precision glass capillary viscometers

Size: px
Start display at page:

Download "precision glass capillary viscometers"

Transcription

1 precision glass capillary viscometers

2 ASTM Ubbelohde Suitable for measuring transparent liquids. High precision & easy to use. Nominal overall length 283 mm; approximate sample volume 18 ml. Complete with ISO certificate of calibration. U-Tube Reverse Flow Viscometers Suitable for measuring opaque liquids. Type BS/IP/RF. Nominal overall length 275 mm; approximate sample volume ml. Complete with ISO certificate of calibration. 1643/01 O to /02 OC to /03 OB to / to /05 1C to /06 1B to / to /08 2C to /09 2B to / to 1, /11 3C to 3, /12 3B 5.0 1,000 to 5, / ,000 to 10, /14 4C 30 6,000 to 30, /15 4B 50 10,000 to 50, / ,000 to 100, / to / to / to / to / to / to 1, / to 3, / ,000 to 10, / ,000 to 30, / ,000 to 100, / ,000 to 300,000 Cannon-Fenske Routine Suitable for measuring transparent liquids. Calibration data stated at 40 & 100ºC. Nominal overall length 250 mm; approximate sample volume 7 ml. Complete with ISO certificate of calibration. Cannon-Fenske Opaque Suitable for measuring opaque liquids. Calibration data stated at 40 & 100ºC. Nominal overall length 295 mm; approximate sample volume 12 ml. Complete with ISO certificate of calibration. 1634/ to / to / to / to / to / to / to / to / to / to / to / to / to / to / to / to / to 1, / to 1, / to 2, / to 2, / ,600 to 8, / ,600 to 8, / ,000 to 20, / ,000 to 20, / ,000 to 50, / ,000 to 50, / ,000 to 100, / ,000 to 100,000 PSL Rheotek offers a comprehensive range of precision calibrated glass capillary viscometers. Viscometers are made by our experienced glass blowers from high grade borosilicate glass tubing. PSL Rheotek viscometers are used by refinery, testing and research laboratories throughout the world and enjoy a high reputation for quality workmanship and accuracy of calibration.

3 Cannon-Ubbelohde Viscometers Suitable for transparent liquids. Nominal overall length 335mm, approximate sample size 11 ml. Complete with ISO certificate of calibration. Suspended-Level Viscometers Suitable for measuring transparent liquids. Type BS/IP/SL Nominal overall length 330mm; approximate sample volume ml. Complete with ISO certificate of calibration. 1647/ to / to / to / to / to / to / to / to / to 1, / to 2, / ,600 to 8, / ,000 to 20, / ,000 to 45, / ,000 to 100, / to /02 1A to / to /04 2A to / to 1, /06 3A to 3, / ,000 to 10, /08 4A 30 6,000 to 30, / ,000 to 100,000 Suspended-Level Viscometers, Shortened Form Suitable for measuring transparent liquids. Type BS/IP/SL Nominal overall length 250mm; approximate sample volume 10 ml. Complete with ISO certificate of calibration. 1628/ min 1628/ to / to / to / to / to / to 1, / to 3, / ,000 to 10,000 Miniature Suspended-Level Viscometers Suitable for measuring transparent liquids. Type BS/IP/MSL Nominal overall length 330mm; approximate sample volume 4 ml. Complete with ISO certificate of calibration. 1631/ to / to / to / to / to / to 1, / to 3,000 Viscometer calibration is performed on-site by our UKAS accredited ISO calibration laboratory. The PSL Calibration Laboratory maintains a master viscometer scale in accordance with ASTM D2162. All calibration data us directly traceable to international standards.

4 Cannon-Manning Vacuum Capillary Viscometer Suitable for measuring the dynamic viscosity of bituminous binders. Nominal overall length 245 mm. Calibrated in accordance with EN and ASTM D2171. Part No. Size Constant Range (Pa.s) 1676/ to / to / to / to / to / to / to / to / to / to / to 8000 Note: Nominal constant for bulb B is shown for illustration purposes. Asphalt Institute Vacuum Capillary Viscometer Suitable for measuring the dynamic viscosity of bituminous binders. Nominal overall length 245 mm. Calibrated in accordance with EN and ASTM D2171. Range (Pa.s) 1677/ to / to / to / to / to /06 400Rc to /07 800Rc to Note: Nominal constant for bulb B is shown for illustration purposes. Modified Koppers Vacuum Capillary Viscometer Suitable Suitable for for measuring measuring the the dynamic dynamic viscosity viscosity of of bituminous bituminous binders. binders. Nominal Nominal overall overall length length mm. mm. Calibrated Calibrated in in accordance accordance with with EN EN and and ASTM ASTM D2171. D2171. Vacuum System for bituminous binders Complete with vacuum controller, vacuum pump, valve control module and glass bottle. Range (Pa.s) 1678/ to / to / to / to / to Note: Nominal constant for bulb B is shown for illustration purposes. Part No / /02 Description Bitumen Vacuum System 240V / 50Hz Bitumen Vacuum System 110V / 60Hz PSL Rheotek bitumen viscometers are suitable for measuring a wide range of liquid asphalts, bituminous binders and asphalt cements. For vacuum capillary viscometers, a bitumen vacuum system is available. Other accessories include viscometer bath, silicone bath oil and viscosity oil standards.

5 U-Tube Viscometers Suitable for measuring transparent liquids. Type BS/U - Nominal overall length 300 mm, approximate sample volume ml. Complete with ISO certificate of calibration. 1619/00 O to /01 A to /02 B to /03 C to /04 D to /05 E to /06 F to 1, /07 G to 3, /08 H 10 2,000 to 10,000 Cannon Manning Semi-Micro Viscometers Type ASTM Suitable for transparent liquids. Nominal overall length 275 mm; approximate sample volume 1 ml. Complete with ISO certificate of calibration. 1659/ to / to / to / to / to / to / to / to / to 1, / to 2, / ,600 to 8, / ,000 to 20,000 Miniature U-Tube Viscometers Suitable for measuring transparent liquids. Type BS/U/M - Nominal overall length 250 mm, approximate sample volume 4 ml. Complete with ISO certificate of calibration. 1622/01 M to /02 M to /03 M to /04 M to /05 M to 100 Zeitfuchs Cross-Arm Viscometers Type ASTM Nominal overall length 295 mm; approximate sample volume up to 3 ml. Complete with ISO certificate of calibration. 1663/ to / to / to / to / to / to 1, / to 3, / ,000 to 10, / ,000 to 30, / ,000 to 100,000 PSL Rheotek glass capillary viscometers are suitable for a wide range of applications. Applicable petroleum testing methods include ASTM D445, D446, D2162, D2170, D2171, ISO 3104 & ISO3105. Other applications include polymers, cellulose, blood and plasma.

6 Accessories Metal Viscometer Holders Viscometer Bench Stand Part No Part No. Specifications 1850/A1 Universal Viscometer Holder 1818/A1 U-Tube Viscometer Holder Size O to F 1818/A2 U-Tube Viscometer Holder Size G & H 1824/A1 Suspended-Level Viscometer Holder Size 1 to /A2 Suspended-Level Viscometer Holder Size 4A & /A1 Suspended-Level Short Form Viscometer Holder 1833/A1 1836/A1 Cannon-Fenske Routine Viscometer Holder U-Tube Reverse Flow Viscometer Holder 1840/A1 1842/A1 1842/A2 Cannon-Fenske Opaque Viscometer Holder Ubbelohde Viscometer Holder Size 0 to 4 Ubbelohde Viscometer Holder Size 4C to 5 Plastic Viscometer Holders Part No. Specifications 1934/A1 Plastic holder for CF Routine & Opaque 1943/A1 Plastic holder for ASTM Ubbelohde (sizes O to 4) SCAN Viscometer Part No /Type C Part No /Type T Viscometer Bath PSL Master Viscometer. Part No series Precision Digital Thermometer Part No. TT3 TLC-250 Chiller Part No. TLC-250 TCB-7 Viscometer Bath Part No Other Viscometers available: Master Viscometers Scan Viscometers Ostwald Viscometers Suspended-Level dilution Viscometers Deoxyribonuclease Assay Viscometers Falling Sphere Viscometers

7 Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0) Fax: +44 (0) Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.

Viscometers. CANNON-FENSKE REVERSE FLOW VISCOMETER TYPE for opaque and transparent liquids

Viscometers. CANNON-FENSKE REVERSE FLOW VISCOMETER TYPE for opaque and transparent liquids 17 Viscometers For the determination of kinematic viscosity of transparent and opaque Newtonian liquids according to ASTM D 446, ISO 3104, IP 71, and BS 188. UBBELOHDE VISCOMETER for transparent and opaque

More information

LABORATORY. www.irmeco.de

LABORATORY. www.irmeco.de LABORATORY www.irmeco.de Cannon-Fenske Routine Cannon-Fenske Routine Viscometer according to ASTM D445-446, ASTM D2515, ISO 3104-3105 used for quick and easy measurement of the viscosities of transparent

More information

Viscosity. www.koehlerinstrument.com. Test Methods

Viscosity. www.koehlerinstrument.com. Test Methods Viscosity Test Methods Page Kinematic Viscosity of Transparent and Opaque Liquids ASTM D445; IP 71; ISO 3104; DIN 51550; FTM 791-305...2-13 Kinematic Viscosity of Asphalts (Bitumens) ASTM D2170...2-13

More information

Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens) 1

Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens) 1 Designation: D 2170 95 Designation: 319/84 (89) Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens) 1 This standard is issued under the fixed designation D 2170; the number immediately

More information

Ubbel. Viscometers and their range of use. Viscometer type. Cannon-Fenske reverse flow BS/IP-U tube reverse flow. Cannon-Fenske-Routine

Ubbel. Viscometers and their range of use. Viscometer type. Cannon-Fenske reverse flow BS/IP-U tube reverse flow. Cannon-Fenske-Routine Viscometers and their range of use Measurement substance property Viscometer type Ubbelohde Micro Ubbelohde TC Ubbelohde Ostwald Micro Ostwald Cannon-Fenske-Routine Cannon-Fenske reverse flow BS/IP-U tube

More information

Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability

Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability T h e r i g h t t e m p e r a t u r e w o r l d w i d e Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK code Coalville 6 Way North Cheshire Trading Estate Wirral CH43 3DU Contact: Mr D Williams Tel: +44 (0)151-649 9955 Fax: +44 (0)151-649 9977 E-Mail: sales@paragon-sci.com Website: www.paragon-sci.com Laboratory

More information

Catalogue 2012-2013. June2012, R1.0. Tamson Instruments

Catalogue 2012-2013. June2012, R1.0. Tamson Instruments Catalogue 2012-2013 June2012, R1.0 Content 1 ASTM Equipment...1 1.1 How to select the appropriate viscosity bath?... 6 1.2 ASTM D445 High Temperature Viscosity Baths... 7 1.3 Small and Precise Viscometer

More information

A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom

A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom The Civil Engineering Center 1 Visit www.ahm531.com for more lecture notes and E-book! The Civil Engineering Center 2 Visit www.ahm531.com for more lecture notes and E-book! Introduction : The grades of

More information

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best Lovis 2000 M/ME Microviscometer ::: Viscometry at its best Lovis 2000 M/ME is a rolling ball viscometer which unites an established measuring principle (Höppler, DIN 53015 and ISO 12058) with innovative

More information

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT CHAPTER 2: LIQUID VISCOSITY MEASUREMENT Objective Calculate viscosity (dynamic or absolute, and kinematic) and determine how this property varies with changes in temperature for a constant-composition

More information

POLYDIMETHYLSILOXANE

POLYDIMETHYLSILOXANE POLYDIMETHYLSILOXANE Prepared at the 37th JECFA (1990), published in FNP 52 (1992) superseding specifications prepared at the 29th JECFA (1985), published in FNP 34 (1986). Metals and arsenic specifications

More information

Standard Test Methods for Determination of Solution Viscosities of Polyamide (PA) 1, 2

Standard Test Methods for Determination of Solution Viscosities of Polyamide (PA) 1, 2 Designation: D 789 07 Standard Test Methods for Determination of Solution Viscosities of Polyamide (PA) 1, 2 This standard is issued under the fixed designation D 789; the number immediately following

More information

Standard Test Methods for Viscosity of Adhesives 1

Standard Test Methods for Viscosity of Adhesives 1 Designation: D 1084 97 Standard Test Methods for Viscosity of Adhesives 1 This standard is issued under the fixed designation D 1084; the number immediately following the designation indicates the year

More information

PENETRATION OF BITUMINOUS MATERIALS

PENETRATION OF BITUMINOUS MATERIALS NANYANG TECHNOLOGICAL UNIVERSITY School of Civil and Structural Engineering LABORATORY - PAVEMENT MATERIALS PENETRATION OF BITUMINOUS MATERIALS OBJECTIVES To examine the consistency of a sample of bitumen

More information

OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS

OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS Why Analyse Lubricants? With increasing costs and tighter deadlines, the need for effective maintenance strategies is greater than ever before. So why not

More information

PRODUCT GUIDE 2014. PRECISION INSTRUMENTS FOR Temperature, Density, Time, Weather and Calibration

PRODUCT GUIDE 2014. PRECISION INSTRUMENTS FOR Temperature, Density, Time, Weather and Calibration PRODUCT GUIDE 2014 PRECISION INSTRUMENTS FOR Temperature, Density, Time, Weather and Calibration TRIPLE ACCREDITED / REGISTERED ISO 9001:2008, ISO 14001:2004, ISO/IEC 17025:2005 Welcome to H-B Instrument

More information

Calibration Certificate

Calibration Certificate P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com SECTION 1: Page 1 of 7 Pages SECTION 2: APPROVED SIGNATORY Joseph Moran SECTION 3: PERSON PERFORMING

More information

DENSITY MEASURING SYSTEMS

DENSITY MEASURING SYSTEMS SHIBAYAMA SCIENTIFIC CO., LTD. DENSITY MEASURING SYSTEMS Density Gradient Tube Method Direct Reading Type A / Type B Comply with the standards below: JIS K-0061-1992, K-7112 1980 ASTM D1505 Type A /Left

More information

Trend Health Check & Monitoring Program - in-depth fluid condition analysis at laboratory

Trend Health Check & Monitoring Program - in-depth fluid condition analysis at laboratory Trend Health Check & Monitoring Program - in-depth fluid condition analysis at laboratory A thorough monitoring program is essential for an efficient preventive maintenance of your system. Our program

More information

How To Use An Irius Pid Detector

How To Use An Irius Pid Detector SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use

More information

Hello viewers welcome to lesson 4.7 which is on pavement materials part IV and in this lesson we will be covering bituminous binders.

Hello viewers welcome to lesson 4.7 which is on pavement materials part IV and in this lesson we will be covering bituminous binders. Introduction to Transportation Engineering Prof. K. Sudhakar Reddy Department of Civil Engineering Indian Institute of Technology, Kharagpur Lecture - 30 Pavement Materials IV Hello viewers welcome to

More information

Viscosity - Flow Cups. elcometer.com

Viscosity - Flow Cups. elcometer.com elcometer.com Viscosity - Flow Cups 1 Viscosity - Flow Cups Elcometer 2350 & 2354 Viscosity Flow Cups Viscosity Flow Cups are very easy to use instruments made of anodized aluminium with a stainless steel

More information

CATALOGUE REFERENCE MATERIALS

CATALOGUE REFERENCE MATERIALS IPT Institute for Technological Research CATALOGUE REFERENCE MATERIALS 2014 Laboratory of Metrological References IPT s Reference Materials www.ipt.br/nmr.htm Av. Prof. Almeida Prado n0 532 Predio 31 Cidade

More information

1. The Determination of Boiling Point

1. The Determination of Boiling Point 1. The Determination of Boiling Point Objective In this experiment, you will first check your thermometer for errors by determining the temperature of two stable equilibrium systems. You will then use

More information

Determination of Viscosity Using A Brookfield Viscometer for Conditioning Polymers

Determination of Viscosity Using A Brookfield Viscometer for Conditioning Polymers LUBRIZOL TEST PROCEDURE TP-N01004 Edition: December 2, 2013 Previous Editions: August 10, 2000 / November 1, 2011 Determination of Viscosity Using A Brookfield Scope A material's flow property is an important

More information

Viscosity. Desmond Schipper Andrew R. Barron. 1 Introduction

Viscosity. Desmond Schipper Andrew R. Barron. 1 Introduction OpenStax-CNX module: m50215 1 Viscosity Desmond Schipper Andrew R. Barron This work is produced by OpenStax-CNX and licensed under the Creative Commons Attribution License 4.0 Abstract This module discusses

More information

Flash Point. www.koehlerinstrument.com. Test Methods

Flash Point. www.koehlerinstrument.com. Test Methods Flash Point s Page Flash Point by Automatic Pensky-Martens Closed Tester ASTM D93; IP 34; ISO 2719; DIN EN 22719; NF M 07-019; JIS K2265...32 Flash Point by Automatic Abel Tester IP 170, 304; ISO 1523,

More information

The Safest Heating Method!

The Safest Heating Method! ACE Instatherm For Glass Vessels The Safest Heating Method! Borosilicate Glass Eliminate the need for heating tapes, immersion heaters and heating mantles. Instatherm is a safer, more precise heating method

More information

Viscosity (VIS) Topic: Mechanics. Laminar and turbulent flow, Reynolds number, Hagen-Poiseuille s law, Stokes law

Viscosity (VIS) Topic: Mechanics. Laminar and turbulent flow, Reynolds number, Hagen-Poiseuille s law, Stokes law Seite 1 Viscosity Topic: Mechanics 1 Key words Laminar and turbulent flow, Reynolds number, Hagen-Poiseuille s law, Stokes law 2 Literatur L. Bergmann, C. Schäfer, Lehrbuch der Experimentalphysik, Band

More information

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1 Designation: D562 01 (Reapproved 2005) Standard Test Method for Consistency of Paints Measuring Krebs Unit () Viscosity Using a Stormer-Type Viscometer 1 This standard is issued under the fixed designation

More information

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1. Characteristic: The process of pre-freezing and drying finishes in situ. The freeze dryer is equipped with observation windows and the drying process is intuitive. Silicone oil is as the medium and the

More information

Ultrasonic Reference Blocks

Ultrasonic Reference Blocks Ultrasonic Reference Blocks Custom and Standard Test Blocks for Nondestructive Testing Introduction 3 IIW Type 1 Calibration Block 4 Miniature Angle Beam (ROMPAS) Calibration Block 4 Distance Calibration

More information

Penetration. www.koehlerinstrument.com. www.koehlerinstrument.com. Test Methods

Penetration. www.koehlerinstrument.com. www.koehlerinstrument.com. Test Methods Test Methods Penetration of Bituminous Materials ASTM D5; IP 49; DIN 52010 Cone Penetration of Lubricating Grease ASTM D217; IP 50; ISO 2137; DIN 51804; FTM 791-311, FTM 791-313 Cone Penetration of Petrolatum

More information

HIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS

HIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS HIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS Research & Development Division RD/GN/032 June 2007 1. Purpose ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS

More information

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution The evaporating characteristics of hydrocarbons have an important effect on their performance. The

More information

MATRIX GEMINI LIMS AT WORK IN THE FOOD INDUSTRY

MATRIX GEMINI LIMS AT WORK IN THE FOOD INDUSTRY MATRIX GEMINI LIMS AT WORK IN THE FOOD INDUSTRY Real Time Traceability in Microbiology at Westward Laboratories Cornwall Quality is the Result "Using the configuration tools we have been able to update

More information

Viscosity Cup Reference Table 1

Viscosity Cup Reference Table 1 Viscosity Viscosity The extent to which a liquid resists a tendency to flow is defined as viscosity. In the coatings industry, this behaviour is one of the key parameters. Elcometer manufactures and supplies

More information

ROTOFIX 32 A Benchtop Centrifuge

ROTOFIX 32 A Benchtop Centrifuge ROTOFIX 32 A Benchtop Centrifuge ROTOFIX 32 A PERFORMANCE The ROTOFIX 32 A is a rugged, versatile and indispensable centrifuge for routine laboratory tasks in doctors practices and small hospitals. But

More information

NEW SMART STEAM DISTILLATION VAPODEST 200 VOLATILES SO 2 ALCOHOL PHENOLS KJELDAHL-N UNRIVALED EASE OF USE EFFICIENCY FUNCTIONS SAFETY

NEW SMART STEAM DISTILLATION VAPODEST 200 VOLATILES SO 2 ALCOHOL PHENOLS KJELDAHL-N UNRIVALED EASE OF USE EFFICIENCY FUNCTIONS SAFETY NEW VAPODEST 200 SMART STEAM DISTILLATION VOLATILES SO 2 ALCOHOL PHENOLS KJELDAHL-N C. Gerhardt proudly presents the brand new development of the successful VAPODEST line. Additional functions increase

More information

109 Adopted: 27.07.95

109 Adopted: 27.07.95 109 Adopted: 27.07.95 OECD GUIDELINE FOR THE TESTING OF CHEMICALS Adopted by the Council on 27 th July 1995 Density of Liquids and Solids INTRODUCTION 1. This guideline is a revised version of the original

More information

Oil Analysis. It is important that the sampling be done in the following manner: 1.

Oil Analysis. It is important that the sampling be done in the following manner: 1. Oil Analysis Introduction Oil analysis was originally used by the military and the railroad as a preventative maintenance program. It has expanded today to the fi eld of study called Tribology. Oil analysis

More information

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO)

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO) At a glance Anodized aluminium with a stainless steel orifice. For measuring the consistency of paints Expressed in second (s) flow time. Can be converted into centistokes. Available with adjustable stand.

More information

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used. STAGE MICROMETERS Introduction Whenever there is a need to make measurements with an eyepiece graticule, there is also a need to ensure that the microscope is calibrated. The use of a stage micrometer

More information

Determination of Ultra Low Chlorine (and Sulfur) in Oil

Determination of Ultra Low Chlorine (and Sulfur) in Oil Determination of Ultra Low Chlorine (and Sulfur) in Oil Application Note Key Benefits The X-Supreme8000 can be used as part of a quality control procedure to ensure petroleum products are manufactured

More information

How To Test A Titrette And Digital Burette

How To Test A Titrette And Digital Burette Titrette and Digital Burette (all models) Testing Instructions (SOP) May 2013 1. Introduction The standard ISO DIS 8655 describes both the design and the testing of bottle-top burette. The following Testing

More information

Electrical and mechanical interface requirements for separable HR, LR and LRM voltage detecting systems

Electrical and mechanical interface requirements for separable HR, LR and LRM voltage detecting systems C Metal-encapsulated switchgear installations, typically SF6 gas-insulated, have become widely accepted in the field of switchgear construction. In these types of installation, conventional voltage detectors

More information

Test equipment for temperature and its reduction

Test equipment for temperature and its reduction Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

FederalDemocratic RepublicofEthiopia

FederalDemocratic RepublicofEthiopia FederalDemocratic RepublicofEthiopia EDICTOFGOVERNMENT± Inordertopromotepubliceducationandpublicsafety, equaljusticeforal,abeterinformedcitizenry,therule oflaw,worldtradeandworldpeace,thislegaldocumentis

More information

VISCOSITY CLASSIFICATIONS

VISCOSITY CLASSIFICATIONS VISCOSITY CLASSIFICATIONS INDUSTRIAL LUBRICANT CASSIFICATIONS ISO (International Standards Organisation) viscosity classification The ISO viscosity classification uses mm 2 /s () units and relates to viscosity

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO)

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO) At a glance Anodized aluminium with a stainless steel orifice. For measuring the consistency of paints Expressed in second (s) flow time. Can be converted into centistokes. Available with adjustable stand.

More information

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No. 1203 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No. 1203 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS POLYVINYL ALCOHOL Prepared at the 68 th JECFA (2007) and published in FAO JECFA Monographs 4 (2007), superseding specifications prepared at the 63 rd JECFA (2004) and published in the Combined Compendium

More information

Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1

Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1 Designation: D 1298 99 e2 An American National Standard Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1 Designation: 160/99 Standard Test Method for Density, Relative Density

More information

World-Class Oil Sampling It is Possible

World-Class Oil Sampling It is Possible www.lubecontrol.com.au World-Class Oil Sampling It is Possible Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: info@lubecontrol.com.au

More information

Draeger-Tubes and accuro Pump

Draeger-Tubes and accuro Pump Draeger-Tubes and accuro Pump Trusted Technology that s ahead of its time Accurate Easy to read Flexible Fast Specific Easy to use Maintenance free Multi-Gas Detector accuro pump One handed operation What

More information

Measuring Extruders and Extrusiograph. ... where quality is measured.

Measuring Extruders and Extrusiograph. ... where quality is measured. Measuring s and... where quality is measured. Measuring s and Just Plug & Play The Plasti-Corder Lab-Station and Plastograph EC plus are the basic units for application oriented investigations or processing

More information

Color, True and Apparent

Color, True and Apparent Color, True and Apparent DOC316.53.01037 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 15 to 500 color units Scope and application: For water, wastewater and seawater; equivalent to NCASI method

More information

Portable digital microprocessor thermometers with interchangeable probes

Portable digital microprocessor thermometers with interchangeable probes JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Penetration. www.koehlerinstrument.com. www.koehlerinstrument.com. www.labomat.eu. Test Methods

Penetration. www.koehlerinstrument.com. www.koehlerinstrument.com. www.labomat.eu. Test Methods Test Methods Penetration of Bituminous Materials ASTM D5; IP 49; DIN 52010 Cone Penetration of Lubricating Grease ASTM D217; IP 50; ISO 2137; DIN 51804; FTM 791-311, FTM 791-313 Cone Penetration of Petrolatum

More information

ASTM Certified Glass Thermometers

ASTM Certified Glass Thermometers ASTM Certified Glass 8 Basic Unit Meets Strict Guidelines of the ASTM Provides Highly Accurate and Reproducible Measurements Variety of ASTM Applications Yellow Back with Permanent Markings for High Visibility

More information

PA94 Plus Basic. System Overview. Accessories/Options. PA94 Plus Basic Quick Release LDV Coupling 3338913. PA94 Plus Basic Fixed LDV 3350687

PA94 Plus Basic. System Overview. Accessories/Options. PA94 Plus Basic Quick Release LDV Coupling 3338913. PA94 Plus Basic Fixed LDV 3350687 PA94 Plus Basic PA94 Plus Basic System Overview PA94 Plus Basic Quick Release LDV Coupling 3338913 PA94 Plus Basic Fixed LDV 3350687 LDV Short Hose push in 3338700 LDV Short Hose M40 3338709 LDV Short

More information

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources PROVISIONAL The Source for Calibration Professionals Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources The NEW Advanced Range of Portable Temperature Calibrators Advanced Range Isotech

More information

limit to percentage levels, a limited working range translates

limit to percentage levels, a limited working range translates Figure 1. The AutoPrep 50 Automatic Dilution System. Figure 2. Schematic diagram of the AutoPrep 50. Flame atomic absorption spectroscopy (flame AA) is still the most frequently used instrumental technique

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

Color, True and Apparent

Color, True and Apparent Color, True and Apparent DOC316.53.01037 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 15 to 500 color units 5 to 500 color units (low range technique) Scope and application: For water, wastewater

More information

A U T O M O T I V E L I F T S

A U T O M O T I V E L I F T S Q U A L I T Y Y O U E X P E C T AT A P R I C E Y O U W O U L D N T T H E S TA N D A R D I N I N F O R M AT I O N, E Q U I P M E N T A N D D I A G N O S T I C S S Y S T E M S h t t p : / / d i a g n o s

More information

Standard Test Method for Water in Petroleum Products and Bituminous Materials by Distillation 1

Standard Test Method for Water in Petroleum Products and Bituminous Materials by Distillation 1 Designation: D 95 99 e1 An American National Standard American Association State Highway Transportation Standard AASHTO No. T55 Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 10.5

More information

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications: PERFORMANCE YOU CAN RELY ON NEW! Peltier Boost Technology TM Patented high-speed heating and cooling technology -25 to 420 C (-13 to 788 F) One Flashpoint Tester for All Applications: Fresh & used oils

More information

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by

More information

Particle Measurement Technology in Practice. From Theory to Application.

Particle Measurement Technology in Practice. From Theory to Application. Particle Measurement Technology in Practice. From Theory to Application. Page 3 1 Introduction to Particle Counting Page 19 2.4.2 General Installation Recommendations Page 3 Page 3 1.1 Physics Fundamentals

More information

EasyTrack 2 Accessories List

EasyTrack 2 Accessories List EasyTrack 2 Accessories List DATA LOGGER ET6061 EasyTrack2 Data Logger (6 Channel) Measurement Range -150 to 500 C (-238 F to 932 F) Accuracy ±0.5 C (0.9 F). Type K thermocouple. 6000 readings per channel.

More information

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these

More information

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals

More information

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen Laboratory Electrochemistry Products ph Conductivity Dissolved Oxygen Spoilt for choice Small footprint Adjustable viewing angle Wall mountable New style electrode holder Contents page Overview................................3

More information

HFM Heat Flow Meter Thermal Conductivity Analyzer

HFM Heat Flow Meter Thermal Conductivity Analyzer HFM Heat Flow Meter Thermal Conductivity Analyzer Introduction An insulating material is a material with low thermal conductivity, which in the construction industry, equipment manufacturing, or the production

More information

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL 1 of 8 The quality assurance plan as presented in the Quality Manual should assure that constant and consistent test conditions are met and verified and should be tailored to the laboratory s activities.

More information

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis VHG Labs, Inc. and Supplies for Spectrochemical Oil Analysis Section 1 Multi-Element Coolant Standard Coolant Standard The following standard is intended for use in the analysis of metals in ethylene glycol

More information

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.

More information

CSI Oil Analysis Options

CSI Oil Analysis Options Product Data Sheet L-OAOB-101105 October 2005 Machinery Health Management CSI Oil Analysis Options n CSI Oil Laboratory provides accurate and comprehensive industrial oil analysis results you can import

More information

What Can the OIL ANALYZERS Fluid Analysis Program Do For You?

What Can the OIL ANALYZERS Fluid Analysis Program Do For You? What Can the OIL ANALYZERS Fluid Analysis Program Do For You? Imagine being able to see exactly what s happening inside an engine, a gearbox or hydraulic system. OIL ANALYZERS Fluid Analysis is a preventive

More information

Copyright Warning & Restrictions

Copyright Warning & Restrictions Copyright Warning & Restrictions The copyright law of the United States (Title 17, United States Code) governs the making of photocopies or other reproductions of copyrighted material. Under certain conditions

More information

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications Flow Measurement Flow Switches Level Switches Level Interface Switches FCI OEM SERIES Industrial Machinery Chemical Injection

More information

DEHNshield Application-optimised multipole combined lightning current and surge arrester

DEHNshield Application-optimised multipole combined lightning current and surge arrester DEHshield Application-optimised multipole Application-optimised prewired combined lightning current based on spark gap technology simply equipped electrical installations with reduced technical requirements

More information

OPTICAL PARTICLE SIZER MASS CALIBRATION METHOD

OPTICAL PARTICLE SIZER MASS CALIBRATION METHOD OPTICAL PARTICLE SIZER MASS CALIBRATION METHOD APPLICATION NOTE OPS-001 The Optical Particle Sizer (OPS) is calibrated for size with Polystyrene Latex (PSL) spheres (per ISO 12501-1/4) at TSI. This method

More information

Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution

Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution Volatile Acids DOC316.53.01144 Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution Scope and application: For digestor sludges. 1 Adapted from The Analyst, 87, 949 (1962).

More information

Density/Specific Gravity/ Concentration Meter DMA 500

Density/Specific Gravity/ Concentration Meter DMA 500 Density/Specific Gravity/ Concentration Meter DMA 500 Density. It s that simple. Density measurement of liquids and gases is a proven method for analysis and quality control in numerous industries. It

More information

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA This is to signify that MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA Calibration Laboratory CL-151 has met the requirements of the IAS Accreditation

More information

Root ZX II Endodontic Predictability Apex Locator with Low Speed Handpiece. Thinking ahead. Focused on life.

Root ZX II Endodontic Predictability Apex Locator with Low Speed Handpiece. Thinking ahead. Focused on life. Root ZX II Endodontic Predictability Apex Locator with Low Speed Handpiece Thinking ahead. Focused on life. Root ZX II Key Features Endodontic Predictability As the world s best selling apex locator, Root

More information

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

haze-gard i The objective standard for a clear view Global communication Reliable and Precise haze-gard i The objective standard for a clear view Transparent products can have a milky or fuzzy appearance dependent on its light scattering behaviour. The haze-gard i quantifies the visual perception

More information

Titrette. class A precision. The next generation Digital Burette!

Titrette. class A precision. The next generation Digital Burette! The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, available in 10 ml, 25 ml, and 50 ml sizes, you can titrate quickly and

More information

Sampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved.

Sampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved. Sampling Solutions Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved. Oil Samples are used to obtain a clear indication of the operating status of your machinery. One of the most

More information

Viscosity: A Property of fluids 307-6 Compare the viscosity of various liquids 307-7 Describe factors that can modify the viscosity of a liquid 208-6

Viscosity: A Property of fluids 307-6 Compare the viscosity of various liquids 307-7 Describe factors that can modify the viscosity of a liquid 208-6 Viscosity: A Property of fluids 307-6 Compare the viscosity of various liquids 307-7 Describe factors that can modify the viscosity of a liquid 208-6 Design an experiment to test the viscosity of various

More information

GC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA. hmcnair@vt.edu

GC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA. hmcnair@vt.edu GC/MS Considerations for Fracking Gases and Water Dr. Harold McNair Virginia Tech Blacksburg, VA. hmcnair@vt.edu 1 Outline What is fracking? Energy, Economics, Environmental Factors Chromatographic Considerations

More information

Performance Graded Asphalt Binders Bob Horan, P.E. Consulting Engineer Mechanicsville, VA

Performance Graded Asphalt Binders Bob Horan, P.E. Consulting Engineer Mechanicsville, VA Performance Graded Asphalt Binders Bob Horan, P.E. Consulting Engineer Mechanicsville, VA October 30, 2003 T3S - Superpave for Low Volume Roads - R. Horan 1 What is Asphalt? October 30, 2003 T3S - Superpave

More information

X-SERIES THERMAL IMAGING CAMERAS

X-SERIES THERMAL IMAGING CAMERAS X-SERIES THERMAL IMAGING CAMERAS X380 THERMAL IMAGER The X-Series thermal imaging cameras powered by ISG technology provide firefighters with the ultimate combination of situational awareness, lightweight

More information

OT 40L / 90L. Laboratory Steam Sterilizers

OT 40L / 90L. Laboratory Steam Sterilizers OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture

More information

Your Service Partner Avonmouth and Bristol Service Centres

Your Service Partner Avonmouth and Bristol Service Centres Your Service Partner Avonmouth and Bristol Service Centres The Sulzer Advantage Avonmouth Service Centre Bristol Service Centre Capabilities Manual machining CNC machining Pump services Thermal spray

More information