TMP6100EAS/470 Marking System
|
|
|
- Ralph Shaw
- 10 years ago
- Views:
Transcription
1 TMP6100EAS/470 Marking System General Arrangement Drawing SYSTEM OVERVIEW The Telesis TMP6100EAS/470 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic. An electric solenoid accelerates a hardened pin to indent dot matrix characters into the item being marked. Character shape, size, density, and location are determined by the user through the marking system software. The system is compliant with UL, CSA, CE, and RoHS specifications. The TMP6100E Marking Head is an electromechanical marker. The internal, mechanical components position the pin cartridge and an electric solenoid fires the marking pin. A spring returns the pin to its idle position within the cartridge. The system software automatically controls pin extension to mark the message. The TMP6100E marking head is a polar-coordinate, robotic mechanism which uses stepper motors to independently drive its A- and B-arms. This design provides a generous 12 x 6 in. (304 x 152 mm) marking window. The marking head moves the pin cartridge through the required polar rotation motions to reach the correct position for each dot. It accurately and rapidly positions the pin cartridge at coordinate-defined locations within.002 in. (0.05 mm) of any point in the window. The pin design permits high quality, consistent marks on irregular, slightly curved surfaces. It also accommodates applications where marking surfaces cannot be positioned at a consistent distance from the marker. The Marker Cable connects the marker to the controller. The highly flexible cable is 4m (13 ft.) long. Optional extension cables are available for greater distances. The Pin Cartridge, machined from engineered plastic materials, offers long life with little maintenance. Screws attach the pin cartridge to the marking head for easy removal, cleaning, and pin replacement. The 25XLE-series Marking Pins are made of tungsten carbide and are available in 30 and 45 cone angles. TMC470 Controller contains an integrated keyboard with an LCD display. It provides a text-only operator interface to fully operate the TMP6100E marking head. The back panel provides the electrical interface for connecting to optional, remote I/O sources. Refer to TMC470 Controller Specifications for details. Z-axis Toolpost. The Z-axis toolpost allows the software to position the marker up and down the toolpost. The toolpost is provided with systems configured for Electric-pin Auto Sense (EAS). Auto Sense uses the Z-axis software to automatically position the pin at a programmable distance above the marking surface. The Z-axis features require an additional Aux Axis board. Systems configured for EAS already have the required board installed in the controller. For systems not configured for EAS, the toolpost and board may be purchased separately. Optional System Computer. The TMC470 Controller may be connected to a PC that runs the Merlin III Visual Design Software. The PC may be supplied by Telesis or by the customer. Refer to PC-based Merlin III Software and TCP/IP Interface for details D Telesis Technologies, Inc. All Rights Reserved 1 of 8
2 TMP6100E Marking Head Dimensions SYSTEM SETUP EAS systems will require the TMP6100E to be mounted on a Z-axis toolpost. Non-EAS systems should be mounted to a fixture with the pin pointing downward. Please consult with a Telesis representative for other mounting orientations. If you design a mounting fixture, allow for 3-axis adjustment to aid in horizontal, vertical, and lateral alignment of the marking head. 1. Place tool post (or other suitable mounting fixture) on a sturdy, level surface. 2. Mount marking head using two ½-13 bolts. CAUTION The TMC470 is not a sealed unit. Protect it from potentially damaging conditions and contaminants. Do not block vents in bottom of case. Ensure the marking system is electrically isolated from any devices that may generate extreme electromagnetic interference (EMI). 3. Locate controller as close as practical to marking head. Standard marker cable length is 4 m (13 ft.). 4. Install the controller as a table-top, wall-mounted, panelmounted, or enclosure-mounted unit, as applicable. 5. Ensure controller power switch is OFF. 6. Connect marker cable to marking head and to controller. 7. For EAS systems, connect Auxiliary Axis cable to the controller and to toolpost. 8. If your system uses the optional Merlin software, connect system computer to controller. Unless the system computer was supplied by Telesis, you must install the Merlin software. 9. Connect power cable to controller and to power outlet. 10. Position controller power switch to ON. 11. Start marking system software and Merlin (if applicable). 12. If your system uses the optional Merlin software, configure the Ethernet/Merlin communication parameters. 13. For EAS systems, configure the Z-axis Zero Offset and Auto Sense parameters. 14. Adjust pin stroke for desired impact depth. 2 of D
3 SYSTEM OPTIONS Auxiliary Axis Driver Board Kit Motorized, Programmable Z-axis Toolpost Motorized, Programmable Theta-axis Rotary Drive Unit Manually Adjustable Toolpost Marking Head Extension Cables TMC470 Controller Wall-mounting Bracket Kit TMC470 Controller Panel-mounting Bezel/Bracket Kit TMC470N NEMA Enclosure Bar Code Scanner or Bar Code Wand with Cable Foot Switch (Start Print) Pushbutton Station (Start/Abort) Backup Utility Software Upgrade Utility Software Logo/Font Generator Software Merlin III Visual Design Software System Computer (to run the Merlin III software) These items are required to use the programmable Z-axis and Auto Sense features. These items are automatically provided when the marking system is purchased from Telesis as a pre-configured Electric-pin Auto Sense (EAS) system. For all other systems, the toolpost and auxiliary axis board are optional and may be purchased separately. Not available for EAS systems. TMP6100E MARKING HEAD Specifications The TMP6100E marking head specifications are subject to change without prior notice. Dimensions... see TMP6100E Marking Head Dimensions drawing for details Weight lb. (7.6 kg) without support tooling Operating Temp to 122 F (0 to 50 C), non-condensing Marking Area x 6.0" (304 x 152 mm)) Pin Types... 25XLE-series (30 or 45 tip) Pin Material... Tungsten Carbide Pin Life Pin life depends largely on the type of material being marked, how hard or abrasive it is, and the required marking depth. On typical metals with a hardness of Rockwell Rb47, marking at a depth of.127 mm (.005"), carbide pins average approximately 9 million impressions before needing sharpened. Marking Characteristics The TMP6100E can produce characters as small as.06 in. (1.5 mm), printed at any angle within the 12 x 6 in. (304 x 152mm) marking window. Printing resolutions range from 4 to 79 dots per cm (10 to 200 dots per inch) for an engraved look. Marking Speeds Generally, the system will mark two characters per second (using 5x7 font,.125" [3 mm] high characters). The marking speed can be adjusted to allow more precisely formed characters. Doing so, under these same conditions, will result in reduced marking speeds. Specific times can be verified by a Telesis representative. Marking Noise Although every attempt is made to reduce noise, the material being marked significantly influences the noise level. For example, marking a solid lead block produces less noise than marking a thin-walled steel pipe. Marking Depth The TMP6100E can obtain a marking depth of.127 mm (.005") in mild steel (Rb53) using a 25XLE carbide pin with a 45 cone angle. The depth of mark can be adjusted over a significant range by changing the impact distance (pin stroke) or the impact force (software parameter). Specific depths can be verified by a Telesis representative D 3 of 8
4 TMC470 Controller Dimensions Table-top and Wall-mounted Configurations TMC470 CONTROLLER The TMC470 controller may be installed as a table-top unit, a wall-mounted unit, a panel-mounted unit, or an enclosuremounted unit. All configurations provide features and connectivity for external communications. Differences occur only in the mounting configuration. TMC470 Specifications The TMC470 Controller specifications are subject to change without prior notice. Compliance... CE, RoHS Configurations... Table-top, Wall-mounted, Panel-mounted, or Enclosure-mounted Rating... NEMA 1 (I.P. 30) table-top or wall-mounted NEMA 12 (I.P. 65) panel-mounted using appropriate customer-supplied panel NEMA 12 (I.P. 65) enclosure-mounted using Telesis-supplied TMC470N enclosure Dimensions... refer to the appropriate TMC470 Controller Dimensions drawings Weight lb. (1.68 kg) controller only 3.90 lb. (1.77 kg) with wall-mount kit 5.52 lb. (2.51 kg) with panel-mount kit 28.1 lb. (12.77 kg) with TMC470N enclosure TMC470 Specifications (continued) Operating Temp to 122 F (0 to 50 C) Operating Humidity. 10% to 80% non-condensing Cooling... Internal, thermostat-controlled fan Power Requirements. 95 to 250 VAC, 2 amps, Hz, single phase Communications... TTL, Discrete I/O, RS232, RS485, TCP/IP, and USB (for data backup and transfer) Input Signals... Twelve (12) total, optically isolated: 8 dedicated, 1 programmable, 3 available 10 VDC (minimum voltage) 30 VDC (maximum voltage) 12 to 24 VDC (nominal voltage) VDC; VDC (nominal current) Output Signals... Six (6) total, optically isolated: 4 dedicated, 2 available 0.25 amps (maximum current) 0.50 ohms (maximum On resistance) 40 VDC (maximum line voltage) 12 to 24 VDC (nominal line voltage) 4 of D
5 TMC470 Controller Dimensions Panel-mounted Configuration Environmental Considerations The following environmental considerations must be taken into account when installing the TMC470 Controller. Contaminants. The vented TMC470 is rated NEMA 1 (IP30) and contains a thermostatically-controlled, variable speed fan. Accordingly, in environments where solid and/or liquid contaminants are present, the possibility exists that these contaminants can be drawn into the TMC470 controller and possibly result in failure. For that reason, in these types of environments, the controller must be located in a sealed industrial enclosure. To facilitate such installations, Telesis offers on optional panel mounting kit for use with an appropriate customer-supplied panel or enclosure. Telesis also offers an optional TMC470N NEMA 12 (I.P. 65) enclosure in which the controller can be mounted. EMI Susceptibility. Although the system has been found to be in compliance with pertinent susceptibility standards, care should be taken when installing near welders and other extreme generators of electromagnetic interference (EMI). Particular care should be taken to ensure welder currents are not injected through the marking head chassis. The marking head chassis is connected to the electrical service earth ground through the marking head cable. The marking head should be electrically isolated from all surfaces which could become part of a welder current path. TMC470-based System Software The system software is permanently installed in the controller. It provides the user interface for the operator to control the marker. The software also provides a library for storing, loading, and editing user-defined patterns. Patterns are files stored in the controller s memory. Depending on the size of the pattern files, the controller can store up to 200 patterns. Each pattern contains one or more fields; each field defines a single object. Printable objects may be created to define text strings, arc-text strings, geometric shapes, graphics, and machine-readable data matrix symbols. Non-printable objects may be defined to specific commands to the marker (e.g., Pause, Go to, Input, or Output). Printable text fields may include alphanumeric characters, symbols, and special message flags. Message flags automatically insert data into the text string, such as serial numbers, times, dates and user-defined codes. PC-based Merlin III Visual Design Software Optionally, the TMC470 Controller may be connected to a PC that runs the Telesis Merlin III Visual Design Software. The software is a 32-bit Windows based WYSIWYG application that provides a graphical user interface to make pattern design quick and easy. Just click and drag for immediate adjustment to field size, location, or orientation. The Merlin III software includes tools to create and edit text, arc text, rectangles, circles, ellipses, and lines. Existing DXF files can also be imported for marking. After downloading patterns to the controller, the PC can be disconnected from the controller to allow the TMC470 to control marking operations. Optionally, the PC may remain connected to the controller and allow the Merlin III software to fully control the marking system D 5 of 8
6 TMC470 Controller Dimensions Enclosure-mounted Configuration Interface Panel The back panel of the controller provides various ports for connecting the marker, host computers, logic controllers, optional accessories, and remote I/O devices. See below. Serial Interface. The Comm 1 and Comm 2 Ports allow connection to remote serial devices such as a host computer or a bar code scanner. See Host Communications for details. Discrete I/O Interface. The optically-isolated I/O Port allows you to connect a Programmable Logic Controller (PLC) or other DC I/O source for remotely controlling marker operations. See Discrete I/O Controls for details. TTL Interface. The TTL Port allows the system to connect with a simple contact closure circuit such as a remote push button station or foot pedal switch. These types of devices can remotely control Start Print and Stop Print operations. TCP/IP Interface. The Ethernet Port typically connects to a PC over a local area network (LAN). It allows you to define the controller as a client or a server socket using Telesis Extended Protocol. See Host Communications for details. USB Interface. The USB Port allows you to connect a memory stick/flash drive for pattern storage/retrieval and for software upgrades. Auxiliary Axis Interface. The Auxiliary Axis Port allows the system to connect with up to four optional motion devices such as motorized toolposts, rotational drive units, and linear slides or actuators. For pre-configured EAS systems, this Aux Axis board is already provided. For non-eas systems, this board is optional. Discrete I/O Controls The TMC470 is configured for 12 VDC to 24 VDC I/O only and is provided to connect a PLC or other DC I/O source. The optically-isolated I/O Port allows you to remotely select and load patterns, start printing, stop printing, place the marker online, and monitor the system output signals. Cable connectors and connector pins are supplied with the controller for constructing appropriate interface cables. Input Signals. These input signals provide the following controls: INPUT COMM... For all inputs (+ or supply) START PRINT... Begins print cycle STOP... Stops the print cycle SEL_0 thru _6 *... Remotely selects & loads up to 127* pattern files SPARE_1, 2, 3... Three (3) spares for custom applications * System software allows SEL_6 signal to be configured for remotely selecting patterns or for remotely placing the marker online. If used for marker online, pattern selection is reduced to 63 patterns (max). Output Signals. These output signals indicate the following states: OUTPUT COMM... For all outputs (+ or supply) DONE... Print cycle is complete READY... System ready for message or for start print command PAUSED... System paused (waiting timeout or command) NO FAULT... System status (normal or fault detected) SPARE_1, 2... Two (2) spares for custom applications 6 of D
7 Host Communications The marking system software allows you to configure communication parameters to transmit and receive data to and from a host computer. To provide maximum integration flexibility, the system software supports RS-232 and RS-485 serial interfaces and Ethernet TCP/IP interfaces. The system software also provides two protocol choices: Programmable Protocol and Extended Protocol. RS-232 Interface. The serial (RS-232) communications interface is most often used with remote devices such as host computers, terminals, or bar code scanners. The Comm 1 RS-232 interface supports both Telesis Extended Protocol and Telesis Programmable Protocol. The Comm 2 RS-232 interface supports only Telesis Programmable Protocol. RS-485 Interface. The RS-485 interface is normally used for long transmission distances or multi-drop networks of up to 31 TMC470 controllers. You must use Telesis Extended Protocol with the RS-485 interface. The following describes the serial data character format on all transmissions to and from the TMC470 Controller. Asynchronous 1200, 2400, 4800, 9600, 19200, 38400, or Baud 1 or 2 Stop Bits 7 or 8 Data Bits None, Even or Odd Parity TCP/IP Interface. The Ethernet (TCP/IP) interface is most often used with host computers communicating over a local area network (LAN). You must use Telesis Extended Protocol with the TCP/IP interface. The Port parameter identifies the host computer socket that is assigned to the marking system. If more than one marking system is installed in a network configuration, each system must use a separate and unique port number. The Address parameter identifies the IP address of the host computer. The marking system software supports both fixed addressing and dynamic addressing. Optionally, the Ethernet Port may be connected to a PC running the Merlin III Visual Design Software. Any computer that runs the Merlin III software must satisfy the following requirements: Windows 2000, Windows XP, Windows Vista (Business Edition), or Windows 7 (Professional Edition) Operating System Pentium 4 Processor Sufficient RAM as per Operating System Requirements Video Board Multi-Gigabyte Hard Drive CD-ROM Disk Drive One Available Ethernet Port (minimum) SVGA Color Monitor, Mouse, and Keyboard Programmable Protocol. Use this protocol where very simple one-way communications are required (such as with bar code scanners). Programmable Protocol provides no error checking or acknowledgment of the transmitted data. Note that XON/XOFF Protocol applies even when Programmable Protocol is selected. Starting Character specifies where the software begins to count character positions. This number must be entered in decimal format (e.g., "2" for ASCII Start of Text "STX"). Terminating Character identifies the end of transmitted string (usually "13" for ASCII carriage return character). Character Position counted from the starting character ignoring all characters preceding it. Character Length accepts variable length messages (if set to 0) or messages of a pre-specified, fixed number of characters. Ignore Character identifies the character to ignore when sent from the host (usually "10" for ASCII line feed character)). Message Type allows message-type recognition which defines how the marking system will use data it receives from the host. 1 Message type 1 overwrites the first line of the first text field with data extracted from the host P Message type P loads a specific pattern identified by data extracted from host Q Message type Q updates the text in the first query buffer with data extracted from the host V Message type V updates the first variable text flag found in the pattern with data extracted from the host 0 Message type 0 (zero) indicates that host will provide message type, field number (if applicable), line number (if applicable), and data; delegates message type selection to the host on message-bymessage basis. The host message must use the format: Tnn<string> where: T nn = 1, P, Q, or V to indicate message type = two-digit field number or query text buffer where data will be placed. Note: Not used with Message Type P. <string> = For Message Type P, indicates the pattern name to be loaded. For Message Types 1, Q, or V, indicates the data to be inserted into the field or the query text buffer, as applicable D 7 of 8
8 Host Communications (continued) Extended Protocol. This protocol selection includes error checking and transmission acknowledgment. It should be used in applications where serial communication is a vital part of the marking operation. All communications are carried out in a parent/child relationship with the host being the parent. Only the host has the ability to initiate communications. If the host does not receive a response within three seconds, it should re-transmit its original message. If no response is received after three tries, it should declare the link to be down. The following describes the Extended Protocol message format as sent from the host to the TMC470 controller SOH TYPE [##] STX [DATA] ETX BCC CR where: SOH ASCII Start of Header character (001H). The controller ignores all characters received prior to the SOH. TYPE A single, printable ASCII character that defines the meaning (type) and content of the message downloaded from the host, where: 1 Message Type 1 overwrites a specific field in currently loaded pattern with data supplied in the host message. See [DATA] for details. P Message Type P specifies the pattern name to be loaded for printing. See [DATA] for details. Q Message Type Q updates a specific query buffer with data supplied in the host message. See [DATA] for details. V Message Type V updates the variable text in a specific text field of the currently loaded pattern with data supplied in the host message. See [DATA] for details. O Message Type O resets marker and places it online G Message Type G initiates a print cycle to mark the currently loaded pattern I Message Type I requests the marker return the status of standard output and input signals. The system will return a hexadecimal code for the 6 output signals and 12 input signals in the following format: OO;III where: bit 1 READY 0x01 bit 2 DONE 0x02 bit 3 PAUSED 0x04 bit 4 NO_FAULT 0x08 bit 5 SPARE_1 0x10 bit 6 SPARE_2 0x20 bit 1 START 0x001 bit 2 STOP 0x002 bit 3 SEL_0 0x004 bit 4 SEL_1 0x008 bit 5 SEL_2 0x010 bit 6 SEL_3 0x020 bit 7 SEL_6 * 0x040 bit 8 SEL_4 0x080 bit 9 SEL_5 0x100 bit 10 SPARE_1 0x200 bit 11 SPARE_2 0x400 bit 12 SPARE_3 0x800 Note: Input SEL_6 may be configured to place machine online (default) or for Remote Pattern Selection. [##] Optional two-digit ASCII number that specifies the Station ID of the controller when used in multi-drop network applications. The Station ID may range from Note that 00 is reserved for applications where only one controller is used. In such applications, this field may be eliminated and 00 will be assumed. STX ASCII Start of Text Character (002H). [DATA] Optional character string that may be required for certain message types (e.g., Type 1, P, Q, and V). Typically, data is sent in the format: nn<string>. where: ETX BCC CR nn = two-digit field number or query text buffer where data will be placed. Note: Not used with Message Type P. <string> = For Message Type P, indicates the pattern name to be loaded. For Message Types 1, Q, or V, indicates the data to be inserted into the field or the query text buffer, as applicable. ASCII end of text character (003H). Optional Block Check Code that is generated and sent to improve link reliability by providing fault detection. The BCC is calculated by taking an eight bit addition of the TYPE and DATA TEXT characters and transmitting them as a three digit ASCII decimal number in the range from 000 to 255. If the sum is greater than 255, the most significant bit overflows and is discarded. ASCII Carriage Return Character (00DH). TRADEMARKS Telesis and PINSTAMP are registered trademarks of Telesis Technologies, Inc. in the United States. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. Pentium is a registered trademark of Intel Corporation in the United States and other countries. Windows and Vista are registered trademark of Microsoft Corporation in the United States and other countries. 8 of D
BenchMark 460 Marking System
BenchMark460 Marking System General Arrangement Drawing SYSTEM OVERVIEW The Telesis BenchMark 460 marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic.
TMP3200/470 Marking System
TMP3200/470 Marking System General Arrangement Drawing System Overview The Telesis TMP3200/470 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and
TMP1700/420 DATASHEET
System Overview The Telesis TMP1700/420 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic. A hardened pin is pneumatically accelerated
Custom FQ30 Laser Marking System
FQ30 Laser Marking System General Arrangement SYSTEM OVERVIEW The Telesis FQ30 is one laser in a family of maintenance-free, Q-switched, Ytterbium fiber lasers designed for marking applications. These
CO30A Laser Marking System
CO30A Laser Marking System General Arrangements SYSTEM OVERVIEW The Telesis CO30A is a 30-watt, RF-excited, continuous wave, sealed-tube, CO 2 laser marking system that provides a galvosteered beam designed
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program
CNC File Transfer Box The CNC File Transfer connects a serial CNC device to the network so files can be easily transferred from a computer to the CNC equipment. Any computer on the network can transfer
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION
MACHINEMATE CNC SYSTEM Hardware SPECIFICATION Feb 2005 CONTENTS 1 Introduction / General... 3 1.1 Superior Capability in Technology and Productivity... 3 1.2 General hardware components... 4 1.3 Static
dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October 2002 Information
Senses SV series industrial monitor user manual
Industrial Monitors Senses SV series Senses SV19 / SV17 User manual (Issue A) Part No: 85090084 Page 1 of 25 Copyright Copyright 2008 Amplicon Liveline Ltd. All rights reserved. This publication, including
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.
Motorized Actuators Motor Cables EZS /EZS for Clean Room Use This cable is a dedicated cable for connecting the linear slide of the EZS Series and EZS Series for Clean Room Use with the controller. Use
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual
LaserProbe4500 CNC-STEP "LaserProbe4500" 3D laser scanning system Instruction manual 2 Hylewicz CNC-Technik Siemensstrasse 13-15 D-47608 Geldern Fon.: +49 (0) 2831 133236 E-Mail: [email protected] Website:
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
PPM Users Manual Signature Software 01-12-00
PPM Users Manual Signature Software 0-2-00 PPM User Manual /8/02 Software Versions: 0.0.27 Contents. Introduction 2 2. Parameters 3 2. Overload Limit...4 2.2 Relative Upper Limit...4 2.3 Relative Lower
Vision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems
Vision Engravers and Routers PRE-Installation Guide Revised: 8/19/2015 Vision Engravers and Routers PRE-Installation Guide All rights reserved. No parts of this work may be reproduced in any form or by
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
WinPFT File Transfer Utility (Catalog No. 2711-ND7)
Technical Data WinPFT File Transfer Utility (Catalog No. 2711-ND7) Overview WINPFT is a stand-alone Windows utility which lets you transfer applications developed for standard PanelView terminals or Dataliner
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
PU-USBX. USB over Ethernet Extender OPERATION MANUAL
PU-USBX USB over Ethernet Extender OPERATION MANUAL Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply.
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
DCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
Industrial Bar Code Scanners
DS6400 Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack APPLICATIONS Automated warehousing Medium conveyor sorting Reading on forklift trucks Picking systems Automated shop
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
Tracer Summit Web Server
Tracer Summit Web Server Web-based access for the Tracer Summit building automation system March 2003 BAS-PRC014-EN Introduction The Tracer Summit Web Server provides the ability to operate a Tracer Summit
ANA: ARCNET Network Analyzer
ANA: ARCNET Network Analyzer Accurately monitors real-time data traffic Displays all low-level ARCNET frame types including ITT, FBE, ACK, NAK, and Packet data Intelligent acquisition unit that does not
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
Ultra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
Model 5511 Filler Controller User s Manual Version 1.1 October 2011
Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
NG360 Inclinometer with digital RS485 communications port and 360 degree measuring range
Inclinometer with digital RS485 communications port and 360 degree measuring range Features integrated 16bit microprocessor RS485 bus output signal no measuring range limitation 0.01 degree resolution
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
Product Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
Dell Latitude E6320. Setup and Features Information. About Warnings. Front and Back View
Dell Latitude E6320 Setup and Features Information About Warnings WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Front and Back View Figure 1. Front view 1. microphone
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
PM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12
6AV3017-1NE30-0AX0 Page 1 Product data sheet 6AV3017-1NE30-0AX0 TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12 Supply voltage
USB Plus+ RFID Reader Setup Guide
875-0042-03 RevA USB Plus+ RFID Reader Setup Guide 1 Government Limited Rights Notice: All documentation and manuals were developed at private expense and no part of it was developed using Government funds.
Korosi Monitoring System (KMS) Software Manual
PT. KOROSI SPECINDO Corrosion Monitoring System Eng. Doc. No.: KS-MNL-KMS Korosi Monitoring System (KMS) Software Manual Revision Date Prepared Approved Description 0 23/05/2008 ES JH Issued for approval
6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.
6AV3617-1JC30-0AX1 Page 1 Product data sheet 6AV3617-1JC30-0AX1 OPERATOR PANEL OP17/DP12 LC DISPLAY, BACKLIT LED 4X20/8X40 LINESXCHARACTERS SIMATIC S5, 505, S7, M7, NATIVE DRIVERS, PROFIBUS-DP 12 MBAUD,
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
MI4 - Operator Panel : Engineering
MI4 - Operator Panel : Engineering MI4 - Operator Panel : Engineering Overview MI4 Text Operator Panel MI4 Graphic Operator Panel MI4 Touch Operator Panel Communication modules Accessories MI4-CFG-1 Engineering
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
EPSON Scan Server & EPSON TWAIN Pro Network
EPSON Scan Server & EPSON TWAIN Pro Network EPSON Scan Server & EPSON TWAIN Pro Network SCANNER UTILITY PROGRAMS All rights reserved. No part of this publication may be reproduced, stored in a retrieval
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS stam-irs_en 01/11 STAM-IRS is a dedicated server to be used with the STAM-2 monitoring station which enables receiving transmissions sent via telephone
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
Intelligent RS-485 I/O expansion unit: RU-87Pn Series
INTRODUCTION RU-87Pn series is a remote intelligent I/O expansion unit that used to expand i-87k series I/O modules over the RS-485 for industrial monitoring and controlling applications. There are more
ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.
ISO-9001:2000 certified EE300 Series Electromechanical Inventory Level Measuring System Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION OPERATING PRINCIPLE The EE300 series level measuring system is a
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
Bluetooth HC-06 with serial port module Easy guide
1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as
Application & Quick-Start Guide
Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface
DSA-1000 / PRT-1000 Device Server / Thermal Printer
LevelOne DSA-1000 / PRT-1000 Device Server / Thermal Printer User Manual V2.0 TABLE OF CONTENTS 1. INTRODUCTION...- 3-2. DEVICE OVERVIEW...- 7-3. HARDWARE SETUP...- 10-4. SYSTEM CONFIGURATION...- 12 -,
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
SiloPatrol. SiloTrack Inventory Management Software Version 3.5 BULLETIN 343B. Interface With Multiple Sensor Technologies
Setting The Standard For Supplier Excellence SiloPatrol SiloTrack Inventory Management Software Version 3.5 Interface With Multiple Sensor Technologies Simple Local And Remote User Access Vendor/Remote
Industrial Bar Code Scanners
DX8200A Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack ASTRA technology APPLICATIONS Postal/Courier parcel sorting and tracking Automated warehousing identification systems
Sierra S-Series Smart Interface Software User Manual
Sierra S-Series Smart Interface Software User Manual Part Number IM-SIP 08/99 Revision B 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 http://www.sierrainstruments.com
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware
A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components
TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
Job Aid Pre-Installation Information S8500 Media Server
Required information Job Aid Pre-Installation Information S8500 Media Server This job aid provides the information, hardware requirements, and computer hardware and software specifications necessary for
Dell Vostro 3350/3450/3550/3750
Dell Vostro 3350/3450/3550/3750 Setup And Features Information About Warnings WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Front and Back View Vostro 3350 Figure
Control Technology Corporation CTC Monitor User Guide Doc. No. MAN-1030A Copyright 2001 Control Technology Corporation All Rights Reserved Printed in USA The information in this document is subject to
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
UniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation
Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
DRO Function guide: Zero setting 1/2 calculation mm/inch conversion INC/ABS conversion
Digital Readout Standard Type Machine Tool Type Metrology Standard Type Metrology Enhanced Type Single Axis Type Linear Scale Exchanger SW-3000 series SW-4000 series DC-3000 series DC-5000 series WE-100
Product Description Sheet RB15 200D Gantry Robot Item No. 1670898
PRODUCT DESCRIPTION The Loctite has features and accessories that are custom tailored for adhesive dispensing processes. The gantry design configuration makes it ideal for integrating with automatic transfer
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
I/A Series HARDWARE Product Specifications
I/A Series HARDWARE Product Specifications PSS 21H-4U14 B4 V90 (Virtualization Server Host Hardware) The I/A Series Model V90 Server Virtualization Host is a Hewlett-Packard ProLiant DL380 rack mount server
ESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION
PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION 2.1 CHARACTER STRUCTURE 2.2 THE CHARACTER SET 2.3 CONTROL CHARACTERS 2.3.1 Transmission control
SCD Server. SCD Server Pro
SCD Server SCD Server Pro SCD Server & SCD Server Pro 9850-000387-01 - Page 1 of 8 SCD Server and SCD Server Pro The SCD Server is a 2U high DMX generator, running the ZerOS Operating System and emulating
OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED
6AV3607-1JC20-0AX1 Page 1 Product data sheet 6AV3607-1JC20-0AX1 OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED Supply voltage
DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8
DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8 V920 - PRODUCT DESCRIPTION Virtual Matrix Display Controller The Virtual Matrix Display Controller (VMDC) is a selfcontained, matrix control
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
Keep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
In-Sight Hardware specifications
specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited
Orbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4
Orbit PCI Mk 2 Network Card User Manual Part No. 502566 Issue 4 Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)