Capteur température et humidité pour HVAC



Similar documents
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Electronic Control Devices The European Product Catalogue 2007

S1VF Sonde à visser avec tête de raccordement Threaded probe with terminal head

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Cable Plug acc. to DIN EN , Form A

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Digital display DA 48

Temperature, hygrometry, CO and CO 2. probes for class 310 transmitters

J TB/TW Temperature limiter, temperature monitor

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Silo Temperature probe. Silo thermometry. E 1 SILOTHERMOMETRY REV2B - 14/10/13

Electric Rotary Actuator - On/Off or programmable control actuator

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Model: DC-A2IO Advanced HVAC Controller

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

How To Use A Flowmeter

Digital input modules

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Duct Humidity Transmitter

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Inductive sensor NI10-M18-Y1X-H1141

Electronic Control Devices The European Product Catalogue 2007

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Quick Connect. quick - simple - efficient.

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

E-STOP relays, safety gate monitors

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Contents. Document information

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Linear actuator Econom 0. Our intelligent model: Econom 0. Econom 0

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Digital inductive conductivity transmitter

L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR

Pressure transmitter For general industrial applications Model A-10

Operating Instructions for Plastic Flow Meter. Model: KSK

PNOZsigma - Base units

Plastic tube flowmeters Series PT/PS

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

NUMERIC SIGN SP2-6XX / 180mm. Presentation

DCP Fan Controller. Version 01/2009. The engineer s choice

API Marine. BMS Presentation. Ballast Measurement Systems

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Turbine Flow Sensor Series VTR

Description. Dimensions. Features. precision works better

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

How To Use A Ds340 (Dsp)

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

3DLevelScanner II TECHNICAL DATA SHEET

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

E-STOP relays, safety gate monitors

ALARMLINE ANALOGUE Linear Heat Detection System

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Relative and absolute pressure switch type 529

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

HVAC Sensors Catalogue

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Relative pressure transmitter type 520

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

ACS-30-EU-EMDR-10-MOD

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

NUMERIC SIGN SP2-6XX / 100mm. Presentation

TX OPEN RS232/485 module

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

Instruction Manual. T3111 T3111L T3111P T3111Ex

HERZ-Thermal Actuators

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Heating Controller. Building Technologies HVAC Products

Climate chamber with illumination

Rosemount 333 HART Tri-Loop

Conductive Level Switch FK 2 Technical Data:

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Transcription:

Capteur température et humidité pour HVAC oct-13

Type R 590 Type R 591 Cable Pvc / Pvc Cable Silicone / Silicone Sonde de température Pt100, Pt1000, Ni1000, KTY, NTC, autres sur demande Classe B ou A Raccordement électrique En système 2 fils En système 3 fils Courant de mesure ca. 1 ma Résistance d'isolation à 20 C et 500V DC, typ. 100 MOhm Dimensions 6 x 6 x 29 mm Terminaison des câbles Avec embouts isolés Longueur Câble A définir Câble de liaison 3 x 0,14 mm² PVC / PVC Gamme de T si câble PVC -30...+ 105 C Gamme de T si câble Silicone -50...+ 180 C Classe de protection IP 54 Montage Capot Synthétique Auto Adhésif de 16 x 45 mm Température de stockage -30...+50 C Température d'utilisation -30...+105 C

Type R 598-PVC Type R 598-SIL Cable Pvc / Pvc Cable Silicone / Silicone Sonde de température Pt100, Pt1000, Ni1000, KTY, NTC, autres sur demande Classe B ou A Raccordement électrique En système 2 fils En système 3 fils Courant de mesure ca. 1 ma Résistance d'isolation à 20 C et 500V DC, typ. 100 MOhm Dimensions Bloc Alu de Ø 15 x 20 mm Terminaison des câbles Avec embouts isolés Longueur Câble A définir Câble de liaison 3 x 0,14 mm² PVC / PVC Gamme de T si câble PVC -30...+ 105 C Gamme de T si câble Silicone -50...+ 180 C Classe de protection IP 54 Montage Avec collier inox Température de stockage -30...+50 C Température d'utilisation -30...+105 C

Type R 599-SIL Cable Silicone / Silicone Sonde de température Pt100, Pt1000, Ni1000, KTY, NTC, autres sur demande Classe B ou A Raccordement électrique En système 2 fils En système 3 fils Courant de mesure ca. 1 ma Résistance d'isolation à 20 C et 500V DC, typ. 100 MOhm Dimensions 40 x 25 x 25 mm Terminaison des câbles Avec embouts isolés Longueur Câble A définir Câble de liaison 2 x 0,22 mm² SIL / SIL Gamme de T si câble Silicone -50...+ 180 C Classe de protection IP 65 Montage Magnétique Température de stockage -30...+50 C Température d'utilisation -50...+180 C

Accessoire Longueur nominale M 20 x 1,5 SONDE THERMOMETRIQUE SANS PROTECTION Type R 606

Outdoor Temperature Transformer Supply voltage for 0-10V: 24V AC/DC Analogue output 0-10V: 3-wire connection, min. load resistance 100kOhm Supply voltage for 4...20mA: 10...30V DC, depends on liability (Ubmin = 10V + Rload*0,02A) Analogue output 4...20mA: 2-wire connection, max. Rload(Ohm) = (+Ub-10V)/0,02A Accuracy: ± 0,2K + max. 3% eigenvalue Measurement range: 16 measuring ranges per DIP switch selectable Measurement range options: -50...+50 C, -50...+150 C, -30...+70 C, -20...+50 C, -20...+80 C, 4-20...+120 C, -20...+150 C, 0...+50 C, 0...+100 C, 0...+150 C, 0...+200 C (other on request) Working temperature electronic: -30...+70 C Working range r.h.: 0...98%r.H., without condensation Sensor: Pt100 DIN EN 60751, Class B Electrical connection: screw terminals max. 1,5mm² Cable gland: high-strength cable gland M16 with strain relief Mounting: mounting flange (in scope of delivery) Housing: polyamide (synthetic) Colour: white (like RAL 9010) Protection type: IP65 Dimension: L 64 x W 58 x H 34,5mm Protective sleeve: Ø 6mm VA stainless steel 1.4571 Standards: CE-certificated, EMC according to EN 61326-1 2006, EMV directive 89/336/EWG Storing temperature: -20...+50 C Display: optional LCD-Display, to display the actual-temperature Type R 618 Output T Type R 618.1 4-20 ma R 618.2 0-10 Vdc R 618.3 4-20 ma With Display R 618.4 0-10 Vdc With Display

Outdoor Temperature Transformer Type R 618A.1.Lenght 4-20 ma Supply voltage for 0-10V: 24V AC/DC Analogue output 0-10V: 3-wire connection, min. load resistance 100kOhm R 618A.2.Lenght 0-10 Vdc Supply voltage for 4...20mA: 10...30V DC, depends on liability (Ubmin = 10V + Rload*0,02A) Analogue output 4...20mA: 2-wire connection, max. Rload(Ohm) = (+Ub-10V)/0,02A R 618A.3.Lenght 4-20 ma With Display Accuracy: ± 0,2K + max. 3% eigenvalue Measurement range: 16 measuring ranges per DIP switch selectable R 618A.4.Lenght 0-10 Vdc With Display Measurement range options: -50...+50 C, -50...+150 C, -30...+70 C, -20...+50 C, -20...+80 C, 4-20...+120 C, -20...+150 C, 0...+50 C, 0...+100 C, 0...+150 C, 0...+200 C (other on request) Working temperature electronic: -30...+70 C Working range r.h.: 0...98%r.H., without condensation Sensor: Pt100 DIN EN 60751, Class B Electrical connection: screw terminals max. 1,5mm² Cable gland: high-strength cable gland M16 with strain relief Mounting: mounting flange (in scope of delivery) Housing: polyamide (synthetic) Colour: white (like RAL 9010) Protection type: IP65 Dimension: L 64 x W 58 x H 34,5mm Protective sleeve: Ø 6mm VA stainless steel 1.4571 Standards: CE-certificated, EMC according to EN 61326-1 2006, EMV directive 89/336/EWG Storing temperature: -20...+50 C Display: optional LCD-Display, to display the actual-temperature

Outdoor Humidity-/Temperature Transformer Output r.h. Type H.606.1 4-20 ma Type H.606.2 0-10 Vdc Type H.606.3 4-20 ma With Display Type H.606.4 0-10 Vdc With Display The measurement of the relative humidity and temperature becomes more and more important in the industrial process of measuring and controlling. This device detects the relative humidity and temperature of the environment air by a capacitive sensor, which is protected by a screwable sintered filter (for cleaning). The measured value will be changed into a standardized output signal for further processing. Each device of this series passes through a 2-days test run. Technical Specifications: Relative humidity: Measurement range relative humidity: 0...100% r.h. Measurement inaccuracy relative humidity: < 3% r.h. (in range of 30%...70% r.h. at 20 C, other operating range <5% r.h. at 20 C) Linearity: ± 1% / year 4...20mA (current version, load current <500 Ohm) Temperature dependence at 55% r.h.: < 0,02% r.f. / C (voltage version) Temperature dependence at 55% r.h.: < 0,04% r.f. / C (current version) Temperature: Measurement range temperature: 0 +50 C -20 +80 C -30 +70 C 0 +100 C Measurement inaccuracy temperature: < 0,3K (in range of 10...40 C, other operating range < 0,5K) 4...20mA (current version, load resistance <500 Ohm) Temperature dependence at 20 C: < 0,05 C / 10K (voltage version) Temperature dependence at 20 C: < 0,07 C / 10K (current version) General Data: Supply voltage 4...20mA: 15...36V DC Type H.606.1 Supply voltage 0-10V: 24V AC/DC (± 10%) Type H.606.2 Power consumption: Typ. 10mA (voltage version) Power consumption: Max. 20mA (current version) Electrical connection: Screw terminal, cable diameter max. 1,5mm Housing / colour: Synthetic / white Protection class: IP65 (electronic assembly), version with display IP30 Electromagnetic compatibility: EN 61326-1997 +A1-1998 +A2-2001 (CE) fulfiled low voltage directive according to DIN EN 61010 part 1 Ambient temperature: -20...+ 50 C Operating range relative humidity: 0...99% r.h. Flow rate: < 2m/s Storage temperature: 0...+50 C Sensor protection: Sintered filter Display: LCD-Display Type H.606.3 / 4 Test run: At least 48h test run before delivery

Ø 16 x 190 mm Outdoor Humidity-/Temperature Transformer Output r.h. Type H.606.5.Length 4-20 ma Type H.606.6.Length 0-10 Vdc Type H.606.7.Length 4-20 ma With Display Type H.606.8.Length 0-10 Vdc With Display The measurement of the relative humidity and temperature becomes more and more important in the industrial process of measuring and controlling. This device detects the relative humidity and temperature of the environment air by a capacitive sensor, which is protected by a screwable sintered filter (for cleaning). The measured value will be changed into a standardized output signal for further processing. Each device of this series passes through a 2-days test run. Technical Specifications: Relative humidity: Measurement range relative humidity: 0...100% r.h. Measurement inaccuracy relative humidity: < 3% r.h. (in range of 30%...70% r.h. at 20 C, other operating range <5% r.h. at 20 C) Linearity: ± 1% / year 4...20mA (current version, load current <500 Ohm) Temperature dependence at 55% r.h.: < 0,02% r.f. / C (voltage version) Temperature dependence at 55% r.h.: < 0,04% r.f. / C (current version) Temperature: Measurement range temperature: 0 +50 C -20 +80 C -30 +70 C 0 +100 C Measurement inaccuracy temperature: < 0,3K (in range of 10...40 C, other operating range < 0,5K) 4...20mA (current version, load resistance <500 Ohm) Temperature dependence at 20 C: < 0,05 C / 10K (voltage version) Temperature dependence at 20 C: < 0,07 C / 10K (current version) General Data: Supply voltage 4...20mA: 15...36V DC Type H.606.5 Supply voltage 0-10V: 24V AC/DC (± 10%) Type H.606.6 Power consumption: Typ. 10mA (voltage version) Power consumption: Max. 20mA (current version) Electrical connection: Screw terminal, cable diameter max. 1,5mm Housing / colour: Synthetic / white Protection class: IP65 (electronic assembly), version with display IP30 Electromagnetic compatibility: EN 61326-1997 +A1-1998 +A2-2001 (CE) fulfiled low voltage directive according to DIN EN 61010 part 1 Ambient temperature: -20...+ 50 C Operating range relative humidity: 0...99% r.h. Flow rate: < 2m/s Storage temperature: 0...+50 C Sensor protection: Sintered filter Display: LCD-Display Type H.606.7 / 8 Test run: At least 48h test run before delivery

Outdoor Humidity-/Temperature Transformer Output r.h. Type H.619.1H 4-20 ma Type H.619.2H 0-10 Vdc Type H.619.3H 4-20 ma With Display The shown value in the display is alternating all 5 Sec Type H.619.4H 0-10 Vdc With Display (T value / Humidity value) The measurement of the relative humidity and temperature becomes more and more important in the industrial process of measuring and controlling. This device detects the relative humidity and temperature of the environment air by a capacitive sensor, which is protected by a screwable sintered filter (for cleaning). The measured value will be changed into a standardized output signal for further processing. Each device of this series passes through a 2-days test run. Technical Specifications: Relative humidity: Measurement range relative humidity: 0...100% r.h. Measurement inaccuracy relative humidity: +/- 2% r.h. (in range of 30%...70% r.h, else +/- 3% at 20 C Linearity: ± 1% / year 4...20mA (current version, load current <500 Ohm) Temperature dependence at 55% r.h.: < 0,02% r.f. / C (voltage version) Temperature dependence at 55% r.h.: < 0,04% r.f. / C (current version) Temperature: Measurement range temperature: -30...+70 C / -20 +80 C / 0 +50 C / 0 +100 C Measurement inaccuracy temperature: < 0,3K (in range of 10...40 C, other operating range < 0,5K) 4...20mA (current version, load resistance <500 Ohm) Temperature dependence at 20 C: < 0,05 C / 10K (voltage version) Temperature dependence at 20 C: < 0,07 C / 10K (current version) General Data: Supply voltage 4...20mA: 15...36V DC Type H.619.1H Supply voltage 0-10V: 24V AC/DC (± 10%) Type H.619.2H Power consumption: Typ. 10mA (voltage version) Power consumption: Max. 40mA (current version) Electrical connection: Screw terminal, cable diameter max. 1,5mm Housing / colour: Synthetic / white Protection class: IP65 (electronic assembly), version with display IP30 Electromagnetic compatibility: EN 61326-1997 +A1-1998 +A2-2001 (CE) fulfiled low voltage directive according to DIN EN 61010 part 1 Ambient temperature: -20...+80 C Operating range relative humidity: 0...99% r.h. Flow rate: < 2m/s Storage temperature: 0...+50 C Sensor protection: Sintered filter Display: LCD-Display Type H.619.3H / H.619.4H Test run: At least 48h test run before delivery

Outdoor Humidity-/Temperature Transformer Measurement inaccuracy relative humidity: +/- 2% r.h. (in range of 30%...70% r.h, else +/- 3% at 20 C Type H.619.1H.LENGHT 4-20 ma With Calibration certificate 3 point Humidity and 1 point Temperature Type H.619.2H.LENGHT 0-10 Vdc With Calibration certificate 3 point Humidity and 1 point Temperature Type H.619.3H.LENGHT 4-20 ma With Display With Calibration certificate 3 point Humidity and 1 point Temperature Type H.619.4H.LENGHT 0-10 Vdc With Display With Calibration certificate 3 point Humidity and 1 point Temperature

Outdoor Humidity-/Temperature Transformer Output r.h. Type H.618.1H 4-20 ma Type H.618.2H 0-10 Vdc Type H.618.3H 4-20 ma With Display The shown value in the display is alternating all 5 Sec Type H.618.4H 0-10 Vdc With Display (T value / Humidity value) The measurement of the relative humidity and temperature becomes more and more important in the industrial process of measuring and controlling. This device detects the relative humidity and temperature of the environment air by a capacitive sensor, which is protected by a screwable sintered filter (for cleaning). The measured value will be changed into a standardized output signal for further processing. Each device of this series passes through a 2-days test run. Technical Specifications: Relative humidity: Measurement range relative humidity: 0...100% r.h. Measurement inaccuracy relative humidity: +/- 2% r.h. (in range of 30%...70% r.h, else +/- 3% at 20 C Linearity: ± 1% / year 4...20mA (current version, load current <500 Ohm) Temperature dependence at 55% r.h.: < 0,02% r.f. / C (voltage version) Temperature dependence at 55% r.h.: < 0,04% r.f. / C (current version) Temperature: Measurement range temperature: -30...+70 C / -20 +80 C / 0 +50 C / 0 +100 C Measurement inaccuracy temperature: < 0,3K (in range of 10...40 C, other operating range < 0,5K) 4...20mA (current version, load resistance <500 Ohm) Temperature dependence at 20 C: < 0,05 C / 10K (voltage version) Temperature dependence at 20 C: < 0,07 C / 10K (current version) General Data: Supply voltage 4...20mA: 15...36V DC Type H.618.1H Supply voltage 0-10V: 24V AC/DC (± 10%) Type H.618.2H Power consumption: Typ. 10mA (voltage version) Power consumption: Max. 40mA (current version) Electrical connection: Screw terminal, cable diameter max. 1,5mm Housing / colour: Synthetic / white Protection class: IP65 (electronic assembly), version with display IP30 Electromagnetic compatibility: EN 61326-1997 +A1-1998 +A2-2001 (CE) fulfiled low voltage directive according to DIN EN 61010 part 1 Ambient temperature: -20...+80 C Operating range relative humidity: 0...99% r.h. Flow rate: < 2m/s Storage temperature: 0...+50 C Sensor protection: Sintered filter Display: LCD-Display Type H.618.3H / H.618.4H Test run: At least 48h test run before delivery

Outdoor Humidity-/Temperature Transformer Measurement inaccuracy relative humidity: +/- 2% r.h. (in range of 30%...70% r.h, else +/- 3% at 20 C Type H.618.1H 4-20 ma With Calibration certificate 3 point Humidity and 1 point Temperature Type H.618.2H 0-10 Vdc With Calibration certificate 3 point Humidity and 1 point Temperature Type H.618.3H 4-20 ma With Display With Calibration certificate 3 point Humidity and 1 point Temperature Type H.618.4H 0-10 Vdc With Display With Calibration certificate 3 point Humidity and 1 point Temperature

Outdoor Humidity-/Temperature Transformer Output r.h. Type H.618.1 4-20 ma Type H.618.2 0-10 Vdc Type H.618.3 4-20 ma With Display The shown value in the display is alternating all 5 Sec Type H.618.4 0-10 Vdc With Display (T value / Humidity value) The measurement of the relative humidity and temperature becomes more and more important in the industrial process of measuring and controlling. This device detects the relative humidity and temperature of the environment air by a capacitive sensor, which is protected by a screwable sintered filter (for cleaning). The measured value will be changed into a standardized output signal for further processing. Each device of this series passes through a 2-days test run. Technical Specifications: Relative humidity: Measurement range relative humidity: 0...100% r.h. Measurement inaccuracy relative humidity: < 3% r.h. (in range of 30%...70% r.h. at 20 C, other operating range <5% r.h. at 20 C) Linearity: ± 1% / year 4...20mA (current version, load current <500 Ohm) Temperature dependence at 55% r.h.: < 0,02% r.f. / C (voltage version) Temperature dependence at 55% r.h.: < 0,04% r.f. / C (current version) Temperature: Measurement range temperature: -20 +80 C Measurement inaccuracy temperature: < 0,3K (in range of 10...40 C, other operating range < 0,5K) 4...20mA (current version, load resistance <500 Ohm) Temperature dependence at 20 C: < 0,05 C / 10K (voltage version) Temperature dependence at 20 C: < 0,07 C / 10K (current version) General Data: Supply voltage 4...20mA: 15...36V DC Type H.618.1 Supply voltage 0-10V: 24V AC/DC (± 10%) Type H.618.2 Power consumption: Typ. 10mA (voltage version) Power consumption: Max. 40mA (current version) Electrical connection: Screw terminal, cable diameter max. 1,5mm Housing / colour: Synthetic / white Protection class: IP65 (electronic assembly), version with display IP30 Electromagnetic compatibility: EN 61326-1997 +A1-1998 +A2-2001 (CE) fulfiled low voltage directive according to DIN EN 61010 part 1 Ambient temperature: -20...+80 C Operating range relative humidity: 0...99% r.h. Flow rate: < 2m/s Storage temperature: 0...+50 C Sensor protection: Sintered filter Display: LCD-Display Type H.618.3 Test run: At least 48h test run before delivery