Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

Size: px
Start display at page:

Download "Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam."

Transcription

1 M3 Plate heat exchanger Applications General heating and cooling duties. Heating by means of steam. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a fixed frame plate and a movable pressure plate and compressed by tightening bolts. The plates are fitted with a gasket which seals the interplate channel and directs the fluids into alternate channels. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure. The plate and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar, both of which are fixed to a support column. Connections are located in the frame plate or, if either or both fluids make more than a single pass within the unit, in the frame and pressure plates. Typical capacities Liquid flow rate Up to 60 GPM, depending on media, permitted pressure drop and temperature program. Water heating by steam 50 to 250 kw, 14 tons to 90 tons M3-VG Plate types M3 and M3-X, where M3 provides parallel and M3-X diagonal flow (see figures on the next page). M3D, double wall plates. Frame types VG VGL (non-asme)

2 Working principle Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. The heat is transferred through the plate between the channels, and complete counter-current flow is created for highest possible efficiency. The corrugation of the plates provides the passage between the plates, supports each plate against the adjacent one and enhances the turbulence, resulting in efficient heat transfer. Flow principle of an M3 plate heat exchanger Standard materials Frame plate Mild steel, painted Nozzles Stainless steel AISI 316 or Titanium Plates Stainless steel AISI 316 or Titanium Flow principle of an M3-X plate heat exchanger Gaskets M3 Nitrile, EPDM M3X Nitrile, EPDM, Viton M3D Nitrile, EPDM Dimensions 7" 2-3 8" Connections 1-1 4" NPT Technical data Mechanical design pressure (g)/temperature VG 230 Psig/320ºF FGL 230 Psig/320 F (non-asme) 19" 14" Maximum heat transfer surface 40 sq. ft 2-1 2" 7-1 2" " 1-1 4" Particulars required for quotation Flow rates or heat load Temperature program Physical properties of liquids in question (if not water) Desired working pressure Maximum permitted pressure drop Available steam pressure Measurements (mm) The number of bolts may vary depending on pressure rating. ENSR00001USEN 0206 All rights reserved for changes in specifications THERMAL How to contact TRANSFER Alfa Laval SYSTEMS, INC. SALES@THERMALTRANSFERSYSTEMS.COM Contact details for all countries PH: are continually updated FAX: on our website. Please visit to access the information directly.

3 M6 Plate heat exchanger Applications General heating and cooling duties. Heating by means of steam. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a fixed frame plate and a movable pressure plate and compressed by tightening bolts. The plates are fitted with a gasket which seals the interplate channel and directs the fluids into alternate channels. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure. The plate and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar, both of which are fixed to a support column. Connections are located in the frame plate or, if either or both fluids make more than a single pass within the unit, in the frame and pressure plates. Typical capacities Liquid flow rate Up to 250 gpm, depending on media, permitted pressure drop and temperature program. M6-FG Water heating by steam 80 tons to 225 tons Plate types M6 and M6M Frame types FG, FD (ASME design) FGL (non-asme)

4 Working principle Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. The heat is transferred through the plate between the channels, and complete counter-current flow is created for highest possible efficiency. The corrugation of the plates provides the passage between the plates, supports each plate against the adjacent one and enhances the turbulence, resulting in efficient heat transfer. Standard materials Frame plate Mild steel, painted Nozzles Flange: Stainless steel, Titanium Lined: Stainless steel, Titanium Pipe: Stainless steel Plates Stainless steel AISI 316 Titanium (M6M only) Gaskets M6 Nitrile, EPDM, HeatSeal F M6M Nitrile, EPDM, HeatSeal F, Viton G Connections Pipe connections: 2" NPT With flanges: FG 2" SOLJ ANSI 150 FD 2" SOLJ ANSI 150/ANSI 300 Dimensions 25.2" 5.51" Flow principle of a plate heat exchanger 20" 55" Technical data Mechanical design pressure (g)/temperature FGL 150 psig/320ºf (non-asme) FG 150 psig/356ºf FD 360 psig/356ºf Maximum heat transfer surface 410 sq. ft. Measurements (mm) Type H W h M6-FGL 36.22" 12.60" 5.51" M6-FG 36.22" 12.60" 5.51" M6-FD 37" 13" 5.91" The number of tightening bolts may vary depending on pressure rating. Particulars required for quotation Flow rates or heat load Temperature program Physical properties of liquids in question (if not water) Desired working pressure Maximum permitted pressure drop Available steam pressure ENSR00002USEN 0206 All rights reserved for changes in specifications THERMAL TRANSFER SYSTEMS, INC. SALES@THERMALTRANSFERSYSTEMS.COM How to contact Alfa Laval PH: Contact details for all FAX: countries are continually updated on our website. Please visit to access the information directly.

5 TS6 Plate Heat Exchanger Applications General heating and cooling duties. Heating by means of steam. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a fixed frame plate and a movable pressure plate and compressed by tightening bolts. The plates are fitted with a gasket which seals the interplate channel and directs the fluids into alternate channels. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure. The plate and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar, both of which are fixed to a support column. Connections are located in the frame plate or, if either or both fluids make more than a single pass within the unit, in the frame and pressure plates. Typical capacities Liquid flow rate Up to 20 kg/s (158,400 lb/hr), depending on media, permitted pressure drop and temperature program. Water heating by steam 200 1,800 kw (682,400 6,141,600 BTU/hr) Plate types TS6M Frame types FG and FD TS6-MFG

6 Working principle Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. The heat is transferred through the plate between the channels, and complete counter-current flow is created for highest possible efficiency. The corrugation of the plates provides the passage between the plates, supports each plate against the adjacent one and enhances the turbulence, resulting in efficient heat transfer. Standard Materials Frame plate Mild steel, Epoxy painted Nozzles Carbon steel Lined: Stainless steel, Titanium Flow principle of a plate heat exchanger Plates Stainless steel AISI 316 or Titanium Dimensions Gaskets Nitrile, EPDM or HeatSeal F Connections FG ASME Size 3" ANSI 150 FD ASME Size 2 1/2" ANSI 300 Technical data Mechanical design pressure (g)/temperature FG ASME 150 psig /350 F FD ASME 300 psig /350 F Maximum heat transfer surface 13 m 2 (140 sq. ft.) Particulars required for quotation Flow rates or heat load Temperature program Physical properties of liquids in question (if not water) Desired working pressure Maximum permitted pressure drop Available steam pressure Measurements (in/mm) Type H W h TS6-FG 27.72/ / /188 TS6-FD 27.72/ / /188 The number of tightening bolts may vary depending on pressure rating. PD E All rights reserved for changes in specifications THERMAL TRANSFER SYSTEMS, INC. How to contact Alfa Laval SALES@THERMALTRANSFERSYSTEMS.COM Contact details for all countries PH: FAX: are continually updated on our website. Please visit to access the information directly.

7 M10 Plate heat exchanger Applications General heating and cooling duties. Heating by means of steam. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a fixed frame plate and a movable pressure plate and compressed by tightening bolts. The plates are fitted with a gasket which seals the interplate channel and directs the fluids into alternate channels. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure. The plate and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar, both of which are fixed to a support column. Connections are located in the frame plate or, if either or both fluids make more than a single pass within the unit, in the frame and pressure plates. Typical capacities Liquid flow rate Up to 980 gpm, depending on media, permitted pressure drop and temperature program. M10-BFG Water heating by steam 0.7 to 3.0 MW 200 tons 850 tons Plate types M10B, M10M and M10BD Frame types FM, FG and FD (ASME design) FML (non-asme)

8 Working principle Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. The heat is transferred through the plate between the channels, and complete counter-current flow is created for highest possible efficiency. The corrugation of the plates provides the passage between the plates, supports each plate against the adjacent one and enhances the turbulence, resulting in efficient heat transfer. Standard materials Frame plate Mild steel, painted Flow principle of a plate heat exchanger Nozzles Carbon steel Lined: Stainless steel, Titanium Dimensions Plates Stainless steel AISI 304, AISI 316 Titanium, Alloy 20/18/6 8.86" or 9.125" Gaskets M10B Nitrile, EPDM, Viton G M10M Nitrile, EPDM, HeatSeal F EPDMF-FDA, Viton G 26.3" Connections FML Size 4" ANSI 150 FM Size 4" ANSI 150 FG Size 4" ANSI 150 FD Size 4" ANSI 150 FD Size 4" ANSI 300 Measurements (mm) 34" 92" Technical data Mechanical design pressure (g)/temperature FML 150 psig/320 F (non-asme) FM 100 psig/320 F FG 150 psig/356 F FD 360 psig/356 F Maximum heat transfer surface M10B 1126 sq. ft. M10M 660 sq. ft. Type H W h M10-FML 38.62" 18.11" " M10-FM 38.62" 18.11" " M10-FG 38.62" 18.5" " M10-FD 42.70" 18.5" " The number of tightening bolts may vary depending on pressure rating. Particulars required for quotation Flow rates or heat load Temperature program Physical properties of liquids in question ((if not water) Desired working pressure Maximum permitted pressure drop Available steam pressure ENSR00003USEN 0206 All rights reserved for changes in specifications THERMAL How to contact TRANSFER Alfa Laval SYSTEMS, INC. SALES@THERMALTRANSFERSYSTEMS.COM Contact details for all countries PH: FAX: are continually updated on our website. Please visit to access the information directly.

9 M15 Plate heat exchanger Applications General heating and cooling duties. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a fixed frame plate and a movable pressure plate and compressed by tightening bolts. The plates are fitted with a gasket which seals the interplate channel and directs the fluids into alternate channels. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure. The plate and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar, both of which are fixed to a support column. Connections are located in the frame plate or, if either or both fluids make more than a single pass within the unit, in the frame and pressure plates. Typical capacities Liquid flow rate Up to 1,850 gpm, depending on media, permitted pressure drop and temperature program. Plate types M15B, M15E and M15M M15-FG Frame types FG, FD and FS (ASME design) FML (Non-ASME design)

10 Working principle Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. The heat is transferred through the plate between the channels, and complete counter-current flow is created for highest possible efficiency. The corrugation of the plates provides the passage between the plates, supports each plate against the adjacent one and enhances the turbulence, resulting in efficient heat transfer. Standard materials Frame plate Mild steel, Epoxy painted Nozzles Carbon steel Lined: Stainless steel, Titanium Flow principle of a plate heat exchanger Plates Stainless steel: AISI 304, AISI 316 Titanium Alloy C-276 Alloy 254 SMO Gaskets (Clip-on/Tape-on,Glued) Nitrile Nitrile hydrogenated EPDM Viton G AL-EPDM Connections FML Size 6" ANSI 150 FG Size 6" ANSI 150 FD Size 6" ANSI 300 FS Size 6" ANSI 300 Dimensions 2.2" 50.9" 11.7" Measurements (mm) 44" 128" Technical data Max.working pressure FML 150 psig/320 o F (Non-ASME) FG 150 psig/320 o F FD 300 psig/320 o F FS 460 psig/320 o F Maximum heat transfer surface 4,200 sq.ft Type H W h M15-FML 71.5" 24" 10.83" M15-FG 76.4" 25.6" 10.83" M15-FD 80.1" 25.6" 14.57" M15-FS 80.1" 25.6" 14.57" The number of tightening bolts may vary depending on pressure rating. Particulars required for quotation Flow rates or heat load Temperature program Desired working pressure Maximum permitted pressure drop Available steam pressure ENSR00004USEN 0206 All rights reserved for changes in specifications THERMAL TRANSFER SYSTEMS, INC. SALES@THERMALTRANSFERSYSTEMS.COM How to contact Alfa Laval PH: Contact details for FAX: all countries are continually updated on our website. Please visit to access the information directly.

11 TS20M Plate heat exchanger Applications General heating and cooling duties. Heating by means of steam. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a fixed frame plate and a movable pressure plate and compressed by tightening bolts. The plates are fitted with a gasket which seals the interplate channel and directs the fluids into alternate channels. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure. The plate and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar, both of which are fixed to a support column. Connections are located in the frame plate or, if either or both fluids make more than a single pass within the unit, in the frame and pressure plates. Typical capacities Liquid flow rate Up to 190 kg/s, depending on media, permitted pressure drop and temperature program. Water heating by steam MW at a steam condensation temperature of 150 C MW at a steam condensation temperature of 120 C Plate types TS20M plates Frame types FG and FS

12 Working principle Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. The heat is transferred through the plate between the channels, and complete counter-current flow is created for highest possible efficiency. The corrugation of the plates provides the passage between the plates, supports each plate against the adjacent one and enhances the turbulence, resulting in efficient heat transfer. Standard materials Frame plate Mild steel, epoxy painted Nozzles Carbon steel Metal lined: Stainless steel, Titanium Flow principle of a plate heat exchanger Plates Stainless steel AISI 316 or Titanium Gaskets Nitrile, EPDM or HeatSeal F Dimensions W 363 Connections FG ASME Size 8" ANSI 150 FS ASME Size 8" ANSI 150/ANSI 300 Technical data Mechanical design pressure (g)/temperature FG ASME 150 psig /350 F FS ASME 400 psig /320 F *Frame FG also approved for 1.2 MPa /200 C to allow use in steam systems without safety valves. H Maximum heat transfer surface 85 m 2 (910 sq. ft) Particulars required for quotation Flow rates or heat load Temperature program Physical properties of liquids in question (if not water) Desired working pressure Maximum permitted pressure drop Available steam pressure Measurements (mm) Type H W H TS20-MFG TS20-MFS PD 68200E1/0110 All rights reserved for changes in specifications THERMAL TRANSFER SYSTEMS, INC. SALES@THERMALTRANSFERSYSTEMS.COM How to contact Alfa Laval PH: Contact details for all FAX: countries are continually updated on our website. Please visit to access the information directly.

13 MX25 Plate heat exchanger Applications Plate heat exchanger for general heating and cooling duties. Standard design The plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a fix frame plate and a movable pressure plate and compressed by tightening bolts. The plates are fitted with a gasket, which seals the interplate channel and directs the fluids into alternate channels. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure. The plate and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar, both of which are fixed to a support column. Connections are located in the frame plate or, if either or both fluids make more than a single pass within the unit, in the frame and pressure plates. Typical capacities Liquid flow rate. Up to 350 kg/s (5600 gpm), depending on media, permitted pressure drop and temperature program. Plate types MX25B and MX25M plates Frame types FMS, FGS, FG, FD and FS MX25-BFG Working principle Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. The heat is transferred through the plate between the channels, and complete counter-current flow is created for highest possible efficiency. The corrugation of the plates provides the passage between the plates, supports each plate against the adjacent one and enhances the turbulence, resulting in efficient heat transfer.

14 Standard materials Frame plate Mild steel, Epoxy painted Nozzles Carbon steel Metal lined: Stainless steel, Titanium Rubber lined: Nitrile, EPDM Plates Stainless steel Alloy 316, Alloy C276, Alloy 254 SMO or Titanium Gaskets Nitrile or EPDM Flow principle of a plate heat exchanger Technical data Pressure vessel codes PED, ASME, pvcals Mechanical design pressure (g) / temperature FMS PED, pvcals 1.0 MPa / 180 C FGS PED, pvcals 1.6 MPa / 180 C FGS ASME 150 psig / 350 F FG PED, pvcals 1.6 MPa / 180 C FG ASME 150 psig / 350 F FD PED, pvcals 2.5 MPa / 180 C FD ASME 300 psig / 350 F FS ASME 400 psig / 350 F Connections FMS PED Size 200/250 mm DIN 2501 PN10, ASME Cl. 150 FMS pvcals Size 200/250 mm DIN 2501 PN10, ASME Cl. 150, JIS 10K FGS PED Size 200 mm DIN 2501 PN16, ASME Cl. 150 FGS pvcals Size 200/250 mm DIN 2501 PN16, ASME Cl. 150, JIS 16K FGS ASME Size 8 ASME Cl. 150 FG PED Size 200/250 mm DIN 2501 PN16, ASME CI. 150 FG pvcals Size 200/250 mm DIN 2501 PN16, ASME Cl. 150, JIS 16 K FG ASME Size 8 /10 ASME Cl.150 FD PED Size 200/250 mm DIN 2501 PN25, ASME Cl. 300 FD ASME Size 8 /10 ASME Cl. 300 FS ASME Size 8 /10 ASME Cl. 400 Maximum heat transfer surface 940 m 2 ( sq. ft) Dimensions H h 1939 (76.3 ) W 439 (17.3 ) Measurements mm (inch) ( ) Type H W h MX25-FMS 2595 (102 ) 920 (36.2 ) 325 (12.8 ) MX25-FGS 2595 (102 ) 920 (36.2 ) 325 (12.8 ) MX25-FG max 3100 (122 ) 920 (36.2 ) 435 (17.1 ) MX25-FD max 3100 (122 ) 940 (37 ) 435 (17.1 ) MX25-FS max 3100 (122 ) 940 (37 ) 435 (17.1 ) The number of tightening bolts may vary depending on the pressure rating Particulars required for quotation Flow rates or heat load Temperature program Physical properties of liquids in question (if not water) Desired working pressure Maximum permitted pressure drop Available steam pressure PCT00038EN 0904 Alfa Laval reserves the right to change specifications without prior notification. THERMAL TRANSFER SYSTEMS, INC. SALES@THERMALTRANSFERSYSTEMS.COM PH: FAX: How to contact Alfa Laval Contact details for all countries are continually updated on our website. Please visit to access the information direct.

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

Sanitary Heat Exchangers. The Complete Line

Sanitary Heat Exchangers. The Complete Line Sanitary Heat Exchangers The Complete Line Gasketed Plate Heat Exchangers Everything you need, everywhere you need it Alfa Laval is a world-leading supplier of heat exchangers for a wide range of sanitary

More information

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project: PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name

More information

Plate Heat Exchangers. Series FP, FPDW

Plate Heat Exchangers. Series FP, FPDW Plate Heat Exchangers Series FP, FPDW With partnership into the future FUNKE is a leader in the development and production of quality heat exchangers with a heat transfer area of up to 2 400 m². The range

More information

Design and Cost Optimization of Plate Heat Exchanger

Design and Cost Optimization of Plate Heat Exchanger Research Inventy: International Journal Of Engineering And Science Vol.4, Issue 10 (October2014), PP 43-48 Issn (e): 2278-4721, Issn (p):2319-6483, www.researchinventy.com Design and Cost Optimization

More information

DOUBLE GATE KNIFE GATE VALVE

DOUBLE GATE KNIFE GATE VALVE DOUBLE GATE KNIFE GATE VALVE The model knife gate is a bi-directional valve widely used in the Pulp and Paper industry (recycling or secondary fibre processing) designed to handle high concentrated or

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

VAD. Variable Area Desuperheaters

VAD. Variable Area Desuperheaters Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated

More information

QLM and QLD Series Three-port Control Valves

QLM and QLD Series Three-port Control Valves Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

HOPPER SHAPE KNIFE GATE VALVE

HOPPER SHAPE KNIFE GATE VALVE HOPPER SHAPE KNIFE GATE VALVE The model knife gate is a uni-directional wafer valve designed for industrial bulk handling service applications (powdered and granular products). The special design of the

More information

Alfa Laval plate technology. It s all about optimizing everything

Alfa Laval plate technology. It s all about optimizing everything Alfa Laval plate technology It s all about optimizing everything Alfa Laval s business activities have one sole focus providing you as the customer with technologies and solutions that help you optimize

More information

GRUNDFOS COMMERCIAL BUILDINGS

GRUNDFOS COMMERCIAL BUILDINGS GRUNDFOS COMMERCIAL BUILDINGS Grundfos provides a full range of gasketed and brazed plate heat exchangers designed for heating, ventilation, air-conditioning and cooling applications. BRAZED PLATE HEAT

More information

Sondex Welded heat exchangers:

Sondex Welded heat exchangers: Sondex A/S is a Danish company specialized in the development, design and production of plate heat exchangers and freshwater distillers. Since its foundation in 1984 SONDEX has grown into a wide global

More information

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) OPTIONS: USE: AVAILABLE MODELS: Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) DESCRIPTION The ADCA PRV47 pilot operated pressure reducing valves are designed for use on steam,

More information

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24 Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

The Unique Accelabar Flow Meter

The Unique Accelabar Flow Meter The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.

More information

3M Housings DS Series

3M Housings DS Series Lenntech info@lenntech.com Tel. +1-15-610-900 www.lenntech.com Fax. +1-15-616-89 M Housings For Filters Filter Housings, constructed of durable stainless steel, meet general-purpose industrial, chemical,

More information

Automatic Self-Cleaning Strainers

Automatic Self-Cleaning Strainers Applications Water and Liquid service Power Industry Cooling water Pulp & Paper Removing fibers Process Equipment Protect equipment Metal & Mining Quenching, blast furnace cooling Automatic Self-Cleaning

More information

VAD Variable Area Desuperheaters

VAD Variable Area Desuperheaters Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Questionnaire Pure Media Systems

Questionnaire Pure Media Systems 1. PROJECT INFORMATION: Project Name: Client: Contact Person: Telephone / Fax N : Email: 2. BASIC INFORMATION Type of Pure Media System PW / HPW - Generation PW / HPW - Storage & Distribution System Cold

More information

Pressure and Temperature Controls

Pressure and Temperature Controls Pressure and Controls Pressure Reducing Armstrong pressure reducing valves (PRVs) and temperature regulators help you manage steam, air and liquid systems safely and efficiently. And assure uninterrupted

More information

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston. SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary

More information

Stainless Steel Valves For the Sanitary Industries

Stainless Steel Valves For the Sanitary Industries www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½ to 12 Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Corrugated Tubular Heat Exchangers

Corrugated Tubular Heat Exchangers Corrugated Tubular Heat Exchangers HEAT EXCHANGERS for the 21st CENTURY Corrugated Tubular Heat Exchangers (CTHE) Corrugated Tube Heat Exchangers are shell and tube heat exchangers which use corrugated

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

RMF Engineering 23 05 23

RMF Engineering 23 05 23 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

API Flanged Safety Relief Valves Series 526 CATALOG

API Flanged Safety Relief Valves Series 526 CATALOG API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409 Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

solarplus solar systems general features

solarplus solar systems general features SOLARPLUS solar systems solarplus Applications: expansion vessels for solar systems Zilmet, an internationally operating company with over 50 years of experience has grown to be the biggest European producer

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Trash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001

Trash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001 Trash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001 Specifically designed pumps for heavy duty applications Handles solids with eas and simple to open and clean Standard roll

More information

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief

More information

Wafer, Semi-Lug, Lug and Double Flanged Type

Wafer, Semi-Lug, Lug and Double Flanged Type Wafer, Semi-Lug, Lug and Double Flanged Type Page 1 www.globalvalvecenter.com 2011 Description The centric replaceable liner butterfly valve is capable of bi-directional flow and bubble tight shut-off

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

WD600 STEAM TRAPS. Thermodynamic Steam Trap

WD600 STEAM TRAPS. Thermodynamic Steam Trap WD600 Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company WD600, WD600L Sizes 3/8, 1/2, 3/4, 1 NPT Material Stainless

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE. www.sharpevalves.

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE. www.sharpevalves. Valves, Automation & Controls series 8 /99 & FS8 /FS99 HIGH PERFORMANCE -PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE www.sharpevalves.com Design & Features SHARPE VALVES - SERIES 8/99 Fire

More information

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products. Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils

More information

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

Accumulators, Accessories and Spares

Accumulators, Accessories and Spares Accumulators, Accessories and Spares HY10-4004/UK - Effective June 1st, 2013 Index Table of Contents Table of Contents 2 Introduction 3 How to Size? 4 General Information Accumulators 5-8 Bladder Accumulators

More information

Solar Collector Series. Product List

Solar Collector Series. Product List Solar Collector Series List FULL COLLECTORS (MANIFOLD, TUBES & ROOF FRAME) : CSR00051 Apricus Collector : AP10 10-Way Manifold, 10 Tubes and Standard Roof Frame CSR00052 Apricus Collector : AP20 20-Way

More information

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE: WWW.WERMAC.ORG/

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE: WWW.WERMAC.ORG/ TEMA DESIGNATIONS OF HEAT EXCHANGERS Because of the number of variations in mechanical designs for front and rear heads and shells, and for commercial reasons, TEMA has designated a system of notations

More information

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

Rosemount 1199 Submersible Seal

Rosemount 1199 Submersible Seal Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and

More information

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Ed.15.01 Design Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Standard 4026/60H Pressure rate PN 40

More information

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

DOUBLE SEAT BRONZE BODY HIGH CAPACITY PS593DB HEAVY DUTY BRONZE GLOBE CONTROL VALVES DB DOUBLE SEAT BRONZE BODY HIGH CAPACITY 1, 1-1/4, 1-1/2, and 2 Union Ends ANSI Class 250 Body Rating ANSI Class II Close off Bronze or Stainless Steel Trim

More information

08.08 Vic-Check Valves

08.08 Vic-Check Valves The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc

More information

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com. Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

RING JOINT SYSTEMS 207

RING JOINT SYSTEMS 207 RING JOINT SYSTEMS 07 08 Table of Contents Model R-88 Pages 10-11 Model R-88 Large Diameter Page 1 Model RH-1000 1000 PSI Coupling Page 13 Model RX-3000 3000 PSI Coupling Page 1 Model RX-3770 3770 PSI

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain

More information

PBX Series Quick Fit Connector Bimetallic Steam Traps

PBX Series Quick Fit Connector Bimetallic Steam Traps 6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

P.E.D. 97/23/EC/0424 Butterfly Valves Series SL, SLK Group 1-2 Class I, II, III ATEX CE Ex II 2 GD

P.E.D. 97/23/EC/0424 Butterfly Valves Series SL, SLK Group 1-2 Class I, II, III ATEX CE Ex II 2 GD 1. GENERAL 1.1 CONSTRUCTION Small size and light construction gives advantage in installation, stocking and transporting. Sizes from DN 300 to 600 are equipped with ears, which helps the centering of the

More information

Self-contained valve functions as integral check valve, flow sensing element and bypass control valve.

Self-contained valve functions as integral check valve, flow sensing element and bypass control valve. Self-contained valve functions as integral check valve, flow sensing element and bypass control valve. Features Eliminates high cost of installation and maintenance of complex conventional flow control

More information

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size CRANE Σελίδα από 2 DM93 Variable Orifice Double Regulating Valve PN6 Cast Iron Balancing Valve (VODRV), Flanged to BSEN 92-2 The DM93 variable orifice double regulating valves will give satisfactory performance

More information

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description Worldwide Contacts www.tyco-fire.com Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description The TYCO Model WS Specific Application Window

More information

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics THORTO Leading Pure Water nalytics Economical Paddlewheel Hi-Purity PF Ultrasonic Vortex Insertion-type Vortex Convenient, Reliable and Economical Flow Measurement Paddlewheel Reliable and Economical Inline

More information

CSF16 and CSF16T Stainless Steel Steam Filters

CSF16 and CSF16T Stainless Steel Steam Filters Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

PLATE HEAT EXCHANGER. Maintenance Manual. Customer Name: Serial Number: Purchase order number: Project Name:

PLATE HEAT EXCHANGER. Maintenance Manual. Customer Name: Serial Number: Purchase order number: Project Name: PLATE HEAT EXCHANGER Maintenance Manual Customer Name: Serial Number: Purchase order number: Project Name: Table of Contents ----------------------------------------------------------------- Page: 3 Name

More information

BLADDER SURGE CONTROL SYSTEM

BLADDER SURGE CONTROL SYSTEM PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures

More information

Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its

More information

Model DE-3 Air Release Head

Model DE-3 Air Release Head SPECIFICATIONS MEASUREMENT SOLUTIONS Model Air Release Head Bulletin SS03037 Issue/Rev. 0.2 (10/15) We put you first. And keep you ahead. SMITH METER AIR ELIMINATOR The Smith Meter Model Air Release Heads

More information

FLEXIBLE SOLUTIONS FOR FLUIDS AND GASES

FLEXIBLE SOLUTIONS FOR FLUIDS AND GASES FLEXIBLE SOLUTIONS FOR FLUIDS AND GASES www.amnitec.nl AmniTec B.V., Rotterdam, is part of a group of companies called United Flexible with an annual turnover of $ 70 Million and 5 operating facilities

More information

Pressure & Flame Protection

Pressure & Flame Protection Pressure & Flame Protection Safety Relief Valves Safety Relief Valves WB SERIES SPRING LOADED SAFETY RELIEF VALVES The WB is designed safely relieve excess pressure in pumps, pipework, tanks, calorifiers,

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Standard offering (pumps)

Standard offering (pumps) MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk

More information

TY-FLO Needle Valves

TY-FLO Needle Valves Design/Features Hard (Vee) or Delrin Soft Seat/Tip Orifice sizes from.17 to.438 in. Flow Coefficients (C V ) from.37 to.7 Straight or angle flow patterns Optional panel mount Handle options available Non-wetted

More information

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves 2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve

Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications

More information

NDP-50 Specifications

NDP-50 Specifications NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

Flygt Ball Check Valves

Flygt Ball Check Valves 4/13 Supersedes: 6/96 The basic purpose of a check valve is to permit flow in one direction, prevent flow in the opposite direction and perform this function automatically and with minimum maintenance.

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS-80025201-ARS PAGE 1 OF 5

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS-80025201-ARS PAGE 1 OF 5 BULLETIN # PVS-80050-ARS PAGE OF 5 GENERAL Air Removal Systems generally consist of dual 00% (twin-element) ejecrs, single 00% surface-type inter- & aftercondensers, suction & discharge isolation valves

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information