F A X T H A T P I N O U T 1 5 7 3 2 4 3 1 3 6 5 Fiber Polishing Fiber Testing Hand Soldering Copper Testing 281 LOTUS DRIVE JACKSON, MO 63755 Major Custom Cable YOUR DATA, VOICE, LAN & WAN SOURCE FOR NOW AND THE FUTURE! 1-800-455-6224 MCC # 03/01
Service... 2 YOUR CUSTOM CABLE SPECIALISTS! We pride ourselves on understanding your business as well as our own. You will find our staff understands the value of correct information and critical deadlines. Our systems are set up for automatic blind drop shipping to insure customer confidentiality. Sales Staff... INDEX Jacket Color Code 3 Custom Imprinting & Custom Lengths 3 Media Twist & Lanmark 1000 3 Data Twist 350 & Lanmark 350 4 Category 5 Patch Cords 4 Category 3, 5 & 5E Solid Jumper Cables 5 110 Patch Cords 5 Telco & Power Sum Assemblies 6 T1 Assemblies 7 DS-3/4 Coaxial Cables 7 Ethernet Assemblies 8 Twinaxial & Token Ring Assemblies 9 EMC 300 MHz Data Assemblies 9 Fiber Optics 10, 13 Cisco Router Cable Assemblies 14, 16 SCSI Cable Assemblies 17 V.35 & Null Modem Assemblies 18 DB & RS 232 Assemblies 19 VGA Monitor & SVHS Assemblies 20 Coaxial Cables RG59 21 RGB Coaxial Cables 21 Keyboard & Enhanced Parallel Printer Cables 22 Hydra and Octopus Assemblies 23 Our sales force is on site at our Jackson, Missouri facility. We handle the majority of our business by phone, with periodic personal visits. We feel this method is the most effective way for your people and ours to partner on quotes and bids. The manufacturing information, scheduling and special shipping arrangements can be easily handled to win the various project business for both of our companies. We Have No Order Takers... Our sales staff is trained and updated on the latest product and specification information in this ever changing industry. They are trained to be the liaison between your purchasing personnel and our production staff; helping our customers choose the proper cable for the application. Our engineers are on site to help with requirements or specification issues. RETURNS If one of our assemblies is found to be defective we will be glad to replace it at no charge. We must be notified within 30 days of invoice and before returning any product, a Return Material Authorization (RMA) number must be issued on the merchandise. RMA numbers are valid for 20 days. Please return with the RMA number posted on the outside of each shipping package. Orders for Custom manufactured products are non-cancelable and non-refundable. This includes products with custom lengths, configurations or customer supplied prints or specifications. If you or your customer have a mistake on a custom product, we will be glad to rework the assembly at a nominal charge. PRODUCT WARRANTY A Life-Time workmanship Warranty is provided on all products manufactured by MCC. Warranty is limited to repairing or replacing products which prove to be defective upon inspection. Some products provided by (but not manufactured by) MCC are covered by the warranty of their respective manufacturers. Abuse, alteration, or misuse voids all warranties.
Patch Cord & Jumper Cable Colors Subject to Availability Custom Imprinting! CUSTOM IMPRINTED CABLES WILL ALLOW YOU TO OFFER THE COMBINATION OF HIGH QUALITY AND YOUR PERSONALIZED COMPANY IDENTIFICATION. Custom Lengths! WE WILL CUT YOUR CABLES TO ANY LENGTH WITHIN ENGINEERING SPECIFICATIONS FOR THE TYPE OF CABLE THAT YOU REQUIRE. STOCK COLORS Jacket and Boot Color Code BE - BEIGE (DEC GRAY) BK - BLACK BL - BLUE GY - GRAY (CHROME) GN - GREEN HP - HOT PINK OR - ORANGE PR - PURPLE RD - RED WT - WHITE YL - YELLOW Category 6 Patch Cords (1000 Mbps) UTP Cables Supporting... Meets Proposed Category 6 Specifications 10 Base T, Token Ring, 100 Base T, FDDI/TP - PMD, 155/622 ATM and GigaBit Ethernet Analog Audio, Analog Video, AES/EBU Digital Audio, Digital Video, Serial Digital Video to Mbps (135 Mhz) and Beyond Analog Broadcast to Channel 45 (354 Mhz) and as high as Channel 70 (500 Mhz) Belden Media Twist STRANDED *M64CAPA????? M64CAPA??B??? (E) 568A Special Order Only STOCK COLORS 1. CONNECTORS (RJ45 or BLUNT)? 2. WIRE CODE (568A, 568B,...etc.)? 3. LENGTH (STOCK 3, 5, 7, 14, 20 & 25 FEET)? 4. COLOR? 5. BOOTS? 6. CUSTOM IMPRINTING? NOT STANDARD SHOWN WIRE CODES (E) = RJ45 568A (P) = RJ45 568B (PDS, AT&T, 258A) (V) = 568A or 568B CROSSOVER Cable Manufacturer A = Belden B = Berk-Tek SOLID or Berk-Tek Lanmark 1000 STRANDED M64CBPA????? M64CBPA??B??? * PART # EXAMPLE (M64CAPA??B???) M (Modular) 6 (Category 6) 4 (Pair) C (Stranded) A (Belden) P (568B) A (Mod to Mod)?? (Color) B (Boots)??? (Footage) 1-800-455-6224 FAX: 1-573-243-1365 3
Category 5e Patch Cords (350 Mhz) Belden Data Twist 350 NOT SHOWN The 350 Mhz Enhanced Patch Cords... Provide 350 Mhz performance, exceeding the EIA/TIA 568A Category 5 requirements (100 Mhz) Supports the 155 Mbps transmission rate required for ATM (Asynchronous Transfer Mode). Supports high speed network applications requiring spectral bandwidths that may extend to 350 Mhz. STOCK COLORS Cable Manufacturer A = Belden B = Berk-Tek Berk-Tek Lanmark 350 STRANDED ME4CA?A????? WITH BOOTS ME4CA?A??B??? SOLID or STANDARD WIRE CODES (E) = RJ45 568A (P) = RJ45 568B (PDS, AT&T, 258A) (V) = 568A or 568B CROSSOVER SOLID or STRANDED ME4CB?A????? WITH BOOTS ME4CB?A??B??? Category 5 Patch Cords (100 Mhz) 1. CONNECTORS (RJ45 or BLUNT)? 2. CABLE (STRANDED, SOLID or )? 3. NUMBER OF PAIRS (2 or 4)? 4. WIRE CODE (568A, 568B, etc...)? 5. LENGTH (STOCK 3, 5, 7, 14, 20 & 25 FEET)? 6. COLOR? 7. BOOTS? 8. CUSTOM IMPRINTING? OUR CATEGORY 5 PATCH CORD ASSEMBLIES ARE TESTED AND VERIFIED TO MEET EIA/TIA 568A SPECIFICATIONS. CERTIFIED TO 100 Mhz. STANDARD WIRE CODES (E) = RJ45 568A (P) = RJ45 568B (PDS, AT&T, 258A) (V) = 568A or 568B CROSSOVER 24 AWG. 4 Pair Stranded UTP With Boots *M54CBPA??B??? Without Boots M54CBPA????? Cable Manufacturer B = Berk-Tek STOCK COLORS * PART # EXAMPLE (M54CBPA??B???) M (Modular) 5 (Category 5) 4 (Pair) C (Stranded) B (Berk-Tek) P (568B) A (Mod to Mod)?? (Color) B (Boots)??? (Footage) 4 1-800-455-6224 FAX: 1-573-243-1365 Cable Manufacturer M = Mohawk 24 AWG. 4 Pair Solid UTP M54AMPA??B??? M54AMPA????? M54BMPA??B??? M54BMPA?????
Category 3, 5, 5e Solid Jumper Cables STOCK COLORS STANDARD WIRE CODES (A) = USOC FLIPPED (B) = USOC ST THRU Category 5 2 Pair (RJ11/RJ11) Solid UTP M52A?AA????? M52A?BA????? M52B?AA????? M52B?AB????? CATEGORY 3 SOLID JUMPER CABLES NOT SHOWN QUOTES STANDARD WIRE CODES (F) = DEC FLIPPED (G) = DEC ST THRU (H) = DEC CONVERSION (RJ11/MMP) Category 5 3 Pair (DEC Assemblies) Solid UTP M53A?FA????? M53A?GA????? M53A?HA????? M53B?FA????? M53B?GA????? M53B?HA????? 1. CATEGORY (3, 5 or 5e) 2. CONNECTORS (RJ11, MMP, RJ45 or BLUNT)? 3. CABLE (SOLID or )? 4. NUMBER OF PAIRS (2, 3 or 4)? 5. WIRE CODE (568A, 568B, USOC...etc.)? 6. LENGTH? 7. BOOTS (RJ45 ONLY)? 8. CUSTOM IMPRINTING? Category 5 4 Pair (RJ45/RJ45) Solid UTP M54A?EA????? M54A?PA????? M54A?VA????? M54B?EA????? M54B?PA????? M54B?VA????? STANDARD WIRE CODES (E) = RJ45 568A (P) = RJ45 568B (PDS, AT&T, 258A) (V) = 568A or 568B CROSSOVER Category 5e 4 Pair (RJ45/RJ45) Solid UTP ME4A?EA????? ME4A?PA????? ME4A?VA????? ME4B?EA????? ME4B?PA????? ME4B?VA????? Category 5 110 Patch Cords STOCK COLORS 1. NUMBER of PAIRS on CABLE (1, 2, 3 or 4)? 2. CONNECTORS (110 or RJ45)? 3. NUMBER of PAIRS on 110 CONNECTOR (1, 2, 3 or 4)? 4. WIRE CODE (110 to RJ45) (USOC, 568A, 568B, or 10 BASE T)? 5. COLOR? 6. LENGTH? STANDARD WIRE CODES (B) = USOC (T) = 10 BASE T 2 Pair 110/110 AT52C-??-?? 110/RJ45 ATM52C45B-??-?? ATM52C45T-??-?? STANDARD WIRE CODES (B) = USOC (E) = 568A (P) = 568B 4 Pair 110/110 AT54C-??-?? 110/RJ45 ATM54C45B-??-?? ATM54C45E-??-?? ATM54C45P-??-?? 1-800-455-6224 FAX: 1-573-243-1365 5
Telco 25 Pair Assemblies Category 3 (Male or Female) 24 AWG. UTP T3AMS9SMS9S-??? T3AMS9SFS9S-??? T3AFS9SFS9S-??? T3AMS9SB-??? T3AFS9SB-??? 1. CATEGORY (1, 3, 5 or POWER SUM)? 2. JACKET ( or )? 3. SINGLE or DOUBLE ENDED? 4. GENDER (MALE or FEMALE)? 5. HOOD DEGREE (90, 120 or 180 DEGREE)? 6. 90 and 120 DEGREE HOOD (STANDARD or OPPOSITE EXIT)? 7. LATCH TYPE (SCREW, or BAIL LOCK)? 8. LENGTH? T3BMS9SMS9S-??? T3BMS9SFS9S-??? T3BFS9SFS9S-??? T3BMS9SB-??? T3BFS9SB-??? LUCENT (Part #'s) TPLALM1LM1 180 Degree Hood TPLALM2SLM2S 120 Degree Hood TPLALM9SLM9S 90 Degree Hood TPLALF9SLF9S 90 Degree Hood Female AVAILABLE UPON REQUEST SHIELDED TELCO ASSEMBLIES with 180 SHIELDED HOODS INTEGRAL LATCHES (FEMALE ONLY) PART # EXAMPLE (T3AMS9SFS9S) T (TELCO) 3 (Category 3) A ( Solid) MS9 (First Connector [90 Male]) S {Standard Exit) FS9 (Second Connector [90 Female]) S {Standard Exit) Power Sum 300 MHz Telco Assemblies CUSTOM LENGTHS AVAILABLE CONNECTOR TYPE MS1 = MALE SCREW 180 MS2 = MALE SCREW 120 MS9 = MALE SCREW 90 (STANDARD) MB1 = MALE BAIL LOCK 180 MB2 = MALE BAIL LOCK 120 MB9 = MALE BAIL LOCK 90 FS1 = FEMALE SCREW 180 FS2 = FEMALE SCREW 120 FS9 = FEMALE SCREW 90 (STANDARD) FB1 = FEMALE BAIL LOCK 180 FB2 = FEMALE BAIL LOCK 120 FB9 = FEMALE BAIL LOCK 90 B = BLUNT AMP (Part #'s) TPSAAM1AM1 180 Degree Hood TPSAAM2SAM2S 120 Degree Hood TPSAAM9SAM9S 90 Degree Hood Our assemblies exceed the EIA/TIA SP-2840 Power Sum crosstalk performance for Category 5 applications. Standard RJ21X Lucent offers Power Sum cables with full forward and backward compatibility for seamless Category 3, 4 and 5 connectivity with your equipment. AVAILABLE with JACKET LUCENT JACKET CUSTOM 6 1-800-455-6224 FAX: 1-573-243-1365 This cable is only to be used with AMP Power Sum equipment. The wire configuration is not the same as standard Category 1, 3, 4 or 5 Telco Assemblies! AVAILABLE with or JACKET
T1 Assemblies RJ45 to RJ45 STRANDED T1C4545-??? SOLID T1B4545-??? DB15 to RJ45 (DB15 Male or Female) STRANDED T1C15M45-??? CUSTOM LENGTHS DB15 to DB15 (DB15 Male or Female) STRANDED T1C15M15M-??? T1C15M15F-??? T1C15F15F-??? SOLID T1B15M15M-??? T1B15M15F-??? T1B15F15F-??? STRANDED ASSEMBLIES ARE AVAILABLE IN ONLY 1. CABLE (SOLID or STRANDED)? 2. JACKET ( or )? 3. CONNECTORS (RJ45, DB15 or BLUNT)? 4. GENDER (MALE or FEMALE)? 5. LENGTH? DS-3/4 Coaxial Cables Each DS-3 will carry up to 672 voice channels multiplexed together and each DS-4 will carry up to 4032 voice channels. DS-3/4 cables are used in the telecommunications networks to interconnect Transmission Equipment and Digital Cross Connect (DSX) systems together. DSX to Multiplexer, DSX to Lightwave Systems or Digital Radio to Multiplexer. DS3/4 734A 1 COAX - SOLID COPPER BNC to BNC DS73401ABB-??? SILVER PLATED COPPER AVAILABLE CUSTOM LENGTHS AVAILABLE 1. JACKET ( or )? 2. NUMBER OF COAX (1, 2, 3, 6, 8, 9, 12, etc...)? 3. WITH OR WITHOUT TRACER? 4. CONNECTORS (BNC, WECO, etc...)? 5. LENGTH (FEET or METERS)? DS3/4 735A 1 COAX - SOLID COPPER BNC to BNC DS73501ABB-??? MULTI COAX AVALIABLE 1-800-455-6224 FAX: 1-573-243-1365 7
Ethernet Assemblies 1. ASSEMBLY TYPE (TRUNK, THINNET, AUI or OFFICE AUI)? 2. AUI HOODS (STRAIGHT or CUSTOM 90 RIGHT ANGLE)? 3. CONNECTORS (MALE or FEMALE)? 4. JACKET ( or )? 5. LENGTH? Trunk Cable (Backbone) - (Solid) ETNA-??? ETNB-??? MAXIMUM LENGTH 1,650 FEET (500 METERS) CUSTOM LENGTHS AVAILABLE Thinnet Cable (ThinWire) - (Stranded) ETHC-??? ETHD-??? MAXIMUM LENGTH 607 FEET (200 METERS) MCC's Ethernet Assemblies are fully IEEE 802.3 compliant. BOOTS Available upon Request AUI ASSEMBLIES with 90 HOODS Available upon Request Office Transceiver Cable (AUI Cable) - (Straight Hoods) (Male to Female) - ( only) MII Cable (100 Base T) EMIICMF-??? MAXIMUM LENGTH 19.6 INCHES (.5 METERS) NOT SHOWN Transceiver Cable (AUI Drop Cable) - (Straight Hoods) EAUICM1F1-??? EAUIDM1F1-??? EAUIOM1F1-??? MAXIMUM LENGTH 164 FEET (50 METERS) MAXIMUM LENGTH 16.4 FEET (5 METERS) 8 1-800-455-6224 FAX: 1-573-243-1365
Twinaxial Assemblies Twinaxial to Twinaxial (100 ohm Twinaxial Cable) CTXATT-??? CTXBTT-??? CUSTOM LENGTHS 1. CONNECTORS (DATA, TWINAXIAL,...etc.)? 2. JACKET ( or )? 3. LENGTH? Twinaxial Direct (Data to Twinaxial) - (Type 6) TR6D4T-??? Token Ring Assemblies Token Ring Adapter Cable (DB9 to Shielded RJ45) (Type 6) 10 BASE T TR69FM TR69MM TOKEN RING TR69FMT TR69MMT Patch Cable (Data to Data) - (Type 6) TR6D4D4-??? QUOTES TYPE 9 AND OTHER IBM EQUIVALENT TOKEN RING ASSEMBLIES 1. ASSEMBLY TYPE (PATCH, PC ADAPTER,...etc.)? 2. CONNECTORS (DATA, DB9M or SHIELDED RJ45)? 3. GENDER (MALE or FEMALE)? 4. JACKET ( or )? 5. LENGTH? PC Adapter Cable (DB9 to Data) - (Type 6) TR69MD4-??? TR69FD4-??? AVAILABLE IN ANY COMBINATION OF CONNECTORS SHOWN EMC 300 MHz Data Assemblies The EMC (Electro-Magnetic Control) Data Connector, from AMP,is STP-A performance tested per EIA/TIA 568A specifications. It is bandwidth specified through 300 MHz and is easily identified by its compact design (1/2 inch shorter) and color (Pearl White). The EMC connector interface itself has not been changed making it compatible with ALL other data connectors! 1-800-455-6224 FAX: 1-573-243-1365 9
1. SIMPLEX or DUPLEX 2. MODE (MULTIMODE 62.5/125, 50/125 or 100/140)? 3. CONNECTOR TYPE (SC, FDDI, ST...etc.)? 4. CONNECTORS (Composite Polymer or Ceramic)? 5. JACKET ( or )? 6. LENGTH (ALL LENGTHS IN FEET or METERS)? Fiber Optic Multimode AVAILABLE UPON REQUEST MCC'S MULTIMODE FIBER ASSEMBLIES ARE LOSS GUARANTEED TO (-.5 db) OR LESS PER MATED PAIR. FC, MINI BNC, SC SMA 905, SMA 906, & STAINLESS STEEL ST CONNECTORS 50/125, 100/140 MULTIMODE ASSEMBLIES Please call for any Fiber Assemblies not shown. Corning Cable Systems (Siecor) 662.5/125 Multimode Assemblies ST to ST Simplex ST to ST Duplex SC to SC Simplex SC to SC Duplex FCS6ASTC-??? FCD6ASTC-??? FCS6ASCC-??? FCD6ASCC-??? FCS6BSTC-??? FCD6BSTC-??? FCS6BSCC-??? FCD6BSCC-??? LUCENT 662.5/125 Multimode Assemblies STII+ to STII+ Simplex STII+ to STII+ Duplex SC to SC Simplex SC to SC Duplex FLS6AST-??? FLD6AST-??? FLS6ASC-??? FLD6ASC-??? FLS6BST-??? FLD6BST-??? FLS6BSC-??? FLD6BSC-??? 10 1-800-455-6224 FAX: 1-573-243-1365
Fiber Optic Single-Mode AVAILABLE UPON REQUEST MCC'S SINGLE-MODE FIBER ASSEMBLIES ARE LOSS GUARANTEED TO (-.5 db) OR LESS PER MATED PAIR. SINGLE-MODE SPECIAL POLISHES APC (ANGLE PHYSICAL CONTACT) (-65 db LOSS) (SC and FC CONNECTORS ONLY) SPC (SUPER PHYSICAL CONTACT) (-40 db LOSS) UPC (ULTRA PHYSICAL CONTACT) (-55 db LOSS) 1. SIMPLEX or DUPLEX 2. CONNECTORS (SC, FDDI, ST...etc.)? 3. SINGLE MODE POLISH (STANDARD, APC, UPC or SPC)? 4. JACKET ( or )? 5. LENGTH (ALL LENGTHS IN FEET or METERS)? Corning Cable Systems (Siecor) Single-Mode Assemblies SC to SC Simplex SC to SC Duplex ST to ST Simplex ST to ST Duplex FCSSASC-??? FCDSASC-??? FCSSAST-??? FCDSAST-??? FCSSBSC-??? FCDSBSC-??? FCSSBST-??? FCDSBST-??? LUCENT Single-Mode Assemblies STII+ to STII+ Simplex STII+ to STII+ Duplex SC to SC Simplex SC to SC Duplex FLSSAST-??? FLDSAST-??? FLSSASC-??? FLDSASC-??? FLSSBST-??? FLDSBST-??? FLSSBSC-??? FLDSBSC-??? 1-800-455-6224 FAX: 1-573-243-1365 11
Multi Fiber Assemblies 1. NON-BREAKOUT or BREAKOUT 2. NUMBER OF FIBERS (2 thru 144) 3. MODE (SINGLE-MODE or [MULTIMODE 62.5/125, 50/125 or 100/140])? 4. CONNECTORS (SC, ST...etc.)? 5. JACKET ( or )? 6. LENGTH (FEET or METERS)? 7. FURCATION TUBING (NON-BREAKOUT ONLY)? 8. PULLING EYE FOR EASE OF INSTALLATION? SC, SMA, POLYMER ST, FC, ESCON, & STAINLESS STEEL ST CONNECTORS SINGLE-MODE ASSEMBLIES & 50/125, 100/140 MULTIMODE ASSEMBLIES AVAILABLE UPON REQUEST 62.5/125 Non-Breakout Assemblies NON-BREAKOUT ST to ST () ST to ST (Plenum) # OF FIBERS # OF FIBERS FN602AST-?-??? FN604AST-?-??? FN606AST-?-??? FN608AST-?-??? FN612AST-?-??? 2 4 6 8 12 FN604BST-?-??? FN606BST-?-??? FN608BST-?-??? FN612BST-?-??? 4 6 8 12 ST to ST () FB602AST-?-??? FB604AST-?-??? FB606AST-?-??? FB608AST-?-??? FB610AST-?-??? FB612AST-?-??? FB618AST-?-??? FB624AST-?-??? FB636AST-?-??? # OF FIBERS 2 4 6 8 10 12 18 24 36 62.5/125 Breakout Assemblies BREAKOUT CALL FOR CUSTOM QUOTES ST to ST (Plenum) FB604BST-?-??? FB606BST-?-??? FB608BST-?-??? FB610BST-?-??? FB612BST-?-??? # OF FIBERS 4 6 8 10 12 12 1-800-455-6224 FAX: 1-573-243-1365
High Density Fiber Optic Patch Cords MTRJ Fiber Patch Cords FD6AMTN-??? FD6AMTNSC-??? FD6AMTNST-??? MTRJ using Ribbon Fiber LC Fiber Patch Cords FLD6ALCD-??? FLD6ALCDSC-??? FLD6ALCDST-??? LC Duplex Multimode using 1.6 MM Fiber OPTI-JACK/PLUG Fiber Patch Cords FD6AOJ-??? FD6AOJSC-??? FD6AOJST-??? Standard Patch Cord Fiber MTRJ 1. MODE (MULTIMODE 62.5/125, 50/125, SINGLE MODE)? 2. SECOND CONNECTOR TYPE (SC, ST,...etc.)? 3. SECOND CONNECTORS (Composite Polymer or Ceramic)? 4. JACKET ( or )? 5. LENGTH (ALL LENGTHS IN FEET or METERS)? The MTRJ performs equally well for multimode and single-mode applications. Performance is compliant with ISO/IEC 11801 and EIA/TIA 568A. The MT ferrule is a field proven technology with over a seven year track record and millions of installed parts. LC 1. MODE (MULTIMODE 62.5/125, SINGLE MODE)? 2. SECOND CONNECTOR TYPE (SC, ST,...etc.)? 3. JACKET ( or )? 4. LENGTH (ALL LENGTHS IN FEET or METERS)? The LC Solution is Bellcore, ANSI/EIA/TIA and IEC compliant and SYSTIMAX-SCS approved. For 900 Micron and 1.6 MM fiber both Simplex and Duplex. OPTI-JACK 1. MODE (MULTIMODE 62.5/125, 50/125, SINGLE MODE)? 2. OPTI-JACK or PLUG? 3. SECOND CONNECTOR TYPE (SC, ST,...etc.)? 4. SECOND CONNECTORS (Composite Polymer or Ceramic)? 5. JACKET ( or )? 6. LENGTH (ALL LENGTHS IN FEET or METERS)? The OPTI-JACK is fully compliant with the fiber optic performance requirements as specified in EIA/TIA 568A. 1-800-455-6224 FAX: 1-573-243-1365 13
Cisco Router Cable Assemblies 1. CISCO PART NUMBER? 2. ROUTER MODEL (AGS, 2500,...etc.)? 3. ROUTER TYPE (DCE or DTE)? 4. STANDARD SUPPORTED (V.35, RS232,...etc.)? 5. JACKET ( or )? 6. CONNECTOR TYPE (DB25, V.35,...etc.)? 7. CONNECTOR GENDER (MALE or FEMALE)? 8. LENGTH? This is only a partial listing. Please call for price and availability of unlisted cables. BE SURE OF ROUTER TYPE DCE or DTE RS-232 (HD60 Male to DB25 Male or Female) For Cisco Router Models 7000, 2500 & 4000-NP-4T RS-530 (HD60 Male to DB25 Male or Female) DCE ASSEMBLIES CAB-232MC-??? CAB-232FC-??? DTE ASSEMBLIES CAB-232MT-??? CAB-232FT-??? DTE ASSEMBLIES ONLY CAB-530MT-??? CAB-530FT-??? CAB-232MCP-??? CAB-232FCP-??? CAB-232MTP-??? CAB-232FTP-??? CAB-530MTP-??? CAB-530FTP-??? RS-449 (HD60 Male to DB37 Male or Female) DCE ASSEMBLIES DTE ASSEMBLIES X.21 (HD60 Male to DB15 Male or Female) DCE ASSEMBLIES DTE ASSEMBLIES V.35 (HD60 Male to V.35 Male or Female) DCE ASSEMBLIES DTE ASSEMBLIES CAB-449MC-??? CAB-449FC-??? CAB-449MT-??? CAB-449FT-??? CAB-X21MC-??? CAB-X21FC-??? CAB-X21MT-??? CAB-X21FT-??? CAB-V35MC-??? CAB-V35FC-??? CAB-V35MT-??? CAB-V35FT-??? CAB-449MCP-??? CAB-449FCP-??? CAB-449MTP-??? CAB-449FTP-??? CAB-X21MCP-??? CAB-X21FCP-??? CAB-X21MTP-??? CAB-X21FTP-??? CAB-V35MCP-??? CAB-V35FCP-??? CAB-V35MTP-??? CAB-V35FTP-??? 14 1-800-455-6224 FAX: 1-573-243-1365
Cisco Router Cable Assemblies continued HSSI (High Speed Serial Interface) (MODEL 7000 ONLY) For Cisco Router Model 7000 Only HSSI (MD50 Male to MD50 Male) DTE ASSEMBLIES ONLY CAB-HSI1-??? CAB-HNUL-??? For Cisco Router Models AGS+ & ASM-CS V.35 (HD26 Male to V.35 Male or Female) DTE ASSEMBLIES CAB-VTM-??? CAB-VTF-??? CAB-VTMP-??? CAB-VTFP-??? Maximum Length 20 Feet (6 Meters) Cisco Octal Cable Assemblies 1. FOR AYSNC w/ ADAPTERS (DCE, DTE or MODEM)? 2. CONNECTOR GENDER (DB25 only MALE or FEMALE)? 3. LENGTH? For Cisco Router Models 2509 thru 2512 Jacket ASYNC (HD68 Male to 8 RJ45s) CAB-OCTAL-ASYNC ASYNC w/db25 Adapters (HD68 Male to 8 DB25 Adapters Male or Female) DCE CAB-OCTAL-FDCE or MDCE DTE CAB-OCTAL-FDTE or MDTE MODEM CAB-OCTAL-FMOD or MMOD MODEM (HD68 Male to 8 DB25 Males) CAB-OCTAL-MODEM 1-800-455-6224 FAX: 1-573-243-1365 15
Cisco Router Cable Assemblies continued For Cisco Router 7000 Series STANDARD LENGTH 10 Feet Maximum Length 20 Feet (6 Meters) We make Cisco Router Cable Assemblies for each Series Listed below. Universal Access Server 7000 4000 3800 3600 2600 2500 1600 1500 CS500 Smart Serial Cables for Cisco 2600 Series. For Cisco Catalyst Switches Telco to RJ45 CAB-OCT-232MT (LFH 200M to DB25M) 232 DTE CAB-OCT-V35MT (LFH 200M to V.35M) V.35 DTE CAB-OCT-X21MT (LFH 200M to DB15M) X.21 DTE TPL25ACATALYST (Catalyst 5000) Telco to RJ45 Cable assemblies that far exceed the Category 5 Power-Sum requirements. This assembly is designed to be used with 10 Base-T and 100 Base-T RJ45 Ethernet Switching Modules WS-x5010. WS-x5013.WS-x5224, WS-x5213A,WS-x5223,WS-x5203 and standard 10/100 Base-T patch panel. 16 1-800-455-6224 FAX: 1-573-243-1365
SCSI Cable Assemblies 28 AWG. STRANDED TWISTED PAIR LOW CAPACITANCE DOUBLE SHIELDED FOIL W/BRAID SHIELDED HOODS SCSI 1 (Centronics 50 Male to Centronics 50 Male) SZCC50C50-N-BK SZCC50C50-N-GY SCSI 1 (Centronics 50 Male to DB50 Male) SZCC50D50-N-BK SZCC50D50-N-GY SCSI 2 (Micro D50 Male to Micro D50 Male) SZCM5LM5L-N-BK SZCM5LM5L-N-GY SCSI 1 to SCSI 2 (Centronics 50 Male to Micro D50 Male) SZCC50M5L-N-BK SZCC50M5L-N-GY QUOTES INTERNAL SCSI CABLES ALSO AVAILABLE If you cannot find the cable you require, please call us. 1. CONNECTOR TYPE (CENTRONICS, MICRO D 50,...etc.)? 2. GENDER (MALE or FEMALE)? 3. LATCH TYPE (THUMB SCREW or SPRING LATCH)? 4. JACKET COLOR (BLACK or GRAY) 5. LENGTH? SCSI 2 (DB50 Male to Micro D50 Male) SZCD50M5L-N-BK SZCD50M5L-N-GY SCSI 1 to SCSI 3 (Centronics 50 Male to Micro D68 Male) SZCC50M6S-?-BK SZCC50M6S-?-GY SCSI 3 (Micro D68 Male to Micro D68 Male) Micro D68 Also Available with Latches SZCM6SM6S-N-GY SZCM6SM6S-N-BK Must know if DIFFERENTIAL or SINGLE ENDED Micro D68s with Thumb Screws 1-800-455-6224 FAX: 1-573-243-1365 17
V.35 to V.35 Assemblies 1. CONDUCTORS (19 or 34)? 2. GENDER (MALE or FEMALE)? 3. JACKET ( or )? 4. LENGTH? 19 Conductor Foil Shielded (9 Pair Low Cap) QUOTES 34 Conductor Foil Shielded (18 1/2 Pair Low Cap) V3519CMM-??? V3519CMF-??? V3519CFF-??? V3519DMM-??? V3519DMF-??? V3519DFF-??? V3534CMM-??? V3534CMF-??? V3534CFF-??? V3534DMM-??? V3534DMF-??? V3534DFF-??? Null Modem Assemblies 1. NO HANDSHAKE or FULL HANDSHAKE 2. CONNECTOR (DB9 or DB25)? 2. GENDER (MALE or FEMALE)? 4. HOODS (HIGH IMPACT PLASTIC, METALIZED PLASTIC or METAL)? 5. JACKET ( or )? 6. LENGTH? DB25 to DB25 (No Handshake) (2 Pair) NMCNH25F25F-??? NMCNH25F25M-??? NMCNH25M25M-??? NMDNH25F25F-??? NMDNH25F25M-??? NMDNH25M25M-??? DB25 to DB25 (Full Handshake) (4 Pair) NMCFH25F25F-??? NMCFH25F25M-??? NMCFH25M25M-??? NMDFH25F25F-??? NMDFH25F25M-??? NMDFH25M25M-??? 18 1-800-455-6224 FAX: 1-573-243-1365
"D" Subminiature Assemblies LOW CAP 24 AWG. or FOIL SHIELD FAX THOSE PIN OUTS FOR CUSTOM QUOTES! DB9 1. PIN OUT REQUIRED (ON ASSEMBLIES NOT LISTED) 2. CONNECTORS (DB9, DB15, DB25, DB37 or DB50)? 3. HOODS (HIGH IMPACT PLASTIC, METALIZED PLASTIC or METAL)? 4. GENDER (MALE or FEMALE)? 5. JACKET ( or )? 6. LENGTH? DB9, DB15, DB25, DB37 and DB50 Assemblies Fully Loaded Straight Through DB15 DB25 DB37 DB50 DB9CMM-??? DB9CMF-??? DB9CFF-??? DB15CMM-??? DB15CMF-??? DB15CFF-??? DB25CMM-??? DB25CMF-??? DB25CFF-??? DB37CMM-??? DB37CMF-??? DB37CFF-??? DB50CMM-??? DB50CMF-??? DB50CFF-??? DB9DMM-??? DB9DMF-??? DB9DFF-??? DB15DMM-??? DB15DMF-??? DB15DFF-??? DB25DMM-??? DB25DMF-??? DB25DFF-??? DB37DMM-??? DB37DMF-??? DB37DFF-??? DB50DMM-??? DB50DMF-??? DB50DFF-??? RS 232 Assemblies 1. NUMBER of CONDUCTORS (4, 8, 12, or 25)? 2. GENDER (MALE or FEMALE.)? 3. HOODS (HIGH IMPACT PLASTIC, METALIZED PLASTIC or METAL)? 4. JACKET ( or )? 5. LENGTH? DB25 (4 Conductor) (Wired 1, 2, 3, 7, 20 Shield to 1) DB25 (8 Conductor) (Wired 1-8, 20 Shield to 1) DB25 (12 Conductor) (Wired 1-8, 15, 17, 20, 22 Shield to 1) DB25 Fully Loaded Straight Through RS4CMM-??? RS4CMF-??? RS4CFF-??? RS8CMM-??? RS8CMF-??? RS8CFF-??? RS12CMM-??? RS12CMF-??? RS12CFF-??? DB25CMM-??? DB25CMF-??? DB25CFF-??? RS4DMM-??? RS4DMF-??? RS4DFF-??? RS8DMM-??? RS8DMF-??? RS8DFF-??? RS12DMM-??? RS12DMF-??? RS12DFF-??? DB25DMM-??? DB25DMF-??? DB25DFF-??? 1-800-455-6224 FAX: 1-573-243-1365 19
VGA Monitor Cables 1. MONITOR TYPE (IBM, MACINTOSH,...etc.)? 2. JACKET ( or )? 3. CONNECTOR TYPE (HD15 or DB15)? 4. GENDER (MALE or FEMALE)? 5. LENGTH? MAXIMUM LENGTH (50 FEET) HD15 to HD15 (Standard) VGACH15MM-??? VGACH15MF-??? VGADH15MM-??? VGADH15MF-??? DB15 to DB15 (Macintosh) VGACD15MM-??? VGACD15MF-??? VGADD15MM-??? VGADD15MF-??? SVHS Assemblies 1. CABLE TYPE (ZIP Only)? 2. CONNECTOR ( MINI DIN 4 or BNC)? 3. GENDER (MALE or FEMALE)(NO FEMALE BNC's)? 4. LENGTH? MAXIMUM LENGTH (100 FEET) SVHS (Mini Din 4 to Mini Din 4) ZIP SVZ4MDM4MDM-??? SVZ4MDM4MDF-??? SVZ4MDF4MDF-??? 20 1-800-455-6224 FAX: 1-573-243-1365
RG59 Coaxial Cables BNC to BNC C59ABB-??? WITH BOOTS C59ABBB-??? RG59 75 OHM COAXIAL CABLE 23 AWG. 95% BARE COPPER & AVAILABLE IN ANY COMBINATION OF CONNECTORS SHOWN RCA to RCA C59ARR-??? 1. CONNECTOR TYPE (BNC, F CONNECTOR, RCA or UHF)? 2. JACKET ( or )? 3. BOOTS (BNC ONLY)? 4. LENGTH? F Connector to F Connector C59AFF-??? UHF to UHF C59AUU-??? RGB Coaxial Cables BNC to BNC (3 to 3, 4 to 4 or 5 to 5) RGB3CBB-??? RGB4CBB-??? RGB5CBB-??? SPECIFY LENGTH 5 BNC to HD15 Male RGB5CBH15M-??? 1. NUMBER OF COAX CABLES (3, 4 or 5)? 2. CONNECTOR TYPE (BNC, HD15,...etc.)? 3. GENDER (MALE or FEMALE)? 4. LENGTH? 5 BNC to DB9 Male RGB5CBD9M-??? 4 BNC to DB15 Male (MAC II 13" Monitor) RGB4CBD15M-??? Other Macintosh Cables Available 1-800-455-6224 FAX: 1-573-243-1365 21
1. COMPUTER TYPE (PC/AT, PS/2 or MACINTOSH)? 2. KEYBOARD TYPE (PC/AT or PS/2)? 3. CONNECTOR TYPE (DIN 5, MINI DIN 8...etc.)? 4. GENDER (MALE or FEMALE)? 5. LENGTH? PS/2 (Mini Din 6 to Mini Din 6) DNCM6MM6M-?? DNCM6MM6F-?? DNDM6MM6M-?? DNDM6MM6F-?? Keyboard Cables MAXIMUM LENGTH (50 FEET) PC/AT (Din 5 to Din 5) DNC5M5M-?? DNC5M5F-?? DND5M5M-?? DND5M5F-?? SPECIFY LENGTH PS/2 PC Adapter (Din 5 Male to Mini Din 6 Female) (Din 5 Female to Mini Din 6 Male) DNC5MM6F-?? DNC5FM6M-?? DND5MM6F-?? DND5FM6M-?? Enhanced Parallel Printer Cables (IEEE 1284) 1. CONNECTOR TYPE (DB25, CENTRONICS 36 etc...)? 2. GENDER (MALE or FEMALE)? 3. LENGTH (MAXIMUM LENGTH 33 FEET)? IEEE 1284 Centronics 36/Centronics 36 or Micro Centronics 36 EPCCN36MCN36M EPCCN36MCN36F EPCCN36FMC36M EPCCN36MMC36M Up to 10 times faster than standard parallel printer cables. Use these cables with all IEEE 1284 Bi-directional compliant devices. IEEE 1284 DB25 to Centronics 36 EPCD25MCN36M EPCD25MCN36F EPCD25FCN36M EPCD25FCN36F 22 1-800-455-6224 FAX: 1-573-243-1365
Hydra Assemblies Hydra and Octopus cables are available in many variations. As they are Custom Cable Assemblies, these cables are manufactured to meet your specific requirements. Please call for quotes. 1. CATEGORY (3 or 5)? 2. NUMBER OF CONDUCTORS (2, 4, 6 or 8)? 3. CABLE (SOLID or STRANDED) 4. WIRE CODE (USOC, 568A, 568B...etc.)? 5. CONNECTOR TYPE (RJ45, RJ11 or BLUNT)? 6. TELCO HOOD DEGREE (90,120 or 180 )? 7. 90 and 120 HOOD (STANDARD or OPPOSITE EXIT)? 8. TELCO GENDER (MALE or FEMALE)? 9. JACKET ( or )? 10. NUMBER OF LEGS? 11. LENGTH? 12. SPECIAL INSTRUCTIONS (LABELING,...etc.)? Hydra Assemblies Telco to RJ11, RJ45 or MMP Octopus Assemblies 1. PIN OUT REQUIRED 2. CONNECTOR TYPE (DB25, DB15, DB9, DATA, etc...)? 3. CABLE (STRANDED only) 4. GENDER (MALE or FEMALE)? 5. TELCO HOOD DEGREE (90,120 or 180 )? 6. JACKET ( or )? 7. NUMBER OF LEGS? 8. LENGTH? 9. SPECIAL INSTRUCTIONS (LABELING,...etc.)? PIN OUT REQUIRED FOR THESE ASSEMBLIES 1-800-455-6224 FAX: 1-573-243-1365 23
3M AIM/CAMBRIDGE ALPHA PRODUCTS TYCO/AMP AMPHENOL AUGAT/THOMAS & BETTS BELDEN BERK-TEK C & M CORP. COMMSCOPE COMTRAN CORNING CABLE SYSTEMS/SIECOR COVID FESTO GEI ELECTRONICS GENERAL CABLE HELIX HEWLETT PACKARD OUR FRIENDS IN THE INDUSTRY LUCENT TECHNOLOGIES MADISON MANHATTAN METHODE MOHAWK MOLEX MOYCO NORTHERN TECH NORDX CDT OCC PREH PRESTOLITE SENTINEL STEWART TELEDYNE TROMPETER QUABBIN 24 1-800-455-6224 FAX: 1-573-243-1365