INSTALLATION INSTRUCTION



Similar documents
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

T-100-R Installation Guide

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

SECTION HEAT PUMPS

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Digi-Motor Installation Guide

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

OPL BASIC. Dosing System for Professional Laundry machines. Contents

E2 Series Electric Furnaces

Installation Instructions

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Your safety and the safety of others are very important.

INSTALLER S & OWNER S MANUAL

ACS-30-EU-EMDR-10-MOD

i ChatterBox! Motorcycle Security

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Powers Controls TH 192 S Single Temperature Room Thermostat

Installation Instructions

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

, User s Manual

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

FOXAIR 60/50 ALL MODELS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Telefon (+45) Telefax (+45) Installation and operating manual

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

A/C-HEATER SYSTEM - AUTOMATIC

HERZ-Thermal Actuators

Model 201 Wiegand Touchpad Reader Installation Guide

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

T7079A,B Solid State Remote Temperature Controllers

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Failure code manual. content

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

INSTALLER'S GUIDE. Supplementary Electric Heaters 18-GJ08D1-1. Table of Contents

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Research RF Sputtering Packages

1R / 4-BUTTON SERIES

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

Cooktop Low-Profile Ventilation Hoods

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Air Conditioning System


POWER WAVE 455M/STT & (CE)

Cooling Capacity CFM in. w.c. (125 Pa)

TYPE. MODEL B3200 Roof-Top Air Conditioner used with Mechanical Air Distribution Box INSTALLATION & OPERATING INSTRUCTIONS Air Conditioner

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

TS93 EMR T/PT/TDE. Surface applied door closer

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

HEAT HEAT COOL HEAT PUMP COOL


ECM Blower Motor Replacement Controls Programming Process

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Part Number:

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

K9 Heat Alarm Owners Manual HA-1520

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

WHITE-RODGERS COMFORT-SET 90 SERIES

Technical Information

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

INSTALLATION & OPERATING INSTRUCTIONS

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

SLIM LINE FUME HOOD MONITOR

Pro Logic Version Diagnostics Manual

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

Control Box Wiring For PRSstandard Tool

Cooling Capacity CFM in. w.c. (125 Pa)

Transcription:

FORM# 571C-0411 (571C-0610) I - SHIP PING AND PACK ING LIST Package 1 of 1 contains: 1 - Economizer Assembly 1 - Fresh Air Hood w/ Filter 1 - Control Package 1 - Barometric Relief Hood 1 - Filter Access Panel 2 - Wire Nut (For Mixed Air Sensor) 16 - #10 x ½ x 16 Hex Tec Check contents for shipping damage. Contact the last carrier immediately if any shipping damage is found. ENTHALPY SENSOR DAMPER MOTOR CONTROL PACKAGE (STEP 3) II - APPLICATION Figure 1 Economizers are used with Q5SN/Q6SP/P6/R6 units for automatic sensor-controlled introduction of outdoor air into the system through an electro-mechanically controlled damper. Outdoor air is mixed with the buildings return air to economically improve indoor air quality and aide in reducing energy costs. Economizer slides into horizontal return air opening. Mixed air sensor, TB11, and enthalpy control board relay are shipped in economizer and must be relocated to the unit's filter section. Intake and exhaust hoods are packaged with economizers and installed according to instructions below. III - ECONOMIZER IN STAL LA TION 1. Disconnect all power to unit. 2. Cut and discard wire tie securing wire bundle to the damper motor Important - DO NOT cut other wires. Inspect for damaged connections or loose wires. 3. Remove box of controls to be installed over the assembly containing the logic control board and mixed air sensor. See Figure 1. 4. Remove from box the logic control board and wire bundle. Cut wire tie securing the bundle of wires to logic control board and mixed air sensor. 5. Locate S1, the unit's economizer connection and remove the installed dummy plug. See Figure 3. 6. Connect economizer jack S2 to economizer plug P2 on the economizer assembly. 7. Route wiring to the right side of the economizer and slide it into the unit. Insert economizer side flanges into the unit standing seams. Using existing screws from bottom of discarded panel to secure economizer bottom flange to unit. See Figure 2. MULLIONS INSERT THE SIDE FLANGES INTO THE UNIT STANDING SEAMS RETURN AIR OPENING Figure 2 1

8. Position logic control board in filter access area as shown in Figure 3. Secure control board with two #10-16 x ½ screws. 9. Insert mixed air sensor tube through the mounting hole into the supply air compartment. Secure using two #10-16 x ½ screws. See Figure 3. 10. Connect economizer plug P1 to unit jack S1 on units economizer control panel. 11. Verify that wire harnesses are secure and will not interfere with economizer vane and linkage operation, or with a filter change out Note: Leave unit dummy plug (from Step 5) in the unit control panel for later use if the economizer needs to be by passed. TB11 BOARD AND LOGIC CON TROL MIXED AIR SENSOR S1 UNIT JACK FILTERS INTAKE AIR ENTHALPY SENSOR EXHAUST AIR DAMPER MOTOR Figure 3 FRESH AIR HOOD BAROMETRIC RELIEF HOOD FILTER ACCESS DOWN FLOW APPLICATION 12. Install barometric relief hood in front of exhaust air opening. 13. Install fresh air hood in front of intake opening. 14. Slide filter access panel underneath top of unit and secure to mullions. a. For heatpump units refer to Section IV before restoring the unit power. 15. Restore power to unit and check for proper damper operation (See System Check section). Figure 4 SCREW TO SIDE MULLIONS NOTE: 2 FRESH AIR HOOD Figure 5 FOR THIS APPLICATION, HORIZONTAL DUCT KIT #547881 IS REQUIRED. SUPPLY DUCT 30 x 16 3 8 RETURN DUCT 31 x 18 ¾ CUT HOLE - 31" x 18 3 8 FILTER ACCESS BAROMETRIC RELIEF HOOD HORIZONTAL APPLICATION 12. Install barometric relief hood to return duct over the opening in duct. 13. Install fresh air hood in front of intake opening. 14. Slide filter access panel underneath top of unit and secure to mullions. a. For heatpump units refer to Section IV before restoring the unit power. 15. Restore power to unit and check for proper damper operation (See System Check section).

IV HEAT PUMP SET UP PRO CE DURES A. Q5SN Series Notice to Installer: Proper operation of this economizer when used on Q5SN Series 7.5 and 10 Ton Package Heat Pump systems is dependent on the type thermostat installed with the unit. Identify which type thermostat is connected to unit before making any wiring changes if needed. Ther mo stat Type 1 Sep a rate "O" and "B" ter mi nals for se lect ing Re vers ing Valve Con trol Q5SN Series Heat Pump units are factory pre-wired for economizers connected in conjunction with a 2 Stage Heat / 2 Stage Cool thermostat that utilize the "O" terminal to energize the reversing valve(s) when the thermostat "System Switch" is set in the "Cool" mode and has a separate "B" terminal supplied with 24 VAC when the thermostat "System Switch" is in the Off, Heat, or Emergency Heat mode. With "B" energized the economizer is automatically locked out during heating operation. It holds the outdoor fresh air damper at the minimum position setting only. Ther mo stat Type 2 Sin gle "O/B" ter mi nal for se lect ing Re vers ing Valve Con trol If the thermostat has only one terminal, "O/B", for determining if Heat or Cool mode energizes the Reversing Valve(s), the following heat pump unit low voltage wiring changes MUST be made: (Refer to the unit wiring diagram for identification) 1. DISCONNECT MAIN POWER TO THE UNIT. 2. Thermostat - Select the "Cool" mode to energize the Heat Pump unit s reversing valve(s). 3. Heat Pump Relay - Located to the left of the Defrost Board in the unit s main control panel. Reverse connections of the Orange and Yellow wires on Heat Pump Relay terminals 1 and 4. Reverse connections of the White and Blue wires on Heat Pump Relay terminals 3 and 6. 4. Low Voltage Terminal Board - Jumper "O" and "B" terminals. Located in the Electric Heat Section of unit. B. Q6SP Series The Q6SP Series heatpumps are factory wired for use with an"o" terminal that is energized in cooling mode. These units do not require or utilize a "B" terminal signal. Do not alter the factory wiring of the Q6SP units for use with this economizer V - SYS TEM CHECK AND START UP PRO CE DURES 1. Disconnect main power to unit. 2. Install jumper on auxiliary contacts of blower contactor in main unit control box. 3. Turn thermostat control to OFF position. 4. Install jumper on damper motor terminals T and T1. See Figure 8. 5. Restore power to unit. Damper should drive to fully opened position (requires 1 ½ minutes for full travel). Observe travel for proper damper operation. 6. Disconnect power to unit. Damper should spring return to closed position. 7. Remove T and T1 jumper on damper motor, then restore power to unit. Adjust minimum vent position on potentiometer on damper motor. See Figure 8. 8. Set the outdoor air enthalpy change overpoint. Refer to Figure 6 and the instructions on Page 4. 9. Disconnect power to unit and remove jumper on auxiliary contacts of blower contactor in main unit control box. Restore power to unit. 10. Set the minimum damper position. See instructions on Page 5 and 6 and the chart on the last page. VI - MAIN TE NANCE 1. Damper motor is prelubricated and does not require further lubrication. 2. Make visual inspection of dampers and linkage assemblies during routine maintenance. 3. Filters should be checked periodically and cleaned when necessary. 4. The washable filters supplied with the economizer can be cleaned with water and a mild detergent. 5. Take note of "Air Flow Direction" marking on filter frame when reinstalling. 6. If filter must be replaced, filter of like kind and size must be used. DO NOT replace permanent filters with throwaway type filters. 3

Figure 6 OPERATION A. Cooling Mode 1. On a call for cooling, with ambient temperature and humidity above enthalpy control setpoint, damper will open to minimum vent position. 2. On a call for cooling, with ambient temperature and humidity suitable for cooling, enthalpy control will shift stage one control to outside air and shift stage two thermostat to first stage compressor. Damper will modulate to control supply air temperature at 55 F (13 C). If additional cooling is required, compressor one may be energized through second stage of thermostat. B. Heating Mode 1. On a call for heat damper will open to the minimum vent position only. Set ting the Out door Enthalpy Change over Point The enthalpy control senses both temperature and humidity or the heat content of the outside air. It controls the amount of outdoor air brought into the system. When the heat content of the outside air is below control setpoint, the control modulates outdoor dampers to meet cooling needs of the building. When the heat content rises above control setpoint, the control closes outdoor dampers to minimum position. The recommended setpoint is A. If Economizer is allowing air which is too warm or too humid to enter the system, control may be changed to a lower setpoint (B, C, or D). Refer to Figure 6. Differential Enthalpy Settings For units equipped with a differential enthalpy sensor, refer to the instructions include in the 920233 accessory kit. 4

Adjusting Minimum Damper Position The minimum position potentiometer keeps outdoor air damper from closing completely during system operation to provide ventilation. Minimum Position Adjustment W7459A 1. Disconnect mixed air sensor from terminals T and T1. 2. Make sure either factory-installed jumper is in place across terminals P and P1 or if remote damper positioner is required, that it is wired according to Figure 7 and turned fully clockwise. 3. Connect 24 Vac across terminals TR and TR1. 4. Adjust potentiometer on face of W7459 with screwdriver to desired minimum position. Optional Applications Remote Minimum Position Control Remote control of outdoor air dampers is desirable when potential exists for temporary additional ventilation. The potentiometer in W7459 controls damper minimum position. Adding S963B1128 Remote Manual Potentiometer allows occupants to open dampers beyond minimum position for additional ventilation. Connect potentiometer as shown in Figure 7. This chart can also be used for measuring the percentage of outside air on an air handler. The same three temperatures are measured per the formulas on the preceding page. Lines are drawn on the chart using a ruler. As with the formulas this chart is most effective if there is at least a 10 degree F difference between the return and outside air. This will typically require either a warm or cold day rather than moderate weather. It is more accurate to measure outside air percentage on a day when the outside temperature is 10 F (-12 C) rather than on a day when it is 70 F (21 C). If the temperature difference between the return and outside air is only a few degrees, a small error in measurements can alter the results by as much as 50% using this method. If the temperature difference is 40 or 50 F (22 or 28 C) small errors in measurement do not substantially affect the results of the calculations. A full size chart is provided on the last page of these instructions. For detailed instructions on the use of this chart, refer to Honeywell publication # 63-8594, Honeywell Economizers. Pages 12-13. Figure 7 S963B1128 Remote Minimum Position Potentiometer used with W7459 for remote damper control. Re turn Air Tem per a ture + % of Outside Air % Re turn Air Tem per a ture of x x Outside Air = Formula for Adjusting the Minimum Position Control Tem per a ture of Mixed Air For design requirements for CFM per person for all building types, refer to ASHRAE standard 62.1 section 6 and/or local or state building codes. 5

1. Measure the return air temperature. 2. Measure the outside air temperature. 3. Draw a line from the return air temperature to the outside air temperature. 4. Measure the mixed air temperature in multiple locations and determine the average. 5. Draw a line down from the mixed air temperature to the point where it intersects the first line. 6. Draw a line from the point of intersection to the outside air percentage on the left side of the chart. According to the results from this chart this air handler is supplied with 26% outside air. If the total supply volume is 20,000 cubic feet per minute (cfm) (566 m 3 /min) then: 0.26 X 20,000 cfm of total supply air equals 5,200 cfm of outside air (147 m 3 /min). This indicates that when the measurements were done on this air handler the total volume of outside air in the mixed air was 5,200 cfm of outside air (147 m 3 /min). 6

CHECK OUT AND TROU BLE SHOOT ING Check the W7459 for proper operation. Table 1 describe how to simulate various environmental conditions. Make necessary minor adjustments to the minimum position until desired operation is obtained. If the economizer system does not operate properly, check individual components of the system according to the instructions provided with each device. If the other components operate properly when disconnected from the W7459, but the system (as a whole) does not, replace the W7459. Checkout Procedure Proper Response 1. a. Dis con nect power at TR and TR1. ---- b. Dis con nect Jumper P to P1. c. Jumper TR to 1. d. Jumper T1 to T. e. If con nected, re move C7400 Solid State LED is off. Enthalpy Sen sor from ter mi nals S O and +. Ensure factory-installed 620 ohm resistor is connected to terminals S R and +. f. Apply power (24 Vac) to terminals TR and TR1. Motor is in closed position. 2. a. Disconnect factory-installed 620 ohm resistor from terminals S R and +. 3. a. To simulate high and low enthalpy (single ---- enthalpy sensor), reconnect factory- installed 620 ohm resistor from terminals S R and +. Connect 1.2K ohm 4074EJM Checkout Resistor across terminals S O and + LED turns on (A model only, for D model, go to step 3). Motor drives toward open. b. Turn enthalpy setpoint potentiometer to "A". LED turns on, indicating low enthalpy. Motor drives toward open. c. Turn enthalpy setpoint potentiometer to "D". LED turns on, indicating high enthalpy. Motor drives toward closed. d. Disconnect the 1.2K ohm checkout resistor. ---- 4. a. To verify sensor operation, reconnect the + lead ---- of outdoor enthalpy sensor to the + terminal of W7459 b. Connect a DC milliammeter between terminal Milliammeter indication is between 3 and S O of the W7459A and terminal S of the 25 ma if sensor is operating properly. enthalpy sensor. (Positive meter lead to If milliammeter indicates zero, the sensor terminal S of the enthalpy sensor.) may be wired backwards. c. When using differential enthalpy, check the Milliammeter indication is between 3 and return air enthalpy sensor by connecting a DC 25 ma if sensor is operating properly. milliammeter between terminal S R of the If milliammeter indicates zero, the sensor W7459A and terminal S of the return air may be wired backwards enthalpy sensor. (Positive meter lead to terminal S of the enthalpy sensor.) Figure 8 - M7415A Figure 9 - W7459A DAMPER ACTUATOR 7

C7046C Air Temperature Sensors resistance versus temperature. Approximate dimensions of C7046C Air Temperature Sensor in in. (mm). C7400A Sensor output current vs. relative humidity Approximate dimensions of C7400A Solid State Enthalpy Sensor C7650A Solid State Temperature Sensor in in. (mm) 8

CONNECTOR & CONTACT CONFIGURATION P1 - (303908) PLUG & (303912) PIN S2/P2 - (303903/303904) CAP/PLUG & (303913/303912) SOCKET/PIN See Unit Wiring Diagram for Connections at S1 HARNESS DETAIL E# = WIRE END DESIGNATION E2 STUD #6 18 Ga. Wire E3 Female ¼ Quick Disc. E4 Male ¼ Quick Disc. Insul E6 Wire Nut Size 73B HAR NESS ENDS AT (P1) ECONO MIZER PLUG COMPONENT CODE C7046C Mixed Air Sensor C7400A Fresh Air Sensor M7415A Damper Actuator 24V P1/S1 Plug/Cap Economizer P2/S2 Plug/Cap Economizer TB-11 Terminal Board W7459A Logic Module WIRE COLOR CODE BLK Black BLU Blue BRN Brown GRN Green ORN Orange RED Red VIO Violet WHT White YEL Yellow Revision Change Date A Changed mixed air sensor 11-07-07 B Changed wire lengths 06-07-10 C Added S2/P2 plugs back in 06-18-10 Notes: 1. Y2 must be en er gized for Stage 1 com pres sor to op er ate dur ing economizer op er a tion. 2. Re lays 1K and 2K ac tu ate when the out door air enthalpy is higher than the enthalpy set point A-D on the the W7459A Logic Mod ule. 3. 1S is an elec tronic switch which closes when pow ered by a 24 VAC in put. 4. Fac tory in stalled 620 Ohm, 1 Watt, 5% re sis tor should be re moved only when a sec ond C7400 Enthalpy Sen sor is added to SR and + for dif fer en tial enthalpy con trol. Mod u lat ing Economizer Q5SN / Q6SP 090-120 P6 / R6 120 () Date: June 22, 2010 Supersedes: 06-07-10 Drawn by: MGL Unit #: 47-314-11 Diagram#: 4731411W Approved by:

INSTALLATION Outside Air Percentage Chart SUPERSEDES 06-21-10 MAY 18, 2011 NEIEC11 10