Jonathan Sloam UK Business Manager Prysmian Cables & Systems Ltd
|
|
- Kellie Howard
- 7 years ago
- Views:
Transcription
1 Jonathan Sloam UK Business Manager Prysmian Cables & Systems Ltd
2 Innovation from manufacture to market
3 Innovation distinguishes between a leader and a follower. Steve Jobs Apple
4 The Prysmian Group (was Pirelli)
5 Prysmian operates 54 plants, has subsidiaries in 36 countries with more than 12,000 employees Pikkala Prescott Abbeville Lexington St. Jean Vila Velha St. Andrè Sorocaba Jacarei La Rosa Quilmes Abidjan Grombalia Tianjin (3) Baoying Wuxi Kuala Lumpur Cikampek Dee Why Liverpool Auckland Schwerin Eastleigh Wrexham Prescot Aberdare Bishopstoke Delft Neustadt Amfreville Angy Xoulces Vologne Balassagyarmat Gron Paron Kistelek Livorno F. Chavanoz Slatina Charvieu Merlino Quattordio Ascoli Livorno Pignataro Giovinazzo Cavimar Cavigel Arco Felice Battipaglia Fercable Mudanya
6 Our mission To be the leading player in the cable industry through Technology Innovation Service Quality for Long-term Customer Satisfaction
7 Innovative History 2008 FP600S 2007 New generation FP PLUS FP PLUS FLEX FP600 FP FIREFIX 2003 FP PLUS 2002 AFUMEX Armoured LSOH Armoured 1976 FP100 FP200 LSOH Flat Wiring Cable FP300 LSOH Conduit Wire LSX FP400 FP200 GOLD Insudite FP/T /09
8 Focus on Added Value products In the UK we make 99pc of the cables we sell in T+I market and employ >1000 people Basec and LPCB approval schemes Internal audits External audits Product check ups
9 Focus on Added Value products British Standards describe the recipe for making a cable Quality and Quantity of ingredients and size But whilst we invest in R+D, people and innovative ideas at the front end there are some really scary things going on behind the scenes that I wanted to briefly discuss today
10 Hells Kitchen? Same ingredients Different outcome What happens when one reduce the quantities or changes the quality of the ingredients
11 Faulty Cables Examined by Prysmian
12 Fake Fire Resistant Cables -1 Cable markings 2x1.5mm² sq. FIRE FLEX 300/500 VOLT BS6360 BS6387 CAT B IEC 331 BRITISH MADE CABLE Key points 1. Not fire resistant PVC insulation & PVC sheath fails within 2 mins. 2. Not compliant with any standards marked on sheath. 3. Copper coated steel conductors low conductivity not compliant. 4. Steel circuit protective conductor low conductivity not complaint. 5. Probably not British made.
13 Fake Fire Resistant Cables -2 Cable markings 2.15mm² SQ FIRE FLEX FIRE RESISTANT CABLE LPCB 682a/01 BS5839-1: d BS 6360/BS6387 CWZ BS EN PH30 300/500V BRITISH MADE CABLE Key points 1. Not fire resistant PVC insulation & polyethylene sheath. 2. Not compliant with any standards marked on sheath. 3. Copper coated aluminium conductors low conductivity not to spec. 4. Undersize circuit protective conductor also Cu coated Al. 5. Not LPCB approved uses another manufacturer s approval number. 6. Probably not British made.
14 Non-compliant PVC Artic grade Flex Cable Markings <HAR> 3183AG 1.5 SQMM BS6500 Key points 1. Undersize conductor low conductivity - ~1mm² instead of 1.5mm² 2. Cable sheath falls apart in low temperature bend test. 3. Not compliant with standard marked on sheath
15 Non-compliant Armoured cables Cable Markings ELECTRIC Grade 1100V as per BS Sqmm Key points 1. Insufficient steel wire armour conductivity wire diameter too small 2. Armour wires not sufficiently galvanised corrosion evident 3. Insufficient copper conductor conductivity more like a 25 mm² 4. Not complaint with standard marked on sheath
16 Other issues found 1. Reels marked 100 on the label with no unit of measure (although the invoice states 100m) actually measured as 100 yards. 2. BASEC label on reels although product not BASEC approved. 3. Reels marked 100m yet measure at 94m 4. Printing of erroneous info on cable/labels
17 The Problem Many of you here today have either purchased, stocked or installed some of these products! Many of you are not aware of the seriousness of the problem You cannot really tell by looking at a Cable that something s up
18 So what are we going to do about it? 1. Prysmian, along with support of all members of the British Cable Association, has come up with a strategy 2. A Strategy to Reinforce the Positioning and Selection of Approved Cables within the UK Market 3. Reinforce responsibilities of those in supply chain 4. Deliver a clear message
19 Status on Approved Cables Initiative to Date Strategy paper circulated to all key players Meetings held with Executive members of ECA, EDA, NICEIC/ESC, ENA Prysmian met with local Hampshire MP Chris Huhne that has resulted in PQ s having been raised Chris Huhne made contact with Ed Milliband (EM)
20 Communicate Educate Investigate POLICE Eradicate
21 INVESTIGATE ERADICATE Obtain samples & test them Quick response times and feedback Actions/ Punishments/ Communications Involve all supply chain in this policing not just manufacturers If do not communicate, then whole project is of little value Communications must include: a) NAC manufacturers b) NAC distributors c) HO s of wholesaler whose branches are selling NAC cable d) NICEIC, ECA, EDA, ENA Risk alert message to all members to check this product/ manufacturer/ W/S branch/ Distributor
22 BEAMA Anti-Counterfeiting Working Group Raising Awareness Poster to be issued in UK to all EDA members
23 LIABILITIES HEALTH and SAFETY AT WORK ACT. ELECTRICITY AT WORK Regulations. UNLIMITED FINE and MAXIMUM 2 YEARS IMPRISONMENT
24 LIABILITIES CONSUMER PROTECTION ACT. For CORPORATE MANSLAUGHTER Police or H&SE would prosecute UNLIMITED FINE levied on the company with a guide up to 10% of the company s annual turnover. LIFE IMPRISONMENT for any Senior Management involved in the sale of the unsafe products
25 Questions Are you aware of what you are buying and from where? Do the products comply with relevant standards? Do they do what it says on the labels?
26 Innovation on Added Value products The world is changing very fast. Big will not beat small anymore. It will be the fast beating the slow. Rupert Murdoch
27 Enhanced Fire survival cables FP600
28 Why use FP600? To meet more onerous fire survival requirements. For use in fire fighting and life safety applications Achieves maximum 120 minute fire rating to BS for fire fighting applications. Easy to install. Does not require special tools or training for installation and terminating Applications include fire protections for lifts, shutters, ventilation systems, sprinklers Alternative to MICC Lower installed cost
29 Features and benefits when using Prysmian FP Cables Unique damage resistant Insudite insulation: BENEFIT : Most F/A cables use soft easy to damage insulation which can lead to faults meaning increased time fault finding/commissioning not with FP. BENEFIT to Client: Risk (of soft insulation) not left with client in his building for whole of life building maintenance.
30 Features and benefits when using Prysmian FP Cables Easy to access Prysmian dedicated BENEFIT : Downloadable, printable pdf data sheets for O & M Manuals. BENEFIT to Client: Client can easily find and access this information also making clients systems and processes quick and simple.
31 FP FIREFIX? A fire resistant cable clip for use with FP200 Gold and FP Plus cables Alternative to AP or Saddle clip Quick and easy to install using SPIT Pulsa gas nailing tool One clip can install pair of cables
32 Why develop FP FIREFIX? Introduction of a faster, lower installed cost fixing system meeting the requirements of BS5839-1:2002 Reduced number of electricians available FP FIREFIX system means that an electrician does not need to be used for all steps of a cable installation Available in Red or White
33 Benefits Quickly fixes to various substrates: Steel + Composite steel decking Masonry + Concrete +Block work Reduces installation time and costs - up to 10 times quicker to install than conventional methods Requires no rawl plugs, drilling or screwing Can be installed before cables reducing the need to use an electrician at this stage Does not require installer to hold clip during installation improving safety when working in difficult locations
34 How it Works Attach adaptor to Pulsa 700E
35 How it Works Attach adaptor to Pulsa 700E Load nails
36 How it Works Attach adaptor to Pulsa 700E Load nails Fit clip to adaptor
37 How it Works Attach adaptor to Pulsa 700E Load nails Fit clip to adaptor Push against wall, release nail
38 How it Works Attach adaptor to Pulsa 700E Load nails Fit clip to adaptor Push against wall, release nail Insert cable(s) into clip
39 How it Works Attach adaptor to Pulsa 700E Load nails Fit clip to adaptor Push against wall, release nail Insert cable(s) into clip Close clip
40 Success? 6,0000,000 clips sold 10 times quicker to install How many hours saved? Tens of thousands hours saved 100 s of thousands GBP labour cost saved
41 Low Hazard Jointing Material JEM Health and Safety Aspects Isocyanate Free Tested to EEC Directive 96/54/EC (Methods for determination of toxicity) Skin irritation - OECD 404 Lowest order recorded Eye irritation - OECD 405 Lowest order recorded Non Flammable LSOH No special Storage or Transport
42 HV accessories 275/400kV transition joints XLPE cable FF cable 1 year load cycling test
43 HV accessories 275/400kV transition joints Connects O/F cable to Xlpe O/F cable no longer being made O/F Existing circuits can be maintained, repaired and diverted XLPE cable FF cable
44 RFID chipping Trial with Cable Drums in Utility Sector High Cost of Copper / Theft Location of drum / asset management Return / Disposal of Drum when empty Environmental Number of people involved (booking in / out) Accuracy
45 RFID chipping Current Applications Library books Airport baggage / Pallets / Containers Golf Balls Pocker Cards / Casino Chips / Theme parks Barrels of beer Animals or even People! In 2004 Conrad Chase allowed guests at his night clubs to be implanted with RFID chips. Customers who carry the chip are allowed access to the VIP area. The system also allows patrons to pay for drinks just by being scanned
46 Solution - RFID chipping
47 RFID chipping Benefits Cheap Easy IT solution Security Environmental Improved accuracy Improved supply Chain solutions Could be expanded to boxes, tools, vans, assets etc
48 Core Products - Connectivity Fibre Distribution Hub Lead-in Assembly Connectorised Lead-in Joint
49 Installation Day 1 Connect Day X Connect
50 Customer Connect (Day x) Transport Sleeve Lead-in Seal
51 Customer Connect (Day x) Transport Sleeve Lead-in seal
52 Customer Connect (Day x)
53 Customer Connect (Day x)
54 Summary The winner is the chef who takes the same ingredients as everyone else and produces the best results. Edward de Bono If you are going to buy a parachute would you buy the cheapest one?
INDUSTRY RESTRUCTURING
CABLES AND SYSTEMS MARKET TRENDS 1998-1999 CABLES ENERGY Stable volume Europe and S. America: continuous price erosion NORTH AMERICA End of monopolies Markets opening INDUSTRY RESTRUCTURING COMMUNICATIONS
More informationFIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationCTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
More informationScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
More informationLINKING THE FUTURE 2013 SUSTAINABILITY REPORT
LINKING THE FUTURE 2013 SUSTAINABILITY REPORT 2013 Sustainability Report Contents 2013 Sustainability Report 4 LETTER TO STAKEHOLDERS 6 OUR APPROACH TO SUSTAINABILITY 7 METHODOLOGY 9 PRYSMIAN GROUP 10
More informationCURRENT RATINGS MORE THAN A CABLE
CURRENT RTINGS Updated for the 17th Edition of the IEE Wiring Regulations MORE THN CBLE C O M P N Y EI CBLES, DURHM ROD, BIRTLEY, CO DURHM. DH3 2R Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail:
More informationPower and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
More information4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters
8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationNATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION
NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION NCRMI/LIB/ELE001/15 4.09.2015 Competitive sealed quotations are invited
More informationOperating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
More informationEDS 02-0027 11KV TRIPLEX CABLE
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:
More informationBlown Fibre Tube Cable Connectivity
Blown Fibre Tube Cable Connectivity Prysmian Part Numbers: See Individual Descriptions 1) Swept Tee Branching Unit 3) Extended In-Line Enclosure 2) 90 Tee Piece Branching Unit 4) 4 Port Extended In-line
More informationELECTRONIC FIRE & SECURITY SYSTEMS. Fire Detection and Alarm Systems. The FSA Short Guide Series
ELECTRONIC FIRE & Supporting the Profession to Safeguard the Client Fire & Security Association, ESCA House, 34 Palace Court, London W2 4HY T 020 7313 4888 F 020 7221 7344 E enquiries@fireandsecurityassociation.co.uk
More information3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
More informationGCSE Business Studies. Ratios. For first teaching from September 2009 For first award in Summer 2011
GCSE Business Studies Ratios For first teaching from September 2009 For first award in Summer 2011 Ratios At the end of this unit students should be able to: Interpret and analyse final accounts and balance
More informationDOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation
More informationFire safety advice for landlords
YOU CAN PREVENT IT Fire safety advice for landlords Introduction Each year there are over 50,000 fires in dwellings in the UK. These result in around 300 hundred fatalities and several thousand serious
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
More informationComprehensive safety concepts for building applications
Comprehensive safety concepts for building applications Preventive fire protection Experience, know-how, competence, quality and safety pyrofil for safety Fire reaction Dätwyler is the first european manufacturer
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationImportant Information: Complete Terms and Conditions are printed on sales invoices
Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this
More informationSession 14 Cable Support Systems
Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load
More informationGUIDE TO THE AM2 EXAM
AM2 GUIDE TO THE AM2 EXAM What is AM2? AM2 or the Achievement Measurement 2 is a practical performance skill test administered by the National Electrotechnical Training (NET). You must take the AM2 test
More informationRequirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)
Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Introduction The purpose of this document is to: 1) provide background information beneficial to specifiers
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More informationwww.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT
More informationAPPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. rohinib@ducab.com Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. Nawaf@ducab.com
More informationSCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/ 1 X C-UA- LTXLPE/2006) MAHARASHTRA STATE ELECTRICITY
More informationLANDLORDS FORUM MEETNG NOTES OF MEETING HELD ON 12 TH JUNE 2002
LANDLORDS FORUM MEETNG NOTES OF MEETING HELD ON 12 TH JUNE 2002 Introduction Marc Williams, Senior Environmental Health Officer, Wrexham County Borough Council opened the 3 rd Landlords Forum and gave
More informationCurrent Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69
Ratings TBLE BEC 107. (Continued) ratings for 60/11000 volts grade PILC/SW/PVC cable to BS64/69 CBLES LID IN IR: The ratings given in the foregoing tables are based on an ambient of C. It is recommended
More informationHARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
More information08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More information2012 ANNUAL REPORT PRYSMIAN GROUP
2012 ANNUAL REPORT PRYSMIAN GROUP CONTENTS CONTENTS CONSOLIDATED FINANCIAL STATEMENTS 7 DIRECTORS REPORT 10 Letter to stakeholders 14 Prysmian Group 30 Directors and auditors 33 Organisational structure
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationCables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationConnection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
More informationScreened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
More informationHARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationMasterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) 1268 563720. www.mkelectric.com IP66. Improved catch.
Masterseal Plus TM technical hotline +44 (0) 268 63720 Improved catch Rear drill holes Available in grey, white and black Fixed gasket speds installation gasket Now has all the features and logic plus
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationINSTALLATION ELECTRICIAN / MAINTENANCE ELECTRICIAN APPRENTICESHIP ASSESSMENT PLAN
INSTALLATION ELECTRICIAN / MAINTENANCE ELECTRICIAN APPRENTICESHIP ASSESSMENT PLAN Introduction and Overview This assessment plan is to accompany the Installation Electrician / Maintenance Electrician level
More informationT A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
More informationSCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
More informationWelded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction
Welded Fabric 1.0 Introduction Welded fabric, often referred to as mesh, is a machine welded grid arrangement of reinforcing bars or wires. It is covered by British Standard BS4483. This was revised in
More informationContents. All Rights Reserved
Electricity Specification 400C8 Issue 6 October 2015 LV Service Cables Contents 1 Scope 2 Definitions 3 General Requirements for Approvals and Assurance 4 Conditions of Installation 5 Conditions of Operation
More informationCABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
More informationNetwork Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
More informationHydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
More informationThe Electrical Control of Chemical Reactions E3-1
Experiment 3 The Electrical Control of Chemical Reactions E3-1 E3-2 The Task In this experiment you will explore the processes of oxidation and reduction, in which electrons flow between materials, and
More informationIT&T Infrastructure Standards
Technology Services IT&T Infrastructure Standards Version 1.5 17 th April 2015 Page 1 Table of contents 1 CHANGE HISTORY... 3 1.1 DOCUMENT HISTORY... 3 1.2 REVIEWERS... 3 1.3 APPROVALS... 3 2 INTRODUCTION...
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationA guide to Sage One Accounts from your accountant
SageOne Accounts A guide to Sage One Accounts from your accountant About Sage One Sage One is a series of online services for small business owners and their accountants, allowing them to manage their
More informationSTANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
More information2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G
Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements
More informationOdyssey of the Mind Technology Fair. Simple Electronics
Simple Electronics 1. Terms volts, amps, ohms, watts, positive, negative, AC, DC 2. Matching voltages a. Series vs. parallel 3. Battery capacity 4. Simple electronic circuit light bulb 5. Chose the right
More informationEVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
More informationScrew Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
More informationT H A N K S F O R A T T E N D I N G OUR. FLEX-RIGID PCBs. Presented by: Nechan Naicker
T H A N K S F O R A T T E N D I N G OUR TECHNICAL WEBINAR SERIES FLEX-RIGID PCBs Presented by: Nechan Naicker We don t just sell PCBs. We sell sleep. Cirtech EDA is the exclusive SA representative of the
More informationHow To Monitor Water Penetration In A Cable Screen
Detection and location of high voltage cable sheath damage with Water Penetration Monitoring*) Purpose of Monitoring System The expected lifetime of high voltage underground cables is more than 40 years,
More informationServices Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
More informationModel CS 64 Mini-DIN Cable and Adaptor
Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink
More informationElectrical Safety Policy
Electrical Safety Policy Version Number: V2 Name of originator/author: Director of Estates and Facilities Name of responsible committee: Estates and Facilities Committee Name of executive lead: Chief Operating
More informationTrial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time
Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to
More informationOutdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationwww.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
More information(2377) V2.0 2013 H N IO T A IC IF L A U Q
QUALIFICATION HANDBOOK Level 3 Awards in the In-Service Inspection and Testing of Electrical Equipment (PAT) and the Management Requirements for the Maintenance of Electrical Equipment (2377) V2.0 December
More informationSWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY
More informationMaking Wiring Easier Push-in Terminal Blocks for Modular Machine Designs
Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs By Gordon Busch Product Marketing Industrial Connection Technology Phoenix Contact GmbH & Co. KG Blomberg, Germany Executive Summary
More informationFlush-mount room temperature sensor AQR2531ANW.
1 408 Flush-mount room temperature sensor AQR2531... Passive sensor to acquire room temperature. Field of use 0 +50 C Use In heating, ventilation and air conditioning plants, primarily in the comfort range
More informationBETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
More informationELECSA and the Fire Industry
ELECSA and the Fire Industry Guide to Fire Protection and Fire Risk Assessment schemes www.elecsa.co.uk 80% Black 100% Black Section 1: What are the opportunities in the Fire Industry? Regulation of the
More informationElectrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
More informationIt s all about managing food. Food Recall Plan Template For Food Manufacturers
It s all about managing food. Food Recall Plan Template For Food Manufacturers What to Do In The Event Of a Product Recall Every Food Distributor and Food Manufacturer must track the products they manufacture
More informationTable of GRI indicators
2013 Sustainability Report > Table of GRI indicators Table of GRI indicators The following table of GRI-G3.1 indicators includes a brief description of each, reference to the page in the 2013 Sustainability
More informationTechnical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationRollers. from the UK s largest roller manufacturer. Quality Performance Reliability
Rollers from the UK s largest roller manufacturer Quality Performance Reliability 42 Index Gravity Rollers Light to Medium Duty 4 Heavy Duty 5 Plastic Rollers 6 Stainless Steel Rollers 7 Grooved Rollers
More informationEnterprise Telephone. Model 98390 OPERATING INSTRUCTIONS
Enterprise Telephone Model 98390 OPERATING INSTRUCTIONS This Interquartz telephone has been manufactured to very high standards and is very easy to use. Please read this manual carefully to find out how
More informationBritish Standard Underground Hydrant Range
British Standard Underground Hydrant Range 2 THE NEW AVK BRITISH STANDARD HYDRANT RANGE AVK are the renowned market leading innovators, manufacturers and suppliers of BS 750 fire hydrants into the UK,
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationOntario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
More informationDOCUMENT. Introduction WG2/01 SEPTEMBER 2012. Future CE marking requirements
GUIDANCE DOCUMENT WG2/01 SEPTEMBER 2012 SPECIFYING PERMANENT TRAFFIC SIGNS Introduction ARTSM is the trade body for companies that manufacture and supply traffic signs in the UK. Its members are committed
More informationBARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationHow to choose the very best connectors for your speaker cables and enjoy superb sound from your music system
Not all speaker plugs sound the same How to choose the very best connectors for your speaker cables and enjoy superb sound from your music system By Graham Nalty MA Not all speaker plugs sound the same
More information