AIR LINE VALVES AND GAUGES
|
|
- Tyler Joseph
- 7 years ago
- Views:
Transcription
1 AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand carries a full line of durably built valves, strainers, and pressure gauges that ensure you ve got the power you need when you need it. 1
2 2 INGERSOLL-RAND AIR LINE VALVES AND GAUGES BALL VALVES Provide extended service life and resist failure caused by severe temperature applications Full-flow design assures maximum system efficiency Highly inert PTFE seats provide resistance to chemical corrosion Two Viton o-rings at the stem provide maximum safety with no maintenance Blow-out proof system, chrome-plated brass ball, and specifically designed handle enable increased turning leverage for easy opening and closing Available in female pipe sizes Ball Valves Part Number Size NPT B L M N D Ball Valves /2" 0.98" 5.1" 2.32" 1.69" 0.59" /4" 1.22" 5.98" 2.52" 1.97" 0.75" " 1.57" 6.32" 3.19" 2.13" 0.945" /4" 1.93" 8.05" 3.66" 3.98" 1.18" /2" 2.13" 8.23" 4.02" 4.43" 1.5" " 2.69" 8.58" 4.76" 5.02" 1.89" /2" 3.35" 13.11" 6.14" 5.2" 2.52" " 3.89" 13.52" 6.97" 5.51" 3" Please be aware that ball valves are intended for use in the fully open or closed positions. Depending on application conditions, throttling of the valve may result in premature seal failure and/or inability to turn the valve handle
3 INGERSOLL-RAND AIR LINE VALVES AND GAUGES 3 ARO-STOP VALVE ARO-STOP valves shut off air to pump when material containers are empty or fluid lines are broken. They also feature quick-set and reset capabilities. ARO-STOP Valves Part Air Inlet Number NPT (F) ARO -STOP Valves Air Outlet NPT (F) *Maximum flow rate of psi. Pressure Range psi (bar) * 1/4" 1/4" (1.4 12) /2" 1/2" (1.4 12) Protect Your Investment Pump runaway results when your material container is depleted and the pump cycles fast and needlessly. Protect your pump investment with an ARO -STOP valve. For Use With Thunder Series, Series 200, & 1/2" diaphragm pump (includes connecting hose) Series 425, Series 600, & 1" diaphragm pump LOW LEVEL CUT-OFF Low level cut-off prevents air from entering the fluid line by closing the pump intake when material supply is exhausted. Cut-off also threads to the bottom of siphon tube for immersion in fluid, and serves as a check valve. Low Level Cut-off For Use With Low Level Cut-off* Series 200 and Series 425 pumps with 1-1/2" NPT (F) threads, Thunder Series 3" air motor pumps *Not for pumps that exceed 6 gpm. PRESSURE RELIEF VALVE / VALVE KIT Pressure Relief Valve / Valve Kit Part Description Number Pressure Relief Valve / Valve Kit Pressure relief valve is used on material outlet side of pump to automatically allow bleed-back of material to container in applications where thermal expansion is present Pressure relief valve kit includes relief valve reducing bushing, compression coupling, 3' of plastic drain tubing, & grommet
4 4 INGERSOLL-RAND AIR LINE VALVES AND GAUGES PIPE LINE VALVE A sturdy, quick-acting valve that goes from full flow to off with only a 1/4 turn. Pipe Line Valve NPT Description Pipe Line Valve C /4" 4-way shut-off valve PIPE LINE AIR STRAINERS Our strong and efficient air strainers are designed to permit free passage of air. They can be cleaned quickly by removing the plug from the strainer cap and turning air on momentarily. Pipe Line Air Strainers Female NPT Pipe Line Air Strainers EU-A267 3/4" HU-A267AT 1" K4U-A267AT 1-1/4" ST /2" ST "
5 INGERSOLL-RAND AIR LINE VALVES AND GAUGES 5 PRESSURE GAUGES Pressure Gauges NEEDLE PRESSURE GAUGE Pressure Rating psi kpa Port Size Dial Size Mounting Type Pressure Gauges " 2.5" Center back mount " 2.5" Center back mount " 2.5" Center back mount " 2.5" Center back mount " 2.5" Center back mount " 2.5" Lower mount " 4" Lower mount , " 2.5" Center back mount , " 2.5" Center back mount , " 2.5" Lower mount , " 4" Lower mount , " 2.5" Center back mount , " 2.5" Lower mount , " 4" Lower mount , " 2.5" Center back mount , " 4" Lower mount ,000 7, " 2.5" Center back mount ,000 7, " 4" Lower mount ,500 10, " 2.5" Center back mount ,000 14, " 2.5" Center back mount ,000 20, " 2.5" Center back mount ,000 60, " 2.5" Center back mount Pressure gauges are critical to any installation. Ingersoll-Rand offers a full range (15 psi 10,000 psi) of liquid-filled pressure gauges. Ingersoll-Rand gauges are built in a durable stainless steel case with a vent plug and copper alloy fittings. Needle Pressure Gauge Needle Pressure Gauge NPG-A1 NPG-2 Description Gauge kit Needle & cleaning wire kit Utilizing our needle pressure gauge is one of the simplest ways to check actual air pressure of the equipment while it is operating, determining whether or not the equipment is receiving adequate air pressure. The hypodermic needle easily pierces any size rubber air hose, and, if properly inserted, will not cause a leak when withdrawn. The Ingersoll-Rand needle pressure gauge kit consists of a convenient carrying pouch, an easy-to-read pressure gauge, a needle guard, two hypodermic needles, and two cleaning wires.
HYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
More information400B SERIES DIAPHRAGM PUMP
400B SERIES DIAPHRAGM PUMP In today s agricultural and industrial markets, isn t it good to know that you can rely on one name Sotera to fit your chemical transfer needs? The Sotera 400B Series offers
More informationPRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
More informationMustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More informationMany Products...One Source
PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K
More informationREGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
More informationFleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationPC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
More informationSIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
More informationAir/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application:
/Vacuum Valves Micro-Irrigation and vacuum control is essential to the safety, longevity, efficiency, and performance of an irrigation system. must be allowed to exit pipelines 1) upon startup to prevent
More informationSPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES
ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION
More informationSection 8 Storage Tanks & Equipment
Section Storage Tanks & Equipment Table of Contents Section Storage Tanks & Equipment Above Ground Horizontal Tanks... -1-4 Containment Sumps...-5 Fillrite AC & Transfer Pumps... -9-10 Fillrite Diesel
More informationELECTRIC/DIESEL FIRE PUMP CHECK LIST
BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested
More informationENGINE COOLING SYSTEM
ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,
More information5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationInstallation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
More informationPC1130 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
More informationIndirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
More informationFILLING AND PURGING THE SYSTEM
FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationProduct Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationAUTOMATIC CHANGEOVER MANIFOLD Series 915
AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm
More informationVe-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
More informationPipe Valves, Fittings and Nipples Pressures to 15,200 psi
Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by
More informationPRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM
PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM PRESSURE REDUCER AND RELIEF VALVES These devices are used to reduce and control a gaseous flow pressure (air, steam, gas ). The PRESSURE
More informationAKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
More informationAir Conditioning & Refrigeration Master Catalog. Catalog CIC-2003-1/USA April 2003
Air Conditioning & Refrigeration Master Catalog Catalog CIC-2003-1/USA April 2003 Table of Contents Table of Contents Service Valves Frontseating Valves... page 115 RB01 Series Ball Valves... page 117
More informationOperators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
More informationAMX300 DirectConnect Mixing Valve Kits
AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates
More informationComplete Systems & Parts Automatic Oiler & Grease Bank
MADE IN THE USA Complete Systems & Parts Automatic Oiler & Grease Bank www.gosuburban.com 2 Lubrication Systems Lubrication Systems, a division of Suburban Manufacturing, manufactures a complete line of
More informationBERMAD Fire Protection
400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
More informationFloat and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
More informationConstantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
More informationCHEMICAL CLEANING UNIT Product number: 737189
CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2
More informationSteam System Best Practices Condensate System Piping
Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum
More informationMASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder
MASTER CYLINDER Master Cylinder The master cylinder converts the motion of the brake pedal into hydraulic pressure. It consists of the reservoir tank, which contains the brake fluid; and the piston and
More informationACCUMULATOR INSTALLATION
7001-7 ACCUMULATOR INSTALLATION BRAKE ACCUMULATORS I 308L93 Rae 7-59710 Issued 6-93 Printed in U.S.A 7001-8 Removal ACCUMULATOR VALVE 1. Park the machine on a level surface and lower the. loader bucket
More informationModulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.
Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,
More informationFUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com
OUR PARTS PUT YOU IN THE PASSING LANE FUEL SYSTEMS Protect your fuel system. Velvac offers a wide range of locking fuel caps and anti-siphon tubes to keep unlawful occurances at bay. With OEM approved
More information- Do not immerse cords, pump or any electrical wire or device in water or other liquid.
TRANSFER PUMP INSTRUCTIONS FOR THE SUPER TRANSFER PUMP 1. Pump (water may be present in the pump and lines due to testing at factory) 2. Instructions. 3. Inlet thicker wall hose (1), outlet hose (1) 4.
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for
More informationNITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
More informationSELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationInstallation, Maintenance, & Repair Series 4000B/LF4000B
Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using
More informationMedical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
More information3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide
", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,
More informationMorrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
More informationHL Series - Commercial Heaters Tankless Water Heating Solutions
HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage
More informationNFPA31FuelOilPiping 1 Revised 3-1-11
NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from
More informationCDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
More informationStyle 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description
Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard
More informationBERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features
Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,
More informationINSTALLATION INSTRUCTIONS GEO-BOOSTER TM
Table of Contents General Description 1 Parts list 1 Installation 2 New Ground Loop 2 Retrofit 4 Temporary 6 Troubleshooting 8 INSTALLATION INSTRUCTIONS GEO-BOOSTER TM General Description The Geo-Booster
More informationENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...
FUEL FILTER............................ FUEL HEATER.......................... INJECTOR.............................. SUPPLY PUMP.......................... COMMON RAIL.......................... FUEL PRESSURE
More informationFluid Monitoring and Inventory Management
SECTION FOUR Fluid Monitoring and Inventory Management Introduction Alemite meets your fluid monitoring and inventory management needs with its Accu-Guard systems and its Bigview Tank Monitor. These systems
More informationINSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS PARTS LIST
12501 Telecom Drive, Tampa Florida 33637 INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS PARTS LIST 90/4.5.1 Rev.1 CONSTANTEMP LOW PRESSURE STEAM-WATER HEATERS Models E-1500L, E-1520L, E-300L, E-320L,
More informationHose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
More informationWaste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
More informationRAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID
More informationVALVES FOR REFRIGERATING SYSTEMS
VALVES FOR REFRIGERATING SYSTEMS FROM QUALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel Quality Range of Products is
More informationTECHNICAL DATA. Dry 122a. November 12, 2013
Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model
More informationTRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007
TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES 301.010 ANNUAL SERVICE TEST FOR FIRE HOSE EFFECTIVE: OCTOBER 2007 The Department will test all fire hose annually. The testing of fire hose determines its serviceability.
More informationHydraulic Trouble Shooting
Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More information4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
More informationHOSE KIT #17-Isolator Y 1/2" to 2" Sizes DESCRIPTION
HOSE KIT #17-Isolator Y 1/2" to 2" Sizes and Isolator B Union Ball Valve with combination Pressure/Temperature Test Valve and manual air vent (CPTA) Isolator Y with (1) Pressure/Temperature Test Valve
More informationRegulator Options and Accessories
Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,
More informationAPCO SLOW CLOSING AIR/VACUUM VALVES
BULLETIN 1 JULY 01 APCO SLOW CLOSING AIR/VACUUM VALVES Series 1900 APCO Slow Closing Air/Vacuum s Maximum Air Flow Velocity in Good Pipeline Design The Air/Vacuum operates in the normal fashion allowing
More informationAccumulators and Receivers
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Accumulators and Receivers Catalog C-1, October 2007 Page 2 / Catalog
More informationWHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
More informationNAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
More informationBERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features
Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive
More informationUsed Fluid Handling Portable Used-Oil Gravity Drains
Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More informationModel 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
More information08 General Purpose Pumps
70 08 General Purpose Pumps INTRODUCTION Ballast Pumps Today s wakeboard and ski tow boats need to be able to take on water ballast to modify their wake formation. A development of our tried and tested
More informationThe Silencer. Silencer Outdoor Air Blower, The Name That Says It All. Quality Product. Call 1-800-848-3077 for more information
The Silencer The Silencer is our most popular outdoor-rated air blower for one simple reason. It s quiet! Turn on your Silencer day or night, and you won t disturb the neighbors or ruin your relaxing spa
More informationWATER PRESSURE REDUCING VALVES
MADE IN THE USA WATER PRESSURE REDUCING VALVES TABLE OF CONTENTS PRODUCT PAGE How Pressure Reducing Valves Work 3 36 Series 4 36C Series 6 36H Series 8 AUTOMATIC PRESSURE REDUCTION Pressure reducing valves
More informationMidwest Industrial Tanks
FOR AGRICULTURE AND INDUSTRY Midwest Industrial Tanks Fuel & Oil Storage Solutions Midwest Industrial Tanks Is Your Source For All Of Your Fuel Storage And Fuel Transportation Needs. Our Satisfied Customers
More informationInstallation, Operation, Repair and Parts Manual
2088 Agricultural Series Pumps Installation, Operation, Repair and Parts Manual Form 911-396 6/11, Rev. A Description Model 2088-343-135 Automatic-Demand Pumps / 12 VDC These SHURflo 2088 Series diaphragm
More informationYELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail
YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail NEW Valve core tool page 35 EXPANDED LINE Quick couplers page 36 33 1/4" 4-IN-1 BALL VALVE TOOL for vacuum, charge, cores and recovery
More informationUSER MANUAL. 10 GPM Small Single Line Cryogenic Coupling
JC Carter LLC LNG Couplings USER MANUAL 10 GPM Small Single Line Cryogenic Coupling Models 50E722 Nozzle and 50E721 Receptacle User s Manual and Installation Guide! Warning: Read the User s Manual and
More informationAIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
More informationAdvanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler
Advanced Heating & Hot Water Systems A Trailblazing Energy Star Listed Boiler that Installs like a Mid-Efficiency Boiler with the Performance of a High-Efficiency Product Ultra High Efficiency Energy Star
More informationINSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
More informationWatts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
More informationVSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
More informationTY-FLO Needle Valves
Design/Features Hard (Vee) or Delrin Soft Seat/Tip Orifice sizes from.17 to.438 in. Flow Coefficients (C V ) from.37 to.7 Straight or angle flow patterns Optional panel mount Handle options available Non-wetted
More informationTABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationType 92S Pilot-Operated Steam Regulator
Type 92S Pilot-Operated Steam Regulator Introduction The Type 92S steam regulator is piston actuated for high cycle steam service which includes a Type 6492L, 6492H or pilot (see Figure 1). These pilots
More informationball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
More informationSpill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container
Spill Containers 517 Series 3 ½ Gallons AST Spill Container Installed on aboveground storage tanks for the purpose of containing small spills and drips from the fill nozzle. 3 ½ gallon capacity. Steel
More informationVacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology
Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides
More informationROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
More informationMono-Block II Installation & Operation Manual
Mono-Block II Installation & Operation Manual Enraf Fluid Technology UK, Ltd. Enraf Fluid Technology USA, Inc. 6 Pennant Park, Standard Way 2000 Northfield Court Fareham, Hampshire, England PO16 8XU Roswell,
More information