1 Engineering Onboard Climate Control Experience for optimal design

2 O F F S H O R e H v a c - R A d v a n t a g e s 2 K n o w l e d g e f o r o p t i m a l e f f i c i e n c y The BRONSWERK Advantage BRONSWERK Onboard Climate Engineering offers complete integrated HVAC and Refrigeration systems, products, and support services for offshore drilling platforms, their residential accommodations and the work boats that service them. At BRONSWERK we are driven to excellence in HVAC-R design and are at the forefront of innovation. We know that offshore systems must withstand the most rigorous and often hazardous environmental conditions, and offer prolonged reliability. Our mission is to protect workers health and safety by ensuring that risk in offshore workplaces is properly minimized. BRONSWERK s commitment to you is to deliver you an innovative, tailored HVAC-R solution at a competitive price, and on time. Our engineers offer more than 250 years of cumulative experience, with a solid depth of knowledge in HVAC-R engineering and system design. We are sea experts; we know how rigorous and varied climate conditions can be in offshore platform locations. Our products and installations exceed the highest standards for performance, space optimization, weather resistance, reliability and noise and vibration reduction. We service your business with a highly efficient, dedicated team. Our relationship with you begins with consultation to clarify objectives, deliverables and expectations. Preliminary design is followed by detailed execution and final preparation of your offshore HVAC-R systems. Our involvement extends into the integrated design phase and our team provides ongoing system support. BRONSWERK quite simply offers quality and innovation unmatched in the industry, together with complete lifecycle support. We are understandably proud of our 100% client satisfaction and referral rate. We provide HVAC-R systems to offshore drilling platforms, their residential accommodations and the work boats that service them.

3 Q U A L I T Y S Y S T E M S. I N N O V A T I V E D E S I G N S. All systems offer extremely high reliability and are designed for quick recovery Your custom HVAC-R products undergo extensive testing at our factory before being shipped to you for installation. B R O N S W E R K O F F S H O R E H V A C - R

4 From design to implementation, we deliver engineering ingenuity. R e n o w n e d E n g i n e e r i n g E x c e l l e n c e E n g i n e e r i n g e x c e l l e n c e a n d i n n o v a t i o n a r e t w o o f o u r k e y s t r e n g t h s. Our engineers have deep combined experience in worldwide offshore HVAC-R systems. All projects, regardless of scale, receive equal priority from your dedicated team: a project manager, engineers and detail designers. Your BRONSWERK team works to identify and meet each individual client s needs. We offer support throughout all project phases from advising on system modifications should the design change to ensuring that customer care extends beyond the product delivery stage. Offshore HVAC-R and Special Projects have been engineered for locations worldwide, including drilling barges, semi-submersible drilling platforms and FPSOs off USA, Korea, Canada, Norway and Russia. We have partnered on the Hibernia, Sable Island, Terra Nova, Petrodrill and North Sea projects among others. For offshore platforms, satellite habitation units and work boats, Bronswerk project deliverables include: Heat load analysis Conceptual, basic and detailed system design Tailored equipment design and manufacturing to meet special needs Procurement of components and materials Installation and/or on-site installation supervision (when required) ILS Documentation Maintenance Training Testing and commissioning HVAC-R and system warranty After-sales service and spare parts (worldwide) B R O N S W E R K O F F S H O R E H V A C - R

5 BRONSWERK on-board climate systems for offshore platforms feature innovative, high-performing and reliable technology. We offer efficient systems that are able to adjust to the rigorous sea and weather conditions. Whether the platform is located in the Gulf of Mexico or the North Sea, our systems ensure the crew s comfort and safety while climatically controlling your equipment environment. O F F S H O R E H v a c - R E N G I N E E R I N G S K I L L S 5 H I G H - P E R F O R M A N C E T E C H N O L O G Y BRONSWERK offshore HVAC-R systems maintain designated levels of temperature, air change rate, humidity, fresh air quality and pressure. They provide cooling for high internal heat-gain spaces, and are quiet and low-vibration. Our products are compact and designed for platform space optimization. Your HVAC-R installation must perform in a challenging, remote sea location and be subject to severe climactic conditions, so high reliability is essential. Equipment exposed to extreme weather is constructed of stainless steel, marine-grade aluminum or titanium to ensure longevity. High-efficiency louver filtration systems are installed to remove the salt, water and dirt particles that can be present in offshore environments. Also, since these locations are not typically readily accessible, a logistic and life-cycle support program is essential. S a f e t y f e a t u r e s Safety is a critical concern to your crew. Installations are shock resistant and explosion protected. Our engineers address fire and explosion issues when designing for offshore installations including prevention, control and mitigation. Your system must perform regardless of hazards, including loss of platform stability (arising from collision or uncontrolled flooding), loss of position or emergency ingress of fire, smoke and gas. In addition to ingress prevention or accumulation of potential harmful gases, the offshore HVAC system may be called upon to support life and essential equipment operation during emergency situations (an internal pressure control system is considered for these situations). Inlets and outlets are protected by fire and gas dampers, and shut-off dampers are both automatically and remotely closeable. HVAC fire dampers must close on demand so as not to compromise the quality of the atmosphere in the temporary refuge (TR) space. The dampers provide fire protection for the structure and HVAC inlet & outlet ducting, and also provide some sealing function to prevent excessive air outflow. Internal pressurisation is necessary to prevent air leakage from doors, windows, drain systems and through the structures cladding. They must perform for the specified TR endurance time; normally up to 2 hours. Your HVAC-R custom designed products undergo extensive testing at our factory before being shipped to you for installation to ensure they meet the highest quality and safety standards. All systems offer extremely high reliability and are designed for quick recovery after a platform emergency. TSR Starter Cabinet The B R O N S W E R K p r o j e c t r o a d m a p consists of five principal stages: 1. Project Kick-Off In this phase we plan your project and lay the foundations for successful implementation. We make and share the strategic decisions that are crucial to your project: Define your system goals and objectives Clarify the scope of the system Define your project schedule, budget plan, and execution sequence Establish the project organization, including representatives from your organization 2. System Preliminary Design In this phase we deliver the Single Line Diagrams and supporting Heat Load Calculations to ensure that the design will meet your specified needs. If platform and habitation vessel modifications are made during this stage, we modify the HVAC-R design accordingly. 3. System Detailed Execution With your agreement on the preliminary design, in this phase the team prepares all the supporting detailed engineering work: Equipment Diagrams Special Equipment Designs Complete Equipment Lists Hot Water/Chilled Water Diagrams Detailed calculations to ensure that the system conforms to acceptable levels of pressure drops, noise, and vibration. During this phase we also deliver the actual equipment and ducting that make up your system and, if desired, we install the HVAC-R system or oversee the installation. We also manufacture any equipment that is required to meet your needs and conduct Factory Acceptance Tests in our premises to certify that the equipment meets the highest standards. 4. System Final Preparation In this phase we deliver training, as well as conduct the required testing and commissioning. It is critical to train maintenance personnel to protect your investment. We offer instruction at our training facilities on both system and special equipment for operators, crew maintainers and shore maintainers. Sea Acceptance Testing and Commissioning is complete and rigorous. 5. Platform Launch & Support In this phase BRONSWERK supports you to ensure that your HVAC-R system is operating efficiently. Our warrantees ensure that you are well protected. We offer outstanding after-sales support on every continent through our global support network.

6 O F F S H O R E H v a c - R T Y P E O F H V A C S Y S T E M S 6 C U S T O M I Z E D O F F S H O R E V E S S E L H V A C - R S O L U T I O N S INNOVATION FOR THE FUTURE AHU for Fan Room BRONSWERK designs HVAC-R solutions for offshore platforms, habitation vessels, work boats and, when required, designs and manufactures special equipment. We are industry specialists in Environmental Control Systems. Due to the severe conditions in which offshore platforms operate and their space limitations, ECS systems must be reliable and easy-to-use, operate and maintain. These predominantly all-air systems deliver a clean and safe environment for offshore platform personnel. Local cooling is provided to spaces with high internal heat gain as well as to those spaces which are remote from the main distribution system. These units can be explosion-proof if necessary. Chiller A L L - A I R S Y S T E M S For offshore platform installations, BRONSWERK engineers primarily all-air systems that provide complete sensible and latent cooling capacity. Heating can be accomplished with the same air stream, either in the central system or at a particular zone. A single airhandling unit can provide heating and cooling to multiple compartments. The outside air is mixed with the return air from the conditioned space. Individual adjustment of temperature can be done manually by opening / closing the supply air terminal boxes. System Advantages (+) 1. The central plant is located in unoccupied areas, thereby facilitating operation and maintenance, controlling noise and enabling choice of suitable equipment. 2. Gives a wide choice of zonability, flexibility, and humidity control under all operating conditions. 3. Allows good design flexibility for optimum air distribution, draft control and local requirements. 4. Well suited to applications requiring unusual exhaust makeup. 5. Adapts to winter humidification. 6. Improved air quality. 7. Control of noise levels. C H I L L E R S We custom design and manufacture water chillers that meet your specific requirements. These incorporate a water-cooled condenser that can include copper tubing and cast steel heads depending upon the requirements. The compressor is either open-hermetic or screw-type and the multi-circuit water cooled evaporators are plate or shell & tube. BRONSWERK chillers also include a customized Programmable Logic Controller (PLC) which interfaces with the ship s control system. A I R H A N D L I N G U N I T S Air Handling Units for offshore come encased by a double-skin enclosure that is insulated throughout. Noise is minimized with our custom-designed, low-profile Integral Discharge Silencer. All fans, coils and controls meet marine-grade standards. The unit comes to you pre-wired, with piping connections extended to the exterior, and are ready for shipboard mounting. Other specifications include: Stainless steel 316L designed casing Dual fans with inlet guide vanes and non-return dampers for redundancy Chilled water cooling coil in stainless steel casing Steam heating coil with Cu-to-Cu fin tube in stainless steel frame Disposable filters and individual section cleanouts High-pressure design Integrated lifting beam for equipment servicing Direct-injection steam humidification from dedicated steam generator

7 Fire Dampers F I R E M A N S P A N E L S Fireman s Panels are configured for emergency operations under Black Start conditions and allow for quick emergency connection for portable air supply. They are constructed with a stainless steel piping manifold and control valves, and include individual & group damper controls for the various fire zones. There are separated normal control and emergency control valves, and there is an optional damper position indication within the panel. A local test valve is also fitted, for routine inspection and operational testing. Engraved valve label plates are clear and highly visible. F I R E / S M O K E D A M P E R S BRONSWERK offers hazardous and safe area-rated control packages that are customized to your requirements. Our high-performance dampers are pneumatically actuated and designed to close in under one second (1 sec.). They are individual section and matrix to maximize opening sizes, and made of either stainless steel or galvanized steel, based on individual client needs. BRONSWERK also offers additional features such as composite or stainless steel actuators, with fail-safe spring return and individual section open/closed proximity sensors or microswitches if required. R E F R I G E R A T I O N C O N D E N S I N G U N I T S Our refrigeration condensing units are designed to be semi-hermetic and compact. They include compressors with stage control and stacked-unit setup to minimize their footprint, and their dual-design ensures 100% redundancy. Other features which are available: customized controls, integral starter and water cooler, oil cooler and heat exchanger rack. Refrigeration Condensing Units use the customer s selected refrigerant. O T H E R H V A C - R P R O D U C T S Condensing Units Ducting Fans Fan Coil Units Salt/Spray Eliminators Multiple Stages Intakes B R O N S W E R K O F F S H O R E H V A C - R

8 W O R L D W I D E K N O W - H O W Canada United States Denmark Germany China Finland Korea Indonesia Netherlands Chile Turkey Spain United Kingdom Mexico France Belgium w w w. b r o n s w e r k g r o u p. c o m W O R L D W I D E K N O W L E D G E E N G I N E E R I N G I N N O V A T I O N BRONSWERK Onboard Climate Engineering, headquartered in Montreal, Quebec, Canada, is a premier global provider of complete marine HVAC-R solutions for the merchant marine, military and offshore industries. BRONSWERK customized HVAC-R solutions are designed to meet the individual needs of its clients, from conception to manufacture and after-sales service. We specialize in environmentally friendly systems that are engineered to perform in the most complex sea environments and comply with the highest international standards. Through our innovative, teamoriented approach, BRONSWERK delivers HVAC-R solutions in a timely manner and at a competitive price. BRONSWERK is an accredited ISO 9001 organization. O N B O A R D C L I M A T E E N G I N E E R I N G

Knowledge for optimal efficiency

Knowledge for optimal efficiency Engineering Onboard Climate Control Knowledge for optimal efficiency MARINE HVAC-R MARINE HVAC-R ADVANTAGES 2 KNOWLEDGE FOR OPTIMAL EFFICIENCY The BRONSWERK Advantage It s like the ideal day at sea when

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN products > Energy & Cost Saving Products OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration HVAC energy & COST SAVING POSSIBILITIES A

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok. 44969-09 Sag 09/1437

Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok. 44969-09 Sag 09/1437 technical standards Offshore Substation HVAC System ETS-09 Rev. 2 Dok. 44969-09 Sag 09/1437 Revision survey Document title HVAC System Document no. 44972-09 Target group Fabrications Contractors and Designer

More information

Mechanical Rooftop Custom Capabilities

Mechanical Rooftop Custom Capabilities Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY About HDT Nordic HDT Global, in business for over 75 years, acquired Nordic Air in 2010. Nordic was founded

More information

Defining Quality. Building Comfort. Heating and Cooling Coils

Defining Quality. Building Comfort. Heating and Cooling Coils Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.

More information

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget A PRIMER Educational HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget Contents: Introduction: The best HVAC system is durable, reliable

More information

How To Understand Evaporator

How To Understand Evaporator SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com Why Daikin? Daikin: The Premium Brand industry leader Daikin is recognized as the world s number one leader in the manufacture of HVAC equipment and refrigerants. For over 90 years, Daikin has grown consistently

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Drives and motors. A guide to using variable-speed drives and motors in retail environments Drives and motors A guide to using variable-speed drives and motors in retail environments Improving energy efficiency and lowering the carbon footprint Retailers across the UK take their corporate responsibility

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...

More information

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction

More information

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences

More information

Commercial Portable Air Conditioners

Commercial Portable Air Conditioners Commercial Portable Air Conditioners Air Rover commercial portable air conditioners provide the environmental stability and comfort required by today s sensitive equipment, allowing your business to avoid

More information

"I'm a Daikin Comfort Pro"

I'm a Daikin Comfort Pro www.daikincomfort.com "I'm a Daikin Comfort Pro" Those five simple words can offer you comfort like you ve never experienced. The words mean that the dealer you invited into your home is a highlyqualified

More information

DX14SA AIR CONDITIONER ENERGY-EFFICIENT UP TO 15 SEER SINGLE SPEED COMFORT FOR LIFE

DX14SA AIR CONDITIONER ENERGY-EFFICIENT UP TO 15 SEER SINGLE SPEED COMFORT FOR LIFE DX14SA AIR CONDITIONER ENERGY-EFFICIENT UP TO 15 SEER SINGLE SPEED COMFORT FOR LIFE AIR CONDITIONER ENERGY-EFFICIENT, SINGLE SPEED DX14SA UP TO 15 SEER Comfort for Life Daikin is a global leader for indoor

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

Using Portable Spot Air Conditioners in Industrial Applications

Using Portable Spot Air Conditioners in Industrial Applications Using Portable Spot Air Conditioners in Industrial Applications Cooling People, Processes and Equipment In today s highly competitive manufacturing sector, companies are constantly looking for new ways

More information

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay Original HVAC Units: Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue Photo Essay One fan motor draws air from the lower section of the unit,

More information

marine refrigeration and air conditioning

marine refrigeration and air conditioning marine refrigeration and air conditioning Our History Headquarters Shipbuilding Industry Research & Development Certificates & quality advantages Production Department Refrigeration & A/C Units Chillers

More information

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

CONTROL STRATEGIES FOR HVAC SYSTEMS

CONTROL STRATEGIES FOR HVAC SYSTEMS CONROL SRAEGIES FOR HVAC SYSEMS ZBIGNIEW POPIOLEK Department of Heating, Ventilation and Dust Removal echnology Silesian University of echnology, Poland 1 Definition of control: to apply a regulating influence

More information

COMMISSIONING OF HVAC SYSTEMS

COMMISSIONING OF HVAC SYSTEMS FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS

More information

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates

More information

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you! CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS Air / Water / DX Cooled Cabinet Solutions Mini Data Centre All in One Solution: Where there is a requirement for standalone computing and communications, or highly

More information

HEATING, VENTILATION & AIR CONDITIONING

HEATING, VENTILATION & AIR CONDITIONING HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating

More information

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise A White Paper from the Experts in Business-Critical Continuity Executive Summary Today s data centers are changing rapidly,

More information

HVAC Design Requirements

HVAC Design Requirements Maintenance of HVAC HVAC Design Requirements Air Flow Diagram แบบ Recirculation Air Flow Diagram แบบ Once Through Definition Of Conditions As built At rest In operation air air air Maintenance GMP Requirements

More information

Data Centres A complete solution to noise control and acoustic packages

Data Centres A complete solution to noise control and acoustic packages Data Centres A complete solution to noise control and acoustic packages Introduction World class noise control. Expertise you can trust. IAC Acoustics is world-renowned for providing cost effective solutions

More information

Building Energy Systems. - HVAC: Heating, Distribution -

Building Energy Systems. - HVAC: Heating, Distribution - * Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center

More information

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...

More information

ASTACEA4 Inspect complex/central air conditioning systems

ASTACEA4 Inspect complex/central air conditioning systems Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air

More information

Flameproof HVAC. Stolway. www.stolway.com.au

Flameproof HVAC. Stolway. www.stolway.com.au Flameproof HVAC Stolway www.stolway.com.au Company Overview Stolway provides custom engineered Explosion-Proof Heating, Ventilation and Air Conditioning (Ex HVAC) equipment to the oil, gas and downstream

More information

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages Objectives Increase awareness of the types of economizers currently used for data centers Provide designers/owners with an overview of the benefits and challenges associated with each type Outline some

More information

Commissioning - Construction Documents (Page 1 of 6)

Commissioning - Construction Documents (Page 1 of 6) Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem

More information

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM TOGETHERWESAVE.COM IS IT TIME TO REPLACE YOUR HVAC SYSTEM? If your heating and cooling system is 15 to 20 years old and is experiencing problems,

More information

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Refrigeration and air-conditioning. Alfa Laval s offering at a glance Refrigeration and air-conditioning Alfa Laval s offering at a glance At Alfa Laval green is cool Alfa Laval products are also installed on oil platforms, in power plants, onboard ships, in the mechanical

More information

Energy Efficiency in Industrial HVAC Systems

Energy Efficiency in Industrial HVAC Systems Energy Efficiency in Industrial HVAC Systems Heating, ventilation and air conditioning (HVAC) constitutes up to 35 percent of energy used in manufacturing facilities. This fact sheet is geared towards

More information

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) The power behind the data Private and public businesses, from banks to

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

AIR COOLED CHILLER CHILLED WATER PUMP CONTROL: The chilled water pump with the lowest runtime will automatically start when the outside air temperature rises above the system enable setpoint. When the

More information

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

Selection Tips For Air-Conditioning Cooling Systems

Selection Tips For Air-Conditioning Cooling Systems PDHonline Course M117 (2 PDH) Selection Tips For -Conditioning Cooling Systems Instructor: A. Bhatia, B.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088

More information

HVAC Checklist - Long Form

HVAC Checklist - Long Form HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas

More information

State of the Art Energy Efficient Data Centre Air Conditioning

State of the Art Energy Efficient Data Centre Air Conditioning - White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

HVAC and pressurization. IECEx and ATEX

HVAC and pressurization. IECEx and ATEX HVAC and pressurization IECEx and ATEX Heating Ventilation & Air Conditioners Starting in the 1950s air conditioners have become standard features in residential and industrial applications. Although explosion

More information

6 MECHANICAL HVAC SYSTEMS

6 MECHANICAL HVAC SYSTEMS Conventional Facilities Chapter 6: HVAC Systems 6-1 6 MECHANICAL HVAC SYSTEMS 6.1 Design Criteria 6.1.1 Codes and Standards The latest edition of the codes, standards, orders, and guides referred to in

More information

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Example Retrocommissioning Measure: Opening Throttled Discharge Valves Opening Throttled Discharge Valves This 21-story building, constructed in 1997, is located in Oregon and contains 589,000 gross square feet of mostly office occupancy. The HVAC system includes six large

More information

Construction Services. Furnishing Energy Solutions

Construction Services. Furnishing Energy Solutions Construction Services Furnishing Energy Solutions Construction Services Your Complete Balance-of-Plant Solution Provider Single-point responsibility allows Construction Services to manage your entire project

More information

MUELLER FALLING FILM CHILLERS

MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade

More information

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA.

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA. 1. There is verbiage in the hazardous material report referring to a state licensed abatement contractor. Within the recommendations part of the report (page 64 of 111 of the specification pdf) is the

More information

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

PFT Two stage axial fan The high pressure fan for modern boiler plants

PFT Two stage axial fan The high pressure fan for modern boiler plants PFT Two stage axial fan The high pressure fan for modern boiler plants Modern boilers equipped with complete flue-gas cleaning systems demand fans for high pressure that can be controlled quickly and accurately

More information

10 tips for getting more reliability from your air-conditioning system [reliability]

10 tips for getting more reliability from your air-conditioning system [reliability] 10 tips for getting more reliability from your air-conditioning system [reliability] A guide for installers, specifiers, contractors and architects February 2010 10 tips for getting more reliability from

More information

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

POLICY BULLETIN Tecumseh Compressor Company Compressor Group to Bulk Milk Coolers and Other System Page 1 of 5 Overall reliability can be enhanced if there exists a complete understanding of the features, system design, installation requirements, processing, charging

More information

lindab we simplify construction Air Handling Units Product Overview

lindab we simplify construction Air Handling Units Product Overview Air Handling Units Product Overview Modular Air Handling Units Over 40 years of experience in manufacturing modular air handling units and numerous custom-made solutions for demanding projects worldwide

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Maintenance for Energy Efficiency

Maintenance for Energy Efficiency Maintenance for Energy Efficiency Institute of Hospital Engineering, Australia (IHEA) Seminar Asset Management & Energy Efficiency Exclusive Trane distributor Australia/New Zealand. The TRANE trade mark

More information

PMI-IF-H High Efficiency Gas Heat Units

PMI-IF-H High Efficiency Gas Heat Units PMI-IF-H High Efficiency Gas Heat Units Mechanical High Efficiency Gas Fired Make-Up Air Units Price s new line of high efficiency indirect fired gas heating products are designed to meet the goals of

More information

OASIS PRODUCT GUIDE. Data Centre Cooling INDIRECT EVAPORATIVE COOLER. Data Centres. Telecoms. EPX technology. Class leading performance

OASIS PRODUCT GUIDE. Data Centre Cooling INDIRECT EVAPORATIVE COOLER. Data Centres. Telecoms. EPX technology. Class leading performance OASIS PRODUCT GUIDE Data Centres Telecoms EPX technology Class leading performance Fully configurable solutions INDIRECT EVAPORATIVE COOLER Data Centre Cooling 2 MUNTERS.COM/DATACENTRES Critical cooling

More information

Saving energy in your business

Saving energy in your business Tips & Checklist: Saving energy in your business Whenever you save energy within your business you are also saving money. Electricity costs contribute to your business's financial bottom line so the more

More information

1.2 Refrigerant Equipment. General

1.2 Refrigerant Equipment. General Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying heating, ventilation and air conditioning (HVAC) work. These standards are not intended to restrict or

More information

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System TECHNICAL SPECIFICATION StirLIN-1 Economy Liquid Nitrogen System Reference 80 8120_01 Issue Date August 1, 2015 1. INTRODUCTION Since more than sixty years Stirling Cryogenics has designed and manufactured

More information

Drives and motors. A guide to using variable-speed drives and motors in data centres

Drives and motors. A guide to using variable-speed drives and motors in data centres Drives motors A guide to using variable-speed drives motors in data centres The power behind the data Private public businesses, from banks to supermarkets, to telecommunications companies internet providers

More information

SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK

SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK 1 GENERAL 1.1 GENERAL REQUIREMENTS A. This Section is coordinated with and complementary to the General Conditions and Supplementary General Conditions

More information

NSN 4120-01-21 4-3692

NSN 4120-01-21 4-3692 *TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21

More information

Facilities Maintenance Standards rev 9-1-2015

Facilities Maintenance Standards rev 9-1-2015 Facilities Maintenance Standards rev 9-1-2015 Purpose The purpose of these standards is to outline the minimum requirements for maintaining state owned facilities and infrastructures in a manner that will

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

Are these noise cancelling devices needed to make your chiller quiet??

Are these noise cancelling devices needed to make your chiller quiet?? Are these noise cancelling devices needed to make your chiller quiet?? Not on this chiller! Some sound barriers should never be broken. Government authorities recommend that exposure to loud noise over

More information

Innovent LASER Packaged Fresh Air Conditioning Units

Innovent LASER Packaged Fresh Air Conditioning Units LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent

More information

Glossary of HVAC Terms

Glossary of HVAC Terms Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other

More information

Heat exchangers & coolers for industrial applications

Heat exchangers & coolers for industrial applications Heat exchangers & coolers for industrial applications Tailor-made cooling for all power generation processes. Luvata: power in good hands. A trusted partner Luvata is a leading manufacturer of coolers

More information