FILTER TECHNICAL DATA COMPONENTS

Size: px
Start display at page:

Download "FILTER TECHNICAL DATA COMPONENTS"

Transcription

1 TR The Job of the filter is to remove any solid or liquid impurities from the air generated by the compressor. ncoming air is rotated by the centrifuge unit. The heaviest liquid and solid particles are projected against the walls of the container and forced to adhere to it. s they accumulate they form drops that deposit on the bottom by gravity. The remaining solid particles are held back by the porous element depending on the filtering threshold. The condensate accumulation area is kept still to prevent previously deposited impurities from being re-circulated. The accumulated condensate is drained out through the drain automatically when there is no pressure in the filter, or by hand pressing the button. n automatic drain is available. t automatically eliminates condensate from the container whenever necessary, whatever the pressure. TN T egree of filtration ax. input pressure Pa bar at. bar (0. Pa-9 ) ΔP 0.5 bar (0.05 Pa 7 ) at. bar (0. Pa-9 ) ΔP bar (0. Pa 4 ) luid ax temperature at Pa; 0 bar; 45 Weight Wall fixing screws ounting position rain owl capacity cm NOT ON US Kg /4 /8 /4 /8 / / /4 5 m 0 m m x anual utomatic (S) 5 m 0 m m x0 anual utomatic (S) - utomatic (R) 45 5 m 0 m m x70 anual utomatic (R) 75 The maximum inlet pressure for the version with R automatic condensate drainage must not exceed 0 bar. OPONNTS Technopolymer body Zamak end plate Technopolymer centrifuge owl: technopolymer for 00 and 00, metal for 00 Technopolymer baffle Sintered P filter cartridge Technopolymer screen lear technopolymer glass NR gaskets rain (RS) /0

2 OW RTS 00 /4 - /8 KPa bar low tests carried out at the epartment of echanics, Turin Polytechnic, using the computerized test bench following TOP RPR recommendations (SO S 58--approved) with SO 57 diaphragm gauge. () = bar - 0, Pa - 9 () = 4 bar - 0,4 Pa - 58 () = bar - 0, Pa - 87 () = 8 bar - 0,8 Pa - () = 0 bar - Pa /4 - /8 - / 00 / - /4 - KPa bar KPa bar NSONS /4 /8 /4 /8 / / / /4 /8 /4 /8 / / / hole hole hole 5./07

3 400 TR ilter with different degrees of impurity treatment and high performance: minimum load loss with changes in flow rate maximum degree of condensate separation 0 condensate level display semi-auto or auto condensate drain TN T egree of filtration ax. input pressure Pa bar at bar (0. Pa-87 ) ΔP 0.5 bar (0.05 Pa 7 ) luid ax temperature at Pa; 0 bar; 45 Weight Wall fixing screws ounting position rain owl capacity cm Notes on use Kg 400 /4 / 5 m 0 m m 5 m 0 m m x0 x0 utomatic (R) utomatic (R) Series 400 end plates come with a patented system with a rotary sliding end joint to allow the unit to be adapted to the pipe cutting distance (see page./0). The maximum inlet pressure for the version with R automatic condensate drainage must not exceed 0 bar. OPONNTS luminium body luminium end plate OT58 brass retaining ring OT58 threaded bush, axial adjustment Technopolymer centrifuge luminium bowl Sintered bronze filter cartridge luminium screen lear technopolymer glass Technopolymer plug rain (RS) NR gaskets /08

4 OW RTS 400 KPa bar low tests carried out at the epartment of echanics, Turin Polytechnic, using the computerized test bench following TOP RPR recommendations (SO S 58--approved) with SO 57 diaphragm gauge. () = bar - 0, Pa - 9 () = 4 bar - 0,4 Pa - 58 () = bar - 0, Pa - 87 () = 8 bar - 0,8 Pa - () = 0 bar - Pa KPa bar NSONS /4 / /4 / hole 78./09

5 KY TO OS 00 /4 0 m RS TR NT SZ TR PORT R O TRTON TYP O RN m 0 m 00 m /4 /8 /4 /8 / / /4 /4 / RS S RS S R* RS R RS: anual/semi-auto drain S: utomatic drain for sizes 00 and 00. Operates by depression requires variable air take-offs. R: rain for size 00 and 400. loattype operation irrespective of the pressure and flow rate. * or SK00 with R, please contact our sales assistance department ORRN OS./0 ode escription SKR 00 TR RS WTOUT N PTS S WTOUT N PTS RS WTOUT N PTS S WTOUT N PTS RS WTOUT N PTS S WTOUT N PTS /4 5 RS /4 5 S /4 0 RS /4 0 S /4 RS /4 S /8 5 RS /8 5 S /8 0 RS /8 0 S /8 RS /8 S SKR 00 TR RS WTOUT N PTS S WTOUT N PTS RS WTOUT N PTS S WTOUT N PTS RS WTOUT N PTS S WTOUT N PTS /4 5 RS /4 5 S /4 0 RS /4 0 S /4 RS /4 S /8 5 RS /8 5 S /8 0 RS /8 0 S /8 RS /8 S / 5 RS / 5 S / 0 RS / 0 S / RS / S ode escription SKR 00 TR RS WTOUT N PTS RS WTOUT N PTS RS WTOUT N PTS R WTOUT N PTS R WTOUT N PTS R WTOUT N PTS / 5 RS / 0 RS / RS / 5 R / 0 R / R /4 5 RS /4 0 RS /4 RS /4 5 R /4 0 R /4 R RS RS RS R R R ode escription SKR 400 TR RS WTOUT N PTS RS WTOUT N PTS RS WTOUT N PTS R WTOUT N PTS R WTOUT N PTS R WTOUT N PTS RS RS RS R R R /4 5 RS /4 0 RS /4 RS /4 5 R /4 0 R /4 R / 5 RS / 0 RS / RS / 5 R / 0 R / R RS RS RS R R R

REGULATORS TECHNICAL DATA COMPONENTS

REGULATORS TECHNICAL DATA COMPONENTS RUTORS ach system served by the air supply mains (e.g. actuators and general appliances) requires its own constant operating pressure. t is necessary to use a regulator to regulate the pressure within

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8 to 1-1/2 port sizes Section 12 Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes B7 Miniature eneral Purpose Filter/Regulator 1/8" and 1/" ports...................................le-12-2

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

Port Size M5 1 Rc Autodrain available New super efficient 5µm Poly-element Quick release bowl guard on some sizes High flow

Port Size M5 1 Rc Autodrain available New super efficient 5µm Poly-element Quick release bowl guard on some sizes High flow A IR PREPARATION 5.7 A IR FILTER SERIES AF AF000 2000 Port Size M5 Rc Autodrain available New super efficient 5µm Poly-element Quick release bowl guard on some sizes High flow Model AF000 AF2000 AF000

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake

More information

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Double-Headed Screw 1. 3/4 FIP x 3/4 MIP x 1/4 hole 2. 3/4 Fip x 3/4 MIP. Feed Water Connector 1. 1/2 FIP x 1/2 MIP x 1/4 OD 2. 3. Picture Item No. Description RO- 0010 Brass Water Feed 1. 3/4" FIP with 1/4" hole 2. Using on R.O. tank RO- O020 Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP RO- 0030 Brass

More information

Accumulators and Receivers

Accumulators and Receivers aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Accumulators and Receivers Catalog C-1, October 2007 Page 2 / Catalog

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...

More information

Dryaire Desiccant System

Dryaire Desiccant System Instructions/Parts Dryaire Desiccant System 310595F Model 6760 Maximum Operating Pressure: 160 PSI (1.1 MPa, 11 bar) System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

CYLINDER SERIES ISO 15552 (EX ISO 6431), Ø 32-63 mm TWO-FLAT

CYLINDER SERIES ISO 15552 (EX ISO 6431), Ø 32-63 mm TWO-FLAT YIR SRIS ISO 2 (X ISO 3), - mm TWO-T This version of cylinder is used to keep the parts fixed to the piston rod at an angle and to apply torques within the specified limits. The piston rod of the Two lat

More information

Technical Data Sheet Page 1 of 5

Technical Data Sheet Page 1 of 5 Technical ata Sheet Page of Ultra-ilter 00-00 ilter with conometer/ conomizer and pneumatic/ electronic drain resp. plug for application of different types for the industrial processing of compressed air

More information

Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (Adsorbing) Filters, and Compressed Air Membrane Dryers

Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (Adsorbing) Filters, and Compressed Air Membrane Dryers Filter Contents Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (dsorbing) Filters, and Compressed ir Membrane Dryers Filter Overview..............................LE-Filter

More information

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05 SIGMA PUMPY HRANICE SELF PRIMING PUMPS SVA SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +40 581 661 111, fax: +40 581 60 587 Email: sigmahra@sigmahra.cz 46.98 16.05 Applications

More information

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06 SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz

More information

Basic Hydraulics and Pneumatics

Basic Hydraulics and Pneumatics Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:

More information

Watts Pure Water Systems

Watts Pure Water Systems Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before

More information

In-Line Filters and Coalescers with Automatic Drains

In-Line Filters and Coalescers with Automatic Drains Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Filter Aid Filtration

Filter Aid Filtration Filter Aid Filtration Filtration is the separation of solids from liquids by forcing the liquid to flow through a porous medium and depositing the solids on the medium. A filter aid (finely divided material

More information

Filter Housing SG Standard

Filter Housing SG Standard Page of 7 Filter Housing SG Standard The steel standard filter housings with econometer and pneumatic drain are designed for the purification of compressed air and gases. Due to the modular design of the

More information

HELPFUL HINTS ON PREPARING COMPRESSED AIR

HELPFUL HINTS ON PREPARING COMPRESSED AIR HELPFUL HINTS ON PREPARING COMPRESSED AIR Introduction An efficient compressed air system does not just happen, it is the product of good planning to insure minimum pressure loss in the distribution system

More information

Modular/F.R.L. Units

Modular/F.R.L. Units odular/.r.l. nits eries Round type pressure gauge (with color zone) R L 9 29 8 6 9 3 2 odular.r.l. nits eries Improved visibility for lubricant drip with graduation for lubricant control raduation Improved

More information

Kompressoren. Oil Water Separators OWS

Kompressoren. Oil Water Separators OWS Kompressoren Oil Water Separators OWS Removal Of Contaminants in Compressed Air Condensate. Atmospheric air contains large amounts of water vapour and dust particles. These contaminants are mixed with

More information

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products. Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils

More information

SEPAR FILTER SEPAR 2000 SEPAR 2000

SEPAR FILTER SEPAR 2000 SEPAR 2000 2000 The 2000 is a water separator and fuel filter for light diesel fuel. An entirely new multistage centrifugal system ensures a 100% solution to the problem of water and particulate in fuel. 2000 offers:

More information

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright

More information

BOWIE PUMPS OPERATION - MAINTENANCE

BOWIE PUMPS OPERATION - MAINTENANCE BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped

More information

Atlas Copco Quality Air Solutions. Compressed Air Filters

Atlas Copco Quality Air Solutions. Compressed Air Filters Atlas Copco Quality Air Solutions Compressed Air Filters Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air for superior operational

More information

Backflush filter R8-30W

Backflush filter R8-30W Backflush filter R8-30W With internal pressure segment cleaning, rated pressure to 40 bar (580 psi) Connection sizes: DN 200 to DN 500, welded design 1. Features Powerful, fully automatic filtration _

More information

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves

CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves I-4057-H 2-08 CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves WATERBORNE COMPATIBLE CleanAir for a Quality Finish Selecting the right equipment

More information

Many Products...One Source

Many Products...One Source PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

Compressed Air Filters

Compressed Air Filters Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override Double 3/2 N.C. solenoid valve with manual override General The high pressure/high flow capacity solenoid valve, as not available on the market, was especially engineered by BIFFI in the early '70s for

More information

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS The key difference between a small vertical or bench-top sterilizer and industrial sterilizer is performance. Small saturated-steam sterilizers with vertical or horizontal chambers were devised many years

More information

Pressure calibration equipment

Pressure calibration equipment Pressure calibration equipment Pressure calibration evolution 1925 Westertoren in Amsterdam 30 meter mercury column (±40 bar) 1950 comparison test pump 21 st century Stiko gas driven differential deadweight

More information

T U R B I N E G A S M E T E R

T U R B I N E G A S M E T E R TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss

More information

PRESSURE REDUCING VALVES

PRESSURE REDUCING VALVES 0E0-GB PRESSURE REDUCING VAVES MAIN FEATURES The pressure reducing valve is able, by varying its pressure drops, to hold the downstream pressure of the fluid at a constant level against changes in the

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

DESIGN STANDARDS SECTION 23 60 00

DESIGN STANDARDS SECTION 23 60 00 PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.

More information

Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)

Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8

More information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact

More information

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems 185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Thermostatic Valve Replacement Cartridge and Rebuild Kit

Thermostatic Valve Replacement Cartridge and Rebuild Kit Thermostatic Valve Replacement Cartridge and Rebuild Kit Installation Instructions Rebuild kit for Ondine Thermostatic Mixing Valves including Models 25071 (1/2-inch) and 25072 (3/4-inch). Also fits models

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there

More information

Fixtures - Parts - Accessories to shampoo bowls

Fixtures - Parts - Accessories to shampoo bowls Page 1??? - For what brand of bowl do you need parts??? Find out by looking on the bottom of the bowl, between the front and strainer, where molded in the bottom is the brand and model number. For example,

More information

Hydraulic multidisc Brake H420

Hydraulic multidisc Brake H420 S320gb - rev 02/09 S E R V I C E Hydraulic multidisc Brake H420 A N U A L WARNER ELECTRIC EUROPE Rue Champfleur, B.P. 20095, F- 49182 St Barthélemy d Anjou Cedex Tél. +33 (0)2 41 21 24 24, Fax + 33 (0)2

More information

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9) Form TI420-KIT A Watts Industries Co. TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9) DESCRIPTION Thank you for purchasing a Powers kit. The Powers kit you

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

American- Darling 5¼" B-84-B-5.

American- Darling 5¼ B-84-B-5. -5 Sealed Lubrication Chamber Seals operating threads from water and debris which greatly reduces routine maintenance. Top Travel Stop Nut Helps prevent stem buckling and damage to bronze components which

More information

Screw Compressors 11-22kW

Screw Compressors 11-22kW INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

Wet alarm valves. Wet alarm valves. FM trim

Wet alarm valves. Wet alarm valves. FM trim Description Usually, a wet alarm valve station comprise: - a Rolland wet alarm valve linked to the water motor gong. - a set of valves and by pass used to test the system. - a drain valve. - a test valve

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,70 29.70

Diameter 3 4 6 8 Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,70 29.70 Description Usually, a wet alarm valve station comprise: a Rolland wet alarm valve linked to the water motor gong. a set of valves and by pass used to test the system. a drain valve. a test valve gauges

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

RC 195 Multiple Input Receiver-Controller

RC 195 Multiple Input Receiver-Controller Document No. 129-230 RC 195 Multiple Input Receiver-Controller Product Description The RC 195 Multiple Input Receiver-Controller is a pneumatic instrument that can be used as a one input (DA or RA), two

More information

Axial Piston Variable Motor A6VM

Axial Piston Variable Motor A6VM Electric Drives and Controls Hydraulics Linear otion and ssembly Technologies Pneumatics Service xial Piston Variable otor 6V RE 91 604/05.06 1/76 Replaces: 06.03 Technical data sheet Series 6 Sizes Nominal

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

FUEL & FUEL SYSTEM PROPERTIES OF FUEL

FUEL & FUEL SYSTEM PROPERTIES OF FUEL FUEL & FUEL SYSTEM PROPERTIES OF FUEL Fuel is a substance consumed by the engine to produce energy. The common fuels for internal combustion engines are: 1. Petrol 2. Power kerosene 3. High speed diesel

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow

More information

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant

More information

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For: 3M Water Filtration Products Installation and Instruction Manual For: CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings Installer: Please leave this manual with owner/operator. Owner/Operator:

More information

Ultra-Filter. Compressed Air Filter. DF Series

Ultra-Filter. Compressed Air Filter. DF Series Ultra-Filter DF Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Donaldson has built a comprehensive engineering, manufacturing,

More information

ETC -SV. Class 0 oil-free compressed air through catalysis

ETC -SV. Class 0 oil-free compressed air through catalysis Innovation QUALITy Reliability Worldwide ETC -SV Class 0 oil-free compressed air through catalysis The way to oil-free compressed air The ETC operating principle Through the process of catalytic oxidation,

More information

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing Technical data sheet R5.. Characterized control valves, 3-way, with external thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating

More information

B150 Series Commercial Brewer. Direct Plumb Kit

B150 Series Commercial Brewer. Direct Plumb Kit B150 Series Commercial Brewer Welcome Keurig Authorized Dealer! Direct Plumb Kit This manual provides: Installation of the Direct Plumb Kit (DPK) that allows you to connect your customer s B150 brewer

More information

AMX300 DirectConnect Mixing Valve Kits

AMX300 DirectConnect Mixing Valve Kits AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates

More information

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters

More information

1301 Series High-Pressure Regulators

1301 Series High-Pressure Regulators 1301 Series High-Pressure Regulators Bulletin 71.1:1301 December 2013 P10 Figure 1. Type 1301F Regulator Features Durable Stainless Steel Diaphragm For high-outlet pressure applications. Spare Valve Disk

More information

Type overview. Technical data

Type overview. Technical data Technical data sheet R3..xx-S.. Characterised control valve, 3-way, Internal thread For closed cold and warm water systems For modulating water-side control of air handling units and heating systems ir

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information