RAPPORTO DI PROVA TEST REPORT
|
|
- Estella Parks
- 8 years ago
- Views:
Transcription
1 RAPPORTO DI PROVA TEST REPORT Titolo (Title): DEGREES OF PROTECTION PROVIDED BY EMPTY ENCLOSURES (IP55 CODE) on UNIVERSAL RACK UR Richiedente (Customer): - Ente/Società (Dept./Firm): C.E.P.I RACK S.r.l - Sig.(Mr. ): Gianfranco Cavallini - Indirizzo (Address): Via A. Volta DRUENTO ( TO ) - Modulo Richiesta Prova n.: Rapporto inviato a: Test Requesting Form no.: Report sent to: 060_11_STAMB Sig. Gianfranco Cavallini Nome e Firma esecutore prova: Name and Signature of the test engineer: Nome e Firma Responsabile settore:d.mazzei Name and Signature of the Sector Manager Data ricevimento campioni: 2011/03/30 Data esecuzione prove: from 2011/03/30 Date of test samples receipt: Date of test execution: to 2011/05/24 Località esecuzione prove (se diversa dal pié di pagina): Site of test execution (if different from the address in the footer): Presenti alle prove IPX5: Witness to the test: Sig. Gianfranco Cavallini I risultati del presente rapporto di prova si riferiscono esclusivamente al campione sottoposto a prova. The test results contained in this Test report relate to the tested samples only. E' ammessa la riproduzione integrale del presente Rapporto di prova da parte del Richiedente; la riproduzione parziale dev'essere autorizzata per iscritto dal Laboratorio. The integral reproduction of the present Test report is allowed; the partial reproduction must be authorized in writing by the Lab. Page 1 of 14
2 1. SETUP DI PROVA TEST SETUP 1.1. IDENTIFICAZIONE CAMPIONE SAMPLE IDENTIFICATION - Prodotto/materiale sottoposto a prova: Rack Product/material subjected to test: - Descrizione: Universal Rack UR Description: - Livello (Prodotto di serie, prototipo, ecc.): Prototype. Level (Series product, prototype, etc.): - N Matricola: / Part number: - Codice di identificazione: C Identification code: 1.2. DISPOSITIVI AUSILIARI / AUXILIARY DEVICES 1.3. CONFIGURAZIONE DI PROVA The E.U.T. was not operating. See tecnical drawings TEST CONFIGURATION at SISTEMA DIAGNOSTICO Verify that the water and powder are not entered DIAGNOSTIC SYSTEM into the protected space of the cabinet. See technical drawings at ELENCO DELLE PROVE TEST LIST - VERIFICATION OF DEGREE OF PROTECTION AGAINST THE INGRESS OF SOLID FOREIGN OBJECTS FOR IP 5X ENCLOSURES 13.4 category 2 ( without vacuum pump ) of IEC apply - TEST FOR SECOND CHARACTERISTIC NUMERAL 5 3. METODO DI PROVA TEST METHOD X Normalizzato - Norma di riferimento: IEC 62208:2002 Standardized - Reference Standard: Interno - Descrizione: Internal - Description: Eventuali scostamenti, aggiunte o limitazioni: Possible differences, additions or limitations: Page 2 of 14
3 4. APPARECCHIATURE UTILIZZATE TEST EQUIPMENT USED - DUST CHAMBER EUROTEST CODE IPPCHR01 - STANDARD TEST NOZZLE AND TOOLS FOR SECOND CHARACTERISTIC NUMERAL 5 5. CONDIZIONI AMBIENTALI ENVIRONMENTAL CONDITIONS Temperature = 23 C Relative Humidity = 49% Atmospheric pressure = 1009 mbar 6. INCERTEZZA DI MISURA MEASUREMENT UNCERTAINTY Expanded uncertainty ±5% l/min Corresponding to a confidence level of about 95% 7. PIANO DI CAMPIONAMENTO SAMPLING PLAN Samples selected by the customer 8. RISULTATI DELLE PROVE E/O MISURE TEST AND / OR MEASUREMENT RESULTS 1. VERIFICATION OF DEGREE OF PROTECTION AGAINST THE INGRESS OF SOLID FOREIGN OBJECTS FOR IP 5X ENCLOSURES 13.4 category 2 ( without vacuum pump ) of IEC apply. The device under test, was inserted in the dust chamber without vacuum pump. Ingress of talcum powder into protected space is verified as a follows: ingress of talcum powder is verified by using a watch glass installed at the centre of the base of the protected space of the enclosure in order to pick up the talcum powder entering the protected space during the test. After the test, talcum powder shall not form deposits of more than 1 g/m2. in practice the weight of the watch glass is measured before and at the end of the test and the difference between both measures is representative of the amount of the talcum powder which has entered the protected space. Test duration: 8 hour. RESULTS: At the end of test a visual internal inspection was made and no powder was found on the watch glass according to IEC 62208:2002. The enclosure can be classified IP5X degree in according to IEC 62208:2002. Page 3 of 14
4 2. TEST FOR SECOND CHARACTERISTIC NUMERAL 5 The device under test was spray from all practicable direction with a stream of water from a standard nozzle of CEI EN 60529: standard. The observed conditions were as follows: - Internal diameter of nozzle: 6,3 mm - Delivery rate: 12,5 l/min ± 5% - Water pressure: adjusted to achieve the specific delivery rate - Core of the substantial stream: circle of approximately 40 mm diameter at 2,5 m distance from nozzle - Distance from nozzle to enclosure surface: between 2,5 and 3 m. - Test duration: 3 min. RESULTS: At the end of test, a visual inspection was made: WATER WAS FOUND but not in the protected space ( see photos at 10 ). The enclosure can be classified IPX5 degree in according to IEC 62208: NOTE REMARKS The IP5X test was performer by an external laboratory Il tets IP5X è stato eseguito da un laboratorio esterno. The configuration has been supplied by the customer. La configurazione e stata fornita dal cliente The customer is responsible for the paragraph 1.1 reported data and for the configuration of the tested EUT. Il cliente e responsabile per i dati riportati al paragrafo 1.1 ( Identificazione campione ) e per la configurazione dell EUT testato The sample under test was returned to the customer. Il campione testato è stato restituito al cliente The names of files and drawings were sent by the customer I nomi dei file e dei disegni sono stati inviati dal cliente. Page 4 of 14
5 10. APPENDICE (documentazione fotografica del setup di prova / allegati) APPENDIX (photographic report test setup / attachments) IPX5. Universal Rack UR under test Page 5 of 14
6 IPX5. Universal Rack UR under test Page 6 of 14
7 Visual internal inspection Page 7 of 14
8 Visual internal inspection Page 8 of 14
9 Gasket Lock Page 9 of 14
10 Technical drawings.gaskets Page 10 of 14
11 Technical drawings Page 11 of 14
12 Technical drawings Page 12 of 14
13 Technical drawings Page 13 of 14
14 Technical drawings Page 14 of 14
TEST REPORT RAPPORTO DI PROVA TEST ON TYRES ACCORDING TO CLIENT PROCEDURE
TEST REPORT RAPPORTO DI PROVA TEST ON TYRES ACCORDING TO PROVE SU GOMME IN ACCORDO A PROCEDURA CLIENTE Customer (Richiedente): - Dept./Firm (Ente/Società): A.S.A. AZIENDA SERVIZI A.N.I.M.A. S.r.l. - Mr./Mrs
More informationRAPPORTO DI PROVA TEST REPORT. Titolo (Title): EMC Immunity test and measure of the harmonic components and Flicker on. SP40 plus
RAPPORTO DI PROVA TEST REPORT Titolo (Title): EMC Immunity test and measure of the harmonic components and Flicker on SP40 plus Richiedente (Customer): - Ente/Società (Dept./Firm): Compuprint S.p.A. -
More informationTEST REPORT RAPPORTO DI PROVA EMC tests on
TEST REPORT RAPPORTO DI PROVA EMC tests on BIG POWER Test di compatibilità elettromagnetica BIG POWER Customer (Richiedente): - Dept./Firm (Ente/Società): T.P.A. IMPEX S.p.A. - Mr./Mrs. (Sig./Sig.ra.):
More informationSAFETY DOESN T HAPPEN BY ACCIDENT. PV MOUNTING SYSTEM TOGETHER WITH ANTI-FALL SYSTEM A PERFECT TEAMWORK
SAFETY DOESN T HAPPEN BY ACCIDENT. PV MOUNTING SYSTEM TOGETHER WITH ANTI-FALL SYSTEM A PERFECT TEAMWORK FOR PV power PLANTs. The history of Lizard 1965 1958 Production of boilers and burners Foundation
More informationTEST REPORT RAPPORTO DI PROVA CONFORMITY TEST ACCORDING TO EN 1176:2008 ON PLAYGROUND EQUIPMENT
TEST REORT RAORTO DI ROVA CONFORMITY TEST ACCORDING TO EN 1176:2008 ON LAYGROUND EQUIMENT ROVE DI CONFORMITA IN ACCORDO ALLA EN 1176:2008 SU ATTREZZATURE ARCHI GIOCO Customer (Richiedente): - Dept./Firm
More information: ARLIN - TEXTILE WALLCOVERING
COSTRUZIONI CONSTRUCTION REAZIONE REACTION 1 Nome commerciale Product Name : ARLIN - TEXTILE WALLCOVERING Descrizione : Vedi pagina 2 Description : See page 2 Nome / Name : ARLIN ITALIA S.r.l. Indirizzo
More informationRAPPORTO DI PROVA / TEST REPORT
RAPPORTO DI PROVA / TEST REPORT Rif./Ref.No. FCCTR_130738-0 Data / Date: 17/09/2013 Pagine / Pages : 15 Scopo delle prove /Test object : Richiedente / Applicant : Persona di riferimento / Applicant s referee
More informationGIBITRE INSTRUMENTS S.R.L. VIA MEUCCI 1 24035 CURNO BG ITALY INTERNAL TENSOR CHECK. GIBITRE Instruments TENSOR CHECK COMPACT-PC
RAPPORTO DI TARATURA N. PROVA123456 Report of Calibration No. Pagina 1 di 6 Page 1 of 6. - Data di emissione date of issue - destinatario addresse - richiesta application - in data date Si riferisce a
More informationDegrees of protection. IP codes. W.M.M. Menheere Holec Holland N.V. The Netherlands
Degrees of protection IP codes W.M.M. Menheere Holec Holland N.V. The Netherlands 1 INDEX Introduction...3 1. The IEC protection code (International Protection IP)...3 2. Interpreting the IP code...3 3.
More informationTEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio
TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),
More informationELENCO PROVE ACCREDITATE - CATEGORIA: 0
Scheda 1 di 8 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Concentrator photovoltaic (CPV) modules and assemblies 10.1 Ispezione visiva / Visual inspection IEC62108:2007 10.1 + CEI IEC 61215:2005 10.1 10.10
More informationDICHIARAZIONE DI PRESTAZIONE DECLARATION OF PERFORMANCE Ai sensi del REGOLAMENTO (UE) N. 305/2011
DICHIARAZIONE DI PRESTAZIONE DECLARATION OF PERFORMANCE Ai sensi del REGOLAMENTO (UE) N. 305/2011 n. 16-1154-2013 1. Codice di identificazione unico del prodotto-tipo: Unique identification code of the
More informationDry Corp, LLC July 14, 2011 349 Military Cutoff Road Wilmington, NC 28405
MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE! BALTIMORE, MARYLAND 21230-3432! PHONE (410) 354-3300! FAX (410) 354-3313 Dry Corp, LLC July
More information28924 Verbania Fondotoce (VB) Italia 29/04/2008 Page 1 of 5 CLIENTE Customer SHIELD s.r.l. Strada Provinciale, 21/A 28010 Cavaglietto (NO) COMMESSA Contract CO006908-23/04/2008 RAPPORTO DI PROVA Test Report
More informationHow To Become A Payment Agent In Italy
How to submit your application to sign up the Register of Credit Intermediaries Special Section: Payment Service Agents Guidance to Natural Persons 1) Following successful attendance of the Training Course
More informationPAESE/COUNTRY: Certificato veterinario per l'ue/veterinary certificate to EU
PAESE/COUNTRY: Certificato veterinario per l'ue/veterinary certificate to EU Parte I: relative alla partita/part I: Details of dispatched consignment I.1. I.5. Speditore/Consigner Nome/Name Indirizzo/Address
More informationWhite Paper IK code: Impact protection in line with the IEC 62 262 standard. By Sven Schnautz
White Paper IK code: Impact protection in line with the IEC 62 262 standard By Sven Schnautz Contents List of images... 3 List of tables... 3 List of figures... 3 Introduction... 4 Basic principles...
More informationMaster of Advanced Studies in Music Performance and Interpretation
Master of Advanced Studies in Music Performance and Interpretation The MAS in Music Performance and Interpretation is designed for students who already have a degree in musical studies and are interested
More informationMetal Working S.r.l. is an innovative company with a clear view. From design to products manufacturing, Metal Working takes care of every aspect of
COMPANY PROFILE Metal Working S.r.l. is an innovative company with a clear view. From design to products manufacturing, Metal Working takes care of every aspect of production in its headquarter in Trentino,
More informationCUSCINETTI E SUPPORTI
CUSCIETTI E SUORTI _00_00 CUSCIETTI SU SUORTI A FAGIA QUARA BEARIGS O SQUARE FAGE SUORTS IAMETRO ABERO - SHAFT IAMETER 40 mm 50 mm 60 mm 70 mm 80 mm 90 mm 100 mm IMESIOI IGOMBRO - OVERA IMESIOS iametro
More informationEN20 EN50. Double-stage modular decompression unit for oenological application. FEATURES Dual inlet and single outlet decompression unit.
Strada dei Boschi, 40 20852 Villasanta (MB) Italia tel. +39 039 302035 info@idinsertdeal.com www.idinsertdeal.com EN20 EN50 Double-stage modular decompression unit for oenological application FEATURES
More informationGOLD EFFECT series MRK-010-0131
MRK-010-0131 GOLD EFFECT series TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco mediante
More informationELENCO PROVE ACCREDITATE - CATEGORIA: 0
Scheda 1 di 9 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Concentrator photovoltaic (CPV) modules and assemblies 10.1 Ispezione visiva / Visual inspection IEC 62108:2007 10.1 +IEC 61215:2005 10.1 10.10 Water
More informationROSA ANTICO series MRK-010-0174
MRK-010-0174 ROSA ANTICO series TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco mediante
More informationLeannovazione R&D project management: processes
Technology Centre-ABB- ITALY P. Bertolotto - December 14st 2015 Leannovazione R&D project management: processes Copyright 2014 ABB. All rights reserved. Agenda - Reasons of structured approach - R&D processes,
More informationCorso: Administering Microsoft SQL Server 2012 Databases Codice PCSNET: MSQ2-1 Cod. Vendor: 10775 Durata: 5
Corso: Administering Microsoft SQL Server 2012 Databases Codice PCSNET: MSQ2-1 Cod. Vendor: 10775 Durata: 5 Obiettivi Pianificare e installare SQL Server. Descrive i database di sistema, la struttura fisica
More informationINFORMAZIONI GENERALI / GENERAL INFORMATION
INFORMAZIONI GENERALI / GENERAL INFORMATION LE FLANGE DELLA SOCIETà INTERTUBI SONO FORNITE IN ACCORDO ALLE SEGUENTI NORME: INTERTUBI S FLANGES ARE PROVIDED IN ACCORDING WITH THE FOLLOWINGS STANDARDS Norma
More informationELENCO PROVE ACCREDITATE - CATEGORIA: 0
Scheda 1 di 7 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Crystalline silicon terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva/visual inspection IEC 61215:2005 10.1 10.10 Prova di precondizionamento
More informationRPS. Sanitary sampling valves SAMPLING
Sanitary sampling valves SAMPLING CHARACTERISTICS The fully autoclavable sampling valves are designed for aseptic sampling of liquids and pharmaceutical products. Made entirely in AISI 316L, the standard
More informationPage 2 of 59. Copy of marking plate: Copia della piastra della marcatura:
Specification of the Test Object (Oggetto Del Test) CEI 11-20 (2004-08) e alla norma ENEL DK 5940 Ed. 2.2 (Aprile 2007) Automatic disconnecting facility for photovoltaic installations Rapporto prove numero...:
More informationPRESSACAVI CABLE GLANDS
CTLOGO GENERLE / GENERL CTLOGUE PRESSCVI CLE GLNDS SERIE SERIES PGIN PGE 8.1 PRESSCVI STGNI PER CVO RMTO P-PE-PS 8-2 SEMPLICE TENUT WTER-DUSTPROO CLE GLND OR RMOURED CLE 8.2 PRESSCVI STGNI PER CVO RMTO
More informationéq studio srl Technical product specification for the certification and communication of vegan products aimed at informed consumers.
éq studio srl Technical product specification for the certification and communication of vegan products aimed at informed consumers. Specifica Tecnica di prodotto STP QV Qualità Vegana Edizione 01 Revisione
More informationANSI/IEC 60529-2004. Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption)
ANSI Approval Date November 3, 2004 ANSI/IEC 60529-2004 Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption) Published by: National Electrical Manufacturers Association
More informationipratico POS Quick Start Guide v. 1.0
ipratico POS Quick Start Guide v. 1.0 Version History Version Pages Comment Date Author 1.0 First Release 5/Marzo/2012 Luigi Riva 2 SUMMARY 1 GETTING STARTED 4 1.1 What do you need? 4 1.2 ipad 5 1.3 Antenna
More informationParticolari unici e profumi esclusivi svelano l essenza di una realtà in continuo divenire.
Particolari unici e profumi esclusivi svelano l essenza di una realtà in continuo divenire. Unique details and exclusive scents reveal the essence of a continuously developing reality. brunito kevlar
More informationVersione: 2.1. Interoperabilità del Sistema di Accettazione di SPT
Versione: 2.1 Interoperabilità del Sistema di Accettazione di SPT INDICE 1 Definizione del tracciato di scambio... 2 1.1.1 XML SCHEMA...... 3 1 Definizione del tracciato di scambio Il documento riporta
More informationDal nostro Partner di Enterprise Europe Network, CATT Innovation Management GmbH (Austria), arriva la seguente richiesta di cooperazione:
Enterprise Europe Network Richiesta Cooperazione 2 Dal nostro Partner di Enterprise Europe Network, CATT Innovation Management GmbH (Austria), arriva la seguente richiesta di cooperazione: Titolo: martello
More informationBureau Veritas Consumer Product Services GmbH
Specification of the Test Object (Oggetto Del Test) CEI 11-20 (2004-08) e alla norma ENEL DK 5940 Ed. 2.2 (Aprile 2007) Automatic disconnecting facility for photovoltaic installations Rapporto prove numero...:
More informationContenitori Enclosures
- 19 - Contenitori Enclosures Contenitori in materiale termoplastico per ausiliari di comando Ø 22 Thermoplastic enclosures suitable for control units Ø 22 Dati tecnici generali / General Technical Data
More informationTO THE MEDIA REPRESENTATIVE The accreditation procedure to the 2015 WSK Series has started.
TO THE MEDIA REPRESENTATIVE The accreditation procedure to the 2015 WSK Series has started. The accreditation request must arrive by January 15 th 2015. To request the accreditation to the single event,
More informationMarine after-treatment from STT Emtec AB
Marine after-treatment from STT Emtec AB For Your Vessel and the Environment Recommended by Volvo Penta 16 15 5 6 10 8 13 2 14 12 3 4 7 9 11 1 1. SCR Catalyst 2. Injection nozzle 3. Mixer unit 4. Diagnostic
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationDECLARATION DE CONFORMITE Declaration of Conformity
DECLARATION DE CONFORMITE Declaration of Conformity Nous, We, ABB Control (nom du Fournisseur / Supplier's name) 10 rue ampère, ZI 69685 CHASSIEU (France) (adresse / address) déclarons sous notre seule
More informationENVIRONMENTAL TEST REPORT
INFN - Roma doc: UG crate FM - ESS date: 9/12/08 pag: 1 /12 ENVRPT33_S3019R-UG crate FM_ESS- date: December 09, 2008 Prot: 001-09/SERMS signature test report prepared by: test report controlled by: 09/12/08
More informationTest report. The above described product sample is tested to measure his power performance
Sede legale: Via Bussoli, 9 Sede operativa: Via Mantegna, 3 5 35020 TRIBANO (PD) ITALY P.IVA e C.F. (VAT): 04682560281 Cap. Soc. 10.000 i.v. Tel. [+39] 049 5342234 Mobile [+39] 340 3570822 e-mail: info@wtlab.org
More informationref. 5 Giada G+F in linea/in line Porta doccia a 1 anta battente e 1 pannello fi sso in linea in nicchia / In line hinged door + panel for recess
ref. 5 Giada G+F in linea/in line Porta doccia a 1 anta battente e 1 pannello fi sso in linea in nicchia / In line hinged door + panel for recess 184 GIADA ref. 3 Giada 2B Porta doccia a 2 battenti + fi
More information10156 TORINO (ITALY) 21, Via Cuorgnè - Tel. +39.011.22.22.225 Fax +39.011.22.22.226 e-mail: info@modulouno.it web: www.eurofins.com TECHNICAL REPORT
10156 TORINO (ITALY) 21, Via Cuorgnè - Tel. +39.011.22.22.225 Fax +39.011.22.22.226 e-mail: info@modulouno.it web: www.eurofins.com TECHNICAL REPORT SKN_N0106.R19 Specific CEN Keymark Scheme Rules for
More informationSAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND
SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING May 2014 BACKGROUND There has been a recent serious incident involving a large arc event caused by material falling through an opening in a switchboard
More informationPDP and SD Series Pump Station
PDP and SD Series Pump Station 1 THE COMPANY SEIM, after 35 years of production, have achieved a leading position in the screw pump market world wide. Our high volume production of market leading products(more
More informationPlease take note that only the document on paper support shall be considered as the authentic ACAE Certificate of conformity.
Subject: Compact Disk (CD) of Certificate of conformity Please take note that only the document on paper support shall be considered as the authentic Certificate of conformity. General Secretary Virginio
More informationCopy of marking plate: Copia della piastra della marcatura: Display front:
Page 1 of 32 Specification of the Test Object (Oggetto Del Test) CEI 11-20 (2004-08) e alla norma ENEL DK 5940 Ed. 2.2 (Aprile 2007) Automatic disconnecting facility for photovoltaic installations Rapporto
More informationEdiz.: Issue: Firma Signature. Data Date. Sardo G. (DT/MT/) ASI 1 x
Tipo Doc.: Doc.Type: N Doc.: Doc. N : PROCEDURE N DRD: DRD N : NA Di Of Titolo : Title : Preparato da: Prepared by: Nome & Funzione Name & Function Zambra R (DT/MT/) Firma Signature Data Date LISTA DI
More informationCorso: Supporting and Troubleshooting Windows 10 Codice PCSNET: MW10-3 Cod. Vendor: 10982 Durata: 5
Corso: Supporting and Troubleshooting Windows 10 Codice PCSNET: MW10-3 Cod. Vendor: 10982 Durata: 5 Obiettivi Al termine del corso i partecipanti saranno in grado di: Descrivere i processi coinvolti nella
More informationNB-CE Instruction Manual
Receiver NB-CE Digital RF Receiver with high sensitivity, selectivity and immunity to electromagnetic fields interferences, obtained by means of SAW filter at input and metallic shield. Pin-out Code Lot
More informationQSLM 2000. Dual inlet decompression unit with automatic change-over system FEATURES
Strada dei Boschi, 40 20852 Villasanta (MB) Italia tel. +39 039 302035 info@idinsertdeal.com www.idinsertdeal.com QSLM 2000 Dual inlet decompression unit with automatic change-over system FEATURES It allows
More informationMotori elettrici corrente continua. DC motors MCC
03 G 20 -IN ITA Motori elettrici corrente continua DC motors MCC MOTORI IN C.C. S INDICE - INDEX Riferimento Reference Motore tipo Motor type Pagina Page Riferimento Reference Motore tipo Motor type Pagina
More informationITALIAN LANDSCAPE ARCHITECTURE HISTORY AND SEMIOLOGY OF LANDSCAPE AND GARDENS IN UMBRIA UNIVERSITY FOR FOREIGNERS OF PERUGIA 3-13 SEPTEMBER 2012
ITALIAN LANDSCAPE ARCHITECTURE HISTORY AND SEMIOLOGY OF LANDSCAPE AND GARDENS IN UMBRIA UNIVERSITY FOR FOREIGNERS OF PERUGIA 3-13 SEPTEMBER 2012 The universe as we know it today is in constant flux in
More informationFascicolo prove. / Tests report file. Inverter eolico
CEI 0-21 Fascicolo prove / Tests report file Rapporto di prova n CEI0-21 01 25304-130115 /Test report No. Prodotto in prova /Product under test Costruttore /Manufacturer Tipo - Modello /Type - Model Inverter
More informationExplosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
More information22/11/2015-08:08:30 Pag. 1/10
22/11/2015-08:08:30 Pag. 1/10 CODICE: TITOLO: MOC20462 Administering Microsoft SQL Server Databases DURATA: 5 PREZZO: LINGUA: MODALITA': 1.600,00 iva esclusa Italiano Classroom CERTIFICAZIONI ASSOCIATE:
More informationSFxxx-S PID Test Report (Potential Induced Degradation) TUV Rheinland Japan. ARC Product Management 2015.07 Ver. 1
SFxxx-S PID Test Report (Potential Induced Degradation) TUV Rheinland Japan ARC Product Management 2015.07 Ver. 1 Outline SLIDE 1 2 Outline What is PID? TOPICS 3 4 5 6 7 8 Principle of PID & resistance
More informationHorizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2
0932 Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46 1 Index 1 Index... 2 2 Description of the Inputs / Outputs... 4 2.1 Inputs / Module OMRON ID201 / ID211...4 2.2 Outputs / Module OMRON OC211...5
More informationexpanded metal on stock lamiera stirata in stock
expanded metal on stock lamiera stirata in stock Fratelli Mariani S.p.A. da 80 anni produce lamiera stirata e tela metallica. L azienda, di 0 dipendenti, ha la sua sede operativa a Cormano, alle porte
More informationStreet lighting luminaire BABEL. Registered model - Design Massimo Sacconi. NERO e GRIGIO per marchi piccoli. (ha il filo ingrossato)
BABEL Street lighting luminaire Registered model - Design Massimo Sacconi BABEL is the LED technology high power light tower for the illumination of roundabouts, car parks, and large areas. With high performance
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationMedical Devices Data Bank. User Manual DM Manufacturer Profile
Medical Devices Data Bank User Manual Version 1.1 February 2008 SISG_SSW.MSW_DISPO_RDM_MTR_Manufacturer_v1.1.doc February 2008 1/166 SUMMARY 1. INTRODUCTION..4 1.1 DEFINITIONS AND GLOSSARY...5 1.1.1 Glossary
More informationFAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
More informationTEST REPORT EN 55014-2 (1997) +A1 (2001)
Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....
More informationNon solo un gruppo digitale: UNA VERA STAZIONE DI LAVORO! Not only a digital manifold: A TRUE WORK-STATION! NEW FOX EVO. Torr mtorr micron inhg
FOX EVO 62 Gruppo manometrico digitale a vie VANTAGGI EVO VACUOMETRO ELETTRONICO DI ALTA PRESSIONE INTEGRATO (0 900 Pa) BILANCIA, CAPACITÀ 0 100 KG, RISOLUZIONE 2G DATA LOGGER INTEGRATO MICRO SD CARD INCLUSA
More informationwww.evocorse.com evo@evocorse.com tel 049 936 5050 fax 049 936 8896
Following up the great success of the Sanremo 15 line, the best and the most popular wheel on the market, the Evo Corse team, thanks to the experience acquired during these years with the competitions
More informationVdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationPASSASPINA E VASCHETTE CANCELLERIA CABLE HOLDERS AND STATIONERY TRAYS
S E Z I O N E 0-2 0 1 4 COLORI/FINITURE STANDARD STANDARD COLOURS/FINISHINGS COLORE NERO cod. 09004 BLACK Colour 09004 COLORE ANTRACITE cod. 07016 ANTHRACYTE Colour 07016 art./09004 (34/09004) COLORE GRIGIO
More informationMADE IN ITALY. Sistemi di connessione per fotovoltaico Connection systems for photovoltaic. TÜV certification EN 50521:2008 SC3
Sistemi di connessione per fotovoltaico Connection systems for photovoltaic TÜV certification EN 505:008 SC Tipologia di prodotto Definizione modelli Informazioni Valori nominali Indice Index Datasheet
More informationConverting the Stay Permit
Converting the Stay Permit From study to work Content 2 1. Before or after graduation? 2. Filling in the online forms 3. From student permit to employee permit. 4. From student permit to independent worker
More informationRefurbishment Rifacimenti Porte
2XX ENG-ITA Refurbishment Rifacimenti Porte Sales Brochure Brochure Commerciale 281-011-000 E 2 May 2006 The best solution for modernising any type of old lift doors to the latest Sematic 2000 series design
More informationVia Montello 10 - Borgo Montello 04100 (Latina) Italy 19 Fern Street - Surfers Paradise 4217 QLD Australia
RESUME Personal information First name, Surname Address Telephone Skype e-mail Nationality Date of birth Occupational field Davide Costa Via Montello 10 - Borgo Montello 04100 (Latina) Italy 19 Fern Street
More informationAMDx4 INTERFACE CONTROL PANEL FOR AUTOMATIC SOFTENERS AM/D METER
AMDx4 INTERFACE CONTROL PANEL FOR AUTOMATIC SOFTENERS AM/D METER INSTRUCTIONS MANUAL INSTRUCTIONS FOR INSTALLATION OPERATION & MAINTENANCE WARNING! The equipment must be used only for the utilization for
More informationCable glands and accessories Pressacavi ed accessori
Cable glands and accessories Pressacavi ed accessori IP66 metal cable glands Pressacavi IP66 metallici Metal type Tipo metallico No. of gaskets No.guarnizioni Internal dia of gasket Dia. interno guarnizione
More informationTRI CLAMP PRESSURE REGULATORS
Strada dei Boschi, 40 20852 Villasanta (MB) Italia tel. +39 039 302035 info@idinsertdeal.com www.idinsertdeal.com TRI CLAMP PRESSURE REGULATORS Stainless steel AISI 316L pressure regulators with clamp
More informationBasic requirements 999GG01834
Basic requirements / DIVISIONE INGEGNERIA E INNOVAZIONE AREA DI BUSINESS SVILUPPO E REALIZZAZIONE IMPIANTI 1 Ince Sicurezza Security Index TITOLO Title Basic requirements for the Suppliers qualification
More informationSolving the Problem of Motor Protection from Moisture, Water and Dust in Commercial Refrigerators.
WHITE PAPER Solving the Problem of Motor Protection from Moisture, Water and Dust in Commercial Refrigerators. Saving Generation for the Next Generation Overview Moisture, and dust are common causes of
More informationDew-Point Measurement Solutions
Dew-Point Measurement Solutions www.michell.com Dew-Point Measurement Solutions Special Features No downtime Michell Instruments offers a unique sensor exchange programme, which means that you will never
More informationMeasurement of RF Emissions from a Final Coat Electronics Corrosion Module
Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA
More informationMODULO D'ISCRIZIONE/ APPLICATION FORM. c/o C. T. A. di Vietri sul Mare Piazza Matteotti I- 84019 Vietri sul Mare (SA) ITALIA
MODULO D'ISCRIZIONE/ APPLICATION FORM Completare scrivendo in stampatello/please use BLOCK LETTERS da spedire a/ send by mail to: Segreteria del Concorso e del Premio di esecuzione pianistica Internazionale
More informationUSERS MANUAL IN.TRA.NET PROJECT
This project has been funded with support from the European Commission. This publication (communication) reflects the views only of the author, and the Commission cannot be held responsible for any use
More informationAPPLICATION PROCEDURES STEP BY STEP
APPLICATION PROCEDURES STEP BY STEP STEP ONE: a) APPLICATION ONLINE Once we receive your names and dates of birth you will receive an e-mail with the Access Code to proceed with the Application Online.
More informationDESCRIZIONE DEI MATERIALI MATERIAL INFORMATION
DESCRIZIONE DEI MATERIALI MATERIAL INFORMATION Ottima resa elastica, resistenza all usura, al taglio e alla lacerazione, buon allungamento alla rottura. Temperatura di impiego: -40 C +100 C. Durezza 45
More informationIR WINDOW CERTIFICATION GUIDEBOOK. Copyright CorDEX Instruments Ltd. www.irwindows.com training@cord ex.com. ID 4016 Rev A
IR WINDOW CERTIFICATION GUIDEBOOK Copyright CorDEX Instruments Ltd. www.irwindows.com training@cord ex.com ID 4016 Rev A Content 1. General... Page 3 2. Introduction... Page 4 3. UL Underwriters Laboratories...
More informationTRENTINO - The research, training and mobility programme in Trentino - PCOFUND-GA-2008-226070
Ricercatore: Ilya Afanasyev Soggetto ospitante: UNIVERSITA' DEGLI STUDI DI TRENTO Bando: Incoming post doc 2009 Soggetto partner (solo per outgoing): e-mail: ilya.afanasyev@unitn.it, ilya.afanasyev@gmail.com
More informationTesting laboratory HVAC. Test report No.: HP-06525-e
Testing laboratory HVAC Test report No.: HP-62-e Objective: Sound measurements on an air distribution box and an air inlet Client: RoomAir AG Thurstrasse 14 Postfach 81 Frauenfeld Date: 26-6-2 This report
More informationTechnical application guide IP codes in accordance with IEC 60529
www.osram.com Technical application guide IP codes in accordance with IEC 60529 What are IP codes? Depending on their potential exposure to foreign objects, electrical devices (e.g. luminaires, LED modules
More informationPower meter. Caratterizzazione di amplificatori a RF. Amplificatori a RF. Incertezza 8-03-2012. Corso di Laboratorio di misure ad alta frequenza
Corso di Laboratorio di misure ad alta frequenza Caratterizzazione di amplificatori a RF Docenti: Andrea Mostacci; Alessandra Paffi andrea.mostacci@uniroma1.it; paffi@die.uniroma1.it A.A. 2011-2012 Sensori:
More informationDUAL FUEL BURNERS GAS/HEAVY OIL
M A D E I N I TA LY SERIE KN 750/M_1000/M EL DUAL FUEL BURNERS GAS/HEAVY OIL BRUCIATORI MISTI GAS/OLIO COMBUSTIBILE All purpose heating solutions Soluzioni integrate per il riscaldamento All purpose heating
More informationUser Manual ZMONITOR. Tool for managing parametric controllers
User Manual ZMONITOR Tool for managing parametric controllers INDICE 1. PRESENTATION... 4 MINIMUM SYSTEM REQUIREMENTS... 4 DEVICES TO BE MANAGED ZMONITOR... 5 2. INSTALLATION... 6 3. LANGUAGE... 8 4. MAIN
More informationScrewless terminal blocks Morsettiere a molla
SECTION 2 / SEZIONE 2 CONNECTION SYSTEM: SCREWLESS CONNESSIONE SENZA VITE w ww.euro cl amp.it (. eu ) PRODUCT PRODOTTO PITCH () PASSO () DESCRIPTION DESCRIZIONE PAGE PAGINA SPRING / MOLLA MVEM50V 5 Vertical
More informationDott Bruno Fornengo Laurea in Medicina e chirurgia 1980 Specialista in ORTOGNATODONZIA 1984 Insegnante a contratto Università di Torino dipartimento
Y O U C A N Dott Bruno Fornengo Laurea in Medicina e chirurgia 1980 Specialista in ORTOGNATODONZIA 1984 Insegnante a contratto Università di Torino dipartimento di chirurgia Maxillo Facciale Master il
More informationQuestionario Medico Medical Questionnaire
Nome e Cognome Name and lastname Sesso Sex Data di nascita Date of birth Altezza Height Peso attuale Current weight Avete mai avuto una diminuzione o aumento di peso (più di 5 kg.) Have you ever had shrinkage
More informationConverting the stay permit. from study to work
Converting the stay permit from study to work Contents: 1. Before or after graduation? 2. Filling in the online forms 3. From student permit to employee permit 4. From student permit to independent worker
More informationKIT MODULO LED E DRIVER PER ILLUMINAZIONE ESTERNA E INDUSTRIALE KIT LED MODULE AND DRIVER FOR OUTDOOR AND INDUSTRIAL LIGHTING
12 IT MODULO LED E DRIVER PER ILLUMINAZIONE ESTERNA E INDUSTRIALE POER 30 700 ma TESTO HL 30 equivalente: 30-50-70 HID Consumo: 35 Lumens reali: 2.400 Lumen per att : 80 Equivalent : 30-50-70 HID Consumption:
More informationHow To Manage A Network On A Pnet 2.5 (Net 2) (Net2) (Procedure) (Network) (Wireless) (Powerline) (Wired) (Lan 2) And (Net1) (
Il presente documento HLD definisce l architettura e le configurazioni necessarie per separare la rete di management dai servizi dati dedicati al traffico cliente, con l obiettivo di poter accedere agli
More information