution

More information

A Practical Guide to Dielectric Testing

A Practical Guide to Dielectric Testing Chroma Systems Solutions, Inc. A Practical Guide to Dielectric Testing 19032 Series Electrical Safety Analyzer & 19050 Series Hipot Tester AC/DC/IR/SCAN Keywords: Dielectric tests, insulation resistance

More information

Capacitor Protection Relay SPAJ 160 C. Product Guide

Capacitor Protection Relay SPAJ 160 C. Product Guide Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features One-, two- and three-phase overload stage with definite time characteristic One-, two- and three-phase

More information

VOLTAGE REGULATOR AND PARALLEL OPERATION

VOLTAGE REGULATOR AND PARALLEL OPERATION VOLTAGE REGULATOR AND PARALLEL OPERATION Generator sets are operated in parallel to improve fuel economy and reliability of the power supply. Economy is improved with multiple paralleled generators by

More information

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV 1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled

More information

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Relion 605 series. Self-powered feeder protection REJ603 Product Guide Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1.... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...

More information

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques Howard W. Penrose, Ph.D On behalf of ALL-TEST Pro, LLC Old Saybrook, CT Introduction Field and shop testing of

More information

Enhanced Quality with a Touch of Style

Enhanced Quality with a Touch of Style Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility

More information

Power Quality for Information Technology System

Power Quality for Information Technology System Power Quality for Information Technology System ITS OBVIOUS THE TOLERANCE IS DIFFRENT But What isn t Tobvious? HOW MANY OF YOU HAVE : A COMPUTER AT HOME? = Computers are not screens and Keyboards COMPUTERS

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

World Leader in HV Testing Technology

World Leader in HV Testing Technology World Leader in HV Testing Technology Cable Fault Locators w/tdr Oil/Fluid Dielectric Testers Very Low Frequency AC Technology W/TD & PD Diagnostics Portable AC Hipots ---------------------------------

More information

Arc Terminator Active Arc-Resistant Switchgear

Arc Terminator Active Arc-Resistant Switchgear Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers

More information

Presentation of the France Transfo factories

Presentation of the France Transfo factories Presentation of the France Transfo factories France Transfo's internationally recognised and highly esteemed expertise is today exported to more than 80 countries throughout the world. Over the past 15

More information