XE-2100 Automated Hematology System. Fast, Accurate, Dependable



Similar documents
Reshaping compact automation. XN-Series Automated Hematology Systems

BC Auto Hematology Analyzer

Pentra DX Nexus. Process efficiency in Hematology

HumaCount System Line A Better Way to Connect. A Better Way to Work.

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

Jennifer G. Collins, RN Children s Hospital of Chicago

Department of Pathology and Laboratory Medicine Capital District Health Authority Nova Scotia

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

NEW YORK STATE CYTOHEMATOLOGY PROFICIENCY TESTING PROGRAM Glass Slide Critique ~ November 2010

Hematology Morphology Critique

Intelligent laboratory management Delivered by cobas IT middleware

QUALITY CONTROL (QC) INFORMATION AND TROUBLESHOOTING GUIDE HEMATOLOGY

R&D Systems Hematology Products

Cytogenetics for the Rest of Us: A Primer

Minneapolis User Group Meeting

CentraLink Data Management System

GE Healthcare CASE. Cardiac Assessment System for Exercise Testing. Connecting hearts and minds.

Pathology No: SHS-CASE No. Date of Procedure: Client Name Address

cobas connection modules (CCM) Sample flow solutions for high-throughput laboratories

Expert workflow management cobas p 312 pre-analytical system The new dimension of laboratory automation

cobas connection modules (CCM) Sample flow solutions for high-throughput laboratories

Yvette Marie Miller, M.D. Executive Medical Officer American Red Cross October 20, th Annual Great Lakes Cancer Nursing Conference Troy, MI

MANUAL WBC LAB OBJECTIVE

Georgia Northwestern Technical College Practical Nursing Program CLINICAL DAILY ASSESSMENT WORKSHEET FOR MODULES I-IV STUDENT: CLINICAL INSTRUCTOR:

Hematology Reagents and Controls Our products for your critical process

Automated and Standardized Counting of CFU Assays for Cord Blood Banks

Cell Viability You Can Count On

Samsung POINT OF CARE Systems - Cardiac/Acute Care Biomarkers LABGEO IB Clinical Chemistry Analytes LABGEO PT

CAP Accreditation Checklists 2015 Edition

Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood

Specific Standards of Accreditation for Residency Programs in Pediatric Hematology/Oncology

GE Healthcare CASE. Cardiac Assessment System for Exercise Testing. Connecting hearts and minds.

COULTER LH 750 HEMATOLOGY ANALYZER. COULTER LH 780 HEMATOLOGY ANALYZER Training Modules. This Training Guide belongs to:

BioVisualization: Enhancing Clinical Data Mining

Medical Laboratory Technology Program. Student Learning Outcomes & Course Descriptions with Learning Objectives

Hepatitis C. Laboratory Tests and Hepatitis C

Automated and Standardized Counting of CFU Assays of Human Hematopoietic Cells

cobas 6500 urine analyzer series Fully automated urine work area on a modular platform

Cytell Cell Imaging System

History of Innovation

Standardization, Calibration and Quality Control

Young fetus: site of hematopoiesis together with the liver and bone marrow. Hgb WBC > < Plt Hct. Retic =

Instructions for Preparing an RFP/RFI Using This Template

Keywords: RBC histogram, Peripheral blood smear, red cell disorders.

Laboratory Studies in the Diagnosis of Iron Deficiency, Latent Iron Deficiency and Iron Deficient Erythropoiesis

Subtypes of AML follow branches of myeloid development, making the FAB classificaoon relaovely simple to understand.

Blood & Marrow Transplant Glossary. Pediatric Blood and Marrow Transplant Program Patient Guide

SWOG ONCOLOGY RESEARCH PROFESSIONAL (ORP) MANUAL VOLUME I RESPONSE ASSESSMENT LEUKEMIA CHAPTER 11A REVISED: OCTOBER 2015

Cord Blood for Cellular Therapy: A Snapshot of this Evolving Market Landscape

Processing & Utilization of Cord Blood for Transplant

Peripheral Blood Stem Cell (PBSC) Collections: Why, What, When. Objectives. Sources of Stem Cells

Captus 3000 Thyroid Uptake And Well System

Connected Vital Signs and ECG Devices Improve Workflow, Patient Care and the Bottom Line at Cardiology of Tulsa

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Going Beyond Laboratory Automation: Do Less Accomplish More. Swedish Covenant Hospital

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Introduction. About 10,500 new cases of acute myelogenous leukemia are diagnosed each

Accelerating EMR Interoperability with ELINCS. Streamlining Lab Connectivity to Physician EMRs

cobas 8100 automated workflow series 3-D intelligence in lab automation

Sutter Health Support Services Shared Laboratory Position Description. Incumbent: Laboratory Date: October 23, 2006 Written By: Michele Leonard

BLOOD COUNT INTERPRETATION. J. Bačovský

Captus 3000 Thyroid Uptake And Well System

Sysmex WAM What s New! Anne Tate Group Manager IT/Automation

Quick Guide SYSMEX XE-5000 TM. Start-Up. QC Analysis. Sample Processing. Sample Explorer/ Data Browser. Body Fluid Mode. HPC Mode. Reagent Replacement

Automated Library Preparation for Next-Generation Sequencing

New QC, parameters, and automation for hematology analyzers

ST. VINCENT'S. MEDICAL CENTER St. Vincent's Healthcare

Stem Cell Transplantation

Bio 20 Chapter 11 Workbook Blood and the Immune System Ms. Nyboer

White Blood Cells (WBCs) or Leukocytes

Interoperability between Anatomic Pathology Laboratory Information Systems and Digital Pathology Systems

flow cytometry reinvented

i-care Integrated Hospital Information System

Thyroid Uptake Systems The Ultimate... User Friendly... Intuitive Captus 3000 Thyroid Uptake And Well System

Emerging New Prognostic Scoring Systems in Myelodysplastic Syndromes 2012

Symmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE

RDW-- Interpreting the Full Blood Count

Our Vision To be the Western Colorado and Eastern Utah laboratory services provider of choice.

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

Practice profitability

ILLINOIS DEPARTMENT OF CENTRAL MANAGEMENT SERVICES CLASS SPECIFICATION CLINICAL LABORATORY TECHNICIAN SERIES

3. The Circulatory System

Laboratory 12 Blood Cells

ABO-Rh Blood Typing Using Neo/BLOOD

On-Time, On-Target Clinical Documentation Meets Today s Demands on Your Terms

Microsoft Amalga Hospital Information System (HIS)

Centricity Perioperative. Surgery and Anesthesia

Enhance Sensitivity of FISH Analysis with Highly Purified Multiple Myeloma Cells Using RoboSep, the Fully Automated Cell Separator

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

Cell Discovery 360: Explore more possibilities.

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

UniCare Professional Reimbursement Policy

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

ViewPoint 6. Clarify your View

Discover Your Potential

Phlebotomy Handbook Blood Collection Essentials Seventh Edition

Laboratory Equipment Training to Improve Quality of Laboratory Services and Patient Care

Transcription:

XE-2100 Automated Hematology System Fast, Accurate, Dependable

Advanced Technology Solutions to Meet your Lab s Needs Even with these challenges, the need for hematology testing has remained steady or continued to grow. Laboratories require hematology analyzers that improve productivity and efficiency while providing enhanced clinical information. Designed to be scalable, reliable and efficient, the Sysmex XE-2100 offers medium to high volume labs an automated hematology system that can truly meet and exceed their expectations. The XE-2100 will streamline your workflow by providing rapid testing for up to 150 samples per hour. Today s Laboratory Challenges Laboratories have continued to face a number of challenges for several years. These include clinical, operational and financial issues. Laboratory requirements include: Clinically relevant information High throughput Hands off automation High reliability Discrete testing options to minimize cost The Sysmex XE-2100 Automated Hematology System utilizes the power of fluorescent flow cytometry and hydrodynamic focusing technologies. Using a unique, state-of-the-art, diode laser bench, Sysmex fluorescent flow cytometry provides the sensitivity needed for measuring and differentiating cell types in both whole blood and body fluid samples. Fluorescent technology and hydrodynamic focusing enable the XE-2100 to consistently classify normal WBC, RBC and PLT populations from abnormal populations, thereby decreasing the number of manual interventions. 1

Clinically Relevant Information Immature Granulocyte Count Unique to Sysmex, the XE-2100 offers a 6-part differential, which includes an Immature Granulocyte Count (IG%, #). The IG count provides reportable, quantitative results that includes metamyelocytes, myelocytes and promyelocytes. Immature Granulocyte Count The IG Count provides: Improved accuracy and sensitivity: Reduced false positive and false negative rates Result consistency by reducing tech-to-tech variation in reporting manual differentials Improved workflow: Fewer manual differentials means faster turnaround time (TAT) Labor Savings: Fewer manual slide reviews improves laboratory efficiency and supports higher laboratory output. Fluorescent Nucleated Red Blood Cells Fluorescent Nucleated Red Blood Cells Enumeration of NRBCs is critical to providing an accurate WBC and differential in pathological samples. The XE-2100 fluorescent technology provides an NRBC in both % and # from a dedicated channel. Standard Parameters: NRBC Fluorescent NRBC count with excellent sensitivity and specificity PLT-O Fluorescent optical platelet count and traditional impedance PLT counting to improve accuracy at low and high PLT counting ranges Retic Fluorescent reticulocyte count to reduce manual confirmation methods and their inherent errors Optional Parameters: RET-He* Reticulocyte Hemoglobin Content measures the incorporation of iron into the red cell to assist the physician in anemia evaluation and management (e.g., functional iron deficiency anemia) The NRBC measurement provides: Improved low-end sensitivity Rapid reporting to assist clinicians in patient diagnosis and treatment decisions Efficient automatic correction of WBC and Diff results Decreased false negative and false positive rates with advanced separation from WBCs and RBCs Available with every CBC or as a reflexive testing option IPF* Immature platelet fraction (measurement of reticulated platelets) to monitor thrombopoietic activity of the marrow HPC* Quantitative hematopoietic progenitor cell count as a screen for the presence of hematopoietic progenitor cells in peripheral blood and cord blood samples * Optional on the XE-2100 2

Advanced Clinical Parameters Fluorescent Reticulocyte Count Fluorescent Optical Platelet Fluorescent Reticulocyte Count Known as the Gold Standard in reticulocyte testing, the fluorescent reticulocyte count is available on the XE-2100. Sysmex provides on-board retic testing in a dedicated channel, improving your efficiency in reporting reticulocytes 24 hours per day. With the use of fluorescent technology, the retic channel provides: Accurate reticulocyte counting in both % and absolute # Improved immature reticulocyte information (IRF) for earlier diagnosis and treatment by clinicians Elimination of common interferences from Howell-Jolly bodies, Pappenheimer bodies and immature reticulocytes to avoid manual counts Reticulocyte Hemoglobin Measurement (RET-He)* RET- He* is a parameter measured in the reticulocyte channel and is used to measure the incorporation of iron into erythrocyte hemoglobin. The RET-He parameter supports: Assessment of anemia and is an established parameter used in KDOQI (Kidney Disease Outcomes Quality Initiative) guidelines for assessing the initial iron status of patients Rapid, direct analysis of an earlier stage of RBC development for prompt clinical follow-up Accuracy and sensitivity in measurement of red cell production that supports effective monitoring of costly drug protocols for cell stimulation Fluorescent Optical Platelet The XE-2100 offers both a traditional impedance count and a fluorescent optical count. The Fluorescent Optical Platelet (PLT-O) is a complementary parameter to the impedance platelet count. The instrument flagging, associated with atypical or abnormal platelets, is minimized by use of the optical platelet count. Use of the optical platelet count on patients with platelet abnormalities, improves the accuracy in reporting results. The PLT-O parameter provides: Improved accuracy on low platelet counts Accurate counts when interferences are present, thus reducing manual intervention Automated judgment for reporting PLT-O or impedance PLT through instrument settings, eliminating tech-to-tech decision variability 3

One Comprehensive System Immature Platelet Fraction Hematopoietic Progenitor Cell Counts Body Fluid Immature Platelet Fraction* Immature Platelet Fraction (IPF %) is a parameter used to assess thrombopoiesis. IPF offers: Accuracy and sensitivity in measurement of immature platelets Delineation of abnormal platelet populations seen by clinicians in disease states such as AITP (autoimmune thrombocytopenic purpura) or TTP (thrombotic thrombocytopenic purpura) Rapid reporting of results for prompt clinical information that can potentially avoid invasive and costly procedures Hematopoietic Progenitor Cell Counts* The Sysmex XE-2100 offers a quantitative hematopoietic progenitor (HPC) cell count that can be used by the physician when determining the optimal time for cell harvest. The Sysmex automated HPC count is substantially equivalent to CFU and CD34+. The HPC count from peripheral blood and cord blood samples supports: Quality screening information to better assist clinicians with patient treatment protocols Rapid analysis versus conventional methods, thereby allowing for a prompt determination of optimal stem cell harvest time Automation of manual processes Cost reduction as the system does not require additional reagents, sample volume or specific technical expertise XE-2100 Body Fluid Analysis: The XE-2100 provides a reportable RBC and WBC count for all common body fluid samples (CSF, synovial and serous). The analyzer applies proven impedance and fluorescent flow cytometry ensuring an accurate body fluid count. The XE-2100 Body Fluid Count Benefits: Improved productivity Decreased turnaround time (TAT) Decreased manual technical intervention No sample pretreatment No additional reagents * Optional on the XE-2100 4

Improved Productivity & Efficiency Maximizing Your Quality and Uptime Productivity The XE-2100 provides a throughput of up to 150 samples per hour, producing high-quality results rapidly for clinicians to use in diagnosis and treatment decisions. The system is compatible with Sysmex automation platforms, providing solutions that can be scalable to meet needs of all laboratories. The XE-2100 can also be used in conjunction with Sysmex WAM Decision Support Software for the Clinical Laboratory, which enhances sample and data workflow and improves turnaround time (TAT). Improved Patient Care An additional benefit to the XE-2100 analyzer is the ability to analyze patient samples when only small volumes of sample are available. The capillary mode (pre-dilute analysis mode) requiring only 40μL of whole blood provides quality clinical data, rapidly and consistently. Your Complete Choice The XE-2100 offers a comprehensive clinical testing menu for both whole blood and body fluids, providing accurate, precise and sensitive results. With its rapid throughput, your physicians receive quality clinically relevant information to assist in management and diagnosis of all patients. Excellent Performance Reliable platform Low sample volume requirements SNCS (Sysmex Network Communications System) remote monitoring system supporting maximum uptime Ranked by independent third party as highest vendor for reliability for 11 consecutive years* *IMV ServiceTrak 2011 Reportable, Diagnostic Information from a Single Sample Analysis 6-part whole blood WBC differential (NE + Lymph + Mono + Eo + Baso + IG) with fluorescent NRBC count Body fluid cell count Anemia evaluation parameters Reticulocyte, IRF, and RET-He* Optical and Impedance Platelet measurement capabilities Thrombopoietic activity assessment parameters (IPF)* Quantitative hematopoietic progenitor cell count (HPC)* *Optional on the XE-2100 Easy-to-use Intuitive software menus On-board help key for rapid troubleshooting Comprehensive quality control information Barcoded reagent management 5

Sysmex XE-2100 Specifications Principles & Technologies Fluorescent Flow Cytometry: WBC-Diff, IG, NRBC, RET, IRF, PLT-O RF-DC method: HPC* DC-Sheath-Flow: PLT, RBC, HCT SLS-Method: Hgb 31 Whole Blood Reportable WBC, RBC, HGB, HCT, MCV, MCH, MCHC, Parameters PLT (Impedance and Fluorescent Optical) NEUT%, LYMPH%, MONO%, EO%, BASO%, NRBC%, NEUT#, LYMPH#, MONO#, EO#, BASO#, NRBC#, IG%, IG#, HPC#*, RDW-SD, RDW-CV, MPV, RET%, RET#, IRF, RET-He*, IPF* Body Fluid Reportable Parameters WBC-BF, RBC-BF Linearity WBC: 0 440.00 x 10 3 /µl RBC: 0 8.00 x 10 6 /µl PLT: 0 5.00 x 10 6 /µl Body Fluid Linearity WBC-BF: >/= 0.050 x 10 3 /µl RBC-BF: >/= 0.01 x 10 6 /µl Throughput Sample Volumes Data Storage (IPU: Information Processing Unit) Quality Control (Total QC Management) Interfaces Whole Blood Mode: 150 samples/hr (max.) 200μL / 130μL (closed/open mode) 40μL for capillary mode 10,000 samples (including graphics) Levey-Jennings control chart X-barM file Comprehensive QC files including current and new lot feature Online Quality Assurance Program - Insight Sysmex WAM TM (HL7 & ASTM) Dimensions / Weight Main unit: 27.8" x 35.9" x 28" / 178 lbs. w x h x d [in] / [lbs] Sampler: 22.8" x 7.7" x 14.8" / 26 lbs. IPU: 18" x 17.6" x 5.3" / 24 lbs. Configurations Standalone Sysmex HST-N, AlphaN Automation *Optional on the XE-2100 6

Sysmex Corporation 1-5-1 Wakinohama-Kaigandori, Chuo-ku, Kobe 651-0073, Japan Tel. +81 (78) 265-0521 Fax +81 (78) 265-0530 www.sysmex.co.jp Sysmex America, Inc. One Nelson C. White Pkwy, Mundelein, IL 60060, U.S.A. Tel. +1 (847) 996-4500 Fax +1 (847) 996-4397 www.sysmex.com/usa Sysmex Canada, Inc. 5045 Oribitor Drive, Building 9, Suite 401 Mississauga, ON, L4W 4Y4, Canada Tel. +1 (905) 366-7900 Fax +1 (905) 366-7899 www.sysmex.ca Sysmex do Brasil Indústria e Comércio Ltda Rua Joaquim Nabuco, 615 - Bairro Cidade Jardim, São José dos Pinhais Paraná Brasil CEP 83040-210 Tel. +55 (41) 2104-1314 Fax +55 (41) 2104-1300 www.sysmex.com.br 2011 Sysmex America, Inc. Document Number MKT-10-1134 06/2011 1M