Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide



Similar documents
Cisco Catalyst 3750X. Rapid EqualLogic Configuration Series Implementation Guide. Dell Storage Engineering April 2014

Building Architectures to Solve Business Problems

Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters

Chapter 7 Lab 7-1, Configuring Switches for IP Telephony Support

Dell EqualLogic Best Practices Series. Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference

What is VLAN Routing?

Virtual PortChannel Quick Configuration Guide

Configuring Network QoS

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Geschreven door Administrator woensdag 13 februari :37 - Laatst aangepast woensdag 13 februari :05

Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version

CISCO CATALYST 3550 Series Switches

Brocade to Cisco Comparisons

Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches

Lab 3.5.1: Basic VLAN Configuration (Instructor Version)

Installing the Cisco Nexus 1000V for Microsoft Hyper-V

FlexPod Express with Microsoft Windows Server 2012 Hyper-V Implementation Guide

Switch Quick Configuration CLI Guide for

Configuring Cisco Nexus 5000 Switches Course DCNX5K v2.1; 5 Days, Instructor-led

- EtherChannel - Port Aggregation

Configuring Server Load Balancing

How To Install An At-S100 (Geo) On A Network Card (Geoswitch)

Enabling Remote Access to the ACE

Lab Use Network Inspector to Observe STP Behavior

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

Configuring EtherChannels

Lab 7-1 Configuring Switches for IP Telephony Support

How To Configure Link Aggregation On Supermicro Switch 2 And 3 (Lan) On A Microsoft Vlan 2 And Vlan 3 (Vlan) (Lan 2) (Vlans) (Lummer) (Powerline) (

Using MLAG in Dell Networks

An Oracle White Paper October How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches

Deploying Silver Peak VXOA Physical And Virtual Appliances with Dell EqualLogic Isolated iscsi SANs including Dell 3-2-1

Link Aggregation Interoperability of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS based Switches. By Bruce Holmes

Basic Router and Switch Instructions (Cisco Devices)

Implementing Cisco Data Center Unified Fabric Course DCUFI v5.0; 5 Days, Instructor-led

How To Configure InterVLAN Routing on Layer 3 Switches

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version Rev. B

IP SAN Best Practices

Abstract. Avaya Solution & Interoperability Test Lab

Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual

Network Scenarios Pagina 1 di 35

TotalCloud Phone System

Configuring the Firewall Management Interface

Abstract. Avaya Solution & Interoperability Test Lab

Configuring the Fabric Interconnects

Configuring EtherChannels

Unified Access Point Administrator's Guide

Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation

Lab Review of Basic Router Configuration with RIP. Objective. Background / Preparation. General Configuration Tips

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.

Configuring Role-Based Access Control

AT-S60 Version Management Software for the AT-8400 Series Switch. Software Release Notes

Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices

How Do I Upgrade Firmware and Save Configurations on PowerConnect Switches?

Lab Advanced Telnet Operations

Configuring Network Address Translation

Fundamentals of Switching

RESILIENT NETWORK DESIGN

StorSimple Appliance Quick Start Guide

Configuring LLDP, LLDP-MED, and Location Service

Configuring NetFlow. Information About NetFlow. NetFlow Overview. Send document comments to CHAPTER

Monitoring Network Traffic Using SPAN

Abstract. Avaya Solution & Interoperability Test Lab

Configuring NetFlow. Information About NetFlow. NetFlow Overview. Send document comments to CHAPTER

EMC Data Domain Management Center

16-PORT POWER OVER ETHERNET WEB SMART SWITCH

Configuring iscsi Multipath

Port Trunking. Contents

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario

Lab Load Balancing Across Multiple Paths

Unified Access Point (AP) Administrator s Guide

Configuring the Switch with the CLI Setup Program

CCNA DATA CENTER BOOT CAMP: DCICN + DCICT

Connect the Host to attach to Fast Ethernet switch port Fa0/2. Configure the host as shown in the topology diagram above.

QoS Queuing on Cisco Nexus 1000V Class-Based Weighted Fair Queuing for Virtualized Data Centers and Cloud Environments

Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch

Lab 2 - Basic Router Configuration

Configuring DHCP Snooping

SOFTWARE LICENSE LIMITED WARRANTY

Lab 3.3 Configuring QoS with SDM

VLAN Interoperability

- Virtual LANs (VLANs) and VTP -

Using LiveAction with Cisco Secure ACS (TACACS+ Server)

Management Software. User s Guide AT-S88. For the AT-FS750/24POE Fast Ethernet Smart Switch. Version Rev. B

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Configuring QoS and Per Port Per VLAN QoS

Configuring Auto-QoS

Abstract. Avaya Solution & Interoperability Test Lab

Design and Implementation Guide. Data Center Design Guide: Implement McAfee Next Generation Firewall for the Perimeter

LotWan Appliance User Guide USER GUIDE

HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide

3.1 Connecting to a Router and Basic Configuration

CCT vs. CCENT Skill Set Comparison

Deploying ACLs to Manage Network Security

SDN CENTRALIZED NETWORK COMMAND AND CONTROL

Port Trunking. Contents

Active Fabric Manager (AFM) Plug-in for VMware vcenter Virtual Distributed Switch (VDS) CLI Guide

Switching in an Enterprise Network

Cisco Data Centre: Introducing Cisco Data Center Networking

ADVANCED NETWORK CONFIGURATION GUIDE

Transcription:

Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering October 2015 A Dell Deployment and Configuration Guide

Revisions Date February 2013 October 2013 March 2014 May 2014 October 2015 Description Initial release Updated for firmware 6.0(2)N1(2) Updated for firmware 7.0(0)N1(1) and added DCB with iscsi TLV configuration. Updated DCB bandwidth, jumbo frames configuration Added entry to now properly disable DCB THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. 2013 2015 Dell Inc. All rights reserved. Dell, the DELL logo, and the DELL badge are trademarks of Dell Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims any proprietary interest in the marks and names of others. 2 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

Table of contents Revisions... 2 1 Introduction... 5 1.1 Document conventions... 5 1.2 Audience... 5 1.3 Switch details... 5 1.4 Cabling diagram... 6 2 Dell recommended switch configuration... 7 2.1 Hardware configuration... 7 2.2 Delete startup configuration... 7 2.3 Running the basic system configuration... 7 2.4 Disabling Data Center Bridging (DCB)... 9 2.5 Configure the vpc domain... 9 2.6 Configure Port Channel... 9 2.7 Enable link level flow control (802.3x)... 10 2.8 Configure portfast on edge ports... 10 2.9 Enable VLAN... 10 2.10 Enable switch ports... 11 2.11 Configure the Nexus policy engine... 11 2.11.1 Configure CoS for iscsi... 11 2.11.2 Define a QoS map for iscsi... 11 2.11.3 Define a QoS policy map for iscsi... 11 2.11.4 Define a network QoS class map... 11 2.11.5 Define a no-drop policy map and enable jumbo frames... 11 2.11.6 Define a queuing class-map... 12 2.11.7 Define a queuing policy-map... 12 2.12 Apply the Nexus policies... 12 2.13 Save configuration... 12 2.14 Configure additional switch... 12 3 Configure Data Center Bridging (DCB) (optional)... 13 3.1 Enable DCB... 13 3.2 Enable VLAN... 13 3 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

3.3 Configure the vpc domain... 13 3.4 Configure Port Channel... 13 3.5 Configure portfast on edge ports... 14 3.5.1 Configure VLANs for iscsi... 14 3.6 Configure the Nexus policy engine... 14 3.6.1 Define a QoS map for iscsi... 15 3.6.2 Define a QoS policy map for iscsi... 15 3.6.3 Define a queuing class-map... 15 3.6.4 Define a network QoS class map... 15 3.6.5 Define a queuing policy-map... 15 3.6.6 Define a no-drop policy map and enable jumbo frames... 15 3.7 Apply the Nexus policies... 16 3.8 Save configuration... 16 3.9 Configure Additional Switch... 16 3.10 Disabling DCB (optional)... 16 Additional resources... 17 4 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

1 Introduction This document illustrates how to configure Cisco Nexus 5548UP switches for use with Dell PS Series storage using Dell best practices. The recommended configuration uses link aggregation groups (LAGs) and Virtual Port Channel (vpc) for inter-switch connections. For information on PS Series SAN design recommendations, see the EqualLogic Configuration Guide. 1.1 Document conventions Table 1 lists the formatting conventions used in this document. Table 1 Document conventions Format Description Example Bold User input Dell>enable Italic Placeholder or variable your password <Italic> <brackets> Separate variables <ip address> <mask> 1.2 Audience This switch configuration guide describes a verified configuration following Dell best practices for a PS Series iscsi SAN and is intended for storage or network administrators and deployment personnel. 1.3 Switch details Table 2 provides an overview of the switch configuration. Table 2 Switch specifications Cisco Nexus 5548UP Switch vendor Cisco Switch model Nexus 5548UP Switch firmware v7.1(0)n1(1b) Note: For proper functionality, the switch must be at the firmware version shown in the table above before proceeding with this configuration. Using previous firmware versions may have unpredictable results. The latest firmware updates and documentation can be found at: www.cisco.com (requires login. 5 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

1.4 Cabling diagram The cabling diagram shown below represents the Dell recommend method for deploying your servers and PS Series arrays. Figure 1 Cabling diagram 6 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

2 Dell recommended switch configuration Follow the steps in this section to configure two Cisco Nexus 5548UP switches with a vpc interconnect. The switches are interconnected using four of the 10Gb ports configured as the vpc link. Note: The configuration steps in this section are only recommended when the switch is used as a dedicated SAN for iscsi traffic (not shared with LAN traffic). 2.1 Hardware configuration 1. Power on both switches. 2. Connect a serial cable to the management port. 3. Using PuTTY or another terminal utility, open a serial connection session to the switch. 4. Open your terminal emulator and configure it to use the serial port (usually COM1 but this may vary depending on your system). Configure serial communications for 9600,N,8,1 and no flow control. 5. Connect the cables between switch 1 and switch 2 as shown in Figure 1, for ports 1-4. This will be used as your vpc link. 2.2 Delete startup configuration Note: This example assumes a switch at its default configuration settings. Using the write erase command will set the startup configuration file to its default settings. You should always back up your configuration settings prior to performing any configuration changes. switch>enable switch#write erase Warning: This command will erase the startup-configuration Do you wish to proceed anyway? (y/n) [n] y switch# reload WARNING: this command will reboot the system Do you want to continue? (y/n) [n] y Note: The switch will reboot. 2.3 Running the basic system configuration The following steps use the setup utility to configure connectivity for basic management of the system. After the switch fully reboots, the following prompts will appear: Abort Power On Auto Provisioning and continue with normal setup?(yes/no)[n]: y ---- System Admin Account Setup ---- Do you want to enforce secure password standard (yes/no): yes Enter the password for "admin": my password Confirm the password for "admin": my password 7 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

---- Basic System Configuration Dialog ---- This setup utility will guide you through the basic configuration of the system. Setup configures only enough connectivity for management of the system. Please register Cisco Nexus 5000 Family devices promptly with your supplier. Failure to register may affect response times for initial service calls. Nexus devices must be registered to receive entitled support services. Press Enter at anytime to skip a dialog. Use ctrl-c at anytime to skip the remaining dialogs. Would you like to enter the basic configuration dialog (yes/no): yes Create another login account (yes/no) [n]: n Configure read-only SNMP community string (yes/no) [n]: n Configure read-write SNMP community string (yes/no) [n]: n Enter the switch name : my switch name Continue with Out-of-band (mgmt0) management configuration? (yes/no) [y]: y Mgmt0 IPv4 address : my IP address Mgmt0 IPv4 netmask : my netmask Configure the default gateway? (yes/no) [y]: y IPv4 address of the default gateway : my gateway Enable the telnet service? (yes/no) [n]: y Enable the ssh service? (yes/no) [y]: n Configure the ntp server? (yes/no) [n]: n Enter basic FC configurations (yes/no) [n]: n The following configuration will be applied: switchname my switch name interface mgmt0 ip address my ip address my netmask no shutdown exit vrf context management ip route 0.0.0.0/0 my gateway exit telnet server enable no ssh server enable Would you like to edit the configuration? (yes/no) [n]: n Use this configuration and save it? (yes/no) [y]: y [########################################] 100% Copy complete, now saving to disk (please wait)... Log in with the credentials created in the previous steps. Note: For Data Center Bridging (DCB) configuration, skip to section 3. 8 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

2.4 Disabling Data Center Bridging (DCB) Note: All steps in this section are required in order to properly disable DCB. These steps are also required when upgrading from previous versions to this new version v7.1(0)n1(1b). switch# configure switch(config)#lldp tlv-select dcbxp switch(config)#copy running-config startup-config switch(config)#no lldp tlv-select dcbxp switch(config)#exit switch#copy running-config startup-config Note: The above steps needed due to CSCuo63486 LLDP - link err-disabled upon reload when dcbx tlv is disabled. 2.5 Configure the vpc domain switch# configure switch(config)#feature lacp switch(config)#feature vpc switch(config)#vpc domain 1 switch(config-vpc-domain)#peer-keepalive destination peer IP address --------:: Management VRF will be used as the default VRF ::-------- Note: For the peer IP address, use the management IP address of the partner switch. switch(config-vpc-domain)#exit 2.6 Configure Port Channel switch(config)# interface port-channel 1 switch(config-if)# switchport mode trunk switch(config-if)# spanning-tree port type network switch(config-if)# vpc peer-link Please note that spanning tree port type is changed to network port type on vpc peer-link. This will enable spanning tree Bridge Assurance on vpc peer-link provided the STP Bridge Assurance (which is enabled by default) is not disabled. switch(config-if)# exit switch(config)# interface ethernet 1/1-4 switch(config-if-range)# switchport mode trunk switch(config-if-range)# channel-group 1 mode active switch(config-if-range)# exit 9 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

switch(config)# interface port-channel 1 switch(config-if)#priority-flow-control mode off switch(config-if)# flowcontrol send on switch(config-if)# flowcontrol receive on switch(config-if)# exit 2.7 Enable link level flow control (802.3x) You must perform this step for each individual port that is connected to a storage controller or a host interface port, or you can specify a range of ports to configure. switch(config)#interface ethernet 1/5-32 switch(config-if-range)#priority-flow-control mode off switch(config-if-range)#flowcontrol send on switch(config-if-range)#flowcontrol receive on switch(config-if-range)#exit 2.8 Configure portfast on edge ports switch(config)#interface ethernet 1/5-32 switch(config-if-range)#spanning-tree port type edge Warning: edge port type (portfast) should only be enabled on ports connected to a single host. Connecting hubs, concentrators, switches, bridges, etc to this interface when edge port type (portfast) is enabled, can cause temporary bridging loops. Use with CAUTION. Edge Port Type (Portfast) will be configured in 28 interfaces due to the range commend but will only have effect when the interfaces are in a non-trunking mode. switch(config-if-range)#exit 2.9 Enable VLAN The following example uses VLAN 101 and configures a range of ports. Any valid VLAN (between 2 4094) may be substituted. switch(config)# vlan 101 switch(config-vlan)# exit switch(config)# interface ethernet 1/5-32 Note: Switch ports 1 4 are part of port-channel 1 and are not included in the above range. switch(config-if-range)# switchport access vlan 101 switch(config-if-range)# exit 10 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

2.10 Enable switch ports The following example enables a range of ports. If preferred, you may enable individual ports as needed. switch(config)# interface ethernet 1/1-32 switch(config-if-range)# shutdown switch(config-if-range)# no shutdown switch (config-if-range)# exit 2.11 Configure the Nexus policy engine The following example configures iscsi traffic for Class of Service (CoS) 4 and Quality of Service (QoS) group 3. 2.11.1 Configure CoS for iscsi Repeat this step for each individual interface connected to host and array controller ports, or specify a range of ports to configure. switch(config)# interface ethernet 1/5-32 switch(config-if-range)# untagged cos 4 switch(config-if-range)# exit 2.11.2 Define a QoS map for iscsi switch(config)# class-map type qos class-iscsi switch(config-cmap-qos)# match cos 4 switch(config-cmap-qos)# exit 2.11.3 Define a QoS policy map for iscsi switch(config)# policy-map type qos policy-qos switch(config-pmap-qos)# class type qos class-iscsi switch(config-pmap-c-qos)#set qos-group 3 switch(config-pmap-c-qos)# exit switch(config-pmap-qos)# exit 2.11.4 Define a network QoS class map switch(config)# class-map type network-qos class-iscsi switch(config-cmap-nq)# match qos-group 3 switch(config-cmap-nq)# exit 2.11.5 Define a no-drop policy map and enable jumbo frames switch(config)# policy-map type network-qos policy-nq switch(config-pmap-nq)# class type network-qos class-iscsi switch(config-pmap-nq-c)# mtu 9216 switch(config-pmap-nq-c)# pause no-drop 11 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

switch(config-pmap-nq-c)# exit Note: The following steps are optional and will enable jumbo MTU for the default class (non-iscsi traffic). switch(config-pmap-nq)#class type network-qos class-default switch(config-pmap-nq-c)#mtu 9216 switch(config-pmap-nq-c)# exit switch(config-pmap-nq)# exit 2.11.6 Define a queuing class-map switch(config)# class-map type queuing class-iscsi switch(config-cmap-que)# match qos-group 3 2.11.7 Define a queuing policy-map switch(config-cmap-que)# policy-map type queuing policy-queuing switch(config-pmap-que)# class type queuing class-default switch(config-pmap-c-que# bandwidth percent 5 switch(config-pmap-c-que)# class type queuing class-fcoe switch(config-pmap-c-que))# bandwidth percent 0 switch(config-pmap-c-que)# class type queuing class-iscsi switch(config-pmap-c-que)# bandwidth percent 95 switch(config-pmap-c-que)# exit switch(config-pmap-que)# exit 2.12 Apply the Nexus policies switch(config)# system qos switch(config-sys-qos)# service-policy type qos input policy-qos switch(config-sys-qos)# service-policy type queuing output policy-queuing switch(config-sys-qos)# service-policy type queuing input policy-queuing switch(config-sys-qos)# service-policy type network-qos policy-nq switch(config-sys-qos)# exit switch(config)# exit 2.13 Save configuration switch#copy running-config startup-config 2.14 Configure additional switch Repeat the commands from sections 2.1 through 2.13 to configure the second switch. 12 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

3 Configure Data Center Bridging (DCB) (optional) To enable DCB mode on the switch, use the procedures in this section. Note: This section assumes a new switch that has a default startup configuration file. Always back up the startup configuration file prior to making any configuration changes. Note: This section enables Data Center Bridging for implementing a converged network (LAN and SAN traffic sharing the same switch fabric). Hosts connecting to PS Series iscsi storage must have a supported converged network adapter (CNA). 3.1 Enable DCB switch# configure switch(config)#lldp tlv-select dcbxp switch(config)# exit switch#copy running-config startup-config 3.2 Enable VLAN The following example uses VLAN 100 for SAN storage and VLAN 200 for other traffic. Any valid VLAN (between 2 4094) may be substituted. switch(config)# vlan 100,200 switch(config-vlan)# exit Note: Switch ports 1-4 are part of port-channel 1 and are not included in the above range. 3.3 Configure the vpc domain switch# configure switch(config)#feature lacp switch(config)#feature vpc switch(config)#vpc domain 1 switch(config-vpc-domain)#peer-keepalive destination peer IP address --------:: Management VRF will be used as the default VRF ::-------- Note: For the peer IP address, use the management IP address of the partner switch. switch(config-vpc-domain)#exit 3.4 Configure Port Channel switch(config)# interface port-channel 1 switch(config-if)# switchport mode trunk 13 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

switch(config-if)# switchport trunk allowed vlan 100,200 switch(config-if)# spanning-tree port type network switch(config-if)# vpc peer-link Please note that spanning tree port type is changed to network port type on vpc peer-link. This will enable spanning tree Bridge Assurance on vpc peer-link provided the STP Bridge Assurance (which is enabled by default) is not disabled. switch(config-if)# exit switch(config)# interface ethernet 1/1-4 switch(config-if-range)# switchport mode trunk switch(config-if-range)# switchport trunk allowed vlan 100,200 switch(config-if-range)# channel-group 1 mode active switch(config-if-range)# exit 3.5 Configure portfast on edge ports switch(config)#interface ethernet 1/5-32 switch(config-if-range)#spanning-tree port type edge Warning: edge port type (portfast) should only be enabled on ports connected to a single host. Connecting hubs, concentrators, switches, bridges, etc to this interface when edge port type (portfast) is enabled, can cause temporary bridging loops. Use with CAUTION. Edge Port Type (Portfast) will be configured in 28 interfaces due to the range commend but will only have effect when the interfaces are in a non-trunking mode. switch(config-if-range)#exit 3.5.1 Configure VLANs for iscsi Repeat this step for each individual interface connected to host and array controller ports, or specify a range of ports to configure. switch(config)# interface ethernet 1/5-32 switch(config-if-range)# switchport mode trunk switch(config-if-range)# switchport trunk allowed vlan 100,200 switch(config-if-range)#exit 3.6 Configure the Nexus policy engine The following subsections configure iscsi traffic for Class of Service (CoS) 4 and Quality of Service (QoS) group 4. 14 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

3.6.1 Define a QoS map for iscsi switch(config)# class-map type qos match-all class-iscsi switch(config-cmap-qos)# match protocol iscsi switch(config-cmap-qos)# match cos 4 switch(config-cmap-qos)# exit 3.6.2 Define a QoS policy map for iscsi switch(config)# policy-map type qos iscsi-in-policy switch(config-pmap-qos)# class class-iscsi switch(config-pmap-c-qos)# set qos-group 4 switch(config-pmap-c-qos)#exit switch((config-pmap-qos)# exit 3.6.3 Define a queuing class-map switch(config)# class-map type queuing class-iscsi switch(config-cmap-que)# match qos-group 4 switch(config-cmap-que)# exit 3.6.4 Define a network QoS class map switch(config)# class-map type network-qos class-iscsi switch(config-cmap-nq)# match qos-group 4 switch(config-cmap-nq)# exit 3.6.5 Define a queuing policy-map Switch(config)# policy-map type queuing iscsi-in-policy switch(config-pmap-que)# class type queuing class-default switch(config-pmap-c-que# bandwidth percent 50 switch(config-pmap-c-que)# class type queuing class-fcoe switch(config-pmap-c-que))# bandwidth percent 0 switch(config-pmap-c-que)# class type queuing class-iscsi switch(config-pmap-c-que)# bandwidth percent 50 switch(config-pmap-c-que)# exit switch(config-pmap-que)# exit 3.6.6 Define a no-drop policy map and enable jumbo frames switch(config)# policy-map type network-qos iscsi-nq-policy switch(config-pmap-nq)# class type network-qos class-iscsi switch(config-pmap-nq-c)# set cos 4 switch(config-pmap-nq-c)# mtu 9216 switch(config-pmap-nq-c)# pause no-drop switch(config-pmap-nq-c)# exit 15 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

Note: The following steps are optional and will enable jumbo MTU for the default class (non-iscsi traffic). switch(config-pmap-nq)#class type network-qos class-default switch(config-pmap-nq-c)#mtu 9216 switch(config-pmap-nq-c)# exit switch(config-pmap-nq)# exit 3.7 Apply the Nexus policies switch(config)# system qos switch(config-sys-qos)# service-policy type qos input iscsi-in-policy switch(config-sys-qos)# service-policy type queuing input iscsi-in-policy switch(config-sys-qos)# service-policy type queuing output iscsi-in-policy switch(config-sys-qos)# service-policy type network-qos iscsi-nq-policy switch(config-sys-qos)# exit switch(config)# exit 3.8 Save configuration switch#copy running-config startup-config 3.9 Configure Additional Switch Repeat the commands from sections 3.1 through 3.8 to configure the second switch. 3.10 Disabling DCB (optional) Note: With the current Cisco Nexus firmware, it is not possible to fully disable DCB functionality correctly. Using the configuration steps in section 2 of this document results in a proper non-dcb environment. In addition, disabling LLDP support can effectively prevent the negotiation of DCB by preventing the transmission of DCBx frames. However, disabling LLDP may also reduce functionality necessary for other protocols. Only disable LLDP if instructed by Dell Support. The following example disables LLDP support on ports 1 through 32. switch#configure switch(config)#interface ethernet 1/1-32 switch(config-if-range)# no lldp receive switch(config-if-range)# no lldp transmit 16 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs

Additional resources Dell.com/support is focused on meeting your needs with proven services and support. Support.cisco.com provides support and information regarding Cisco networking products. DellTechCenter.com is an IT Community where you can connect with Dell customers and Dell employees for the purpose of sharing knowledge, best practices, and information about Dell products and your installations. Referenced or recommended Dell publications: Dell EqualLogic Configuration Guide: http://en.community.dell.com/techcenter/storage/w/wiki/equallogic-configuration-guide.aspx Dell Storage Compatibility Matrix: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/20438558/download.aspx For PS Series best practices white papers, reference architectures, and sizing guidelines for enterprise applications and SANs, refer to: http://en.community.dell.com/techcenter/storage/w/wiki/2660.equallogic-technical-content 17 SCG1006 Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs