McSmart 160C. McSmart 160C INDICE / INDEX SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM



Similar documents
Condensing unit type EPSILON-ECHOS LE Technical information manual

ECP 208. Cold Rooms Controllers USER S MANUAL

Comando elettrico di potenza ( motori e resistenze ) Electrical power parts ( motors and heaters )

INDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS. Criteri di scelta pag Product selection. Caratteristiche tecniche pag Tecnical data

BURNER WATER CONTROL UNIT

Start Up Delay PC Board P/N CM By-pass Switch P/N CM Metal bracket Warning Label

MACCHINA DA CAFFE' AUTOMATICA AUTOMATIC COFFEE MACHINES

Catalogo ricambi. ( Valido dalla matricola nr del ) Spare parts catalogue. ( Valid from serial number 2174 dated 06.

COMPRESSORI D ARIA AIR COMPRESSORS

MACCHINE DA CAFFE' AUTOMATICA AUTOMATIC COFFEE MACHINES

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

EVX 800 series is a range of controllers for the management of blast chillers.

Alimentatori LED LED drivers

Denominazione tavola - Table definition Valida per i modelli - Apply to models N tavola RAV RAV4300DC - RAV4350 Table no.

Aerona Air Source Heat Pumps

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

RELAYS E ACCESSORI FUSIBILI E PORTAFUSIBILI

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

c-pro nano RACK & c-pro micro RACK

Tunnel 50 Twin. Catalogo ricambi ( Valido dalla matricola nr del ) Spare parts catalogue ( Valid from serial number 4851 dated 12.

STERILE FILTER UNIT MODEL 1200 COD

Midea Commercial Air Conditioner Malfunction Handbook

INSTALLATION OPERATING & MAINTENANCE MANUAL

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Technical service manual

ALONE. Project No TREN/FP7EN/ ALONE. small scale solar cooling device. Collaborative Project Small or Medium-scale Focused Research Project

INSTALLATION MANUAL. Address card EKAC10B

LISTA RICAMBI / PART LIST

Thermozone AD Corinte

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

MACCHINE DA CAFFE' AUTOMATICA AUTOMATIC COFFEE MACHINES

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Technical Information

Failure code manual. content

Sistema di controllo SIRe

TUBE FILLING & PROCESS SOLUTIONS SERIE

Cool Design for Homes and Offices

1993 WIRING DIAGRAMS Volkswagen Wiring Diagrams. Volkswagen; EuroVan

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

MP-4000 Alarm List (Software version or later)

Nautilus S01HS. Macchina da caffè per capsule monodose. Coffee machine for single serve capsules.

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SMM. Installation Operation Maintenance

Ampio limite di funzionamento, può fare riscaldamento fino a -20 C di temperatura esterna e rinfrescamento fino +43 C di temperatura esterna

How To Build A Powerboat

DISTRIBUTORI ROTANTI ELETTRICI E ELETTRO-IDRAULICI ELECTRO-HYDRAULIC ROTARY COUPLING

A 906 MANUALE PER IL PERSONALE TECNICO SERVICE MANUAL. Includes: Comprende: - Exploded view with spare parts list - Electric diagram

11/2011. Mod: E17/F28A8-N. Production code:

Uninterruptible Power System

Wiring Diagram. Diplomat 400V 3N.

LISTINO PREZZI PRICE LIST 2011 INDICE / CONTENTS

QUADRO DI CONTROLLO / CONTROL BOARD

HP switch LP switch Discharge thermo Comp. Surface thermo

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE


Serie ET / ET Series

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Application Engineering

15. Strumenti di misura - Checking devices 15.1 Burette - Burette

Technical Support Bulletin Nr. 20 Special AC Functions

ZHT / OHT / KHT / NHT / EHT 6

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

MINI CONTATTORI / MINI CONTACTORS

DIABLO VALLEY COLLEGE CATALOG

Split Controller. User Manual SM-SS-F 2009/01/04

Trouble Shooting Guide

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

FRIGORIFERO DA 400 LT PER VINO 400 LT WINE

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

COMMISSIONING OF HVAC SYSTEMS

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections

OXFORD FC. Air/water chiller with integrated free-cooling kw

Porcia, 20 novembre 2012

Motori elettrici corrente continua. DC motors MCC

CGC s Hybrid System Loop Control

Low Profile Unit Cooler

MicroTech III Unit Controller for Water Source Heat Pump Units

INSTALLATION & OPERATION MANUAL MODULAR AIR COOLED CHILLER

, User s Manual

Introduction. If you have further questions Call Hayward s tech service department at

A/C-HEATER SYSTEM - AUTOMATIC

Tahiti, un isola di freschezza. Tahiti, an island of freshness

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

SPARE PARTS CATALOGUE CATALOGO PARTI DI RICAMBIO. PENTOLE ELETTRICHE INDIRETTE 100/150Lt N900 ELECTRIC BOILING PAN INDIRECT HEATING 100/150Lt N900

C Series. 16(5)A at 250V A.C 50Hz. 3A at 30V D.C. L/R=5ms 10 milioni di operazioni a 1 Hz / million operations at 1Hz 1250Vrms at 50Hz

E MODELS USCITA IN OTTONE BRASS OUTLET

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

User s Information/Installation Instructions

Model: DC-A2IO Advanced HVAC Controller

MicroTech III Unit Controller for Water Source Heat Pump Units

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Fundamentals of HVAC Control Systems

Hoshizaki America, Inc.

Condensate water pump with neutralisation system

HVAC Processes. Lecture 7

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Transcription:

2 3 McSmart 16C INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 16C 18275 18275 3 1

MODEL: McSmart 16C 4V/3N~/5Hz RESISTENZA CARTER CRANKCASE HEATER RESISTENZA CARTER CRANKCASE HEATER NOTE: E COMP1-2 OL1-6 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION Q1 PUMP1-2 POMPA ACQUA WATER PUMP HP1-6 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH SW1-2 FAN1-2 VANTILATORI LP1-6 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH DB3A KM1-6 CONTATTORI CONTACTOR DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH QS F1-3 FUSIBILI FUSE TB1-4 MORSETTI TERMINAL BLOCK HEATER INTERRUTTORE EMERGENZA EMERGENCY SWITCH INTERRUTTORE SWITCH PROTEZIONE FASE PHASE PROTECTOR SEZIONATORE MAIN SWITCH RESISTENZA ANTIGELO ANTIFREEZ HEATER RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION MODELLO MODEL McSmart 16C HEATER ALLARME ALARM PCB CORTOCIRCUITARE 12-13 SHORT 12-13 TARATURE TOLLERANCE SETTING SETTAGGI PONTICELLI JUMPER SETTING NOTE: 1: OL1 OL2 OL3 OL4 OL5 OL6 JH1 JH2 2: 3: KM7 18275 3 2 AC/DC ALIMENTAZIONE AC/DC SUPPLY PANNELLO UTENTE USER PANEL SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION McSmart 16C AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18275 3 3

2 3 McSmart 16CR INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 16CR 18282 18282 3 1

MODEL: McSmart 16CR 4V/3N~/5Hz RESISTENZA CARTER CRANKCASE HEATER RESISTENZA CARTER CRANKCASE HEATER NOTE: E COMP1-2 OL1-6 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION Q1 PUMP1-2 POMPA ACQUA WATER PUMP HP1-6 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH SW1-2 FAN1-2 VANTILATORI LP1-6 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH DB3A KM1-6 CONTATTORI CONTACTOR DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH QS F1-3 FUSIBILI FUSE TB1-4 MORSETTI TERMINAL BLOCK 4WV1-2 HEATER INTERRUTTORE EMERGENZA EMERGENCY SWITCH INTERRUTTORE SWITCH PROTEZIONE FASE PHASE PROTECTOR SEZIONATORE MAIN SWITCH VALVOLA A 4 VIE 4 WAYS VALVE RESISTENZA ANTIGELO ANTIFREEZ HEATER RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION MODELLO MODEL McSmart 16CR PCB CORTOCIRCUITARE 15-16 SHORT 15-16 TARATURE TOLLERANCE SETTING SETTAGGI PONTICELLI JUMPER SETTING NOTE: 1: OL1 OL2 OL3 OL4 OL5 OL6 JH1 JH2 2: 3: KM7 HEATER ALLARME ALARM 18282 3 2 AC/DC ALIMENTAZIONE AC/DC SUPPLY PANNELLO UTENTE USER PANEL SENSORE DI SBRINAMENTO 2 DEFROST TEMPERATURE SENSOR 2 SENSORE DI SBRINAMENTO 1 DEFROST TEMPERATURE SENSOR 1 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION McSmart 16CR AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18282 3 3

2 3 McSmart 19C INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 19C 18276 18276 3 1

MODEL: McSmart 19C 4V/3N~/5Hz RESISTENZA CARTER CRANKCASE HEATER RESISTENZA CARTER CRANKCASE HEATER NOTE: E COMP1-2 OL1-6 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION Q1 PUMP1-2 POMPA ACQUA WATER PUMP HP1-6 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH SW1-2 FAN1-2 VANTILATORI LP1-6 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH DB3A KM1-6 CONTATTORI CONTACTOR DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH QS F1-3 FUSIBILI FUSE TB1-4 MORSETTI TERMINAL BLOCK HEATER INTERRUTTORE EMERGENZA EMERGENCY SWITCH INTERRUTTORE SWITCH PROTEZIONE FASE PHASE PROTECTOR SEZIONATORE MAIN SWITCH RESISTENZA ANTIGELO ANTIFREEZ HEATER RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION MODELLO MODEL McSmart 19C HEATER ALLARME ALARM PCB CORTOCIRCUITARE 12-13 SHORT 12-13 TARATURE TOLLERANCE SETTING SETTAGGI PONTICELLI JUMPER SETTING NOTE: 1: OL1 OL2 OL3 OL4 OL5 OL6 JH1 JH2 2: 3: KM7 18276 3 2 AC/DC ALIMENTAZIONE AC/DC SUPPLY PANNELLO UTENTE USER PANEL SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION McSmart 19C AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18276 3 3

2 3 McSmart 19CR INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 19CR 18283 18283 3 1

MODEL: McSmart 19CR 4V/3N~/5Hz RESISTENZA CARTER CRANKCASE HEATER RESISTENZA CARTER CRANKCASE HEATER NOTE: E COMP1-2 OL1-6 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION Q1 PUMP1-2 POMPA ACQUA WATER PUMP HP1-6 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH SW1-2 FAN1-2 VANTILATORI LP1-6 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH DB3A KM1-6 CONTATTORI CONTACTOR DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH QS F1-3 FUSIBILI FUSE TB1-4 MORSETTI TERMINAL BLOCK 4WV1-2 HEATER INTERRUTTORE EMERGENZA EMERGENCY SWITCH INTERRUTTORE SWITCH PROTEZIONE FASE PHASE PROTECTOR SEZIONATORE MAIN SWITCH VALVOLA A 4 VIE 4 WAYS VALVE RESISTENZA ANTIGELO ANTIFREEZ HEATER RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION MODELLO MODEL McSmart 19CR ALLARME ALARM PCB CORTOCIRCUITARE 15-16 SHORT 15-16 TARATURE TOLLERANCE SETTING SETTAGGI PONTICELLI JUMPER SETTING NOTE: 1: OL1 OL2 OL3 OL4 OL5 OL6 JH1 JH2 2: 3: KM7 HEATER 18283 3 2 AC/DC ALIMENTAZIONE AC/DC SUPPLY PANNELLO UTENTE USER PANEL SENSORE DI SBRINAMENTO 2 DEFROST TEMPERATURE SENSOR 2 SENSORE DI SBRINAMENTO 1 DEFROST TEMPERATURE SENSOR 1 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION McSmart 19CR AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18283 3 3

2 3 McSmart 21C INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 21C 18277 18277 3 1

MODEL: McSmart 21C 4V/3N~/5Hz RESISTENZA CARTER CRANKCASE HEATER RESISTENZA CARTER CRANKCASE HEATER NOTE: E COMP1-2 OL1-6 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION Q1 PUMP1-2 POMPA ACQUA WATER PUMP HP1-6 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH SW1-2 FAN1-2 VANTILATORI LP1-6 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH DB3A KM1-6 CONTATTORI CONTACTOR DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH QS F1-2 FUSIBILI FUSE TB1-4 MORSETTI TERMINAL BLOCK PS HEATER INTERRUTTORE EMERGENZA EMERGENCY SWITCH INTERRUTTORE SWITCH PROTEZIONE FASE PHASE PROTECTOR SEZIONATORE MAIN SWITCH PRESS. CONDENSAZIONE COND. PRESSURE SWITCH RESISTENZA ANTIGELO ANTIFREEZ HEATER RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION MODELLO MODEL McSmart 21C HEATER ALLARME ALARM PCB CORTOCIRCUITARE 1-11 SHORT 1-11 TARATURE TOLLERANCE SETTING SETTAGGI PONTICELLI JUMPER SETTING NOTE: 1: OL1 OL2 OL3 OL4 OL5 OL6 JH1 JH2 2: 3: KM7 18277 3 2 AC/DC ALIMENTAZIONE AC/DC SUPPLY PANNELLO UTENTE USER PANEL SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION McSmart 21C 18277 3 3

2 3 McSmart 21CR INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 21CR 18284 18284 3 1

MODEL: McSmart 21CR 4V/3N~/5Hz RESISTENZA CARTER CRANKCASE HEATER RESISTENZA CARTER CRANKCASE HEATER NOTE: E COMP1-2 OL1-6 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION Q1 PUMP1-2 POMPA ACQUA WATER PUMP HP1-6 PRESSOSTAO ALTA PRESSIONE HIGH PRESSURE SWITCH SW1-2 FAN1-2 VANTILATORI LP1-6 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH DB3A KM1-6 CONTATTORI CONTACTOR DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH QS F1-2 FUSIBILI FUSE TB1-4 MORSETTI TERMINAL BLOCK PS J RELE' RELAY HEATER RESISTENZA ANTIGELO ANTIFREEZ HEATER 4WV1 INTERRUTTORE EMERGENZA EMERGENCY SWITCH INTERRUTTORE SWITCH PROTEZIONE FASE PHASE PROTECTOR SEZIONATORE MAIN SWITCH PRESS. CONDENSAZIONE COND. PRESSURE SWITCH VALVOLA A 4 VIE 4 WAYS VALVE RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION MODELLO MODEL McSmart 21CR ALLARME ALARM PCB CORTOCIRCUITARE 11-13 SHORT 11-13 TARATURE TOLLERANCE SETTING SETTAGGI PONTICELLI JUMPER SETTING NOTE: 1: OL1 OL2 OL3 OL4 OL5 OL6 JH1 JH2 2: 3: KM7 HEATER 18284 3 2 AC/DC ALIMENTAZIONE AC/DC SUPPLY PANNELLO UTENTE USER PANEL SENSORE DI SBRINAMENTO 2 DEFROST TEMPERATURE SENSOR 2 SENSORE DI SBRINAMENTO 1 DEFROST TEMPERATURE SENSOR 1 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION McSmart 21CR 18284 3 3

2 3 McSmart 24C INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 24C 18278 18278 3 1

MODEL: McSmart 19C 4V/3N~/5Hz RESISTENZA CARTER CRANKCASE HEATER RESISTENZA CARTER CRANKCASE HEATER NOTE: E COMP1-2 OL1-6 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION Q1 PUMP1-2 POMPA ACQUA WATER PUMP HP1-6 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH SW1-2 FAN1-2 VANTILATORI LP1-6 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH DB3A KM1-6 CONTATTORI CONTACTOR DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH QS F1-2 FUSIBILI FUSE TB1-4 MORSETTI TERMINAL BLOCK PS CP1-2 PROTEZIONE E PROTECTOR HEATER INTERRUTTORE EMERGENZA EMERGENCY SWITCH INTERRUTTORE SWITCH PROTEZIONE FASE PHASE PROTECTOR SEZIONATORE MAIN SWITCH PRESS. CONDENSAZIONE COND. PRESSURE SWITCH RESISTENZA ANTIGELO ANTIFREEZ HEATER RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION MODELLO MODEL McSmart 24C HEATER ALLARME ALARM PCB CORTOCIRCUITARE 12-13 SHORT 12-13 TARATURE TOLLERANCE SETTING SETTAGGI PONTICELLI JUMPER SETTING NOTE: 1: OL1 OL2 OL3 OL4 OL5 OL6 JH1 JH2 2: 3: KM7 18278 3 2 AC/DC ALIMENTAZIONE AC/DC SUPPLY PANNELLO UTENTE USER PANEL SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION McSmart 24C 18278 3 3

2 3 McSmart 24CR INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 24CR 18285 18285 3 1

MODEL: McSmart 24CR 4V/3N~/5Hz RESISTENZA CARTER CRANKCASE HEATER RESISTENZA CARTER CRANKCASE HEATER NOTE: E COMP1-2 OL1-6 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION Q1 PUMP1-2 POMPA ACQUA WATER PUMP HP1-6 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH SW1-2 FAN1-2 VANTILATORI LP1-6 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH DB3A KM1-6 CONTATTORI CONTACTOR DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH PS F1-2 FUSIBILI FUSE CP1-2 PROTEZIONE E PROTECTOR TB1-4 INTERRUTTORE EMERGENZA EMERGENCY SWITCH INTERRUTTORE SWITCH PROTEZIONE FASE PHASE PROTECTOR PRESS. CONDENSAZIONE COND. PRESSURE SWITCH MORSETTI TERMINAL BLOCK RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION 4WV1 4WV1 QS J VALVOLA A 4 VIE 4 WAYS VALVE VALVOLA A 4 VIE 4 WAYS VALVE SEZIONATORE MAIN SWITCH RELE' RELAY MODELLO MODEL McSmart 24CR ALLARME ALARM PCB CORTOCIRCUITARE 14-15 SHORT 14-15 TARATURE TOLLERANCE SETTING SETTAGGI PONTICELLI JUMPER SETTING NOTE: 1: OL1 OL2 OL3 OL4 OL5 OL6 JH1 JH2 2: 3: KM7 HEATER 18285 3 2 AC/DC ALIMENTAZIONE AC/DC SUPPLY PANNELLO UTENTE USER PANEL SENSORE DI SBRINAMENTO 2 DEFROST TEMPERATURE SENSOR 2 SENSORE DI SBRINAMENTO 1 DEFROST TEMPERATURE SENSOR 1 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION McSmart 24CR 18285 3 3

2 3 4 McSmart 32C INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CIRCUITO DI CONTROLLO / CONTROL CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 32C 18279 18279 4 1

QS SEZIONATORE MAIN SWITCH F1-2 FUSIBILI FUSE HT1-4 RESISTENZA CARTER CRANKCASE HEATER TB1-4 MORSETTI TERMINAL BLOCK KM1-12 CONTATTORI CONTACTOR OL1-12 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION DB3A PROTEZIONE FASE PHASE PROTECTOR TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING 1-1 1-2 2-1 2-2 HT 1 HT 2 HT 3 HT 4 111 112 113 114 115 116 117 118 1 McSmart 32C RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION VEDERE Pag. 4 SEE Pag. 4 A 2 PUMP MOTOR 1 PUMP MOTOR 2 RIMUOVERE SENZA POMPE TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING MODELLO MODEL OL1 OL2 OL3 OL4 OL5 OL8 OL11 OL12 18279 4 2

NOTE: 1: 2: 3: KM13 COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR I COMPONENTI ALL'INTERNO DEI PARTICOLARI SONO 4: PART. B&C RISPETTIVAMENTE I COLLEGAMENTI DELLE POMPE ED I CABLAGGI DEL CONTROLLO SOVRACCARICO. SE L'UNITA' E' SPROVVISTA DI POMPE, RIMUOVERE DAL DISEGNO I CABLAGGI, E COLLEGARE LA PORTA 17 ALLA 3 DIRETTAMENTE SUL MORSETTO. COMPONENT INSIDE SECTIONS B&C ARE RISPECTLY PUMPS WIRING AND OVERLOAD FEEDBACK WIRING. IF THE UNIT HAS NO PUMPS, PLEASE REMOVE FROM THA DRAWING THE ABOVE WIRINGS AND PROVIDE TO CONNECT PORT 17 WITH PORT 3 ON THE TERMINAL BLOCK DIRECLY SIMBOLI E DESCRIZIONI & Q1 SEZIONATORE MAIN SWITCH HP1-2 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH Q2 PULSANTE EMERGENZA EMERGENCY BOTTON LP1-2 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH SW1-2 INTERRUTTORE SWITCH DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH DB3A PROTEZIONE FASE PHASE PROTECTOR PS1-2 PRESS. CONDENSAZIONE COND. PRESSURE SWITCH HEATER RESISTENZA ANTIGELO ANTIFREEZ HEATER 4WV1 VALVOLA A 4 VIE 4 WAYS VALVE 18279 McSmart 32C 4 3 AC/DC ALIMENTAZIONE AC/DC SUPPLY ALLARME ALARM MAIN PCB EXTEND PCB PANNELLO UTENTE USER PANEL SETTAGGI PONTICELLI JUMPER SETTING JH1 JH2 SENSORE DI MANDATA E 4 DISCHARGE SENSOR 4 SENSORE DI MANDATA E 3 DISCHARGE SENSOR 3 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE B C

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 1 AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 2 McSmart 32C AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18279 4 4

2 3 4 McSmart 32CR INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CIRCUITO DI CONTROLLO / CONTROL CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 32CR 18286 18286 4 1

QS SEZIONATORE MAIN SWITCH F1-2 FUSIBILI FUSE HT1-4 RESISTENZA CARTER CRANKCASE HEATER TB1-4 MORSETTI TERMINAL BLOCK KM1-12 CONTATTORI CONTACTOR OL1-12 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION DB3A PROTEZIONE FASE PHASE PROTECTOR TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING 1-1 1-2 2-1 2-2 HT 1 HT 2 HT 3 HT 4 111 112 113 114 115 116 117 118 1 McSmart 32CR RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION VEDERE Pag. 4 SEE Pag. 4 A 2 PUMP MOTOR 1 PUMP MOTOR 2 RIMUOVERE SENZA POMPE TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING MODELLO MODEL OL1 OL2 OL3 OL4 OL5 OL8 OL11 OL12 18286 4 2

NOTE: 1: 2: 3: KM13 COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR I COMPONENTI ALL'INTERNO DEI PARTICOLARI SONO 4: PART. B&C RISPETTIVAMENTE I COLLEGAMENTI DELLE POMPE ED I CABLAGGI DEL CONTROLLO SOVRACCARICO. SE L'UNITA' E' SPROVVISTA DI POMPE, RIMUOVERE DAL DISEGNO I CABLAGGI, E COLLEGARE LA PORTA 17 ALLA 3 DIRETTAMENTE SUL MORSETTO. COMPONENT INSIDE SECTIONS B&C ARE RISPECTLY PUMPS WIRING AND OVERLOAD FEEDBACK WIRING. IF THE UNIT HAS NO PUMPS, PLEASE REMOVE FROM THA DRAWING THE ABOVE WIRINGS AND PROVIDE TO CONNECT PORT 17 WITH PORT 3 ON THE TERMINAL BLOCK DIRECLY SIMBOLI E DESCRIZIONI & Q1 SEZIONATORE MAIN SWITCH HP1-2 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH Q2 PULSANTE EMERGENZA EMERGENCY BOTTON LP1-2 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH SW1-2 INTERRUTTORE SWITCH DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH DB3A PROTEZIONE FASE PHASE PROTECTOR PS1-2 PRESS. CONDENSAZIONE COND. PRESSURE SWITCH HEATER RESISTENZA ANTIGELO ANTIFREEZ HEATER 4WV1 VALVOLA A 4 VIE 4 WAYS VALVE 18286 McSmart 32CR 4 3 AC/DC ALIMENTAZIONE AC/DC SUPPLY ALLARME ALARM MAIN PCB EXTEND PCB PANNELLO UTENTE USER PANEL SETTAGGI PONTICELLI JUMPER SETTING JH1 JH2 SENSORE DI SBRINAMENTO 2 DEFROST TEMPERATURE SENSOR 2 SENSORE DI MANDATA E 4 DISCHARGE SENSOR 4 SENSORE DI MANDATA E 3 DISCHARGE SENSOR 3 SENSORE DI SBRINAMENTO 1 DEFROST TEMPERATURE SENSOR 1 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE B C

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 1 AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 2 McSmart 32CR AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18286 4 4

2 3 4 McSmart 4C INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CIRCUITO DI CONTROLLO / CONTROL CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 4C 1828 1828 4 1

QS SEZIONATORE MAIN SWITCH F1-2 FUSIBILI FUSE HT1-4 RESISTENZA CARTER CRANKCASE HEATER TB1-4 MORSETTI TERMINAL BLOCK KM1-12 CONTATTORI CONTACTOR OL1-12 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION DB3A PROTEZIONE FASE PHASE PROTECTOR TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING 1-1 1-2 2-1 2-2 HT 1 HT 2 HT 3 HT 4 111 112 113 114 115 116 117 118 1-1 McSmart 4C RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION VEDERE Pag. 4 SEE Pag. 4 A 1-2 2-1 2-2 PUMP MOTOR 1 PUMP MOTOR 2 RIMUOVERE SENZA POMPE TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING MODELLO MODEL OL1 OL2 OL3 OL4 OL5 OL6 OL8 OL9 OL11 OL12 1828 4 2

NOTE: 1: 2: 3: KM13 COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR I COMPONENTI ALL'INTERNO DEI PARTICOLARI SONO 4: PART. B&C RISPETTIVAMENTE I COLLEGAMENTI DELLE POMPE ED I CABLAGGI DEL CONTROLLO SOVRACCARICO. SE L'UNITA' E' SPROVVISTA DI POMPE, RIMUOVERE DAL DISEGNO I CABLAGGI, E COLLEGARE LA PORTA 17 ALLA 3 DIRETTAMENTE SUL MORSETTO. COMPONENT INSIDE SECTIONS B&C ARE RISPECTLY PUMPS WIRING AND OVERLOAD FEEDBACK WIRING. IF THE UNIT HAS NO PUMPS, PLEASE REMOVE FROM THA DRAWING THE ABOVE WIRINGS AND PROVIDE TO CONNECT PORT 17 WITH PORT 3 ON THE TERMINAL BLOCK DIRECLY SIMBOLI E DESCRIZIONI & Q1 SEZIONATORE MAIN SWITCH HP1-2 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH Q2 PULSANTE EMERGENZA EMERGENCY BOTTON LP1-2 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH SW1-2 INTERRUTTORE SWITCH DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH DB3A PROTEZIONE FASE PHASE PROTECTOR PS1-2 PRESS. CONDENSAZIONE COND. PRESSURE SWITCH HEATER RESISTENZA ANTIGELO ANTIFREEZ HEATER 1828 McSmart 4C 4 3 AC/DC ALIMENTAZIONE AC/DC SUPPLY ALLARME ALARM MAIN PCB EXTEND PCB PANNELLO UTENTE USER PANEL SETTAGGI PONTICELLI JUMPER SETTING JH1 JH2 SENSORE DI MANDATA E 4 DISCHARGE SENSOR 4 SENSORE DI MANDATA E 3 DISCHARGE SENSOR 3 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE B C

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 1-1 1-2 AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 2-1 2-2 McSmart 4C AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 1828 4 4

2 3 4 McSmart 4CR INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CIRCUITO DI CONTROLLO / CONTROL CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 4CR 18287 18287 4 1

QS SEZIONATORE MAIN SWITCH F1-2 FUSIBILI FUSE HT1-4 RESISTENZA CARTER CRANKCASE HEATER TB1-4 MORSETTI TERMINAL BLOCK KM1-12 CONTATTORI CONTACTOR OL1-12 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION DB3A PROTEZIONE FASE PHASE PROTECTOR TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING 1-1 1-2 2-1 2-2 HT 1 HT 2 HT 3 HT 4 111 112 113 114 115 116 117 118 1-1 McSmart 4CR RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION VEDERE Pag. 4 SEE Pag. 4 A 1-2 2-1 2-2 PUMP MOTOR 1 PUMP MOTOR 2 RIMUOVERE SENZA POMPE TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING MODELLO MODEL OL1 OL2 OL3 OL4 OL5 OL6 OL8 OL9 OL11 OL12 18287 4 2

NOTE: 1: 2: 3: KM13 COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR I COMPONENTI ALL'INTERNO DEI PARTICOLARI SONO 4: PART. B&C RISPETTIVAMENTE I COLLEGAMENTI DELLE POMPE ED I CABLAGGI DEL CONTROLLO SOVRACCARICO. SE L'UNITA' E' SPROVVISTA DI POMPE, RIMUOVERE DAL DISEGNO I CABLAGGI, E COLLEGARE LA PORTA 17 ALLA 3 DIRETTAMENTE SUL MORSETTO. COMPONENT INSIDE SECTIONS B&C ARE RISPECTLY PUMPS WIRING AND OVERLOAD FEEDBACK WIRING. IF THE UNIT HAS NO PUMPS, PLEASE REMOVE FROM THA DRAWING THE ABOVE WIRINGS AND PROVIDE TO CONNECT PORT 17 WITH PORT 3 ON THE TERMINAL BLOCK DIRECLY SIMBOLI E DESCRIZIONI & Q1 SEZIONATORE MAIN SWITCH HP1-2 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH Q2 PULSANTE EMERGENZA EMERGENCY BOTTON LP1-2 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH SW1-2 INTERRUTTORE SWITCH DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH J 1-2 RELE' RELAY PS1-2 PRESS. CONDENSAZIONE COND. PRESSURE SWITCH DB3A PROTEZIONE FASE PHASE PROTECTOR 4WV1 VALVOLA A 4 VIE 4 WAYS VALVE HEATER RESISTENZA ANTIGELO ANTIFREEZ HEATER 18287 McSmart 4CR 4 3 AC/DC ALIMENTAZIONE AC/DC SUPPLY ALLARME ALARM MAIN PCB EXTEND PCB PANNELLO UTENTE USER PANEL SETTAGGI PONTICELLI JUMPER SETTING JH1 JH2 SENSORE DI SBRINAMENTO 2 DEFROST TEMPERATURE SENSOR 2 SENSORE DI MANDATA E 4 DISCHARGE SENSOR 4 SENSORE DI MANDATA E 3 DISCHARGE SENSOR 3 SENSORE DI SBRINAMENTO 1 DEFROST TEMPERATURE SENSOR 1 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE B C

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 1-1 1-2 AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 2-1 2-2 McSmart 4CR AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18287 4 4

2 3 4 McSmart 4CR INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CIRCUITO DI CONTROLLO / CONTROL CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 4CR 18287 18287 4 1

QS SEZIONATORE MAIN SWITCH F1-2 FUSIBILI FUSE HT1-4 RESISTENZA CARTER CRANKCASE HEATER TB1-4 MORSETTI TERMINAL BLOCK KM1-12 CONTATTORI CONTACTOR OL1-12 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION DB3A PROTEZIONE FASE PHASE PROTECTOR TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING 1-1 1-2 2-1 2-2 HT 1 HT 2 HT 3 HT 4 111 112 113 114 115 116 117 118 1-1 McSmart 4CR RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION VEDERE Pag. 4 SEE Pag. 4 A 1-2 2-1 2-2 PUMP MOTOR 1 PUMP MOTOR 2 RIMUOVERE SENZA POMPE TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING MODELLO MODEL OL1 OL2 OL3 OL4 OL5 OL6 OL8 OL9 OL11 OL12 18287 4 2

NOTE: 1: 2: 3: KM13 COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR I COMPONENTI ALL'INTERNO DEI PARTICOLARI SONO 4: PART. B&C RISPETTIVAMENTE I COLLEGAMENTI DELLE POMPE ED I CABLAGGI DEL CONTROLLO SOVRACCARICO. SE L'UNITA' E' SPROVVISTA DI POMPE, RIMUOVERE DAL DISEGNO I CABLAGGI, E COLLEGARE LA PORTA 17 ALLA 3 DIRETTAMENTE SUL MORSETTO. COMPONENT INSIDE SECTIONS B&C ARE RISPECTLY PUMPS WIRING AND OVERLOAD FEEDBACK WIRING. IF THE UNIT HAS NO PUMPS, PLEASE REMOVE FROM THA DRAWING THE ABOVE WIRINGS AND PROVIDE TO CONNECT PORT 17 WITH PORT 3 ON THE TERMINAL BLOCK DIRECLY SIMBOLI E DESCRIZIONI & Q1 SEZIONATORE MAIN SWITCH HP1-2 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH Q2 PULSANTE EMERGENZA EMERGENCY BOTTON LP1-2 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH SW1-2 INTERRUTTORE SWITCH DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH J 1-2 RELE' RELAY PS1-2 PRESS. CONDENSAZIONE COND. PRESSURE SWITCH DB3A PROTEZIONE FASE PHASE PROTECTOR 4WV1 VALVOLA A 4 VIE 4 WAYS VALVE HEATER RESISTENZA ANTIGELO ANTIFREEZ HEATER 18287 McSmart 4CR 4 3 AC/DC ALIMENTAZIONE AC/DC SUPPLY ALLARME ALARM MAIN PCB EXTEND PCB PANNELLO UTENTE USER PANEL SETTAGGI PONTICELLI JUMPER SETTING JH1 JH2 SENSORE DI SBRINAMENTO 2 DEFROST TEMPERATURE SENSOR 2 SENSORE DI MANDATA E 4 DISCHARGE SENSOR 4 SENSORE DI MANDATA E 3 DISCHARGE SENSOR 3 SENSORE DI SBRINAMENTO 1 DEFROST TEMPERATURE SENSOR 1 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE B C

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 1-1 1-2 AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 2-1 2-2 McSmart 4CR AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18287 4 4

2 3 4 McSmart 5C INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CIRCUITO DI CONTROLLO / CONTROL CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 5C 18281 18281 4 1

QS SEZIONATORE MAIN SWITCH F1-2 FUSIBILI FUSE HT1-4 RESISTENZA CARTER CRANKCASE HEATER TB1-4 MORSETTI TERMINAL BLOCK KM1-12 CONTATTORI CONTACTOR OL1-12 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION DB3A PROTEZIONE FASE PHASE PROTECTOR TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING 1-1 1-2 2-1 2-2 HT 1 HT 2 HT 3 HT 4 111 112 113 114 115 116 117 118 1-1 McSmart 5C RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION VEDERE Pag. 4 SEE Pag. 4 A 1-2 2-1 2-2 PUMP MOTOR 1 PUMP MOTOR 2 RIMUOVERE SENZA POMPE TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING MODELLO MODEL OL1 OL2 OL3 OL4 OL5 OL6 OL8 OL9 OL11 OL12 18281 4 2

NOTE: 1: 2: 3: KM13 COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR I COMPONENTI ALL'INTERNO DEI PARTICOLARI SONO 4: PART. B&C RISPETTIVAMENTE I COLLEGAMENTI DELLE POMPE ED I CABLAGGI DEL CONTROLLO SOVRACCARICO. SE L'UNITA' E' SPROVVISTA DI POMPE, RIMUOVERE DAL DISEGNO I CABLAGGI, E COLLEGARE LA PORTA 17 ALLA 3 DIRETTAMENTE SUL MORSETTO. COMPONENT INSIDE SECTIONS B&C ARE RISPECTLY PUMPS WIRING AND OVERLOAD FEEDBACK WIRING. IF THE UNIT HAS NO PUMPS, PLEASE REMOVE FROM THA DRAWING THE ABOVE WIRINGS AND PROVIDE TO CONNECT PORT 17 WITH PORT 3 ON THE TERMINAL BLOCK DIRECLY SIMBOLI E DESCRIZIONI & Q1 SEZIONATORE MAIN SWITCH HP1-2 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH Q2 PULSANTE EMERGENZA EMERGENCY BOTTON LP1-2 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH SW1-2 INTERRUTTORE SWITCH DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH DB3A PROTEZIONE FASE PHASE PROTECTOR PS1-2 PRESS. CONDENSAZIONE COND. PRESSURE SWITCH HEATER RESISTENZA ANTIGELO ANTIFREEZ HEATER CT1-4 PROTEZIONE INTERNA COMP. COMP. INNER PROTECTOR 18281 McSmart 5C 4 3 AC/DC ALIMENTAZIONE AC/DC SUPPLY ALLARME ALARM MAIN PCB EXTEND PCB PANNELLO UTENTE USER PANEL SETTAGGI PONTICELLI JUMPER SETTING JH1 JH2 SENSORE DI MANDATA E 4 DISCHARGE SENSOR 4 SENSORE DI MANDATA E 3 DISCHARGE SENSOR 3 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE B C

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 1-1 1-2 AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 2-1 2-2 McSmart 5C AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18281 4 4

2 3 4 McSmart 5CR INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CIRCUITO DI CONTROLLO / CONTROL CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 5CR 18288 18288 4 1

QS SEZIONATORE MAIN SWITCH F1-2 FUSIBILI FUSE HT1-4 RESISTENZA CARTER CRANKCASE HEATER TB1-4 MORSETTI TERMINAL BLOCK KM1-12 CONTATTORI CONTACTOR OL1-12 PROTEZIONE SOVRACCARICO OVERLOAD PROTECTION DB3A PROTEZIONE FASE PHASE PROTECTOR TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING 1-1 1-2 2-1 2-2 HT 1 HT 2 HT 3 HT 4 111 112 113 114 115 116 117 118 1-1 McSmart 5CR RIMUOVERE CON VARIATORE DI VELOCITA' REMOVE WITH FAN SPEED MODULATION VEDERE Pag. 4 SEE Pag. 4 A 1-2 2-1 2-2 PUMP MOTOR 1 PUMP MOTOR 2 RIMUOVERE SENZA POMPE TARATURE RELE' DI SOVRACCARICO OVERLOAD RELAY SETTING MODELLO MODEL OL1 OL2 OL3 OL4 OL5 OL6 OL8 OL9 OL11 OL12 18288 4 2

NOTE: 1: 2: 3: KM13 COLLEGAMENTI SUL CAMPO FIELD INSTALLATION COLLEGAMENTI IN FABBRICA FACTORY WIRING CONTATTORE CONTROLLO BOILER BOILER CONTROL CONTACTOR I COMPONENTI ALL'INTERNO DEI PARTICOLARI SONO 4: PART. B&C RISPETTIVAMENTE I COLLEGAMENTI DELLE POMPE ED I CABLAGGI DEL CONTROLLO SOVRACCARICO. SE L'UNITA' E' SPROVVISTA DI POMPE, RIMUOVERE DAL DISEGNO I CABLAGGI, E COLLEGARE LA PORTA 17 ALLA 3 DIRETTAMENTE SUL MORSETTO. COMPONENT INSIDE SECTIONS B&C ARE RISPECTLY PUMPS WIRING AND OVERLOAD FEEDBACK WIRING. IF THE UNIT HAS NO PUMPS, PLEASE REMOVE FROM THA DRAWING THE ABOVE WIRINGS AND PROVIDE TO CONNECT PORT 17 WITH PORT 3 ON THE TERMINAL BLOCK DIRECLY SIMBOLI E DESCRIZIONI & Q1 SEZIONATORE MAIN SWITCH HP1-2 PRESSOSTATO ALTA PRESSIONE HIGH PRESSURE SWITCH Q2 PULSANTE EMERGENZA EMERGENCY BOTTON LP1-2 PRESSOSTATO BASSA PRESSIONE LOW PRESSURE SWITCH SW1-2 INTERRUTTORE SWITCH DPS PRESS. DIFFERENZIALE ACQUA DIFFERENTIAL PRESSURE SWITCH J 1-2 RELE' RELAY PS1-2 PRESS. CONDENSAZIONE COND. PRESSURE SWITCH DB3A PROTEZIONE FASE PHASE PROTECTOR 4WV1 VALVOLA A 4 VIE 4 WAYS VALVE HEATER RESISTENZA ANTIGELO ANTIFREEZ HEATER CT1-4 PROTEZIONE INTERNA COMP. COMP. INNER PROTECTOR 18288 McSmart 5CR 4 3 AC/DC ALIMENTAZIONE AC/DC SUPPLY ALLARME ALARM MAIN PCB EXTEND PCB PANNELLO UTENTE USER PANEL SETTAGGI PONTICELLI JUMPER SETTING JH1 JH2 SENSORE DI SBRINAMENTO 2 DEFROST TEMPERATURE SENSOR 2 SENSORE DI MANDATA E 4 DISCHARGE SENSOR 4 SENSORE DI MANDATA E 3 DISCHARGE SENSOR 3 SENSORE DI SBRINAMENTO 1 DEFROST TEMPERATURE SENSOR 1 SENSORE DI MANDATA E 2 DISCHARGE SENSOR 2 SENSORE DI MANDATA E 1 DISCHARGE SENSOR 1 SENSORE TEMPERATURA AMBIENTE OUTDOOR AMBIENT SENSOR TEMPERATURA ACQUA USCENTE LEAVING WATER TEMPERATURE TEMPERATURA ACQUA ENTRANTE ENTERING WATER TEMPERATURE B C

4V/3N~/5Hz FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 1-1 1-2 AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION FCS VARIATORE DI VELOCITA' VENT. FAN SPEED MODULATION 2-1 2-2 McSmart 5CR AL TRASDUTTORE DI PRESSIONE TO PRESSURE SENSOR DA USARE CON VARIATORE DI VELOCITA' VERSIONE CHILLER TO USE WITH FAN SPEED MODULATION CHILLER VERSION 18288 4 4