Using Klein Tools Chicago Grips in Common Overhead Applications



Similar documents
KLEIN UTILITY TOOLS & MISC.

Wire Pulling Grips. Wire Pulling Grips

This is an unapproved Kinectrics International Draft Report, subject to change D R A F T DRAFT

Ron Shaham. Expert Witness in Islamic Courts : Medicine and Crafts in the Service of Law. : University of Chicago Press,. p 38

. Perspectives on the Economics of Aging. : University of Chicago Press,. p 3 Copyright University of

May not be reproduced in any form without permission from the publisher, except fair uses permitted under U.S. or applicable copyright law.

71

AERIAL FIBER OPTIC CABLE PLACEMENT

Installation of Corning Cable Systems Self-supporting (Figure-8) Aerial Cable

New range of special alloy conductors Advantages over ACSR & AAAC conductors

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

Series 90 Portable Capstan Hoist. Owners Manual ! CAUTION

Cable Installation Notes

Implosive Connectors. for overhead transmission lines

Cable Preparation and Pulling Procedure Best Practices for Fiber Optic Indoor Tight-Buffered Cable

FALL PROTECTION- Part 2 SELF INSPECTION CHECKLIST

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

Wire Pulling Grips. Wire Pulling Grips. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

TBM5, TBM5-S and TBM5-SV

What is Fall protection?

Load Testing and Lift Engineering

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

SAFE HANDLING OF PRECAST CONCRETE PRODUCTS

Procedure for Cutting and Respooling Fiber Optic Cable

COMPETENCY ANALYSIS PROFILE. Rodworker 452A. (All unshaded skill sets must be demonstrated/ completed) Lift equipment and materials

Transmission Line Loading

Bare Overhead Conductors

Broadband Applications & Construction Manual. Trunk & Distribution Cable Products

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

Sewing Methods Chicago Style Stitch

Working Copy WP 05-WH1401. Revision 4. 6-Ton Electric Forklifts 74-H-010B. Technical Procedure EFFECTIVE DATE: 01/04/06. John Guy APPROVED FOR USE

Case Study Cross Texas Transmission (CTT) & General Cable

Cable-Gard Static Discharge Reels

Effect of Temperature on Wireline Cables Technical Bulletin Ten

WIRE TIES FOR OVERHEAD LIFTING

Safe ladder use. Construction Safety Series. When climbing up or down, workers should:

Operator s Manual. Wahoo Innovations, Inc. Pole Dancer Model Portable Pole Setter. US Patent Numbers: US 61/497,131; US 61/534,930

Optical Cable Pre-Construction Survey. Keywords Stationary Reel Method, empty innerducts, sub-ducts, microducts, Intermediate-feed manholes

Reel Stands and Spindles

STANDARD PRACTICE INSTRUCTION

Horizontal Cable Systems

MESSENGERS FOR AERIAL CABLE

Introduction to Implosive Connectors

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

STREETLIGHT SYSTEM GROUNDING AND BONDING

CONNECTORS Coax & Twisted Pair

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

OVERHEAD CRANE OPERATOR SAFETY TRAINING

Activity 2.3b Engineering Problem Solving Answer Key

GUI Based Optimal Drumming Algorithm for Optical Ground Wire (OPGW) Cables

Wire Rope and Cable Fittings

Voyager Portable. Joerns Healthcare. Redefining patient handling. E a s y t r a c k a n d E a s y t r a c k F S

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

MODEL E-AF. Drain Cleaning Machine. Operator s Manual

Financing New High Voltage Transmission Lines in Nepal Using HTLS Conductors Surendra Rajbhandari, Nepal Electricity Authority Zhang Lei, ADB South

LIFTING WIRE FOR HOT-DIP GALVANIZING BY THOMAS LANGILL, Ph.D.

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

Slings, Rigging and Lifting Equipment

DC RESISTANCE TEST AND WEIGHT MEASUREMENT TEST ON PRAGUE ACCC/TW CONDUCTOR STRANDED BY PT KMI WIRE AND CABLE Tbk COMPANY

The Blocks and Drilling Line

XLPE PRODUCTION PLANT FOR THIRUVALLA UNIT OF TRACO CABLE LTD

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

Installation Guide Hoops (IHS) Cable

Sewer Line Rehabilitation

Cable weight (lb/ft (kg/m)) Minimum Air dielectric. Foam dielectric (0.067) 0.06 (0.09) 0.09(0.13) (0.12) 0.08 (0.12) 0.14 (0.

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

INTERNATIONAL TELECOMMUNICATION UNION #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43

Layout of Hanging Light Strings for Morningside Gym

SAFE USE OF LADDERS AND STEP LADDERS

PORTABLE CAPSTAN AC ELECTRIC PULLING/LIFTING WINCH

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440)

Fall Protection Susan Harwood Grant Training Program 2013 Commercial Roof Fall Safety. OSHA Susan Harwood Training - AGC

Fork Lift Truck Attachments

Hand chain 6,0m 1000kg

For the Hardware Home Center Market Pipe Cleaning Tools since 1930

Belt Drives and Chain Drives. Power Train. Power Train

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

Instruction Manual VB7000. CarbonMax and CarbonPro II Composite Volleyball Systems ( Either in packages or components ordered separately )

Spool Tie. RUS Accepted NOMENCLATURE GENERAL RECOMMENDATIONS (440)

MODEL RF Drain Cleaning Machine

Box and Conduit Fill Calculations

Manufactured by: D & K Engineering Bernardo Center Drive San Diego, CA 92127

Catalog H-115. For the Do It Yourself Market. Made in USA

The Lose-the-Last-1o-Pounds Workout

CCTV System Troubleshooting Guide

Operator s Manual EVENTER 20 / 25 Series Lifts

Belt Conveyor Tracking V-Guide vs. Crowned Roller

DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS

Product classification

Pole Guying More Complicated Than Meets the Eye. NRECA TechAdvantage 2014 Presented by Jason Settle, P.E.

Welding Reel ERA 4000 Service Manual

FALL PROTECTION PROGRAM

When power interruptions happen.

V.A PJM Design and Application of Overhead Transmission Lines 69kV and Above

Cutting and stripping tools

OHIO University Mechanical Engineering Summary Report: Human Power System for Small Appliances and Machinery

Transcription:

Using Klein Tools Chicago Grips in Common Overhead Applications

USING KLEIN TOOLS CHICAGO GRIPS IN COMMON OVERHEAD APPLICATIONS Materials Used: Klein Tools Chicago Grips, Klein Tools KN1500PEX web strap ratcheting hoist, Dillon Dynamometer, chain hoist, leveling block. Disclaimer: This is not intended to be a definitive instructional manual for completing the applications. Always consult company procedures and material guidelines before attempting any application. Dead-Ending a Conductor Cable 1. Set up the ratchet hoist and Chicago grip as shown in the image below. Hoist Dead-End Fixture 2. Ratchet the hoist until the cable is lined up with the dead-end fixture. 3. After the tension is approximately where it will need to be after termination, ratchet the hoist a couple more times, to accommodate for tension loss after hoist removal. Consult cable specifications to ensure the maximum cable tension is not exceeded. 4. When finished, break the tension using the hoist handle, then use either the handle or drum knob to continue releasing the tension. 2

Conductor Cable Sagging Using a Dynamometer 1. Set up ratchet hoist, Chicago Grip and dynamometer as shown in the image below. Hoist Dynamometer 2. Ratchet the hoist until the dynamometer displays the desired tension. Consult conductor specifications or company procedures to determine the appropriate tension. 3. When finished, break the tension using the hoist handle, then use either the handle or drum knob to continue releasing the tension. 3

Splicing Conductor Cables 1. Set up ratchet hoist and Chicago grips as shown in the image below. Hoist 2. Connect the KN1500PEX Web Strap Ratchet Hoist to each grip, and ratchet to the desired tension to make the splice. The cable can now be spliced according to standard work procedures and material guidelines. Hoist 3. When finished with the splice, break the tension using the hoist handle, then use either the handle or drum knob to continue releasing the tension. 4

Using Two Chicago Grips in Tandem For applications where the maximum load exceeds the safe load of an individual grip, or the cable is at risk of deformation, it is recommended to use two Chicago grips in tandem. Using two grips in tandem divides the weight load between both grips, allowing for an effective work load increase of 1.5 times the safe load of each individual grip. For example, if using two Klein Tools 1628-40 Chicago grips, each with a maximum safe load of 25,000 lbs. individually, then the combined working safe load will be 37,500 lbs. In some transmission applications commonly using the 1628-30, 1628-40 or 1628-50 series Chicago grips there is a risk of cable deformation under high tensions. To avoid the risk of cable deformation, Klein Tools recommends the use of two grips in tandem if: 1. ACSR or AAC conductors the load is expected to exceed the lesser of 12,500 lbs. or 40% of the conductor tensile strength 2. ACSS conductors the load is expected to exceed the lesser of 10,000 lbs. or 40% of the conductor tensile strength To use two Chicago grips in tandem, place each grip on the same conductor, approximately five feet apart. Connect a pulley block (leveling block) to the eye of each grip. This will maintain equal distribution of the weight load between both grips. Connect an anchored chain hoist of appropriate capacity to the block as shown in the image below. s Leveling Block Ratchet the chain hoist to the desired tension, as shown in the picture below. s Chain Hoist Leveling Block 5

Additional Best Practices for ACSS Conductors 1. For ACSS conductors larger than 0.953 outside diameter (approximately 600MCM)- use the Klein Tools 1628-50 or 1628-40 series Chicago-style wire-pulling grips. The necessary grip size should be determined based on the cable outside diameter. For applications where the load is expected to exceed 12,500 lbs., use two of the appropriate grips in tandem to prevent cable deformation. For grip recommendations, please contact your Klein Tools sales representative or customer service. 2. For ACSS conductor sizes smaller than 0.953 outside diameter (approximately 600MCM)- use two of the appropriate Klein Tools 1656 series Chicago grips in tandem. The necessary grip size should be determined based on the cable outside diameter. For grip recommendations, please contact your Klein Tools sales representative or customer service. www.kleintools.com 2014 Klein Tools, Inc. Lincolnshire, IL. 60069-1418 Rev. 08/14 A