CYLINDER REFILL AND INSPECTION



Similar documents
INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

STORED PRESSURE STAINLESS STEEL

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

LNG Fuel Tank System LNG Tank overview

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Stainless Steel Single and Dual Circulation Kits

NITROUS TRANSFER PUMP INSTRUCTIONS

2006 HEADSHOK Service Video #1

National- Spencer Inc.

Auto-belay Cable Replacement Process

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

13. REAR WHEEL/BRAKE/SUSPENSION

Cooling system components, removing and installing

81000 Series Aluminum Gate Valve Installation and Repair Manual

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

Self Purging Liquid Trap (SPLT ) User s Manual

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Cylinder HAZMAT & Fill Station Operations Compliance. PSI/PCI, Inc. William L. (Bill) High & Mark A. Gresham

Instructions For SF 6 Refill Kit

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Carpet Washer. vax.co.uk. Rapide Ultra series

Tankless Water Heater

Recharge Procedure for Telemark TVP-2000 and TVP-3500

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Before installation it is important to know what parts you have and what the capabilities of these parts are.

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

PC1131 Electric Air Compressor

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

2012 XX World Cup, XX, & XO Service Manual

Turbocharger system components, servicing

Model 2128 AIR COMPRESSOR PUMP Operating Instructions

PC1130 Electric Air Compressor

SERVICE MANUAL NO for AMEREX HALOTRON I HAND PORTABLE CLEAN AGENT FIRE EXTINGUISHERS (FOR NON-RESIDENTIAL APPLICATIONS)

Meritor WABCO Hydraulic Power Brake (HPB) System Bleeding Procedures

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket

Eliminator Vented Disc Brake Owners Manual

Step-by-step instructions:

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

Code - Code R Service Manual

FLUSHOMETER - TANK SYSTEM

FX TYPHOON 12. Table of Contents

Ozone Generator Manual

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Fuel Injection Pump, Rotary ( )

Installation Instructions and Service Manual

How To Replace A Reverse Osmosis Water Tank

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Trouble Shooting. Pump

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Float and Thermostatic Traps Series H, C and X

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

4-600, 1000 psi. User s Guide to: Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384.


MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

Fire Hydrant Troubleshooting

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

User s Guide CARBON DIOXIDE CYLINDERS AND REGULATORS

DiscPlus DX195 and DX225 Air Disc Brakes

INGROUND, ROPED, AND HOLELESS JACK SEAL REPLACEMENT

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

PARTS NEEDED FOR CONVERTING FROM LP TO NG

2011 Technical Manual

Air Sleeve Maintenance

Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE

To: All Shipowners, Ship Managers, Ship Masters and Classification Societies

ACCUMULATOR INSTALLATION

Play Safe. Safety. Instruction Manual. Rebel Specifications

DST & UST FIRST STAGE REGULATOR

System P/N: G Amerex Workshop Equipment. Amerex Workshop Equipment. Owners & Operators. Owners & Operators Manual. Owners & Operators.

ROUGHNECK II Pumpless Drain

HYDRAULIC TABLE CART 500-LB.

REPAIR AND MAINTENANCE MANUAL

MODEL G300 BRAKE BLEEDER


Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM

DO NOT attempt to repair hub and wheel bearing assembly.

CHROME FRONT BRAKE MASTER CYLINDER KIT

Before repairing your toilet, you must determine

Draining and filling cooling system

SERIES HYDRAULIC MOTOR DRIVEN CENTRIFUGAL PUMPS

STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Assembly and Usage Instructions

Cleaning & Sanitisation

Transcription:

Refill/Inspection Procedure 1 CYLINDER REFILL AND INSPECTION REVISION 2.01 DATE 11.1.2013 1.0 General Information This procedure outlines the process in which Authorized BCA refill centers should complete a refill on an empty Float cylinder. The refill equipment utilized should meet BCA minimum requirements to ensure a quality refill is performed. 2.0 Minimum Requirements 1. The air utilized to fill the cylinder must be SCUBA grade (less than 67ppm of water vapor). 2. The refill equipment must be capable of filling to a pressure of 3000 psi. 3. The refill equipment should include a pressure gauge separate from the gauge on the Float cylinder. The pressure gauge should have an accuracy of at least ±50 psi across the operating range or be Grade 2A or higher. 4. A water bath with a depth that allows ¾ of cylinder body to be submerged should be used during filling. The temperature of the water bath shall be between 50 F 70 F. 5. The fill station shall have a bleed port. The port must allow the pressure to bleed fast enough that the Float cylinder check valve closes and no pressure drop is observed. 6. A clean work place shall be available for resetting and re-greasing the cylinder O-ring. 3.0 Cylinder Inspection 1. Record the following on the refill inspection log 2. Valve head serial number; 3. Cylinder serial number; 4. Manufacturer code; 5. Cylinder type (Pi or DOT); 6. Shop/Technician name and date;

Refill Procedure 2 Figure 1. Location of serial numbers, manufacturer code, and cylinder type. 7. Complete a visual inspection of the cylinder and valve head. If any damage as described below is observed, the cylinder shall not be refilled and the customer instructed to contact BCA. 8. Inspect the Quick Connect Coupler and ensure it has an O-ring and retaining clip installed. See Figure 2. Figure 2: Inspection of quick connect coupling 9. Inspect the trigger pin threads for damage and ensure the pin is not bent. See Figure 3 and 4. Figure 3. Reject for trigger pin thread damage

Refill/Inspection Procedure 3 Figure 4. Reject for bent trigger pin 10. Inspect the cylinder body for damage and dents. See Figure 5 and 6. Figure 5. Reject for damage to cylinder body Figure 6. Reject for dent in cylinder body 4.0 Cylinder Refill WARNING: Before refilling or working on a cylinder, ensure the there is no pressure left in the system, by checking the pressure gauge and deploying the cylinder. NOTE: The refilling equipment utilized should meet BCA minimum requirements. 4.1 Cleaning the Valve to Tank O-ring NOTE: This procedure is only to be performed if the customer has removed valve head from the cylinder. 1. Unscrew the valve head from the cylinder tank.

Refill Procedure 4 2. Remove the valve head to Tank O-ring and use rubbing alcohol and a lint free cloth to clean the O-ring, the valve head and O-ring groove. Allow components to dry. See Figure 7. Figure 7. 3. Inspect and clean the threads on the valve head and cylinder and allow components to dry. 4. Apply fresh vacuum grease to the O-ring and place it in the O-ring groove. 5. Screw the valve head back onto the tank until hand tight. WARNING: Do not utilize tools or excessive force to tighten the valve head onto the cylinder; this may damage the valve head assembly. 4.2 Resetting the Valve Stem O-ring NOTE: The workspace must be clean to prevent contamination of the O-ring. 1. Unscrew the hex screws on the trigger housing. 2. Pull the trigger pin out with your finger and then slowly remove the trigger housing from the valve stem. See Figure 8. Figure 8. Removing the trigger housing 3. Pull the valve stem out of the valve head with your finger.

Refill/Inspection Procedure 5 4. Inspect the Valve stem rubber washer and larger O-ring for damage. See Figure 9 below. Figure 9. Reject for damage to rubber washer 5. Use a dental pick or tooth pick to remove the valve stem O-ring, as shown in the below picture. See Figure 10 below. WARNING: Use care to avoid scratching the valve stem O-ring groove. Figure 10. Resetting the valve stem O-ring 6. Apply vacuum grease to the new valve stem O-ring and install it on the valve stem groove. Place the valve stem back inside the cylinder valve head. NOTE: Ensure the installed valve stem O-ring is free of contamination as this can lead to leakage. 7. Reinstall the trigger housing by pulling out the trigger pin and placing it over the valve stem. 8. Install the hex screws on the trigger housing until hand tight. 4.3 Pressure Gauge Accuracy and Filling 1. Connect fill port on the cylinder to the fill station. 2. Place the cylinder in water and ensure that ¾ of the cylinder body is submerged in water. The valve head shall not be submerged while filling. 3. If a pressure regulator is used, then set the pressure regulator to 2700 psi and fill the cylinder. Allow the cylinder pressure to equalize to 2700psi for 1 minute while filling. 4. After a minute inspect the cylinder pressure gauge and ensure it reads between 2600-2800 psi. If the pressure gauge does not read between 2600-2800 psi, the cylinder shall be discharged and the customer notified to contact BCA. 5. Now bleed the air from the fill station and remove the cylinder.

Refill Procedure 6 6. When bleeding the air from the fill station check the cylinder pressure gauge to ensure the pressure is constant. The cylinders check valve may not close immediately if the system is bled slowly and thus cause a loss in pressure. To avoid this issue bleed the air from the fill station quickly. 7. Allow the cylinder to rest at room temperature for at least 20 minutes. 4.4 Two Week Inspection Period/Shelf Life Test 1. Note the pressure of the cylinder after it has been refilled. 2. Refilling the cylinder will cause it to heat up. After the refill process, it is possible that the pressure can decrease as the cylinder cools to room temperature. It is recommended to wait 20 minutes to see if the pressure drops and then top it off as necessary to reach the desired pressure. 3. We recommend performing a two week shelf life test after filling to ensure that there are no leaks in the system. In the absence of this shelf life test, the customer should always sign the BCA Release of Liability, Waiver of Claims, Assumption of Risks, and Indemnity Agreement. It is recommended that this form be filled out and signed after all refill procedures, whether or not the shelf life test is performed. This form should be filed by the refill center along with completed inspection/refill logs. 4. After 20 minutes at room temperature, record the date, technician s name, cylinder pressure and air temperature at which the measurement is taken on the refill inspection log. 5. To perform the shelf life test, allow the cylinder to sit for 14 days at room temperature. At the end of this time period, record the date, technician s name, pressure and air temperature at which the measurement is taken on the refill template. 6. If the pressure reading at the end of the shelf life test has only dropped by 100 psi from the original measurement and if the pressure falls within the acceptable range (as shown in Table 1 below), the cylinder has passed the shelf-life test. If the cylinder does not meet the above criteria the cylinder failed the shelf life test. Note: If there is a large difference in the temperature when the pressure measurement is taken, there may be a pressure drop greater than 100 psi observed. If this occurs bring the temperature of the cylinder to within 5 F of the previous measurement and re-record the value. If there is still a pressure drop greater than 100 psi observed and outside the acceptable range, the cylinder failed the shelf life test. 7. Record if the cylinder passed or failed the shelf-life test on the refill inspection log. Temperature Range (F) Pressure Range (psi) 50º-58º 2450-2700 59º-67º 2500-2750 68º-76º 2550-2800 77º-85º 2600-2850 86º-94º 2650-2900 95º-103º 2700-2950 104º-112º 2750-3000 Table 1 8. If no shelf life test is performed, then record the pressure on the BCA cylinder pressure adhesive tag and place it prominently on the refilled cylinder. Advise the customer that the pressure gauge must be checked again in 14 days to ensure that it is still within the tolerances above. If the gauge reads less than 2500 psi at room temperature, then the cylinder should be returned to the refill center or BCA for service. Obtain the signed waiver from the customer, check the appropriate boxes on the refill log and keep both documents on file.