MANUFACTURING, ENGINEERING, INDUSTRIAL REPAIR AND OVERHAUL OF ELECTRIC TRACTION EQUIPMENT

Size: px
Start display at page:

Download "MANUFACTURING, ENGINEERING, INDUSTRIAL REPAIR AND OVERHAUL OF ELECTRIC TRACTION EQUIPMENT"

Transcription

1 PROIZVODNJA, INŽENJERING, SERVISIRANJE I REMONT OPREME ZA ELEKTRIČNU VUČU MANUFACTURING, ENGINEERING, INDUSTRIAL REPAIR AND OVERHAUL OF ELECTRIC TRACTION EQUIPMENT 1

2 KONTAKTOR KN-5214 Elektropneumatski jednopolni kontaktor Nazivni napon Un =1000V jss Nazivna struja In = 1600A 6 max. (In=10A, Un=110V) KONTAKTOR KVJ-3 Elektropneumatski jednopolni kontaktor Nazivni napon Un = 2200V jss Nazivna struja In = 400 A 4 max. (In=10A, Un=110V) KONTAKTORI KJ-1 KJ-2 KJ-3 Elektromagnetni jednopolni kontaktori Nazivni napon Un = 600V jss Nazivna struja In = A 5 max. (In=10A, Un=24V) KONTAKTORI KG-16 - KG-50 Elektromagnetni jednopolni kontaktori Nazivni napon Un = 3000V jss Nazivna struja In = 5-16A 2NO + 2NZ (In=5A, Un=250V) CONTACTOR KN-5214 Electro-pneumatic single-pole contactor Rated voltage Un=1000V DC Rated current In = 1600A 6 max. (In=10A, Un=110V) CONTACTOR KVJ-3 Electro-pneumatic single-pole contactor Rated voltage Un=2200V DC Rated current In = 400 A 4 max. (In=10A, Un=110V) CONTACTORS KJ-1 KJ-2 KJ-3 Electromagnetic single-pole contactors Rated voltage Un =600V DC Rated current In = A 5 max. (In=10A, Un=24V) CONTACTORS KG-16 - KG-50 Electromagnetic single-pole contactors Rated voltage Un=3000V DC Rated current In = 5 16A 2NO + 2NC (In=5A, Un=250V) 2

3 KONTAKTORI K-1 Elektromagnetni jednopolni kontaktori Nazivni napon Un = 110V jss Nazivna struja In = A 2NO + 2NZ (In=1A, Un=110V) KONTAKTORI KJ-031 Elektromagnetni jednopolni kontaktori Nazivni napon Un = 110V jss Nazivna struja za L/R=2ms In=100A 2NO + 2NZ (In=1A, Un=110V) LINIJSKI PREKIDAČ SL 11 A Kontaktor kombinovan sa relejem preopterećenja Nazivni napon Un = 750V jss Nazivna struja In = 50A Podešavanje isključenja do 750A 9 max. (In=10A, Un=110V) CONTACTORS K-1 Electromagnetic single-pole contactors Rated voltage Un = 110V DC Rated current In = A 2NO + 2NC (In=1A, Un=110V) CONTACTORS KJ-031 Electromagnetic single-pole contactors Rated voltage Un = 110V DC Rated current for L/R=2ms In=100A 2NO + 2NC (In=1A, Un=110V) LINE BREAKER SL 11 A Contactor combined with overload relay Rated voltage Un = 750V DC Rated current In = 50A Trip setting to 750A 9 max. (In=10A, Un=110V) KONTROLER DKJU-III/C Direktni kontroler sa 10 kontaktnih elemenata Nazivni napon Un = 600V jss Nazivna struja In = 300A 4 max. (In=15A, Un=110V) CONTROLGEAR DKJU-III/C Direct conctroller with 10 contact elements Rated voltage Un = 600V DC Rated current In = 300 A 4 max. (In=15A, Un=110V) 3

4 KONTROLER IKJ-V/A Indirektni kontroler sa 20 kontaktnih elemenata Nazivni napon Un = 110V jss Nazivna struja In = 10A CONTROLGEAR IKJ-V/A Indirect controller with 20 contact elements Rated voltage Un = 110V DC Rated current In = 10A KONTROLER IKJ-X/A Indirektni kontroler sa 36 kontaktnih elemenata i potenciometrom Nazivni napon Un =110V jss Nazivna struja In =10A CONTROLGEAR IKJ-X/A Indirect controller with 36 contact elements and potentiometer Rated voltage Un =110V DC Rated current In = 10A KONTROLER ZA PROMENU SMERA DKJK-V/A Nazivni napon Un =1000V jss Nazivna struja In = 1200A 4 max. (In=10A, Un=110V) REVERSING SWITCH DKJK-V/A Rated voltage Un=1000V DC Rated current In = 1200A 4 max. (In=10A, Un=110V) REGULATOR NAPONA RTN stepen regulacije na primaru transformatora Nazivni napon: Un = 25 kv, 50 Hz TAP CHANGER RTN-25 Discontinual regulation in 41 degrees on the high voltage transformer side Rated voltage: Un = 25 kv, 50 Hz 4

5 OTPORNIK ZA POLAZAK OA stepena regulacije Nazivni napon Un =600V jss STARTING RESISTOR OA steps Rated voltage Un =600V DC PANTOGRAF POS-254/III Jednolakatni oduzimač struje sa 2 klizača Pneumatsko upravljanje Nazivni napon Un = 25kV Nazivna struja In = 600A PANTOGRAPH POS-254/III Single-arm pantograph with 2 sliders Pneumatically operated Rated voltage Un = 25kV. Rated current In = 600A RASTAVLJAČ RSP 25 Pantografski rastavljač na krovu električne lokomotive Nazivni napon Un = 25kV Nazivna struja In = 500A PANTOGRAPH DISCONNECTER RSP 25 Pantograph disconnecter installed on the roof of electric locomotive Rated voltage Un = 25kV Rated current In = 500A RASTAVLJAČ PR-2/A Rastavljač za uzemljenje na krovu električne lokomotive Nazivni napon Un = 25kV Nazivna struja In = 500A ROOF DISCONNECTER PR-2/A Roof earthing disconnecter for electric locomotive Rated voltage Un = 25kV Rated current In = 500A 5

6 RASTAVLJAČ PR-1/F Rastavljač kontaktne mreže Nazivni napon Un = 1500V Nazivna struja In = 2000A LINE DISCONNECTER PR-1/F Contact line disconnecter Rated voltage Un = 1500V Rated current In = 2000A UZEMLJIVAČ UKS-1 Uređaj za uzemljenje kolskog sloga lokomotive Nazivna struja In = 200A (400A,1 min.) EARTHING DEVICE UKS-1 Earthing device for electric locomotive Rated current In = 200A (400A,1 min.) UZEMLJIVAČ UKS-2 Uređaj za uzemljenje kolskog sloga lokomotive Nazivna struja In = 600A EARTHING DEVICE UKS-2 Earthing device for electric locomotive Rated current In = 600A UZEMLJIVAČ OS-XV/A Otpornik za uzemljenje kolskog sloga putničkih kola EARTHING RESISTOR OS-XV/A Earthing resistor for passenger coaches 6

7 IZOLATOR KPI-30 Provodni izolator sa strujnim transformatorom Nazivni napon Un = 30kV Nazivna struja In = 400A ROOF BUSHING INSULATOR KPI-30 Roof bushing insulator with current transformer Rated voltage Un = 30kV Rated current In = 400A IZOLATOR PIL-30 Potporni izolator Nazivni napon Un = 30kV Fn = 15000N POST INSULATOR PIL-30 Post insulator Rated voltage Un = 30kV Fn = 15000N UPRAVLJANI DC/DC PRETVARAČ EPK-110 Ulazni napon Uin = 110V (77-135V) Izlazni napon Uout = 0-110V Izlazna struja Iout = 1A(max.) CONTROLLED DC/DC CONVERTOR EPK-110 Input napon Uin = 110V (77-135V) Output voltage Uout = 0-110V Output Current Iout = 1A(max.) UZEMLJIVAČ URU-1 Uređaj za rastavljanje i uzemljenje na putničkim kolima EARTHING DEVICE URU-1 Earthing and disconnecting device for passenger coaches 7

8 ELEKTROPNEUMATSKI VENTILI EP-10 - EP-20 - EP-30 Nazivni napon Un = V Pn = 0-12 bar Qn = mm 2 MAGNET VALVES EP-10 - EP-20 - EP-30 Rated voltage Un = V Pressure Pn = 0-12 bar Qn = mm 2 ELEKTROPNEUMATSKI VENTILI EVP-1 Nazivni napon Un = V Pn = 0 12 bar MAGNET VALVES EVP-1 Rated voltage Un = V Pressure Pn = 0 12 bar OTPORNIK OS-XI/A Otpornik za elektrodinamičko kočenje električne lokomotive sa prinudnim hlađenjem Nazivni napon Un = 1000V Nazivna struja In = 1000A R = 2 x 0,65Ω RESISTOR OS-XI/A Resistor for electrodinamical braking of electrical locomotive with forced cooling Rated voltage Un = 1000V Rated current In = 1000A R = 2 x 0,65Ω OTPORNIK OS-IX/G Otpornik za uzemljenje Nazivni napon Un = 1000V Nazivna struja In = 5A R 1 = 0,8Ω R 2 = 1,5Ω R 3 = 40,0Ω RESISTOR OS-IX/G Earthing resistor Rated voltage Un = 1000V Rated current In = 5A R 1 = 0,8Ω R 2 = 1,5Ω R 3 = 40,0Ω 8

9 OTPORNIK OS-IX/B Otpornik za šantiranje vučnih motora sa prinudnim hlađenjem Nazivni napon Un = 1000V Nazivna struja In = 800A OTPORNIK OS-IX/E Otpornik za elektrodinamičko kočenje električne lokomotive sa prinudnim hlađenjem Nazivni napon Un = 1000V Nazivna struja In = 1000A R = 0,42Ω RESISTOR OS-IX/B Shunting resistor for traction motors with forced cooling Rated voltage Un = 1000V Rated current In = 800A RESISTOR OS-IX/E Resistor for electrodinamical braking of electrical locomotive with forced cooling Rated voltage Un = 1000V Rated current In = 1000A R = 0,42Ω OTPORNIK OS-XIV/A Otpornik za elektrodinamičko kočenje električne lokomotive sa prinudnim hlađenjem Nazivni napon Un = 1000V Nazivna struja In = 1000A R = 3 x 0,42Ω OTPORNICI Otpornici za uzemljenje neutralne tačke (zvezdišta) transformatora OS-XV/B R = 4Ω Nazivna struja In = 60A (300A, 5 sek.) OS-XV/C R = 100Ω Nazivna struja In = 16A (80A, 5 sek.) RESISTOR OS-XIV/A Resistor for electrodinamical braking of electrical locomotive with forced cooling Rated voltage Un = 1000V Rated current In = 1000A R = 3 x 0,42Ω RESISTORS Earthing resistors for transformer neutral point OS-XV/B R = 4Ω Rated current In = 60A (300A, 5 sec.) OS-XV/C R = 100Ω Rated current In = 16A (80A, 5 sec.) 9

10 METALNI OTPORNIK ZA UZEMLJENJE NEUTRALNIH TAČAKA OK-II 6kV 20Ω OK-III 6kV 400Ω OK-IV 12kV 40Ω METAL-ENCLOSED EARTHNING RESISTOR FOR TRANSFORMER NEUTRAL POINT OK-II 6kV 20Ω OK-III 6kV 400Ω OK-IV 12kV 40Ω ELEKTROMAGNETNA ŠINSKA KOČNICA MŠK-V/A Nazivni napon Un = 24V jss Nazivna struja In = 41A Privlačna sila Fn = 84kN ELECTROMAGNETIC RAIL BRAKE MŠK-V/A Rated voltage Un = 24V DC Rated current In = 41A Attractive force Fn = 84kN ELEKTROMAGNETNA ŠINSKA KOČNICA MŠK-I/D Nazivni napon Un = 24V jss Nazivna struja In = 43A Privlačna sila Fn = 75kN ELECTROMAGNETIC RAIL BRAKE MŠK-I/D Rated voltage Un = 24V DC Rated current In = 43A Attractive force Fn = 75kN PREKIDAČI I KONTROLERI PP-2K, PP-4 Pregibni dvopolni i četveroploni prekidači Nazivni napon Un =600V; 24V Nazivna struja In = 1A; 25A SWITCH PP-2K, PP-4 Two and four - pole switch Rated voltage Un = 600V; 24V Rated current In = 1A; 25A 10

11 UREĐAJ ZA PREKLAPANJE UP-4Sg Za grejanje putničkih kola Nazivni napon Un = 3000V jss Nazivna struja In = 10A SWITCHING DEVICE UP-4Sg For passenger coaches heating Rated voltage Un=3000V DC Rated current In = 10A KONTAKTI Razne vrste kontakata CONTACTS All kinds of contacts KONTAKT Kontaktni element Nazivni napon Un=3000V jss Nazivna struja In = 10A CONTACT Contact element Rated voltage Un=3000V DC Rated current In = 10A KONTAKT DKE-6 Kontaktni element Nazivni napon Un = 2400V Nazivna struja In = 300A CONTACT DKE-6 Contact element Rated voltage Un = 2400V Rated current In = 300A 11

12 KONTAKT DKE-5 Kontaktni element Nazivni napon Un = 600V Nazivna struja In = 300A CONTACT DKE-5 Contact element Rated voltage Un = 600V Rated current In = 300A GLAVNI ISPRAVLJAČ ZA EMV SERIJE JŽ 412/416 Diodni ispravljač za glavni pogon vučnih motora Nazivni napon Un = 1800V Nazivna struja In = 800A ESTEL MINEL ELVO POMOĆNI PRETVARAČ ZA PUTNIČKA KOLA CONVERSTAT II 4U 46K Transfer tehnologije ALSTOM MINEL ELVO realizovan preko ŽTP Beograd MAIN RECTIFIER FOR EMU JŽ 412/416 Traction diode rectifier Rated voltage Un = 1800V Rated current In = 800A ESTEL MINEL ELVO AUXILIARY CONVERTER FOR PASSENGER COACHES CONVERSTAT II 4U 46K Technology transfer ALSTOM MINEL ELVO realised via ZTP Beograd ISPITNA STANICA Trajna snaga 300kW Kontinualna promena napona do 4500V jss Kratkotrajno 1 MW TEST CELL Power 300kW continiously Controlled voltage up to 4500V DC Short time 1 MW 12

13 INVERTOR SPN 74/240 Pretvarač za napajanje klima uređaja na dizelelektričnim lokomotivama Ulazni napon: Uin = 74VDC ( )VDC Izlazni napon: Uout = 240VAC±1% Nominalna snaga: Pn = 2500VA CONVERTER SPN 74/240 Auhiliary converter for driving air-conditioner on diesel loccos. Input voltage: Uin = 74VDC ( )VDC Output voltage: Uout = 240VAC±1% Rated Power: Pn = 2500VA INVERTOR SPN 24/230 ( HWR ) Pretvarač namenjen za napajanje rashladnih uređaja u vagon restoranima Ulazni napon: Uin = 24VDC (16,8 30)VDC Izlazni napon: Uout = 230VAC±1% Nominalna snaga: Pn = 800 VA CONVERTER SPN 24/230 ( HWR ) Auhiliary converter for driving cooling devices on board of passanger coaches. Input voltage: Uin = 24VDC (16,8 30)VDC Output voltage: Uout = 230VAC±1% Rated Power: Pn = 800 VA INVERTOR SPN 600/240 Pretvarač namenjen za napajanje klima uređaja na tramvaju. Ulazni napon: Uin=600 VDC ( )VDC Izlazni napon: Uout = 240 VAC±1% Nominalna snaga: Pn = 2500 VA CONVERTER SPN 600/240 Auhiliary converter for driving air-conditioner on tramways. Input voltage: Uin=600VDC( )VDC Output voltage: Uout = 240 VAC±1% Rated Power: Pn = 2500 VA 13

14 MINEL ELVO je specijaliziran za: - inžinjering - projektovanje i konstruisanje - proizvodnju električne opreme - održavanje i remont - trgovinu - kontrolu kvaliteta za vozni park: - električne lokomotive - elektromotorne vozove - dizel-električne lokomotive - industrijske i rudničke lokomotive - putničke vagone - tramvaje - trolejbuse MINEL ELVO a.d. Beograd, Tošin bunar 268? General Manager: 381(11) , ? Sales department: 381(11) , Tel / fax: 381(11) , 381(11) office@minel-elvo.co.yu web: MINEL ELVO is specialized in: - engineering - design and construction - manufacture of electric equipment - industrial repair and overhaul - trade - quality control for rolling stock: - electric locomotives - electromotive trains - disel-electric locomotives - industrial and mining locomotives - passenger coaches - trams - trolley busses ME 2005/10 14

DC DC CONVERTER 1000W 100-400VDC Input / 12VDC Output

DC DC CONVERTER 1000W 100-400VDC Input / 12VDC Output DC DC CONVERTER 1000W 100-400VDC Input / 12VDC Output Code prod. : 30x57090.00 Feb, 11 th 2005 MES DEA s.a. - Service - Copying of this document and giving it to others and the use or communication of

More information

Welcome to the presentation of the Hybrid Trolley-Bus

Welcome to the presentation of the Hybrid Trolley-Bus Welcome to the presentation of the Hybrid Trolley-Bus Fitted with an electrical combined storage unit and used for Public Transportation O-Bus Nr. 029, Typ: ÖAF Gräf & Stift NGE 152 M17 hybrid, BBG Eberswalde,

More information

TRAMS TROLLEY-BUSES SUBWAY

TRAMS TROLLEY-BUSES SUBWAY 9 FT-100-600 Traction Inverter for Asynchronous Drives 11 FT-105-600 Traction Inverter for Asynchronous Drives 13 FT-170-600 Traction Inverter for Asynchronous Drives 15 FT-300-600 Traction Inverter for

More information

22 November 2007 Sinaia

22 November 2007 Sinaia 22 November 2007 Sinaia LEKOV, a.s. Romania public transport Why we are here??? We offer... solution to any application adaptability, tailor made design replacement of original pantographs in Milano assistance

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

MOBILNA TRANSFORMATORSKA STANICA. 132 kv, 25 MVA

MOBILNA TRANSFORMATORSKA STANICA. 132 kv, 25 MVA This document remains the exclusive property of the KONČAR POWER PLANT AND ELECTRIC TRACTION ENGINEERING Inc. Reproduction or any use not in conformity with the intended application is not permissible.

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Efficient recovery of braking energy through a reversible dc substation

Efficient recovery of braking energy through a reversible dc substation Efficient recovery of braking energy through a reversible dc substation DANIEL CORNIC Senior R&D Engineer. Alstom Transport Daniel.Cornic@transport.alstom.com Abstract The full regeneration of the braking

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion Rectifiers Microprocessor controlled rectifier technology Fully adjustable float, boost and equalizing charge modes with V/I characteristic Advanced technology for phase control Verylowvoltage ripple and

More information

Analysis of fuel cell

Analysis of fuel cell Analysis of fuel cell commuter rail vehicles Stuart Hillmansen*1 1, D Meegahawatte1, C Roberts, P Jennings2, A McGordon2; 1University of Birmingham, United Kingdom, 2University of Warwick, United Kingdom

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Power transformers. Special transformers Railway

Power transformers. Special transformers Railway Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together

More information

Hybrid shunter locomotive

Hybrid shunter locomotive Hybrid shunter locomotive 1 Hervé GIRARD, Presenting Author, 2 Jolt Oostra, Coauthor, 3 Joerg Neubauer, Coauthor Alstom Transport, Paris, France 1 ; Alstom Transport, Ridderkerk, Netherlands 2 ; Alstom

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information

Auxiliary Relay. Type P8n, PQ8n, PN8n

Auxiliary Relay. Type P8n, PQ8n, PN8n Auxiliary Relay Type P8n, PQ8n, PN8n ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

MITRAC 500. Driven by Reliability. Propulsion & Controls

MITRAC 500. Driven by Reliability. Propulsion & Controls MITRAC 500 Driven by Reliability Propulsion & Controls MITRAC Low Power exceeding your expectations The BOMBARDIER* MITRAC* 500 product portfolio is a family of propulsion systems for light rail vehicles

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un.

Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un. Rev. - 2004-10-22 Page 1(5) General RXTBA 1 is a three-phase phase sequence voltage filter built up by resistors and capacitors. The filter is available in two voltage variants; one for rated voltage 3x110

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

ELECTRONIC POWER SYSTEMS

ELECTRONIC POWER SYSTEMS ELECTRONIC POWER SYSTEMS TRADEOFFS BETWEEN SINGLE-PHASE & THREE-PHASE POWER WHITE PAPER: TW0057 1 Executive Summary Modern Electronic Systems are quite often powered from a three-phase power source. While

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off. Diode Applications Diode Switching As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off. Voltage Rectifier A voltage rectifier is a circuit that converts an

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52 Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail

More information

How To Use The Vacon 0 Machinery

How To Use The Vacon 0 Machinery vacon 0 machinery how would you like your ac drive today? easy adaptation for customer requirements The Vacon 0 Machinery is an extremely compact AC drive for machine builders in the power range from 0.25

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Automatic Voltage Regulator User s Manual

Automatic Voltage Regulator User s Manual Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright

More information

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose

More information

*.ppt 11/2/2009 12:48 PM 1

*.ppt 11/2/2009 12:48 PM 1 Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers

More information

EFC 3600. Frequency converters

EFC 3600. Frequency converters 2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

Catalog Edition 2014. DIN-Rail components for rolling stock applications

Catalog Edition 2014. DIN-Rail components for rolling stock applications Catalog Edition 014 DIN-Rail components for rolling stock applications 1 3 4 5 6 7 8 9 10 11 1 13 14 15 16 17 18 CDC00053D004 DIN Rail components for rolling stock applications DIN-Rail components for

More information

Kinetic energy recovery on railway systems with feedback to the grid

Kinetic energy recovery on railway systems with feedback to the grid Kinetic energy recovery on railway systems with feedback to the grid Authors: J.M. ORTEGA, METRO DE BILBAO;S:A: H. IBAIONDO, A. ROMO. INGETEAM TRACTION,S.A. 1. Introduction The increasing concern with

More information

VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls

VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls TM TM INSTALLATION AND OPERATING INSTRUCTIONS VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls Model KBWM-120 rated 1/100-1/3 HP (90 Volts DC) @ 115 Volts AC, 50/60 Hz Model KBWM-240 rated

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt TDB106015en/05.2013 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

More information

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc. Crydom RHP Series 3 Phase Hybrid Solid State Contactor By Paul Bachman Fellow Engineer, Crydom, Inc. ABSTRACT Solid State Relays and Contactors (SSRs) have been available in one form or the other for over

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

Electric Power in Airplane. Student: Maja Knezev Course ELEN 615, 31 st August 2006

Electric Power in Airplane. Student: Maja Knezev Course ELEN 615, 31 st August 2006 Electric Power in Airplane Student: Maja Knezev Course ELEN 615, 31 st August 2006 Power sources on aircraft engine driven AC generators, auxiliary power units (APUs), external power and ram air turbines.

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Type SA-1 Generator Differential Relay

Type SA-1 Generator Differential Relay ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-348.11C Effective: November 1999 Supersedes I.L. 41-348.11B, Dated August 1986 ( ) Denotes

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V 110 220

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V 110 220 Armature 6- This manual is to be given to the end user 1 T5 Field Slow fuse 250V 8 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 220 T3 quency T10 50Hz 60Hz LAM 13 %

More information

Three-phase AC circuits

Three-phase AC circuits Three-phase AC circuits This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,

More information

ebus-high Power Charging Solutions from Siemens

ebus-high Power Charging Solutions from Siemens Krefeld, 20.04.2015 ebus-high Power Charging Solutions from Siemens siemens.com Siemens ebus infrastructure Introduction "ebus infrastructure" part of urban transport within Mobility Division Global HQ

More information

ESS industry day Introduction to Imtech Power Conversion

ESS industry day Introduction to Imtech Power Conversion ESS industry day Introduction to March 12 th, 2014 Erwin Lenten Royal Imtech N.V. is a technical services provider in Europe in electrical services, ICT and mechanical services Turnover 5.4 billion, 29,000

More information

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

How To Understand The Electrical Power Supply Of A Power Supply System

How To Understand The Electrical Power Supply Of A Power Supply System 17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Modern electrical propulsion systems for rolling stock

Modern electrical propulsion systems for rolling stock odern electrical propulsion systems for rolling stock Athen, January 2006 Andreas Fuchs TS GT DP Copyright Siemens AG 2005. All Rights Reserved. TS GT DP, Fuchs Folie odern electrical propulsion systems

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0

More information

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 24/2500 SECTIONS English 1 Nederlands 21 Deutsch 45 This page intentionally left blank. Subject to change without notice AT22500E / 151195

More information

COMPACT POWER TWIN RELAY

COMPACT POWER TWIN RELAY FTR-K1 SERIES COMPACT POWER TWIN RELAY 1 POLE x 2-25A, H-Bridge (for automotive applications) FTR-P4 Series FEATURES Compact for high density packaging High contact capacity with proven contact material

More information

Single-Phase AC Synchronous Generator

Single-Phase AC Synchronous Generator ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description

More information

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EEM 102 INTRODUCTION TO ELECTRICAL ENGINEERING EXPERIMENT 9: DIODES AND DC POWER SUPPLY OBJECTIVE: To observe how a diode functions

More information

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin

More information

Installation and Operating Manual

Installation and Operating Manual DC DRIVE BC138 BC139 DC CONTROL Installation and Operating Manual 7/2001 MN708 TABLE OF CONTENTS Section Page i. Simplified Operating Instructions.......................................... 1 ii. Safety

More information

hybrid fuel cell bus

hybrid fuel cell bus hybrid fuel cell bus PURE EMOTION PURE capacity The full passenger capacity of a standard diesel bus seats 34 standees 70 (7 passengers per sqm) total 104 Thanks to the three axles of the Van Hool A330

More information

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract. USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS Abstract This application note describes the necessary procedure to use a standard Pacific Power Source Model

More information

MULTIFUNCTION TIME RELAY CRM-93H

MULTIFUNCTION TIME RELAY CRM-93H 4 MULTIFUNCTION TIME RELAY CRM-93H - 10 functions Features: Universal supply voltage AC/DC 12-240V 10 functions: - 5 time functions controlled by supply voltage - 4 time functions controlled by control

More information

Step Voltage Regulators

Step Voltage Regulators Step Voltage Regulators Don Wareham Field Application Engineer Today s Agenda Introduction Voltage Regulator theory Voltage Regulator application considerations Installation and proper bypassing Wrap-up/questions

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual Patented Ultra Fast CL Circuit Prevents Demagnetization in PM Motors Installation and Operating Instructions

More information

Products and solutions for lifting systems

Products and solutions for lifting systems Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded

More information

J1000. System configuration

J1000. System configuration YASKAWA JZ J1000 The basic inverter V/f controlled inverter Good torque performance (150% / 3 Hz) Double rating ND 120%/1min and HD 150%/1 min Overload detection function (150% during 60s) thermal function

More information

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

ROLLING STOCK MAINTENANCE REPAIR & OVERHAUL (MRO) Turbo Power Systems Capability & Services

ROLLING STOCK MAINTENANCE REPAIR & OVERHAUL (MRO) Turbo Power Systems Capability & Services ROLLING STOCK MAINTENANCE REPAIR & OVERHAUL (MRO) Turbo Power Systems Capability & Services Table of Contents TPS Overview Corporate Transportation Sector MRO Experience History and Pedigree Portfolio

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Electrical Symbols and Line Diagrams

Electrical Symbols and Line Diagrams Electrical Symbols and Line Diagrams Chapter 3 Material taken from Chapter 3 of One-Line Diagrams One-line diagram a diagram that uses single lines and graphic symbols to indicate the path and components

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical

More information

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear. OVERCURRENT & EARTH FAULT RELAYS Objective: To study the protection of equipment and system by relays in conjunction with switchgear. Theory: The function of a relay is to detect abnormal conditions in

More information

General-purpose Relay

General-purpose Relay General-purpose Relay An Improved Miniature Power Relay with Many Models for Sequence Control and Power Applications A wide range of relay variations including ones with operation indicators, high-capacity

More information

Pilot-wire differential relay for lines with two or more terminals

Pilot-wire differential relay for lines with two or more terminals Pilot-wire differential relay for lines with two or more terminals Page 1 Issued: March 2003 Revision: A Data subject to change without notice Pilot-wire differential relay with RXHL 401 Features Phase

More information

SX460. Generator Automatic Voltage Regulator Operation Manual

SX460. Generator Automatic Voltage Regulator Operation Manual SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.

More information

How To Build A Low Voltage Capacitor Lvcp

How To Build A Low Voltage Capacitor Lvcp Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3 2 Phase Stepping Motor Driver 2M542 OPEATING MANUAL Table of contents Introduction page 2 Specifications page 2 Timing chart page 3 Setting page 4 Current set page 4 educe current function page 4 Micro

More information

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012 TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets 17th April 2012 Session 2 Technological challenges to cope with in TWENTIES field tests

More information

Inverter / Charger Installation General Operations and AC and DC Connections

Inverter / Charger Installation General Operations and AC and DC Connections Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information