PLUMBING FIXTURES GUIDELINES



Similar documents
BUILDING CODE MANUAL COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS BUILDING AND SAFETY DIVISION

Revised: Previously Issued As: P/BC PLUMBING FIXTURES

CHAPTER 29 PLUMBING SYSTEMS. [P] TABLE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES a (See Sections and ) 1 per 40 for the

CHAPTER 29 PLUMBING SYSTEMS

How To Calculate Fixture Counts For A Building

BUILDING CODE MANUAL COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS BUILDING AND SAFETY DIVISION Based on the 2014 LACBC

City of Riverside Building & Safety Division Phone: (951)

Chapter PLUMBING CODE

9770 CULVER BOULEVARD CULVER CITY, CA Incidental improvements: improvements that do not qualify as minor or

Utility Service Application

(1) (a) through (1) (e) (iv) Remain the same.

Commercial Fee estimate The Building department will provide the actual fees at the time the permit is issued.

New York City Department of Buildings

Water Use Reduction Additional Guidance

ADA Scoping: New Construction

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:

Schedule B to By-law

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

BUSINESS USE PERMIT APPLICATION

INSTALLATION OF WATER-CONSERVING PLUMBING FIXTURES SB 407 California Civil Code Section Green Building Standards Code

BOARD OF EDUCATION Attachment: Discussion 10. PALO ALTO UNIFIED SCHOOL DISTRICT Date:

CHAPTER 2: The Plumbing System

Plumbing Fixture Replacement (SB 407) for Existing Single-Family Residential, Multifamily Residential and Commercial Buildings

Table PARKING SPACE RATES AND PARKING SPACE OCCUPANCY

ACCESSIBILITY CHAPTER 11

SIZING OF WATER PIPING SYSTEM

Schedule B to By-law Part A Fees Payable for Permits

Highway Requirements Part 4

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

One of the fundamental design elements that every

Guideline for Implementation of California Civil Code Sections Water-Conserving Plumbing Fixtures

Facilities Operations Customer Service Standards WORK ORDER PRIORITIES

CONSTRUCTION PERMIT APPLICATION AND INSTRUCTIONS (Permit Application follows instructions)


Plumbing Code Sections For Commercial Food Facilities

Contact: Michelle Benson

2010 ADA Standards for Accessible Design. Department of Justice

CITY OF YORBA LINDA P.O. BOX CALIFORNIA

2016 BUILDING PERMIT FEES*

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Guidelines for Remodeling and Additions with Respect to On-site Wastewater Treatment Systems

Electrical Contractors. and the. New Jersey. Rehabilitation Code

Measurement Standards for Structures

Plumbing Code Statutes and Regulations February 2011 Labor Standards and Safety Division Mechanical Inspection

WATER & SEWER SERVICES

SECTION THREE CONSTRUCTION CODES

Event & Sports Marketing Partnership Programs - Haymarket SportsPlex

HOW TO START A COFFEE SHOP IN PHILADELPHIA

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

APPLICATION FOR NEW CONSTRUCTION

Commercial Energy Use Worksheet

REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

Typical storey plan with two toilet clusters SANITARY PROVISION SANITARY PROVISION. Individual washroom. Standalone, unisex individual washroom

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION

RESIDENTIAL WINDOW REPLACEMENT

Isometric Plumbing Drawings

MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

CITY OF BAY CITY ORDINANCE NO. 628

city of edmonds development information

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

2006 IBC BUILDING CODE CHECKLIST FOR COMMERCIAL PROJECTS

CITY OF CHICAGO DEPARTMENT OF BUILDINGS RULES AND REGULATIONS for CERTIFICATES OF OCCUPANCY

The Raleigh Convention Center Raleigh, North Carolina Green Building Education A Self Guided Walking Tour

ADA Design Guide Washrooms & Showers

Editorial Note: bold and underline denotes added text, strikethrough denotes deleted text

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

KBC Chapter 34 : Applying the Kentucky Building Code to Existing and Historic Buildings

The New Realities of Water Recycling in San Francisco

City of Riverside. Building & Safety Division Phone: (951)

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

MEMPHIS FACT SHEET TOURISM STATISTICS

How To Build A Basement House

Saint Cloud Business Center

PLUMBING ROUGH IN INSPECTION

CHAPTER 4 VENTILATION

COUNTY OF LOS ANGELES BUILDING AND SAFETY DIVISION ELECTRICAL CODE FEE SCHEDULE (Title 27 of the County of Los Angeles Code, Ord No.

TENT AND STAGE CUSTOMER ASSISTANCE GUIDE

Accessibility Guide for Small Businesses

Building Permit, Fire Inspection and Operating Permit Fee Schedule

Applies to: All Employees within the Facilities Management Department (FMD)

Transcription:

COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS BUILDING & SAFETY DIVISION 2902 BUILDING CODE MANUAL Article 3 12-20-02 Page 1 of 6 PLUMBING FIXTURES GUIDELINES The following policy establishes guidelines which are intended to develop minimum number of plumbing fixtures for various occupancies. This guideline was developed in conjunction with the Los Angeles Regional Uniform Code Program (LARUCP) and covers new construction, as well as additions and alterations. The procedures outlined in this BCM are to be used by the building plan check engineers to determine the required number of plumbing fixtures. According to Section 2901 of the Los Angeles County Building Code(LACBC), all plumbing systems shall comply with the Los Angeles County Plumbing Code (LACPC). The LACPC Tables 4-1, 4-2, 4-3, and 4-4 shall be used in determining the required number of plumbing fixtures. Table 4-1 applies to all occupancies, while the remaining tables apply to the specific occupancies governed by the adopting State Agencies. (See Matrix Adoption Tables in the LACPC) For occupancies not listed in Table 4-1, the number of required plumbing fixtures shall be determined by the Administrative Authority, as stated in Section 413.4.3 of the LACPC. In determining the required number of plumbing fixtures, the footnotes under item F below shall always be considered. A. New Buildings A. Calculate the occupant load using Table 10-A of the 2002 LACBC. B. Determine the required number of fixtures using the appropriate LACPC tables. B. Existing Buildings A. Change of Occupancy shall be treated as a new building. B. Additions and Alterations which increase the existing occupant load, may use one of the following options: Option I Calculate the occupant load of the addition or altered area (Table 10-A LACBC). Determine the required number of fixtures using the applicable table in LACPC. Provide the required number of fixtures within the addition or altered area. The required number of new fixtures may be located in a common area

2902 Article 3 Page 2 of 6 within the existing building as long as the common area is accessible to and from the addition or altered area. Option II Calculate the occupant load of the existing building (Table 10-A LACBC). Determine the required number of fixtures from the applicable table in LACPC. Calculate the total occupant load for both the existing building and the addition, or alteration (Table 10-A LACBC). Determine the required number of fixtures from the applicable table in LACPC. Subtract the number of required existing fixtures from the number of required existing plus the addition or alteration fixtures. The difference is the required number of additional fixtures. Option III Calculate the occupant load of the addition or alteration (Table 10-A LACBC). Determine the number of fixtures from the applicable table in LACPC. Determine the number of fixtures that was required for the existing building based on the Building Code under which the building was permitted. Subtract the number of required fixtures of the existing building from the actual number of fixtures of the existing building. Credit the difference to the number of fixtures required for the addition or alteration and provide additional required fixtures if needed. C. Alterations that do not increase the occupant load and are not a change in occupancy classification but may be a change in use, may maintain their existing nonconforming rights. D. Relocated Buildings shall be treated as new buildings. E. The following guideline for occupancies not included in Table 4-1 of LACPC shall be considered: 1. Retail spaces, markets, and wholesale stores Use 200 square feet per occupant to determine the occupant load for use in the following chart: Type of Building Water Closets* (fixtures per persons) Lavatories (fixtures per person)

2902 Article 3 Page 3 of 6 Male Female Male Female Retail, markets, or wholesale stores 1 : 1-50 3 : 101-400 1 : 1-50 3 : 101-200 4 : 201-300 5 : 301-400 One for each two water closets over 400, add one fixture for each additional 500 males and one for each 150 females. *Where urinals are provided, one water closet less than the number specified may be provided for each urinal installed, except the number of water closets in such cases shall not be reduced to less than two-thirds (2/3) of the minimum specified. 2. Hotels and Motels Minimum required bathroom facilities at lobby area shall be one toilet facility for each sex. For lounge, bar, and restaurant areas, determine occupant load based on Table 10-A of LACBC and calculate the required number of plumbing fixtures using Table 4-1 of LACPC. Hotel guest rooms are required to have one toilet facility. For conference rooms, ballrooms, meeting and gathering areas, determine the occupant load (OL) based on Table 10-A of LACBC. If OL is fifty (50) or more, use assembly places category of Table 4-1 of LACPC to determine the number of plumbing fixtures, otherwise, use office or public buildings category of Table 4-1. 3. Warehouses and Storage Buildings Table 10-A of LACBC usually yields high number of occupant load for these categories. If submitted plans show fixed rack structures, machinery, equipment, etc. on the floor plans, the plan check engineers may deduct the footprint of these elements from the gross floor area and calculate the occupant load based on Table 10-A of LACBC items No. 20, 26, and 29 respectively. Consequently, a determination of the number of plumbing fixtures is performed by using Table 4-1 of LACPC Industrial Warehouses category. 4. Self Service Laundromats The occupant load is determined by either using 30 square feet per occupant based on the gross floor area or based on the total number of washers and dryers by counting one occupant for every two machines (either a washer or a dryer). The number of plumbing fixtures is determined based on the chart below.

2902 Article 3 Page 4 of 6 Regardless of the occupant load, facilities with a total floor area of 1500 square feet or less need only provide a unisex toilet facility designed for use by both sexes. Type of Building Water Closets* (fixtures per persons) Lavatories (fixtures per person) Male Female Male Female Laundromats 1 : 1-50 3 : 101-400 1 : 1-50 3 : 101-200 4 : 201-300 5 : 301-400 One for each two water closets over 400, add one fixture for each additional 500 males and one for each 150 females. *Where urinals are provided, one water closet less than the number specified may be provided for each urinal installed, except the number of water closets in such cases shall not be reduced to less than two-thirds (2/3) of the minimum specified. 5. Sport Facilities Sport facilities may be used for other events (i.e. concerts, shows, ceremonies, etc.). To determine the proper occupant load, the use of the facility shall be defined at the time of plan submittal. The following guidelines shall be used to determine required number of plumbing fixtures. a. Facility is used only for sport activities Facility with fixed seating: Calculate the occupant load based on Section 1003.2.2.2.3 of LACBC and determine the number of plumbing fixtures according to Table 4-1 of LACPC under assembly places for public use. Number of toilet fixtures for designated employee and player arenas shall be determined based on type of occupancies using Table 10-A of LACBC and utilizing Table 4-1 of LACPC. Facility without fixed seating: Calculate the occupant load for the event area based on Table 10-A of LACBC and determine the number of plumbing fixtures according to Table 4-1 of LACPC under assembly places for public use. The number of toilet fixtures for designated employees and player arenas shall be determined based on occupancy groups using both Table 10-A of LACBC (use an occupant load factor of 50) and Table 4-1 of LACPC. b. Facility used for sport activities and other events If the center court or other areas in the facility is used for special events and/or labeled as multi-purpose room, an additional occupant load for these areas shall be determined based on a mutual agreement between the

2902 Article 3 Page 5 of 6 applicant, Building Plan Check Section, and Fire Department. This additional load shall be added to the numbers calculated in Section E.5.a. 6. Shell Buildings The following guidelines shall be used to determine the number of plumbing fixtures and the size of sewer and water lines required: II. III. IV. Calculate the occupant load based on the gross floor area and the projected use and occupancy of the building using Table 10-A of the 2001 LACBC. Determine the required number of fixtures using the appropriate LACPC tables. Although restrooms need not to be shown on floor plans, a determination of the size of sewer and water lines based on the total number of plumbing fixtures per item II is required and must be shown on the approved Plumbing and Building Plans. Building permits shall not be finalized unless properly sized building sewer is installed. Keep in mind, Certificate of Occupancy is not issued for shell buildings. F. Footnotes In multi-story buildings, Section 413.2.1 of LACPC requires that accessibility (meaning availability) of the required plumbing fixtures not exceed one vertical story. For facilities in mercantile and business occupancies serving customers, Section 413.5.1 of the LACPC allows a single set of restrooms to be accessible (meaning available) to both customers and employees. The required number of fixtures shall be the greater of the required number for employees or the required number for customers. Access to public facilities (for the customer) shall not be through areas designated for employee use only. Accessibility Requirements for Persons with Disabilities: New Facilities: When new facilities are provided, they must comply with disabled access regulations. Existing Facilities: When the existing facility is to be used in determining the overall required plumbing fixtures count (for both proposed addition and existing area), the existing facilities must comply with disabled access regulations (unreasonable hardship may be granted as applicable in Chapters 11A and 11B). Conflicts between Codes: Whenever there is a conflict between Codes or different provisions of the same Code, the most restrictive provision shall be applied.

2902 Article 3 Page 6 of 6 RECOMMENDED BY: ED ALEXANIANS Senior Civil Engineer APPROVED JOHN KELLY Superintendent of Building BY: HASSAN ALAMEDDINE Principal Engineer