Rules for Classification and Construction Additional Rules and Guidelines
|
|
|
- Flora Daniel
- 9 years ago
- Views:
Transcription
1 VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 6 Test Requirements for Electrical Machinery Edition 1999
2 The following Guidelines come into force on October1 st, "General Terms and Conditions" of the respective latest edition will be applicable (see Rules for Classification and Construction, I Ship Technology, Part 0 Classification and Surveys). Reproduction by printing or photostatic means is only permissible with the consent of Germanischer Lloyd. Germanischer Lloyd AG Head Office Vorsetzen 35, Hamburg / Germany Telefon Telefax [email protected] Published by: Germanischer Lloyd AG, Hamburg Printed by: Gebrüder Braasch GmbH, Hamburg
3 VI - Part 7 Table of Contents Chapter 6 Page 3 Table of Contents Section 1 General Requirements A. Scope B. Reference to other Rules and Regulations C. Obligation to perform Type Tests D. Documentation to be submitted E. Product Requirements Section 2 Test Requirements A. General B. Testings C. Table of Tests to be performed
4
5 VI - Part 7 Section 1 E General Requirements Chapter 6 Page 1 1 Section 1 General Requirements A. Scope The present Regulations apply to type testing of electrical machinery. 2. If manufacturers intend to test electrical machinery on their own responsibility, apart from compliance with other requirements type testing is conditional. B. Reference to other Rules and Regulations 1. The present Regulations have been prepared on the basis of IEC publications 34 and and/or EN (VDE 0530). 2. The following publications of Germanischer Lloyd () are applicable in conjunction with the present Regulations: Rules for Classification and Construction, I, Part 1, Chapter 3 "Electrical Installations" Regulations for the Performance of Type Tests, Part 0, Procedure Test Requirements for Electrical / Electronic Equipment, Computers and Peripherals, Part Standards other than those quoted in 1. above may be acceptable, provided they are equivalent. D. Documentation to be submitted The documentation to be submitted corresponds to that quoted in the Regulations for the Performance of Type Tests, Part 0 - Procedure, Section 3.B: Description of the electrical machinery and relevant production processes (product specification) Relevant design documentation Wiring schemes Data sheets Specification, data sheets and wiring schemes of any automatic voltage regulators and additional elements fitted Description of envisaged use Description of quality management system (QM Manual) reserve the right of demanding additional documentation to be submitted, where necessary. C. Obligation to perform Type Tests 1. Subject to the Rules for Classification and Construction of electrical machinery is not required to be type tested. However, on application electrical machinery may be type tested. E. Product Requirements The product requirements regarding design, choice of materials, functions and operating conditions are laid down in the applicable Construction Rules and other applicable Regulations.
6
7 VI - Part 7 Section 2 B Test Requirements Chapter 6 Page 2 1 Section 2 Test Requirements A. General 1. Choice of test specimens Where products are mass-produced, the test specimen is to be taken from the current production. The choice is to be agreed with. If the test specimens are prototypes, reserve the right of later on testing mass products, for the sake of comparison. Where series are concerned, representative samples may be chosen for type testing. 2. Scope of testing The scope of testing required for a type test will be defined by from case to case, depending on the product and its purpose. reserve the right of stipulating supplementary testings, where this is deemed necessary. 3. Testing sequence The testing sequence is not strictly defined, but should be fixed by manufacturer and agreed with prior to commencement of the testings. All tests stipulated for a particular product are to be carried out at one test specimen and/or, where massproduced products are concerned, at the respective specimens chosen. Any deviations from this procedure require to be agreed to by. 4. Documentation The tests performed are to be documented in test protocols, clearly and unmistakably. The measuring and testing instruments employed as well as the test methods applied are to be indicated. B. Testings 1. Visual inspection and completeness test, checking of technical documentation 1.1 Procedure The test specimen will be checked for compliance of its electrical and mechanical properties with the Construction Rules and Regulations manufacturers' specifications the construction plans, computations and wiring schemes the standards quoted. Visual inspection will take place prior to commencement of a type test and may have to be repeated following each test phase, such as to ascertain any visible defects at the test specimen. 1.2 Result The test is regarded to have been passed, if the test specimen meets the requirements of the Construction Rules and Regulations and complies with the specification requirements and the documentation and does not show any defects. 2. Control of function of accessories and supplementary elements 2.1 Procedure The accessories and supplementary elements (e.g. space heaters, temperature detectors, voltage and current transformers, external ventilators) will be function-tested. 2.2 Result The test is regarded to have been passed, if construction and function meet the requirements. 3. Measurement of air gaps 3.1 Procedure The air gaps of the machinery and, possibly, exciter machines installed are to be measured. 3.2 Result The measurement result is regarded as being adequate, if the air gaps comply with the required values within the tolerance limits. 4. Measurement of winding resistances 4.1 Procedure The winding resistances of the test specimen are to be measured at ambient temperature, using appropriate measuring instruments.
8 Chapter 6 Page 2 2 Section 2 B Test Requirements VI - Part Result The measurement result is regarded as being adequate, if the values measured and referred to 20 C comply with those calculated within the tolerance limits. 5. Measurement of short circuit characteristic 5.1 Procedure Where a.c. motors are concerned, measurements are to be conducted with the rotor being firmly braked and at constant frequency for determining the current and power consumption as a function of voltage; the starting current is to be measured. In the case of generators the current is to be measured with shortcircuited stator as a function of the excitation current. 5.2 Result The measurement result is regarded as being adequate, if the values calculated coincide to a considerable degree with those measured and if the tolerances of the values specified are not exceeded. 6. Measurement of no-load characteristic 6.1 Procedure In the case of a.c. motors measurements are to be conducted at no load at rated frequency, such as to determine the current and power consumption as a function of voltage. In the case of generators, with the stator terminals in open condition and at rated frequency the voltage is to be measured as a function of the excitation current. 6.2 Result The measurement result is regarded as being adequate, if the values calculated coincide to a considerable degree with those measured and if the tolerances of the values specified are not exceeded. 7. Measurement of the load characteristic 7.1 Procedure In the case of motors the speed is to be measured as a function of the load, and in the case of generators the voltage is to be measured as a function of the load. 7.2 Result Unless otherwise specified, the requirements of the Construction Rules are to be complied with. Induction motors must not substantially deviate from their rated speed; they must not pull out. Synchronous generators must during operation at rated power and rated power factor not exceed the voltage tolerances stated in the Construction Rules. During operation at rated speed from no-load speed up to the rated power and at the rated power factor the voltage must not deviate from the rated voltage by more than +/- 2.5 % (in the case of emergency generating sets +/- 3.5 %), once the transient compensation processes have been terminated. 8. Overload capability test 8.1 Procedure Proof of overload capability of the machinery is to be furnished: for a.c. generators: 1.5 I rated for 2 minutes, cos phi 0.5 inductive (lagging), with the generator voltage being kept approximately constant. for motors: 1.6 M rated torque for 15 seconds for motors for anchor windlasses: 2 M rated torque for 2 minutes Induction motors must not pull out. 8.2 Result Unless stricter specifications exist, compliance with the requirements quoted in 8.1 is to be proved. 9. Test at decreased/increased voltage and frequency 9.1 Procedure Proof is to be furnished of operability both at decreased and increased voltage frequency. 9.2 Result The test is regarded to have been passed, if operability is safeguarded at the specified voltage and frequency limit values. 10. Determination of starting and breakdown torque 10.1 Procedure For a.c. motors the starting and breakdown torque is to be determined Result The torques measured are to be within the tolerance limits as per VDE / IEC. 11. Load thrown on and off, checking of AVR 11.1 Procedure For generating sets the time behaviour of the voltage with load thrown on and off is to be oscillographed.
9 VI - Part 7 Section 2 B Test Requirements Chapter 6 Page 2 3 During operation of the generator at rated speed and rated voltage the voltage must not be less than 85 % of the rated voltage nor exceed 120 %, if suddenly the load is symmetrically thrown on or off, at a current and power factor to be specified. The generator voltage has to be constant within 1.5 sec. at U rated +/- 3 % (in the case of emergency generators +/- 4 %). Unless any specific details on load variations are available, the requirements listed above are to be met, if the generator in no-load condition and excited to rated voltage is suddenly loaded to 60 % of its rated current and a power factor < 0.4 (lagging) and suddenly unloaded again, after the steady conditions have been achieved Result Unless stricter specifications exist, compliance with the requirements quoted in 11.1 is to be proved. 12. Measurement of the rotor voltage 12.1 Procedure For slip-ring motors the rotor voltage is to be measured Result Compliance of the values calculated with those measured must be given. 13. Winding test 13.1 Procedure Under certain conditions, e.g. where doubts exist as to the insulation strength, a winding test is to be carried out Result The test specimen must be capable of resisting the increased voltage without damage during the period stipulated. 14. Overspeed test 14.1 Procedure For proof of mechanical strength a test is to be carried out at increased speed in line with the Construction Rule requirements Result The machinery is to be designed such as to be capable of resisting the overspeed during the period stated in the Construction Rules. The test is regarded as having been passed, if no permanent detrimental deformations or other deficiencies interfering with the normal operation of the machine occur. 15. Measurement of wave form 15.1 Procedure For generators the wave form is to be recorded by oscillograph and possibly analysed Result At no moment must the wave form of the interlinked no-load voltage deviate from the sinusoidal fundamental wave form by more than 5 %, related to the peak value of the first harmonic. 16. Vibration test 16.1 Procedure The vibration behaviour of the machine is to be measured at no-load and full load and, where necessary, also as a function of speed Result The vibrations generated by the machine must not exceed the limits defined for the respective use. 17. Calculation of efficiencies 17.1 Procedure Efficiencies are to be determined for no load, part load and full load Result The efficiencies calculated must not be below the values specified. 18. Heat run test 18.1 Procedure A heat run test is to be carried out at the completely mounted machine under nominal conditions and taking into account the type of operation Result The temperature rise measured must not exceed the limit values stated in the Construction Rules, taking into account a relevant temperature reserve (normally 10 %). 19. Determination of steady short circuit current 19.1 Procedure For generators the steady short circuit current is to be measured under AVR control.
10 Chapter 6 Page 2 4 Section 2 B Test Requirements VI - Part Result The test is regarded as having been passed, if the generators and the excitation equipment are capable of conveying the steady short circuit for two seconds, without suffering any damage. Unless otherwise specified, the steady short circuit current must not be less than three times the rated current and/or exceed 6 times the rated current. 20. Sudden short circuit test 20.1 Procedure For determination of the reactances and for proof of the mechanical strength of generators, a sudden short circuit test may be stipulated Result The test is regarded as having been passed, if the sudden short circuit has not caused any visible damages and deformations and the function is still ensured. The reactances measured have to be within the tolerance range indicated for each practical case. 21. Testing of degree of protection 21.1 Procedure Subject to VDE 0530 T5 / IEC 34-5 the degree of protection is to be tested Result The test is regarded as having been passed, if the requirements of the referenced standards are complied with. 22. Vibration test 22.1 Procedure The test method and test conditions are defined in the Regulations for the Performance of Type Tests, Part Test for EMC 25.1 Procedure The procedures outlined in the Regulations for the Performance of Type Tests, Part 1 are to be applied. The scope of testing will be agreed between and manufacturers, depending on the respective use Result The test is regarded as having been passed, if neither any damages nor permanent or temporary operational disturbances have occurred. The test serves the purpose of furnishing proof that under the effect of induced vibrations (curve 1, excitation 0.7 g) the test specimen does not show any damages or temporary or permanent operational disturbances Result The test is regarded as having been passed, if the specified functions have been proved and if no damages or operational disturbances have been found at the test specimen. 23. Damp heat test 23.1 Procedure The test is to be conducted in accordance with the procedure outlined in the Regulations for the Performance of Type Tests, Part Result The test is regarded as having been passed, if under the effect of damp heat neither any damages nor permanent or temporary operational disturbances have occurred. 24. Salt mist test 24.1 Procedure The test is to be carried out only at machinery intended to be installed on the open deck. The procedure defined in the Regulations for the Performance of Type Tests, Part 1 is to be applied Result The test is regarded as having been passed, if under the effect of salt mist the test specimen does not show any damages to components (corrosion) or any negative effects upon its operability. 26. High-voltage test 26.1 Procedure Upon completion of other tests (except for 27.) the windings are to be subjected to a high-voltage test at the voltages quoted in the Construction Rules. Where practicable, the test is to be carried out with the machine in warm-running condition. The non-tested windings are to be grounded.
11 VI - Part 7 Section 2 B Test Requirements Chapter 6 Page Result The high-voltage test is regarded as being passed, if each winding has resisted undamaged the test voltage as stipulated in the Construction Rules during the period indicated. 27. Measurement of insulation resistances 27.1 Procedure The last test to be carried out consists in measuring the insulation resistance of each winding and of all auxiliary and supplementary elements against earth, where practicable with the machine in warm-running condition. The non-tested windings and elements are to be grounded Result The insulation resistance of each winding and of the supplementary elements must not fall short of the values stated in the Construction Rules. Subject to Section 3.2 the scope of testing is fixed by in each individual case, depending on the product and scope of testing. The following table shows normal test range.
12 Chapter 6 Page 2 6 Section 2 C Test Requirements VI - Part 7 C. Table of Tests to be performed Table 2.1 Curr. No. Test D.C. motor Induction-motor Synchronous generator 1 Visual inspection and completeness test 2 Control of function of supplement elements 3 Measurement of airgaps 4 Measurement of winding resistances 5 Short circuit characteristic 6 No-load characteristic 7 Load characteristic 8 Overload test 9 Test at decreased / increased voltage / frequency 10 Determination of starting and breakdown torque 11 Load thrown on and off 12 Measurement of rotor voltage 1 13 Winding test 14 Overspeed test 2 15 Waveformtest 16 Vibration test 17 Calculation of efficienties 18 Heatrun test 19 Determination of steady short circuit current 20 Sudden short circuit test 21 Test of degree of protection 22 Vibration test 23 Damp heat test 24 Salt mist test Tests of EMC capability 26 High voltage test 27 Measurement of insulation resistances Test required to be performed 1 For slip-ring motors only 2 May be dispensed with for sqirrel-cage induction motors 3 To be performed only for machines used on the open deck
REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
Rules for Classification and Construction Ship Technology
I Rules for Classification and Construction Ship Technology 1 Seagoing Ships 19 Guidelines for the Carriage of Refrigerated Containers on Board Ships Edition 2003 The following Guidelines come into force
PM734F - Technical Data Sheet Winding 28
- Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including
PI734D - Technical Data Sheet
PI734D - Technical Data Sheet PI734D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
PI734B - Technical Data Sheet
PI734B - Technical Data Sheet PI734B SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
HCM434F - Winding 311 Technical Data Sheet HCM434F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards
PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS
PI144K - Winding 311 Technical Data Sheet PI144K SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section
PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
PI044E - Winding 311 Technical Data Sheet PI044E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
UCI274C - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,
UCI274H - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.
Lab 9: Synchronous motor. Objective: to examine the design of a 3-phase synchronous motor; to learn how to connect it; to obtain its starting characteristic; to determine the full-load characteristic of
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
BCI184E - Technical Data Sheet
BCI184E - Technical Data Sheet BCI184E SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
DNVGL-CP-0393 Edition December 2015
CLASS PROGRAMME Type approval DNVGL-CP-0393 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations
VI Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations 5 Guidelines for Design, Equipment and Testing of Gas Welding Installations on Seagoing Ships Edition
Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts
Product Specification 108-19346 17 APR 2013 Rev F Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts 1. SCOPE 1.1. Content NOTE The product may not perform according
Motor Fundamentals. DC Motor
Motor Fundamentals Before we can examine the function of a drive, we must understand the basic operation of the motor. It is used to convert the electrical energy, supplied by the controller, to mechanical
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
8 Speed control of Induction Machines
8 Speed control of Induction Machines We have seen the speed torque characteristic of the machine. In the stable region of operation in the motoring mode, the curve is rather steep and goes from zero torque
FREQUENCY CONTROLLED AC MOTOR DRIVE
FREQUENCY CONTROLLED AC MOTOR DRIVE 1.0 Features of Standard AC Motors The squirrel cage induction motor is the electrical motor motor type most widely used in industry. This leading position results mainly
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer
168-08 TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE APPARATUS A three-phase outdoor oil-immersed distribution transformer DESIGNATION 1000 kva SERIAL No. 1-08-112-01-0001 Rated power Rated voltage
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
SINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO 250447392
1 Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading By Ramandeep Kaur Aujla S.NO 250447392 ES 586b: Theory and applications of protective relays Department of
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR
1 DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING Constructional details Types of rotors EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR PART A 1.
Rules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 2 Test Requirements for Electrical / Electronic Equipment and Systems Edition
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
Offshore Platform Powered With New Electrical Motor Drive System
Offshore Platform Powered With New Electrical Motor Drive System Authors: Jan O. Lamell, M.Sc E.E. ABB Automation Technologies Presenters: Thomas Johansson, M.Sc E.E. ABB Automation Technologies Timothy
Rules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 5 Pumps 1 Guidelines for the Design, Construction and Testing of Pumps Edition 2007 The following Guidelines come into force
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60076-1 Edition 2.1 2000-04 Edition 2:1993 consolidated with amendment 1:1999 Power transformers Part 1: General This English-language version is derived from the original bilingual
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Unit 33 Three-Phase Motors
Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation
Lab 14: 3-phase alternator.
Lab 14: 3-phase alternator. Objective: to obtain the no-load saturation curve of the alternator; to determine the voltage regulation characteristic of the alternator with resistive, capacitive, and inductive
High-ohmic/high-voltage resistors
FEATURES These resistors meet the safety requirements of: UL1676 (range 510 kω to 11 MΩ) EN60065 BS60065 (U.K.) NFC 92-130 (France) VDE 0860 (Germany) High pulse loading capability Small size. APPLICATIONS
Residual current socket 30mA Order No.: 0477..
30mA Order o.: 0477.. 1. Operating description The operating principle of the residual current socket is identical to that of the residual current device. In a fault-free installation, in which no current
ENVIRONMENTAL TEST SPECIFICA- TION FOR INSTRUMENTATION AND AUTOMATION EQUIPMENT
STANDARD FOR CERTIFICATION No. 2.4 ENVIRONMENTAL TEST SPECIFICA- TION FOR INSTRUMENTATION AND AUTOMATION EQUIPMENT APRIL 2006 FOREWORD (DNV) is an autonomous and independent foundation with the objectives
Technical Guide No. 100. High Performance Drives -- speed and torque regulation
Technical Guide No. 100 High Performance Drives -- speed and torque regulation Process Regulator Speed Regulator Torque Regulator Process Technical Guide: The illustrations, charts and examples given in
CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN
CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN 5.1 Introduction So far in the development of this research, the focus has been to estimate the available insolation at a particular location on the earth s surface
Automatic Voltage Regulator User s Manual
Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright
INTERNATIONAL STANDARD
INTENATIONAL STANDAD IEC 60034-1 Eleventh edition 2004-04 otating electrical machines Part 1: ating and performance This English-language version is derived from the original bilingual publication by leaving
AC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Power transformers. Special transformers Railway
Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together
Lab 8: DC generators: shunt, series, and compounded.
Lab 8: DC generators: shunt, series, and compounded. Objective: to study the properties of DC generators under no-load and full-load conditions; to learn how to connect these generators; to obtain their
How the efficiency of induction motor is measured?
How the efficiency of induction motor is measured? S. Corino E. Romero L.F. Mantilla Department of Electrical Engineering and Energy E.T.S.I.I. y T. Universidad de Cantabria Avda de Los Castros, 395 Santander
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power
Stepper motor I/O. Application Note DK9222-0410-0014 Motion Control. A General information on stepper motors
Stepper motor Keywords Stepper motor Fieldbus Microstepping Encoder Phase current Travel distance control Speed interface KL2531 KL2541 Part A of this Application Example provides general information on
3790 en - 06.2007 / d. Alternators LSA 46.2-4 Pole. Electrical and mechanical data
379 en - 6.7 / d Alternators LSA 46.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 46.2 alternator is designed to be suitable for typical generator applications, such
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
Rules for Classification and Construction Ship Technology
I Rules for Classification and Construction Ship Technology 1 Seagoing Ships 17 Guidelines for Machinery Condition Monitoring Edition 2008 The following Guidelines come into force on February 15 th, 2008
A S Y N C H R O N O U S M O T O R S
ASYNCHRONOUS M O T O R S S E R I E S INDAR ASYNCHRONOUS MOTORS S E R I E S WHO WE ARE Indar Electric s trajectory is endorsed by the construction of thousands of motors for the different industrial sectors.
Basics of Electricity
Basics of Electricity Generator Theory PJM State & Member Training Dept. PJM 2014 8/6/2013 Objectives The student will be able to: Describe the process of electromagnetic induction Identify the major components
IV. Three-Phase Induction Machines. Induction Machines
IV. Three-Phase Induction Machines Induction Machines 1 2 3 4 5 6 7 8 9 10 11 12 13 Example 1: A 480V, 60 Hz, 6-pole, three-phase, delta-connected induction motor has the following parameters: R 1 =0.461
DIRECT CURRENT GENERATORS
DIRECT CURRENT GENERATORS Revision 12:50 14 Nov 05 INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy by using the principle of magnetic induction. This principle
Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system
SYNCHRONOUS MACHINES Tze-Fun Chan Hong Kong Polytechnic University, Hong Kong, China Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting,
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6
Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2
IT Power Solutions CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2 Thomas B. Jones 1 Introduction Operators and managers consider outages, operational
Guideline for Energy Efficient Electrical systems for building. Presentation by TERI
Guideline for Energy Efficient Electrical systems for building Presentation by TERI Objective of study The study highlights how BBMP can implement energy efficiency measures in building in co-ordination
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA
Speed Control Methods of Various Types of Speed Control Motors Kazuya SHIRAHATA Oriental Motor Co., Ltd. offers a wide variety of speed control motors. Our speed control motor packages include the motor,
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.
SECTION 263354 STATIC UPS TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes 1. System start-up services. 2. Battery charging. 3. Load bank testing. 4. Battery load testing. 5.
13 ELECTRIC MOTORS. 13.1 Basic Relations
13 ELECTRIC MOTORS Modern underwater vehicles and surface vessels are making increased use of electrical actuators, for all range of tasks including weaponry, control surfaces, and main propulsion. This
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
Rotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.
Lab 13: Wound rotor induction motor. Objective: to examine the construction of a 3-phase wound rotor induction motor; to understand exciting current, synchronous speed and slip in this motor; to determine
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
Variable Frequency Drives - a Comparison of VSI versus LCI Systems
Variable Frequency Drives - a Comparison of VSI versus LCI Systems Introduction TMEIC is a leader in the innovative design and manufacture of large ac variable f requency drive systems. TMEIC has been
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Data Sheet. AC Industrial Electric Motors
Data Pack B Issued ovember 2005 1502325812 Data Sheet AC Industrial Electric Motors Standards organisations The RS-ABB range of ac induction motors is produced to common European standards, these being
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
WIND TURBINE TECHNOLOGY
Module 2.2-2 WIND TURBINE TECHNOLOGY Electrical System Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 2005 Nadi, Republic of the Fiji Islands Contents Module 2.2 Types of generator systems
SYNCHRONOUS MACHINES
SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical
PTC-Resistor Temperature-Sensors MINIKA to DIN 44 081 and DIN 44 082
PTC-Resistor Temperature-Sensors MINIKA to DIN 44 081 and DIN 44 082 General PTC-resistor temperature sensors (also called PTC-resistors or thermistors) are temperatur dependent semiconductor resistors
Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l
D C S e r v o S y s t e m s RH Mini Series Total Motion Control Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l Precision Gearing & Motion Control DC SERVO ACTUATORS
Siemens Generator Test Center Muelheim an der Ruhr, Germany
siemens.com/energy/generators Siemens Generator Test Center Muelheim an der Ruhr, Germany A high-performance test field with a long tradition Answers for energy. Test with the best: Siemens Test Center
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet
ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Requirements concerning ELECTRICAL INSTALLATIONS
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Requirements concerning ELECTRICAL INSTALLATIONS CONTENTS E1 Governing characteristics of generator prime movers 1975 E2 Deleted December 1996 E3 Deleted