GEO600 Data Acquisition System



Similar documents
Parallels Plesk Automation

Department of Technology Services UNIX SERVICE OFFERING

How To Fix A Powerline From Disaster To Powerline

The safer, easier way to help you pass any IT exams. Exam : Storage Sales V2. Title : Version : Demo 1 / 5

14 Failover and Instant Failover

INFUSION BUSINESS SOFTWARE Installation and Upgrade Guide

Data Acquisition Using NI-DAQmx

Chapter 12 Network Administration and Support

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Small Business Server Part 1

ATTO ThunderLink Thunderbolt to SAS/SATA Troubleshooting Guide

Yiwo Tech Development Co., Ltd. EaseUS Todo Backup. Reliable Backup & Recovery Solution. EaseUS Todo Backup Solution Guide. All Rights Reserved Page 1

LabStats 5 System Requirements

Agenda. Enterprise Application Performance Factors. Current form of Enterprise Applications. Factors to Application Performance.

NetIQ Advanced Authentication Framework. Maintenance Guide. Version 5.1.0

Centralised Backup of the Talis Application Environments

LOCKSS on LINUX. CentOS6 Installation Manual 08/22/2013

- Brazoria County on coast the north west edge gulf, population of 330,242

Very Large Enterprise Network, Deployment, Users

Using. Microsoft Virtual PC. Page 1

Building a Linux Cluster

Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions

Enterprise Edition. Hardware Requirements

Professional and Enterprise Edition. Hardware Requirements

Enterprise Network Deployment, 10,000 25,000 Users

Linux - CentOS 6 Install Guide

Track Forever GPS Tracking Control Center Specification

Acronis Backup & Recovery 10 Workstation. Installation Guide

IGNITE Cloud Server enhancements

The new frontier of the DATA acquisition using 1 and 10 Gb/s Ethernet links. Filippo Costa on behalf of the ALICE DAQ group

This Deployment Guide is intended for administrators in charge of planning, implementing and

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

prerequisites.ppt Page 1 of 14

High Availability and Disaster Recovery for Exchange Servers Through a Mailbox Replication Approach

LAWR BACKUP STRATEGY Second Draft: 5/16/2007

Installation Quick Start SUSE Linux Enterprise Server 11 SP1

SignalPad Data Logging and Analysis Software

High Availability & Disaster Recovery Development Project. Concepts, Design and Implementation

Priority Pro v17: Hardware and Supporting Systems

DeltaV Virtualization High Availability and Disaster Recovery

LOCKSS on LINUX. Installation Manual and the OpenBSD Transition 02/17/2011

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter

Lenovo ThinkServer Solution For Apache Hadoop: Cloudera Installation Guide

ivms-4500(android) Mobile Client Software User Manual (V1.0)

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

actitape LTO-3 and LTO-4 internal SCSI and SAS Quick Start Guide

Positioning with Bluetooth

APPLICATION NOTE GaGe CompuScope based Lightning Monitoring System

Very Large Enterprise Network Deployment, 25,000+ Users

Operating System Installation Guide

SELF HELP PROCEDURE. October, Updated January, 2011

UltraVMTM Dedicated Cloud Servers

PARALLELS SERVER 4 BARE METAL README

ivms-4500(windows Mobile) Mobile Client Software User Manual Version 1.0

Patriot Hardware and Systems Software Requirements

TARRANT COUNTY PURCHASING DEPARTMENT

Acronis Backup & Recovery 11.5

L2F Case Study Overview

The H.E.S.S. Data Acquisition System

CA ARCserve Family r15

Automation Engine 14. Troubleshooting

MedInformatix System Requirements

L.A.M.P.* - Shaman-X High Availability and Disaster Tolerance. Design proposition

COMPELLENT SERVER INSTANT REPLAY: A COMPLETE BOOT FROM SAN SOLUTION WHITE PAPER MARCH 2007

Network Interface Upgrade

Cisco Unified Computing Remote Management Services

How to Install Microsoft Windows Server 2008 R2 in VMware ESXi

XenData Product Brief: SX-550 Series Servers for LTO Archives

TheraDoc v4.6.1 Hardware and Software Requirements

SecureVault Online Backup Solution OGCIO. 26-June-2012 Marketed by:

Upgrading Small Business Client and Server Infrastructure E-LEET Solutions. E-LEET Solutions is an information technology consulting firm

Fanuc 0 M/T Model C Serial (RS232) Connection Guide

System requirements for MuseumPlus and emuseumplus

Maximum vsphere. Tips, How-Tos,and Best Practices for. Working with VMware vsphere 4. Eric Siebert. Simon Seagrave. Tokyo.

DAC Digital To Analog Converter

Configuration Maximums VMware vsphere 4.0

ABB Technology Days Fall 2013 System 800xA Server and Client Virtualization. ABB Inc 3BSE en. October 29, 2013 Slide 1

HDMI over IP Broadcasting System ITEM NO.: HE05BT, HE05BER HDMI Matrix over IP Broadcasting

Acronis Backup & Recovery 10 Server for Windows. Installation Guide

BackupAssist v6 quickstart guide

Data Information and Management System (DIMS) The New DIMS Hardware

Acronis Backup & Recovery 11

Intelligent disaster recovery. Dell DL backup to Disk Appliance powered by Symantec

Virtuoso and Database Scalability

NEWSTAR ENTERPRISE and NEWSTAR Sales System Requirements

DCS Data and communication server

Migrating to ESXi: How To

Keys to optimizing your backup environment: Legato NetWorker

Simple Software for a Business Continuity Plan and a Disaster Recovery Plan (BCP DRP) pdf ppt

Serial ATA 2 Ports PCI Host

RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES

Cisco Smart+Connected Remote Management Solution for Real Estate Developers

A remote diagnostics system for the MERLIN array. D. Kettle, N.Roddis Jodrell Bank Observatory University of Manchester Macclesfield SK11 9DL

Mediatrix Gateways and ISDN Clock Synchronization June 22, 2011

How To Run An Ultravm Cloud Server

STORAGETEK 2540 ARRAY

HP StorageWorks Entry-level Enterprise Backup Solution

For version p (September 4, 2012)

Red Hat Enterprise linux 5 Continuous Availability

EBERSPÄCHER ELECTRONICS automotive bus systems. solutions for network analysis

Transcription:

MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK ALBERT-EINSTEIN-INSTITUT GEO600 Data Acquisition System DC Workshop, Golm 2002-02-20 Karsten Kötter, Martin Hewitson 2002-02-20 Karsten Kötter 1

frames187gb(~3 SUNwoRAID days) op rkstation HanRuthe DCU over DCUDCU 35+2 MbRadioLink rawdata187gb(~3 days) frames436gb(~8 days) tape 7-slotdrive(transfer togolm) tape1-slotdrive S RAID S SRAID dah-cun erver UN erver Myframe make SQL-databaseserver hourtrendfiles daytrendfiles maker make frame reducedataset (for Ruthe) server eratingthetapedrive generation hanel tacollector taserver Beowolf switc switc cluster hlinuxhtp-server databasefron SUN DataViewer inglasgo hworkstation?(tasksfromtheserversmightdistributedto DCrobot Machine machine) t ty w t MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT-EINSTEIN-INSTITUT DAQS Schematic SUN workstation frameserver (for Hannover) Beowolf cluster frames 187GB (~3 days) RAID tape 7-slot drive (transfer to Golm) SUN workstation operating the tape drive switch DC robot Linux HTTP-server Hannover Ruthe rawdata 187GB (~3 days) frames 436GB (~8 days) DCU DCU DCU RAID RAID tape 1-slot drive SUN Server SUN Server datacollector dataserver h-channel generation MySQL- database server framemaker make hour trend files make day trend files make reduced data set frameserver (for Ruthe) 35+2 Mb RadioLink switch database frontend DataViewer SUN workstation Machine is currently in Glasgow??? (tasks from the SUN servers might be distributed to this machine) 2002-01-16 2002-02-20 Karsten Kötter 2

Advancements since 2001-06 Hardware works OK now in desired operating mode "channel swapping" problem solved LIGO timing hardware replaced by timing card built in Glasgow channel swapping not observed ever since hardware replacement 2002-02-20 Karsten Kötter 3

System robustness system automatically recovers from timing signal transmission failures automatic FIFO flush crash of datacollector software "forking" ensures parent process stays alive reboot of DCUs automated reconnect after boot up 2002-02-20 Karsten Kötter 4

Hardware acquisition possible with up to 16384Hz sampling rate 24bit resolution (limited to ~16bit by noise) 2002-02-20 Karsten Kötter 5

Relative timing accuracy 2002-02-20 Karsten Kötter 6

max. resolution (1) 2002-02-20 Karsten Kötter 7

max. resolution (2) 2002-02-20 Karsten Kötter 8

Hardware "to-do" list order spare parts slow channels testing timing accuracy against independent clock data integrity dependence of effective resolution of AD-conversion on pre-amplifier gain dominating noise source is pre-amp noise floor is different for different amplification/attenuation factors 2002-02-20 Karsten Kötter 9

Software (1) ALL software rewritten since 2001-05 easier to configure all configuration information is stored in database now configuration changes done by Web-Interface LabView control data included in frames ~1000 channels at 1 Hz SR trend data generated "hour trends" SR=1Hz "day trends" SR=1/60Hz upgrades in frame-/dataserver functionality control data trend data frequency domain data 2002-02-20 Karsten Kötter 10

Software (2) new tools to look at GEO data DataViewer Web Tool to look at data in both time and frequency domain LabView oscilloscope Oscilloscope / FFT-Analyser functionality Real time data monitoring in both time and frequency domain 2002-02-20 Karsten Kötter 11

Raw data collection datacollector is running for several month now without any problems database moved to DAQ server "morgan" for more reliability 2002-02-20 Karsten Kötter 12

frame builder is running for several month now without major problems "hangs" from time to time might be problem due to nfs-mount over radio link new sever running framemaker will be located in Ruthe to remedy problem 2002-02-20 Karsten Kötter 13

Data access frameserver in Ruthe last 8 days of data available (436 GB capacity)?? days of hour trend data 110MByte/day?? days of day trend data 2MByte/day 2002-02-20 Karsten Kötter 14

Data transfer 1-slot tape drive available in Ruthe fallback solution only in case radiolink goes down 7-slot-tape drive available in Hannover will be used for continuous tape writing (transfer Golm/Cardiff) 2002-02-20 Karsten Kötter 15