Project Carna Concept Review

Size: px
Start display at page:

Download "Project Carna Concept Review"

Transcription

1 Project Carna Concept Review Team Carna [P825] View Project Summary 1

2 CARNA Customer Needs 2

3 CARNA Target Specifications 3

4 [WET] CARNA System Diagram [DRY] Junct. Box Electrical Conduit Junct. Box MUX DAQ Control Mock Circulation Loops Sensors/ Actuators Control x1 Barrier Out to Dry Systems LUI Health Monitor Data Center Tank Sensors/ Actuators Power Plant Wet Dock 4

5 Ten vs. One Single Large Tank with Ten Modular Loops Ten Small Modular Tanks and Loop Design Cost Reliability Complexity Redundant Total

6 One Tank System Single Tank with Ten Mock Loop Modules Tanks Cost Machine Corrosive Total Plastic Composite Double Walled - + Metal

7 Loop Redundancy and Modular Sensor Replacement Modular Sensor Bricks with Bypass Redundancy 7

8 Tank System and Modular Loop 8

9 Heat, Cooling, and Disinfection Heat Power Cost Ease of Implementation Total Immersion Heater Tankless Heater Heat Pump - -1 Computer Waste Heat Cooling Power Cost Ease of Implementation Response Time Control Total Heat Tubes Air Heat Ex Water Hat Ex - + Heat Pup Refrigerant Convection Saline in Cues Disinfection Power Cost Ease of Implementation Maintain Effect Total UV-C Chlorine Generator Chlorine/Bleach Disinfect Tubes Filter Do Nothing Sucker Fish

10 Transducers Level Sensors Power Cost Ease of Implementation Maintain Effect Response Time Total Electro-Optic Continuous Level Infrared Floating Mechanical Device Flow Sensors Power Cost Ease of Implementation Maintain Effect Response Time Total Boolean Volumetric Combination with Temp Pressure Sensors Power Cost Ease of Implementation Maintain Effect Response Time Total Pressure Transmitter Pressure Sensor Pressure Sensor with Display Pressure Transducer Salinity Sensors Power Cost Ease of Implementation Maintain Effect Response Time Total Probe Refractometer Temperature Sensors Power Cost Ease of Implementation Maintain Effect Response Time Total Combination with Pressure Thermocouple Probes Basic Thermocouple Thermistor

11 Heat Transfer through Pipe 11

12 Heat Transfer through Pipe Heat Transfer Through Pipe [Excel] 12

13 Tank Head Loss Pressure loss, tank to pump Head (in) Flow Rate (L/min) Pipe Dia (in) Head Loss Analysis [Excel] 13

14 Heat Transfer of Tank Tank Template [Excel] 14

15 Flow and Pressure Control What is needed? Pressure control at the inlet and outlet of the LVAD What are the specs? Inlet: -2 to 5 mmhg (-.39 to.97 psi) Outlet: to 15 mmhg ( to 2.9 psi) What are the options? Valve/Restrict. Type Power Req d $ Variability (x2) size Total Ball Throttle + - Solenoid Needle Orifice/Restrictor Pinch Gate

16 Flow and Pressure Control Valve Control Power $ Ease of Integration Ease of Use Precision Consistency Step Size Total Manual Pneumatic Actuation Electric Actuation -Separate -Packaged What is the proposed solution? Integrate a ball valve before and after the LVAD, to be controlled by DC servo motors. A worm drive will also be implemented, and a sensor to aid in validating the valve position. LVAD Flow From Tank Flow Control Diagram 16

17 Flow and Pressure Control Ball Valves: Easy to operate Can maintain & regulate flow High volume High temp High pressure Corrosion resistance (Brass/Bronze) Full Port (Unrestricted Flow) Flow through the valve = valve pipe size Ball Valve Schematic (mcmastercarr.com) 17

18 Flow and Pressure Control Worm Drives: Increased torque at a decreased speed Ideal for small electric motors (high-speed/low-torque) Can be self-locking (non reversible direction of transmission) Worm Drive System (mcmastercarr.com) How will it be implemented? The handle of the ball valve will be removed and the stem of the valve will be integrated into a worm drive system, powered by the electric motor. There will be a sensor (to be determined) put into place in order to validate the valve position. 18

19 CARNA [Dry]: Parallel redundant PCs 1BaseT Internal Network DAQ 1 (PC) Breakout Box DAQ 2 (PC) Breakout Box Health Network Control Network Data Management Center LUI Health Network Multiplexer Multiplexer Health Monitor 19 System Signals Line from [Wet] CARNA and Pumps

20 DAQ and Wiring DAQ Cost Ease of Implementation Reliability Power Scalable Total Redundant PCs, non-multiplexed Redundant PCs, multiplexed NI embedded Custom Hardware Test Equipment (oscilloscopes) Redundant NI embedded Wiring Cost Form Factor Noise Rejection Total Single Strand + - Twisted Pair Coaxial

21 Health Monitor Phone on A Chip Cellular Network MCU Health Network Function: Communicate with main subsystems. Get health status. Periodically ship data to the Server for long-term storage. The ability to voice-call/sms and through cellular network. Health Monitor Platform Cost Ease of Implementation Reliability Power Total Microcontroller PC External Communication Cost Ease of Implementation Reliability Power Total VOIP Phone on a chip + 1 TCP/IP/SMTP + - Health Network Protocol Cost Ease of Implementation Reliability Power Total CAN bus + 1 I2C + - RS Monitoring Approach Cost Ease of Implementation Reliability Power Total Polling ADC

22 Health Monitor Network RS232 Design Concept Loop 1 Controller Loop 2 Controller Loop 3 Controller TX RX TX RX TX RX 4 RX TX Health Monitor Digital I/O 4 TX RX Loop 4 Controller TX RX DAQ 2 Line drivers/level shifters are omitted from the diagram. 22

23 Power Plant (Single Fault Tolerant Switch) main power auxiliary power A.T.S. (Automatic Transition Switch) Quality Surge Suppression Manuel by-pass Energy Storage 1 Energy Storage 2 Create requested output voltages Create requested output voltages Fault Tolerant Switching V 1A V 1B V 1A V 1B Manuel by-pass V AC,1 V AC,2 Off the shelf UPS 23

24 Power Plant Off the Shelf Industrial Supply Concept Main Aux Auto Transfer Switch Surge Suppression DC Power Supply Battery Backup Module Redundancy Module Batteries DC DC Power Supply Battery Backup Module Redundancy Module Batteries UPS AC1 UPS AC2 24

25 Power Plant Power Plant Cost Ease of Implementation Reliability Maintanence Total Industrial DC supplies Benchtop DC supplies + 1 Lead acid batteries Li-Ion Batteries - + Flywheel Off-the-shelf UPS Diode paralleling + 1 Fault tolerant switching

26 Data Management Center DAQ 1 DAQ 2 Internal Network Switch 1/1/1 Base-T Who is Master DAQ? Loop and Tank Parameters Accessible From LUI LUI Send Master Data Only?? Organize Data Linux OS WEB Server SFTP SMTP Firewall World-Access Control Network RS232 Redundant Storage Array SSH Health Network RS232 26

27 Data Management Center Data Storage Manager Cost Ease of Implementation Reliability Power Total PC + + Embedded + -1 Operating System Cost Ease of Implementation Reliability Power Total Linux Windows _ + _ -1 Labview RT OS _ + Storage Medium Cost Ease of Implementation Reliability Power Total IDE SATA + 1 Solid State _ Punch Cards + _ + 1 LUI Cost Ease of Implementation Reliability Power Total Touchscreen Keyboard/mouse/monitor LUI Platform Cost Ease of Implementation Reliability Power Total Embedded + -1 PC + + _ 1 27

28 Flow Loop Controller AI Temperature X4 AI Pressure X4 AI Flow Rate X4 MCU w/ ADC, PWMout, And 2 Serial Ports Digital Output X1 [Shut off Valves] PWM Output X4 [Actuators] Health Network Control Network Loop Controller Cost Ease of Implementation Reliability Power Total Single Controller (control all ten loops) One per loop + 1 Two per loop Parallel Redundant + 1 Platform Cost Ease of Implementation Reliability Power Total PC Embedded

29 Parallel Redundant Flow Loop Controllers All input signals will be shared between the two MCU s. They will handshake With each other and with the Health Monitor. Only one MCU will be allowed to actuate the System at any given moment. The other will remain in sleep mode Until it is required to function. (i.e. if the first MCU fails). Handshaking MCU w/ ADC, PWMout, And 3 Serial Ports MCU w/ ADC, PWMout, And 3 Serial Ports Health Network Control Network Health Network Control Network 29

30 Pump Simulator HE 1 HE 2 HE 3 Differenced HE 1 HE 4 Differenced HE 2 LVADR2-Simulator (Microcontroller or PC NI/Labview) HE 5 HE 6 HE 7 HE 8 AMB 1 DAC Array Differenced HE 3 Differenced HE 4 AMB 1 AMB 2 AMB 2 Motor Speed Motor Speed CARNA GRND 5V Digital Signals Analog Voltages 3

31 Local User Interface Six Principles of Heuristic Evaluation PRINCIPLES (Offers more specific direction than the more general set of rules when it comes to problem resolution) 1. Visibility Keeping all needed options and materials for a given task visible without distracting the user with extraneous or redundant information 2. Feedback Keeping users informed of actions or interpretations, changes of state or condition, and errors or exceptions that are relevant and of interest to the user through clear, concise and unambiguous language familiar to users 3. Structure Organize the user interface purposefully, in meaningful and useful ways based on clear, consistent models that are apparent and recognizable to users. 31

32 Local User Interface Six Principles of Heuristic Evaluation (Cont.) 4. Reuse Systems should use language and structure in a consistent fashion Identical terminology should be used for - Prompts - Menu - Help screens 5. Tolerance Reducing the cost of mistakes and misuse by allowing, undoing and redoing while also preventing errors 6. Simplicity Make simple, common tasks simple to do, communicating clearly and simply in the users own language 32

33 Local User Interface Start Panel 33

34 Local User Interface 34

35 Local User Interface 35

36 Local User Interface 36

37 Local User Interface 37

38 Local User Interface 38

39 Local User Interface 39

40 Local User Interface Emergency Situations In Emergency Situations, the User Interface screen will go RED (also a auditory alert sound of 4-7 dba) and immediately goes to the maintenance program with a full and complete description of the problem. Secondary system will also activate when the emergency situation arises until the maintenance engineer arrives and deals with the problem. The maintenance engineer will have immediate access to all of the UI and have an full and descriptive procedure on screen to fix the problem. 4

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

Measuring Temperature withthermistors a Tutorial David Potter

Measuring Temperature withthermistors a Tutorial David Potter NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

NETWORK ENABLED EQUIPMENT MONITOR

NETWORK ENABLED EQUIPMENT MONITOR NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone

More information

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits) Page 1 of 6 (Home) Symbols / Visit us on: Fluid Power, Automation and Motion Control for all Industries About Us Products Services Catalogs Place an Order Training & Information Contact Us Employee Access

More information

Degree programme in Automation Engineering

Degree programme in Automation Engineering Degree programme in Automation Engineering Course descriptions of the courses for exchange students, 2014-2015 Autumn 2014 21727630 Application Programming Students know the basis of systems application

More information

FUNDAMENTALS OF CONTROL ENGINEERING

FUNDAMENTALS OF CONTROL ENGINEERING EQUIPMENT FOR ENGINEERING EDUCATION EQUIPMENT FOR ENGINEERING EDUCATION ENGINEERING MECHANICS & MACHINE ELEMENTS Statics Strength of Materials Dynamics Fundamentals of Engineering Design Machinery Diagnosis

More information

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3 Section 5.1 Electrical Systems - IQAN Digital Control System IQAN Control System Components........................... 5.1.3 IQAN Operational Description: At Machine Startup.....................................

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Overheating limit control

Overheating limit control Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Measuring, Controlling and Regulating with labworldsoft

Measuring, Controlling and Regulating with labworldsoft Kai-Oliver Linde IKA-Werke Staufen Neumagenstraße 27 79219 Staufen Measuring, Controlling and Regulating with labworldsoft Rapid and easy networking of lab devices from different manufacturers The user

More information

NGSS Data Consolidator (DC)

NGSS Data Consolidator (DC) NGSS Data Consolidator (DC) The Data Consolidator (DC) facilitates system configuration, monitors network status, and supervises long-term data storage and remote data transmission. The DC consists of

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

Microcontroller to Sensor Interfacing Techniques

Microcontroller to Sensor Interfacing Techniques to Sensor Interfacing Techniques Document Revision: 1.01 Date: 3rd February, 2006 16301 Blue Ridge Road, Missouri City, Texas 77489 Telephone: 1-713-283-9970 Fax: 1-281-416-2806 E-mail: [email protected]

More information

TAC I/NETTM MR-AHU-HP. Application Specific Controller

TAC I/NETTM MR-AHU-HP. Application Specific Controller TAC I/NETTM MR-AHU-HP Both the MR-AHU and MR-HP controllers are application specific controllers (ASCs). The intention of the design is to reduce total install cost through pre-engineered control algorithms

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

Data Center Commissioning: What you need to know

Data Center Commissioning: What you need to know Data Center Commissioning: What you need to know Course # CXENERGY1511 AIA Provider # 50111116 AABC Commissioning Group CxEnergy Conference Henderson, NV April 30, 2015 Presented by: Judson H. Adams, P.E.,

More information

TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller

TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller Intuitive control TLC 700 The multifunctional controller TLC 700 The intelligent controller for complex systems TEDDINGTON As easy as Teddington air curtain systems are the ultimate when it comes to the

More information

Quanser NI-ELVIS Trainer (QNET) Series: QNET HVAC. Heating, Ventilation, and Air Conditioning (HVAC) User Manual. User Manual

Quanser NI-ELVIS Trainer (QNET) Series: QNET HVAC. Heating, Ventilation, and Air Conditioning (HVAC) User Manual. User Manual Quanser NI-ELVIS Trainer (QNET) Series: QNET HVAC Heating, Ventilation, and Air Conditioning (HVAC) User Manual User Manual Table of Contents 1. Introduction...1 2. Requirements...1 3. References...1 4.

More information

PROCEDURES FOR SELF DIAGNOSTICS

PROCEDURES FOR SELF DIAGNOSTICS PROCEDURES FOR SELF DIAGNOSTICS Baum Tools Unlimited Inc. March 31, 1999 TAU 2.1 READING ACTUAL VALUES 1. Remove the operating console from the TAU 2. At the upper side of the operating consol there is

More information

... Electronic Softstarter...

... Electronic Softstarter... . CT-START Electronic Softstarter. 6 A. to 900. A......... CT START CT-START is a multi-function electronic system with a microcontroller and thyristors, designed for use with all 3-phase squirrel cage

More information

Simplify Data Acquisition with a Built-in LXI Web Server

Simplify Data Acquisition with a Built-in LXI Web Server M E A S U R E M E N T T I P S Volume 9, Number 3 Simplify Data Acquisition with a Built-in LXI Web Server Snapshot: Make temperature measurements quickly and easily There are many applications in which

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM Page 1 of 19 Cat Electronic Technician 2015A v1.0 Product Status Report 2:49 PM Product Status Report Parameter Value Product ID WRK00337 Equipment ID WRK00337 Comments A01-52 C9 330D (THX37891) Parameter

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting Sequence of Operations 1 Power supply and field wiring block 2 Energy Cut Off (ECO) 3 Water flow plunger and cold inlet 4 Magnetic flow switch 5 Water temperature thermistor 6 Control panel and circuit

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

Design of an Insulin Pump. Purpose of an Insulin Pump:

Design of an Insulin Pump. Purpose of an Insulin Pump: Design of an Insulin Pump Purpose of an Insulin Pump: Insulin is a hormone central to regulating carbohydrate and fat metabolism in the body. It is secreted regularly within the body and aids in converting

More information

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES

More information

Dyeing Programmer DP - 01

Dyeing Programmer DP - 01 Dyeing Programmer DP - 01 Display and Controls. 1) Display: 16/2 alphanumeric display 2) Temperature range: 0 to 150 degree. 3) Resolution: 1 degree. 4) Accuracy: +/- 1 degree. 5) Temperature control setting:

More information

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems ViewPower User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...2 1.4. Features...2

More information

SingleNet Single Cable Control System

SingleNet Single Cable Control System Single Cable Control System Economical, Reliable and Expandable Two-Wire Single Cable System DRIP/MICRO IRRIGATION PRODUCTS Single Cable Control System System Manager or Irrigation Controller Controls

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

Technical Information POWER PLANT CONTROLLER

Technical Information POWER PLANT CONTROLLER Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for

More information

Basic Technology Series

Basic Technology Series Basic Technology Series Fundamentals of Car Air Conditioning 2007 Air Conditioning #003 The Rear Cooler Construction Fan Fan Filter Figure A : Trunk Figure B : Overhead Dual Air-Conditioner In This Issue

More information

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER Understanding what a PAC is starts from the understanding of PLC. A PLC is a Programmable Logic while

More information

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments The MSITel module family allows your ground console to be everywhere while balloon experiments run everywhere MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

More information

Introduction To SCADA and Telemetry

Introduction To SCADA and Telemetry Introduction To SCADA and Telemetry Joe Mullaney Senior I&C Engineer MSE Technology Applications, Inc. Tetragenics Division [email protected] Overview Definitions What is SCADA? What is Telemetry?

More information

Serial Communications

Serial Communications April 2014 7 Serial Communications Objectives - To be familiar with the USART (RS-232) protocol. - To be able to transfer data from PIC-PC, PC-PIC and PIC-PIC. - To test serial communications with virtual

More information

Wireless Home Security System

Wireless Home Security System Wireless Home Security System Group: D14 Members: Vaibhav Singh (05D07026) Abhishek Tiwari (05D07028) Sauvik Chowdhury (05D07029) 1. Abstract The project is aimed at designing a low cost and reliable wireless

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work. Install Guide CT100 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

DCM. Product Brochure. Diagnostic Communication Master

DCM. Product Brochure. Diagnostic Communication Master DCM Product Brochure Diagnostic Communication Master DCM The DCM Diagnostic Communication Master is the best solution for the control of actuators from a remote control room through a two-wire transmission-mode

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

HMI EMBEDDED SYSTEM DESIGN AS A FUNCTION OF TECU

HMI EMBEDDED SYSTEM DESIGN AS A FUNCTION OF TECU HMI EMBEDDED SYSTEM DESIGN AS A FUNCTION OF TECU Katrenčík J., Čupera J., Fajman M. Department of Technology and Automobile Transport, Faculty of Agronomy, Mendel University in Brno, Zemedelska 1, 613

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

If an occupancy of room is zero, i.e. room is empty then light source will be switched off automatically

If an occupancy of room is zero, i.e. room is empty then light source will be switched off automatically EE389 Electronic Design Lab Project Report, EE Dept, IIT Bombay, Nov 2009 Fully-automated control of lighting and security system of a Room Group No: D2 Bharat Bhushan (06d04026) Sravan

More information

White Paper: Pervasive Power: Integrated Energy Storage for POL Delivery

White Paper: Pervasive Power: Integrated Energy Storage for POL Delivery Pervasive Power: Integrated Energy Storage for POL Delivery Pervasive Power Overview This paper introduces several new concepts for micro-power electronic system design. These concepts are based on the

More information

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1 Fault codes DM1 Industrial engines DC09, DC13, DC16 Marine engines DI09, DI13, DI16 03:10 Issue 5.0 en-gb 1 DM1...3 Abbreviations...3 Fault type identifier...3...4 03:10 Issue 5.0 en-gb 2 DM1 DM1 Fault

More information

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace. SAFETY Industrial DESCRIBE hazards and precautions taken to avoid injury in the workplace. Example #1: All of the following are common PPE used to perform maintenance activities EXCEPT: a. Safety Glasses

More information

Designing an efficient Programmable Logic Controller using Programmable System On Chip

Designing an efficient Programmable Logic Controller using Programmable System On Chip Designing an efficient Programmable Logic Controller using Programmable System On Chip By Raja Narayanasamy, Product Apps Manager Sr, Cypress Semiconductor Corp. A Programmable Logic Controller (PLC) is

More information

Example. Fluid Power. Circuits

Example. Fluid Power. Circuits Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9

More information

SCADA and Monitoring for Solar Energy Plant

SCADA and Monitoring for Solar Energy Plant SCADA and Monitoring for Solar Energy Plant Segment: Industry Country: Thailand Author: Ranon Satitpanyapan Products: NI LabVIEW with LabVIEW Real-Time Module crio Real-Time controller 8 slot with 16 current

More information

KTA-223 Arduino Compatible Relay Controller

KTA-223 Arduino Compatible Relay Controller 8 Relay Outputs 5A 250VAC 4 Opto-Isolated Inputs 5-30VDC 3 Analog Inputs (10 bit) Connections via Pluggable Screw Terminals 0-5V or 0-20mA Analog Inputs, Jumper Selectable 5A Relay Switching Power Indicator

More information

Industrial Steam System Process Control Schemes

Industrial Steam System Process Control Schemes Industrial Steam System Process Control Schemes This paper was developed to provide a basic understanding of the different process control schemes used in a typical steam system. This is however a fundamental

More information

Industrial Bar Code Scanners

Industrial Bar Code Scanners DS4800 Industrial Bar Code Scanners Enhanced Connectivity Ease of use Configuration SW Tool ACR4 technology Smart focus adjustment APPLICATIONS Automated warehousing Reading on pallets Picking systems

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

Fossil fuel heating equipment

Fossil fuel heating equipment Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09 0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by

More information

Implementing a Reliable Furnace Monitoring System

Implementing a Reliable Furnace Monitoring System Category: Manufacturing Implementing a Reliable Furnace Monitoring System Products Used: RT Series PXI (PXI 1002 And PXI 8156B) LabVIEW Real-Time by V. Arunachalam Sr. Project Engineer Anand Chinnaswamy

More information

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar INTRODUCTION Cathodic Protection is an electrochemical

More information

Electronic Power Control

Electronic Power Control Service. Self-Study Programme 210 Electronic Power Control Design and Function With the Electronic Power Control system, the throttle valve is actuated only by an electric motor. This eliminates the need

More information

Executive Summary. Technical Description

Executive Summary. Technical Description Executive Summary The Cellwatch system is built using modules. The majority of the system is constructed with Data Collection Modules (DCMs). The DCMs are optically linked to Control Units (CUs) that in

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

www.curtisinstruments.com

www.curtisinstruments.com CANBUS I/O EXPANSION MODULE MODELS 56 / 56P FEATURES Eighteen multi-purpose I/O pins provide simple, flexible vehicle control system expansion. Two high-frequency (A, A) PWM driver outputs support a variety

More information

SECURITY SYSTEM IN INDUSTRIES USING ZIGBEE TECHNOLOGY

SECURITY SYSTEM IN INDUSTRIES USING ZIGBEE TECHNOLOGY SECURITY SYSTEM IN INDUSTRIES USING ZIGBEE TECHNOLOGY 1 S. Ashmad, 2 M.Mohan Babu, 3 P. Sudheer Asst. Professor, Department of E.I.E, SITAMS, Affiliated to JNTUA University, Chittoor, A.P Email : [email protected],

More information

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

Dealer Sales & Service Guide

Dealer Sales & Service Guide Analog Models w/thermostat or Timerstat Heat Siphon Not Starting 1 BREAKER TRIPPED - Check Breaker Box for correct size breaker Breakers: EX; Domestic model 2.25hp (20amp) 3.25hp (40amp) 5hp (50amp) check

More information

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application Marwa M. Abdulmoneim 1, Magdy A. S. Aboelela 2, Hassen T. Dorrah 3 1 Master Degree Student, Cairo University, Faculty

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

HEAT SIPHON ANSWERBOOK

HEAT SIPHON ANSWERBOOK ERROR CODES -Displayed on Player Board There are three different types of error codes displayed by the Digital Player Controller" 1 WARNING CODE - The Warning Code is displayed for the duration the error

More information

Introduction to Process Control Actuators

Introduction to Process Control Actuators 1 Introduction to Process Control Actuators Actuators are the final elements in a control system. They receive a low power command signal and energy input to amplify the command signal as appropriate to

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and

More information

Partner for automation Water technology

Partner for automation Water technology Partner for automation Water technology Your objective: Economy in plant engineering and plant lifecycle management Energy prices today are high and rising even further, forcing you as municipal or industrial

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction Reverse Osmosis Parts Introduction Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2 Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W)

More information

How to design an insulin pump

How to design an insulin pump How to design an insulin pump Learn about the purpose of an insulin pump, its overall workings, and the requirements needed for its design as well as implementation. By Asha Ganesan Applications Engineer

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

I2C PRESSURE MONITORING THROUGH USB PROTOCOL. I2C PRESSURE MONITORING THROUGH USB PROTOCOL. Product Details: To eradicate human error while taking readings such as upper precision or lower precision Embedded with JAVA Application: Technology Used:

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

Thermostat Application Module Kit

Thermostat Application Module Kit Thermostat Application Module Kit PUG0040-00 Product User Guide Kit Contents Overview Thermostat Application Module CD-ROM: Software Examples and Documentation The Thermostat Application Module provides

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

Carlo Canziani Business Development EMEA. 2012 Agilent Technologies

Carlo Canziani Business Development EMEA. 2012 Agilent Technologies Ottimizzare il tempo di operatività delle batterie nei dispositivi wireless New Innovation Dramatically Improves Battery Current Drain Measurement Accuracy Carlo Canziani Business Development EMEA 1 Wireless

More information

High Power Programmable DC Power Supplies PVS Series

High Power Programmable DC Power Supplies PVS Series Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient

More information

FILLING AND PURGING THE SYSTEM

FILLING AND PURGING THE SYSTEM FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation

More information

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling for Simultaneous Heating and Cooling F. Sustainable Energy Centre, University of South Australia Mawson Lakes Boulevard, Mawson Lakes 5095 AUSTRALIA E-mail: [email protected] Abstract The high efficiency

More information

Safety Requirements Specification Guideline

Safety Requirements Specification Guideline Safety Requirements Specification Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:[email protected] -1- Summary Safety Requirement

More information