TecCrete. Data Center Flooring



Similar documents
Power. When and where you need it.

Understanding Raised Floor Systems for the Specifier (2008)

Iso Floor Raised Floor System

Data Center The New Standard in Data Center Design... ASM H-D System

A few inches will give your business room to grow...

Modular Access Floor for Data Center. From Rack to Row to Room to Building

MERO Access Floor / Floor systems for data centers * *Ready for Cloud-Computing

In-Floor Cooling Solutions. In-Floor Cooling Solutions. Airfl ow Management Solutions for Raised Floor Data Centers

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

GENERAL PROVISIONS

Element D Services Heating, Ventilating, and Air Conditioning

Thermal Optimisation in the Data Centre

How to Meet 24 by Forever Cooling Demands of your Data Center

Airflow Utilization Efficiency (AUE) Can we cool today s servers with airflow?

GUIDELINE SPECIFICATIONS

Iso Floor. the only dynamic raised floor on the market

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Standing Seam Roof Systems

Rack Hygiene. Data Center White Paper. Executive Summary

Product description NCC Data Center

Springlok Flashing System

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

metal Duil~ing manufacturers Association

PC-Concrete Injectable Concrete Anchoring and Repair System

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

BURNISHED SLATE COVER PHOTO: SLATE GREY

- White Paper - Data Centre Cooling. Best Practice

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

James M. Pleasants Company

Data Centre and Server Room Technical Cleaning

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Secondary Containment Comparison ATI Ultra COAT vs HDPE

Customized Server Cabinets

Managing Data Centre Heat Issues

ROOFS - Guidance for Repair, Maintenance and Replacement

LOOK. For more information call or Download additional copies at haworth.com.

Window Installation Instructions

Haworth s Product to LEED Points. LEED - Commercial Interiors

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Building Owners Guide to a Duro-Last System!

The space-saving storage solution.

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

COMMERCIAL BUILDING APPLICATIONS

CHAPTER 7: Building Systems ROOFING SYSTEMS

VERTICAL DESIGN OPTImAL ACOUSTICS

YOUR HOME DESERVES AN ENGLERT METAL ROOF

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Commercial Portable Air Conditioners

WHITE PAPER. Creating the Green Data Center. Simple Measures to Reduce Energy Consumption

SECTION STORAGE SHELVING. Copyright ARCAT, Inc. - All rights reserved

WHAT IS PCL3 DIGITAL?

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

techorganizer and techbench built for durability, designed for flexibility

Profiles. Exclusively Manufactured By

Tate s Wire & Cable Solution

stand the tests of time, & economics

MIDMARK DENTAL CABINETRY vs LOCAL CABINET MAKERS

DENVER MODEL 30 X 30 SPECIFICATIONS

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Access Floor Solutions

8.7 Schluter -KERDI-LINE

Reflective Safety Products. Home Automotive Commercial

Select Radiators Installation Guide

Adding value to the finest homes in Virginia for 52 years! years

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Cabinets 101: Configuring A Network Or Server Cabinet

Colorado State University. Durrell Center Roof Repair

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Division 9. SignaFlor Pad and Pour Flooring System

SECTION WARDROBE AND CLOSET SPECIALTIES PART 1 - GENERAL

The Peak of Protection

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Specialty Environment Design Mission Critical Facilities

"PARTNERS IN PACKAGING

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Data Center Components Overview

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Rooflight INSTALLATION INSTRUCTIONS

CLEAR-DIVISIONS APERTO

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

COLORADO MODEL. 35 x 65 SPECIFICATIONS

How To Compare Roofing Material

SECTION PLAYGROUND SURFACING TILES

The Future is Raised Access Floors

Composite Panel Firewall Systems

Transcription:

TecCrete Data Center Flooring

The TecCrete Data Center product is based on Haworth s proven TecCrete access flooring platform. For the last 30 years, it has been the leading choice for architects and developers who prefer a top-quality access flooring system with best-in-class features. Haworth, a family owned manufacturer based in Michigan since 1948, is committed to making TecCrete products in the USA. TecCr et e Data Center Haworth has built on TecCrete s legendary performance and durability by adding technology-friendly surface finishes and high-efficiency airflow panels to create the TecCrete Data Center, an advanced system of access flooring products engineered specifically for critical computing and telecommunications environments. BEST WARRANTY IN INDUSTRY > 5 Year Structure > 3 Year HPL Delamination The Greenest Access Floor in the Industry 58% recycled content (contributes to LEED MR 4.1 & 4.2). Certified by Greenguard Children and Schools as a lowemitting product (contributes to LEED IEQ 3.1). Manufactured in our Kentwood, MI plant, a Zero Waste to Landfill facility. 3

T eccr e t e PERFORMANCE Product Static Loading Rating Dynamic Load Rating System Panel Understructure Concentrated Uniform Ultimate Rolling 10-Pass Rolling 10,000-Pass 1250 1 1/8 Panel Cornerlock 1250 lbs 600 lbs 1800 lbs 1200 lbs 800 lbs 1500 1 1/8 Panel Stringer 1500 lbs 700 lbs 2500 lbs 1500 lbs 1250 lbs 2000 1 1/2 Panel Stringer 2000 lbs 800 lbs 2800 lbs 1500 lbs 1250 lbs 2500 1 1/2 Panel HD Stringer 2500 lbs 900 lbs 3100 lbs 2000 lbs 2000 lbs Standard Duty panel for everyday applications. 1.125 Heavy Duty panel for heavier load requirements. 1.5 Pedestals for stan dard an d seismic applications Type 0 Type 1 Type 2 Type 3 Type 4 Type 5 4 5

Engineered for reliability, safety, an d installation ease N o Zi n c w h is k ers Proprietary Concrete and Steel Composite Design Solid rolling load support. Steel shear tabs cause the concrete and steel to behave as a single composite material, combining compressive strength and tensile strength for unmatched static and dynamic load performance. Industry s only weldless steel pan ensures structural integrity throughout product lifecycle. Full Panel Thickness Superior load-bearing support. Solid 1 1/8 or 1 1/2 thick throughout entire panel. Full panel thickness rests on understructure, eliminating structural vulnerability at panel edge and corner. TecCrete Data Center uses electronic grade metal finishes to ensure that no zinc whiskers develop. Reduced Airborne Contaminants Structural concrete won t flake during installation. Limit dust in day-to-day operations. Ground Path Positioning Tab Built-in positioning tabs on every stringer eliminates racking or skewing of panel grid. Flat Underside Allows easy mounting of server racks or other equipment to the access floor. Easily add support pedestals at any location. Flexible understructure placement aids installation of cut panels at walls and columns. Multi-point grounding for dependable static protection and electrical safety. Server Rack Two points of metal-to-metal contact at each corner offer eight points of ground path redundancy on every panel. Flat Underside Allows for mounting screws to be located anywhere on panel without using struts on bottom. 6 7

AIrflow panel options for all applications 25% open area perforated panels Delivers 19% more air volume than competitive equivalent. Integrated steel grid withstands heavy rolling loads. 1000 lbs rolling load per CISCA Section 3. 55% open area aluminum grates Light, strong cast-aluminum construction. Enhanced airflow and cooling. 8 9

Th e Haworth T eccr e t e data center cooling advantage T eccr e t e Integral Air Seals 56% open area Triad Chamfer Airflow panel features patented airflow enhancement technology. Only TecCrete Data Center panels have the option of an integral air seal attached directly to the panel side. Steel design offers heavy-duty load capacity. Multi-directional fins under panel increases airflow over flat-bottom grates. Higher cooling plume allows cold air to reach entire height of rack. 56% open Triad Chamfer Airflow panel. Upper server temperatures can be reduced 10 20 degrees Fahrenheit. Highly durable silicon foam seal. Overall cooling requirements may be reduced by as much as 40%. Airflow fins Optional air seals provide compression fit that reduces cooling loss through panel seams by as much as 90% over conventional unsealed data centers floors. Provides improved air-containment within data center plenum, creating improved airflow to grates or perforated panels at server racks. Standard Panels/Grates Triad Chamfer ICE Cold Aisle Containment Air Leakage: Conventional Floor vs. TecCrete with Air Seal Hot air recirculation to cold aisle Stratification Level Improved Hot Aisle Containment flow Stratification Level Air Leakage (CFM/ft 2 ) 0.25 0.2 0.15 0.1 0.05 0 Air Leakage Rates 0.05 0.1 0.2 0.3 0.4 TecCrete with Airseal Steel Panel Air-Flow Panel Air-Flow Panel Static Pressure In. of H 2 0 Most standard grates only provide enough air volume to reach the lower half of the server rack. The multi-directional fins on Triad air flow panels increase the volume of air flowing against all server surfaces, from bottom to top. Combine TecCrete Air Seals with the Triad Chamfer Airflow panel for the most efficient data center cooling system. 10 11

Bare Surface crete Finish Systems engineered for the Long Run data center and Supported by the Industry s Longest Standard Warranty Against Delamination T eccr e t e Data Center TecCrete Bare the latest in finishing technology Only TecCrete access floor can be used bare with field applied Electraseal ESD or Electra-guard conductive coatings. Durable bare finish eliminates the hassle and expense resulting from cracking, chipping or delamination of high pressure laminate. Bare tiles can be secured using cornerlock screws to eliminate the use of stringers, saving both time and expense. Coating on the Bare surface becomes an integral part of the panel, yielding superior function and increased life expectancy as compared to factory finished high-pressure laminate panels. Only TecCrete Data Center products offer a three-year warranty against delamination of HPL or vinyl. Haworth has applied its sixty year experience in surface finish adhesion to engineer a finish, adhesive, and substrate system that works flawlessly, even under adverse conditions. Data Center standard finishes include: 1/6 or 1/8 anti-static high-pressure laminate with TecTrim edge 1/16 or 1/8 conductive laminate with TecTrim Edge Conductive Vinyl with Captured Trim Edge Performance Durability Aesthetic Affordability 12 13

product summary Solid panel system options: TecCrete 1250 without stringer TecCrete 1500 with stringer TecCrete 1500sl without stringer TecCrete 2000 with stringer TecCrete 2500 with stringer Solid panel finish options: Field-applied acrylic surface finish Field-applied Electraseal ESD finish Field-applied Electraguard conductive finish Factory-applied 1/16 or 1/8 anti-static or conductive high-pressure laminate with TecTrim edge Factory-applied conductive vinyl with captured trim 25% airflow panel finish options: Factory applied 1/16 or 1/8 antistatic or conductive high-pressure laminate with TecTrim edge Factory applied conductive vinyl with captured trim 55% grate finish options: Powder-coat epoxy finish 56% Triad grate finish and fin options: Available with or without field-installable fin sets Finished in conductive powder-coat epoxy Understructure options: Seismic rated pedestals Floor heights from 3 to 48 FFH, additional heights available upon request

For more information call 800.344.2600 or 616.393.3000. Download additional copies at haworth.com This brochure is printed on FSC certified U2 :XG paper, manufactured with electricity in the form of renewable energy (wind, hydro, biogas) and contains a minimum of 30% post-consumer recovered fiber. FSC is a global benchmark for responsible forest management. Haworth is a registered trademark of Haworth, Inc. Printed in USA Haworth, Inc 2011 12.11 Item #0383 Haworth.com Haworth-Europe.com Haworth-Asia.com