ISDN PBX System. Installation manual AS 43, AS 45, AS 200 IT
|
|
|
- Pearl Kelly
- 9 years ago
- Views:
Transcription
1 ISDN PBX System Installation manual AS 43, AS 45, AS 200 IT
2 Saftey Notes - Installation and Maintenance of the System only by trained personnel. - Important! To prevent personal injury and damage to equipment please ensure that the system is properly earthed and that the appropriate cable is connected in the mains plug. - The System must be installed horizontal so that the connection panel is on the right hand side. - Do not connect or disconnect any PSTN lines during a thunderstorm. - Install lines and extensions in such a way that no one walks or trips over them. - Disconnect the System from the mains supply before opening the connection panel. Before connection of lines and extensions please ensure that the system is unplugged from the mains supply. DANGER! - Preventive measure! Before carrying out any installation work, please touch briefly the PC/ Printer socket of the telephone system. This will discharge any possible electrostatic charges, thus protecting the telephone system s electrostatically sensitive components. - Do not allow liquids to enter the system as short-curcuits may occur. - No liability will be accepted for consequential damages such as an unintentional continued connection of a line. - The telephone system will not operate in case of power failure and you will not be able to make any type of call. The AS 43, AS 45 and AS 200 IT can be connected to Basic Rate ISDN lines (DSS1, Point to Point, System Access, or Point to Multi Point, Standard Access) and may also be connected to analogue exchange lines. Should you operate your PBX-System on an analogue exchange line, then please ensure that your telephone service provider has meter pulse sending disabled as this may otherwise interfere with speech quality of a call. You may connect any equipment which has been approved for the connection to the Public Switched Telephone Network (PSTN) to the extension port of the system. Any DSS1 ISDN device which has been approved for the connection to the ISDN telephone exchange may be connected to the internal SO Bus. In addition you may connect up to two digital AGFEO System Phones to each SO Bus. Any other use of the telephone system which is not listed or described is prohibited. The telephone system has been issued with a universal connection licence. The system fulfils the specified conformity and safety regulations.
3 Table of contents Saftey Notes... 2 Check contents of delivery... 4 Open Connection Cover... 5 Closing Connection Cover... 5 LEDs of the AS 43, AS Installing and replacing modules... 8 Installation of AS 200 IT... 8 The K-Module Switchable SO Connections Short and Extended Passive Bus Internal S0 Bus configuration T-Module S0-Module Up0-Module AL-Module Differences to an ISDN Line CLIP at the Analogue Exchange K-Module System Interconnection Commissioning Tecnical Data
4 Check contents of delivery 1 Telephone System 1 Installation material (3 Wall Plugs S6,3 Wood Screws,Phillips 4x40) 1 RS 232 PC connection Cable 1 USB Connection Cable 1 Template 1 Instructions Pack 1 CD-ROM with TK-Suite and the AIS Konfigurator The operating instruction in PDF format can be found on our homepage Select Location Install the System in a dry room free of any hazardous materials. Avoid sites near Air Conditioners, Radiators, Equipment with excessive high radiation, direct sunlight, excessive dust and the danger of liquid spillages such as Water or Chemicals. Ambient Temperature 5C to 30 C. Max humidity 70% non condensing. The distance of the equipment to other objects such be considered to guarantee an air circulation. The minimum clearance distance of 50 cm should be adhered to. The distance of the system to the mains socket and the telephone network socket should not be more than 1 meter. (Length of mains cable 1.20 m) It must be made possible to place a Laptop or PC near the telephone system for programming. Mains Socket A separate mains socket for the telephone system should be installed. This will assist to give uninterrupted service in case that a mains fuse is tripped. The power consumption of the telephone system is approx 50 VA. Please ensure that the system cover is replaced before connecting the equipment to the mains. Warning! The telephone system must be electrically earthed. Please ensure that the mains socket is properly earthed before connecting the equipment to it. 4
5 Open Connection Cover Please unplug the telephone system from the 230 Main Socket before opening the cover. 1. Insert a screwdriver in the opening of the cover and press the screwdriver in the direction of the arrow. 2. Open the lid in the direction of the arrow. 3. Open the lid fully as shown in the picture. 4. Remove lid in the direction of the arrow. Closing Connection Cover 1. Insert carefully curved hinge into the designated catch. 2. Turn the lid in such a way that the straight hinge will fit into the designated catch. 3. Close the lid with light pressure until your hear the ratchet click into place. 5
6 Wall mounting The system must be mounted on the wall so that the connectors are at the bottom of it. Use the mounting 1, 2, and 3 to fix the equipment to the wall. - Use the template to mark the screw position. - Before drilling ensure that there is no Mains, Water or Gas supply hidden in the wall. - Use a masonry drill bit of 6 mm and drill to a depth of 40 mm, or - Wood Drill 3.5 mm Drill Depth 35 mm - Insert Wall Plug and Screw, Screwhead distance from wall approx 3 mm.-- - Place the system on top of the screws and pull downwards until in place. - Use last screw to secure system to wall. Moduleslots of the AS 43, AS 45 Moduleslot Interconnection Sockets (AS 45 only) USB Connection PC/Printer (RS 232C) (D-Sub 9-socket) Notes: The AS 43 offers moduleslots 1-3 only! 6
7 LEDs of the AS 43, AS 45 LED 1 LED 2 LED 3 LED 4 LED 1 (red) LED 2 (green) LED 3 (green) LED 4 (green) Permanentely Lit System is operational System is connected to the computer via USB Interconnection Active (AS 45 only) Flashes System being initialised Data being transferred USB Activity Interconnection not synchronised (AS 45 only) 7
8 Safety Notes Pay attention to the safety notes - before installing or removing a module, - before connecting or disconnecting a connecting lead 1. Remove the telephone system s 230 V mains plug from the socket. 2. Remove the Western plugs of all external ISDN basic accesses from the telephone system, the network terminator (NT) or the S0 bus. 3. Touch the metal shield of the PC/ printer socket on the bottom of the telephone system briefly with your finger. This will discharge any possible electro static charges, thus protecting the telephone system s lectrostatically sensitive components. Installing and replacing modules Installing a Module - Insert the module vertically, with the large connector strip pointing upwards, into the top hand bottom guide slits of one slot. - Carefully push the module down until the connectors engage and the latching lug of the module latches into the lock. - Pull the adhesive label showing the module s connections off the information sheet (included with the module packaging). - Stick the adhesive label over the module s slot on the housing. Replacing a Module - Undo the module s connecting leads. Mark the connecting leads clearly to avoid confusion on reconnection. - Press the lock upwards until the module s latching lug is free. Carefully pull the module out towards you. - Install the new module as described before. Installation of AS 200 IT Instructions on how to open an AS 200IT, installation of modules and patchfield are available in the installation instruction of the AS 200 IT, Ref. Nr
9 The K-Module 524 Connections: 2 SO connections switchable internal / external (external: PTP or PTMP internal: PTMP) 4 Analogue Extensions (POT s) b1 b2 a1 a2 external S0 b2: white a2: yellow b1: brown a1: green S01 S02 EXT/INT 100R EXT/INT b2 b1 a2 a1 b1 b2 a1 a2 b2 b1 a2 a1 b1 b2 a1 a2 100R EXT/INT : a2 4: a1 5: b1 6: b2 Western plug to the NTBA or to the IAE socket La1 Lb1 La2 Lb2 La3 Lb3 La4 Lb4 Connect Analogue Extensions You may connect any analogue apparatus to the system which has been approved for connection to the public switched telephone network. a/b-apparatus is: - Telephone (2 wire Phone or POT) either LD or MF Dialling with Timed Break Recall (TBR) ( ms) - LD Phones may only have limited feature access. - Fax machines Group 3 - Telephone Answering Machines - Modem 56k (V.90 to bps, may reduce to bps due to quality of lines V.34+) Connect the analogue apparatus via 2 wires to the a and b wire (Speech Pair) of the system port Connection of wire: - Strip the cable by 11 mm. - Push the single wire all the way into the connection block without pressing the release catch. - To disconnect a wire, press the release catch with a small screwdriver while at the same time pulling out the conductor 9
10 Switchable SO Connections External S0 Connections External S0-Connection You may connect the external SO Connection to a System Access (PTP) or Standard Access (PTPM) line. Please refer to External SO Connection (RJ45 Socket). Use the enclosed ISDN Cable and connect the four wires to the SO connection block of the module. - Push the wire all the way into the connection block without pressing the release catch. - Connector: a1 -green b1 -brown a2 -yellow b2 -white - To disconnect a wire, press the release catch with a small screwdriver while at the same time pulling out the conductor. - Guide the cable through the cable comb. Termination Resistors for the external SO Connection System Access (PTP) Both DIP Switches for the 100 Ohm Resistors must be closed or set to on. (Default Setting) Standard Access (PTMP) - Both DIP Switches (Page 1-7/8) must be - closed or set to on if the connection is made directly onto the NTTP or on the last socket which has no 100 Ohm Termination Resistors fitted. - open or set to off if the last socket has the 100 Ohm Termination Resistors installed or if the telephone system is not the last ISDN device on a PTMP line. Plug the ISDN Plug into the ISDN connection after completion of all installation work. 10
11 Internal S0 Connections You can connect up to 8 ISDN devices like on a PTMP connection on the internal SO Bus of the System. ISDN Apparatus: Digital AGFEO System Phones (max 2 digital phones per SO Bus) -ISDN -Telephones -ISDN -PC-Cards -ISDN Fax machines Up to four ISDN devices without additional power may be connected. For example: 4 ISDN Telephones or 2 Digital System Phones plus 2 ISDN Telephones. Connections of further ISDN devices will need their own power source. ISDN Apparatus must use the DSS1 protocol. You will need the following material to install an internal SO Bus. Telephone wire CW1308 (minimum 2 pair) or CAT5 Cable RJ45 Sockets max. 12 per Bus 2 Termination Resistors, 100 Ohm 0.25 W Maximum SO Bus length will be 130 m. (Telephone System to last RJ45 Socket) Termination Resistors for the Internal SO Connection The internal SO Bus must be terminated. Install two 100 Ohm Resistors in the last RJ45 Socket (See Diagram). Both DIP Switches must be closed (or set to on) Colour Code for Telephone Cable CW1308 SO Bus Contact Colour a1 4 Blue/white Bands b1 5 White/Blue Bands a2 3 White/Orange Bands b2 6 Orange/White Bands Colour Code for T568B (CAT5) SO Bus Contact Colour a1 4 Blue/White b1 5 White/Blue a2 3 White/Green b2 6 Green/White First Pair: a1, b1 Second Pair: a2, b2 UAE 1 S 0 - internal b1 a1 b2 a Max distance S0 Bus: 130 m Colour Code for T568 A (ISDN) SO Bus Contact Colour a1 4 Blue/white b1 5 White/Blue a2 3 White/Orange b2 6 Orange/White UAE UAE Most common used standard for SO Bus installation is T568B (CAT5) Ensure that pairs are not mixed up. UAE Ω 100 Ω 11
12 Installation and Termination of the S0 Bus It is important that the S0 Bus will be terminated with 100 Ohm resistors on the end of the line. Without termination the signals will be reflected on the line end and returned - similar to water when this hits an obstructions. The reflected signals will collide with the next received signals and destroy these. The result is that the S0 Bus will become faulty. Even though with the termination of four 100 Ohm resistors on either end of the "receive" and "transmit" circuit it may look as if the line is under heavy load but the resistors will have hardly any influence on the signalling voltage. A point to point installation will be terminated at the NTTP and the Telephone System itself, it will be imperative that with a Bus installation the line will always be terminated at the end of the circuit. Also, it is important that the line which is transmitting to the exchange is not reversed between sockets. As the signals have positive and negative pulses, a telephone which is sending positive signals my be received as negative on the other phone and may delete the positive impulses of that phone. The result will be that the S0 Bus will become faulty. Fault description and possible causes Calls a dropped. Intermittent fault. - Check the connection between telephone system and the connected sockets / distribution points. - Check that cables are correctly terminated. If possible use a meter and start at the system end. The exchange, the internal S0 Bus and all connected apparatus must be disconnected before measuring the line. - Most cases will show a loose connection. Disconnect the cable from the system and socket and then reconnect. Only one apparatus at a time will function on the Bus. - Please check that the wires between sockets are not reversed. If this is the case then one devise will function. However, more than one devise will cause interference between each other. High interference,instable lines, crackling in handset. - If the system is not operated via a plug in power supply, then it will be earthed via mains supply. Heavy interferences via earth can lead to crackling and even disconnection of calls. In order to establish if an earth problem exists, experiment and disconnect the earth momentarily or use an insulation transformer. Interferences from other devices - Some devices such as mechanical bells have a large interference potential and can lead to call disconnection. 12
13 Short and Extended Passive Bus Internal S0 Bus configuration Some technical aspects should be observed on the installation of an ISDN Bus and may require different settings. The telephone system is sending impulses in a specific "frame". The telephone exchange is expecting an answer of these frames from the connected telephone and devices. The time until an answer is received will vary and is depending on the cable length. The longer the cable the later the reply will be. The signal has to go through the cable twice (there an back). Due to this a important requirment should be observed. The telephones should not be to far apart that due to the running time of the signal the first bit of the distant phone will not coincide with the second bit of the nearer phone. Due to this the receiver of these bits cannot be seperated and the transmission will malfunction. Due to this two different Bus settings may be selected. Extended Passive Bus ( 0 to 1000 Metres) In this operation the receiver will search for the beginning of a receiving frame. With this it is able to adjust to a phone which is near and has a short running time and to a phone which is far away and has a long running time. Both at the same is not possible. On the contrary the search mode is very sensitive. Due to this the phone can only be apart for a maximum of 50 metres to ensure that the impulses will be near to equal timing. This could be 400 metres and 450 metres or 25 and 75 metres. Short Passive Bus ( 0 to 130 Metres) The restriction of 50 metres between telephones on a bus installation is not always possible. Due to this there is a second operational mode. In this mode the search facility is switched off. The receiver is expecting the time frame in a specified time window. This window is relative large and allows for a distance between telephones from 0 to 130 metres. For example a telephone may have a distance of 5 metres and another one of 130 metres from the exchange or telephone system. The maximum distance of a device to the exchange should not exceed 130 metres. However, this will also depend on the cable used. This mode is to be suggested for star wiring installation. You will find this option in the remote configuration tool in the "Option internal S0" 13
14 T-Module 508 The T Module 508 features 8 interfaces for analogue extensions. This module supports the CLIP function. You may connect any analogue apparatus to the system which has been approved for connection to the public switched telephone network. a/b-apparatus is: - Telephone (2 wire Phone or POT) either LD or MF Dialling with Timed Break Recall (TBR) ( ms) - LD Phones may only have limited feature access. - Fax machines Group 3 - Telephone Answering Machines - Modem 56k (V.90 to bps, may reduce to bps due to quality of lines V.34+) Connect the analogue apparatus via 2 wires to the a and b wire (Speech Pair) of the system port Connection of wire - Strip the cable by 11 mm. - Push the single wire all the way into the connection block without pressing the release catch. - To disconnect a wire, press the release catch with a small screwdriver while at the same time pulling out the conductor Lb1 La1 Lb2 La2 Lb3 La3 Lb4 La4 Lb5 La5 Lb6 La6 Lb7 La7 Lb8 La8 14
15 S0-Module 540 The S0 module features the following interfaces: 4 Switchable internal / external S0 interfaces external: ISDN basic access as a point-tomultipoint or point-to-point connection internal: point-to-multipoint connection Switching to an internal S0 access Set both DIP-switches ext./int. of the respective S0 access to int. - position (ON). Switching to an external S0 access Set both DIP-switches ext./int. of the respective S0 access to ext. - position. Terminators (100 Ohm) Activate - set both DIP-switches off/on of the respective S0 access to on -position (ON). Deactivate - set both DIP-switches off/ on of the respective S0 access to off - position. See Page 10 to 13 for further hints for a correct termination of an external or internal S0 access. b1 b2 a1 a : a2 4: a1 5: b1 6: b2 external S0 b2: white a2: yellow b1: brown a1: green Western plug to the NTBA or to the IAE socket S01 S03 S02 S04 EXT/INT 100R EXT/INT b2 b1 a2 a1 b1 b2 a1 a2 b2 b1 a2 a1 b1 b2 a1 a2 100R EXT/INT EXT/INT 100R EXT/INT b2 b1 a2 a1 b1 b2 a1 a2 b2 b1 a2 a1 b1 b2 a1 a2 100R EXT/INT 15
16 Up0-Module 508 The UP0-Module 508 can support of up to eight AGFEO Up0 System Telephones. Please note that in order to operate an Up0 Module it will be imperative that a system firmware from 7.5 is installed. Connections of Extensions: - Strip the cable by 11 mm. - Push the single wire all the way into the connection block without pressing the release catch. - To disconnect a wire, press the release catch with a small screwdriver while at the same time pulling at the wire. - The wires are to be connected to contact 4 and 5 of the socket. - The Up0 Module is NOT polarity conscious. - Please note you can only connect 1 apparatus to each Up0 connection. A termination resistor is NOT required. Lb1 La1 Lb2 La2 Lb3 La3 Lb4 La4 Lb5 La5 Lb6 La6 Lb7 La7 Lb8 La8 16
17 AL-Module 4504 You may connect up to 4 analogue exchange lines to this module. The module supports DTMF dialling and CLIP, however the latter would have to be enabled by your network operator and may be chargeable. Should your network operator support CLI, then this will be presented via the AL4504 module to the system. CLIP* will also be entered into the call log and call management system. (*CLIP (Calling Line Identity Presentation) is a feature which will display the telephone number and or name of the calling party before you answer the call.)the PABX compares the received CLIP information with the entries of the system telephone book and if a match is found will replace the calling telephone number with the name as it is entered in the system telephone book. This information will also be used by the call log and call management system. CLI will also be presented to analogue caller id telephones. If necessary the AL4504 can be updated. Differences to an ISDN Line Unlike to the protocol based ISDN line, the apparatus connected to the analogue line will not receive a call progress report from the telephone network. For instance the connected device on an analogue line will not receive a confirmation that the called party has answered the call. This will result in the following difference between an analogue exchange line and an ISDN line: The moment the exchange line has been seized is the time the call will be logged as to have taken place. TK Suite Bill will log a call as being completed or have taken place as soon as an exchange line has been seized, even if the line is still ringing or engaged. MF overdialling is possible but will not be recognised by the system as such. This will result that the complete telephone number and overdialled number will be stored in the call log and last number redial. CLIP at the Analogue Exchange In default the PABX is set that an incoming call will ring an extension without using the CLIP function. However, you may enable this function by changing the setting in Wait for CLIP. The forwarding of the CLIP information from the telephone network may take up to 5 seconds, during this time the system will be idle. Therefore the extensions will ring with a delay of up to 6 seconds. It may be useful to make use of the function Wait for CLIP if this information will not be displayed at your extension, or if you use a call filter or SMS messaging via the analogue line. Notes Further installation and programming information of the AL Module 4504 are available the installation instruction of the AL-Module 4504, Ref. Nor
18 Important Notes Remote programming and Remote Updating of the PABX and or AL Module 4504 will not be possible when using an analogue exchange line only. The AL-Module 4504 DOES NOT support meter pulses from the exchange. To avoid malfunction, please ensure that meter pulses are disabled from the relevant telephone provider. Connection of Analogue Lines Connecting the wires: - Strip 11 mm of insulation from the wires. - Slide the individual wires into the clip up to the insulation without pressing the spring clip. - Push - To release a wire, press the spring clip down using a suitable object (small screwdriver) and pull out the wire. Line 1 Line 2 Line 3 Line 4 Tip 1 Ring 1 Tip 2 Ring 2 Tip 3 Ring 3 Tip 4 Ring 4 18
19 K-Module 544 The AGFEO K-Module 544, is for the Telephone Systems AS 43, AS 45 and AS 200 IT from firmware 7.1 and will support the following three communications sections. These are: Alarm Section: 4 alarm input contacts with independent voltage supply + 12 V 250 ma Door Phone Section: 3 Analogue Extensions (SLT) with CLIP for analogue phones, fax machines or AGFEO Door Phones. With 2 Switching Relays. Audio Section: Audio input with a 3.5 mm socket for MoH and background music. Audio output with symmetrical 0.8 Watt/8 Ohm for loudspeakers, switchable as pre-amp output (asymmetrical) for an external amplifier. Connections of K-Module 544 AL 1 IN AL 1 - AL 2 IN AL 2 - AL 3 IN AL 3 - AL 4 IN AL 4 - AL + AL + U-1 U-2 La1 Lb1 La2 Lb2 La3 Lb3 KT 1 KT 2 TO 1 TO 2 TS 1 TS 2 REL 1-1 REL 1-2 REL 2-1 REL 2-2 LS 1 LS 2 AUDIO-ASYM GND AUDIO IN Signalling Input Sensor 1 Ground Signalling Input Sensor 2 Ground Signalling Input Sensor 3 Ground Signalling Input Sensor 4 Ground 12V Supply Voltage 12V Supply Voltage Transformer for Dooropener for doorphone with 2-wire-standard connection Extension 1 / Doorphone Connection for doorphone with 2-wire-standard connection Extension 2 / Doorphone Connection for TFE FTZ 123 D 12 Extension 3 / analogue 2-wire doorphone (e.g., AGFEO TFE 2/4) Bell Push for FTZ 123 D 12 TO for TFE FTZ 123 D 12 TS for TFE FTZ 123 D 12 Switching Relay 1 Switching Relay 2 Audio output with symmetrical 0.8 Watt/8 Ohm for loudspeakers pre-amp output (asymmetrical) for an external amplifier Audio Input for MoH Notes Further installation and programming information of the K-Module 544 are available the installation instruction of the K-Module 544, Ref. Nor
20 System Interconnection It is possible to interconnect 2 AS 45 s or 2 AS 200 IT s and therefore increase the maximum number of port to 80. Of these 48 ports may be used for System Phones or System DECT s. The modules, with the exception of the LAN Module, may be inserted into any module slot of the interconnected telephone system. The following points with reference to the interconnection of two systems should be observed: - If the telephone system is operated on a Point to Multi Point line, then a permanent active external S0 must be connected to the first S0 of the Master Cabinet. - If the telephone system is operated on a Point to Point line, then at least one external S0 must be connected to the Master Cabinet. - Like with the AS 45 up to 48 STE 30 s or STE 40 s may be connected. - System programming will only be possible via the serial- or USB connection of the master cabinet. These connections are without function on the slave unit. Programming via the S0 Bus is possible on either cabinet. - CTI via the serial- or the USB connection will only be available at the master cabinet. If you want to utilise CTI from various computers (Network), then a telephony server must be made available at the master system. - Both system must be of the same firmware level. For this the master system must be updated, the slave system will automatically being updated. Master Connection: The system on which this connection is used, is the MASTER SYSTEM (CABINET) - Disconnect both AS 45 s or AS 200 IT s from the Mains Socket. - Connect the Master socket from one system to the Slave socket of the other system. Please use a shielded network cable (at least CAT5). Please note that the length of this cable cannot exceed 1 metre. - Power up both systems. - Please wait until LED 4 is permanently lid. As before, you now can program the system via TK Suite. 20 Slave Connection: The system on which this connection is used, is the SLAVE SYSTEM (CABINET)
21 Connecting a printer for printing connection charges You can connect any printer to the telephone system s RS 232C interface to print out connection records. For connection, you need a cable that corresponds to the pin assignments given below (maximum length 3 m). Your printer must be set as follows: baud - 8 bits - 1 stop bit - no parity To print out connection records, the printer must be on all the time and must be connected to the telephone system. The telephone system stores 2000 connection records and the total connection charges, even in the event of a power failure. telephone Telefonanlage system Drucker printer (9-Pole (9pol. Stecker) connector) (25-Pole (25pol. connector) Stecker) Commissioning You have installed the system. However, before you can make a call you must do the following: - Connect the extensions. You may connect any apparatus which you are allowed to connect to the public switched telephone network. - Connect the RJ 45 plug to the ISDN network or connect the relevant connection cable to the analogue network. - Switch on the telephone system by plugging the mains plug into the mains socket. Programming to the users requirement can be carried out via the connection of a PC. The remote programming of the system may be carried out via your dealer. Notes To avoid calling wrong telephone numbers please ensure that the following is carried out. After installation of the system please dial from an analogue MF telephone a single digit, this ensures that the system recognises the correct dialling method for the relevant extension. Should you change to a telephone which is dialling in LD, then you must dial a digit higher then 2. Should you operate two telephone on one port, then you must ensure that both phones connected are of the same dialling method. 21
22 Tecnical Data Specification ModularISDN Telephone System with 5 Expansion Slots and On board Interconnection ( AS 43: 3 Expansion Slots, no Interconnection) Expansion Modules - K-Module S0-Module T-Module AL-Module Up0-Module K-Module 544 Measurements Weight 2 S0 connections switchable internal / external, 4 Analogue Extensions (POT s) 4 S0 connections switchable internal / external 8 Analogue Extensions (POT s) 4 Analogue Trunk Lines 8 Up0 Ports 4 alarm input contacts, 3 Analouge Extensions or 1 FTZ 123D12 Door Phone, 1 two wire Door Phone and 1 analogue two wire doorphone (e.g. AGFEO TFE 2/4), 2 switching Relays, 1 audio ouptut symmetrical for loudspeakers, switchable as pre-amp output (asymmetrical) for an external amplifier, 1 Audio Input for external MoH 26 x 32 x 12 cm (High x Width x Depth) 3,4 kg Ambient temperature - Operation/Storage Humidity Mains Connection Power Consumption - AS 45 - AS 43 External S0 Connection fixed - Connection Switchable Connection 5 C to 40 C / -25 C to +70 C max. 70 % (none condensing) 230 VAC, +6%/-10%, 50 Hz P max = 60 W P max = 40 W PTP or PTMP connections, Euro ISDN 2e via RJ 45 Socket and enclosed connection cable SO connection internal / external switchable (DIP Switches) external: PTP or PTMP connection Euro ISDN 2e (DSS1) internal: PTMP connection, Euro ISDN 2e (DSS1) 22
23 Tecnical Data - Connection - Length - Power Consumption internal S0 - ISDN-Apparatus 4 wire spring loaded connectors max lenght of internal SO Connection dependent on the mode - Short passive Bus 130 m - Extended passive Bus 1000 m 4,5 Watts max. 8 Up0-Connection - Connection - Length 2 wire spring loaded connectors 800 m Analogue Apparatus - Distance - Connection - Dial Method - Enquiry Button PC/ Printer Connection - Range/ Level - Connector USB Connection - Cable Length Switching Relays - Contact Load Audio Output Audio Input 2 x 50 Ohm (diam. 0,6 mm, 800 m) 2 wire spring loaded connectors DTMF or LD Flash ( ms). RS 232C 3 m / +/- 5 V 9 pin D-Socket Universal Serial Bus 3 m Spare contact with surge arrestor 1 kohm / 100 nf 30 VDC/1 A or 125 VAC/0.5A, resistive load 1 kohm, 100 nf 0,8 Watt /8 Ohm symmetrical 0,4 Watt /4 Ohm asymmetrical Initial resistance 50 K Ohm 23
24 The crossed out wheeled bin on the product means that this belongs to the group of Electro- and electronic apparatus. In this context you are directed by the European regulation to dispose of used apparatus - at the point of buying an item of equal proportion / value - at the local available collection point for disposal With this you will participate in the reuse of material and valorisation of disused electric- and electronic apparatus, which otherwise could be a health hazard and be negative to the environment. Ident no Subject to change without notice. No liability can be accepted for errors contained in this document. Printed in Germany 0067 AGFEO GmbH & Co. KG Gaswerkstr. 8 D Bielefeld Internet:
PBX System. Installation Manual AS 200 IT
PBX System Installation Manual AS 200 IT Safety Notes - Installation and Maintenance of the System only by trained personnel. - Important! To prevent personal injury and damage to equipment please ensure
ISDN PBX-System. Manual. Business-Line: AS 1x, 2x, 3x
ISDN PBX-System Manual Business-Line: AS 1x, 2x, 3x Safety Notes - Installation and Maintenance of the System only by trained personnel. - Important To prevent personal injury and damage to equipment please
System Phone. User Guide. System DECT 35
System Phone User Guide System User Instructions The AGFEO Cordless System Phone is designed for the connection / registration to an AGFEO DECT S0 Base or an AGFEO DECT S0-Base plus. The AGFEO will be
XN120 Getting Started Guide Rev 1.2 (March 2005) 991409-5
This guide explains the installation, configuration and operation of the XN120 Telephone System including the exchange line and telephone connections. Further information will be supplied with any optional
Operating Instructions. Telephone System tiptel 1/8 fax clip tiptel 2/8 clip. (Release 2) tiptel
Operating Instructions (UK) Telephone System tiptel 1/8 fax clip tiptel 2/8 clip (Release 2) tiptel Table of Contents Connection of 8 extensions..........3 Connection of 7 extensions and 1 door intercom................4
User manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
How To Use A 1232 On A 1236 On A Computer Or A Cell Phone
12-36-1000 Autodialler and Relay Telephone Interface 1.0 INTRODUCTION 12-36-1000 I/O Telephone Interface with AutoDialer The 12-36-1000 is a autodialer and telephone interface that can be used autonomously
TCR easy Plus Alarm. Operating Instructions
TCR easy Plus Alarm Operating Instructions Table of Contents General.....................................4 Installation...................................5 Putting into Operation............................5
ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English
xepi 2 Diagnostic Unit and Configuration Interface Doc. Version 4.0 Installation Guide English Dear Customer, This "Installation Guide" will help you to install the hardware. If you have any further questions,
GSM Desktop phone DPH101. User manual v1.00
GSM Desktop phone DPH101 User manual v1.00 LEGAL NOTICE Copyright 2011 TELTONIKA Ltd. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Enterprise Telephone. Model 98390 OPERATING INSTRUCTIONS
Enterprise Telephone Model 98390 OPERATING INSTRUCTIONS This Interquartz telephone has been manufactured to very high standards and is very easy to use. Please read this manual carefully to find out how
Installation Manual for D0700 ISDN Analogue Converter
Installation Manual for D0700 ISDN Analogue Converter Dycon Ltd Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconsecurity.eu [email protected]
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
IP DSLAM IDL-2402. Quick Installation Guide
IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
Bluetooth HC-06 with serial port module Easy guide
1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide
Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT Active Speaker System with remote input LX523 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
TS510 & TS500. Installation & User Guide. Compatible Equipment
Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction
OPERATING INSTRUCTIONS
Gemini Speakerphone OPERATING INSTRUCTIONS This Interquartz telephone has been manufactured to very high standards and is very easy to use. Please read this manual carefully to find out how to use the
Business/ Home GSM Alarm System
Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before
Euroset 5005. Connections
Euroset 5005 Connections 1 Repertory keys 2 Recall key 3 Redial key 4 Handset volume control key 5 Pause key 6 Speed dial key 7 Set key 8 Mute key 1 Touches d accès rapide 2 Touche de double appel 3 Touche
8 Channel Status Input Panel model SIP-8
Description The Sine Systems model SIP-8 Status Input Panel is to be used with the RFC-1/B Remote Facilities Controller. It consists of a long PC board mounted on a 1.75 inch (1U) rack panel. The SIP-8
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Memcom Emergency Telephone
Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming
Getting Started. Table of Contents. Hybrid IP-PBX
Hybrid IP-PBX Getting Started Model no. KX-TDA30 Table of Contents 1 Before Installation... 2 2 Installation... 4 3 Starting the Hybrid IP-PBX... 11 4 Customising the Hybrid IP-PBX... 14 5 Confirming the
Installation and Configuration Manual. for the Administrator. ISDN PBX Systems. COMpact 4410 USB COMpact 2206 USB
Installation and Configuration Manual for the Administrator The PBX is able to download the latest firmware by pressing a button or by time automation. The manual has information about being up-to-date
PBXs for analogue/isdn and Internet telephony
Installation and Commissioning Instructions PBXs for analogue/isdn and Internet telephony COMpact 5010 VoIP COMpact 5020 VoIP Symbols used This symbol warns of personal injury, for example, caused by hazardous
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
General notes: To avoid problems, always use:
Questions and answers If you have any questions about the use of your phone, you can contact us at www.gigaset.com/service at any time. For more information about combining different Gigaset devices, visit:
Model PBX 308 System Administration Guide
Model PBX 308 System Administration Guide Introduction 4 Installation Hints 4 Wall Mounting System Programming 5 System Password Changing the Password IMPORTANT Exchange Lines 6 1 Exchange Line connected:
BT Big Button 100. User Guide
BT Big Button 100 User Guide Welcome to your BT Big Button 100 phone Large buttons for easy dialling. Handsfree make and receive calls using the loudspeaker. One-touch 1571 button dials your network answering
Installation and Maintenance Manual
Installation and Maintenance Manual Mitel 3000 Installation Manual 1 Contents Safety Regulations... 4 Important Safety Instructions... 4 Introduction... 6 General overview... 6 Safety Precautions during
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
Shunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
WF720 Wireless Home Phone User Manual
WF720 Wireless Home Phone User Manual Content Getting to Know Your Device... 3 Appearance...3 LED Indicator...4 Device Installation... 5 Before You Begin...5 Installing the SIM Card and the Battery...5
Wind Sensor W-RS485 with RS485 Interface
Wind Sensor W-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
Getting started with
PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
VOICE RECORDING SYSTEM ISDN PRI / BRI
Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual
CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: 01825 733600 LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual Contents 1) Operation 2)
Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)
February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,
AUTODIALLER / QUICKDIALLER - SA132
AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING
TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?
TO-PASS -FAQ- Remote Monitoring What is TO-PASS used for? TO-PASS modules are used as/for: Permanent online connection Fault detectors Remote data polling Data storage Telecontrol module What are the special
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
GSM Gate Opener GSM Remote Switch RTU5015 User Manual
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide
GB05-6 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2012 In the interests of development, information
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
ANTI-THEFT SYSTEM. 1995 Volvo 850 DESCRIPTION & OPERATION BASIC ALARM. 1995-96 ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems
ANTI-THEFT SYSTEM 1995 Volvo 850 1995-96 ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems 850 DESCRIPTION & OPERATION WARNING: Deactivate air bag system before performing any service operation. For 1995
ECR Shelf System Installation Guide Centralized Rack Mount Call Recording
Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: [email protected] [email protected] www.algosolutions.com
InnoMedia ESBC 9580-4B. Quick Install Guide. www.innomedia.com 1
InnoMedia ESBC 9580-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
Mini-PBX Telephone Switching System User and Installation Guide
Mini-PBX Telephone Switching System User and Installation Guide Model: TSS308GE-A NZ Imported, Distributed and Serviced by: Atlas Gentech (NZ) Limited 87 Carbine Road Mt Wellington Auckland NZ Ph: (09)
3x cinch/s-video socket Order no.: 33 1532 xx. USB/3.5 mm audio socket Order no.: 33 1539 xx. VGA socket Order no.: 33 1540 xx
3x cinch/s-video socket Order no.: 33 1532 xx USB/3.5 mm audio socket Order no.: 33 1539 xx VGA socket Order no.: 33 1540 xx VGA socket with screw-in lift terminals Order no.: 33 1541 xx High definition
QUICK INSTALLATION GUIDE
QUICK INSTALLATION GUIDE (v. 1.1) WARNING: This is a class A product. In a domestic environment this product may cause radio interference
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Model PBX 308 Plus System Administration Guide
Model PBX 308 Plus System Administration Guide Introduction 3 Installation Hints 4 System Programming 5 IMPORTANT Exchange Lines 6 Assign Incoming calls to ring Nominated Extensions 7 Cascade Ringing Of
SmartLogger1000. Quick Installation Guide. Issue 05. Date 2013-12-15 HUAWEI TECHNOLOGIES CO., LTD.
Issue 05 Date 2013-12-15 HUAWEI TECHNOLOGIES CO., LTD. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D
Tele Eye DT Series Dialup CCTV Transmitter DT-103G DT-103P DT-103D Installation Guide Notice: Signal Communications Limited reserves the right to make improvements to the product described in this manual
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
MANUAL PC1000R [email protected]
MANUAL PC1000R [email protected] Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
10000HXL31/15000HXL31/20000HXL31
Table of Contents www.eaton.com/dxups USER MANUAL ON LINE UPS 10000HXL31/15000HXL31/20000HXL31 Uninterruptible Power Supply Table of Contents 1. Brief introduction 1.1 System and model description---------------------------------------------------------------------1
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
User Manual. Video Doorphone CDV-1020AQ
User Manual Video Doorphone CDV-1020AQ 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the