Drive Motor 1PV5135-4WS18

Size: px
Start display at page:

Download "Drive Motor 1PV5135-4WS18"

Transcription

1 Drive Motor 1PV5135-4WS18 AC Induction Motor 300 V 50 KW A 190 A 10,000 rpm 90 kg 425 x 245 x 245 mm Torque & Power vs. Speed 350 A / 193A / 300DC) Mmax [Nm] Mcont [Nm] Pmax [kw] Pcont [kw] Torque [Nm] Nm Nm Nm Nm Nm Nm 5 25 Nm Speed [1/min] KW 130 KW 120 KW 110 KW 100 KW 90 KW 80 KW 70 KW 60 KW 50 KW 40 KW 30 KW 20 KW 10 KW 0 KW 10000

2 Drive Motor 1PV5135-4WS28 AC Induction Motor 650 V 67 KW A 300A 124 A 10,000 rpm 90 kg 425 x 245 x 245 mm Torque & Power vs. Speed 300 A / 124A / 650 V) Mmax [Nm] Mcont [Nm] Pmax [kw] Pcont [kw] KW KW KW Torque [Nm] KW 90 KW 75 KW 60 KW 45 KW KW 5 15 KW Speed [1/min] KW 10000

3 Drive Motor 1PV5135-4WS24 AC Induction Motor 520 V 61 KW A 145 A 10,000 rpm 90 kg 425 x 245 x 245 mm M_max (300A) M_cont P_max P_cont kw 35 M_max P_max 140 kw Motor Torque [Nm] M_cont P_cont 120 kw 100 kw 80 kw 60 kw 40 kw Motor Power [kw] 5 20 kw 0 kw Motor Speed [rpm]

4 Drive Motor 1PV5138-4WS24 AC Induction Motor 650 V 85 KW A 142 A 10,000 rpm 120 kg 510 x 245 x 245 mm Torque and Power vs. Speed of Motor 300 A, / 140A / 685 V DC Mmax [Nm] Mcont [Nm] Pmax [kw] Pcont [kw] KW KW KW KW KW KW KW KW KW KW KW 5 15 KW 0 KW

5 Drive Motor 1PV5138-4WS20 AC Induction Motor 500 V 70 KW 205 Nm 250A 300A 170 A 9,000 rpm 120 kg 510 x 245 x 245 mm 40 M_max 160 KW 35 P_max 140 KW KW Torque [Nm] M_cont P_cont 100 KW 80 KW 60 KW Power [kw] KW 5 20 KW 0 KW Speed [rpm]

6 Generator 1FV5135-6WS36 PM Synch. Generator 650 V rpm 225 Nm A 4,000 rpm 86 kg 425 x 245 x 245 mm M max M cont P max P cont kw kw Torque [Nm] kw 60 kw 40 kw Power [kw] 5 20 kw 0 kw 0 rpm 500 rpm 1000 rpm 1500 rpm 2000 rpm 2500 rpm 3000 rpm 3500 rpm 4000 rpm Speed [rpm]

7 Generator 1FV5139-6WS28 PM Synch. Generator 650 V rpm A 170 A 4,000 rpm 120 kg 560 x 245 x 245 mm M_max 200 KW 180 KW Drehmoment [Nm] Torque [Nm] M_cont P_max P_cont 160 KW 140 KW 120 KW 100 KW 80 KW 60 KW Leistung [kw] Power [KW] KW 5 20 KW 0 KW Drehzahl Speed [rpm] [1/min]

8 Generator 1FV5168-8WS24 PM Synch. Generator 650 V rpm 265 A 360A 265 A rpm 180 kg 590 x 300 x 300 mm [Nm] [Nm] [kw] Max. Power [kw] Torque [Nm] 1000,0 900,0 800,0 700,0 600,0 500,0 400,0 300,0 200,0 100,0 0,0 300,0 270,0 240,0 210,0 180,0 150,0 120,0 90,0 60,0 30,0 0, Speed [rpm] Power [kw]

9 PRELIMINARY PEM-Motor 1DB2016 WS54 PM Synch. Motor 650 V rpm 210 A 350A 210 A rpm < 350 kg 510 x 510 x 500 mm PEM Motor V DC, 1 x 350A Mmax Mcont Pmax Pnenn kw kw Torque [Nm] kw 90 kw 60 kw kw 0 kw Speedl [rpm]

10 PRELIMINARY PEM-Motor 1DB2022 WS36 PM Synch. Motor 650 V rpm 320 A 600A 300 A rpm 480 kg 620 x 510 x 500 mm PEM Motor 1DB2022-W V DC, 2 x 300A Mmax Mcont Pmax Pnenn Torque [Nm] kw 240 kw 210 kw 180 kw 150 kw 120 kw 90 kw 60 kw 30 kw 0 kw Speedl [rpm]

11 PEM-Motor 1DB2024 WS36 PM Synch. Motor 750 V rpm 360 A 640A 360 A rpm 500 kg 660 x 510 x 500 mm Torque & Power vs. Speed Curve M_max_750VDC Nm Mcont_750VDC P_max_750VDC kw P_cont_750VDC Motor Torque 5000, 4500, 4000, 3500, 3000, 2500, 2000, 1500, 1000, 500, 500,0 kw 450,0 kw 400,0 kw 350,0 kw 300,0 kw 250,0 kw 200,0 kw 150,0 kw 100,0 kw 50,0 kw Motor Power 0, 0,0 kw 0,0rpm 500,0rpm 1000,0rpm 1500,0rpm 2000,0rpm 2500,0rpm 3000,0rpm 3500,0rpm Motor Speed

12 Auxiliary Drive Motor 1PV5131-4WS52 AC Induction Motor (8 l/min) V 20 KW / rpm 65 Nm (< rpm) 90A 54 A 5,000 rpm 54 kg 320 x 245 x 245 mm IP Mcont 30 [Nm] Pcont [KW] Speed [rpm] 0

13 Auxiliary Drive Motor 1PV5131-4WS28 AC Induction Motor (8 l/min) V 1) 15 KW / rpm 47 Nm (< rpm) A 80 A 5,000 rpm 54 kg 320 x 245 x 245 mm IP 54 Note 1: DC voltage fits for special auxiliary concept for seriell two auxiliary motor operation Torque & Power vs. Speed (1PV A / 80 A / 220 V DC) Mmax [Nm] Mcont [Nm] Pmax [kw] Pcont [kw] Torque [Nm] KW 45 KW 40 KW 35 KW 30 KW 25 KW 20 KW 15 KW 10 KW 5 KW 0 KW Power [kw] Speed [1/min]

14 DC-DC / IGBT MONO Inverter Operating Voltage DC Inverter Inverter (460V AC) Max. Current Inverter (10 s) Max. Power (500V AC) Switching Frequency Inverter Chopper or DCDC Switching Frequency Chopper & DCDC Dim. (wxlxh) without Connectors Inverter 3 Phases & 1 Phase for Chopper or DC/DC converter 650 V 300 V V 250 A 200 KVA 350 A 320 KVA 2-6 KHz 1 x 150A (@ 6 khz) 1 x 300A (@ 0 khz) 2-6 KHz 30 kg 411 x 454 x 183 mm IP 6K9K - 25 C to 50 C (for rated values)

15 Reactor Circuit Operating Voltage DC Capacity (Intermediate Circuit) Inductance Max. Current Frequency Dim. (wxlxh) Reactor Circuit Single Phase 650 V 110 V V 1 mf 1 mh 140 A DC-Current 115 A at 6kHz 300 A 2-10 khz approx. 50 kg 411 x 454 x 183 mm IP 6K9K - 40 C to 70 C

16 Flender Summation Gearbox Nominal ratio Maximum traction torque per motor Input shaft Output shaft Max. Input Speed Max. Output Speed Mounting Angle Flender 152 air 4.05:1 170 KW 47 DIN 5480 ISO ,000 rpm 2,467 rpm 100 kg 7.5 (+0.8 / -0.4 ) - 25 C to 45 C

17 DICO Vehicle Interface Power Supply Outputs ESX LT 9 32 V 4x digital Output HS 2,5A 4x digital Output LS 1,5A 4x PWM Output HS 4A 10V reference Output 400mA Inputs Communication Interface Dimensions Protection Class 8x digital Input (HS or LS) 8x multiple Input (ANL, HS, LS) 2 x CAN-Bus 154,4 x 173 x 52,5 (mm) 1 kg IP67-40 C to 85 C

18 Change Index Version Change Name Date Copy_DataSheet..._AF.pp Reactor Circuit: : 50kg, Ambient Temp: -40 C C t Holl DS_Comp_AG.ppt Include the file name in order to see the source if we make custom specific pdf'sholl DS_Comp_AH.ppt Deleted Details like WS12 on the data sheets Holl DS_Comp_AI.ppt Generator Data for WS02 corrected Holl DS_Comp_AI.ppt Datasheet "Flender Summation Gearbox" and "DICO" added; Holl DS_Comp_AJ.ppt Datasheet PEM Motor DB2024 corrected Holl DS_Comp_AK.ppt Datasheet PEM Motor DB2016 included Holl DS_Comp_AL.ppt Datasheet PEM Motor DB2022 included Holl DS_Comp_AM.ppt Datasheet PEM Motor DB2016&22 corrections Holl

TRAMS TROLLEY-BUSES SUBWAY

TRAMS TROLLEY-BUSES SUBWAY 9 FT-100-600 Traction Inverter for Asynchronous Drives 11 FT-105-600 Traction Inverter for Asynchronous Drives 13 FT-170-600 Traction Inverter for Asynchronous Drives 15 FT-300-600 Traction Inverter for

More information

Frequency Converter Fv

Frequency Converter Fv 2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)

More information

EFC 3600. Frequency converters

EFC 3600. Frequency converters 2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation

More information

SBL/K Motor Catalogue 2002

SBL/K Motor Catalogue 2002 SBL/K Motor Catalogue 2002 Brushless Servomotors up to 32Nm Motor Technology Ltd. Motec House Chadkirk Ind. Est. Romiley Stockport Cheshire SK6 3LE England Tel. +44(0)161 427 3641 Fax. +44(0)161 427 1306

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

Datasheet of the Easy Servo Motor ES-M Series

Datasheet of the Easy Servo Motor ES-M Series Datasheet of the Easy Servo Motor ES-M Series Stepper Motor with Encoder, 0.9-8 Nm Version 1.3 http://www.leadshine.com Descriptions Leadshine s ES-M series easy servo motors, or stepper motors with encoders,

More information

Datasheet of the Easy Servo Motor ES-MH Series

Datasheet of the Easy Servo Motor ES-MH Series Datasheet of the Easy Servo Motor ES-MH Series High Voltage Stepper Motor with Encoder, 8-20 Nm Version 1.4 http://www.leadshine.com Descriptions Leadshine s ES-MH series easy servo motors, or stepping

More information

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for

More information

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER

More information

Servo drives. Compact converter IndraDrive Cs

Servo drives. Compact converter IndraDrive Cs Compact converter IndraDrive Cs 2 Bosch Rexroth AG Electric Drives and Controls Documentation Highly versatile, extremely compact drives Power range 100 W to 9 kw Multi-protocol-enabled, Ethernet-based

More information

High-Voltage Insulated DC/DC Power Supply ISO3116I for gate drivers for 4.5kV and 6.5kV IGBTs

High-Voltage Insulated DC/DC Power Supply ISO3116I for gate drivers for 4.5kV and 6.5kV IGBTs High-Voltage Insulated DC/DC Power Supply ISO3116I for gate drivers for 4.5kV and 6.5kV IGBTs The ISO3116I is a single-channel insulated DC/DC converter suitable as a power supply for IGBT drivers up to

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

D.C. Motors. Products and specifications subject to change without notice.

D.C. Motors. Products and specifications subject to change without notice. D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

1 Temperature Derating Guide

1 Temperature Derating Guide VLT HVAC Drive FC 02 Application Note Temperature Derating Guide Temperature Derating Guide.. Abstract This paper provides detailed data regarding the operation of the VLT HVAC Drive FC02 at varying ambient

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

ECO 80 PRODUCT DESCRIPTION FEATURES. Power output S1 100% Adjustable air nozzle. Liquid cooling. Minimalmengenschmierung MMS retrofit

ECO 80 PRODUCT DESCRIPTION FEATURES. Power output S1 100% Adjustable air nozzle. Liquid cooling. Minimalmengenschmierung MMS retrofit A PRODUCT DESCRIPTION Power output S6 40% Power output S1 100% Rotation speed Diameter Spindlehousing Spindle interface 3.0 kw 2.5 kw to 40.000 rpm 80 mm Stainless steel HSK - E25 FEATURES Adjustable air

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l D C S e r v o S y s t e m s RH Mini Series Total Motion Control Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l Precision Gearing & Motion Control DC SERVO ACTUATORS

More information

What Is Regeneration?

What Is Regeneration? What Is Regeneration? Braking / Regeneration Manual Regeneration Overview Revision 1.0 When the rotor of an induction motor turns slower than the speed set by the applied frequency, the motor is transforming

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information

Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S

Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S New Products Introduction Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S Takashi Sekiguchi Masahiro Kidou Yuusuke Shimura Yuji Ide Masahisa Koyama Michio Kitahara

More information

Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems

Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems Power Supply Components Battery Chargers Inverters and Converters Date: May 2011

More information

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations.

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

motion solutions for leisure, mobility and industrial applications www.parvalux.com

motion solutions for leisure, mobility and industrial applications www.parvalux.com motion solutions for leisure, mobility and industrial applications www.parvalux.com designed for application bespoke DC gear-motor solutions 2 STAIR LIFT unique worm-spur double reduction gearbox delivering

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

BMD. Permanent Magnet AC Synchronous Motors

BMD. Permanent Magnet AC Synchronous Motors BMD Permanent Magnet AC Synchronous Motors Power, control and green solutions About us 3 Bonfiglioli, one name for a large international group. It was back in 1956 that Clementino Bonfiglioli established

More information

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction This inverter can be used in parallel with two different operation modes. 1. Parallel operation in single phase with up to

More information

4KVA/5KVA Parallel Installation Guide

4KVA/5KVA Parallel Installation Guide 4KVA/5KVA Parallel Installation Guide 1. Introduction This inverter can be used in parallel with two different operation modes. 1. Parallel operation in single phase with up to 4 units. The supported maximum

More information

ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw

ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw Solar inverters ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw ABB s central inverters are extremely scalable, modular-inverter systems that are based on 55kW modular

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive Simulation and Analysis of PWM Inverter Fed Induction Motor Drive C.S.Sharma, Tali Nagwani Abstract Sinusoidal Pulse Width Modulation variable speed drives are increasingly applied in many new industrial

More information

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM Page 1 of 19 Cat Electronic Technician 2015A v1.0 Product Status Report 2:49 PM Product Status Report Parameter Value Product ID WRK00337 Equipment ID WRK00337 Comments A01-52 C9 330D (THX37891) Parameter

More information

WIND TURBINE TECHNOLOGY

WIND TURBINE TECHNOLOGY Module 2.2-2 WIND TURBINE TECHNOLOGY Electrical System Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 2005 Nadi, Republic of the Fiji Islands Contents Module 2.2 Types of generator systems

More information

Application Note TMA Series

Application Note TMA Series 1W, SIP, Single & Dual Output DC/DC Converters Features SIP Package with Industry Standard Pinout Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77 x 0.4 x 0.24 ) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77 x

More information

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation. PRELIMINARY TECHNICAL INFORMATION Three-phase Digital SCR Firing Board HIGHLIGHTS - Up to 480 V AC input supply voltage - Up to 700 V AC sync input - DSP controlled - Digital or analog input signaling

More information

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input

More information

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

Programmable Single-/Dual-/Triple- Tone Gong SAE 800 Programmable Single-/Dual-/Triple- Tone Gong Preliminary Data SAE 800 Bipolar IC Features Supply voltage range 2.8 V to 18 V Few external components (no electrolytic capacitor) 1 tone, 2 tones, 3 tones

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

28V, 2A Buck Constant Current Switching Regulator for White LED

28V, 2A Buck Constant Current Switching Regulator for White LED 28V, 2A Buck Constant Current Switching Regulator for White LED FP7102 General Description The FP7102 is a PWM control buck converter designed to provide a simple, high efficiency solution for driving

More information

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01 INTEGRATED CIRCUITS DATA SHEET File under Integrated Circuits, IC01 May 1992 GENERAL DESCRIPTION The is a monolithic integrated circuit for mono FM portable radios, where a minimum on peripheral components

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage Description SDD-AAPNP is the programmer for non-dali Inventronics drivers, and the programmer and calibrator for the following intelligent controllers: SDD-AAPNx Dimming Signal Attenuator TDD-ANPNx Combo

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48 Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 0, RS 8 Zero switching AC Solid State Relay Direct copper bonding (DCB) technology in 25A and 0A types LED indication Clip-on IP 20 protection

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light

More information

PowerFlex Dynamic Braking Resistor Calculator

PowerFlex Dynamic Braking Resistor Calculator Application Technique PowerFlex Dynamic Braking Resistor Calculator Catalog Numbers 20A, 20B, 20F, 20G, 22A, 22B Important User Information Solid-state equipment has operational characteristics differing

More information

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529) Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads: Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

www.curtisinstruments.com

www.curtisinstruments.com CANBUS I/O EXPANSION MODULE MODELS 56 / 56P FEATURES Eighteen multi-purpose I/O pins provide simple, flexible vehicle control system expansion. Two high-frequency (A, A) PWM driver outputs support a variety

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-H

TECHNICAL DATASHEET Incremental Encoder RI 58-H Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided. Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current

More information

Principles of Adjustable Frequency Drives

Principles of Adjustable Frequency Drives What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable

More information

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data

More information

3-PHASE STEPPING MOTOR. VRDM 39x. Document: 100000116 Edition: d013, 2005.02

3-PHASE STEPPING MOTOR. VRDM 39x. Document: 100000116 Edition: d013, 2005.02 -PHASE STEPPING MOTOR VRDM 9x Edition: d, 5. Features common to all motor types Test voltage to DIN EN 64 part Insulation class F Run-out and perpendicularity to DIN 4955 N Paint: black RAL 95 Security

More information

High speed, deep deflux operation, heat rise limited. Series inductance Lseries = 0 mh. Maximum drive voltage Vdrive

High speed, deep deflux operation, heat rise limited. Series inductance Lseries = 0 mh. Maximum drive voltage Vdrive High speed, deep deflux operation, heat rise limited Motor Type MotorCode "U313C35.20.3" = Slosstot = 684.7734 watt Series inductance Lseries = 0 mh Cooling = "water + glycole cooling" Coolindex Maximum

More information

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Variable Frequency Drives - a Comparison of VSI versus LCI Systems Variable Frequency Drives - a Comparison of VSI versus LCI Systems Introduction TMEIC is a leader in the innovative design and manufacture of large ac variable f requency drive systems. TMEIC has been

More information

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry. The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion

More information

Borstlösa DC-motorer. Promoco Scandinavia AB

Borstlösa DC-motorer. Promoco Scandinavia AB Borstlösa DC-motorer Promoco Scandinavia AB BL Series Brushless DC Motors with Integral Drive 24, 54, 68, and 70 mm diameters, 2W up to 110W output power Allied Motion s BL series of small brushless DC

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

Design of an Auxiliary Power Distribution Network for an Electric Vehicle

Design of an Auxiliary Power Distribution Network for an Electric Vehicle Design of an Auxiliary Power Distribution Network for an Electric Vehicle William Chen, Simon Round and Richard Duke Department of Electrical & Computer Engineering University of Canterbury, Christchurch,

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs. TXV - Presentation pumps with Load Sensing control variable displacement piston pumps ADVANTAGES pumps are variable displacement with pressure-flow control called Load Sensing. They self-regulate to give

More information

Series 6000 Torque measured metal bellow coupling

Series 6000 Torque measured metal bellow coupling Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement

More information

Solar Cybertech: A Competition of Digitally Controlled Vehicles Poweredby Solar Panels

Solar Cybertech: A Competition of Digitally Controlled Vehicles Poweredby Solar Panels 118 ELECTRONICS, VOL. 17, NO. 2, DECEMBER 2013 Solar Cybertech: A Competition of Digitally Controlled Vehicles Poweredby Solar Panels O. García, J. A. Oliver, D. Díaz, D. Meneses, P. Alou, M. Vasić, J.

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95 Actuators Technical data sheet 227S-230-05-S1 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Plug-in relays Mini ISO relays

Plug-in relays Mini ISO relays Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Actuators and positioning drives

Actuators and positioning drives Actuators and positioning drives distributed by www.laumans.com Actuators and positioning drives FlexiDrive product range type MDBA 42 MSQA 46 MSAA 42 Actuator Actuator Actuator motor brush DC motor brush

More information

C Standard AC Motors

C Standard AC Motors C Standard AC Standard AC C-1 Overview, Product Series... C-2 Constant... C-9 C-21 C-113 Reversible C-147 Overview, Product Series Constant Reversible Electromagnetic Brake C-155 Electromagnetic Brake

More information