Viscosity Cup Reference Table 1

Size: px
Start display at page:

Download "Viscosity Cup Reference Table 1"

Transcription

1 Viscosity Viscosity The extent to which a liquid resists a tendency to flow is defined as viscosity. In the coatings industry, this behaviour is one of the key parameters. Elcometer manufactures and supplies a wide range of viscosity gauges from flow cups and dip cups to rotational and cone and plate viscometers. Flow Cups: The process of flow through an orifice can often be used as a relative measurement and classification of viscosity. This measured kinematic viscosity is generally expressed in seconds of flow time which can be converted into Centistokes using a viscosity disc calculator. Dip Cups: Using the same principle as flow cups, dip cups Frikmar, Zahn, Shell, etc. can be used to provide a quick viscosity measurement on the shop floor or on site. Rotational: Rotational viscometers are used to determine the viscosity of liquids which do not depend solely on temperature and pressure. The behaviour of non-newtonian liquids can be determined using a range of rotational viscometers in particular the Cone and Plate viscometers (see pages 14-17). Flow & Dip Cups Viscosity Cup Reference Table 1 Cup Type Range (cst) Time (seconds) Minimum Maximum Minimum Maximum Advised Kinematic** Drain Time** Standard Oil Viscosity (cst) (seconds) DIN S ISO S ISO N ISO N ISO S ASTM N10 or C10* ASTM S20 or C20* ASTM S60 or C60* ASTM S60 or C60* ASTM S200 or C200* ZAHN N10 or C10* ZAHN S60 or C60* ZAHN S200 or C200* ZAHN S200 or C200* ZAHN N350 or C350* AFNOR 2.5 5Cps 140Cps S *** AFNOR 4 50Cps 1100Cps S *** AFNOR 6 510Cps 5100Cps S *** * The S and N prefix you have dynamic viscosity, kinematic viscosity and density at different temperatures; with the C prefix, kinematic viscosity and drain time is at 25ºC (77ºF) for Zahn, Ford and Shell Cups. ** Kinematic viscosity and drain times mentioned above are approximate values at 25ºC (77ºF). Exact values will be displayed on the standard oil bottle. *** For comparison only. 1 For information purposes only. 5

2 Viscosity Elcometer 2400 Viscosity Disc A conversion table that allows the viscosity (in cst) and flow times of different cups to be compared. Front: No. 4 Cups according to BS, NF, ASTM, DIN and Zahn 2. Back: No Cups according to ISO and Zahn 3, as well as Gardner Bubble Viscometers. Elcometer 2400 Elcometer 2400 Viscosity Conversion Disc KT002400N003 Elcometer 7300 Digital Stopwatch A professional high precision, Digital LCD pocket sized stopwatch for measuring flow time. Features include: Time/calendar display: hour, minute, second, month, day, date. Stopwatch: 1 /100 second for 30 minutes, 1 second up to 24 hours. 12/24 hour display mode. Elcometer 7300 Digital Stopwatch K M201 Accessories Replacement Battery (LR44) T How to use a Viscosity Cup Once the viscosity cup is truely horizontal (this is best achieved using a cup stand and bubble level), cover the exit orifice and fill the cup making sure that the meniscus of the liquid is above the rim of the cup. Using the glass draw plate, remove the meniscus into the overflow ring and close the cup. Open the exit orifice and remove the glass draw plate. Time between the removal of the glass draw plate and the first break in the liquid s flow is measured. Wet Film Applicators see pages

3 Viscosity Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO) Very easy to use instruments of anodized aluminium with a stainless steel orifice, for measuring the consistency of paints, varnishes and similar products. The measured kinematic viscosity is generally expressed in seconds (s) flow time. If the standards stipulate conversion methods the flow time can be converted in centistokes (cst) and, a calibration certificate is available upon request. The cups can be supplied separately or with an adjustable stand which includes a precision level and an overflow glass draw plate. The stand can also be supplied with a flow jacket for temperature control (thermo jacket). Several ranges are available, according to standards; from 5 to 5100cSt. Cup Number Viscosity Cup Type Range Centistokes (cst) 1 Elcometer 2350/1 2 DIN - K M001 Elcometer 2350/2 4 DIN K M002 Elcometer 2350/3 6 DIN DIN K M003 Elcometer 2350/4 8 DIN - K M004 Elcometer 2351/1 1 FORD ASTM K M001 Elcometer 2351/2 2 FORD ASTM K M002 Elcometer 2351/3 3 FORD ASTM FORD ASTM D K M003 Elcometer 2351/4 4 FORD ASTM K M004 Elcometer 2351/5 5 FORD ASTM K M005 Elcometer 2352/1 2.5 AFNOR NFT K M001 Elcometer 2352/2 4 AFNOR NFT AFNOR NFT K M002 Elcometer 2352/3 6 AFNOR NFT K M003 Elcometer 2353/1 3 ISO DIN NF NBN ASTM ISO K M001 Elcometer 2353/2 4 ISO DIN NF NBN ASTM DIN K M002 Elcometer 2353/3 5 ISO DIN NF NBN ASTM NFT NF EN K M003 Elcometer 2353/4 6 ISO DIN NF NBN ASTM ASTM D K M004 Elcometer 2353/5 8 ISO DIN NF NBN ASTM NBN T K M005 Elcometer 2354/1 2 BS - K M001 Elcometer 2354/2 3 BS - K M002 Elcometer 2354/3 4 BS BS 3900 A6 - K M003 Elcometer 2354/4 5 BS - K M004 Elcometer 2354/5 6 BS - K M005 Accessories Stand with Bubble Level for Cup and Glass Draw Plate KT002400N001 Double-walled Stand with Thermojacket (but without thermobath) KT002400N Viscosity Conversion Disc (see page 6) KT002400N003 Bubble Level for Viscosity Cup KT002400P001 Viscosity Glass Draw Plate KT002400P999 Stopwatches (see page 6) Viscosity Standard Oils for Calibration (see page 10) Elcometer provides a viscosity recalibration service using state of the art climate controlled facilities, for information please contact Elcometer. 1 for information only Viscosity Standard Oils see page 10 7

4 Viscosity Elcometer FRIKMAR Viscosity Cups with Handle Thanks to its handle, this cup is very easy to use and performs quick controls in the workshop or during the manufacturing process. Ideal for measuring the consistency of paints, varnishes and similar products. The cup is first dipped into the product to be measured, then empties through the orifice. The measured kinematic viscosity is generally expressed in seconds (s) flow time, which can be converted to Centistokes (cst), if standard stipulates conversion method. Several ranges are available, according to standards; from 7 to 1100cSt. Cup Number Viscosity Cup Type Range Centistokes (cst) 1 Elcometer 2434/1 2 DIN - K M001 Elcometer 2434/2 4 DIN K M002 DIN Elcometer 2434/3 6 DIN - K M003 Elcometer 2434/4 8 DIN - K M004 Elcometer 2435/1 4 ASTM ASTM D K M001 Elcometer 2436/1 4 AFNOR NTT AFNOR NTT K M001 Elcometer 2437/1 2 ISO DIN NF NBN ASTM - K M001 ISO 2431 Elcometer 2437/2 3 ISO DIN NF NBN ASTM 7-42 K M002 DIN Elcometer 2437/3 4 ISO DIN NF NBN ASTM NFT K M003 Elcometer 2437/6 5 ISO DIN NF NBN ASTM NF EN K M006 Elcometer 2437/4 6 ISO DIN NF NBN ASTM ASTM D 1525 NBNT K M004 Elcometer 2437/5 8 ISO DIN NF NBN ASTM - K M005 Accessories 2400 Viscosity Conversion Disc (see page 6) KT002400N003 Stopwatches (see page 6) Viscosity Standard Oils for Calibration (see page 10) Elcometer provides a viscosity recalibration service using state of the art, climate controlled facilities, for information please contact Elcometer. Elcometer 2210 Zahn Viscosity Cups Easy-to-use stainless steel apparatus, for quick viscosity measurement of products on site or during production. The cup is first dipped into the product to be measured, then empties through the orifice. The measured kinematic viscosity is generally expressed in seconds (s) flow time, which can be converted to Centistokes (cst). Five different orifices for measurements between 5 and 1840cSt are available. Cup Number Range Centistokes (cst) 1 Elcometer 2210/ K M001 Elcometer 2210/ K M002 Elcometer 2210/ K M003 Elcometer 2210/ K M004 Elcometer 2210/ K M005 Accessories 2400 Viscosity Conversion Disc (see page 6) KT002400N003 Stopwatches (see page 6) Viscosity Standard Oils for Calibration (see page 10) ASTM D 1084 ASTM D 4212 ASTM D 3794 Elcometer provides a viscosity recalibration service using state of the art, climate controlled facilities, for information please contact Elcometer. 1 for information only 8

5 Viscosity Elcometer 2310 Shell Viscosity Cups A stainless steel cup for quick measurements on-site or during production. This cup is often used in the printing or ink industry. The cup is first dipped into the product to be measured, then empties through the orifice. The measured kinematic viscosity is generally expressed in seconds (s) flow time, which can be converted to Centistokes (cst). Six different ranges are available for measurements between 2 and 1300cSt. ASTM D 4212 Cup Number Range Centistokes (cst) 1 Elcometer 2310/ K M001 Elcometer 2310/ K M002 Elcometer 2310/ K M003 Elcometer 2310/ K M004 Elcometer 2310/ K M005 Elcometer 2310/ K M006 Accessories 2400 Viscosity Conversion Disc (see page 6) KT002400N003 Stopwatches (see page 6) Viscosity Standard Oils for Calibration (see page 10) Elcometer provides a viscosity recalibration service using state of the art, climate controlled facilities, for information please contact Elcometer. Elcometer 2215 Lory LCH Cup Conventional cylindrical cup with a needle fixed into the bottom for quick measurements on-site or during production. The cup is first dipped into the product to be measured, then emptied. The flow time elapses when the point of the needle appears. Cup Number Range Centistokes (cst) 1 Elcometer 2215/ K M001 Accessories Stopwatches (see page 6) Elcometer provides a viscosity recalibration service using state of the art, climate controlled facilities, for information please contact Elcometer. 1 for information only Density/Specific Gravity Cups see page 18 9

6 Viscosity Elcometer 2410 Viscosity Standard Oils for Calibration In order to check your viscosity cup s calibration or to certify it for ISO purposes, it is imperative that you use viscosity standards. Standard oils have a specific drain time, dependent on the viscosity cup type (Ford, Shell, Zahn, etc), and the orifice or cup number used. To check the viscosity cup, simply use the standard viscosity oils in place of your liquid and measure the drain time. ( 1 /2 Litre/1 Pint). Elcometer 2410/1 Canon Standard Viscosity Oil S20-31 CPS at 25 C K M001 Elcometer 2410/2 Canon Standard Viscosity Oil S CPS at 25 C K M002 Elcometer 2410/3 Canon Standard Viscosity Oil S CPS at 25 C K M003 Elcometer 2410/4 Canon Standard Viscosity Oil S CPS at 25 C K M004 Elcometer 2410/11 Canon Standard Viscosity Oil N10-15 CPS at 25 C K M011 Elcometer 2410/12 Canon Standard Viscosity Oil N CPS at 25 C K M012 Elcometer 2410/13 Canon Standard Viscosity Oil N CPS at 25 C K M013 Elcometer 2410/21 Canon Standard Viscosity Oil C20-34 CPS at 25 C K M021 Elcometer 2410/22 Canon Standard Viscosity Oil C CPS at 25 C K M022 Elcometer 2410/23 Canon Standard Viscosity Oil C CPS at 25 C K M023 Elcometer 2410/24 Canon Standard Viscosity Oil C CPS at 25 C K M024 Elcometer 2410/25 Canon Standard Viscosity Oil C CPS at 25 C K M025 Elcometer 2410/26 Canon Standard Viscosity Oil C CPS at 25 C K M026 Elcometer provides a viscosity recalibration service using state of the art, climate controlled facilities, for information please contact Elcometer. Elcometer 4260 NYPC Levelling Tester Made of stainless steel with straight scraper fitted with 5 pairs of notches of increasing depth from 25µm to 4.06mm (1 to 160mils), the Elcometer 4260 NYPC Levelling Tester is used to determine a coating s ability to level before curing. Once the drawdown has been made on a horizontal, firm surface, leave the coating to cure. Once the coating is dry, identify the thickness at which the pair of film stripes merge. ASTM D 2801 Metric Imperial Elcometer 4260/1 Elcometer 4260 NYPC Levelling Tester K M201 K0US4260M201 Accessories Test Charts (see pages 33-38) Test Charts see pages

7 Viscosity Elcometer 4270 Sag Tester Made of stainless steel, the straight scraper has 10 adjacent notches of increasing clearance. The Elcometer 4270 Sag Tester is used to establish the coatings resistance to sag due to gravity. After the product has been spread, the contrast chart is immediately placed in a vertical position with the thinnest film at the top. The thickness at which the stripes join indicates the tendency to sag. FMTS 141A Method 4494 Range µm mils Metric Imperial Elcometer 4270/ Sag Tester K M001 K0US4270M001 Elcometer 4270/ Sag Tester K M002 K0US4270M002 Elcometer 4270/ Sag Tester K M203 K0US4270M203 Elcometer 4270/ Sag Tester K M204 K0US4270M204 Accessories Test Charts (see pages 33-38) Elcometer 4280 NYPC Levelling & Sag Tester The Elcometer 4280 combines the Elcometer 4260 NYPC Levelling Test with the Sag Test of the Elcometer This dual gauge is used to assess a coating s levelling characteristics and its resistance to sag due to gravity. ASTM D 2801 FMTS 141A Method 4494 Range µm mils Metric Imperial Elcometer 4280 Elcometer 4280 NYPC Levelling and Sag Tester K M001 K0US4280M001 Accessories Test Charts (see pages 33-38) Elcometer 4290 Sag Quadruplex Film Applicator This stainless steel film applicator has 4 spreading edges in the form of a straight scraper each with 4, 6 or 10 adjacent notches (depending on the model) of variable depth. Simultaneously applying several stripes of film of increasing thickness. Ideal for the determination of opacity or hiding power. ASTM D 2801 FMTS 141A Method 4494 Number of Apertures Between Apertures µm mils Metric Imperial Elcometer 4290/ Sag Quadruplex Applicator K M001 K0US4290M001 Elcometer 4290/ Sag Quadruplex Applicator K M003 K0US4290M003 Elcometer 4290/ Sag Quadruplex Applicator K M002 K0US4290M002 Accessories Test Charts for our complete range (see pages 33-38) 11

8 Viscosity Elcometer 2280 Matthis Fluidometer A simple and easy-to-use instrument to measure the fluidity of a coating. The product to be measured is poured into a semi-spherical cavity of the instrument, which is in the horizontal position. The instrument is then lifted vertically allowing the liquid to flow under gravity, in the groove, which is graduated in mm. The distance it flows after approximately 10 seconds ±0.5 seconds, measured with the sand timer provided, indicates the fluidity of the coating. Elcometer 2280/1 Matthis Fluidometer K M001 Accessories Spare Sand Bottle KT002280N001 Elcometer 2290 Daniel Flow Gauge This simple instrument is used to assess the ability of thick or paste-like materials such as paints or printing inks to flow. The product is poured into the semi-cylindrical reservoir. When the instrument is lifted vertically, the product runs on a graduated plate, which is fixed perpendicular to the reservoir. The distance covered in a given time is the measure of the fluidity. Elcometer 2290/1 Daniel Flow Gauge K M001 Test Charts see pages

9 Rotational Viscosity Rotational Viscosity Viscosity A measure of the resistance of a liquid to flow. Thixotropic Describes materials that are gel-like at rest but liquid when agitated. Centipoise A unit of measurement of which water is the standard at 1cP. Newtonian Liquids The viscosity of a Newtonian liquid is dependent only on temperature, not on shear rate and time. Non-Newtonian liquids - time dependent. The viscosity of the liquid is dependent on temperature, shear rate and time. Depending on how viscosity changes with time the flow behaviour is characterised as: Thixotropic (time thinning, i.e. viscosity decreases with time). Rheopetic (time thickening, i.e. viscosity increases with time). Thixotropic liquids are quite common in the chemical and food industries. Rheopectic liquids are very rare. Note: some liquids show time thinning behaviour due to breakdown of structure. This phenomenon is sometimes known as Rheomaiaxis. Non-Newtonian liquids - time independent. The viscosity of a Non-Newtonian time independent liquid is dependent not only on temperature but also on shear rate. Depending on how viscosity changes with shear rate, the flow behaviour is characterised as: shear thinning also known as Pseudoplastics - the viscosity decreases with increased shear rate. shear thickening also known as Dilatant - the viscosity increases with increased shear rate. plastic - exhibits a so-called yield value, i.e. a certain shear stress must be applied before flow occurs. Elcometer 2200 Digital Viscometer This simple to use rotational viscometer consists of a spindle and paddle. The spindle is rotated at 200rpm and, when the paddle is immersed in the sample coating, the Elcometer 2200 automatically calculates the viscosity value from the power required to maintain the spindle at 200rpm. A Choice of Three Viscosity Ranges. A digital display, at a flick of a switch, shows the reading selected in either: Centipoises Krebs Units Grams The Elcometer 2200 can also be fitted with an air purge for use in a hazardous environment. ASTM D 562 ASTM D 856 ASTM D 1131 FTMS 141 M 4281 Range Centipoise: 150 to 4000cP Krebs Units: 40 to 140KU KU Weight: 35 to 1150g Resolution Centipoise: 1.0cP Krebs Units: 0.1KU Weight: 1.0g Accuracy ± 1.0% of full scale Spindle Rotation Speed 200rpm ±0.2rpm UK 240V EUR 220V US 110V Elcometer 2200/1 Elcometer 2200 Digital Viscometer K0UK2200M202 K M202 K0US2200M202 Elcometer 2200/2 Elcometer 2200 Digital Viscometer with air purge K0UK2200M203 K M203 K0US2200M203 13

10 Rotational Viscosity Elcometer 2205 Analogue Cone & Plate Viscometer The Elcometer 2205 Cone and Plate Viscometer has been designed specifically to provide high shear rate tests for coatings. Running at a single speed of 900rpm (60Hz) or 750rpm (50Hz), the Elcometer 2205 Analogue Cone and Plate Viscometer comes in two model variations: Low Temperature s - Choose from either a range of single pre-set temperature models or a single model with three pre-set temperatures. High Temperature s - Supplied in 3 temperature ranges with 6 pre-set temperatures. The low temperature Viscometer: Designed to facilitate routine measurement of the viscosity of paints. Good correlation with application methods (e.g. brushing) is ensured by the use of a high rate of shear (10,000 sec -1 ). The cone and plate principle is selected because this is one of the most convenient ways of obtaining high rates of shear. The ranges of measurement of 0-2, 0-5poise and 0-10poise are chosen as suitable for most normal paints. Alternative rates of shear or ranges of measurement can be obtained by using cones of alternative size or angle see page 17 for the range of cone types available. BS 3900 A7 ASTM D 2196 Temperature control is essential in measuring the viscosity of paint. This Viscometer has a built-in provision for holding the sample at the temperature regardless of normal variations in the bulk sample or in room temperature. Heating or cooling of the sample is by a Peltier effect semi-conductor device. The sample reaches the control temperature in no more than 15 seconds. The high temperature Viscometer: Designed for the control of the viscosity of resins, bitumen, hot melts and similar products, during manufacture. These Viscometers enable a very small sample from the cooking vessel to be checked for viscosity in less than a minute. The instrument is thermostatically controlled over a wide range of temperatures, one of which is selected so that the melt viscosity of the resin comes within the viscosity range of the instrument. In this way, thinning tests are eliminated and a quick and accurate determination of resin viscosity is obtained. Ease of cleaning is ensured by the small sample required and the ease of access made possible by the simple geometry of the cone and plate principle. A wipe with paper tissue and suitable solvent is all that is normally required. Standard Viscosity Range 0-10poise at 10,000sec 0-2poise at 10,000sec poise at 2,500sec 0-2.5poise at 10,000sec poise at 2,500sec 0-5poise at 10,000sec poise at 2,500sec -1 Cone Type To suit range: 0-2, 0-5, 0-10, 0-20, 0-40, 0-100poise Accuracy ±2% of full scale, confirmed using oils traceable to National Standards Temperature control of sample One or three switched temperatures in the range 10-75ºC, (50-167ºF) Six temperatures in the range ºC, (77-446ºF) Variable temperature resolution ±0.1ºC (±0.2ºF) Temperature Type Range UK 240V EUR 220V US 110V Elcometer 2205/1 Analogue Cone & Plate Viscometer 1 20ºC (68ºF) K0UK2205M001 K M001 K0US2205M001 Elcometer 2205/2 Analogue Cone & Plate Viscometer 1 23ºC (73.4ºF) K0UK2205M002 K M002 K0US2205M002 Elcometer 2205/3 Analogue Cone & Plate Viscometer 1 25ºC (77ºF) K0UK2205M003 K M003 K0US2205M003 Elcometer 2205/4 Analogue Cone & Plate Viscometer 1 30ºC (86ºF) K0UK2205M004 K M004 K0US2205M004 Elcometer 2205/10 Analogue Cone & Plate Viscometer ºC (50-167ºF) K0UK2205M010 K M010 K0US2205M010 Elcometer 2205/21 Analogue Cone & Plate Viscometer ºC (77-302ºF) K0UK2205M021 K M021 K0US2205M021 Elcometer 2205/22 Analogue Cone & Plate Viscometer ºC (77-392ºF) K0UK2205M022 K M022 K0US2205M022 Elcometer 2205/23 Analogue Cone & Plate Viscometer ºC (77-446ºF) K0UK2205M023 K M023 K0US2205M023 Please select the cone type required for your coatings application from the Cone List on page

11 Rotational Viscosity Elcometer 2206 Digital Cone & Plate Viscometer The Elcometer 2206 is a Cone and Plate Viscometer designed for quick results, required by Process Control and Quality Departments when monitoring production. Although manufactured in a rugged design needed for manufacturing, the Elcometer 2206 has a range of features to meet the ever demanding controls on modern production standards. A range of low and high temperature models are available to meet your exact requirement. Choose either a single temperature, 3 or 6 pre-set temperatures or set your own temperature using our variable temperature model. Used in the paint, varnish, inks, resins, food, bitumen, oil, adhesives and pharmaceutical industries. The low temperature Viscometer: Designed to facilitate routine measurement of the viscosity of paints. Good correlation with application methods (e.g. brushing) is ensured by the use of a high rate of shear (10,000 sec -1 ). The cone and plate principle is selected because this is one of the most convenient ways of obtaining high rates of shear. ASTM D 4287 BS 3900 A7 The ranges of measurement of 0-2, 0-5poise and 0-10poise are chosen as suitable for ISO 2884 most normal paints. Alternative rates of shear or ranges of measurement can be obtained by using cones of alternative size or angle. Temperature control is essential in measuring the viscosity of paint. This Viscometer has built-in provision for holding the sample at the temperature regardless of normal variations in the bulk sample or in room temperature. Heating or cooling of the sample is by a Peltier effect semi-conductor device. The sample reaches the control temperature in no more than 15 seconds. The high temperature Viscometer: Designed for the control of the viscosity of resins, bitumen, hot melts and similar products, during manufacture. These Viscometers enable a very small sample from the cooking vessel to be checked for viscosity in less than a minute. The instrument is thermostatically controlled over a wide range of temperatures, one of which is selected so that the melt viscosity of the resin comes within the viscosity range of the instrument. In this way, thinning tests are eliminated and a quick and accurate determination of resin viscosity is obtained. Ease of cleaning is ensured by the small sample required and the ease of access made possible by the simple geometry of the cone and plate principle. A wipe with paper tissue and suitable solvent is all that is normally required. Standard Viscosity Range 0-10poise at 10,000sec 0-2poise at 10,000sec poise at 2,500sec 0-2.5poise at 10,000sec poise at 2,500sec 0-5poise at 10,000sec poise at 2,500sec -1 Cone Type To suit range: 0-2, 0-5, 0-10, 0-20, 0-40, 0-100poise Accuracy ±2% of full scale, confirmed using oils traceable to National Standards. Temperature control of sample One or three switched temperatures in the range 10-75ºC, (50-167ºF) Six temperatures in the range ºC, (77-446ºF) Variable Temperature Setting 10-75ºC or ºC (50-167ºF or ºF) Variable temperature resolution ±0.1ºC (±0.2ºF) Temperature Type Range UK 240V EUR 220V US 110V Elcometer 2206/1 Digital Cone and Plate Viscometer 1 20ºC (68ºF) K0UK2206M001 K M001 K0US2206M001 Elcometer 2206/2 Digital Cone and Plate Viscometer 1 23ºC (73.4ºF) K0UK2206M002 K M002 K0US2206M002 Elcometer 2206/3 Digital Cone and Plate Viscometer 1 25ºC (77ºF) K0UK2206M003 K M003 K0US2206M003 Elcometer 2206/4 Digital Cone and Plate Viscometer 1 30ºC (86ºF) K0UK2206M004 K M004 K0US2206M004 Elcometer 2206/10 Digital Cone and Plate Viscometer ºC (50-167ºF) K0UK2206M010 K M010 K0US2206M010 Elcometer 2206/21 Digital Cone and Plate Viscometer ºC (77-302ºF) K0UK2206M021 K M021 K0US2206M021 Elcometer 2206/22 Digital Cone and Plate Viscometer ºC (77-392ºF) K0UK2206M022 K M022 K0US2206M022 Elcometer 2206/23 Digital Cone and Plate Viscometer ºC (77-446ºF) K0UK2206M023 K M023 K0US2206M023 Elcometer 2206/30 Digital Cone and Plate Viscometer variable 10-75ºC (50-167ºF) K0UK2206M030 K M030 K0US2206M030 Elcometer 2206/31 Digital Cone and Plate Viscometer variable ºC (77-446ºF) K0UK2206M031 K M031 K0US2206M031 Please select the cone type required for your coatings application from the Cone List on page

12 Rotational Viscosity Elcometer 2207 Multi-Speed Digital Cone & Plate Viscometer The Elcometer 2207 Cone and Plate Viscometer allows the User to not only select the appropriate temperature range (between 10º and 230ºC, [50º 446ºF]), but also take readings at variable shear rates using the Elcometer 2207 s multiple speed control. The User has the option of either a three speed model or an 8 speed model for even greater choice. See page 17 for a list of the range of viscosity values at each of the different speeds. Select from a range of different temperature options single temperature, 3 or 6 pre-set temperatures or user definable temperatures. Only a small sample is required very easy to clean. The Elcometer 2207 provides an accurate result in seconds. Wide temperature range pre-set or user variable. Thermostatic control. Latched button. ASTM D 4287 BS 3900 A7 Auto zero. ISO 2884 Recalibration by a simple lever adjustment. Digital display indicates: Operating Range and Reading value in poise (P). Full Scale Poise Ranges: 2, 5, 10, 20, 40, 100poise at 750rpm; 62.5, 125, 250, 500poise at 60rpm. Standard Viscosity Range See Multi-Speed Range Table on page 17 Accuracy ±2% of full scale, confirmed using oils traceable to National Standards. Temperature control of sample One or three switched temperatures in the range 10-75ºC, (50-167ºF) Six temperatures in the range ºC, (77-446ºF) Variable Temperature Setting 10-75ºC or ºC, (50-167ºF or ºF) Variable temperature resolution ±0.1ºC (±0.2ºF) Cone Type Please select the cone type required for your coatings application from the Cone List on page 17. Temperature Type Range UK 240V EUR 220V US 110V Elcometer 2207/1 Multi-Speed Cone & Plate 1 temp, 3 speeds 20ºC (68ºF) K0UK2207M001 K M001 K0US2207M001 Elcometer 2207/2 Multi-Speed Cone & Plate 1 temp, 3 speeds 23ºC (73.4ºF) K0UK2207M002 K M002 K0US2207M002 Elcometer 2207/3 Multi-Speed Cone & Plate 1 temp, 3 speeds 25ºC (77ºF) K0UK2207M003 K M003 K0US2207M003 Elcometer 2207/4 Multi-Speed Cone & Plate 1 temp, 3 speeds 30ºC (86ºF) K0UK2207M004 K M004 K0US2207M004 Elcometer 2207/10 Multi-Speed Cone & Plate 3 temp, 3 speeds 10-75ºC (50-167ºF) K0UK2207M010 K M010 K0US2207M010 Elcometer 2207/21 Multi-Speed Cone & Plate 6 temp, 3 speeds ºC (77-302ºF) K0UK2207M021 K M021 K0US2207M021 Elcometer 2207/22 Multi-Speed Cone & Plate 6 temp, 3 speeds ºC (77-392ºF) K0UK2207M022 K M022 K0US2207M022 Elcometer 2207/23 Multi-Speed Cone & Plate 6 temp, 3 speeds ºC (77-446ºF) K0UK2207M023 K M023 K0US2207M023 Elcometer 2207/30 Multi-Speed Cone & Plate variable, 3 speeds 10-75ºC (50-167ºF) K0UK2207M030 K M030 K0US2207M030 Elcometer 2207/31 Multi-Speed Cone & Plate variable, 3 speeds ºC (77-446ºF) K0UK2207M031 K M031 K0US2207M031 Elcometer 2207/41 Multi-Speed Cone & Plate 1 temp, 8 speeds 20ºC (68ºF) K0UK2207M041 K M041 K0US2207M041 Elcometer 2207/42 Multi-Speed Cone & Plate 1 temp, 8 speeds 23ºC (73.4ºF) K0UK2207M042 K M042 K0US2207M042 Elcometer 2207/43 Multi-Speed Cone & Plate 1 temp, 8 speeds 25ºC (77ºF) K0UK2207M043 K M043 K0US2207M043 Elcometer 2207/44 Multi-Speed Cone & Plate 1 temp, 8 speeds 30ºC (86ºF) K0UK2207M044 K M044 K0US2207M044 Elcometer 2207/50 Multi-Speed Cone & Plate 3 temp, 8 speeds 10-75ºC (50-167ºF) K0UK2207M050 K M050 K0US2207M050 Elcometer 2207/51 Multi-Speed Cone & Plate 6 temp, 8 speeds ºC (77-302ºF) K0UK2207M051 K M051 K0US2207M051 Elcometer 2207/52 Multi-Speed Cone & Plate 6 temp, 8 speeds ºC (77-392ºF) K0UK2207M052 K M052 K0US2207M052 Elcometer 2207/53 Multi-Speed Cone & Plate 6 temp, 8 speeds ºC (77-446ºF) K0UK2207M053 K M053 K0US2207M053 Elcometer 2207/60 Multi-Speed Cone & Plate variable, 8 speeds 10-75ºC (50-167ºF) K0UK2207M060 K M060 K0US2207M060 Elcometer 2207/61 Multi-Speed Cone & Plate variable, 8 speeds ºC (77-446ºF) K0UK2207M061 K M061 K0US2207M061 Please select the cone type required for your coatings application from the Cone List on page

13 Rotational Viscosity CONE TYPES FOR ALL ELCOMETER CONE AND PLATE VISCOMETERS Standard Viscosity Range Cone Type Poise Shear Rate 2P 0-2 to 0-256poise 80-10,000 sec -1 KT002205N001 5P 0-5 to 0-640poise 80-10,000sec -1 KT002205N002 10P 0-10 to poise 80-10,000sec -1 KT002205N003 20P 0-20 to poise 20-2,500sec -1 KT002205N004 40P 0-40 to poise 20-2,500sec -1 KT002205N P to poise 20-2,500sec -1 KT002205N006 ELCOMETER 2207 MULTI-SPEED CONE AND PLATE VISCOMETER RANGE TABLE Speed Range (Poise, P) Setting rpm 5P Cone 10P Cone 20P Cone 40P Cone 100P Cone ELCOMETER 2207 MULTI-SPEED CONE AND PLATE VISCOMETER CONVERSION FACTORS; RANGE SET AT 10.0P Multiply the reading obtained on the Elcometer 2207 by the relevant factor below to obtain the Poise Reading Speed Shear Factor Shear Factor Setting Rate 5P Cone 10P Cone Rate 20P Cone 40P Cone 100P Cone Computer Software is also available please contact Elcometer for further information. 17

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO)

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO) At a glance Anodized aluminium with a stainless steel orifice. For measuring the consistency of paints Expressed in second (s) flow time. Can be converted into centistokes. Available with adjustable stand.

More information

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO)

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO) At a glance Anodized aluminium with a stainless steel orifice. For measuring the consistency of paints Expressed in second (s) flow time. Can be converted into centistokes. Available with adjustable stand.

More information

Viscosity - Flow Cups. elcometer.com

Viscosity - Flow Cups. elcometer.com elcometer.com Viscosity - Flow Cups 1 Viscosity - Flow Cups Elcometer 2350 & 2354 Viscosity Flow Cups Viscosity Flow Cups are very easy to use instruments made of anodized aluminium with a stainless steel

More information

Introduction VISCOSITY. Appearance Color Physical Properties Viscosity Technical Service Index

Introduction VISCOSITY. Appearance Color Physical Properties Viscosity Technical Service Index Introduction Viscosity is a measure of the resistance of a fluid to deform under shear stress. It is commonly perceived as flow behaviour or resistance to pouring. Viscosity describes a fluids internal

More information

Standard Test Methods for Viscosity of Adhesives 1

Standard Test Methods for Viscosity of Adhesives 1 Designation: D 1084 97 Standard Test Methods for Viscosity of Adhesives 1 This standard is issued under the fixed designation D 1084; the number immediately following the designation indicates the year

More information

Determination of Viscosity Using A Brookfield Viscometer for Conditioning Polymers

Determination of Viscosity Using A Brookfield Viscometer for Conditioning Polymers LUBRIZOL TEST PROCEDURE TP-N01004 Edition: December 2, 2013 Previous Editions: August 10, 2000 / November 1, 2011 Determination of Viscosity Using A Brookfield Scope A material's flow property is an important

More information

This document establishes MSHA s Standard Test Procedure (STP) for the Determining the Viscosity of a Hydraulic Fluid in Saybolt Universal Seconds.

This document establishes MSHA s Standard Test Procedure (STP) for the Determining the Viscosity of a Hydraulic Fluid in Saybolt Universal Seconds. DOCUMENT NO: ASTP 5005 VERSION: 2010-02-12 Page 1 of 9 1.0 PURPOSE This document establishes MSHA s Standard Test Procedure (STP) for the Determining the Viscosity of a Hydraulic Fluid in Saybolt Universal

More information

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT CHAPTER 2: LIQUID VISCOSITY MEASUREMENT Objective Calculate viscosity (dynamic or absolute, and kinematic) and determine how this property varies with changes in temperature for a constant-composition

More information

A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom

A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom The Civil Engineering Center 1 Visit www.ahm531.com for more lecture notes and E-book! The Civil Engineering Center 2 Visit www.ahm531.com for more lecture notes and E-book! Introduction : The grades of

More information

PUMPS STEAM TURBINES BUILDING & FIRE WASTEWATER SERVICE PUMP CLINIC 22 VISCOSITY

PUMPS STEAM TURBINES BUILDING & FIRE WASTEWATER SERVICE PUMP CLINIC 22 VISCOSITY PUMP CLINIC 22 VISCOSITY The viscosity of a fluid is that property which tends to resist a shearing force. It can be thought of as the internal friction resulting when one layer of fluid is made to move

More information

PHYSICS FUNDAMENTALS-Viscosity and flow

PHYSICS FUNDAMENTALS-Viscosity and flow PHYSICS FUNDAMENTALS-Viscosity and flow The origin of viscosity When a force is applied to a solid, it will yield slightly, and then resist further movement. However, when we apply force to a fluid, it

More information

PENETRATION OF BITUMINOUS MATERIALS

PENETRATION OF BITUMINOUS MATERIALS NANYANG TECHNOLOGICAL UNIVERSITY School of Civil and Structural Engineering LABORATORY - PAVEMENT MATERIALS PENETRATION OF BITUMINOUS MATERIALS OBJECTIVES To examine the consistency of a sample of bitumen

More information

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure. Recommend Approval: Team Leader Date Division Chief Date Approved: Director Date Maryland Department of Transportation State Highway Administration Office of Materials Technology MARYLAND STANDARD METHOD

More information

User's Guide. Digital Viscotesters. Model 345060 High Range (0.3 to 4000 dpas) Model 345055 Low Range (1.5 to 330 mpas) Introduction

User's Guide. Digital Viscotesters. Model 345060 High Range (0.3 to 4000 dpas) Model 345055 Low Range (1.5 to 330 mpas) Introduction User's Guide Digital Viscotesters Model 345060 High Range (0.3 to 4000 dpas) Model 345055 Low Range (1.5 to 330 mpas) Introduction Congratulations on your purchase of the Extech Digital Viscotester. The

More information

RHEOLOGY RHEOLOGY Science describing the flow and deformation of matter under stress. Rheo = the flow Viscosity (η) is the resistance of a fluid material to flow under stress. The higher the viscosity,

More information

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1 Designation: D562 01 (Reapproved 2005) Standard Test Method for Consistency of Paints Measuring Krebs Unit () Viscosity Using a Stormer-Type Viscometer 1 This standard is issued under the fixed designation

More information

Rheological Properties of Topical Formulations

Rheological Properties of Topical Formulations Rheological Properties of Topical Formulations Hemi Nae, PhD Hydan Technologies, Inc. Key Words Complex Modulus, Creep/Recovery, Dilatant Flow, Dynamic Viscosity, Flow, Flow Curve, Flow Models, Frequency

More information

Penetration. www.koehlerinstrument.com. www.koehlerinstrument.com. Test Methods

Penetration. www.koehlerinstrument.com. www.koehlerinstrument.com. Test Methods Test Methods Penetration of Bituminous Materials ASTM D5; IP 49; DIN 52010 Cone Penetration of Lubricating Grease ASTM D217; IP 50; ISO 2137; DIN 51804; FTM 791-311, FTM 791-313 Cone Penetration of Petrolatum

More information

GUIDELINES FOR TESTING FRESH SELF-COMPACTING CONCRETE

GUIDELINES FOR TESTING FRESH SELF-COMPACTING CONCRETE Growth Contract No. GRD2-2000-30024 GUIDELINES FOR TESTING FRESH SELF-COMPACTING CONCRETE Principal author: G. DE SCHUTTER September 2005 European Research Project: MEASUREMENT OF PROPERTIES OF FRESH SELF-COMPACTING

More information

Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability

Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability T h e r i g h t t e m p e r a t u r e w o r l d w i d e Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability

More information

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES Liquid Coating Properties Composition VOC Content, ASTM D2369 Water Content, ASTM D4017 Physical Properties Calculating Physical Constants of Coatings, ASTM D5201 Density, ASTM D1475 Flash Point, ASTM

More information

VISCOSITY OF A LIQUID. To determine the viscosity of a lubricating oil. Time permitting, the temperature variation of viscosity can also be studied.

VISCOSITY OF A LIQUID. To determine the viscosity of a lubricating oil. Time permitting, the temperature variation of viscosity can also be studied. VISCOSITY OF A LIQUID August 19, 004 OBJECTIVE: EQUIPMENT: To determine the viscosity of a lubricating oil. Time permitting, the temperature variation of viscosity can also be studied. Viscosity apparatus

More information

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical Thickness Gauges Technical Data for Metric Thickness Gauges Page Model Lifting Contact points Contact points mm mm mm device standard available on request 130 K 15 0.1 10 15 no 6.35 mm Ø flat Ø flat, 130

More information

Viscosity. Desmond Schipper Andrew R. Barron. 1 Introduction

Viscosity. Desmond Schipper Andrew R. Barron. 1 Introduction OpenStax-CNX module: m50215 1 Viscosity Desmond Schipper Andrew R. Barron This work is produced by OpenStax-CNX and licensed under the Creative Commons Attribution License 4.0 Abstract This module discusses

More information

Ultrasonic Reference Blocks

Ultrasonic Reference Blocks Ultrasonic Reference Blocks Custom and Standard Test Blocks for Nondestructive Testing Introduction 3 IIW Type 1 Calibration Block 4 Miniature Angle Beam (ROMPAS) Calibration Block 4 Distance Calibration

More information

Microwave Meter. Instruction Manual

Microwave Meter. Instruction Manual Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted

More information

Additional Information. Paint Application

Additional Information. Paint Application Additional Information Paint Prepared by: International Paint Ltd. www.international-pc.com The information in this guideline is not intended to be exhaustive; any person using the product for any purpose

More information

Standard Test Procedures Manual

Standard Test Procedures Manual STP 206-4 Standard Test Procedures Manual Section: 1. SCOPE 1.1. Description of Test This method describes the procedure for determining the liquid limit, plastic limit and the plasticity index of coarse-grained

More information

Paint Test Equipment. Stargloss Gloss Meter Data Sheet

Paint Test Equipment. Stargloss Gloss Meter Data Sheet Paint Test Equipment Stargloss Gloss Meter Data Sheet Coating Thickness Gloss Porosity Adhesion Surface Roughness Surface Cleanliness Climatic Conditions Electrostatic Inspectors Accessories Complies with

More information

Paint Test Equipment. Holitech DC Holiday Tester Data Sheet

Paint Test Equipment. Holitech DC Holiday Tester Data Sheet Paint Test Equipment Holitech DC Holiday Tester Data Sheet Coating Thickness Gloss Porosity Adhesion Surface Roughness Surface Cleanliness Climatic Conditions Electrostatic Inspectors Accessories Complies

More information

Penetration. www.koehlerinstrument.com. www.koehlerinstrument.com. www.labomat.eu. Test Methods

Penetration. www.koehlerinstrument.com. www.koehlerinstrument.com. www.labomat.eu. Test Methods Test Methods Penetration of Bituminous Materials ASTM D5; IP 49; DIN 52010 Cone Penetration of Lubricating Grease ASTM D217; IP 50; ISO 2137; DIN 51804; FTM 791-311, FTM 791-313 Cone Penetration of Petrolatum

More information

Notes on Polymer Rheology Outline

Notes on Polymer Rheology Outline 1 Why is rheology important? Examples of its importance Summary of important variables Description of the flow equations Flow regimes - laminar vs. turbulent - Reynolds number - definition of viscosity

More information

Ubbel. Viscometers and their range of use. Viscometer type. Cannon-Fenske reverse flow BS/IP-U tube reverse flow. Cannon-Fenske-Routine

Ubbel. Viscometers and their range of use. Viscometer type. Cannon-Fenske reverse flow BS/IP-U tube reverse flow. Cannon-Fenske-Routine Viscometers and their range of use Measurement substance property Viscometer type Ubbelohde Micro Ubbelohde TC Ubbelohde Ostwald Micro Ostwald Cannon-Fenske-Routine Cannon-Fenske reverse flow BS/IP-U tube

More information

globe reactions made easy Process perfection

globe reactions made easy Process perfection globe reactions made easy Process perfection Benefits More reactions in less time: The Globe oil drain unit and quick clamp allow single hand vessel changes in seconds Space saving: 50ml, 100ml, 250ml,

More information

TENSIONMETER ** code 183_LNRSTW **

TENSIONMETER ** code 183_LNRSTW ** Electronic tension meter for applications in textile and wire industry. 9 Tension ranges from 0.1-200 cn to 5-50 dan. Versatile instruments usable for applications in textile industry: e. g. 50 up to max.

More information

Calibration of Volumetric Glassware

Calibration of Volumetric Glassware Chemistry 119: Experiment 2 Calibration of Volumetric Glassware For making accurate measurements in analytical procedures, next in importance to the balance is volumetric equipment. In this section volumetric

More information

PRODUCT DATA SHEET DESCRIPTION:

PRODUCT DATA SHEET DESCRIPTION: DESCRIPTION: SP-9888 Pipe Lining is based on the latest Zero VOC Novolac Technology. The product cures to a highly cross-linked coating with excellent chemical, solvent and water immersion resistance.

More information

Operating Instructions. Manual No. M02-312-B0315

Operating Instructions. Manual No. M02-312-B0315 BROOKFIELD CAP 1000+ Viscometer MODEL CAP 1000+ Operating Instructions Manual No. M02-312-B0315 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY with offices in: Boston Chicago London Stuttgart

More information

1. Fluids Mechanics and Fluid Properties. 1.1 Objectives of this section. 1.2 Fluids

1. Fluids Mechanics and Fluid Properties. 1.1 Objectives of this section. 1.2 Fluids 1. Fluids Mechanics and Fluid Properties What is fluid mechanics? As its name suggests it is the branch of applied mechanics concerned with the statics and dynamics of fluids - both liquids and gases.

More information

Operating Instructions. Manual No. M02-312

Operating Instructions. Manual No. M02-312 BROOKFIELD CAP1000+ VISCOMETER MODEL CAP 1000+ Operating Instructions Manual No. M02-312 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY BROOKFIELD ENGINEERING LABORATORIES, INC. 11 Commerce Boulevard,

More information

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements DMS 680 Universal length measuring system gauge inspection for»iso 9000«requirements Universal length measuring system DMS 680 Wide range of applications For periodic inspection of gauges, reference gauges,

More information

TIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings.

TIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings. Product Data Sheet SERIES 69 - DRYZINC ZINC-RICH PRIMER (69/90500) Epoxy zinc-rich powder coating primer. Part of a two-coat TIGER Shield system. Designed to impart superior corrosion protection to steel

More information

3 Scotch-Seal TM. Tamper Proof Sealant 1252. Technical Data Issue No. 5

3 Scotch-Seal TM. Tamper Proof Sealant 1252. Technical Data Issue No. 5 3 Scotch-Seal TM Technical Data Issue No. 5 Advantages 3M Scotch-Seal is a one-part, fast drying, antitamper sealer. Self-extinguishing. It can be applied over adjustable or removable parts to indicate

More information

Hello viewers welcome to lesson 4.7 which is on pavement materials part IV and in this lesson we will be covering bituminous binders.

Hello viewers welcome to lesson 4.7 which is on pavement materials part IV and in this lesson we will be covering bituminous binders. Introduction to Transportation Engineering Prof. K. Sudhakar Reddy Department of Civil Engineering Indian Institute of Technology, Kharagpur Lecture - 30 Pavement Materials IV Hello viewers welcome to

More information

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, 2016. Product Description

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, 2016. Product Description 3 Scotch-Weld TM 1838 1838 1838-L Technical Data February, 2016 Description 3M TM Scotch-Weld TM s 1838 and are controlled flow products; Scotch-Weld 1838-L is flowable. These epoxy adhesives are two-part,

More information

Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers

Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers Magnetic Stirrers Patented RET control-visc with white coated heating plate! > Offers excellent chemical resistance > Easy to clean RET controlvisc kg Integrated temperature sensor for precise temperature

More information

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages

More information

Multiple flasks. Easy to adapt. Stuart range of heating blocks

Multiple flasks. Easy to adapt. Stuart range of heating blocks Heating Blocks The Stuart range of heating blocks have been developed in conjunction with DrySyn to provide the best possible solution for heating round bottom flasks. Combined with the Stuart range of

More information

Ti-Pure TITANIUM DIOXIDE. DETERMINATION OF BROOKFIELD VISCOSITY, TiO 2 SLURRY METHOD: T4400.535.01.WP

Ti-Pure TITANIUM DIOXIDE. DETERMINATION OF BROOKFIELD VISCOSITY, TiO 2 SLURRY METHOD: T4400.535.01.WP Ti-Pure TITANIUM DIOXIDE DETERMINATION OF BROOKFIELD VISCOSITY, TiO 2 SLURRY METHOD: T4400.535.01.WP 1 TITANIUM DIOXIDE (Ti-Pure ) Determination of Viscosity by Brookfield Viscometer I. Principle Viscosity

More information

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level

More information

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD 1 SCOPE The in-place dry density of compacted soil or gravel, as defined below, is determined

More information

Viscosity. www.koehlerinstrument.com. Test Methods

Viscosity. www.koehlerinstrument.com. Test Methods Viscosity Test Methods Page Kinematic Viscosity of Transparent and Opaque Liquids ASTM D445; IP 71; ISO 3104; DIN 51550; FTM 791-305...2-13 Kinematic Viscosity of Asphalts (Bitumens) ASTM D2170...2-13

More information

QUANTIFYING SOLAR ENERGY

QUANTIFYING SOLAR ENERGY www.sustainicum.at QUANTIFYING SOLAR ENERGY Recommendations for implementation in the course Author: E-Mail address: Institution: Philipp Weihs weihs@mail.boku.ac.at BOKU Important considerations Very

More information

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated Scotch-Weld TM Product Data Sheet DP410 Off-White Supersedes: October 2001 Product Description DP410 epoxy adhesive is a low flow, two-part epoxy based structural adhesive. It is designed for use where

More information

Operating Instructions, version 1.20. Manual No. M/94-310-F699

Operating Instructions, version 1.20. Manual No. M/94-310-F699 BROOKFIELD CAP VISCOMETERS MODELS CAP 1000 and CAP 2000 Operating Instructions, version 1.20 Manual No. M/94-310-F699 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY BROOKFIELD ENGINEERING LABORATORIES,

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

Calibration of Volumetric Glassware

Calibration of Volumetric Glassware CHEM 311L Quantitative Analysis Laboratory Revision 2.3 Calibration of Volumetric Glassware In this laboratory exercise, we will calibrate the three types of glassware typically used by an analytical chemist;

More information

Asphalt Institute Technical Bulletin. Laboratory Mixing and Compaction Temperatures

Asphalt Institute Technical Bulletin. Laboratory Mixing and Compaction Temperatures ASPHALT INSTITUTE EXECUTIVE OFFICES AND RESEARCH CENTER Research Park Drive P.O. Box 14052 Lexington, KY 40512-4052 USA Telephone 859-288-4960 FAX No. 859-288-4999 Asphalt Institute Technical Bulletin

More information

ICH Topic Q4B Annex 5 Disintegration Test General Chapter. Step 3

ICH Topic Q4B Annex 5 Disintegration Test General Chapter. Step 3 European Medicines Agency June 2008 EMEA/CHMP/ICH/308895/2008 ICH Topic Q4B Annex 5 Disintegration Test General Chapter Step 3 ANNEX 5 TO NOTE FOR EVALUATION AND RECOMMENDATION OF PHARMACOPOEIAL TEXTS

More information

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test

More information

Putting the Simple Back into Viscosity. Written by John Sander Vice President of Technology Lubrication Engineers, Inc.

Putting the Simple Back into Viscosity. Written by John Sander Vice President of Technology Lubrication Engineers, Inc. White Paper LE WHITE PAPER Written by John Sander Vice President of Technology Lubrication Engineers, Inc. The Lubrication Reliability Source www.le-inc.com 800-537-7683 1 Abstract: Simply stated, viscosity

More information

Catalase. ***You will be working with hot water, acids and bases in this laboratory*** ****Use Extreme Caution!!!****

Catalase. ***You will be working with hot water, acids and bases in this laboratory*** ****Use Extreme Caution!!!**** AP BIOLOGY BIOCHEMISTRY ACTIVITY #9 NAME DATE HOUR CATALASE LAB INTRODUCTION Hydrogen peroxide (H 2 O 2 ) is a poisonous byproduct of metabolism that can damage cells if it is not removed. Catalase is

More information

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used. STAGE MICROMETERS Introduction Whenever there is a need to make measurements with an eyepiece graticule, there is also a need to ensure that the microscope is calibrated. The use of a stage micrometer

More information

ArtisanLink Staining System is an automated special stains slide

ArtisanLink Staining System is an automated special stains slide Technical Tips Tips on using the ArtisanLink Special Staining System Jamie Nowacek, BS, HT(ASCP) CM, QIHC, PMP Dako North America, Inc. Carpinteria, CA, USA ArtisanLink Staining System is an automated

More information

Apr 17, 2000 LAB MANUAL 1811.0

Apr 17, 2000 LAB MANUAL 1811.0 Apr 17, 2000 LAB MANUAL 1811.0 1811 BULK SPECIFIC GRAVITY (GMB) AND DENSITY OF COMPACTED BITUMINOUS SPECIMENS USING PARAFFIN OR PARAFILM ASTM Designation D 1188 (MN/DOT Modified) 1811.1 SCOPE This test

More information

Clifton Food Range Bath Choice Booklet

Clifton Food Range Bath Choice Booklet Clifton Food Range Bath Choice Booklet Choosing the right equipment for you. - Nickel-Electro Ltd 2012. All rights reserved. Nickel-Electro Ltd., Oldmixon Crescent, Weston-s-Mare, North Somerset, BS24

More information

Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens) 1

Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens) 1 Designation: D 2170 95 Designation: 319/84 (89) Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens) 1 This standard is issued under the fixed designation D 2170; the number immediately

More information

Hygro-Thermometer + InfraRed Thermometer Model RH101

Hygro-Thermometer + InfraRed Thermometer Model RH101 User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative

More information

Soil Testing Soil index properties 24. Cone Penetrometer Method BS 1377, 1924-2, EN DD ENV 1997-2. Semi-Automatic Cone Penetrometer

Soil Testing Soil index properties 24. Cone Penetrometer Method BS 1377, 1924-2, EN DD ENV 1997-2. Semi-Automatic Cone Penetrometer 24 Soil index properties Soil Index Properties Soil index properties are used extensively by engineers to discriminate between the different kinds of soil within a broad category, e.g. clay will exhibit

More information

DENSITY MEASURING SYSTEMS

DENSITY MEASURING SYSTEMS SHIBAYAMA SCIENTIFIC CO., LTD. DENSITY MEASURING SYSTEMS Density Gradient Tube Method Direct Reading Type A / Type B Comply with the standards below: JIS K-0061-1992, K-7112 1980 ASTM D1505 Type A /Left

More information

PTFE Slide Bearings 04/10 149

PTFE Slide Bearings 04/10 149 04/10 149 1.0 GENERAL INFORMATION In a wide range of applications, PTFE Slide bearings are superior to conventional expansion plates, rollers and rocker arm type supports. They support petrochemical plant,

More information

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013 Scotch-Weld TM Product Data Sheet Acrylic Adhesives Date: Supersedes: August 2013 Product Description 3M TM Scotch-Weld Acrylic Adhesives are high performance, twopart acrylic adhesives that offer good

More information

S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS. Final text for addition to The International Pharmacopoeia

S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS. Final text for addition to The International Pharmacopoeia March 2012 S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS Final text for addition to The International Pharmacopoeia This monograph was adopted at the Forty-sixth WHO Expert Committee on Specifications

More information

Specifications For Manufactured Materials

Specifications For Manufactured Materials SMM 1301-1 Specifications For Manufactured Materials 1. SCOPE This specification covers the requirements for white and yellow fast dry alkyd traffic paint, suitable for airless and air atomized spray application

More information

PRODUCT DATA SHEET Sika Cable System

PRODUCT DATA SHEET Sika Cable System PRODUCT DATA SHEET Corrosion protection for bridge cables of steel and galvanized steel PRODUCT DESCRIPTION The Sika Cable System consists of coating materials as well as a sealing respectively injection

More information

VISCOSITY CLASSIFICATIONS

VISCOSITY CLASSIFICATIONS VISCOSITY CLASSIFICATIONS INDUSTRIAL LUBRICANT CASSIFICATIONS ISO (International Standards Organisation) viscosity classification The ISO viscosity classification uses mm 2 /s () units and relates to viscosity

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Scotch-Weld. Low-Odor Acrylic Adhesives DP810 DP810 NS. Technical Data June, 2004

Scotch-Weld. Low-Odor Acrylic Adhesives DP810 DP810 NS. Technical Data June, 2004 3 Scotch-Weld TM Technical Data June, 2004 Product Description 3M Scotch-Weld Low-Odor Acrylic Adhesive DP810 and DP810 NS are twopart, 1:1 mix ratio, toughened structural adhesives with less odor than

More information

Part and tooling design. Eastman Tritan copolyester

Part and tooling design. Eastman Tritan copolyester Part and tooling design Eastman Tritan copolyester Part and tooling design Process Part design Tooling design High cavitation considerations Process Process Project development flow chart Concept OEM generates

More information

ATL Fuel Level Sender Probes

ATL Fuel Level Sender Probes T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of

More information

Aspects of rheology to consider for different application methods

Aspects of rheology to consider for different application methods Aspects of rheology to consider for different application methods Alan Guy Safinah Ltd 28 th October 2015 www.safinah.co.uk Paint application Transfer of a liquid paint from a container to a substrate

More information

Two component epoxy paste adhesive

Two component epoxy paste adhesive Advanced Materials Araldite 2015 Structural Adhesives TECHNICAL DATA SHEET Araldite 2015 Two component epoxy paste adhesive Key properties Toughened paste Ideal for bonding GRP, SMC and dissimilar substrates

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

API Flanged Safety Relief Valves Series 526 CATALOG

API Flanged Safety Relief Valves Series 526 CATALOG API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes

More information

TECHANGLE November 30, 2005 TECHNICAL PAGE

TECHANGLE November 30, 2005 TECHNICAL PAGE TECHANGLE November 30, 2005 TECHNICAL PAGE The TECHANGLE wrench is an electronic torque and angle wrench. It is designed to provide basic electronic features, including UNITS CONVERSION, (Nm, ft-lb and

More information

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best Lovis 2000 M/ME Microviscometer ::: Viscometry at its best Lovis 2000 M/ME is a rolling ball viscometer which unites an established measuring principle (Höppler, DIN 53015 and ISO 12058) with innovative

More information

Approval Standard for Plastic Suspended Ceiling Panels

Approval Standard for Plastic Suspended Ceiling Panels Approval Standard for Plastic Suspended Ceiling Panels Class Number 4651 February 1978 2002 FM Approvals LLC. All rights reserved. Foreword The FM Approvals certification mark is intended to verify that

More information

OPERATION MANUAL INFRARED THERMOMETER

OPERATION MANUAL INFRARED THERMOMETER OPERATION MANUAL INFRARED THERMOMETER Features: Precise non-contact measurements Built-in laser pointer Automatic selection range and Resolution to 0.1ºor 1º / switchable button Automatic Data Hold & Auto

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

This test may be carried out with the IGT printability testers A1-3, A2-3 and AIC2-5 with the accompanying inking unit AE.

This test may be carried out with the IGT printability testers A1-3, A2-3 and AIC2-5 with the accompanying inking unit AE. This test may be carried out with the IGT printability testers A1-3, A2-3 and AIC2-5 with the accompanying inking unit AE. INTRODUCTION With absorption the speed is meant with which the ink penetrates

More information

Technical Data Sheet February 2014

Technical Data Sheet February 2014 Scotch-Weld Technical Data Sheet February 2014 Product Description s are high performance, two-part acrylic adhesives that offer excellent shear, peel, and impact performance. These toughened products

More information

METHOD OF TEST FOR UNIT WEIGHT OF FRESH CONCRETE

METHOD OF TEST FOR UNIT WEIGHT OF FRESH CONCRETE STATE OF CALIFORNIA BUSINESS, TRANSPORTATION AND HOUSING AGENCY DEPARTMENT OF TRANSPORTATION DIVISION OF ENGINEERING SERVICES Transportation Laboratory 5900 Folsom Blvd. Sacramento, California 95819-4612

More information

The entire document shall be read and understood before proceeding with a test. ISTA 3B 2013 - Page 1 of 35

The entire document shall be read and understood before proceeding with a test. ISTA 3B 2013 - Page 1 of 35 Packaged-Products for Less-Than-Truckload (LTL) Shipment ISTA 3 Series General Simulation Performance Test PROCEDURE VERSION DATE Last TECHNICAL Change: NOVEMBER 2012 Last EDITORIAL Change: JANUARY 2013

More information

Adhesive Transfer Tapes with Adhesive 200MP 467MP 468MP 467MPF 468MPF 7952MP 7955MP 7962MP 7965MP 9172MP 9185MP 9667MP 9668MP

Adhesive Transfer Tapes with Adhesive 200MP 467MP 468MP 467MPF 468MPF 7952MP 7955MP 7962MP 7965MP 9172MP 9185MP 9667MP 9668MP Adhesive Transfer Tapes with Adhesive 200MP 467MP 468MP 467MPF 468MPF 7952MP 7955MP 7962MP 7965MP 9172MP 9185MP 9667MP 9668MP Technical Data March, 2014 Product Description 3M High Performance Acrylic

More information

3M Thermally Conductive Adhesive Transfer Tapes

3M Thermally Conductive Adhesive Transfer Tapes Technical Data July 215 3M Thermally Conductive Adhesive Transfer Tapes 885 881 8815 882 Product Description 885, 881, 8815 and 882 are designed to provide a preferential heat-transfer path between heat-generating

More information

Fluid Dynamics Viscosity. Dave Foster Department of Chemical Engineering University of Rochester Email: dafoster@che

Fluid Dynamics Viscosity. Dave Foster Department of Chemical Engineering University of Rochester Email: dafoster@che Fluid Dynamics Viscosity Dave Foster Department of Chemical Engineering University of Rochester Email: dafoster@che che.rochester.eduedu 1 Chemical Engineering What do Chemical Engineers Do? Manufacturing

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION Sikadur-Combiflex REVISED JULY 2002 Sealing system for cracks and problem joints with large movements Construction DESCRIPTION USES ADVANTAGES The Sikadur-Combiflex joint sealing system consists of two

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information