Accumulators, Accessories and Spares
|
|
|
- Melinda Hunter
- 9 years ago
- Views:
Transcription
1 Accumulators, Accessories and Spares HY /UK - Effective June 1st, 2013
2 Index Table of Contents Table of Contents 2 Introduction 3 How to Size? 4 General Information Accumulators 5-8 Bladder Accumulators Low Pressure EBV Series: How to order a Low Pressure Accumulator 9 EBV Series 0,5 to 5 Litres, 50 and EBV Series 10 to 200 Litres, ELG and OLG Series 20 and Bladder Accumulators High Pressure EHV Series: General Information Bladder Accumulator 16 EHV Series: How to order a Bladder Accumulator 17 EHV Series Litres, EHV Series 0,2-10 Litres, EHV Series Litres, EHV Series 1-54 Litres, EHVF Series Litres, 330, Flanged Fluid Port EHVF Series Litres, 350, Flanged Fluid Port EHV-DA Series Litres, 330, High Flow EHV-DA Series Litres, 350, High Flow Diaphragm Accumulators General Information Diapghragm Accumulator 34 ELM Series: How to order a Diaphragm Accumulator 35 ELM Series to 1.4 Litres ELM Series 1.4 to 3.5 Litres ELM Series to 1.4 Litres ELM Series 1.4 to 3.5 Litres Regulations & Protections Regulation Table EBV and EHV Internal & External Protection 46 Bladder Mixes 47 Accessories Clamps Support Brackets & Mounting Frames Charging Sets Safety Blocks Parker Hannifin
3 Introduction Introduction Solutions developed by Parker Olaer are used in a large number of industrial sectors: aeronautics, chemistry, defence, mining, railway construction, Formula 1, machine tools, agriculture, oil and gas, metallurgy, renewable energies, etc. This variety of applications requires extensive knowledge of the products and their major components, particularly the bladder. In order to reinforce its position, Parker Olaer is the co-owner of its main bladder supplier. For either a standard application or designing solutions for a specific requirement, Parker Olaer engineers have the experience in elastomers and knowledge of the latest technological Parker ACDE Colombes (Paris, France) The historical cradle of Olaer Industries, which is now Parker ACDE Paris Manufacture: Bladder Accumulators Diaphragm Accumulators Piston Accumulators up to 320 Low Pressure Bladder Accumulators up to 575 litres Piston Accumulators for wind and mobile applications Attenuators Special Accumulators for aerospace and racing Accessories Accumulator Systems Paris, France Piston accumulators for wind and some mobile CE approval (Europe), SELO approval (China) others under development. Diameters 80, 100 & 140 mm and pressures 320. Parker ACDE Hellaby (Bramley, UK) Historically a part of Cylinder Division, then the Global Accumulator Division. Manufacture: Piston accumulators up to Ø 360 mm / 350 Crimped piston technology Bladder accumulators Diaphragm accumulators Safety blocks Accessories Parker Hellaby, UK (Parker GAD) Focus on piston accumulators industry & mobile CE Approval others under development. Diameters 360 mm and pressures 350. Crimped piston accumulators 275 < 20 Litres developments in metal and composite shells. This allows Parker Olaer to propose reduced weight accumulators and other design innovations. We provide cost effective solutions based upon our customer s needs. Parker Olaer utilizes comprehensive tools and resources including an applications database, CAD/CAM, finite element analysis, reliability studies and simulation software which enable us to optimize design and performance. Parker ACDE Sandycroft (Chester, UK) 250 year history as a company. Focus on: Oil & Gas markets globally + UK market with their own gas valves and fluid ports. Manufacture: Bladder Accumulators - forged, welded and machined Piston Accumulators in various materials and pressures Pulsation Dampers Pressure Compensators Safety Blocks Carbon Steel and Stainless Steel Various other accessories & Accumulator Systems Large variety of approvals Parker ACDE Sandycroft, UK Focus on Oil & Gas + specials. Special materials, diameters > mm for any pressures Any diameter at pressures > 400. Pressure up to 3000 available. Special pressure vessel approvals available. Parker ACDE Leini (Turin, Italy) 47 year history Manufacture: Welded Bladder Accumulators low pressure up to 35 CS/SS Welded Bladder Accumulators high pressure (up to 200 ) CS/SS Piston Accumulators CS and SS, up to 350 / up to 540 mm bore Pulsation Dampers Piston / Bladder accumulator systems. Gas bottle systems Large variety of approvals (PED & ASME most requested) Parker ACDE Leinì Focus on Oil & Gas, Industrial, Special welded pressure vessels/tanks on customer needs Racks. 3 Parker Hannifin
4 How to size How to size? Parker Olaer has developed very sophisticated simulation software to optimize accumulator sizing recommendations. The behaviour of accumulators used in applications such as pulsation dampening, surge alleviation, thermal expansion and energy storage can be simulated. Our software can be downloaded from our website You may also contact your local Parker Olaer office for sizing assistance. The graph is useful to estimate the size of an accumulator used to store or deliver a specific volume of liquid within a given pressure range. These curves are the graphic representation of an adiabatic * cycle (fast cycling rate - N = 1.4 perfect gas assumption) or isothermal * cycle for an accumulator working at 20 C with a Pre-charge P0 = 0,9 P1. They do not take into consideration the real gas compression correction factor, the real adiabatic coefficient and the polytropic rate of the application. Depending on the application data, the influence of these factors may be significant, and require that some calculations adjustments be made. The Parker Olaer simulation software takes all these factors into account. Sizing of an accumulator to be installed in the following example conditions: P2 : Maximum available pressure : 210 Bar P1 : Minimum working pressure : 100 Bar P0 : Nitrogen Pre-charge : 90 Bar V : Volume to be stored : 14L Condition : Isothermal (No temperature variation) A/Compression ration = P2/P1 = 210/100 = 2,1 B/From the value 2,1 on the axis, draw a vertical line that intersects the isothermal reference curve in A. C/From the value 14 on the V axis, draw a vertical line. The intersection point of this line with the horizontal line meeting A indicates a required accumulator size of 32 L. Calculation of the volume drawn off from an accumulator. Accumulator size = 12 L P2 = 185 Bar; P1 = 100 Bar; P0 = 90 Bar; Adiabatic condition = P2/P1 = 185/100 = 1,85 V : 3,5 litres Accumulator size in litre *Reminder Isothermal: The transformation is said to be isothermal when the compression or expansion of the gas occurs at a rate slow enough to allow a good thermal exchange, allowing the gas to remain at constant temperature. AL C Adiabatic: The transformation is said to be adiabatic when the cycle is quick and does not allow a temperature exchange with the ambient media. Basic sizing chart for accumulator used in energy storage. stored volume 4 Parker Hannifin
5 General Information Accumulators General Information Accumulators Olaer, pioneer of high pressure equipment, was founded in 1938 by Jean Mercier. Using his experience, passion for research and extensive knowledge of hydraulics in the demanding field of aeronautics, Mr. Mercier engineered the first gas loaded bladder accumulator. This has lead to Olaer becoming the indisputable international leader in this field. We provide cost effective solutions based upon our customer s needs. Parker Olaer utilizes comprehensive tools and resources including an applications database, CAD/CAM, finite element analysis, reliability studies and simulation software which enable us to optimize design and performance. This variety of applications requires extensive knowledge of the products and their major components, particularly the bladder. In order to reinforce its position, Olaer is the co-owner of its main bladder supplier. For either a standard application or designing solutions for a specific requirement, Parker Olaer engineers have the experience in elastomers and knowledge of the latest technological developments in metal and composite shells. This allows Parker Olaer to propose reduced weight accumulators and other design innovations. Operation The Olaer gas loaded accumulator is an essential component for the optimum operation of a hydraulic circuit. In hydraulic circuits, the accumulator enables: An energy reserve which is instantaneously available to the system Compensation of pressure fluctuations and spikes. Pump pulsation dampening Advantages/Your benefits The gas loaded bladder accumulators provide major advantages in terms of the energy output of the device and maintenance of the installation: Reduction in working costs - Reduces installed electrical power - Significant energy saving Increase lifetime of equipment - Reduces pulsations - Protects against pressure peaks Reduction in maintenance cost - Reduces wear of hydraulic components - Requires minimum maintenance of the installation 5 Parker Hannifin
6 General Information Accumulators Operating principle Operation of the Olaer gas loaded bladder accumulator is based on the considerable difference in compressibility between a gas and a liquid, enabling a large quantity of energy to be stored in an extremely compact form. This enables a liquid under pressure to be accumulated, stored and recovered at any time. Its special design allows the bladder (the strategic component) to compress the gas and usually form into three lobes in order for the accumulator to store, then to deliver the fluid under pressure, as required. P 0 V 0 A P 1 V 1 B P 2 V 2 C V V0 = Capacity in nitrogen of the accumulator V1 = Gas volume at the minimum hydraulic pressure V2 = Gas volume at the maximum hydraulic pressure V = Returned and/or stored volume of working fluid between P1 and P2 P0 = Initial preload of the accumulator P1 = Gas pressure at the minimum hydraulic pressure P2 = Gas pressure at the maximum hydraulic pressure A - Bladder in the Pre-charge position, B - Position at the minimum which means that the accumulator only operating pressure. There must be a contains nitrogen. The anti-extrusion certain amount of fluid between the system closes the hydraulic orifice bladder and the hydraulic orifice, such P0 < P1 < P2 which prevents the destruction of the bladder. In low pressure accumulators the bladder rests against the grid. Maximum pressure differential (P2/P0): 4:1 that the anti-extrusion system does not close the hydraulic orifice. C - Position at the maximum operating pressure. The volume difference between the minimum and maximum positions of the operating pressures represents the working fluid quantity. Technical Characteristics The accumulator comprises of a pressure vessel including valve stem device, a rubber bladder and an anti-extrusion system. Shell material options include alloyed steel, stainless steel, aluminium, titanium and composites. Various bladder materials available which are compatible with a range of fluids and temperatures. Different anti-extrusion systems can be used for specific applications (fluidport assembly for high pressure, grid for low pressure, or button). As the market leader in bladder type accumulators, Parker Olaer has participated in the development of the EN 14359:2006 standard, which specifies the material, design, manufacturing, fatigue tests, safety devices and documentation (including the instruction manual), for pressure accumulators and gas bottles for hydraulic applications. Taking into account the different needs of various applications, Parker Olaer proposes different protections external and/or internal: Bare metal, nickel plating, epoxy paint, PTFE, Rilsan and phenolic coating. This extensive range enables us to offer accumulators operating from 50 to +150 C with pressures of up to 1500 Bar and capacities of up to 575 litres. 6 Parker Hannifin
7 General Information Accumulators Different elastomer options Parker Olaer can offer many different elastomer options depending on the application where the product is used. Two of the most important parameters for deciding the rubber compound to be used is: 1. The minimum and maximum operating temperature of the system. 2. The fluid type in the system. The most common bladder for hydraulic systems with mineral oil is Nitrile (also called NBR or Buna). A host of other rubbers such as Butyl, Hydrin, Viton or EPDM and more are available. Please contact your local Parker Olaer office for your specific application. Also, be sure to note that even if you change the bladder to one with particularly high or low temperature characteristics, the pressure vessel temperature range (TS) does not change. Check that the operating temperature range of the new chosen bladder is included in the temperature range of the pressure vessel. Regulations and Approvals Parker Olaer designs and manufactures gas loaded accumulators for use in all countries, as well as other industry specific approvals including oil & gas, naval and nuclear. The main regulations in force are PED for European market, ASME for US market and SELO for Chinese market. As a service, Parker Olaer can recommend the appropriate regulations applicable if customers know the country where the accumulator will be installed. When operating in dangerous and explosive environments, Parker Olaer has designed an ATEX Group II cat. 2 and 3 range of accumulators. Some of these regulations call for the use of safety devices to protect the accumulator against over pressure. Solutions may include hydraulic safety blocks, relief valves or gas side safety devices such as burst discs and fuse plugs. Parker Olaer has designed and proposed a complete range of safety devices suitable for the applicable regulations. To meet the needs of our customers, Parker Olaer can supply accumulators with multiple approvals. With regard to environmental concerns Parker Olaer s product range complies with REACH regulations. 7 Parker Hannifin
8 General Information Accumulators Top Repairable accumulators This accumulator type can be serviced from both the fluid side or the gas side. The design utilizes many standard accumulator parts, but is unique in that it does not have to be removed from the system in order to change the bladder. This can in many applications be a great advantage. The gas end adaptor mechanically locks to prevent disassembly under pressure. High flow bladder accumulators Parker Olaer has several versions of bladder accumulators for high flow applications, depending on how high the flow requirements will be. The first step up from our standard is a high flow version with a 2 fluid port, where the internal geometrics of the port body and poppet valve are specifically designed for that purpose. The next step is a 2 ½ fluid port which will provide even higher flows. For ultimate demands a 4 fluid port can also be provided. Please note that the last two solutions require shells with larger openings, and are not always available in all shell sizes. Parker Olaer can tailor make the different parts to suit your technical needs. Transfer rier This range is a special adaptation of the bladder accumulator, with a pipe connected to the gas side of the accumulator. The most common application is to use the transfer accumulator in energy storage applications. The accumulator is connected to an additional volume of nitrogen, for example a gas cylinder. This increases the total volume of the system. Such systems are often mounted together in a battery or rack type installation. A Transfer Barrier Accumulator can also be used to separate two liquids or a gas and liquid. It is usually a question of separating two liquids, one of which is aggressive or contaminated. To limit the number of parts in contact with the aggressive liquid, it is common practice to put the aggressive fluid inside the bladder and therefore connect on what is normally the gas side. Dependant upon the accumulator volume, the displaced volume must not exceed 80% of the volume of the transfer accumulator. 8 Parker Hannifin
9 Low Pressure Bladder Accumulators EBV Series: How to order a low pressure accumulator Technical Characteristics The accumulator comprises a forged or welded steel shell, a rubber bladder and anti-extrusion system. Shell material options include alloyed steel, stainless steel, aluminium, titanium and composites. Various bladder materials available which are compatible with a range of fluids and temperatures. Anti-extrusion system; perforated bushing. Taking into account the different needs of various applications, Parker Olaer offers different protections external and/or internal: Bare metal, nickel plating, epoxy paint, PTFE, Rilsan and phenolic coating. This extensive range enables us to offer accumulators operating from 40 to +130 C with pressures of up to 80 Bar and capacities of up to 575 litres. Atex versions are also available for some accumulators in fluid groups 1 or 2 as per Article 9 section 2.1 and 2.2 of PED. As the market leader in bladder type accumulators, Parker Olaer has participated in the development of the EN 14359:2006 standard, which specifies the material, design, manufacturing, fatigue tests, safety devices and documentation (including the instruction manual), for pressure accumulators and gas bottles for hydraulic applications. + Part Number (11 characters) Nitrogen Gas Connection to Clamp for Support Mounting + Pre-charge be specified fixation Bracket Frame Example EBV / P0 = 5b PN 20 DN 200 D368 X 2 CE 300 EF1 Eye Fit Series EBV : Low pressure bladder accumulator ETBV : Transfer type EBV Volume in Litres Max. working Pressure (PS) in Regulation Code 00 : According to the PED, article 3.3 for the 0.5 L and 1 L volume 90 : According to the PED for all other volumes Others: consult the table pages 44 & 45 Part Number: 6 characters Construction: 1 character 0 : All ranges except transfer 3 : Transfer range 5 : Transfer stainless steel range Shell Construction: 2 characters 11 : In carbon steel 19 : Stainless steel, usable for ATEX Others: consult the table page 46 Bladder Mix: 2 characters 20 : Accumulators > 100L NBR NITRILE STANDARD 25 : Standard construction NBR NITRILE STANDARD Other mixes: Consult the table page 47 Nitrogen gas pressure without specification : Accumulators will be delivered with a storage pressure (between 2 and 5 ) with specification : in at 20 C limited to 20 at maximum working temperature Connection to be specified Clamp Specify model X quantity Support Bracket Specify model Mounting Frame Specify model Lifting Eye Proposal for easy handling 9 Parker Hannifin
10 Low Pressure Bladder Accumulators EBV Series 50 & 80 BAR, Volume 0.5 to 5 Litres EBV /00* Precharge EBV 1-80/00* Adaptor Flange Clamps Support Bracket Threaded G 1 cyl G 1 cyl - - 1½ ANSI 150 lbs 1½ ANSI 300 lbs Standard version (Carbon Steel shell/nbr mix) for mineral oils temperature from - 15 up to 100 C According to PED 97/23/EC, Fluid Group 2 s, Accessories Dimensions (quantity) E95 (1) E114 (1) - CE 89 Complete Repair Kit KIT EBV / KIT EBV 1-80/ EBV / G 1 cyl ½ ANSI 150 lbs ½ ANSI 300 lbs E114 (2) CE KIT EBV / EBV 5-80/ G 1 cyl ½ ANSI 150 lbs ½ ANSI 300 lbs E114 (2) CE KIT EBV 5-80/ * according to the PED, article 3.3 Accumulators are delivered with the nitrogen pre-charge 3. The charging pressure for low pressure accumulators must never exceed 20 at the maximum operating temperature. 10 Parker Hannifin
11 Low Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Max Weight kg O-ring ø int x ø tore A max height B C Dimensions in mm ød max ød øh G connection EBV /00* x G2 cyl. EBV 1-80/00* x G2 cyl. EBV / x G2 cyl. EBV 5-80/ x G2 cyl. G O Ring Fittings & Flanges page 9 Above dimensions are in mm and are subject to manufacturing tolerances. 11 Parker Hannifin
12 Low Pressure Bladder Accumulator EBV Series 40 BAR, Volume 10 to 200 Litres Standard Version (Carbon Steel shell/nbr mix) for mineral oils temperature from - 15 up to 100 C According to PED 97/23/EC, Fluid Group 2 s, Accessories Dimensions EBV 10-40/90 Precharge 1-20 Adaptor Flange Clamps Threaded G 2 cyl 4 ANSI 150 lbs 4 ANSI 300 lbs (quantity) D215 (2) Support Bracket CE 159A Lifting Eye Complete Repair Kit KIT EBV 10-40/ EBV 20-40/ G 2 cyl ANSI 150 lbs ANSI 300 lbs D215 (2) CE 159A KIT EBV 20-40/ EBV 32-40/ G 2 cyl ANSI 150 lbs ANSI 300 lbs D215 (2) CE 159A KIT EBV 32-40/ EBV 50-40/ G 2 cyl ANSI 150 lbs ANSI 300 lbs D215 (2) CE 159A KIT EBV 50-40/ EBV / EBV / ANSI 150 lbs ANSI 150 lbs ANSI 300 lbs ANSI 300 lbs D368 (2) D368 (2) CE CE KIT EBV / KIT EBV / Accumulators are delivered with the nitrogen pre-charge 3. The charging pressure for low pressure accumulators must never exceed 20 at the maximum operating temperature. 12 Parker Hannifin
13 Low Pressure Bladder Accumulator Effective Gas vol. Litres Max. Working pressure (PS) Max Weight kg O-ring ø int x ø tore A max height B C Dimensions in mm ød max ød G connection øh EBV 10-40/ x G3½ cyl. 120 EBV 20-40/ x G3½ cyl. 120 EBV 32-40/ x G3½ cyl. 120 EBV 50-40/ x G3½ cyl. 120 EBV / x M205x3 224 EBV / x M205x3 224 G O Ring Fittings & Flanges page 9 Above dimensions are in mm and are subject to manufacturing tolerances. 13 Parker Hannifin
14 Low Pressure Bladder Accumulators ELG and OLG Series, 20 & 50 BAR Standard Version (steel shell or stainless steel/ NBR mix) for mineral oils temperature from - 15 up to 100 C According to PED 97/23/EC, EN Fluid Group 2 s, Accessories Dimensions OLG /00 (1) Pre-charge OLG 1-20/00 (2) ELG 4-20/90 3/4 (3) ELG 4-20/90 2 (3) (1) according to the PED, article 3.3 stainless steel (2) according to the PED, article 3.3 (3) according to the PED stainless steel Clamps (quantity) - E106 (1) E155 (1) E155 (1) Parker Hannifin
15 Low Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Weight kg Gas Connection A max height B C Dimensions in mm ød max ø Spot facing x depth SW G connection OLG /00 (1) V x flats 36 A/F G ¾ cyl. OLG 1-20/00 (2) V flats 46 A/F G 1 cyl. ELG 4-20/90 3/4 (3) V x flats 82 A/F G ¾ cyl. ELG 4-20/90 2 (3) V x flats 82 A/F G 2 cyl. G G G Above dimensions are in mm and are subject to manufacturing tolerances. 15 Parker Hannifin
16 High Pressure Bladder Accumulators EHV Series: General Information Bladder Accumulators Operation of the OLAER gas loaded bladder accumulator is based on the considerable difference in compressibility between a gas and a liquid, enabling a large quantity of energy to be stored in an extremely compact form. This enables a liquid under pressure to be accumulated, stored and recovered at any time. Its special design allows the bladder (the strategic component) to compress the gas and usually form into three lobes in order for the accumulator to store, then to deliver the fluid under pressure, as required. The OLAER gas loaded accumulator is an essential component for the optimum operation of a hydraulic circuit. In hydraulic circuits, the accumulator enables: An energy reserve which is instantaneously available to the system Compensation of pressure fluctuations and spikes. Pump pulsation dampening The accumulator comprises of a pressure vessel, a rubber bladder and an anti-extrusion system. Shell material options include alloyed steel, stainless steel, aluminium, titanium and composites. Various bladder materials available which are compatible with a range of fluids and temperatures. Different anti-extrusion systems can be used for specific applications (fluidport assembly for high pressure, grid for low pressure, or button). Taking into account the different needs of various applications, Olaer proposes different protections external and/or internal: Bare metal, nickel plating, epoxy paint, PTFE, Rilsan and phenolic coating. This extensive range enables us to offer accumulators operating from 50 to +150 C with pressures of up to 1500 Bar and capacities of up to 575 litres. As the market leader in bladder type accumulators, Olaer has participated in the development of the EN 14359:2006 standard, which specifies the material, design, manufacturing, tests, safety devices and documentation (including the instruction manual), for pressure accumulators and gas bottles for hydraulic applications. P 0 V 0 A P 1 V 1 B P0 < P1 < P2 P 2 V 2 C V V0 = Capacity in nitrogen of the accumulator V1 = Gas volume at the minimum hydraulic pressure V2 = Gas volume at the maximum hydraulic pressure V = Returned and/or stored volume of working fluid between P1 and P2 P0 = Initial preload of the accumulator P1 = Gas pressure at the minimum hydraulic pressure P2 = Gas pressure at the maximum hydraulic pressure A - Bladder in the Pre-charge position, which means that the accumulator only contains nitrogen. The anti-extrusion system closes the hydraulic orifice which prevents the destruction of the bladder. In low pressure accumulators the bladder rests against the grid. B - Position at the minimum operating pressure. There must be a certain amount of fluid between the bladder and the hydraulic orifice, such that the anti-extrusion system does not close the hydraulic orifice. C - Position at the maximum operating pressure. The volume difference between the minimum and maximum positions of the operating pressures represents the working fluid quantity. 16 Parker Hannifin
17 High Pressure Bladder Accumulators EHV Series: How to order a high pressure accumulator Technical Characteristics The accumulator comprises a forged steel shell, a rubber bladder and a fluid port assembly. Shell material options include alloyed steel, stainless steel, aluminium, titanium and composites. Various bladder materials available which are compatible with a range of fluids and temperatures. Anti-extrusion system; fluidport assembly for high pressure. Taking into account the different needs of various applications, Parker Olaer offers different protections external and/or internal: Bare metal, nickel plating, epoxy paint, PTFE, Rilsan and phenolic coating. This extensive range enables us to offer accumulators operating from 50 to +150 C with pressures of up to 690 Bar and capacities of up to 57 litres. As the market leader in bladder type accumulators, Parker Olaer has participated in the development of the EN 14359:2006 standard, which specifies the material, design, manufacturing, fatigue tests, safety devices and documentation (including the instruction manual), for pressure accumulators and gas bottles for hydraulic applications. + Part Number (11 characters) Nitrogen Gas Pre-charge Connection to be specified Clamp for fixation Support Bracket Mounting Frame Example EHV / P0 = 200b G 1 D226 X 2 CE 300 EF1 Eye Fit Series EHV: High pressure bladder accumulator EHVF: EHV with Flange EHVDA: High Flow EHV ETHV: Transfer type EHV Volume in Litres Max. working Pressure (PS) in Regulation Code 00 : According to the PED article 3.3 for the volumes from 0.2 to 1L, Fluid Group 2 90 : According to the PED Others: consult the table pages 44 & 45 Part Number: 6 characters Construction: 1 character 0 : All ranges except transfer 3 : Transfer range 5 : Transfer stainless steel range Shell Construction: 2 characters 11 : In carbon steel 19 : Stainless steel, usable for ATEX Others: consult the table page 46 Bladder Mix: 2 characters 20 : Accumulators > 100L NBR NITRILE STANDARD 25 : Standard construction NBR NITRILE STANDARD Other mixes: Consult the table page 47 Nitrogen gas Pressure Without specification: Accumulators will be delivered with a storage pressure between 2 and 5. With specification: in specified at 20 C Connection to be specified Clamp Specify model X quantity Support Bracket Specify model Mounting Frame Specify model Lifting Eye Proposal for easy handling 17 Parker Hannifin
18 High Pressure Bladder Accumulators EHV Series 330 BAR, 10 to 57 Litres Standard version (Carbon Steel shell/nbr mix) for mineral oils temperature from - 20 up to 80 C According to PED 97/23/EC, EN Fluid Group 2 s, Accessories Dimensions EHV /90 Valve model see drawing Pre-charge Adaptor Clamps Threaded G 1 cyl (quantity) D226 (2) Support Bracket CE159A Mounting Frame EF2 Lifting Eye Complete Repair Kit KIT EHV / A B EHV /90 G 1 cyl D226 (2) CE159A EF2 KIT EHV / A B EHV /90 G 1 cyl D226 (2) CE159A EF2 KIT EHV / A B EHV /90 G 1 cyl D226 (2) CE159A EF2 KIT EHV / A B EHV /90 G 1 cyl D226 (2) CE159A EF3 KIT EHV / A B EHV /90 G 1 cyl D226 (2) CE159A EF3 KIT EHV / A B EHV /90 G 1 cyl D226 (2) CE159A EF3 KIT EHV / A B EHV /90 G 1 cyl D226 (2) CE159A EF3 KIT EHV / A B of valve stem 5/8 18 UNF (A) of valve stem 7/8 14 UNF (B) 18 Parker Hannifin
19 High Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Max Flow Rate l/min Weight kg Gas connection A max height B C Dimensions in mm ød max ød øe F on flats G connection EHV / /8 18 UNF G 2 7/8 14 UNF EHV / /8 18 UNF G 2 7/8 14 UNF EHV / /8 18 UNF G 2 7/8 14 UNF EHV / /8 18 UNF G 2 7/8 14 UNF EHV / /8 18 UNF G 2 7/8 14 UNF EHV / /8 18 UNF G 2 7/8 14 UNF EHV / /8 18 UNF G 2 7/8 14 UNF EHV / /8 18 UNF G 2 7/8 14 UNF Ø d Ø D Ø G Ø E F O'Ring B A C Above dimensions are in mm and are subject to manufacturing tolerances. 19 Parker Hannifin
20 High Pressure Bladder Accumulators EHV Series 350, 0.2 to 10 Litres Standard Version (Carbon Steel shell/nbr mix) for mineral oils temperature from - 20 up to 80 C According to PED 97/23/EC, EN Fluid Group 2 s, Accessories Dimensions Support Bracket Mounting Frame Complete Repair Kit Valve Pre-charge Adaptor Clamps Lifting Eye model see Threaded (quantity) drawing EHV /00* G 1/4 cyl A56 (1) KIT EHV / A EHV /00* G 3/8 cyl E95 (1) KIT EHV / A EHV 1-350/00* G 3/8 cyl E114 (1) CE 89 KIT EHV 1-350/ C B EHV /90 G 3/8 cyl E114 (1) CE 89 KIT EHV / C B EHV /90 G 3/4 cyl E114 (2) CE 89 KIT EHV / C B EHV 4-350/90 G 3/4 cyl E168 (1) CE108 EF1 KIT EHV 4-350/ C B EHV 5-350/90 G 3/4 cyl E114 (2) CE 89 KIT EHV 5-350/ C B EHV 6-350/90 G 3/4 cyl E168 (2) CE108 EF1 KIT EHV 6-350/ C B EHV /90 G 3/4 cyl E168 (2) CE108 EF1 KIT EHV / C B * according to the PED, article 3.3 of valve stem 5/8 18 UNF 1A (A) of valve stem 7/8 14 UNF (B) of valve stem 7/8 14 UNF (C) 20 Parker Hannifin
21 High Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Max Flow Rate l/min Weight kg Gas connection A max height B Dimensions in mm C ød max ød øe F on flats G connection EHV /00* /8 18 UNF G ½ EHV /00* /8 18 UNF G ¾ EHV 1-350/00* /8 14 UNF G ¾ 7/8 14 UNF EHV / /8 14 UNF G ¾ 7/8 14 UNF EHV / /8 14 UNF G 1 ¼ 7/8 14 UNF EHV 4-350/ /8 14 UNF G 1 ¼ 7/8 14 UNF EHV 5-350/ /8 14 UNF G 1 ¼ 7/8 14 UNF EHV 6-350/ /8 14 UNF G 1 ¼ 7/8 14 UNF EHV / /8 14 UNF G 1 ¼ 7/8 14 UNF Ø d Ø D Ø G Ø E F O'Ring B C A Above dimensions are in mm and are subject to manufacturing tolerances. 21 Parker Hannifin
22 High Pressure Bladder Accumulators EHV Series 480 BAR, 10 to 50 Litres Standard Version (Steel shell/nbr mix) for mineral oils temperature from - 20 up to 80 C According to PED 97/23/EC, EN Fluid Group 2 s, Accessories Dimensions EHV / Pre-charge Adaptor Clamps Threaded G 1 cyl (quantity) D226 (2) Support Bracket CE159A Mounting Frame EF2 Lifting Eye Complete Repair Kit KIT EHV / EHV / G 1 cyl D226 (2) CE159A EF KIT EHV / EHV / G 1 cyl D226 (2) CE159A EF KIT EHV / EHV / G 1 cyl D226 (2) CE159A EF KIT EHV / EHV / G 1 cyl D226 (2) CE159A EF KIT EHV / of valve stem 7/8 14 UNF 22 Parker Hannifin
23 High Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Max Flow Rate l/min Weight kg Gas connection A max height B C Dimensions in mm ød max ød øe F on flats G connection EHV / /8 14 UNF G 2 EHV / /8 14 UNF G 2 EHV / /8 14 UNF G 2 EHV / /8 14 UNF G 2 EHV / /8 14 UNF G 2 Ø d Ø D Ø G Ø E F O'Ring B A C Above dimensions are in mm and are subject to manufacturing tolerances. 23 Parker Hannifin
24 High Pressure Bladder Accumulators EHV Series 690 BAR, 1 to 54 Litres Standard Version (Carbon Steel shell/nbr mix) for mineral oils temperature from - 20 up to 80 C According to PED 97/23, EN Fluid Group 2 s, Accessories Dimensions EHV 1-690/00* Pre-charge Adaptor Clamps Threaded G 1/2 cyl (quantity) E114 (1) Support Bracket CE89 Lifting Eye Complete Repair Kit KIT EHV 1-690/ EHV / G 1/2 cyl E114 (2) CE KIT EHV / EHV 5-690/ G 1/2 cyl E114 (2) CE KIT EHV 5-690/ * according to the PED, article 3.3 EHV 690 EHV / V-DC-691 EHV / V-DC-691 EHV / V-DC-691 EHV / V-DC-691 Pre-charge Adaptor Clamps Support Bracket Complete Repair Kit Threaded (quantity) KIT EHV / KIT EHV / KIT EHV / KIT EHV / of valve stem 7/8 14 UNF of valve stem 5/8 18 UNF Accumulators are delivered with the nitrogen Pre-charge Parker Hannifin
25 High Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Max Flow Rate l/min Weight kg A max height B C ød max Dimensions in mm ød øe F on flats G connection** EHV 1-690/00* G 1 EHV / G 1 EHV 5-690/ G 1 ** Requires a special adaptor Effective Gas vol. Litres Max. Working pressure (PS) Max Flow Rate l/min Weight kg A max height B C Dimensions in mm ød max ød øe F on flats G connection** EHV / EHV / EHV / EHV / ** Requires a special adaptor Ø d Ø D Ø G Ø E F O'Ring B A C Above dimensions are in mm and are subject to manufacturing tolerances. 25 Parker Hannifin
26 High Pressure Bladder Accumulators EHVF Series 330 BAR, 10 to 57 Litres Flanged Fluid Port Standard Version (Steel shell/nbr mix) for mineral oils temperature from - 20 up to 80 C According to PED 97/23/EC, EN Fluid Group 2 s, Accessories Dimensions Pre-charge Flange Clamps (quantity) Support Bracket Mounting Frame Lifting Eye Complete Repair Kit EHVF /90 BR D226 (2) CE 159A EF2 KIT EHVF / EHVF / BR D226 (2) CE 159A EF KIT EHVF / EHVF / BR D226 (2) CE 159A EF KIT EHVF / EHVF / BR D226 (2) CE 159A EF KIT EHVF / EHVF / BR D226 (2) CE 159A EF KIT EHVF / EHVF / BR D226 (2) CE 159A EF KIT EHVF / EHVF / BR D226 (2) CE 159A EF KIT EHVF / EHVF / BR D226 (2) CE 159A EF KIT EHVF / of valve stem 5/8 18 UNF Accumulators are delivered with the nitrogen Pre-charge Parker Hannifin
27 High Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Max Flow Rate l/min Weight kg Gas connection A max height B C ød max Dimensions in mm ød øe øg connection F on flats øl M EHVF / /8 18 UNF EHVF / /8 18 UNF EHVF / /8 18 UNF EHVF / /8 18 UNF EHVF / /8 18 UNF EHVF / /8 18 UNF EHVF / /8 18 UNF EHVF / /8 18 UNF Note: Connection (norme ISO 6162): 1 SAE 6000 PSI. M Ø d Ø D Ø G Ø L Ø E F O'Ring B C A Above dimensions are in mm and are subject to manufacturing tolerances. 27 Parker Hannifin
28 High Pressure Bladder Accumulators EHVF Series 350 BAR, 2.5 to 10 Litres Flanged Fluid Port Standard Version (Steel shell/nbr mix) for mineral oils temperature from - 20 up to 80 C According to PED 97/23/EC, EN Fluid Group 2 s, Accessories Dimensions Pre-charge Flange Clamps Support Bracket Mounting Frame Lifting Eye Complete Repair Kit (quantity) EHVF / BR E114 (2) CE KIT EHVF / EHVF 4-350/90 BR E168 (1) CE108 EF1 KIT EHVF 4-350/ EHVF 5-350/ BR E114 (2) CE KIT EHVF 5-350/ EHVF 6-350/90 BR E168 (1) CE108 EF1 KIT EHVF 6-350/ EHVF /90 BR E168 (2) CE108 EF1 KIT EHVF / of valve stem 7/8 14 UNF 28 Parker Hannifin
29 High Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Max Flow Rate l/min Weight kg Gas connection A max height B C ød max Dimensions in mm ød øe F on flats øg øl Max M EHVF / /8 14 UNF EHVF 4-350/ /8 14 UNF EHVF 5-350/ /8 14 UNF EHVF 6-350/ /8 14 UNF EHVF / /8 14 UNF Note: Connection (norme ISO 6162): 1 SAE 6000 PSI. M Ø d Ø D Ø G Ø L Ø E F O'Ring B C A Above dimensions are in mm and are subject to manufacturing tolerances. 29 Parker Hannifin
30 High Pressure Bladder Accumulators EHV-DA Series 330, 10 to 57 Litres High Flow fluid port, 1200 l/min Standard version (Steel shell/nbr mix) for mineral oils temperature from - 20 up to 80 C For high flow (up to 1200 Litres/min), According to PED 97/23/EC, EN Fluid Group 2 s, Accessories Dimensions Pre-charge Adaptor Clamps Threaded (quantity) Support Bracket Mounting Frame Lifting Eye Complete Repair Kit EHV /90/DA G 1 cyl D226 (2) CE 159A EF2 KIT EHV / EHV /90/DA G 1 cyl D226 (2) CE 159A EF KIT EHV / EHV /90/DA G 1 cyl D226 (2) CE 159A EF KIT EHV / EHV /90/DA G 1 cyl D226 (2) CE 159A EF KIT EHV / EHV /90/DA G 1 cyl D226 (2) CE 159A EF KIT EHV / EHV /90/DA G 1 cyl D226 (2) CE 159A EF KIT EHV / EHV /90/DA G 1 cyl D226 (2) CE 159A EF KIT EHV / EHV /90/DA G 1 cyl D226 (2) CE 159A EF KIT EHV / of valve stem 5/8 18 UNF 30 Parker Hannifin
31 High Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Max Flow Rate l/min Max Weight kg Gas Connection A max height B C ød max Dimensions in mm ød øe øg connection F on flats EHV /90/DA /8 18 UNF G 2 70 EHV /90/DA /8 18 UNF G 2 70 EHV /90/DA /8 18 UNF G 2 70 EHV /90/DA /8 18 UNF G 2 70 EHV /90/DA /8 18 UNF G 2 70 EHV /90/DA /8 18 UNF G 2 70 EHV /90/DA /8 18 UNF G 2 70 EHV /90/DA /8 18 UNF G 2 70 Ø d Ø D Ø G Ø E F O'Ring B C A Above dimensions are in mm and are subject to manufacturing tolerances. 31 Parker Hannifin
32 High Pressure Bladder Accumulators EHV-DA Series 350 BAR, 2.5 to 10 Litres High Flow fluid port, 570 l/min Standard Version (Steel shell/nbr mix) for mineral oils temperature from - 20 up to 80 C For high flow (up to 570 Litres/min), According to PED 97/23/CE, EN Fluid Group 2 s, Accessories Dimensions Pre-charge Adaptor Clamps Threaded (quantity) Support Bracket Mounting Frame Lifting Eye Complete Repair Kit EHV /90/DA EHV 4-350/90/DA EHV 5-350/90/DA EHV 6-350/90/DA EHV /90/DA G ¾ cyl G ¾ cyl G ¾ cyl G ¾ cyl G ¾ cyl E114 (2) E168 (2) E114 (2) E168 (2) E168 (2) CE CE CE CE CE EF EF EF1 KIT EHV / KIT EHV 4-350/ KIT EHV 5-350/ KIT EHV 6-350/ KIT EHV / of valve stem 7/8 14 UNF 32 Parker Hannifin
33 High Pressure Bladder Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Max Flow Rate lt/min Max Weight kg Gas connection A max height B C Dimensions in mm ød max ød øe øg connection F on flats EHV /90/DA /8 14 UNF G 1¼ 50 EHV 4-350/90/DA /8 14 UNF G 1¼ 50 EHV 5-350/90/DA /8 14 UNF G 1¼ 50 EHV 6-350/90/DA /8 14 UNF G 1¼ 50 EHV /90/DA /8 14 UNF G 1¼ 50 Ø d Ø D Ø G Ø E F O'Ring B C A Above dimensions are in mm and are subject to manufacturing tolerances. 33 Parker Hannifin
34 Diaphragm Accumulators General Information Diaphragm Accumulator Operation of the Olaer gas loaded diaphragm accumulator is based on the considerable difference in compressibility between a gas and a liquid, enabling a large quantity of energy to be stored in an extremely compact form. This enables a liquid under pressure to be accumulated, stored and recovered at any time. The adaptation of a hydraulic shock absorber made up of a diaphragm accumulator improves driver comfort and offers immediate response times when driving over obstacles and the same flexibility for variable operating conditions. 0 < speed < 50 kph 3.5 < load variation < 100% Identical flexibility depending on your use. The same EC pressure directive (PED) compliant accumulator can be used in over 35 destination countries, thus facilitating their free movement. The technical characteristics are as follows: Minimum/maximum temperature allowable ( Celsius) : - 20/+80 for standard nitrile elastomers for models Litre - 10/+80 for standard nitrile elastomers for models 2 Litres - 35/+80 for hydrin elastomers Materials : carbon steel or stainless steel, nitrile or hydrin diaphragm, for other constructions: consult Parker Olaer. P 0 V 0 A P 1 V 1 B P 2 V 2 C V V0 = Capacity in nitrogen of the accumulator V1 = Gas volume at the minimum hydraulic pressure V2 = Gas volume at the maximum hydraulic pressure V = Returned and/or stored volume of working fluid between P1 and P2 P0 = Initial preload of the accumulator P1 = Gas pressure at the minimum hydraulic pressure P2 = Gas pressure at the maximum hydraulic pressure A - The diaphragm is in the Pre-charge position, which means that it is only filled with nitrogen. The knob closes the hydraulic orifice and prevents the destruction of the diaphragm. B - Position at the minimum operating pressure : there must be a certain amount of fluid between the diaphragm and the hydraulic orifice, such that the knob does not close the hydraulic orifice. Thus, P0 must always be < P1. C - Position at the maximum operating pressure: the volume change V between the minimum and maximum positions of the operating pressures represents the fluid quantity stored. 34 Parker Hannifin
35 Diaphragm Accumulators ELM Series: How to order a Diaphragm accumulator Series Volume Max. working pressure (PS) Regulation code Form Execution Construction Nitrogen gas Pre-charge ELM /85 A F Po=90b ELM diaphragm accumulators. in Litres in Bar 00 : According to the PED, article : SELO Approval only 0.32 to 1 L 88 : SELO & CE approvals for volumes greater than 1 L A : internal threaded C : internal threaded external threaded F : Standard (nitrogen rechargeable) G : Request (Pre-charged with nitrogen in factory) 011** : Carbon steel 019** : Stainless steel ***25 : NBR nitrile standard rubber ***02 : ECO Hydrin rubber Other fluids and temperatures, contact Parker Olaer. in Bar at 20 C Form A Form C F standard execution Nitrogen rechargeable G execution at request Nitrogen pre-charged in factory Other connection on request. 35 Parker Hannifin
36 Diaphragm Accumulators ELM Series BAR, to 1.4 Litres Standard Version (steel casing/mix NBR) for mineral oils temperature from - 20 up to 80 C According to PED 97/23/EC, Fluid Group 2 and SELO s, Accessories Dimensions Pre-charge Clamps (quantity) ELM /00/AF* ELM /00/AF* ELM /85/AF* ELM /85/AF* ELM /85/CF* ELM /85/AF* ELM /85/CF* ELM /85/AF* ELM /85/CF* ELM 1-210/85/AF* ELM 1-210/85/CF* ELM /88/AF ELM /88/CF ELM /88/AF ELM /88/CF * According to the PED, article E95 (1) E106 (1) E106 (1) E114 (1) E114 (1) E136 (1) E136 (1) E136 (1) E136 (1) E155 (1) E155 (1) E155 (1) E155 (1) Parker Hannifin
37 Diaphragm Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Execution form Max. Precharge Max compression in ratio P2/P0 Max Pressure amplitude P2/P1 Weight kg Dimensions in mm A max Height Oilport B SW D G F H Lock Nut type ELM /00/AF* AF G½ - - ELM /00/AF* AF G½ - - ELM /85/AF* AF G½ - - ELM /85/AF* AF G½ - - ELM /85/CF* CF G½ M33x1.5 M33 ELM /85/AF* AF G½ - - ELM /85/CF* CF G½ M33x1.5 M33 ELM /85/AF* AF G½ - - ELM /85/CF* CF G½ M33x1.5 M33 ELM 1-210/85/AF* AF G½ - - ELM 1-210/85/CF* CF G½ M33x1.5 M33 ELM /88/AF AF G½ - - ELM /88/CF CF G½ M33x1.5 M33 ELM /88/AF AF G½ - - ELM /88/CF CF G½ M33x1.5 M33 Form A Form C F standard execution G execution at request Nitrogen rechargeable Nitrogen pre-charged in factory See drawing page 35 Above dimensions are in mm and are subject to manufacturing tolerances. Other connection on request. 37 Parker Hannifin
38 Diaphragm Accumulators ELM Series BAR, 0.75 to 3.5 Litres Standard Version (steel casing mix NBR) for mineral oils and for volume 1.4 L temperature from - 20 up to 80 C for volume 2 L temperature from - 10 C up to 80 C. According to PED 97/23/CE, Fluid Group 2 and SELO s, Accessories Dimensions ELM /88/AF Pre-charge 1 to 109 Clamps (quantity) E155 (1) ELM /88/CF ELM /88/AF ELM /88/CF ELM 2-100/88/AF ELM 2-250/88/AF ELM 2-350/88/AF ELM 2-350/88/CF ELM /88/AF ELM /88/AF ELM /88/CF ELM /88/AF ELM /88/AF ELM /88/CF ELM /88/CF** E155 (1) E155 (1) E155 (1) E155 (1) E155 (1) E180 (1) E180 (1) E168 (1) E180 (1) E180 (1) E168 (1) E180 (1) E180 (1) E136 (1)** ** According to PED, article 3.3 and stainless steel construction 38 Parker Hannifin
39 Diaphragm Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Execution form Max. Precharge Max compression in ratio P2/P0 Max Pressure amplitude P2/P1 Weight kg Dimensions in mm A max Height Oilport B SW D G F H Lock Nut type ELM /88/AF AF G½ - - ELM /88/CF CF G½ M33x1.5 M33 ELM /88/AF AF G½ - - ELM /88/CF CF G½ M33x1.5 M33 ELM 2-100/88/AF AF G½ - - ELM 2-250/88/AF AF G¾ - - ELM 2-350/88/AF AF G¾ - - ELM 2-350/88/CF CF G¾ M45x1.5 M45 ELM /88/AF AF G¾ - - ELM /88/AF AF G¾ - - ELM /88/CF CF G¾ M45x1.5 M45 ELM /88/AF AF G¾ - - ELM /88/AF AF G¾ - - ELM /88/CF CF G¾ M45x1.5 M45 ELM /88/CF** CF G½ - - See drawing page 35 Above dimensions are in mm and are subject to manufacturing tolerances. 39 Parker Hannifin
40 Diaphragm Accumulators ELM Series BAR, to 3.5 Litres ECO Version (steel casing/mix ECO) for mineral oils temperature from - 35 C up to 80 C According to PED 97/23/EC, Fluid Group 2 and SELO s, Accessories Dimensions Pre-charge Clamps (quantity) ELM /00/AF* ELM /00/AF* ELM /85/AF* ELM /85/AF* ELM /85/CF* ELM /85/AF* ELM /85/CF* ELM /85/AF* ELM /85/CF* ELM 1-210/85/AF* ELM 1-210/85/CF* ELM /88/AF ELM /88/CF ELM /88/AF ELM /88/CF E95 (1) E106 (1) E106 (1) E114 (1) E114 (1) E114 (1) E114 (1) E136 (1) E136 (1) E155 (1) E155 (1) E155 (1) E155 (1) * according to the PED, article Parker Hannifin
41 Diaphragm Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Execution form Max. Precharge Max compression in ratio P2/P0 Max Pressure amplitude P2/P1 Weight kg Dimensions in mm A max Height Oilport B SW D G F H Lock Nut type ELM /00/AF* AF G½ - - ELM /00/AF* AF G½ - - ELM /85/AF* AF G½ - - ELM /85/AF* AF G½ - - ELM /85/CF* CF G½ M33x1.5 M33 ELM /85/AF* AF G½ - - ELM /85/CF* CF G½ M33x1.5 M33 ELM /85/AF* AF G½ - - ELM /85/CF* CF G½ M33x1.5 M33 ELM 1-210/85/AF* AF G½ - - ELM 1-210/85/CF* CF G½ M33x1.5 M33 ELM /88/AF AF G½ - - ELM /88/CF CF G½ M33x1.5 M33 ELM /88/AF AF G½ - - ELM /88/CF CF G½ M33x1.5 M33 Form A Form C F standard execution G execution at request Nitrogen rechargeable Nitrogen pre-charged in factory See drawing page 35 Above dimensions are in mm and are subject to manufacturing tolerances. Other connection on request. 41 Parker Hannifin
42 Diaphragm Accumulators ELM Series BAR, 1.4 to 3.5 Litres ECO Version (steel casing/mix ECO) for mineral oils temperature from - 35 C up to 80 C According to PED 97/23/EC, Fluid Group 2 and SELO s, Accessories Dimensions ELM /88/AF Pre-charge 1 to 109 Clamps (quantity) E155 (1) ELM /88/CF ELM /88/AF ELM /88/CF ELM 2-100/88/AF ELM 2-250/88/AF ELM 2-350/88/AF ELM 2-350/88/CF ELM /88/AF ELM /88/AF ELM /88/CF ELM /88/AF ELM /88/AF ELM /88/CF E155 (1) E155 (1) E155 (1) E155 (1) E155 (1) E180 (1) E180 (1) E168 (1) E180 (1) E180 (1) E168 (1) E180 (1) E180 (1) Parker Hannifin
43 Diaphragm Accumulators Effective Gas vol. Litres Max. Working pressure (PS) Execution form Max. Precharge Max compression in ratio P2/P0 Max Pressure amplitude P2/P1 Weight kg Dimensions in mm A max Height Oilport B SW D G F H Lock Nut type ELM /88/AF AF G½ - - ELM /88/CF CF G½ M33x1.5 M33 ELM /88/AF AF G½ - - ELM /88/CF CF G½ M33x1.5 M33 ELM 2-100/88/AF AF G½ - - ELM 2-250/88/AF AF G¾ - - ELM 2-350/88/AF AF G¾ - - ELM 2-350/88/CF CF G¾ M45x1.5 M45 ELM /88/AF AF G¾ - - ELM /88/AF AF G¾ - - ELM /88/CF CF G¾ M45x1.5 M45 ELM /88/AF AF G¾ - - ELM /88/AF AF G¾ - - ELM /88/CF CF G¾ M45x1.5 M45 Form A Form C F standard execution G execution at request Nitrogen rechargeable Nitrogen pre-charged in factory See drawing page 35 Other connection on request. Above dimensions are in mm and are subject to manufacturing tolerances. 43 Parker Hannifin
44 Regulations Regulations for High and Low pressure Bladder Accumulators Regulations available from Parker Olaer. Designation EUROPE USA CHINA CANADA AUSTRALIA /90 /90 /90 /15 /48 /88 /92 /83 /91 s* Approvals* CE Fluid Group 2 CE Fluid Group 1 ATEX EX Max. Working Pressure ASME VIII div 1 Max. Working Pressure Psi () SELO Max. Working Pressure CRN Max. Working Pressure Psi () AS1210 Max. Working Pressure EBV 0.5 L x x x 40 EBV 0.5 L x x x 50 EBV 1 to 5 L x x x 40 x 40 EBV 1 to 5 L x x x 80 x 80 EBV 10 to 50 L x x 16 EBV 10 to 50 L x x x 40 On request 580 (40) EBV 100 to 200 L x x 16 EBV 100 to 200 L x x x 20 x 20 EBV 100 to 200 L x x x 40 x 40 EBV 100 to 200 L x x 50 EBV 100 to 575 L x x x 8 EBV 100 to 575 L x x 10 EBV 100 to 575 L x x 15 EBV 100 to 575 L x x x 16 EBV 100 to 575 L x x x 20 EBV 100 to 575 L x x x 40 EHV 0,5L x x x 350 x 350 EHV 1 to 5 L x x x 300 x 300 EHV 1 to 5 L x x x 350 x 350 On request 350 EHV 1 to 5 L x x x 690 x 690 EHV 2.5L to 5 L x x x 120 x 120 EHV L x x x 210 x 210 EHV L x x x 350 On request 4000 (276 Bar) x 350 On request 320 EHV 4 to 60 L On request 5000 (345 Bar) EHV 4 to 60 L On request 6000 (413 Bar) EHV 10 to 42 L On request 3000 (207 Bar) x 3000 (207 Bar) EHV 10 to 42 L On request 3600 (248 Bar) x 3600 (248 Bar) EHV 10 to 42 L On request 4000 (276 Bar) x 4000 (276 Bar) EHV 10 to 50 L x x x 690 x 690 EHV 10 to 57 L On request 3600 (248 Bar) On request 248 EHV 10 to 57 L On request 4000 (276 Bar) On request 276 EHV 10 to 57 L x x 480 x 480 On request 480 EHV 10 to 60 L x x x 300 On request 3000 (207 Bar) x 300 EHV 10 to 60 L x x x 330 On request 3600 (248 Bar) x 330 EHV 10 to 60 L x x x 480 x 480 EHV 50 to 57L On request 3000 (207 Bar) x 3000 (207 Bar) EHV 50 to 57 L On request 3600 (248 Bar) x 3600 (248 Bar) EHV 50 to 57 L On request 4000 (276 Bar) x 4000 (276 Bar) EHV 100 to 200 L x x 300 x 300 EHVF 2.5 to 10 L x x 350 x 350 EHVF 10 to 50 L x x 250 x 250 EHVF 10 to 50 L x x 330 x 330 Multi Approvals are possible Codification Regulation 90 EX CE+atex 94 CE+ASME 88 CE+SELO 86 CE+ASME+SELO For others regulations contact Parker Olaer. 44 Parker Hannifin
45 Regulations BRASIL RUSSIA MARINE - OFFSHORE Designation /AA /AE /AM /71 /AU /24 /11 /41 NR13 Max. Working Pressure GOST R Max. Working Pressure DNV Mobile ships Bureau Veritas Marine ABS American Bureau of Shipping Max. Working Pressure Approvals* s* x EBV 0.5 L x EBV 0.5 L x EBV 1 to 5 L x EBV 1 to 5 L x EBV 10 to 50 L x EBV 10 to 50 L x EBV 100 to 200 L x EBV 100 to 200 L on request x EBV 100 to 200 L x EBV 100 to 200 L x 8 8 EBV 100 to 575 L x EBV 100 to 575 L x EBV 100 to 575 L x EBV 100 to 575 L x EBV 100 to 575 L x EBV 100 to 575 L x x x 350 EHV 0,5L 300 EHV 1 to 5 L x x x x 350 EHV 1 to 5 L x EHV 1 to 5 L x EHV 2.5L to 5 L x EHV L x x x x 350 EHV L x EHV 4 to 60 L x EHV 4 to 60 L x EHV 10 to 42 L x EHV 10 to 42 L x 276 on request 276 EHV 10 to 42 L x EHV 10 to 50 L x EHV 10 to 57 L x EHV 10 to 57 L x EHV 10 to 57 L x EHV 10 to 60 L x x x x 330 EHV 10 to 60 L x EHV 10 to 60 L x EHV 50 to 57L x EHV 50 to 57 L x EHV 50 to 57 L x EHV 100 to 200 L x EHVF 2.5 to 10 L x 330 on request 330 EHVF 10 to 50 L x EHVF 10 to 50 L This table is giving an indication of approval avalaibality for the range of products. Availability is to be confirmed for each approval, in particular the pressure rating and the allowable working temperatures. 45 Parker Hannifin
46 Internal & External Protection Internal & External Protections Protections available from Parker Olaer. Additionnal options for standard for bladder accumulators. Calculation Example Base Price Add for change of protection Total cost for this special Complete Accumulator: 4 liter complete accumulator with protection Rilsan 85 x (from page 20) x x EPOXY 80 microns NICKEL PLATING 50 microns RILSAN microns Valve Stem, Fluid port, Anti Extrusion Ring and Protection Cap Internal Stainless Steel Internal/External Stainless Steel Internal/External Stainless Steel Internal/External Standard Steel Codes Volume All prices below are in addition (on top of) the standard construction carbon steel 11 on top of the complete base, accumulator cost when ordered complete as a bladder accumulator with special characteristics. 0,2 x x x x 0,5 x x x x 1 x x x x 1,6 x x x x 2,5 x x x x 4 x x x x 5 x x x x 6 x x x x DIA 168 x x x x DIA 221 x x x x 12 x x x x 20 x x x x 24,5 x x x x 32 x x x x 42 x x x x 50 x x x x This is showing the options, prices are available on request 57 x x x x 100 x x x x 200 x x x x Depending on your application, fluid and the environment in which you install your systems/equipment, Parker can offer a variety of internal and external shell coatings for your bladder accumulator. Please contact our technical support or your local accumulator expert if you are uncertain what you may require or for more details on the various coatings. 46 Parker Hannifin
47 Bladder Mixes Bladder Mixes Bladder mixes available from Parker Olaer. Additionnal options over standard for bladder accumulators series EHV/EBV. Calculation Example EHV Base Price add for change of mix Complete Accumulator: 4 liter complete accumulator with mix 80 (viton) bladder x (from page 20) x x Spare Bladder Kit: 4 liter spare bladder mix 80 (viton) bladder x (from page 20) x x Total cost for this special Standard Bladder For other bladder mixes as spare parts, start with the cost for NBR, Mix 25 and add the adder prices listed below. For complete accumulators with special bladders, start with the base cost of a standard accumulators and then add the additional cost listed below. Mix Number Mix 25 Mix 02 Mix 10 Mix 20 Mix 30 Mix 35 Mix 37 Mix 40 Mix 47 Mix 80 Mix Name Standard NBR (Nitrile) Hydrin C Low Temp Nitrile Heavy Duty Nitrile Nitrile High Temp Nitrile Extreme Low Temp Nitrile Butyl EPDM Viton Max Temp C Min Temp C Typical Fluid Volume Mineral Oil Mineral Oil Mineral Oil Mineral Oil Special fuels (not unleaded gasoline) Mineral Oil Consult Parker Olaer regarding fluid and application Water based fluids Phosphate esters Aggressive fluids All prices below are in addition (on top of) the base Mix 25 bladder kit cost(spares) or on top of the complete base, Mix 25 accumulator cost when ordered complete as a bladder accumulator with special bladder mix. 0,2 x x x x x x x x 0,5 x x x x x x x x x 1 x x x x x x x x x 1,6 x x x x x x x x x 2,5 x x x x x x x x x 4 x x x x x x x x x 5 x x x x x x x x x 6 x x x x x x x x x DIA 168 x x x x x x x x x DIA 221 x x x x x x x x x 12 x x x x x x x x x 20 x x x x x x x x x 24,5 x x x x x x x x x 32 x x x x x x x x x 42 x x x x x x x x x 50 x x x x x x x x x 57 x x x x x x x x x 100* x x x x x x x x 200* x x x x x x x x * Accumulators 100 & 200 Litres Standard Nitrile Mix 20 This is showing the options, prices are available on request 47 Parker Hannifin
48 Accessories Clamps Clamps : Steel with zinc plated protection, Rubber EPDM (Version 48), Rubber NBR Nitrile (Version 25) s, Dimensions Design RECOMMENDED Min to Max TIGHTENING ɸ mm A E E E E E E E E D D D E 54 to 56 E 87 to 97 E 99 to 109 E 112 to 124 E 128 to 138 E 146 to 157 E 155 to 165 E 166 to to 184 E 215 to 219 D D 219 to 226 D 363 to Parker Hannifin
49 D J Catalogue HY /UK Accessories A B Min C Max Dimensions in mm D E F G H I J K Recommended tightening torque N.m Recommended max allowable weight if vertical equipment kg Recommended max allowable weight if horizontal equipment kg A M10x E M8x E M8x E M8x E M8x E M10x E M10x E M10x E M10x D M12x D M12x D M12x Shape D I Shape E A B Ø SERRAGE/TIGHTENING Tightening Ø Tightening F C MINI C MAXI K G E H 49 Parker Hannifin
50 Accessories Support Brackets CE CE CE159A s Accumulators 1 to 5 Litres EHV 4 & 6 & 10 Litres Accumulators 10 to 50 Litres < 550 Bar Mounting Frames EF EF EF For s EHV EHV 4 & 6 & 10 Litres EHV 10 & 12 & 20 & 24.5 Litres EHV 32 & 50 Litres 50 Parker Hannifin
51 Accessories Design Dimensions in mm A B C H I J K L M N R S Weight in kg CE89 A CE108 A CE159A B Shape A View following F F Shape B View following F F Dimensions in mm A B C D E F G H J EF EF EF Parker Hannifin
52 Accessories Charging Set VGU The charging set VGU is an indispensable instrument for the verification, pressurization and nitrogen bleeding of most of the hydraulic accumulators available on the market. The standard set is delivered in a storage case containing the following: VGU universal tester and pressurizer (end M28 x 1.50). Pressure gauge kit from 0 to 25. Pressure gauge kit from 0 to 250. Connection adapters for inflation valves (7/8 5/8 8V1 - M28 x 1.50). High pressure hose, 2.5 m long, for connecting to a nitrogen source. Hexagon socket screw key 6mm. Jackets of replacement joints. Operating instruction in French, English, German. Note: On request, the following options are available: Pressure gauge kits with different scale divisions: 63mm with glycerol bath back end G1/4 cyl. equipped with direct gear for Minimess connection. Scale divisions 0-10, 0-60, 0-100, 0-400, with accuracy class 1.6%. High pressure hose of different length with adapters for nitrogen bottles from various countries (specify country), at each end with a female swivel coupling G1/4 for connecting to the inflation port. Maximum working pressure: limited by the maximum operating pressure of the installed hydraulic system, pressure limited to 400 in any case. Spare Parts Spare Parts Spare Parts High Pressure Hose Spare Part Kits Gauge Kit VGU Adaptors VGU VGU/F.25/250.8.TS2.3 TS2 (France) 0 to 25 Adaptor 7/8-14 UNF VGU/F.25/250.8.TS TS3 (Germany) to Adaptor 5/8-18 UNF VGU/F.25/250.8.TS TS8 (Italy) to Coupling 8 V VGU/F.25/250.8.TS TS9 (Netherlands) Adaptor 7/8-14 UNF VGU/F.25/400.8.TS TS2 (France) Adaptor 1/4 cyl VGU/F.25/400.8.TS VGU/F.25/400.8.TS TS3 (Germany) TS8 (Italy) Raccord direct de manomètre Direct connection pressure gauge coupling Direkter anschluss des manometers Option: Selon pays Option: According countries Option: In versch. landern VGU/F.25/400.8.TS TS9 (Netherlands) Manomètre Pressure gauge Manometer VGU Flexible haute pression High Pressure Hose Hochdruckschlauch How to order a VGU Charging set: see page 54 Raccordement direct sur valve accumulateur ø M28 x 1.50 avec vis 6 pans creux 6S/p. Direct connection to M28 dia x 1.50 accumulator valve with 6 mm A/F Hexagonal socket - head screw Direkter anschluss an speicher-ventil ø M28 x 1.50 mit inbusschraube M6 Raccordement sur source d azote Connection to nitrogen source Anschluss an stickstoffflasche Adaptateur long Long adapter Lange adapter 7/8-14 UNF Adaptateur court Short adapter Kurz adapter 7/8-14 UNF Adaptateur / adapter 5/8-18 UNF Adaptateur / adapter 5/8-18 UNF Jeu d adaptateurs Set of adapters Adaptersatz Raccord / coupling Adapter 8 V1 - VG 8 52 Parker Hannifin
53 Accessories Charging Set VG3 The charging set VG3 is an indispensable instrument for the verification, pressurization and nitrogen bleeding of the hydraulic accumulators. The standard set is delivered in a storage case containing the following: pressure gauge with standardized graduations in vent valve 3 connection adapters for charging valves. (7/8 5/8-8V1). High pressure hose, 2.5 m length, in standard, maximum working pressure 400 Bar. This hose is fitted at each end with a female swivel coupling G ¼ BSP for connecting to the inflation port. It can be connected to a commercial nitrogen bottles, in this case add an adapter on one end view model in the country. For the other destinations consult Parker Olaer. Operating instruction french/english version Note: On request, the following options are available : Pressure gauge with different scale divisions : 63 mm with glycerol bath back end G1/4 BSP equipped with direct gear for minimess connection. To scale divisions 0-10,0-60,0-100,0-400, with accuracy class 1.6%. High pressure hose of different length with adapters for nitrogen bottles from various countries are available (specify country) Maximum working pressure: limited by the maximum operating pressure of the installed hydraulic system, pressure limited to 400 in any case. VG3 6 1 TS2 1 Spare Parts Gauge Kit High Pressure Hose Spare Part Kits 0 to 6 Spare Parts Adaptors VG3 Adaptor 5/8-18 UNF VG TS to Adaptor 7/8-14 UNF VG TS to Coupling 8 V VG TS to VG TS to VG TS to Manometre Pressure Gauge How to order a VG3 Charging set: see page 54 Flexible Haute Pression High Pressure Hose L : 2,5 M Raccordement sur soucre d azote Connection to nitrogen source Jeu d adaptateurs Set of adapters 53 Parker Hannifin
54 Accessories How to order a VGU Charging Set Pressure Gauges Connection valve stem High Pressure Hose VGU/F 25/250 8 TS2 3 Conditioning of Charging Set 25/250 25/400 8 : 7/8-14 UNF (short) 7/8-14 UNF (lenght) 5/8-18 UNF 8V1 G 1/4 gas cyl. TS2 : connection for French bottle TS3 : connection for German bottle TS8 : connection for Italian bottle TS9 : connection for Netherlands bottle For other connections : consult Parker Olaer 3: Plastic Box How to order a VG3 Charging Set Pressure Gauges Connection valve stem High Pressure Hose VG TS2 1 Conditioning of Charging Set : 7/8-14UNF 5/8-18 UNF 8 V 1 TS2: Connection for French Bottle 1: Plastic Box 54 Parker Hannifin
55 Accessories Safety Blocks Parker Olaer has developed a complete range of decompressing and isolating blocks (sizes 10 to 50) to answer all standard and special applications. These blocks are in conformity with the European Directive on the equipment under pressure (97/23), these appliances have been designed to group together in a single compact unit all the components necessary for the correct operation of a hydraulic system equipped with hydropneumatic accumulators. In the E version, the basic block, to decompress the accumulator, can be equipped with an electro-valve : 2 ways 2 positions (DI 10/DI 20/DI 32) cartridge type. 3 ways 2 positions (DI 16/DI 24) with impact of connection according to DIN Form A, ISO 4401 and CETOP RP 121 H. The basic block consists of : Isolating valve to isolate the accumulator from the circuit for all the blocks except from model DI 10 where it also ensures the decompression function. A drain valve for decompressing the accumulator for all models (except DI 10) A pressure limiting valve EC with poppet calibrated generally to the maximum service pressure of the accumulator (under no circumstances must this appliance be used to protect the hydraulic pump) Pressure tapping port (M) DI Series: How to order a Safety Block Nominal size in mm Discharge valve Flow Control valve Connection Accumulator side Adjusting Pressure of relief valve en Approval of relief valve DI 24 EY S C Seals Material V Electro-valve tension 230 V 50/60 DI 10, 16, 20, 24, 32 M: Manual EY: Electrical, normally open (all models) EX: Electrical, normally closed (DI10/DI20/DI32) S: Without R: With limitor (consult Parker Olaer) O: Without connection * Other connections: consult page 9 Standard: 40/80/100/210/250/330/350 Other Value: consult Parker Olaer C: with EC approvement B: for glycol water Butyl (IIR) E: for skydrol Ethylene - Propylene (EPDM) H: minerals oils Perbunan (NBR) V: all fluids except skydrol Viton (FPM) 00: without electro-valve 24VDC 230V50/60 Other tensions: consult Parker Olaer 55 Parker Hannifin
56 Accessories Safety Block DI 10 Manual Version Standard version (Carbon steel, rings NBR) temperature -10 C up to 70 C Maximum working pressure : 400 Bar According to PED 97/23/EC s Connecting to accumulator EHV 0.5 to 1.6 L G3/4* DI10MS/2/350CH * Y01 EHV 10 to 50 L G2" DI10MS/3/330CH * J01 ELM G1/2" DI10MS/4/100CH D01 ELM G1/2" DI10MS/4/140CH Q01 ELM G1/2" DI10MS/4/210CH G01 ELM G1/2" DI10MS/4/250CH H01 ELM G1/2" DI10MS/4/330CH J01 ELM G1/2" DI10MS/4/350CH Y01 ELM 0, G1/2" DI10MS/5/210CH G01 ELM 0, /0, G1/2" DI10MS/5/250CH H01 ELM G3/4" DI10MS/6/100CH D01 ELM G3/4" DI10MS/6/140CH Q01 ELM G3/4" DI10MS/6/210CH G01 ELM G3/4" DI10MS/6/250CH H01 ELM G3/4" DI10MS/6/330CH J01 ELM G3/4" DI10MS/6/350CH Y01 * without electro-valve Safety Block DI 10 Electrical Version Standard version (Carbon steel, rings NBR) temperature -10 C up to 60 C Maximum working pressure : 350 Bar According to PED 97/23/EC s Connecting to accumulator With Electro-valve tension 24VDC With Electro-valve tension 230V50/60 EHV 2.5 to 10 L (long) G1 1/4* DI10EYS/1/350CH24VCC Y21 DI10EYS/1/350CH230V50/ Y61 EHV 0.5 to 1.6 L G3/4* DI10EYS/2/350CH24VCC Y21 DI10EYS/2/350CH230V50/ Y61 ELM G1/2" DI10EYS/4/100CH24VCC D21 DI10EYS/4/100CH230V50/ D61 ELM G1/2" DI10EYS/4/140CH24VCC Q21 DI10EYS/4/140CH230V50/ Q61 ELM G1/2" DI10EYS/4/210CH24VCC G21 DI10EYS/4/210CH230V50/ G61 ELM G1/2" DI10EYS/4/250CH24VCC H21 DI10EYS/4/250CH230V50/ H61 ELM G1/2" DI10EYS/4/330CH24VCC J21 DI10EYS/4/330CH230V50/ J61 ELM G1/2" DI10EYS/4/350CH24VCC Y21 DI10EYS/4/350CH230V50/ Y61 ELM 0.32 to 210 G1/2" DI10EYS/5/210CH24VCC G21 DI10EYS/5/210CH230V50/ G61 ELM to 250/0.16 to 250 G1/2" DI10EYS/5/250CH24VCC H21 DI10EYS/5/250CH230V50/ H61 ELM G3/4" DI10EYS/6/100CH24VCC D21 DI10EYS/6/100CH230V50/ D61 ELM G3/4" DI10EYS/6/140CH24VCC Q21 DI10EYS/6/140CH230V50/ Q61 ELM G3/4" DI10EYS/6/210CH24VCC G21 DI10EYS/6/210CH230V50/ G61 ELM G3/4" DI10EYS/6/250CH24VCC H21 DI10EYS/6/250CH230V50/ H61 ELM G3/4" DI10EYS/6/330CH24VCC J21 DI10EYS/6/330CH230V50/ J61 ELM G3/4" DI10EYS/6/350CH24VCC Y21 DI10EYS/6/350CH230V50/ Y61 Options or Accessories Characteristics RELIEF VALVE CE 100 BAR RELIEF VALVE CE 140 BAR RELIEF VALVE CE 210 BAR RELIEF VALVE CE 250 BAR RELIEF VALVE CE 330 BAR RELIEF VALVE CE 350 BAR Parker Hannifin
57 Accessories Safety Block DI 16 Manual Version Standard version (Carbon steel, rings NBR) temperature -15 C up to 80 C Maximum working pressure : 350 Bar According to PED 97/23/EC s Connecting to accumulator EHV 0,5 up to 1,6 L G3/4" DI16MS/2/210 CV G02 EHV 0,5 up to 1,6 L G3/4" DI16MS/2/250 CV H02 EHV 0,5 up to 1,6 L G3/4" DI16MS/2/330 CV J02 EHV 0,5 up to 1,6 L G3/4" DI16MS/2/350 CV Y02 EHV 2,5 up to 10 L G1"1/4 DI16MS/1/210 CV G02 EHV 2,5 up to 10 L G1"1/4 DI16MS/1/250 CV H02 EHV 2,5 up to 10 L G1"1/4 DI16MS/1/330 CV * J02 EHV 2,5 up to 10 L G1"1/4 DI16MS/1/350 CV * Y02 EHV 10 up to 50 L G2" DI16MS/3/210 CV G02 EHV 10 up to 50 L G2" DI16MS/3/250 CV H02 EHV 10 up to 50 L G2" DI16MS/3/330 CV * J02 EHV 10 up to 50 L G2" DI16MS/3/350 CV Y02 * without electro-valve Safety Block DI 16 Electrical Version Standard version (Carbon steel, rings FKM) temperature -15 C up to 60 C Maximum working pressure : 350 Bar According to PED 97/23/EC s Connecting to accumulator With Electro-valve tension 24VDC EHV 0,5 up to 1,6 L G3/4" DI16EYS/2/210 CV G02 EHV 0,5 up to 1,6 L G3/4" DI16EYS/2/250 CV H02 EHV 0,5 up to 1,6 L G3/4" DI16EYS/2/330 CV J02 EHV 0,5 up to 1,6 L G3/4" DI16EYS/2/350 CV Y02 EHV 2,5 up to 10 L G1"1/4 DI16EYS/1/210 CV G02 EHV 2,5 up to 10 L G1"1/4 DI16EYS/1/250 CV H02 EHV 2,5 up to 10 L G1"1/4 DI16EYS/1/330 CV J02 EHV 2,5 up to 10 L G1"1/4 DI16EYS/1/350 CV Y02 EHV 10 up to 50 L G2" DI16EYS/3/210 CV G02 EHV 10 up to 50 L G2" DI16EYS/3/250 CV H02 EHV 10 up to 50 L G2" DI16EYS/3/330 CV J02 EHV 10 up to 50 L G2" DI16EYS/3/350 CV Y02 Options or Accessories Electro valve tension ELECTRO-VALVE T3 24 VCC ELECTRO-VALVE T3 110/120VA 50/60 Hz ELECTRO-VALVE T3 220/230VA 50/60 Hz REGULATION BLOCK R FLANGE M 3/4" GAS CYL Connection Accumulator Side FLANGE M 1''1/4 GAS CYL Connection Accumulator Side FLANGE M 2" GAS CYL Connection Accumulator Side RELIEF VALVE CE RELIEF VALVE CE RELIEF VALVE CE RELIEF VALVE CE Parker Hannifin
58 Accessories Safety Block DI 20 Manual Version Standard version (Carbon steel, rings NBR) temperature -10 C up to 70 C Maximum working pressure : 400 Bar According to PED 97/23/EC s Connecting to accumulator EHV 2,5 up to 10 L G1"1/4 DI20MS/1/350CH Y01 EHV 10 up to 50 L G2" DI20MS/3/330CH J01 Safety Block DI 20 Electrical Version Standard version (Carbon steel, rings NBR) temperature -10 C up to 60 C Maximum working pressure : 350 Bar According to PED 97/23/EC s Connecting to accumulator With Electro-valve tension 24VDC With Electro-valve tension 230V5/60 EHV 2,5 up to 10 L G1"1/4 DI20EYS/1/350CH24VCC Y21 DI20EYS/1/350CH230V50/ Y61 EHV 10 up to 50 L G2" DI20EYS/3/210CH24VCC G21 DI20EYS/3/210CH230V50/ G61 EHV 10 up to 50 L G2" DI20EYS/3/250CH24VCC H21 DI20EYS/3/250CH230V50/ H61 EHV 10 up to 50 L G2" DI20EYS/3/330CH24VCC J21 DI20EYS/3/330CH230V50/ J61 EHV 10 up to 50 L G2" DI20EYS/3/350CH24VCC Y21 DI20EYS/3/350CH230V50/ Y61 Options or Accessories Characteristics RELIEF VALVE CE 210 BAR RELIEF VALVE CE 250 BAR RELIEF VALVE CE 330 BAR RELIEF VALVE CE 350 BAR Parker Hannifin
59 Accessories Safety Block DI 24 Manual Version Standard version (Carbon steel, rings FKM) temperature -15 C up to 80 C Maximum working pressure : 350 Bar According to PED 97/23/EC s Connecting to accumulator EHV 2,5 up to 10 L G1"1/4 DI24MS/1/330CV J02 EHV 2,5 up to 10 L G1"1/4 DI24MS/1/350CV Y02 EHV 10 up to 50 L G2" DI24MS/3/210CV G02 EHV 10 up to 50 L G2" DI24MS/3/250CV * H02 EHV 10 up to 50 L G2" DI24MS/3/330CV * J02 ACCU PISTON 10 up to 50 L G2"&EBV 100 and 200 L Consult Parker Olaer * without electro-valve Safety Block DI 24 Electrical Version Standard version (Carbon steel, rings FKM) temperature -15 C up to 60 C Maximum working pressure : 350 Bar According to PED 97/23/EC s Connecting to accumulator With Electro-valve tension 24VDC EHV 2,5 up to 10 L G1"1/4 DI24EYS/1/210CV G02 EHV 2,5 up to 10 L G1"1/4 DI24EYS/1/250CV H02 EHV 2,5 up to 10 L G1"1/4 DI24EYS/1/330CV J02 EHV 2,5 up to 10 L G1"1/4 DI24EYS/1/350CV Y02 EHV 10 up to 50 L G2" DI24EYS/3/210CV G02 EHV 10 up to 50 L G2" DI24EYS/3/250CV H02 EHV 10 up to 50 L G2" DI24EYS/3/330CV J02 PISTON ACCUMULATOR 10 up to 50 L G2"&EBV 100 and 200 L Consult Parker Olaer Options or Accessories Electro valve tension ELECTRO-VALVE T3 24 VCC ELECTRO-VALVE T3 110/120 V 50/60 Hz ELECTRO-VALVE T3 220/230 V 50/60 Hz REGULATION BLOCK R FLANGE M 1"1/4 GAZ CYL CONNECTION ACCUMULATOR SIDE FLANGE M 2" GAZ CYL CONNECTION ACCUMULATOR SIDE RELIEF VALVE CE 210 BAR RELIEF VALVE CE 250 BAR RELIEF VALVE CE 330 BAR RELIEF VALVE CE 350 BAR Parker Hannifin
60 Parker Worldwide Europe, Middle East, Africa AE United Arab Emirates, Dubai Tel: [email protected] AT Austria, Wiener Neustadt Tel: +43 (0) [email protected] AT Eastern Europe, Wiener Neustadt Tel: +43 (0) [email protected] AZ Azerbaijan, Baku Tel: [email protected] BE/LU Belgium, Nivelles Tel: +32 (0) [email protected] BY Belarus, Minsk Tel: [email protected] CH Switzerland, Etoy Tel: +41 (0) [email protected] CZ Czech Republic, Klecany Tel: [email protected] DE Germany, Kaarst Tel: +49 (0) [email protected] DK Denmark, Ballerup Tel: [email protected] ES Spain, Madrid Tel: [email protected] FI Finland, Vantaa Tel: +358 (0) [email protected] FR France, Contamine s/arve Tel: +33 (0) [email protected] GR Greece, Athens Tel: [email protected] HU Hungary, Budaoers Tel: [email protected] IE Ireland, Dublin Tel: +353 (0) [email protected] IT Italy, Corsico (MI) Tel: [email protected] KZ Kazakhstan, Almaty Tel: [email protected] NL The Netherlands, Oldenzaal Tel: +31 (0) [email protected] NO Norway, Asker Tel: [email protected] PL Poland, Warsaw Tel: +48 (0) [email protected] PT Portugal, Leca da Palmeira Tel: [email protected] RO Romania, Bucharest Tel: [email protected] RU Russia, Moscow Tel: [email protected] SE Sweden, Spånga Tel: +46 (0) [email protected] SK Slovakia, Banská Bystrica Tel: [email protected] SL Slovenia, Novo Mesto Tel: [email protected] TR Turkey, Istanbul Tel: [email protected] UA Ukraine, Kiev Tel [email protected] UK United Kingdom, Warwick Tel: +44 (0) [email protected] ZA South Africa, Kempton Park Tel: +27 (0) [email protected] North America CA Canada, Milton, Ontario Tel: US USA, Cleveland (industrial) Tel: US USA, Elk Grove Village (mobile) Tel: Asia Pacific AU Australia, Castle Hill Tel: +61 (0) CN China, Shanghai Tel: HK Hong Kong Tel: IN India, Mumbai Tel: JP Japan, Fujisawa Tel: +81 (0) KR South Korea, Seoul Tel: MY Malaysia, Shah Alam Tel: NZ New Zealand, Mt Wellington Tel: SG Singapore Tel: TH Thailand, Bangkok Tel: TW Taiwan, Taipei Tel: South America AR Argentina, Buenos Aires Tel: BR Brazil, Cachoeirinha RS Tel: CL Chile, Santiago Tel: MX Mexico, Apodaca Tel: Parker Hannifin Corporation. All rights reserved. Catalogue HY /GB, POD, 06/2013, ZZ, POD EMEA Product Information Centre Free phone: (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA) US Product Information Centre Toll-free number: Your local authorized Parker distributor
Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.
SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary
LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS
LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS 1. Define an accumulator and explain its function A hydraulic accumulator is a device that stores the potential energy of an incompressible fluid
The Eaton Advantage. machinery using accumulators.
Accumulators Table of Contents The EATON Advantage................................................................................. 3 Application Benefits...................................................................................
Accumulators. Bladder, Piston, Diaphragm
Accumulators Bladder, Piston, Diaphragm About HYDAC HYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributors worldwide and more than 30 wholly owned branches.
ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24
Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical
S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
Thermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
BLADDER SURGE CONTROL SYSTEM
PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures
AIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage
Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load
FLEXCON EXPANSION VESSELS. Flamco FLEXCON 2-80. Flexcon. Expansion vessels FLEXCON 110 1000 FLEXCON M. Flamco FLEXCON V-B.
FLEXCON EXPANSION VESSELS Flamco 1 Flexcon Expansion vessels FLEXCON 2-80 FLEXCON 110 1000 FLEXCON M Flamco FLEXCON V- 2007 edition / UK Flamco Flexcon the first name in expansion vessels Flamco has over
Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Ends : Min Temperature : Max Temperature : DN 32/40 to DN 1000 Between flanges GN10/16, ASA150 up to DN600-10 C + 110 C ( 130 C temporarily ) Max Pressure : 16 Bars up to DN300 Specifications :
SISTO-16TWA/HWA/DLU. Type Series Booklet
Diaphragm Valve SISTO-16TWA/HWA/DLU PN16 DN 15-200 Maintenance-free Flanged Ends Type Series Booklet Legal information/copyright Type Series Booklet SISTO-16TWA/HWA/DLU All rights reserved. The contents
RUBBER SLEEVE KNIFE GATE VALVE
RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve
CAT. 0113-GB MODELS. Series. Flat-face quick-release couplings. UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949
CAT. 0113-GB NEW MODELS Flat-face quick-release couplings UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949 FLAT-FACE QUICK-RELEASE COUPLINGS Features Benefits Applications Flat-face shut-off valves: easy to clean.
PN#02068195 / 1.15 / ACU1102-1326. Accumulators. Bladder, Piston, Diaphragm
Accumulators Bladder, Piston, Diaphragm About HYDAC HYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributors worldwide and more than 50 wholly owned branches.
DOUBLE GATE KNIFE GATE VALVE
DOUBLE GATE KNIFE GATE VALVE The model knife gate is a bi-directional valve widely used in the Pulp and Paper industry (recycling or secondary fibre processing) designed to handle high concentrated or
MFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
1. General 3. 2. Advantages of the piston accumulator 4. 3. Main applications 5-6. 4. Accumulator sizing 7-12. 5. Accumulator selection 13-14
Content Page 1. General 3 2. Advantages of the piston accumulator 4 3. Main applications 5-6 4. Accumulator sizing 7-12 5. Accumulator selection 13-14 6. Dimension and components 15-16 7. Accumulator station
*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
COUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE
B4 NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE AVAILABLE IN CARBON AND STAINLESS STEEL 23 THEORY
Self-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50
Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:
Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure
Check Valves & Actuated Valves
heck Valves & ctuated Valves & U Series Piston non-return valves rated 6,000 psi & 10,000 psi X Series Piston non-return valves rated 20,000 psi Pneumatic ctuators Pneumatically actuated valves Electric
QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
API Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
Chapter 5: Flow Valves
Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
08.08 Vic-Check Valves
The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc
Hydraulic Flow Control Valves
Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series
MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:
Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure
Bladder-type accumulator
Bladder-type accumulator RE 0170/02.12 Replaces: 12. Type HAB Component series 4X Nominal volume 1 to 0 liters Maimum operating pressure 30 bar Table of contents Contents Page Features 1 Ordering code
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS Hydraulic components POCLAIN HYDRAULICS Methodology : This document is intended for manufacturers of machines that incorporate Poclain Hydraulics products.
series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N
Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM ISO 9 No. CLEFFI / GB replaces / GB Function Pressure reducing valves are devices which, when installed
Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)
OPTIONS: USE: AVAILABLE MODELS: Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) DESCRIPTION The ADCA PRV47 pilot operated pressure reducing valves are designed for use on steam,
Type 3353 Angle Seat Valve
Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
HOSE, TUBE, AND PIPE CLAMPS
hose, tube & clamp B/W pages 24/6/08 9:28 AM Page 2 HOSE, TUBE, AND PIPE CLAMPS TABLE OF CONTENTS Introduction 3 Construction 3 Application 3 Mounting 3 Standard Duty Clamps (HRL) Arrangements 4 Dimensions
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features
High Pressure, Surge Anticipating Control Valve Eliminates surge in all pumping systems: Booster & deep well, single & variable speed Eliminates surge in all distribution networks: Municipal, high-rise
VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications
VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact
solarplus solar systems general features
SOLARPLUS solar systems solarplus Applications: expansion vessels for solar systems Zilmet, an internationally operating company with over 50 years of experience has grown to be the biggest European producer
POWER AND MOTION CONTROL FOR SUBSEA APPLICATIONS
POWER AND MOTION CONTROL FOR SUBSEA APPLICATIONS - HYDRAULICS - PNEUMATICS - ELECTROMECHANICS - SLIDING BEARINGS WWW.SERVI.NO LEADING SUPPLIER OF POWER AND MOTION CONTROL WITH A CENTURY OF EXPERIENCE -
Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)
Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where
BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features
Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive
Valve systems Base plates, according to standard ISO 5599-1. Brochure
ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure
HOPPER SHAPE KNIFE GATE VALVE
HOPPER SHAPE KNIFE GATE VALVE The model knife gate is a uni-directional wafer valve designed for industrial bulk handling service applications (powdered and granular products). The special design of the
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100
MODEL - FCA & FCA-S HD FIRE PROTECT TECHNICAL DATA MODELS FCA-65, FCA-80 & FCA-100 Carbon Steel Construction FCA-S 65, FCA-S 80 & FCA-S 100 Stainless Steel Construction INLET SIZE 65, 80, 100 NB WORKING
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...
VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate
Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage
Safety for Hydraulics Leak free check valve, pilot operated, series Cartridge type, two stage prevents a load from falling if a burst occurs in feed pipe hardened seat and poppet prevents creep of hydraulically
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
R310EN 2225 (2011.04) The Drive & Control Company
Ball Rail Systems Resist NRII R310EN 5 (011.04) he Drive & Control Company R310EN 5 (011.04) Ball Rail Systems Resist NR II Bosch Rexroth AG 3 Ball Rail Systems Resist NRII General Product Description
Workshop Compressors CLASSIC Series
www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your CLASSIC workshop compressor? Quality results can be achieved only by using
SAFETY BLOCK type BS 9.3 E 01-12
SAFETY BLOCK type BS 9.3 E 01-12 9.3.1 TECHNICAL DATA MAX OPERATING PRESSURE (PS): 420 bar PRESSURE TEST (PT): 1.43 x PS NOMINAL PASSAGE DIAMETER: 10mm, 20mm, 25mm, 32mm WORKING TEMPERATURE: -40 +150 FLUID
2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research
2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7
Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: [email protected] Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
BERMAD Waterworks. Surge Anticipating Control Valve. 700 Series. Model 735-M. Features and Benefits. Major Additional Features
Surge Anticipating Control Valve Eliminates surge in all pumping systems: Booster & deep well, single & variable speed Eliminates surge in all distribution networks: Municipal, high-rise buildings, sewage,
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Pressure Relief Valves SPV, SPVF
Pressure Relief Valves SPV, SPVF Construction of the Pressure Relief Valves SPV, SPVF Symbol Description The direct spring, sliding piston Pressure Relief Valve SPV/SPVF is intended for inline mounting
Backflush filter R8-30W
Backflush filter R8-30W With internal pressure segment cleaning, rated pressure to 40 bar (580 psi) Connection sizes: DN 200 to DN 500, welded design 1. Features Powerful, fully automatic filtration _
A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711
A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
VAG Non-Return Valves
VAG Non-Return Valves VAG SKR Slanted Seat Tilting Disk Check Valve Body Shaft Disk Bearing bush Seat Technical details Nominal pressure PN 10 / PN 16 Nominal diameter DN 200...1200 Fields of application:
Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.
M3 Plate heat exchanger Applications General heating and cooling duties. Heating by means of steam. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes
NDP-50 Specifications
NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped
NITROGEN CHARGING KIT type PCM 11.2 E 04-11
NITROGEN CHARGING KIT type PCM 11.2 E 04-11 11.2.1 TECHNICAL DATA MAX OPERATING PRESSURE (PS): 400 BAR PRESSURE TEST (PT): 1.43 PS SCALE OF PRESSURE GAUGE: 4-10 - 16-25 - 60-100 - 250 (std.) - 400 bar
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps
An SPX Process Equipment Operation Universal II Industrial Series Rotary Positive Displacement ECP Pumps New levels of performance. Reduced operational and maintenance costs. For more than half a century,
2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS
2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features
Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,
Fisher 2625, 2625SST, and 2625NS Volume Boosters
Instruction Manual 2625, 2625SST, and 2625NS Volume Booster Fisher 2625, 2625SST, and 2625NS Volume Boosters Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Educational
British Standard Underground Hydrant Range
British Standard Underground Hydrant Range 2 THE NEW AVK BRITISH STANDARD HYDRANT RANGE AVK are the renowned market leading innovators, manufacturers and suppliers of BS 750 fire hydrants into the UK,
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
DOUBLE BLOCK AND BLEED VALVES
DOUBLE BLOCK AND BLEED VALVES ENGINEERING - QUALITY AND TESTING Energy Valves is specialized in designing and manufacturing DBB valves (ball - plug - gate). Technical solutions and engineering are in accordance
VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
