2015 Fire Alarm Systems Product catalogue
|
|
|
- Godwin Bennett
- 10 years ago
- Views:
Transcription
1 2015 Fire Alarm Systems Product catalogue
2
3 Table of contents 2015 Fire Alarm Systems Company Profile Addressable Fire Alarm Systems Addressable Fire Alarm Panels IRIS Addressable Fire Alarm Panel SIMPO Addressable Fire Alarm Panel IRIS/SIMPO Repeater Panel SesnoIRIS Addressable Fire Alarm Detectors: T110 S130 M140 B124 SensoIRIS Addressable Fire Alarm Modules: MCP150 MIO MC-Z MOUT MOUT SensoIRIS Addressable Fire Alarm Modules: MC - D MISO MINP Programmer SensoIRIS Addressable Fire Alarm Sirens: WSOU WSST BSOU BSST Conventional Fire Alarm Systems MAG Series Conventional Fire Alarm Panels MAG Series Conventional Fire Alarm Panels: MAG2 MAG4 MAG Series Conventional Fire Alarm Panels: MAG8 MAG8Plus ME4 MS4 MR8 ML SensoMAG Series Conventional Fire Alarm Detectors: F10 R20 S30 M40 SensoMAG Series Conventional Fire Alarm Detectors: MCP 50 B24 B24D B24RD B12 Conventional Fire Alarm Sirens: SF100 SF105 SF110 SF200 SF300 Accessories: FRL-1 DB Plastic Cover Set FLM Kit PS2410 Beam Detector ProsTE Programming Software Observer Monitoring Software
4 Teletek Electronics JSC is a high-tech manufacturer of a full range of intruder and fire alarm systems Teletek Electronics is a Subsidiary of Teletek Group Holding, Bulgaria. Today, 24 years after the establishment of Teletek Electronics JSC, we continue to create, research and realize new ideas for better intruder and fire security products. In order to meet our clients contemporary and growing needs, we started researching and introducing not just separate products, but complete security and fire alarm system solutions, suitable for large range of applications - residential homes and small offices, houses, country houses, medium to large trade and office buildings (including storehouses, supermarkets, etc). On the basis of the reliable client feedback we continue improving the quality and features of our product range. We believe in addressing our customers needs no matter how small or big they may be. Teletek Electronics efforts are dedicated to its customers. We are proud we can provide effective Customer Support by facilitating: Requests processed on the day they are received; Help desk for customer technical support; Training - In-house or On site. As recognition for its high quality and reliable production Teletek Electronics is awarded with ISO 9001:2008 Certificate. Teletek Electronics JSC has already established itself as a Company with traditions and reliable solutions in intruder and fire alarm systems - our products are already well known in more than 65 countries all over the world. The heart of Teletek Electronics success is its productive flexibility that is expressed not only in the wide production range but also in the ability to design and make specific and exclusive versions of the product in collaboration with the Customer. This important plus brings about obvious advantages, especially in the area of intruder and fire alarm systems where the possibility to actuate a customized product is sometimes very hard to find. Our company works with 2 hi-tech SMD lines consisting of DEK Ela screen, PHILIPS Topaz-X Pick and Place machines and ERSA Hotflow5 oven. With capability of placing over components per hour, The Pick and Place machines enable our high skilled and motivated engineers to mount fine pitch components, BGA components and micro BGA components as well as Double-sided Reflow Soldering. As of today, over 120 young and highly educated specialists work in the company s 6 departments to ensure a full business cycle from market research and generation of product ideas to the development, production and marketing of the end product. The Marketing and Sales together with Product Management and Technical support teams are the link between the company and its valued customers. As a customer oriented company Teletek Electronics strives to maintain a constant bond with its Clients by trying to respond to their technical and market needs. We have gained valuable experience in making custom made solutions for our top Clients to their specifications and individual preferences. Thousands of installations have been carried out with Teletek s intruder and fire alarm ranges in over 65 countries in the last 24 years. This gives us the confidence that there is no obstacle we cannot overcome together with our Partners. We do believe that our Partners are not just our Customers but also friends. We are successful because of them and we will continue to work successfully together because Teletek Electronics is the security system manufacturer you can rely on! 4
5 Addressable fire Alarm systems
6 IRIS / Simpo Addressable panels IRIS SIMPO Loops Devices per Loop Expansion Loop Types IRIS TTE/ IRIS SS Simpo TTE Galvanic Separation in Loops Built in isolator in Loops Total number of devices per system Zones Multi language display Redundant processor Event Log Day/ Night Mode System Sensor Protocol (IRIS SS Loop) Sounders/ Strobes Synchronization Display 320/240 touch screen 4*40 symbols LCD TCP/ IP (built in) Redundant network (RS 485) (optional) (optional) Battery 1x12V/18Ah 1x12V/18Ah Monitoring of the internal battery resistance Box Metal with plastic cover Metal Software Support ProsTE/ Observer ProsTE Standard EN54-2/4 EN54-2/4 6
7 IRIS Addressable panel Up to 4 loops with up to 250 devices per loop Works with Teletek Electronics and System Sensor communication protocols IRIS is an addressable fire alarm panel with 1 to 4 loops and maximum coverage of 96 zones. Up to 250 devices can be connected to every system loop. The information for the system status is visualized on sensitive graphic display and LED indication for zones and troubles. With special 2 Steps of alarm level working algorithm the false alarms are effectively minimized. The panel has a comprehensive day/night mode facility. The panel supports two communication protocols: Teletek Electronics (IRIS TTE loop) and System Sensor series 200/500 (IRIS SS loop) according to the type of devices used. In the configuration of the IRIS panel, both TTE and SS Loops can be implemented at the same time. Up to 32 IRIS panels can be connected in Ethernet or RS485 redundant network. Direct programming with ProsTE software is available. Loops: 1 to 4 (both TTE and SS loops can be mounted in random configuration) EN54-2/4 Devices per loop: 250 (TTE loop); 198 (SS loop) Zones: 96 Outputs: (monitored, relay type) Outputs (non-monitored, programmable, relay type): Programmable inputs/ outputs: Memory LOG: Panels in Ethernet network (built-in TCP/IP): Panels in RS485 redundant network (optional module): Thermal printer: Display: 4 4, 230V/10A Up to events Up to 32 Up to 32 Optional 320/240 touch screen Technical Specifications Main Power Supply...230VAC +10%/ -15% Frequency... 50/ 60Hz Back-up Power Supply...1 battery, 12V/ 18Ah Electrical output...7,5a Internal resistance of the battery...<0.3 Ohm Operating temperature C to +50 C Weight (without battery)...6kg Dimensions of metal bottom...441x331x80mm Dimensions of front cover...461x344x45mm IRIS TTE Loop Loop Expander for 1 loop TTE protocol Supports SensoIRIS devices Max. consumption of loop devices - 0,5 A Max. number of devices in the loop Multi language support: Programming: (currently available: English, Italian, Portuguese, Russian, Turkish, Polish, Croatian, Dutch, Latvian, French, Bulgarian) ProsTE software Standard: EN54-2/4 IRIS SS Loop Loop Expander for 1 loop System Sensor 200/500 and advanced 200 protocols Supports System Sensor devices Max. consumption of loop devices - 0,5 A Max. number of devices in the loop (99 detectors + 99 devices) IRIS/ SIMPO Redundant module RS485 Network module The maximum length between two modules is 1000m 7
8 SIMPO Addressable panel Up to 2 loops with up to 250 devices per loop Entry level solution for smaller addressable installations Simpo is the perfect solution for smaller addressable installations. It supports operation with up to two loops with coverage of 16 zones. 250 devices with Teletek Electronics protocol could be connected to each loop. System status is visualized via LCD display and LED indication. Up to 32 Simpo panels can be connected in RS485 redundant network or Ethernet network. Direct programming with ProsTE software is available. The panel comes in a metal casing with a multilingual LCD display and front foil for easier customizing. EN54-2/4 Loops: 1 to 2 (TTE protocol) Devices per loop: 250 Zones: 16 Inputs: 3 Outputs: (monitored, relay type) Outputs (non-monitored, programmable, relay type): Memory LOG: Panels in RS485 redundant network (optional module): Thermal printer: Display: Multi language support: Programming: 5 4, 24VDC/10A events Up to 32 Optional 4*40 symbols (currently available: English, Italian, Portuguese, Russian, Turkish, Polish, Croatian, Dutch, Latvian, French, Bulgarian) ProsTE software Technical Specifications Main Power Supply VAC Frequency Hz Back-up Power Supply...1 battery, 12V/ 18Ah Electrical output...4,2a Internal resistance of the battery...<0.3 Ohm Operating temperature C to +50 C Weight (without battery)...4,2kg Dimensions...308x415x78mm Standard: EN54-2/4 8 SIMPO TTE Loop Loop Expander for 1 loop TTE protocol Supports SensoIRIS devices Max. consumption of loop devices - 0,5 A Max. number of devices in the loop IRIS/ SIMPO Redundant module RS485 Network module The maximum length between two modules is 1000m
9 Repeater IRIS/SIMPO REpeater panel The Repeater panel is designed to display the events of the connected in redundant network IRIS and SIMPO addressable fire panels. The Repeater fire alarm panel is designed to work with Teletek Electronics addressable fire alarm panels IRIS and SIMPO. It is used to display the events of the connected to network addressable panels. The connection between Repeater panel and other addressable panels IRIS and/or SIMPO is via redundant network module based on RS485 interface. Maximum number of fire alarm panels in network is 32. Maximum distance between two panels is up to 1000m. The information for events are visualized on LCD display and LED indication for the system status. The Repeater panel has a built-in real time clock. Available micro USB for latest software and firmware updates. EN54-2/4* Protocol type: Panels in RS485 redundant network: Network type: TTE Up to 32 Ring topology Connection wires: mm 2 Max. length between two panels: Memory LOG: Display: Multi language support: 1000m events 4*40 symbols (currently available: English, Italian, Portuguese, Russian, Turkish, Polish, Croatian, Dutch, Latvian, French, Bulgarian) Technical Specifications Main power supply... 24±4 V DC Frequency... 50/ 60Hz Max. consumption A Operating temperature C to +50 C Weight kg Dimensions x330x48mm * The panel complies with the following standards: EN in case the repeater panel is connected to IRIS or SIMPO addressable panels in a redundant network EN in case the repeater is powered on with external power supply unit, which covers this standard Up to 32 panels connected in a redundant network Redundant module IRIS Redundant module IRIS SIMPO Redundant module IRIS/SIMPO REPEATER Ext. power supply unit 24 V DC 9
10 Sensoiris Addressable detectors SensoIRIS T110/ IS Fixed Temperature and Rate of Rise detector Supports Teletek Electronics protocol Class, selectable from the control panel - A1R, A2S, BS Protected area (in accordance with EN54-5) - up 35m² Installation height (in accordance with EN54-5) - up 3.5m Day/Night mode Low profile design LED indication with 360 visibility Available with built in isolator - SensoIRIS T110 IS IP30 EN54-5 EN54-17 SensoIRIS S130/ IS Optical smoke detector Supports Teletek Electronics protocol Sensitivity, selectable from control panel - High/ rmal/ Middle/ Low Protected area (in accordance with EN54-7) - up 120m² Installation height (in accordance with EN54-7). - up 16m Day/Night mode Low profile design LED indication with 360 visibility Available with built in isolator - SensoIRIS S130 IS IP30 EN54-7 EN54-17 SensoIRIS M140/ IS Combined detector Supports Teletek Electronics protocol Class (in accordance with EN54-5) - A1R Sensitivity (in accordance with EN54-7) - High/ rmal/ Middle/ Low Protected area (in accordance with EN54-5,7) - up 120m² Installation height (in accordance with EN54-5,7) - up 16m Day/Night mode Low profile design LED indication with 360 visibility Available with built in isolator - SensoIRIS M140 IS IP30 EN54-5/7 EN54-17 SensoIRIS B124 Compatible with SensoIRIS detectors Wire gauge for terminals - 3mm Material (plastic), color - ABS, white 10
11 Sensoiris Addressable modules SensoIRIS MCP 150 Manual call - point Supports Teletek Electronics protocol Type of the working element - resettable (flexible) Type, according EN A Built in isolator Material (plastic), color - ABS, red Optional protective plastic cover IP40 EN54-11 EN54-17 SensoIRIS MIO EN54-18 Input/output modules EN54-17 Supports Teletek Electronics protocol Placed in plastic box with transparent cover for easy inspection Built in isolator Loop powered Available versions - MIO 22 (2 inputs/2 outputs); MIO 04 (4 outputs); MIO 40 (4 inputs) IP40 SensoIRIS MC-Z Conventional zone module Supports Teletek Electronics protocol EN54-18 Provides interface between a zone of conventional detectors and an addressable IRIS and SIMPO TTE loop expander Placed in plastic box with transparent cover for easy inspection Built in isolator Loop powered IP40 SensoIRIS MOUT EN54-18 Potential output for conventional sounders EN54-17 Supports Teletek Electronics protocol Provides interface between a zone of conventional sirens and an addressable IRIS and SIMPO TTE loop expander Placed in plastic box with transparent cover for easy inspection Built in isolator IP40 SensoIRIS MOUT EN54-18 Electrical mains switching output Supports Teletek Electronics protocol Suitable for control of 240V AC voltage circuits Placed in plastic box with transparent cover for easy inspection Built in isolator Loop powered Available versions: MOUT-240/1 (with 1 relay output); MOUT-240/2 (with 2 relay outputs) IP40 11
12 Sensoiris Addressable modules SensoIRIS MC - D Addressable base for conventional SensoMAG series detectors Allows the use of conventional detectors with Teletek Electronics addressable panels IRIS and SIMPO Supports Teletek Electronics protocol Loop powered EN54-18 SensoIRIS MISO Isolator module Placed in plastic box with cable running holes for easy installation Supports Teletek Electronics protocol IP40 EN54-17 SensoIRIS MINP Mini input module Used for connection of external control devices, gas detection, panic switches, etc Compact size for built in mounting Supports Teletek Electronics protocol EN54-18 SensoIRIS GAS Addressable gas detector TTE protocol Detection of natural gas (methane) and LPG (propane-butane) Alarm level: 10%LEL Sound level: 85dB Alarm output: 12VDC/ up to 200mA Colour - white Standard: GB IP30 SensoIRIS Programmer Programming tool Compatible with SensoIRIS detectors and modules TTE protocol Mobility in operation Multi language support Optional battery power supply 4x1.5V (not included) The kit includes: cables for programming SensoIRIS modules; AC-DC adapter 12
13 Sensoiris Addressable sirens/strobes SensoIRIS WSOU / IS Wall mount sounder Sound - Low level: 92dB; High level: 100dB 32 sound types selectable from the panel TTE protocol Loop synchronization for better alarm signal Loop powered Color - red Available in version with built in isolator (SensoIRIS WSOU IS) IP43C, type B EN54-3 EN54-17 SensoIRIS WS / IS Wall mount sounder and strobe Sound - Low level: 92dB; High level: 100dB 32 sound types selectable from the panel TTE protocol Loop synchronization for better alarm signal Loop powered Color - red, transparent Available in version with built in isolator (SensoIRIS WS IS) IP43C, type B EN54-3 SensoIRIS WSST EN54-23 (VAD)/ IS Wall mount sounder and strobe Sound - Low level: 92dB; High level: 100dB 32 sound types selectable from the panel TTE protocol Loop synchronization for better alarm signal Loop powered Color - white, transparent Available in version with built in isolator (SensoIRIS WSST IS) IP43C, type B Coverage volume: W-2,4-6 SensoIRIS BSOU / IS Base with built in sounder, compatible with SensoIRIS detector series Suitable for wall or ceiling mounting Sound - Low level: 92dB; High level: 100dB 32 sound types selectable from the panel TTE protocol Loop synchronization for better alarm signal Loop powered Color - white Available in version with built in isolator (SensoIRIS BSOU IS) IP21C, type A SensoIRIS BSST / IS Base with built in sounder and strobe, compatible with SensoIRIS detector series Sound - Low level: 92dB; High level: 100dB 32 sound types selectable from the panel TTE protocol Loop synchronization for better alarm signal Loop powered Color - white Available in version with built in isolator (SensoIRIS BSST IS) IP21C, type A EN54-3/ 23 EN54-17 EN54-3 EN54-17 EN54-3 EN
14 Conventional FIRE ALARM Systems
15 MAG Conventional panels MAG2 MAG4 MAG8 MAG8plus Zones Devices Double knock Sounder output Fire relay Fault relay AUX output Sounder delays Instant zone Indication Access protection Plastic box/metal box Zone expander Sounder expander LOG module Relay expander Battery Standard 2 32 per zone* 2 (0,3 A) (0,3 A) LED Key / 1x12V/7Ah EN54-2/ per zone* 2 (0,3 A) (0,3 A) LED Key / 1x12V/7Ah EN54-2/ per zone* 2 (0,5 A) (0,3 A) LED Key / 1x12V/7Ah EN54-2/ per zone* 4 (0,3 A) (0,3 A) LED Key Cover: plastic, Bottom: metal 1x12V/18Ah EN54-2/4 * with SensoMAG detectors 15
16 MAG Conventional panels MAG 2 EN54-2/4 Conventional fire alarm control panel 2 fixed zones Supports up to 32 detectors and call points per zone 2 monitored siren outputs - 0,3 A each Active EOL allowing continuous monitoring of inputs Levels of access protected by means of key programming Multi language front panels Metal or plastic box Main Power Supply...230VAC ± 10% Back-up Power Supply...1 battery, 12V/ 7Ah Main power supply consumption...50ma Auxiliary output...24vdc/ 0.3A fuse Internal resistance of the battery...<0.3 Ohm Operating temperature...-5 C to +40 C Weight (without battery)...2.7kg (m); 2.1kg (p) Dimensions of the metal box...200x290x80mm Dimensions of the plastic box x290x100mm MAG 4 EN54-2/4 Conventional fire alarm control panel 4 fixed zones Supports up to 32 detectors and call points per zone 2 monitored siren outputs - 0,3 A each Active EOL allowing continuous monitoring of inputs Levels of access protected by means of key programming Multi language front panels Metal or plastic box Main Power Supply...230VAC ± 10% Back-up Power Supply...1 battery, 12V/ 7Ah Main power supply consumption...50ma Auxiliary output...24vdc/ 0.3A fuse Internal resistance of the battery...<0.3 Ohm Operating temperature...-5 C to +40 C Weight (without battery)...3.5kg (m); 2.1kg (p) Dimensions of the metal box...320x220x80mm Dimensions of the plastic box...340x290x100mm 16
17 MAG Conventional panels MAG 8 EN54-2/4 Conventional fire alarm control panel 8 fixed zones Supports up to 32 detectors and call points per zone 2 monitored siren outputs - 0,5 A each Double knock mode Siren delay Supports relay expander MR 8 and LOG module ML Active EOL allowing continuous monitoring of inputs Levels of access protected by means of key Simple programming by means of jumpers Multi language front panels Plastic box Main Power Supply...230VAC ± 10% Back-up Power Supply...1 battery, 12V/ 7Ah Main power supply consumption ma Auxiliary output...24vdc/ 0.3A fuse Internal resistance of the battery...<0.45 Ohm Operating temperature...-5 C to +40 C Weight (without battery)...2.4kg Dimensions of the plastic box...340x290x100mm MAG 8 Plus EN54-2/4 Conventional fire alarm control panel 8 to 16 zones, expandable Supports up to 32 detectors and call points per zone 4 monitored siren outputs - 0,3 A each Double knock mode Siren delay Supports relay expander MR 8 and LOG module ML Active EOL allowing continuous monitoring of inputs Levels of access protected by means of key Simple programming by means of jumpers Multi language front panels Plastic box Main Power Supply...230VAC ± 10% Back-up Power Supply...1 battery, 12V/18Ah Main power supply consumption...50ma Auxiliary output...24vdc/ 0.3A fuse Operating temperature...-5 C to +40 C Weight (without battery)...4kg Dimensions of metal bottom...441x331x80mm Dimensions of plastic cover...461x344x45mm ML LOG module for recording and viewing of events Compatible with MAG8 and MAG8Plus Memory for 510 events Operation keypad with 4 buttons LCD display with backlight Multilingual menus MR 8 8 relay expander module Compatible with MAG8 and MAG8Plus 1A/12 V or 0.5A/24V MS 4 4 siren outputs expander module Compatible with MAG8Plus ME 4 4 zone expander module Compatible with MAG8Plus 17
18 SensoMAG Conventional detectors SensoMAG F10 Fixed heat detector Detects temperatures over 60 C, class A2S (SensoMAG F10A) Detects temperatures over 75 C, class BS (SensoMAG F10B) Digital processing algorithm Protected area - up to 35 sq. m. Low profile design LED indication with 360 visibility Sensor status indication on every 8 seconds EN54-5 SensoMAG R20 Rate-of-rise heat detector Detects temperatures above 58 C or rapid change in temperature for a period of time, class A1R Digital processing algorithm Protected area - up to 35 sq. m. Low profile design LED indication with 360 visibility Sensor status indication on every 8 seconds EN54-5 SensoMAG S30 Optical-smoke detector Auto compensation Digital processing algorithm Protected area - up to 120 sq. m. Low profile design LED indication with 360 visibility Sensor status indication on every 8 seconds Rubber gasket ring EN54-7 SensoMAG M40 Multi criteria (Optical-smoke and Heat) detector Auto compensation Digital processing algorithm Protected area - up to 120 sq. m. LED indication with 360 visibility Sensor status indication on every 8 seconds Rubber gasket ring EN54-5/7 18
19 SensoMAG Conventional detectors SensoMAG MCP 50 Manual call point Surface mounting Resettable flexible element LED indication Special test tool for resetting after alarm event Optional protective plastic cover IP40 EN54-11 SensoMAG B24 Standard 24V base for SensoMAG detectors Compatible with fire panels alarm state current up to 15 ma SensoMAG B24D Standard 24V base with Schottky diode for SensoMAG detectors Detects removal of detector from base Compatible with fire panels with alarm state current up to 15 ma SensoMAG B24RD Standard 24V base with Schottky diode and increased alarm state current for SensoMAG detectors Detects removal of detector from base Compatible with fire panels with alarm state current up to 45 ma SensoMAG B12L/U Relay 12V base For application in intruder alarm system Latched/Unlatched mode 19
20 Sirens Conventional SF 100 Indoor fire alarm siren and strobe Piezo sounder LED strobe Sound output: High level db; Low level - 92 db Low profile design Max. consumption 20mA@27VDC 32 Sound types 2 Outputs for evacuation and fire alarm Two wire connection SF 105 Indoor fire alarm siren Piezo sounder Sound output db LED strobe Plastic case Power supply - 24 V Two wire connection Current - 80 ma EN54-3 EN54-3 SF 110 Indoor fire alarm siren Piezo sounder Sound output db Power supply - 24 V Plastic case Current ma EN54-3 SF 200 Outdoor fire alarm siren LED strobe 1 status indicator Sound output - 96 db Plastic case IP54 protection for electronics Current - 90 ma EN54-3 SF 300 Outdoor fire alarm siren LED strobe Sound output - 95 db Plastic case IP54 protection for electronics Current - 90 ma EN
21 Accessories Fire alarm systems EN54-23 FRL - 1 Remote 24V fire indicator Repeats the status of 1 or several fire detectors (up to 3 SensoMAG or SensoIRIS detectors) 1 input Deep Base Deep base accessory Application for mounting on rough surfaces, pipelines, floating ceilings, etc Compatible with SensoMAG and SensoIRIS Call-point plastic cover set Set of 5 pcs. protective plastic cover for manual call-points Compatible with SensoMAG MCP 50 and SensoIRIS MCP 150 FLM Kit Kit for flush mounting For use on 25 mm thick dry wall Includes: 2 hangers, mounting screws Compatible with IRIS and MAG8plus Battery Box Metal box Place for 2 accumulator batteries12v/ 18Ah (max. size of a battery 167x181x76mm) Colour - white Dimensions - 310x411x82mm PS2410 Power supply unit 24 V DC/1A Metal box Transformer EN54-4 Fire Ray 50R/ 100R Reflective infrared beam detector VDC Low current consumption Model 50R (5-50m) Model 100R (50-100m) EN
22 Programming Software is a software package for programming of Teletek Electronics intruder and fire alarm panels. The software allows fast and user-friendly programming to the benefit of installers. Supported products Eclipse 8 Eclipse 16 Eclipse 32 Eclipse 99 BRAVO VEGA6 IRIS SIMPO ARGUS AJAX LAN AJAX GPRS/GSM AJAX GPRS/GSM Simple TP2000 (ver. 8.xx) ProsTE Advantages Intuitive and user friendly graphic interface Easy programming of all system parameters Saves time and effort Allows creation of default configurations in tdf (teletek data files) ready for use on site Decreases possibility for mistakes during programming need to remember addresses or use programming manuals Completely free download and update available at Multi language support Help wizard OBSERVER Monitoring Software Observer is a software application for monitoring of sites equipped with Teletek Electronics addressable fire alarm systems. Functional Specifications In accordance with the technical and functional specifications of Teletek Electronics addressable fire alarm panels Supports up to 32 panels with 1000 devices per panel Monitors the condition and state of detectors - Alarm, rmal, Fault Shows full information about the detector in alarm state - zone, name, etc Monitors faults in the panel - Low Batt, AC Loss, etc Allows control over the panel - silence buzzer, silence sirens, evacuation, reset Allows import of architectural plans and pictures on which the detectors are placed (JPG, BMP, PNG, TIF, GIF) Keeps printable event log Signals visually and audibly in case of alarm or fault ModBus protocol included 22 Observer Advantages Direct ProsTE files import (Device name, zone name, panel name and panel IP address) Devices Drag and drop placement Panels control Minimum programming Simple and User Friendly Interface Windows XP and Windows 7 support Multi language support Protection by means of password and hardware key (Dongle) Event audio signalization
23
24 www. teletek-electronics.com a: Srebarna 14А Str, Sofia , BULGARIA t: (+359 2) f: (+359 2) e: [email protected] 03/2015
25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008
Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)
Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
2015 Intruder Alarm Systems Product Catalogue
2015 Intruder Alarm Systems Product Catalogue Table of contents 2015 Intruder Alarm System 4 6 7 8 9 10 11 12 14 16 17 18 19 20 21 22 23 25 27 28 29 30 32 33 34 35 36 37 Company Profile Eclipse series
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
Always on the Lookout Perfect Protection against Burglary
Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on
FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system
FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description
INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's
ACTIVE 5 ENGINEERING MANUAL
ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
GST301. (Single Protection Zone) Operation Manual
GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...
SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description
SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped
Premier M Plus & Infinity 8
25 Years of Manufacturing Excellence Premier M Plus & Infinity 8 Conventional Fire Alarm Systems 007 Assessed to ISO 9001: 2008 Certificate number 330 Premier M Plus 8-24 Zone Conventional Fire Alarm Panel
Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems
Alarm Systems Agri-Alert alarms have been protecting swine operations across the world since 1997. Peace of Mind The Agri-Alert alarm system constantly monitors your operation and quickly notifies you
CB200W Water Leak Detection Panel Application Guide
Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
VEGA Analogue Addressable Control Panels
Analogue Addressable Control Panels Representing the future of fire alarm control technology, Vega's modular concept enables the tailoring of system design for the smallest to the largest system. Designed
Fire Alarm Control Panel. Family. Operating Manual
Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...
25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals
INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce
9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19
TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as
Fire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Fire & Security DETECTORS
Fire & Security DETECTORS Smoke Sensitivity 0.98 ~.0%/ft Obscuration Ceiling Spacing 50 foot rating for heat sensor Temperature Range 10ºC to 50ºC Humidity 0 to 95% RH, no condensation or icing Dimensions
Product Information Fire alarm panel 8000 C
Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000
Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX
Global System Technology(UK) PLC The Intelligent Solution
Global System Technology(UK) PLC The Intelligent Solution MANUFACTURED IN ACCORDANCE WITH Intelligent Photoelectric Smoke Detector Aesthetically pleasing Low profile design 8 Bit intelligent processor
conventional system operation
conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than
HyperAccess Access Control System
Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000
Analogue addressable devices
Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet
C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems
P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier
DC-8706K Auto Dial Alarm System
DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power
HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS
ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION 2014 Ferport/Armas has over 30 years been synonymous with technology, reliability and experience in
Six-defense zone Display Alarm System. User Manual
Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode
Fire detection equipment
PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
AlarmSense 2-wire detection and alarm system. Product Guide
AlarmSense 2-wire detection and alarm system Product Guide Contents What is AlarmSense? 2 The purpose of AlarmSense 4 How AlarmSense works 4 Alarmsense Features 5 Detector removal monitoring 5 Priority/non-priority
DTW Works Master Specification Version 2006
Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual
EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: [email protected]
INTELLIGENT MONITORING FOR SAFER BUSINESS
INTELLIGENT MONITORING FOR SAFER BUSINESS PANASONIC FIRE ALARM SOLUTIONS TECHNOLOGY FOR A BETTER WORKING WORLD CHOOSE PANASONIC FIRE SOLUTIONS AND YOU RE CHOOSING WORLD-CLASS PROTECTION With more than
Microprocessor Home Security System
numbers of sensor s activations in the zone and after which activations the zone will be discarded (ignored). On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a
UniOP epad33 and epad33t
UniOP epad33 and epad33t The epad33 and epad33t are state-of-the-art HMI devices with a 10.4 graphic display and a complete keypad. The aluminum bezel offers an appealing look in a rugged and convenient
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
Home Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15
HomeSafe-Basic VT-PS99E User s Manual PSTN Home Alarm System Page: 1 / 15 Table of Contents 1. Product Overview:... 3 2. Main Functions & Features... 3 3. For Your Safety... 4 4. VT-PS99E Characteristics...
Wireless Alarm system s manual
MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most
AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS
AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT ALARM SYSTEMS Peace of Mind Agri-Alert is a complete alarm system for monitoring temperature, power, feed and watering systems, burglary,
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
Expansion Modules & Accessories
HONEYWELL SECURITY & CUSTOM ELECTRONICS Expansion Modules & Accessories Honeywell s wide range of expansion modules and accessories enable you to configure a system to meet any installation challenge and
INSTALLATION MANUAL PC2525. Version 1.1
INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...
TS510 & TS500. Installation & User Guide. Compatible Equipment
Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction
Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications
Gen4 Intruder Alarm Panels SIMPLY SECURE For Residential & Small Commercial Applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection
Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide
Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware Specifications 7 4.0 Software
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Control/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as
WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
Software Release For DF6000/CF3000/FX6000. Site Installer Network Card
Software Release For DF6000/CF3000/FX6000 Site Installer Network Card DF6000/CF3000/FX6000 Software Updates Latest Version: Display 3.03.50 Loop: 3.2.4 (14) Engineering Change Note : 1163 Site Installer
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
TAC I/NETTM. Intrusion Alarm System
TAC I/NETTM Intrusion Alarm System The TAC I/NET intrusion alarm system (IAS) consists of a mix of security control products that can be combined and configured to provide intruder detection and alarm
Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.
Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology,
PRODUCT CATALOGUE. www.detectomat.com
PRODUCT CATALOGUE 20 06 The Group contents 1. fire control panels 1.1 detect 3004 fire control panel and accessories...4-11 1.2 detect 3016 fire control panel and accessories...12-17 1.3 detect 3004/3016
PCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Alliance System Ordering Guide
Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers
Wireless Auto-dial Intruder Alarm System
Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
ACCESS CONTROL SYSTEM
ACCESS CONTROL SYSTEM Flexible, Expandable, Economical. The i-pass system comprises of the i-pass controller built with state of the art technology to provide reader access for up to 16 doors and 32 elevator
Class 2 transformer (TBT) Low Tension Conform to EN 60742. A LED turns ON when the current exceeds 1 A at the 14V output connector
Technical notice TECHNICAL CHARACTERISTICS Power Class 2 transformer (TBT) Low Tension Conform to EN 60742 Rechargeable battery 16 Vac, 50-60Hz 50 Va min. 250 Va max 12 V, 7AH Protection A LED turns ON
Controller board and power supply for vivimat III systems
Controller board and power supply for vivimat III systems Ref: VIVIMAT-3.0 The controller board and power supply vivimat 3.0, is the central core of the vivimat III home automation system. The vivimat
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
FX 3NET + SLC FIRE ALARM SYSTEM Part 1: General Rules
Planning Instruction 66571758GB0 49/2011 Fire Detection FX 3NET + SLC FIRE ALARM SYSTEM Part 1: General Rules These are the planning instructions for an FX 3NET fire detection and alarm system consisting
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
Iphone & Android App Smart GSM Home Alarm System
Iphone & Android App Smart GSM Home Alarm System PST-GA242Q User Guide Version V14.3 Dear User, Thanks for selecting the intelligent alarm system. Please read through this guide before installation so