Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.
|
|
- Audrey Harvey
- 8 years ago
- Views:
Transcription
1 Motorized Actuators Motor Cables EZS /EZS for Clean Room Use This cable is a dedicated cable for connecting the linear slide of the EZS Series and EZS Series for Clean Room Use with the controller. Use the flexible extension cable in applications where the cable is bent and flexed repeatedly. (Cable is for both the electromagnetic brake type and without electromagnetic brake type.) Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2 CC020ES-2 CC030ES-2 3 m CC050ES-2 CC070ES-2 7 m CC100ES-2 10 m CC150ES-2 1 CC200ES-2 20 m Keep the cable length at 10 m or less for 24 VDC linear slides. Flexible Extension Cables (Without electromagnetic brake, with electromagnetic brake) CC010ESR-2 CC020ESR-2 CC030ESR-2 3 m CC050ESR-2 CC070ESR-2 7 m CC100ESR-2 10 m CC150ESR-2 1 CC200ESR-2 20 m Keep the cable length at 10 m or less for 24 VDC linear slides. CC ES-2/CC ESR Motor Side 8.28 ϕ9 Controller Side L Sensor Sets Sensor sets dedicated to the EZS Series and, EZS Series for Clean Room Use. The sensor set consists of three sets of a sensor, a sensor mounting bracket and a flexible sensor cable with connector () and 1 shielding plate. The screws needed for installation are also included. PAES-S PAES-SY Sensor Mounting Bracket 3 Pieces Shielding Plate 1 Piece Sensor Output NPN PNP Specifications NPN Type : EE-SX674A (OMRON) Power Supply 5 24 VDC±10%, Ripple (P-P) 10% max. Current Consumption 3A max. Control Output NPN Open-Collector Output, 5 24 VDC, 100 ma max. Residual Voltage 0.8 V max. (At load current of 100 ma) Logic Normally Open/Normally Closed (Selectable, depending on connection) Indicator LED Detection Display (Red) Sensor 3 Pieces Flexible Sensor Cable with Connector () 3 Pieces Conductor: AWG24 (0.m 2 ) PNP Type Power Supply Current Consumption Control Output Logic Indicator LED : EE-SX674R (OMRON) 5 24 VDC±10%, Ripple (P-P) 10% max. 30 ma max. PNP Open-Collector Output, 5 24 VDC, 50 ma max. Residual Voltage 1.3 V max. (At load current of 50 ma) Normally Open/Normally Closed (Selectable, depending on connection) Detection Display (Red) for Sensor Position LS Sensor Detection Position (When the LS sensor is used) Mechanical Stopper Position L2 21 L3 HOME Sensor Detection Position (When the HOME sensor is used) +LS Sensor Detection Position (When the +LS sensor is used) Stroke 21 Mechanical Stopper Position (When the HOME L5 L6 L7 sensor is used) L9 L10 L11 LS Sensor L1 21 L4 HOME Sensor +LS Sensor L8 Linear Slide Size L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 Note EZS EZS EZS If the stroke is 60 mm or below, all three sensors cannot be installed. E-98 ORIENTAL MOTOR GENERAL CATALOGUE
2 33.3 Connector Terminal Block Conversion Units Customer Support Centre Singapore: , Malaysia: , Others: These are conversion units that connect a linear motion controller to a sensor or programmable controller using a terminal block. Includes a signal name plate for easy, one-glance identification of signal names DIN-rail mountable Cable Length: Applicable Type Length CC20T1 For Sensor I/O Connector CC36T1 For I/O Connector CC20T1 B Terminal Block Pin No ϕ4.5 Mounting Hole 2 ϕ8 Counterbore 3.5 Deep DIN Rail Sensor Extension Cables These cables are for connecting the linear motion controller and sensor. CC20D1-1 CC20D CC36T1 B CC20T Terminal Block Pin No CC36T1 2 ϕ4.5 Mounting Hole 2 ϕ8 Counterbore 3.5 Deep DIN Rail Applicable Crimp Terminal Terminal Screw Size: M3 Tightening Torque: 1.2 N m Minimum Applicable Lead Wire: AWG22 (0.3 mm 2 ) Note Round terminals cannot be used. Conductor: AWG28 (0.08 mm 2 ) L 60± ϕ6.4 6.m max. Braided-Shielded 3.m min Pitch Laminate mm min. 4.m max. Motorized Actuators Introduction Types ELS EZS EZS Clean Room DRS DRL Motorized Linear Slides Motorized Cylinders Compact Linear Actuators ELC EZA DG Hollow Rotary Actuators Controller Side Sensor Side E-99
3 Motorized Actuators I/O Cables These cables are dedicated cables for connecting the linear motion controller and programmable controller. The cables are equipped with, at one end of the cable, a half-pitch connector for easy connection to the linear motion controller. CC36D1-1 CC36D2-1 Conductor: AWG28 (0.08 mm 2 ) 60±15 Braided-Shielded Pitch L Laminate Linear Motion Controller Side ϕ7.5 Programmable Controller Side Teaching Pendant The teaching pendant allows you to set and operate various data on hand, as well as to monitor the setting data, current position and I/O status in real time. EZT1 Specifications Display LCD with 2-Colored Backlight Cable Length Mass 0.37 kg Operating Ambient Temperature C (non-freezing) D (25) ϕ24.9 (1.5) Teaching Pendant ( EZT1)/ Data Editing Software (EZED2) Function Comparison Table Functions Teaching Pendant (: EZT1) Data Editing Software (: EZED2) Cable Length 1 Display LCD 17 characters 4 lines PC screen Emergency Stop Button Operation Data Setting Parameter Setting Teaching (Direct/Remote) Operating Data Monitoring I/O and Alarm History Monitoring Waveform Monitoring Test Operation Data Copy Printing Function 2 1 PC interface cable (included) is used 2 The printing function is not available on computers running Windows 98 and Me Teaching Pendant Cable ϕ ϕ11.2 E-100 ORIENTAL MOTOR GENERAL CATALOGUE
4 Data Editing Software Specifications (Operating environment) Customer Support Centre Singapore: , Malaysia: , Others: Various data can be set and edited on a personal computer. The software comes with a PC interface cable used to connect the linear motion controller with a computer. The software also provides various monitoring functions. EZED2 Ver 1.34 or later PC Interface Cable Cable Length PC Connector Type Communication Port Operating Softwares D sub 9-Pin One RS-232C Communication Port : EZED2 Microsoft Windows 2000 Professional Service Pack 4 or Later (Hereinafter, referred to as Windows 2000) Microsoft Windows XP Home Edition Service Pack 2 or Later (Hereinafter, referred to as Windows XP) Microsoft Windows XP Professional Edition Service Pack 2 or Later (Hereinafter, referred to as Windows XP) Microsoft Windows XP Media Center Edition 2004 Service Pack 2 or Later (Hereinafter, referred to as Windows XP) Microsoft Windows XP Media Center Edition 2005 Service Pack 2 or Later (Hereinafter, referred to as Windows XP) Microsoft Windows 98 Service Pack 1 or Later (Hereinafter, referred to as Windows 98) Microsoft Windows 98 Second Edition (Hereinafter, referred to as Windows 98) Microsoft Windows Millennium Edition (Hereinafter, referred to as Windows Me) Windows 2000: 128 MB min. (192 MB min. is recommended), Windows XP Home Edition or Professional Edition: 256 MB min. Memory Windows XP Media Center Edition 2004 or 2005: 320 MB min., Windows 98: 64 MB min. (128 MB min. is recommended) Windows 98 Second Edition: 64 MB min. (128 MB min. is recommended), Windows Me: 96 MB min. (160 MB min. is recommended) Computer Pentium 500 MHz or min. (OS must be supported) for Single Core and Processor Display Resolution Video Adapter and Monitor with Resolution of XGA ( ) min. Hard Disk Capacity Free Disk Space of 60 MB min. Serial Port RS-232C Port, 1 Channel Disk Device CD-ROM Drive Microsoft Internet Explorer 5.01 or later is also required. Service Pack indicates a service pack provided by Microsoft Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and other countries. Pentium is a registered trademark of Intel Corporation. Motorized Actuators Introduction Types ELS EZS EZS Clean Room DRS DRL Motorized Linear Slides Motorized Cylinders Compact Linear Actuators ELC EZA DG Hollow Rotary Actuators E-101
5 Motorized Actuators Battery Set This battery is required to use the controller in the absolute mode. A dedicated battery holder is included. PAEZ-BT2H Specifications Mass: 0.18 kg D488 (37.2) 31.5± (5) : PAEZ-BT2H Battery Type Cylindrical Sealed Nickel-Cadmium Cell Nominal Voltage 2.4 VDC Rated Capacity 2000 mah Mass 180 g Service Life Approx. 4 years Charge Time 48 hours 1 Data Retention Period Approx. 360 hours (approx. 15 days) 1 4 Operating Ambient Temperature C (non-freezing) Operating Ambient Humidity 20 85% 1 At an ambient temperature of 20 C 2 Calculated by assuming the following conditions of use (one-week cycle) The battery is charged for 8 hours and used for 16 hours to back up data on six days in a week. The battery is used to back up data for all 24 hours on one day in a week. 3 The battery is not charged at the time of shipment. Charge the battery for at least 48 hours before using it. 4 After the power is cut off with the battery fully charged 15 (2-R18.6) 60± ± ± (79.2) (8-R2.25) For protection of the environment, please recycle used batteries. Bring expended batteries to your nearest Oriental Motor sales office. DIN Rail Mounting Plate Use this mounting plate when installing the linear motion controller to a DIN rail. (The mounting screws are included.) PADP DIN Rail Mounting Plate 49 Center of DIN Rail Included Mounting Screws: M3P0.5 Length 8 mm 3 pieces included E-102 ORIENTAL MOTOR GENERAL CATALOGUE
6 Customer Support Centre Singapore: , Malaysia: , Others: Dual Axis Mounting Brackets (Applicable Products: EZS Series) These are dedicated mounting brackets for using two axes of the EZS Series motorized linear slides. X-Y Mounting X-Z Mounting Z-Axis Motorized Actuators Features Dual Axis Combinations Can be Easily Implemented in the EZS Series Using the dedicated mounting bracket allows you to easily use EZS Series motorized linear slides in dual axis combination. Various combinations are available such as X-Y or X-Z. Available Combinations of Products X-Y Mounting X-Z Mounting X-Axis Y-Axis Transportable Mass (kg) X-Axis Z-Axis Transportable Mass (kg) EZS4D EZS3D 2.3 max. EZS4D EZS3D 3.ax. EZS6D EZS3D 5.7 max. EZS6D EZS3D 3.ax. EZS6D EZS4D max. EZS6D EZS4D 6.7 max. The maximum length of a linear slide for the second axis (Y or Z axis) is 300 mm. This is applicable to products with a 1m lead. Speed is reduced by half for products with a 6 mm lead. Specification values are based on those when the X-axis is mounted horizontally. This is not a product suitable for a clean room environment. Product Number Code PAB - S4 S3 R Y-Axis X-Axis X-Axis You Can Select an Appropriate Size under Our Custom- Design Program "FACE" As with the EZS Series, the size of the dual axis mounting bracket is also specifiable in increments of 10 mm. Simple Streamlined Wiring with Dedicated Cable Holder (Cable holder sold separately) Dedicated cable holders are available. 1 Dual Axis Mounting Bracket 2 First Axis Side Linear Slide S4: EZS4D S6: EZS6D 3 Second Axis Linear Slide S3: EZS3D S4: EZS4D 4 Combination Patterns R: R Type L: L Type 5 Stroke in Second Axis First axis side refers to the X-axis, while second axis refers to the Y- or Z-axis. 50 mm increments Combination of EZS4 and EZS3 Combination of EZS6 and EZS3 Combination of EZS6 and EZS4 R Type L Type R Type L Type R Type L Type PAB-S4S3R005 PAB-S4S3L005 PAB-S6S3R005 PAB-S6S3L005 PAB-S6S4R005 PAB-S6S4L005 PAB-S4S3R010 PAB-S4S3L010 PAB-S6S3R010 PAB-S6S3L010 PAB-S6S4R010 PAB-S6S4L010 PAB-S4S3R015 PAB-S4S3L015 PAB-S6S3R015 PAB-S6S3L015 PAB-S6S4R015 PAB-S6S4L015 PAB-S4S3R020 PAB-S4S3L020 PAB-S6S3R020 PAB-S6S3L020 PAB-S6S4R020 PAB-S6S4L020 PAB-S4S3R025 PAB-S4S3L025 PAB-S6S3R025 PAB-S6S3L025 PAB-S6S4R025 PAB-S6S4L025 PAB-S4S3R030 PAB-S4S3L030 PAB-S6S3R030 PAB-S6S3L030 PAB-S6S4R030 PAB-S6S4L mm increments Custom-Design Program "FACE" Numbers Stroke Specifiable in the Box mm mm mm mm mm Custom-design program "FACE" Combination of EZS4 and EZS3 Combination of EZS6 and EZS3 Combination of EZS6 and EZS4 R Type L Type R Type L Type R Type L Type PAB-S4S3R PAB-S4S3L PAB-S6S3R PAB-S6S3L PAB-S6S4R PAB-S6S4L Introduction Types ELS EZS EZS Clean Room DRS DRL Motorized Linear Slides Motorized Cylinders Compact Linear Actuators ELC EZA DG Hollow Rotary Actuators E-103
g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP
Programmable Safety controllers g9sp G9SP compact Stand-Alone Programmable controller Stand-alone safety controller for small and mid-sized machinery Easy programming for complex safety control Three types
More informationCNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual
LaserProbe4500 CNC-STEP "LaserProbe4500" 3D laser scanning system Instruction manual 2 Hylewicz CNC-Technik Siemensstrasse 13-15 D-47608 Geldern Fon.: +49 (0) 2831 133236 E-Mail: info@cnc-step.com Website:
More informationSeries LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973
Series LCD To power supply Electric Actuator Series LCC Stepper Motor Driver LCD Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationColor Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationDescription. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationTilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology
Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range
More informationOrdering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
More informationResolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360
Absolute 60-mm-dia. Rotary Encoder CSM DS_E_7_ Rugged Rotary Encoder Absolute model. External diameter of 60 mm. Resolution of up to 1,024 (10-bit). IP65 oil-proof protection. Strong shaft. Radial: 120
More informationFlexible Counter Series in DIN size 24 x 48 mm
Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display 2 different supply voltages available: independent of mains supply with lithium battery
More informationLight Industrial Panel PC
Light Industrial Panel PC 7 ~15.6 Light Industrial Interactive Panel PC Features 7 ~15.6 light industrial interactive panel PC 9 V ~ 30 V wide range DC input with lockable DC jack Selectable AT/ATX power
More information2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationProgrammable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationAppearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C/25-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection via
More informationHF series Hall effect joysticks
Distinctive features and specifications 1, 2 & 3 axis configurations Dual sensors for redundancy CANbus J1939 and CANopen options Voltage regulator, 24V supply option USB 1.1 HID interface option ized
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationAppearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C10/15-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection
More informationSmart DeviceNet Remote I/O Terminals
Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems
More informationCruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationInductive Proximity Sensors
M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12
More informationHow To Power A Schen
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More informationMaterial: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More informationT-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
More informationEE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationM2M/IoT Solutions. www.contec.com
M2M/IoT Solutions www.contec.com M2M/IoT Solutions TM Hardware Highly Reliable M2M Controllers for Various Solutions M2M Controllers Compact design available on DIN rails Low-power design using a CPU tailored
More informationQR12 (1.22 ) Diameter Optical Encoder
Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions
More informationDifferential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationCAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.
7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND
More informationMultifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
More informationN20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL
N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,
More informationEncoders. the incremental encoders format such as relective optical technology, transmissive optical technology
the incremental encoders format such as relective optical technology, transmissive optical technology back devices, brakes and gearboxes at no extra cost to you. USA: +1 267 933 2105 Europe: +33 20928751
More informationOrbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4
Orbit PCI Mk 2 Network Card User Manual Part No. 502566 Issue 4 Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless
More informationSensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
More informationThree Channel Optical Incremental Encoder Modules Technical Data
Three Channel Optical Incremental Encoder Modules Technical Data HEDS-9040 HEDS-9140 Features Two Channel Quadrature Output with Index Pulse Resolution Up to 2000 CPR Counts Per Revolution Low Cost Easy
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
More informationVision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications
Vision OPLC V350-35-R34/V350-J-R34 Technical Specifications The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3
More informationProduct Discontinuation Notices
PRODUCT NEWS Product Discontinuation Notices Code Readers / OCR Issue Date March 2, 2015 No. 2015027CE Discontinuation Notice of 2D Code Reader (Fixed Type) V530-R160/R2000 series and the peripherals F150-[][][]-2D
More informationChapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
More informationX-axis Nut-rotation Type Cartesian Robot Assembly Procedures First Edition
X-axis Nut-rotation Type Cartesian Robot Assembly Procedures First Edition Thank you for purchasing an IAI product. Assemble your product correctly by referring to this Assembly Procedures. No. NS (nut-rotation
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationU-shaped Micro Photoelectric Sensor
SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even
More informationUSER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
More informationMounting HP Desktop Mini Rack Mount Tray Kit HP Desktop Mini Security/Dual VESA Sleeve
Mounting HP Desktop Mini Rack Mount Tray Kit HP Desktop Mini Security/Dual VESA Sleeve Optical Drive HP Desktop Mini DVD Super Multi-Writer ODD Expansion Module Input / Output / HDD HP Desktop Mini 500GB
More informationAir damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
More informationDCS Input/Output Relay Card Series
Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test
More informationProduct Description Sheet RB15 200D Gantry Robot Item No. 1670898
PRODUCT DESCRIPTION The Loctite has features and accessories that are custom tailored for adhesive dispensing processes. The gantry design configuration makes it ideal for integrating with automatic transfer
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationTemperature Datalogger Users Manual
Temperature Datalogger Users Manual Page 1 TABLE OF CONTENTS FEATURES & SPECIFICATIONS... 3 APPLICATIONS... 4 START UP AND GENERAL OPERATION... 5 LCD Display... 5 Turn On Temperature Data Logger... 6 Switch
More informationYamaha 01V96 Version2 Upgrade Guide
Yamaha 01V96 Version2 Upgrade Guide This document explains how to upgrade the 01V96 system software to V2.00 or later. Precautions (please be sure to read these precautions) The user assumes full responsibility
More informationThe quadrature signals and the index pulse are accessed through five 0.025 inch square pins located on 0.1 inch centers.
Quick Assembly Two and Three Channel Optical Encoders Technical Data HEDM-550x/560x HEDS-550x/554x HEDS-560x/564x Features Two Channel Quadrature Output with Optional Index Pulse Quick and Easy Assembly
More informationLM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs
857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~
More informationALARM SYSTEM PLC. MODICON 984 - A120 Description. 01 September 2000 ASI GmbH B. Dittmer LADESTRASSE 3-3A 28197 BREMEN
ALARM SYSTEM PLC MODICON 984 - A120 Description 01 September 2000 ASI GmbH B. Dittmer LADESTRASSE 3-3A 28197 BREMEN Alarm System PLC 984 - A120, Sheet 2 1. Compact Hardware The Alarm- and Monitoring System,
More informationBall Rail Tables TKK. with Ball Rail Systems and Ball Screw Drive R310EN 2501 (2008.04) The Drive & Control Company
with Ball Rail Systems and Ball Screw Drive R310EN 2501 (2008.04) The Drive & Control Company Bosch Rexroth AG Linear Motion and Assembly Technologies Ball Rail Systems Roller Rail Systems Linear Bushings
More informationPhidgetInterfaceKit 8/8/8
PhidgetInterfaceKit 8/8/8 Operating Systems: Windows 2000/XP/Vista, Windows CE, Linux, and Mac OS X Application Programming Interfaces (APIs): Visual Basic, VB.NET, C, C++, C#, Flash 9, Flex, Java, LabVIEW,
More informationSmall-diameter Proximity Sensor
Small-diameter Proximity Sensor EE Ultra small size, but surprisingly easy installation! With the addition of M,.-dia. size, unshielded, pre-wired connector model, and connector model, a total of 0 model
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationSCARA ROBOT TH SERIES
Wide Variations, Fast Motion, and Heavy Duty SCARA ROBOT TH SERIES Compact SCARA Robot High-Speed and High-Precision SCARA Robot High Payload Mass SCARA Robot TH180, TH250A, TH350A TH450, TH550 TH650A,
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationAFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55. 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor with HM55 chipset
AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor with HM55 chipset AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor
More informationBrushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51
DC Input BLH Series Brushless DC Motors Intro duction BLF BLU BLH Installation C Input DC Input Page BLH Series B-52 B-51 RoHS-Compliant Brushless DC Motor and Package BLH Series The BLH Series combines
More informationPT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February 2006. Specifications subject to change without notice.
Product Number : Product Name : As of February 2006. Specifications subject to change without notice. < > Specifications Power supply Power consumption Optical system CD panel Panel size Display method
More informationE3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity
Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,
More informationUser Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationStepper Motor and Driver Package AZ Series Equipped with Battery-Free Absolute Sensor ADVANCED
Z DVNCED Z Z PS HPG Z TS DVNCED 3 Z BZO MEXE Z Z 6 Z Z Z 7 Z66C Z66C 1 8 6 Z66C 8 MEXE MEXE MEXE 9 Z MEXE MEXE MEXE 1 11 Z DG TS PS HPG ES Z EZS Z EC Z Z TS PS HPG TS PS HPG "System Configuration Built-in
More informationFrequency selective monitoring and logging of environmental electromagnetic fields
FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
More informationRosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More information2M IR Mini Dome Quick Installation Guide
2M IR Mini Dome 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationSystem Configuration and Order-information Guide ECONEL 100 S2. March 2009
System Configuration and Orderinformation Guide ECONEL 100 S2 March 2009 Front View DVDROM Drive 5 inch Bay Floppy Disk Drive Back View Mouse Keyboard Serial Port Display 10/100/1000BASET Connector Inside
More informationSeries 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
More informationSWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
More informationFeatures. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)
Features Excellent C/P ratio (cost/performance) High-resolution color touch screen RTC (Real Time Clock) Supports 1 Serial Port (RS-232/RS-485, including Self-Tuner) Rubber Keypad WYSIWYG (What You See
More informationProducts. Air Bearing- Linear systems 06-2009 EITZENBERGER. Luftlagertechnik GmbH. Feichtmayrstraße 17 D-82405 Wessobrunn
Products Air Bearing- Linear systems 06-2009 ITZNBRGR D- mail: URL. Index - Air Bearing linear Systems Z 0526 Air Bearing Linear Stage with high resolution encoder and iron free linear motor Z 0512 XY-Air
More informationSeries LC1 Dedicated Controller for Standard AC Servomotor LJ1 Electric Actuator LG1 Teaching Box LTF
Series LC Dedicated Controller for Standard AC Servomotor Electric Actuator Teaching Box PC (Not incl. To be provided by customer.) LJ LG LC Power supply Controller Setup Software LC6 LZ PLC/ Positioning
More informationSpecifications for the Gateway M1300 Tablet PC
Specifications for the Gateway M1300 Tablet PC Specifications are subject to change without notice or obligation. Processor and Core Logic Processor options Chipset Processor packaging Level 2 cache Core
More informationPC Software Operating Manual
RCB-101-MW PC Software Operating Manual 9th Edition Software License Agreement Before opening this product, read the software license agreement (hereinafter referred to as Agreement ). This Agreement applies
More informationLENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space
PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning
More informationRosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
More informationShutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
More information