What are the basic electrical safety issues and remedies in solar photovoltaic installations?



Similar documents
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

City of Riverside Building & Safety Division Phone: (951)

County of Riverside Building and Safety Department

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

How To Plan Out An Array Of Solar Panels

City of San Diego Residential Photovoltaic Systems Inspection Guidelines

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Ontario Electrical Safety Code 25 th Edition/ 2012

PV and the Electrical Code Page 1 PV and the Electrical Code

Solar Photovoltaic (PV) Systems

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

YINGLI SOLAR PV MODULES Installation and User Manual

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

Solar Panel Installations

Los Angeles Fire Department Requirement No. 96 SOLAR PHOTOVOLTAIC SYSTEM

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

CITY OF LOS ANGELES CALIFORNIA

Doe Residence kw DC Roof Mounted Photovoltaic System

Top Commercial / Residential Electrical Requirements *

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Electrical Grounding. Appendix C

Submittal Requirements for Solar Photovoltaic Installations 10 kw or Less in One and Two Family (Duplex) Dwellings

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Installation Guide Content for P250xV-240 microinverters

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

ELECTRICAL INSPECTION BULLETIN (Effective )

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Checklist Testing and inspection without interconnection

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

Safety and Installation Instructions for AC Modules

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

Solar Kit. Complete solution to optimize your photovoltaic system

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Request for Proposals for Photovoltaic System Installation

Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10

NEC 2014 Code Changes

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

RESIDENTIAL PHOTOVOLTAIC SUBMITTAL REQUIREMENTS

AC Module Installation Guide Content

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

YINGLI SOLAR PV MODULES Installation and User Manual

Residential Electrical System Aging Research Project. Dave Dini Sr. Research Engineer Underwriters Laboratories

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

TOP 10 CHANGES 2013 CALIFORNIA ELECTRICAL CODE 2013 CALIFORNIA ENERGY CODE (ELECTRICAL)

Installation Instructions

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Title: Grounding and Bonding Rev-01

Solar Home System Kit Quality Standards

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Entrances to and from Electrical Equipment Rooms

Short Circuit Current Calculations

Atlanta Chapter IEEE Industry Applications Society

CHAPTER 2 EXAMPLES AND TABLES

AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Conext Grid Tie Solar Inverter Conext TX 2800 NA Conext TX 3300 NA Conext TX 3800 NA Conext TX 5000 NA

TECHNICAL SPECIFICATIONS

1 GENERAL 4 2 DEFINITIONS 4 3 STANDARDS FOR INSTALLATION 4 4 LICENSING Extra Low Voltage (ELV) Low Voltage (LV) 5

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

Photovoltaic System Grounding

Fronius IG Plus. The next generation grid-connected PV inverter

Photovoltaic Solar Energy Unit EESFB

Requirements for Electrical Installations

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES

Section B: Electricity

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Solar Circuit Protection Application Guide. Complete and reliable solar circuit protection

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

YSmart Technology Co.,Ltd

Inverter / Charger Installation General Operations and AC and DC Connections

Charging what can be more simple? SAE J1772

Construction Electrical Terminology. Electricians

FAQs-Main switchboard design criteria

CalMod Design-Build Electrification Services

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Complete Solar Photovoltaics Steven Magee. Health and Safety

ADM1TE 5/30A DIN rail single phase two wire energy meter

Current Transformers

Electrical Resistance Resistance (R)

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

CSUN Crystalline Silicon PV Module Products Installation Manual (IEC Version)

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Transcription:

What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety

Topics Covered Photovoltaic System What it is and What it does How it does it Where it is installed It s Equipment Definitions Layout of a Simple Photovoltaic System Risk of Fire, Personal Injury and Electric Shock Hazard Fundamentals Fire and Electric Shock Hazard Safety Issues & Remedies: Workmanship Equipment Wiring Label and Markings Maintenance Electrical Code Compliance

Photovoltaic System What, How, and Where Photovoltaic systems convert renewable solar energy into useable electric energy. For example, a solar panel exposed to Sunlight will generate direct current and voltage that can supply building loads (i.e., lighting, appliances, etc.) in lieu of utility power. In order to get good sun exposure, solar modules/panels are typically installed on roofs, but they may also be installed on the ground (i.e., mega power systems), on poles or trellises in parking lots, and even recently, on building walls.

Photovoltaic System - Equipment A photovoltaic solar system typically consist of the following equipment: Modules Inverter(s) Combiner(s) Disconnecting Means (i.e., switches or disconnects) Overcurrent Protective Devices (i.e., fuses or circuit breakers) Conductors (or Cables) Connectors Raceways Load Center (s) Equipment and System Ground A Utility Meter

Definitions Inverter Equipment used to change voltage level or waveform, or both, of electrical energy. They may be referred to as a Power Conditioning Unit or a Power Conversion System. This equipment changes dc input to an ac output. Module A complete, environmentally protected unit consisting of solar cells, optics, and other components, exclusive of tracker, designed to generate dc power when exposed to sunlight. Panel - A collection of modules mechanically fastened to gether, wired, and designed to provide a field-installable unit. Photovoltaic (PV) Source Circuit Circuits between modules and from modules to the common connection point(s) (i.e., Combiner) of the dc system. Combiner A box intended to combine together parallel wires from PV source circuits into a larger wire commonly referred to as PV output circuit. It may incorporate overcurrent protective devices, disconnects and other components. PV Output Circuit Circuit conductors between the PV source circuit(s) and the inverter or dc utilization equipment.

Definitions Continued Overcurrent Protective Device A device such as a fuse or circuit breaker intended to respond to an overcurrent condition (i.e., overload, short circuit, or ground fault) in a circuit and de-energize the circuit upon activation. Disconnecting Means A device, or group of devices, or other means by which the conductors or equipment can be disconnected from their source of supply. Ground-Fault Protection (GFP) A system or device intended to provide protection of equipment from damaging line-to-ground fault currents by operating to cause a disconnecting means to open all ungrounded conductors of the faulted circuit. The current level of operation of these devices are typically above 30 ma. Raceway - An enclosed channel (i.e., conduit) of metal or nonmetallic materials designed expressly for holding wires, cables, or bus bars.

Layout of A Simple Photovoltaic System

Fire, Personal Injury and Electric Shock Hazard Fundamentals

Risk of Fire or Personal Injury Fundamentals A circuit is considered to be able to start a fire or cause a personal injury if it is able to deliver no less than 2 volts and any one of the following conditions: An available continuous power level of 240 voltamperes or more, or A reactive energy level of 20 joules or more A fire may also be started by excessive temperature due to overload or arcing effect.

Risk of Electric Shock Fundamentals A risk of Electric shock is present when accessible live parts and/or the dead metal parts of equipment have a current magnitude above 5 ma and a voltage magnitude exceeding one of the values shown in the table below.

Fire and Electric Shock Hazard Safety Issues

Type of Failures and Their Remedies Human and Workmanship Equipment Wiring Labels and Marking Maintenance

An Example of Human Failure

An Actual Recorded Fire Incident

An Example of Workmanship Failure

How Many Wires Can You Fit in an Electrical Box?

Human and Workmanship Remedies The installer should be a Contractor licensed by the State of California to perform such a work (i.e., B, C 10, C46, etc.). Follow equipment listing installation instructions. Comply with the Electrical Code. ANSI/NECA 1-2006, Standard Practice for Good Workmanship in Electrical Contracting, Is one example of the many ANSI standards that describe neat and workmanlike installations.

Equipment Failures

Equipment Failures: Modules Cell Short Circuit Cell Open Circuit Interconnect Open Circuit Open circuit Short Circuit Glass Breakage Delamination Hot spot (Reverse-Biased) DC Arc Fault By-Pass Diode Encapsulant Bonding Path Resistance Reverse Current Overload Corrosion Strain Relief Insulation Weather

Equipment Failure: Inverter Capacitor Bridge Circuit Insulation Output Overload DC Input Miss Wiring Ventilation Termination Component Short or Open Circuit Loss of Control Circuit Surge Harmonic Synchronization Overvoltage Weather Ground Fault

Equipment Failures Continued Combiner Insulation Loss of Control Circuit Termination Undersized Bus Disconnecting Means Undersized Insulation Inadequate Withstand Current Overcurrent Protective Devices Undersized Inadequate Interrupting Capacity Connectors Inadequate Voltage Rating Lockable vs. non-lockable Make first break last ground pin in multi-pin connectors (plug)

Equipment Failure Remedies Use appropriate overcurrent protective device type and rating. Assure that the maximum open circuit voltage does not exceed the equipment voltage rating. Assure that the maximum modules short circuit current does not exceed the inverter maximum input short circuit current rating. Equipment are listed by a recognized testing agency according to approved test standards and labeled or identified as listed. Typical recognized approved Test Standards are: UL 1741, PV Inverters, combiners and charge controllers UL 1703, Flat Plate PV Modules and Panels IEEE 1547, Standard for Interconnecting Distributed Resources With Electric Power Systems IEEE 1547.1, Standard for Conformance Test Procedures for Equipment Interconnecting Distributed Resources with Electric Power Systems

Equipment Failures Remedies Continued There are currently 15 other PV related Standards in the development stage. Examples of some of these standards are: UL 2703, Outline of Investigation for Rack Mounting Systems and Clamping devices for Flat-Plate PV Modules and Panels UL 4703, Outline of Investigation for PV Wire UL 2579, Outline of Investigation for PV System Low-Voltage Fuses UL 508I, Outline of Investigation for Manual Disconnect Switches Intended for Use in PV Systems UL 6703A, Outline of Investigation for Multi-Pole Connectors for use in PV Systems UL 1699B, Outline of Investigation for PV DC Arc-fault Circuit Protection

Wiring Failures

Wiring failures on a PV system can be result of any of the following conditions Short-Circuit Ground-Fault Current Ground-Fault Voltage Excessive DC Open-Circuit Voltage Open-Circuit Overload Over Heat (i.e., ambient, solar radiation, harmonics, irradiance factor, etc.) Lack of, Improper or Inadequate Grounding (Equipment or System) Undersized Raceway Improper Terminations Improper connector Intermix of Dissimilar Metals (i.e., Cu and Al) Improper Binding Screws or Splicing Devices Improper Expansion Joints Rodents

An Example Wiring Failure

A Fire Due to Improper Wiring

Wiring Remedies Use Wire size suitable for the short circuit current of modules including the irradiance factor and solar exposure de-rating effect. Use appropriate type and rated overcurrent protective devices. Include the effect of continues operation of the system and the ambient temperature. Coordinate terminal temperature ratings of various equipment terminals with that of wiring insulation. Use wiring insulation that is suitable for the exposed environments (wet, UV, corrosive, etc.). Assure wire stranding is compatible with wiring termination (i.e., fine strand vs. standard strand). Do not intermix different wiring materials (CU vs. AL). Provide properly sized equipment grounding that is based on circuit overcurrent protective device rating and terminates into a fitting that is rated and sized appropriately.

Wiring Remedies continued Provide properly sized system grounding electrode conductor for grounded system that is based on PV source ungrounded (energized) conductors. With some exceptions, provide dc GFP for PV system. The GFP must be sized based on KW rating of the system by the manufacturer or the design engineer. Be aware that the GFP does not protect against electric shock hazard. Provide additional AC GFP when connecting to a service equipment or a feeder that has a GFP All PV system are required to have equipment grounding. Only a grounded system is required to have a system grounding as well as an equipment grounding. Use properly sized raceway to avoid loss of insulation during installation. Limit the total number of bends in the raceway to no more than 360 deg. Adjust the wiring ampacity when more than three energized conductors are run in a raceway. Assure that the raceway is suitable for the environment encountered (i.e., temperature, physical strength, etc.).

Labels and Markings Due to inherent hazard of PV system and need for proper maintenance, numerous markings are required by listed products and the electrical code. Labels and Markings may provide information on the components of the system, such as Module, PV system operating condition, Identifying a component, Or a warning referring to possible shock hazard (i.e., upon activation of GFP in a PV system or an open disconnect with both terminals still energized, etc.), Overvoltage, device ratings, Presence of all sources, etc.

Typical Electrical Code and State Fire Marshall (SFM) Required Markings in a PV System

Maintenance PV system would require different maintenance during it s life time. Disconnecting Means are required to be installed at various PV equipment (i.e., inverters) to accommodate their removal when required for maintenance or replacement. PV modules needs to be cleaned of dust to maintain it s operating efficiency.

Electrical Code Compliance Installations in the State of California are required to comply with the 2010 California Electrical Code that is based on 2008 National Electrical Code. Article 690 of the Electrical Code specifically applies to Solar Photovoltaic Systems. Wherever the requirements of other articles of the code and Article 690 differ, the requirements of Article 690 apply. Other Articles and Sections of the Code (i.e., Article 240, and Sections 705.14,.16,.32,.143) as referred by article 690 also apply.

The End