Ultra-Low Temperature V.I.P. Series Freezers. Integrated Ultra-Low Temperature Storage Solutions for Biosafety, Security and Performance



Similar documents
IC+ NEW inverter compressor technology delivers energy saving, high performance cooling

Freezers - Ultrafreezers. Platilab & Irilab Series

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

08 FRIDGES & FREEZERS

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

MODEL NU C ULTRALOW TEMPERATURE FREEZERS

Heating oven with mechanical control

Heating oven with mechanical convection

Material test chamber with mechanical convection

Incubator with mechanical convection

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

Digital Ultra-Low Temperature Freezer. Digital Ultra-Low Temperature Freezer, Dual SHFS TM, Chest Type. Dual SHFS TM, Upright Type

Coldrooms designed for your application

Guide to Laboratory Equipment. Panasonic the new name for SANYO.

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

S G G S G G S G G S G G. FR / MF range. Deep Freezers & Plasma Storage Freezers

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

BR I Blood Bank Refrigerators

OT 40L / 90L. Laboratory Steam Sterilizers

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Vacuum drying oven for non-flammable solvents

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Climate chamber with illumination

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Thermo Scientific Forma -86 C Chest and Upright Freezers. Sample Storage Products You Can Trust

CoolTeg Plus Chilled Water (CW) version: AC-TCW

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Bring the fresh in. Dedicated Outside Air Systems

SECTION MORTUARY REFRIGERATORS

BIOMEDICAL REFRIGERATORS

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

LABOKLAV. Autoclaves Made in Germany.

SWIMMING POOL HEAT PUMP Owners Manual

Transport Boxes (active & passive systems)

FVA/A1 saturated-steam sterilizer

S IJDERS SCIE TIFIC B.V.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

ECOCIAT. Domestic hot water heat recovery unit

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

ElastoFlake & ElastoTec

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

LyoBeta. R+D Freeze-Dryers

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Nirvana. Cycling Refrigerated Dryers

HOSHIZAKI AMERICA, INC.

Blood Bank Refrigerators according to DIN Blood Plasma Freezers according to DIN 58375

STERILIZERS, LABORATORY DRYING OVENS

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

MUELLER FALLING FILM CHILLERS

Multi-Range Programmable DC Power Supplies 9115 Series

Screw Compressors ESM Fixed Speed & VS Variable Speed

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

How To Read A Pipe From A Sensor

Controller Setup For Alarm Monitoring: Best Practices. Tim Coyle

FOXAIR 60/50 ALL MODELS

General Purpose Laboratory Freezer with Alarms

North Carolina State University Emergency Facilities Closure Checklist- Part I

Morgue refrigeration unit

VDL 53 - Vacuum drying oven for flammable solvents

MT I Transport Boxes (Active & Passive)

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Tempra / DHC-E. Simply the Best The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control

USER S MANUAL HSC-24A

Laboratory Autoclave SN210/310/510,SQ510/810

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Wireless Data Logger Monitoring Systems

Thermo Scientific Heratherm Microbiological Incubators. Safe,

Refrigeration Compressed Air Dryer Buran Ultrapulse

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Professional Kitchens

WATERBATHS AND OILBATHS

WAECO COOLMATIC 2.8 CUBIC FEET 12/24 VOLTS DC & 110 / 220 VOLTS AC BUILT-IN REFRIGERATOR-FREEZER WITH FLUSH MOUNT FRAME

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Clinic Washer-Disinfectors. Washer-Disinfector Line

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CRAC Precision climate control units for data centres

German engineering under high pressure

Hospital Sterilizers. T-Max Line

ORGANIC SAMPLE PREPARATION

Guide to Laboratory Equipment. My Life. My Work. My Choice.

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Transport and Mailing Systems

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

Our Vector range is growing, so can your profit. Vector Vector 1850

Uninterruptible Power Supply

French Door Refrigerator E23BC78IPS professional series

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

BC Pro UPS System Standby UPS System

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Transcription:

Ultra-Low Temperature V.I.P. Series Freezers Integrated Ultra-Low Temperature Storage Solutions for Biosafety, Security and Performance

The ultra-low temperature freezer VIP series lineup meets diversifying needs for ultra-low temperature storage, including storage of large quantities of biological genetic material, quality control, environmental consciousness, etc. SANYO VIP series ultra-low temperature freezers with patented vacuum insulation cabinet construction, microprocessor controls and high-performance refrigeration achieve the most efficient storage capacity in the industry. Exterior Dimensions Unit: mm (inch) Depth Width Height 76 (3.1 ) 173 (68.1 ) (39.8 ) 68 (27. ) (21.6 ) 94 (37.2 )

The history of SANYO Ultra-Low Temperature Freezers, which constantly push the limits of ever more advanced refrigerating/freezing technology, closely follows the history of biotechnology. History of SANYO Ultra-Low Temperature Freezers Watson & Crick discovered DNA double helix structure Kornburg discovered DNA polymerase Khorana succeeded in synthesis of active DNA C Freezer Cohen & Boyer established gene recombination technology Dangerousness of gene engineering study was discussed in Asilomar conference /8 C Ultra-low temp. freezers Successful human insulin production in E.coli Mullis developed PCR method 13 C Ultra-low temp. freezer 12 C Ultra-low temp. freezer Human Genome Project began 86 C VIP series freezers Human Genome Project completed C VIP PLUS freezer C VIP PLUS freezer MDF-U3V 867 (34.1 ) 186 (73.2 ) 87 (34.4 ) 199 (78.3 ) 87 (34.4 ) (79.1 ) 67 (26.4 ) 77 (3.3 ) (39.8 )

C onstruction Patented VIP insulation technologies SANYO pioneered a revolutionary vacuum insulation cabinet construction that reduces the wall thickness to approximately one half and achieves up to 3% more storage capacity than a conventionally insulated freezer without increasing the footprint. VIP Insulation maximises storage capacity when space is limited. When using multiple units, large amounts Structural Diagram Steel Conventional Insulation Capacity 81L. cu.ft. with V.I.P. Insulation 12% 728L 2.7 cu.ft. 2 box Inventory 4 pcs. 2 boxes 28 pcs. 2 boxes Advanced ultra-low temperature refrigeration system The SANYO cascade refrigeration system is specifically designed for ultra-low temperature applications and offers superior performance and durability, even in high ambient temperatures and in response to frequent door openings. The cooling system maintains uniform temperatures with quiet, energy efficient operation. Accurate microprocessor temperature control The SANYO microprocessor control system utilises SANYO made electronic components to ensure precise and reliable ultra-low temperature operation. R eliability Status alert For improved reliability, Status alert function monitors ambient and system conditions continuously and notifies of any abnormalities before a problem occurs. LCD Status details Countermeasure For upright types Polyurethane foam Barrier film bag Vacuum insulation panel Steel Abnormality in ambient temperature Drop in power supply voltage Overloaded operation Filter-clog check A microprocessor controlled filter check function protects the refrigeration circuit by notifying the user of a blocked condenser filter via an alarm lamp. (Except which is filter-less). Frost reduction SANYO s unique combination of a hot line, routed around the door seal, and insulated inner doors provide an excellent airtight seal which prevents ice build-up around the door. of space can be saved compared to conventionally insulated freezers. Recheck air conditioning of installation location. Use exclusive power supply. Sort contents; inspect door sealing condition. S afety Alarms An alarm lamp and buzzer offer secure warning of power failure or abnormal temperature increase. In addition, battery back-up allows the internal temperature to be checked during a power failure. High and low temperature warnings provide an audible and visual alarm when the temperature deviates more than ± C to ± C (adjustable) from the set point. Alarm ring back function ensures that the buzzer resumes operation, should alarm conditions continue after it is silenced. Remote alarm terminals are also provided as standard equipment for individual or group control. Notifications A battery life notification function is also provided to notify users of accumulated battery time. Self diagnostic The temperature sensor, filter sensor and cascade sensor monitor operation conditions continuously. Should an abnormality be picked up, an error code and the current freezer temperature will be displayed in turn. Tamper proof To prevent unauthorised access to freezer settings, a key-lock function is provided that blocks changes being made through the keypad. Delay start On power failure recovery, typically every unit in the lab will try to start-up simultaneously. This can create a significant drain on the electricity supply and a drop in voltage that may cause the breaker to trip again. SANYO s exclusive compressor start-up delay function enables compressor startup during recovery after a power failure to be delayed for several minutes, in order to reduce and distribute the sudden electrical load during recovery and enable smooth restarting of laboratory operations. Start-up delay is programmable from 2 to 1 min. The advantage of this system is that the start-up of multiple freezers can be staggered over a period of up to 1 minutes, which provides an even electrical load on power failure recovery. C onvenience Data acquisition The SANYO DAQ system, SANYO s original data acquisition software, enables remote setting and monitoring of VIP freezers. (Option) Easy-access filter The condenser filter is situated at the bottom right side of the front panel to make filter removal and cleaning easier. (Except which is filter-less) 1 2 3 2 min. 4 min. 6 min. Start-up sequence Hot line

Upright freezers /U3V/U73V Offers maximum storage volume in the least footprint Provides large capacity in a limited space and helps to meet constantly increasing sample storage needs. Chest freezer for cryogenic preservation Using ultra-low temperature freezer storage for long-term preservation of valuable specimens eliminates worries of contamination, reduces running costs, and enables longterm storage at ultra-low temperatures far below the recrystallization point. Innovative control panel A graphic LCD display panel with pop-up menu function allows simple, intuitive operation and provides detailed information of freezer status. Warning information display Set value MDF-U3V Cabinet Construction Insulated inner doors with gasket offer additional protection during door opening and improve overall energy efficiency in response to ambient temperature change. Easily removable inner doors Inner doors are removable to allow easy cleaning and defrosting. Inner door Easy-to-use tight-sealing door latches The rugged, one-handed operated outer door latch can accommodate a padlock for added protection of valuable samples. A beak style inner door latch tightly closes the inner door against the freezer frame. It also helps make opening and closing the door smoother. Large door latch Current value Message Date/time Door display Status display Full suite of sample protection measures Advanced design, construction and control features provide added safety for valuable specimens. New double type lid gasket ensures an effective seal and suppresses cold air loss. New VIP PLUS insulation material improves the insulation perfor mance of the cabinet. Equipped with new Status alert function. Equipped with LN2 backup system as standard to prepare for any contingency. Data logging function Internal temperature and times when the outer lid has been opened for more than 2 minutes can be recorded for up to 1 month. Logged data can also be easily sent to a PC using the optional communication interface. Inner door latch Control panel The control panel features a clear LED display and a logical keypad layout for easy setting and operation. Chest freezer Perfect size for personal use Space-saving design enables effective use of valuable laboratory space. Simplified high-efficiency refrigerating system Use of a newly developed single-compressor system achieves an approximately % reduction in power consumption. Low-noise design provides quiet, unobtrusive operation ideal for in-lab use. High-density storage 2 box rack IR-A216U(6) + IR-2U(6) Number of 2 boxes 264 3 box rack IR-312UN Number of 3 boxes 144 MDF-U3V IR-2U(8) + IR-224U(8) 32 IR-312U + IR-316U 224 New cooling circuit enables filter-less design Filter-less design makes the routine maintenance procedure of cleaning the condenser filter unnecessary. IR-2U(12) + IR-224U(12) 28 IR-312U + IR-316U 336 IR-2C(14) 1 IR-37C(14) 98 IR-7C(6) 42

Performance Data Temperature ( C) Temperature ( C) Temperature ( C) 1 1 16 2 4 6 8 12 14 16 18 1 1 2 3 4 6 7 8 Temperature ( C) 1 1 16 1 2 3 4 6 7 8 9 11 12 MDF-U3V Temperature ( C) 1 1 16 1 2 3 4 6 7 8 9 11 12 Pull-down characteristics Pull-up characteristics during power failure 1 1 16 1 2 3 4 6 7 8 9 11 12 of 7 C by injection of LCO2 (3kg) 1 2 3 3 All data shown here are measured based on our company standards. If detailed data is required, please contact our company. If product inspection records are required, please contact our company. (There will be a charge for the records.) Please note that the records do not include temperature adjustment range or data on temperature distribution inside the unit. of 13 C by injection of LN2 (kg) 2 1 3 1 of 7 C by injection of LCO2 (3kg) 1 1 2 3 3 of 7 C by injection of LCO2 (3kg) 1 1 2 3 3 of 7 C by injection of LCO2 (3kg) 1 LN2 backup system operation characteristics CO2 backup system operation characteristics 1 2 3 3 Specifications Model Temperature range Maximum cooling performance -12 C to - C (1 C increments) - C (Ambient Temp. 3 C) -6 to -8 C (1 C increments) -8 C (Ambient temp. 3 C) Exterior dimensions (W x D x H) 173 x 76 x mm (68.1 x 3.1 x 39.8 ) x 68 x 94 mm (21.6 x 27. x 37.2 ) Interior dimensions (W x D x H) Net weight Effective capacity Access port 76 x 49 x 61 mm (29.9 x 19. x 24.2 ) Approx. 319 kg (73lbs.) 231 Liters (8.2 cu.ft.) mm diameter, 1 location x 49 x 42 mm (1.9 x 19.3 x 16.7 ) Approx. 67 kg (148lbs.) 84 Liters (3. cu.ft.) 17 mm diameter, 2 locations backside, bottom Compressor Hermetic type, Output: 1W (high stage side), 1W (low stage side) Rotary type, Output: W Refrigerant HFC Alarm system High/Low temperature, Power failure, High/Low temp. alarm (± C to ± C), Filter check, Self diagnosis, Door check, Power failure alarm, Remote alarm contact: Part replacement notification DC3V, 2A Remote alarm contact Accessories Model Temperature range Maximum cooling performance Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Net weight Effective capacity Shelves Access port Compressor Refrigerant Alarm system Remote alarm contact Accessories *Appearance and specifications are subject to change without notice. *Cooling performance is indicated by the temperature reached at the center of the freezer (at ambient temperature of 3 C with no load). In order to use the freezer at a stable temperature for a long time, it is recommended that the temperature be set to at least C higher than the indicated lowest temperature. In addition, depending on the usage conditions, it may not be possible to reach the indicated lowest temperature. Options Model LCO2 backup system LN2 backup system Backup system mounting kit Circular recorder Chart paper Ink pen Slip chart recorder Chart paper Ink pen Recorder mounting bracket Sensor cover Storage racks 3 drawers (for lower chamber) SANYO DAQ (Data Acquisition) system Allowable contact capacity, DC 3V, 2A 1 set of keys, 1 scraper, Connecting tube for 1 set of keys, 1 scraper LN2 backup system 67 x 867 x 186mm (26.4 x 34.1 x 73.2 ) 49 x 6 x 11mm (19.3 x 23.6 x 44.9 ) Approx. 28kg (69 lbs.) 333 Liters (11.8 cu.ft.) Hermetic type, Output: W (high stage side), 6 W (low stage side) Temperature, Power failure, Filter check, Self diagnostics, Remote alarm contact CVK-UB4 MDF-UBK MTR-G8 RP-G8 MTR-8H RP-8 MDF-S38 (for MTR-8H) MTR-C8 MTR- Equipped MTR-1H RP-1 MDF-S3 (for MTR-1H) MTR- MDF-U3V C to 86 C (1 C increments) 86 C (Ambient temp. 3 C) 77 x 87 x 199mm (3.3 x 34.4 x 78.3 ) 63 x 6 x 138mm (24.8 x 23.6 x 4.3 ) Approx. 299kg (69 lbs.) 19 Liters (18.3 cu.ft.) Stainless steel, 3 shelves 17mm diameter, 3 locations (back, bottom left/right corners) HFC CVK-UB2 CVK-UBN2 MTR-G8 RP-G8 MTR-8H RP-8 MDF-S38 (for MTR-8H) MDF-3SC MDF-3R MTR- MDF-U3V CVK-UB2 CVK-UBN2 MTR-G8 RP-G8 MTR-8H RP-8 MDF-S38 (for MTR-8H) MDF-7SC MDF-R MTR- x 87 x mm (39.8 x 34.4 x 79.1 ) 87 x 6 x mm (34.2 x 23.6 x.1 ) Approx. 3kg (772 lbs.) 728 Liters (2.7 cu.ft.) Hermetic type, Output: 1 W (high stage side), 1 W (low stage side) High/low temperature, Power failure, Filter check, Self diagnostics, Door check, Part replacement nortification Allowable contact capacity: DC 3V, 2A 1 set of keys, 1 scraper CVK-UB2 CVK-UBN2 MTR-G8 RP-G8 MTR-8H RP-8 MDF-S38 (for MTR-8H) MDF-7SC MTR- Further details regarding our products can be accessed at http://www.sanyo.co.jp/cmg/biomedical We design and manufacture products in accordance with ISO91 & 1 requirements. RoHS (European Restriction of Hazardous Substances directives) compliant Distributed by: SANYO Electric Co., Ltd. Biomedical Division 8 SANYO Printed in Japan 8.3 MA SHR119