HEARING SOLUTIONS catalog 13
Hearing Solutions 3 Series Feature Chart 4 Feature Summary 6 Wi Series Feature Chart 14 Feature Summary 16 Xino Xino Feature Chart 24 Xino Feature Summary 26 Xino Tinnitus Feature Chart 32 Xino Tinnitus Feature Summary 33 SoundLens Feature Summary 38 TOUR / IGNITE SurfLink Feature Summary 52
2 PATIENT DRIVEN PERFORMANCE TESTED
3 Series Our 3 Series lineup includes a newly styled RIC 312, mini BTE 312, and a BTE 13. All three feature everything you and your patients love about our popular wireless hearing aids along with a new, more tactile control switch, updated compression strategy, new, patientrequested color options and much more. Wi SERIES XINO MINI RICS 3 Series Feature Chart 4 3 Series Feature Summary 6 3 Series RIC 312 8 3 Series RIC 312 AP 9 3 Series mini BTE 312 3 Series BTE 13 11 DEEP CANAL INSTRUMENTS SOUNDLENS TOUR/IGNITE SURFLINK Accessories 3
3 Series Sound Imaging Binaural Spatial Mapping VIBRANT Optimal high-resolution sound imaging with frequency shaping in all 16 channels and 16 bands Premium Ear-to-Ear Processing Wi SERIES W I R E L E S S Machine Noise Wind Directionality Synchronized User Controls Binaural Telephone Mode Volume Memory SurfLink Accessory Compatibility SurfLink Mobile SurfLink Programmer SurfLink Media SurfLink Remote XINO MINI RICS SOUNDLENS DEEP CANAL INSTRUMENTS 3 Series FEATURE CHART iq Boost PureWave Feedback Eliminator Acoustic Scene Analyzer Voice iq 2 Noise Reduction Strength AudioScapes Machine Noise Speech in Noise Wind Quiet Speech Noise Premium 16-channel environmental adaptation with 5 levels of personalization Maximum (db) AudioScape Adaptation Levels 5 Spectral iq TOUR/IGNITE SURFLINK Accessories SoundPoint Self Learning Swap Fit 3D Speech Mapping All 3 Series Models Include: Ergonomic Switch to Adjust Volume and Memory ISO Compression Strategy SnapFit Receivers (for RIC products) InVision Directionality Automatic Telephone Solutions Live Speech Mapping Advanced Memories (Music, TV, Relax, T-Coil, Binaural Processing Off) T 2 On Demand Programming 4
ACTIVE High-resolution sound imaging with frequency shaping in 12 channels and 12 bands SOCIAL Frequency shaping in 8 channels and 8 bands Advanced Ear-to-Ear Processing Advanced 12-channel environmental adaptation with 3 levels of personalization Select 8-channel environmental adaptation with 2 levels of personalization Moderate (8dB) Light (6dB) 3 on/off HydraShield 2 In-Situ Audiometry Auto Path Verify Comfort Data Logging 4 Memories * Wireless accessories and features are not available in 3 Series,, and. 5
3 SERIES Feature Summary 3 Series products are available with and without wireless capabilities. 3 Series product names contain an i to signify wireless technology i, i and i. IRIS Technology leverages a unique ear-to-ear communication protocol. Binaural Spatial Mapping* applies the combined speed and power of multiple dual-core platforms to achieve parallel processing benefits. This innovative protocol queries, analyzes, and maps the acoustic space surrounding the patient, applying the appropriate signal processing strategy for directionality and noise management. Voice iq 2 nearly doubles the noise reduction capability of our leading noise reduction and speech preservation system while still maintaining speech. Voice iq 2 : Instantly applies variable noise adaptation in all channels between each pause Has been proven to reduce listening effort and cognitive fatigue when used in tandem with InVision Directionality** Provides up to db of noise reduction JustTalk,* a mode on our new SurfLink Mobile, enables true hands-free phone conversations by turning the wearer s 3 Series hearing aids into both the cell phone microphone and receiver. A new control switch gives users a simple, tactile way to control volume and change memories. Users will enjoy more dynamic and personalized sound with 3 Series new ISO Compression. The 312 RIC features SnapFit receivers, which offer easier receiver connection and ensure greater stability. Unlike competing technologies that apply frequency compression broadly, our frequency lowering technology, Spectral iq, is designed to enhance real-time audibility by intelligently identifying high-frequency speech cues, then replicating them in lower frequencies. This allows 3 Series to maintain important frequency relationships, retaining the sound quality that comes from harmonic distribution, while providing audibility for high-frequency speech cues for patients that may have previously been considered unaidable. Thanks to Self Learning, 3 Series gradually and automatically learns patient volume control preferences in each active memory, which helps reduce the number of manual volume adjustments patients need to make. *Features only available when hearing aids are ordered with wireless functionality. ** Sarampalis, A., Kalluri, S., Edwards, B., Hafter, E. (09, October). Objective measures of listening effort: Effects of background noise and noise reduction. Journal of Speech, Language, and Hearing Research, 52, 12-12. 6
Activated via SurfLink Remote, our iq Boost* feature allows patients to enable aggressive noise reduction while optimizing sound quality in extremely noisy situations. 3 Series wouldn t be a Starkey product without our PureWave Feedback Eliminator. This leading technology ensures wide fitting ranges and a fast response to more complex feedback. HydraShield 2 Omniphobic nano-coating provides unprecedented resistance against wax, oils and everyday moisture. Our Swap Fit fitting function allows you to transfer patient settings from their current Starkey product to a new one enabling more time for fine-tuning and counseling. With Synchronized User Adjustments* patients can use a single hearing instrument to adjust volume or memory for the pair eliminating the need to manually change two instruments. Binaural Telephone Mode** places the phone-side hearing aid in Automatic Telephone Response or Telecoil mode while attenuating the off-side hearing aid. InVision Directionality in 3 Series hearing aids together with Voice iq 2, our leading directional system is designed to enhance speech audibility, even in complex listening environments. Voice Indicators alert your patients to the status of their hearing aid, low battery, memory and telephone modes in their choice of male or female voices in a wide variety of languages. Automatic Telephone Solutions (ATS) automatically detects telephone use and adjusts to the optimal acoustic frequency response for telephone listening. Bring the benefits of telehealth to your practice with our On Demand options. Each one is designed to elevate your interaction with patients and provide a better way for you to deliver care. Includes T 2 On Demand, Audiology On Demand and innovative applications that work with the ipad, iphone and ipod Touch. ipad, iphone and ipod Touch are registered trademarks of Apple Inc. Color Guide Standard Colors Champagne Sterling Bronze Slate Espresso Black Bright Colors Blue Ice Fuchsia Fabulous Blue Pacific Red Hot Pink Pixie Purple Pop 7
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) RIC 312 RECEIVER-IN-CANAL Matrices: 115/, / Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA Gain Data Gain Data 0 Measurement 2cc 2cc Peak OSPL (db SPL) 115 125 1 HFA OSPL (db SPL) 9 115 RTF OSPL (db SPL) 116 125 2 0 1K 2K 4K 8K 3 Series RIC 312 (gray) and 3 Series RIC 312 (black). Peak Gain (db) 62 71 HFA Full-On Gain (db) 44 54 RTF Full-On Gain (db) 53 62 Frequency Range (Hz) -70-70 -70-70 OSPL FOG 1 Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 32 41 38 0 00 OSPL (gray) and Full-On Gain (black) curves for the 3 Series RIC 312 at 115/. Harmonic Distortion 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Induction Coil Sensitivity OSPL FOG HFA SPLITS (ANSI) (db SPL) 86 93 1 MASL (IEC) (db SPL) 91 Battery Current (ma) 1.7* 1.7* 2.0* 2.0* Idle Current (ma) 1.3* 1.3* 1.4* 1.4* 0 00 OSPL (gray) and Full-On Gain (black) curves for the 3 Series RIC 312 at /. Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 5-7* 5-7* 4-7* 4-7* * Results for wireless products will vary based on wireless usage. 8
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) Matrices: 123/, 1/ Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 RIC 312 AP RECEIVER-IN-CANAL ABSOLUTE POWER DATA Gain Data Gain Data 2cc 2cc Measurement 123 131 1 137 Peak OSPL (db SPL) 116 125 HFA OSPL (db SPL) 126 136 RTF OSPL (db SPL) 67 78 Peak Gain (db) 0 2 0 1K 2K 4K 8K 53 64 HFA Full-On Gain (db) 64 75 RTF Full-On Gain (db) 3 Series RIC 312 AP (gray), 3 Series RIC 312 AP (black) fitting ranges. - - 50-50 - 4 Frequency Range (Hz) OSPL FOG 1.6 1.6 Reference Test Frequency (khz) 1 HFA Frequencies (khz) 39 51 48 61 Reference Test Gain (db) Harmonic Distortion 0 00 <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) OSPL (gray) and Full-On Gain (black) curves for the 3 Series RIC 312 AP at 123/. <3 <3 <3 <3 Hz (%) Induction Coil Sensitivity OSPL FOG 1 95 2 HFA SPLITS (ANSI) (db SPL) 1 93 4 MASL (IEC) (db SPL) 1.2* 1.2* 1.4* 1.4* Battery Current (ma) 1.1* 1.1* 1.2* 1.2* Idle Current (ma) 0 00 Estimated Battery Life for 16-Hour Day 6-8* 6-8* 4-6* 4-6* 312 Zinc Air (days) OSPL (gray) and Full-On Gain (black) curves for the 3 Series RIC 312 AP at 1/. * Results for wireless products will vary based on wireless usage. 9
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) mini BTE 312 BEHIND-THE-EAR Matrix: 126/65 Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA Earhook Thin Tube (Size 3+, Occluded) 0 Measurement 2cc 2cc Peak OSPL (db SPL) 126 131 124 HFA OSPL (db SPL) 118 8 RTF OSPL (db SPL) 1 112 2 0 1K 2K 4K 8K Peak Gain (db) 65 64 68 3 Series mini BTE 312 fitting range. HFA Full-On Gain (db) 52 RTF Full-On Gain (db) 69 57 Frequency Range (Hz) - 70-70 - 70-70 OSPL FOG 85 75 135 125 Reference Test Frequency (khz) 1.6 1.6 65 55 115 5 HFA Frequencies (khz) 45 95 35 85 Reference Test Gain (db) 41 53 31 37 25 75 15 65 0 00 OSPL (gray) and Full-On Gain (black) curves for the 3 Series mini BTE 312 with Earhook. Harmonic Distortion 0 Hz (%) <5 <5 <2 <2 0 Hz (%) <3 <3 <1 <1 Hz (%) <3 <3 <2 <2 OSPL FOG Induction Coil Sensitivity 85 1 75 HFA SPLITS (ANSI) (db SPL) 97 87 65 55 MASL (IEC) (db SPL) 92 86 45 35 Battery Current (ma) 1.3* 1.3* 1.3* 1.3* 25 15 0 00 OSPL (gray) and Full-On Gain (black) curves for the 3 Series mini BTE 312 with Thin Tube. Idle Current (ma) 1.2* 1.2* 1.2* 1.2* Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 9-11* 9-11* 9-11* 9-11* * Results for wireless products will vary based on wireless usage.
FOG OSPL (db) (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) MATRIX: 126/65 Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 13 BTE 13 BEHIND-THE-EAR DATA Earhook Thin Tube (Size 3+, Occluded) 2cc 2cc Measurement 0 126 131 121 124 Peak OSPL (db SPL) 119 8 HFA OSPL (db SPL) 1 112 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 65 63 68 Peak Gain (db) 59 52 HFA Full-On Gain (db) 3 Series BTE 13 fitting range. 57 RTF Full-On Gain (db) -70-70 -70-70 Frequency Range (Hz) Wireless BTE 13 126/65 Earhook OSPL FOG 1.6 1.6 Reference Test Frequency (khz) 85 75 135 125 65 115 1.0,1.6, 1.0,1.6, HFA Frequencies (khz) 55 5 45 95 42 55 31 37 Reference Test Gain (db) 35 85 25 75 Harmonic Distortion 15 0 00 65 <5 <4 <2 <2 0 Hz (%) <3 <4 <1 <1 0 Hz (%) <3 <3 <2 <2 Hz (%) OSPL (gray) and Full-On Gain (black) curves for the 3 Series BTE 13 with Earhook. Wireless BTE13 121/63 Thintube Induction Coil Sensitivity OSPL FOG 85 1 2 87 HFA SPLITS (ANSI) (db SPL) 75 86 MASL (IEC) (db SPL) 65 55 1.7* 1.7* 1.7* 1.7* Battery Current (ma) 45 35 1.3* 1.3* 1.3* 1.3* Idle Current (ma) 25 15 0 00 Estimated Battery Life for 16-Hour Day 9-11* 9-11* 9-11* 9-11* 13 Zinc Air (days) OSPL (gray) and Full-On Gain (black) curves for the 3 Series BTE 13 with Thin Tube. * Results for wireless products will vary based on wireless usage. 11
12 THERE is MORE TO OUR WIRELESS
3 Series The success of Starkey s Wi Series wireless hearing aids in the marketplace proves that simplicity and clarity win every time. From the ease of true wireless programming to the quality of their sound to the convenience of our compatible SurfLink accessories, Wi Series wireless hearing aids help make listening effortless again. Wi Series Feature Chart 14 Wi Series Feature Summary 16 ITE 18 Wi SERIES XINO MINI RICS DEEP CANAL INSTRUMENTS SOUNDLENS HS 19 ITC CIC 21 TOUR/IGNITE SURFLINK Accessories 13
3 Series Sound Imaging Binaural Spatial Mapping VIBRANT Optimal high-resolution sound imaging with frequency shaping in all 16 channels and 16 bands Premium Ear-to-Ear Processing Wi SERIES W I R E L E S S Machine Noise Wind Directionality Synchronized User Controls Binaural Telephone Mode Volume Memory SurfLink Accessory Compatibility SurfLink Mobile SurfLink Programmer SurfLink Media XINO MINI RICS SOUNDLENS DEEP CANAL INSTRUMENTS Wi SERIES FEATURE CHART SurfLink Remote iq Boost PureWave Feedback Eliminator Acoustic Scene Analyzer Voice iq 2 Noise Reduction Strength AudioScapes Machine Noise Speech in Noise Wind Quiet Speech Premium 16-channel environmental adaptation with 5 levels of personalization Maximum (db) Noise AudioScape Adaptation Levels 5 Spectral iq TOUR/IGNITE SoundPoint Self Learning Swap Fit 3D Speech Mapping All Wi Series Models Include: SURFLINK Accessories InVision Directionality ( on CICs) Automatic Telephone Solutions Live Speech Mapping Advanced Memories (Music, TV, Relax, T-Coil, Binaural Processing Off) Indicators (Level-Dependent Speech, Level-Dependent Tone) T 2 On Demand Programming 14
ACTIVE SOCIAL High-resolution sound imaging with frequency shaping in 12 channels and 12 bands Frequency shaping in 8 channels and 8 bands Advanced Ear-to-Ear Processing Advanced 12-channel environmental adaptation with 3 levels of personalization Select 8-channel environmental adaptation with 2 levels of personalization Moderate (8dB) Light (6dB) 3 on/off Self Check In-Situ Audiometry Auto Path Verify Comfort Data Logging 4 Memories 15
Wi SERIES Feature Summary IRIS Technology leverages a unique ear-to-ear communication protocol. Binaural Spatial Mapping applies the combined speed and power of multiple dual-core platforms to achieve parallel processing benefits. This innovative protocol queries, analyzes, and maps the acoustic space surrounding the patient, applying the appropriate signal processing strategy for directionality and noise management. Voice iq 2 nearly doubles the noise reduction capability of our leading noise reduction and speech preservation system while still maintaining speech. Voice iq 2 : Instantly applies variable noise adaptation in all channels between each pause Has been proven to reduce listening effort and cognitive fatigue when used in tandem with InVision Directionality* Provides up to db of noise reduction Unlike competing technologies that apply frequency compression broadly, our frequency lowering technology, Spectral iq, is designed to enhance real-time audibility by intelligently identifying high-frequency speech cues, then replicating them in lower frequencies. This allows Wi Series to maintain important frequency relationships, retaining the sound quality that comes from harmonic distribution, while providing audibility for high-frequency speech cues for patients that may have previously been considered unaidable. Activated via SurfLink Remote, our iq Boost feature allows patients to enable aggressive noise reduction while optimizing sound quality in extremely noisy situations. Thanks to Self Learning, Wi Series gradually and automatically learns patient volume control preferences in each active memory, which helps reduce the number of manual volume control adjustments patients need to make. Wi Series wouldn t be a Starkey product without our PureWave Feedback Eliminator. This leading technology ensures wide fitting ranges and a fast response to more complex feedback. * Sarampalis, A., Kalluri, S., Edwards, B., Hafter, E. (09, October). Objective measures of listening effort: Effects of background noise and noise reduction. Journal of Speech, Language, and Hearing Research, 52, 12-12. 16
Our Swap Fit fitting function allows you to transfer patient settings from their current Starkey product to a new one enabling more time for fine-tuning and counseling. With Synchronized User Adjustments patients can use a single hearing instrument to adjust volume or memory for the pair eliminating the need to manually change two instruments. Binaural Telephone Mode places the phone-side hearing aid in Automatic Telephone Response or Telecoil mode while attenuating the off-side hearing aid. InVision Directionality in Wi Series hearing aids together with Voice iq 2, our leading directional system is designed to enhance speech audibility, even in complex listening environments. Voice Indicators alert your patients to the status of their hearing aid, low battery, memory and telephone modes in their choice of male or female voices in a wide variety of languages. Automatic Telephone Solutions (ATS) automatically detects telephone use and adjusts to the optimal acoustic frequency response for telephone listening. Bring the benefits of telehealth to your practice with our On Demand options. Each one is designed to elevate your interaction with patients and provide a better way for you to deliver care. Includes T 2 On Demand, Audiology On Demand and innovative applications that work with the ipad, iphone and ipod Touch. 17
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) ITE IN-THE-EAR Matrices: 115/, 123/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery SIZE: 13 DATA 0 2 0 1K 2K 4K 8K Measurement ITE 115/ ITE 123/ 2cc 2cc Peak OSPL (db SPL) 115 124 123 1 HFA OSPL (db SPL) 116 RTF OSPL (db SPL) 116 128 Peak Gain (db) 58 68 Wi Series ITE fitting range. HFA Full-On Gain (db) 46 53 RTF Full-On Gain (db) 54 66 Wi Series ITE 2cc Frequency Range (Hz) - 60-00 - 00-5 OSPL FOG Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 33 41 39 53 Harmonic Distortion 0 00 OSPL (gray) and Full-On Gain (black) curves for the Wi Series ITE at 115/. OSPL FOG X Series ITE 2cc 1 Attack and Release Time () Test Mode 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Attack Time (ms) Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 95 1 MASL (IEC) (db SPL) 83 95 0 00 OSPL (gray) and Full-On Gain (black) curves for the Wi Series ITE at 123/. Battery Current (ma) 1.22 1.22 1.22 1.22 Idle Current (ma) 1.14 1.15 1.13 1.13 Estimated Battery Life for 16-Hour Day 13 Zinc Air (days) 12-16* 12-16* 12-16* 12-16* * Results for wireless products will vary based on wireless usage. 18
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery SIZE: 312 HS HALF-SHELL DATA HS / HS 115/ 0 2cc 2cc Measurement 119 115 124 Peak OSPL (db SPL) 5 9 HFA OSPL (db SPL) 111 116 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 49 58 Peak Gain (db) 36 46 HFA Full-On Gain (db) Wi Series HS fitting range. 43 53 RTF Full-On Gain (db) - 00-70 - 60-60 Frequency Range (Hz) Wi Series ITC/HS 2cc 1.6 1.6 Reference Test Frequency (khz) OSPL FOG HFA Frequencies (khz) 28 36 32 41 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Attack and Release Time () Test Mode Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) 0 00 OSPL OSPL (gray) and Full-On Gain (black) curves for the Wi Series HS at /. Wi Series ITC/HS 2cc FOG 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity 89 94 HFA SPLITS (ANSI) (db SPL) 71 82 MASL (IEC) (db SPL) 1.22 1.22 1.22 1.22 Battery Current (ma) 1.15 1.15 1.15 1.15 Idle Current (ma) Estimated Battery Life for 16-Hour Day 0 00 OSPL (gray) and Full-On Gain (black) curves for the Wi Series HS at 115/. 8-9* 8-9* 8-9* 8-9* 312 Zinc Air (days) * Results for wireless products will vary based on wireless usage. 19
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) ITC IN-THE-CANAL Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery SIZE: 312 DATA 0 ITC / ITC 115/ Measurement 2cc 2cc 2 0 1K 2K 4K 8K Peak OSPL (db SPL) 119 115 124 HFA OSPL (db SPL) 5 9 RTF OSPL (db SPL) 111 116 Peak Gain (db) 49 58 Wi Series ITC fitting range. HFA Full-On Gain (db) 36 46 RTF Full-On Gain (db) 43 53 Wi Series ITC/HS 2cc Frequency Range (Hz) - 00-70 - 60-60 OSPL FOG Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 28 36 32 41 Harmonic Distortion 0 00 OSPL (gray) and Full-On Gain (black) curves for the Wi Series ITC at /. OSPL Wi Series ITC/HS 2cc FOG Attack and Release Time () Test Mode 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Attack Time (ms) Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 89 94 MASL (IEC) (db SPL) 71 82 0 00 OSPL (gray) and Full-On Gain (black) curves for the Wi Series ITC at 115/. Battery Current (ma) 1.22 1.22 1.22 1.22 Idle Current (ma) 1.15 1.15 1.15 1.15 Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 8-9* 8-9* 8-9* 8-9* * Results for wireless products will vary based on wireless usage.
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery SIZE: CIC COMPLETELY-IN-CANAL DATA CIC / CIC 115/ 0 2cc 2cc Measurement 119 115 124 Peak OSPL (db SPL) 4 HFA OSPL (db SPL) 115 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 49 58 Peak Gain (db) 35 46 HFA Full-On Gain (db) Wi Series CIC fitting range. 43 54 RTF Full-On Gain (db) - 70-70 - 70-70 Frequency Range (Hz) Wi Series CIC 2cc 1.6 1.6 Reference Test Frequency (khz) OSPL FOG HFA Frequencies (khz) 28 35 32 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Attack and Release Time () Test Mode Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) 0 00 OSPL OSPL (gray) and Full-On Gain (black) curves for the Wi Series CIC at /. FOG Wi Series CIC 2cc 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) MASL (IEC) (db SPL) 1.17 1.17 1.17 1.17 Battery Current (ma) 1.12 1.12 1.13 1.13 Idle Current (ma) Estimated Battery Life for 16-Hour Day 0 00 OSPL (gray) and Full-On Gain (black) curves for the Wi Series CIC at 115/. 4-6* 4-6* 4-6* 4-6* Zinc Air (days) * Results for wireless products will vary based on wireless usage. 21
22 SMALL NEW IS THE POWERFUL
3 Series If you want to fit something small that will deliver big benefits to you and your patients, then you want to fit Xino, the smallest, most fully loaded RIC we ve ever designed. And with three different Xinos to choose from wireless, non-wireless and now with our patent-pending Multiflex Tinnitus Technology there s one perfect for every patient. MINI RICS Wi SERIES XINO Xino Feature Chart 24 Xino micro RIC 312 Summary 26 Xino RIC Summary 27 micro RIC 28 micro RIC AP 29 RIC RIC AP 31 Xino Tinnitus Feature Chart 32 Xino Tinnitus Summary 33 DEEP CANAL INSTRUMENTS SOUNDLENS TOUR/IGNITE Xino Tinnitus RIC 34 Xino Tinnitus RIC AP 35 SURFLINK Accessories 23
3 Series Sound Imaging Binaural Spatial Mapping VIBRANT Optimal high-resolution sound imaging with frequency shaping in all 16 channels and 16 bands Premium Ear-to-Ear Processing Wi SERIES W I R E L E S S Machine Noise Wind Directionality Synchronized User Controls Binaural Telephone Mode Volume Memory SurfLink Accessory Compatibility SurfLink Mobile SurfLink Programmer SurfLink Media SurfLink Remote XINO MINI RICS SOUNDLENS DEEP CANAL INSTRUMENTS XINO FEATURE CHART iq Boost PureWave Feedback Eliminator Acoustic Scene Analyzer Voice iq 2 Noise Reduction Strength AudioScapes Machine Noise Speech in Noise Wind Quiet Speech Noise Premium 16-channel environmental adaptation with 5 levels of personalization Maximum (db) AudioScape Adaptation Levels 5 Spectral iq TOUR/IGNITE SURFLINK Accessories SoundPoint Self Learning Swap Fit 3D Speech Mapping All Xino Models Include: Ergonomic Switch to Adjust Volume and Memory ISO Compression Strategy (Xino Wireless Only) SnapFit Receivers (Xino Wireless Only) InVision Directionality Automatic Telephone Solutions Live Speech Mapping Advanced Memories (Music, TV, Relax, T-Coil, Binaural Processing Off) T 2 On Demand Programming 24
ACTIVE High-resolution sound imaging with frequency shaping in 12 channels and 12 bands SOCIAL Frequency shaping in 8 channels and 8 bands Advanced Ear-to-Ear Processing Advanced 12-channel environmental adaptation with 3 levels of personalization Select 8-channel environmental adaptation with 2 levels of personalization Moderate (8dB) Light (6dB) 3 on/off In-Situ Audiometry Auto Path Verify Comfort Data Logging 4 Memories 25
XINO Micro RIC 312 Xino Wireless MICRO RIC 312 The newest member of our popular wireless lineup, Xino Wireless is a newly designed micro RIC 312 that delivers the features and freedom that our patented IRIS Technology enables including Binaural Spatial Mapping, no body-worn relay device, wire-free phone streaming, media streaming and programming, synchronized user controls and more. Incredibly small, wireless RIC 312 Loaded with Starkey s industry-leading performance features, including: o Binaural Spatial Mapping our ear-to-ear protocol that delivers a more natural 3-D like listening experience o Voice iq 2 our superior performing noise reduction and speech preservation system o Spectral iq the industry s most intelligent way to enhance highfrequency audibility o PureWave Feedback Eliminator adds up to 28dB of added stable gain Flexible and powerful can fit up to gain Compatible with our innovative SurfLink accessories, including SurfLink Mobile Color Guide Standard Colors Champagne Sterling Bronze Slate Espresso Black Bright Colors Blue Ice Fuchsia Fabulous Blue Pacific Red Hot Pink Pixie Purple Pop 26
XINO RIC Xino RIC Xino might be tiny, but it packs a punch when it comes to performance, style and one-of-a-kind features found in a RIC with a A battery. Designed to be nearly invisible; one of Starkey s ever-increasing options that is virtually unseen when worn by the patient Fits nearly all types of hearing loss, with receivers ranging from db to db Absolute Power (AP) receivers Is the only A RIC with a configurable user control (volume or memory), telecoil and locking battery door Includes all of Starkey s leading performance features Features HydraShield 2, our proprietary nano-coating technology designed to repel wax, oils and moisture Builds off Starkey s award-winning design language that has earned multiple design, medical and consumer electronics honors Color Guide Standard Colors Champagne Sterling Bronze Slate Pearl Onyx Bright Colors Blue Ice Fuchsia Fabulous Blue Pacific Red Hot Pink Pixie Purple Pop 27
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) XINO micro RIC 312 RECEIVER-IN-CANAL Matrices: 115/, / Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA 0 2 0 1K 2K 4K 8K Measurement Gain Data Gain Data 2cc 2cc Peak OSPL (db SPL) 115 125 1 HFA OSPL (db SPL) 9 115 RTF OSPL (db SPL) 116 125 Xino Wireless RIC 312 (gray), and Xino Wireless RIC 312 (black). Peak Gain (db) 62 71 HFA Full-On Gain (db) 44 54 RTF Full-On Gain (db) 53 62 Wireless RIC312 115/ Stock Frequency Range (Hz) -70-70 - 70-70 OSPL 55 FOG 115 Reference Test Frequency (khz) 1.6 1.6 45 5 HFA Frequencies (khz) 35 25 15 95 85 75 Reference Test Gain (db) 32 41 38 Harmonic Distortion 0 00 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 OSPL (gray) and Full-On Gain (black) curves for the Xino Wireless RIC 312 at 115/. Wireless RIC312 / Stock Induction Coil Sensitivity Hz (%) <3 <3 <3 <3 HFA SPLITS (ANSI) (db SPL) OSPL FOG 1 MASL (IEC) (db SPL) Battery Current (ma) 1.7 1.7 2.0 2.0 0 00 Idle Current (ma) 1.3 1.3 1.4 1.4 Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 5-7* 5-7* 4-6* 4-6* OSPL (gray) and Full-On Gain (black) curves for the Xino Wireless RIC 312 at /. * Results for wireless products will vary based on wireless usage. 28
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) Matrices: 123/, 1/ Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 XINO micro RIC 312 AP RECEIVER-IN-CANAL ABSOLUTE POWER DATA Gain Data Gain Data 2cc 2cc Measurement 123 131 1 137 Peak OSPL (db SPL) 116 125 HFA OSPL (db SPL) 124 132 RTF OSPL (db SPL) 0 2 0 1K 2K 4K 8K 67 78 Peak Gain (db) 54 64 HFA Full-On Gain (db) 61 72 RTF Full-On Gain (db) - - -50-50 Frequency Range (Hz) 1.6 1.6 Reference Test Frequency (khz) Xino Wireless RIC 312 AP (gray), Xino Wireless RIC 312 AP (black) fitting ranges. OSPL Wireless RIC312 123/ AP FOG 1 HFA Frequencies (khz) 39 51 48 61 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 0 00 OSPL (gray) and Full-On Gain (black) curves for the Xino Wireless RIC 312 AP at 123/. Wireless RIC312 1/ AP MASL (IEC) (db SPL) OSPL FOG 1 1.4 1.4 1.7 1.7 Battery Current (ma) 1.3 1.3 1.4 1.4 Idle Current (ma) 1 Estimated Battery Life for 16-Hour Day 6-8* 6-8* 4-6* 4-6* 312 Zinc Air (days) 0 00 OSPL (gray) and Full-On Gain (black) curves for the Xino Wireless RIC 312 AP at 1/. * Results for wireless products will vary based on wireless usage. 29
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) XINO RECEIVER-IN-CANAL Matrices: /, 115/, / Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: DATA 0 2 0 1K 2K 4K 8K Measurement Gain Data Gain Data Gain Data 2cc 2cc 2cc Peak OSPL (db SPL) 122 115 126 1 HFA OSPL (db SPL) 2 8 112 RTF OSPL (db SPL) 116 118 Xino (gray), Xino (dark gray), Xino (black) fitting ranges. Xino RIC 2cc Peak Gain (db) 51 61 HFA Full-On Gain (db) 31 44 51 OSPL FOG RTF Full-On Gain (db) 39 51 57 Frequency Range (Hz) - 70-70 - 70-70 - -70 0 00 Reference Test Frequency (khz) HFA Frequencies (khz) 1.6 1.6 1.6 Reference Test Gain (db) 25 32 31 41 35 43 OSPL (gray) and Full-On Gain (black) curves for the Xino at /. Xino RIC 2cc Harmonic Distortion 0 Hz (%) <3 <3 <3 <3 <3 <3 OSPL FOG 0 Hz (%) <3 <3 <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 <3 <3 Attack and Release Time () Test Mode Attack Time (ms) 15 15 15 15 15 15 0 00 Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 5-1 5-2 OSPL (gray) and Full-On Gain (black) curves for the Xino at 115/. Wireless RIC312 / Stock OSPL FOG 1 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 5-1 5-2 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 84 88 95 MASL (IEC) (db SPL) 81 89 Battery Current (ma) 1.2 1.2 1.4 1.3 1.6 1.4 Idle Current (ma) 1.1 1.1 1.2 1.2 1.2 1.2 0 00 Estimated Battery Life for 16-Hour Day Zinc Air (days) 5-8 5-8 5-8 5-8 4-6 4-6 OSPL (gray) and Full-On Gain (black) curves for the Xino at /.
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) Matrices: 123/, 1/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: XINO AP RECEIVER-IN-CANAL ABSOLUTE POWER DATA Gain Data Gain Data 2cc 2cc Measurement 123 1 1 137 Peak OSPL (db SPL) 115 124 HFA OSPL (db SPL) 127 135 RTF OSPL (db SPL) 0 2 0 1K 2K 4K 8K 69 79 Peak Gain (db) 52 65 HFA Full-On Gain (db) 63 75 RTF Full-On Gain (db) - - - 00-40 Frequency Range (Hz) Xino AP (gray), Xino AP (black) fitting ranges. Xino RIC AP 2cc 1.6 1.6 Reference Test Frequency (khz) OSPL FOG 1 HFA Frequencies (khz) 38 52 47 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Attack and Release Time () Test Mode 0 00 OSPL (gray) and Full-On Gain (black) curves for the Xino AP at 123/. 15 15 15 15 Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) OSPL FOG 1 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 1 Induction Coil Sensitivity 98 5 HFA SPLITS (ANSI) (db SPL) 95 8 MASL (IEC) (db SPL) 1.2 1.2 1.6 1.4 Battery Current (ma) 1.1 1.1 1.2 1.2 Idle Current (ma) Estimated Battery Life for 16-Hour Day 0 00 OSPL (gray) and Full-On Gain (black) curves for the Xino AP at 1/. 5-8 5-8 4-6 4-6 Zinc Air (days) 31
FEATURE CHART Sound Imaging Optimal high-resolution sound imaging with frequency shaping in all 12 channels and 12 bands PureWave Feedback Eliminator Acoustic Scene Analyzer Premium 12-channel environmental adaptation with 3 levels of personalization Voice iq 2 Noise Reduction Strength Moderate (8dB) AudioScapes Machine Noise Speech in Noise Wind Quiet Speech Noise AudioScape Adaptation Levels 3 SoundPoint Self Learning Swap Fit 3D Speech Mapping 32
XINO Tinnitus Xino Tinnitus Xino Tinnitus is a new solution designed to help provide relief to the million Americans affected by tinnitus. Using our patent-pending Multiflex Tinnitus Technology, Xino Tinnitus enables hearing professionals to customize a sound stimulus designed to relieve each patient s unique symptoms, making it the most flexible and personalized way to treat tinnitus. Tinnitus Therapy + Hearing Aid = Two Devices in One o Configured memories (tinnitus, tinnitus + hearing aid, hearing aid) Flexible adjustments in 16 bands o Amplification operates independently of tinnitus stimulus Ability to adjust modulation rate of stimulus o Stimulus is a white noise, amplitude and frequency modulation is available and is configurable via 12 bands Compatible with both tinnitus retraining therapy and masking protocols Personalized adjustments during fitting made by patient using SoundPoint Tinnitus Flexible device-level control Nearly invisible device RIC Color Guide Standard Colors Champagne Sterling Bronze Slate Pearl Onyx 33
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) XINO TINNITUS RECEIVER-IN-CANAL MATRICES: /, 115/, / Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: DATA Xino Tinnitus (gray), Xino Tinnitus (dark gray), Xino Tinnitus (black) fitting ranges. Xino RIC 2cc 0 2 0 1K 2K 4K 8K OSPL FOG Measurement Gain Data Gain Data Gain Data 2cc 2cc 2cc Peak OSPL (db SPL) 122 115 126 1 HFA OSPL (db SPL) 2 8 112 RTF OSPL (db SPL) 116 118 Peak Gain (db) 51 61 HFA Full-On Gain (db) 31 44 51 RTF Full-On Gain (db) 39 51 57 Frequency Range (Hz) - 70-70 - 70-70 - - 70 0 00 OSPL (gray) and Full-On Gain (black) curves for the Xino Tinnitus at /. OSPL FOG Xino RIC 2cc Reference Test Frequency (khz) HFA Frequencies (khz) 1.6 1.6 1.6 Reference Test Gain (db) 25 32 31 41 35 43 Harmonic Distortion 0 Hz (%) <3 <3 <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 <3 <3 Attack and Release Time () Test Mode Attack Time (ms) 15 15 15 15 15 15 Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 5-1 5-2 0 00 OSPL (gray) and Full-On Gain (black) curves for the Xino Tinnitus at 115/. Wireless RIC312 / Stock OSPL FOG 1 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 84 88 95 MASL (IEC) (db SPL) 72 81 89 Battery Current (ma) 1.2 1.2 1.4 1.3 1.6 1.4 Idle Current (ma) 1.1 1.1 1.2 1.2 1.2 1.2 Estimated Battery Life for 16-Hour Day Zinc Air (days) 5-8 5-6 5-8 5-8 4-6 4-6 Tinnitus Therapy Stimulus 34 0 00 OSPL (gray) and Full-On Gain (black) curves for the Xino Tinnitus at /. Max RMS Output (db SPL) 87 87 87 Weighted RMS Output Level (db SPL) 87 87 87 Max 1/3 Octave Output (db SPL) 87 87 87
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) MATRICES: 123/, 1/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: XINO TINNITUS AP RECEIVER-IN-CANAL RECEIVER-IN-CANAL ABSOLUTE POWER ABSOLUTE POWER DATA Gain Data Gain Data 2cc 2cc Measurement 123 1 1 137 Peak OSPL (db SPL) 115 124 HFA OSPL (db SPL) 127 135 RTF OSPL (db SPL) 69 Peak Gain (db) 52 65 HFA Full-On Gain (db) 63 75 RTF Full-On Gain (db) - - - 00-40 Frequency Range (Hz) 1.6 1.6 Reference Test Frequency (khz) HFA Frequencies (khz) 38 52 47 Reference Test Gain (db) OSPL FOG 0 2 0 1K 2K 4K 8K Xino Tinnitus AP (gray), Xino Tinnitus AP (black) fitting ranges. Xino RIC AP 2cc 1 Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) 0 00 Attack and Release Time () Test Mode 15 15 15 15 Attack Time (ms) OSPL (gray) and Full-On Gain (black) curves for the Xino Tinnitus AP at 123/. 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity 98 5 HFA SPLITS (ANSI) (db SPL) OSPL FOG 1 1 95 8 MASL (IEC) (db SPL) 1.2 1.2 1.6 1.4 Battery Current (ma) 1.1 1.1 1.2 1.2 Idle Current (ma) Estimated Battery Life for 16-Hour Day 5-8 5-8 4-6 4-6 Zinc Air (days) Tinnitus Therapy Stimulus 87 87 Max RMS Output (db SPL) 0 00 OSPL (gray) and Full-On Gain (black) curves for the Xino Tinnitus AP at 1/. 87 87 Weighted RMS Output Level (db SPL) 87 87 Max 1/3 Octave Output (db SPL) 35
THE ORIGINAL IIC 36
3 Series Imitated but never duplicated, our SoundLens isn t just the world s first ever custom-fit invisible-in-the-canal (IIC) hearing aid it s also the most popular. Invisible solutions are a proven draw for new patients. Now available in three technology levels, SoundLens gives you and your patients more options to choose from than ever before. When it comes to invisible custom hearing aids, Soundlens is the benchmark by which all other IICs are judged. Wi SERIES XINO MINI RICS SoundLens Feature Summary 38 SoundLens 39 DEEP CANAL INSTRUMENTS SOUNDLENS TOUR/IGNITE SURFLINK Accessories 37
3 Series Wi SERIES XINO MINI RICS SOUNDLENS Feature Summary Voice iq 2 nearly doubles the noise reduction capability of our leading noise reduction and speech preservation system while still maintaining speech. Voice iq 2 : Instantly applies variable noise adaptation in all channels between each pause Provides up to db of noise reduction Unlike competing technologies that apply frequency compression broadly, our frequency audibility technology, Spectral iq, is designed to enhance real-time audibility by intelligently identifying high-frequency speech cues, then replicating them in lower frequencies. This allows SoundLens to maintain important frequency relationships, retaining the sound quality that comes from harmonic distribution, while providing audibility for high-frequency speech cues for patients that may have previously been considered unaidable. SoundLens wouldn t be a Starkey product without our PureWave Feedback Eliminator. This leading technology ensures wide fitting ranges and a fast response to more complex feedback. SOUNDLENS DEEP CANAL INSTRUMENTS Voice Indicators alert your patients to the status of their hearing aid, low battery, memory and telephone modes in their choice of male or female voices in a wide variety of languages. Our Swap Fit fitting function allows you to transfer patient settings from their current Starkey product to a new one enabling more time for fine-tuning and counseling. TOUR/IGNITE SURFLINK Accessories 38
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) Matrices: 111/35, 111/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: IIC INVISIBLE-IN-CANAL DATA 35 Gain Data Gain Data 2cc 2cc Measurement 111 111 Peak OSPL (db SPL) 6 4 HFA OSPL (db SPL) 114 111 RTF OSPL (db SPL) 0 2 0 1K 2K 4K 8K 35 45 Peak Gain (db) 31 36 HFA Full-On Gain (db) 38 44 RTF Full-On Gain (db) 70 70 70 70 Frequency Range (Hz) IIC SoundLens IIC fitting range. 1.6 1.6 Reference Test Frequency (khz) HFA Frequencies (khz) OSPL FOG 29 31 27 36 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <28 <28 <28 <28 Equivalent Input Noise (db SPL) 0 00 OSPL (gray) and Full-On Gain (black) curves for the SoundLens IIC at a matrix of 111/35. IIC Attack and Release Time () Test Mode OSPL FOG 1 Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) MASL (IEC) (db SPL) 1.1 1.1 1.2 1.2 Battery Current (ma) 1.0 1.0 1.0 1.0 Idle Current (ma) 0 00 OSPL (gray) and Full-On Gain (black) curves for the SoundLens IIC at a matrix of 111/. Estimated Battery Life for 16-Hour Day 5-7 5-7 5-7 5-7 Zinc Air (days) 39
THE JOURNEY TO BETTER HEARING STARTS HERE
3 Series The exceptional quality and simple functionality that have made our wireless hearing aids so popular with patients and professionals is now available in an entry-level line. Wi SERIES A proven solution for those seeking value and performance, our Tour and Ignite family of products lets you bring the benefits of wireless hearing aids to virtually all your patients. XINO MINI RICS Tour RIC 312 42 Tour RIC 312 AP 43 Tour mini BTE 312 44 Tour BTE 13 45 DEEP CANAL INSTRUMENTS SOUNDLENS Ignite ITE 46 Ignite HS 47 Ignite ITC 48 Ignite CIC 49 TOUR/IGNITE SURFLINK Accessories 41
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) 3 Series RIC 312 RECEIVER-IN-CANAL Matrices: 115/, / Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 Wi SERIES 0 Measurement Gain Data Gain Data 2cc DATA 2cc Peak OSPL (db SPL) 115 125 1 HFA OSPL (db SPL) 9 115 RTF OSPL (db SPL) 116 125 XINO MINI RICS 2 0 1K 2K 4K 8K Tour RIC 312 (gray) and Tour RIC 312 (black). Peak Gain (db) 62 71 HFA Full-On Gain (db) 44 54 RTF Full-On Gain (db) 53 62 Frequency Range (Hz) -70-70 -70-70 SOUNDLENS DEEP CANAL INSTRUMENTS OSPL FOG 1 0 00 Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 32 41 38 Harmonic Distortion 0 Hz (%) <3 <3 <3 <3 TOUR/IGNITE OSPL (gray) and Full-On Gain (black) curves for the Tour RIC 312 at 115/. OSPL FOG 1 Induction Coil Sensitivity 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 HFA SPLITS (ANSI) (db SPL) 86 93 MASL (IEC) (db SPL) 91 Battery Current (ma) 1.7* 1.7* 2.0* 2.0* Idle Current (ma) 1.3* 1.3* 1.4* 1.4* SURFLINK Accessories 42 0 00 OSPL (gray) and Full-On Gain (black) curves for the Tour RIC 312 at /. Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 5-7* 5-7* 4-7* 4-7* * Results for wireless products will vary based on wireless usage.
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) Matrices: 123/, 1/ Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 RIC 312 AP RECEIVER-IN-CANAL ABSOLUTE POWER DATA Gain Data Gain Data 2cc 2cc Measurement 123 131 1 137 Peak OSPL (db SPL) 116 125 HFA OSPL (db SPL) 126 136 RTF OSPL (db SPL) 67 78 Peak Gain (db) 0 2 0 1K 2K 4K 8K 53 64 HFA Full-On Gain (db) 64 75 RTF Full-On Gain (db) Tour RIC 312 AP (gray), Tour RIC 312 AP (black) fitting ranges. - - 50-50 - 4 Frequency Range (Hz) OSPL FOG 1.6 1.6 Reference Test Frequency (khz) 1 HFA Frequencies (khz) 39 51 48 61 Reference Test Gain (db) Harmonic Distortion 0 00 <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) OSPL (gray) and Full-On Gain (black) curves for the Tour RIC 312 AP at 123/. <3 <3 <3 <3 Hz (%) Induction Coil Sensitivity OSPL FOG 1 95 2 HFA SPLITS (ANSI) (db SPL) 1 93 4 MASL (IEC) (db SPL) 1.2* 1.2* 1.4* 1.4* Battery Current (ma) 1.1* 1.1* 1.2* 1.2* Idle Current (ma) 0 00 Estimated Battery Life for 16-Hour Day 6-8* 6-8* 4-6* 4-6* 312 Zinc Air (days) OSPL (gray) and Full-On Gain (black) curves for the Tour RIC 312 AP at 1/. * Results for wireless products will vary based on wireless usage. 43
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) mini BTE 312 BEHIND-THE-EAR Matrix: 126/65 Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA Earhook Thin Tube (Size 3+, Occluded) 0 2 0 1K 2K 4K 8K Measurement 2cc 2cc Peak OSPL (db SPL) 126 131 124 HFA OSPL (db SPL) 118 8 RTF OSPL (db SPL) 1 112 Peak Gain (db) 65 64 68 Tour mini BTE 312 fitting range. HFA Full-On Gain (db) 52 RTF Full-On Gain (db) 69 57 Frequency Range (Hz) - 70-70 - 70-70 OSPL FOG 85 75 135 125 Reference Test Frequency (khz) 1.6 1.6 65 55 115 5 HFA Frequencies (khz) 45 95 35 25 85 75 Reference Test Gain (db) 41 53 31 37 15 65 0 00 OSPL (gray) and Full-On Gain (black) curves for the Tour mini BTE 312 with Earhook. Harmonic Distortion 0 Hz (%) <5 <5 <2 <2 0 Hz (%) <3 <3 <1 <1 Hz (%) <3 <3 <2 <2 OSPL 85 FOG 1 Induction Coil Sensitivity 75 HFA SPLITS (ANSI) (db SPL) 97 87 65 55 MASL (IEC) (db SPL) 92 86 45 35 Battery Current (ma) 1.3* 1.3* 1.3* 1.3* 25 15 0 00 OSPL (gray) and Full-On Gain (black) curves for the Tour mini BTE 312 with Thin Tube. Idle Current (ma) 1.2* 1.2* 1.2* 1.2* Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 9-11* 9-11* 9-11* 9-11* * Results for wireless products will vary based on wireless usage. 44
FOG OSPL (db) (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) MATRIX: 126/65 Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 13 BTE 13 BEHIND-THE-EAR DATA Earhook Thin Tube (Size 3+, Occluded) 2cc 2cc Measurement 126 131 121 124 Peak OSPL (db SPL) 119 8 HFA OSPL (db SPL) 1 112 RTF OSPL (db SPL) 65 63 68 Peak Gain (db) 59 52 HFA Full-On Gain (db) 57 RTF Full-On Gain (db) 0 2 0 1K 2K 4K 8K Tour BTE 13 fitting range. -70-70 -70-70 Frequency Range (Hz) Wireless BTE 13 126/65 Earhook OSPL FOG 1.6 1.6 Reference Test Frequency (khz) 85 75 135 125 1.0,1.6, 1.0,1.6, HFA Frequencies (khz) 65 55 115 5 42 55 31 37 Reference Test Gain (db) 45 35 25 95 85 75 Harmonic Distortion 15 0 00 65 <5 <4 <2 <2 0 Hz (%) <3 <4 <1 <1 0 Hz (%) <3 <3 <2 <2 Hz (%) Induction Coil Sensitivity 2 87 HFA SPLITS (ANSI) (db SPL) OSPL (gray) and Full-On Gain (black) curves for the Tour BTE 13 with Earhook. 85 75 OSPL Wireless BTE13 121/63 Thintube FOG 1 86 MASL (IEC) (db SPL) 65 55 1.7* 1.7* 1.7* 1.7* Battery Current (ma) 45 35 1.3* 1.3* 1.3* 1.3* Idle Current (ma) 25 15 0 00 Estimated Battery Life for 16-Hour Day 9-11* 9-11* 9-11* 9-11* 13 Zinc Air (days) OSPL (gray) and Full-On Gain (black) curves for the Tour BTE 13 with Thin Tube. * Results for wireless products will vary based on wireless usage. 45
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) ITE IN-THE-EAR Matrices: 115/, 123/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: 13 DATA 0 2 0 1K 2K 4K 8K Measurement ITE 115/ ITE 123/ 2cc 2cc Peak OSPL (db SPL) 115 124 123 1 HFA OSPL (db SPL) 116 RTF OSPL (db SPL) 116 128 Peak Gain (db) 58 68 Ignite ITE fitting range. HFA Full-On Gain (db) 46 53 RTF Full-On Gain (db) 54 66 Wi Series ITE 2cc Frequency Range (Hz) - 60-00 - 00-5 OSPL FOG Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 33 41 39 53 Harmonic Distortion 0 00 OSPL (gray) and Full-On Gain (black) curves for the Ignite ITE at 115/. OSPL FOG X Series ITE 2cc 1 Attack and Release Time () Test Mode 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Attack Time (ms) Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 95 1 MASL (IEC) (db SPL) 83 95 0 00 OSPL (gray) and Full-On Gain (black) curves for the Ignite ITE at 123/. Battery Current (ma) 1.22 1.22 1.22 1.22 Idle Current (ma) 1.14 1.15 1.13 1.13 Estimated Battery Life for 16-Hour Day 13 Zinc Air (days) 12-16* 12-16* 12-16* 12-16* * Results for wireless products will vary based on wireless usage. 46
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 HS HALF-SHELL DATA HS / HS 115/ 0 2cc 2cc Measurement 119 115 124 Peak OSPL (db SPL) 5 9 HFA OSPL (db SPL) 111 116 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 49 58 Peak Gain (db) 36 46 HFA Full-On Gain (db) Ignite HS fitting range. 43 53 RTF Full-On Gain (db) - 00-70 - 60-60 Frequency Range (Hz) Wi Series ITC/HS 2cc 1.6 1.6 Reference Test Frequency (khz) OSPL FOG HFA Frequencies (khz) 28 36 32 41 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Attack and Release Time () Test Mode Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) 0 00 OSPL OSPL (gray) and Full-On Gain (black) curves for the Ignite HS at /. Wi Series ITC/HS 2cc FOG 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity 89 94 HFA SPLITS (ANSI) (db SPL) 71 82 MASL (IEC) (db SPL) 1.22 1.22 1.22 1.22 Battery Current (ma) 1.15 1.15 1.15 1.15 Idle Current (ma) Estimated Battery Life for 16-Hour Day 0 00 OSPL (gray) and Full-On Gain (black) curves for the Ignite HS at 115/. 8-9* 8-9* 8-9* 8-9* 312 Zinc Air (days) * Results for wireless products will vary based on wireless usage. 47
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) ITC IN-THE-CANAL Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA 0 ITC / ITC 115/ Measurement 2cc 2cc 2 0 1K 2K 4K 8K Peak OSPL (db SPL) 119 115 124 HFA OSPL (db SPL) 5 9 RTF OSPL (db SPL) 111 116 Peak Gain (db) 49 58 Ignite ITC fitting range. HFA Full-On Gain (db) 36 46 RTF Full-On Gain (db) 43 53 Wi Series ITC/HS 2cc Frequency Range (Hz) - 00-70 - 60-60 OSPL FOG Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 28 36 32 41 Harmonic Distortion 0 00 OSPL (gray) and Full-On Gain (black) curves for the Ignite ITC at /. OSPL Wi Series ITC/HS 2cc FOG Attack and Release Time () Test Mode 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Attack Time (ms) Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 89 94 MASL (IEC) (db SPL) 71 82 0 00 OSPL (gray) and Full-On Gain (black) curves for the Ignite ITC at 115/. Battery Current (ma) 1.22 1.22 1.22 1.22 Idle Current (ma) 1.15 1.15 1.15 1.15 Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 8-9* 8-9* 8-9* 8-9* * Results for wireless products will vary based on wireless usage. 48
FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: CIC COMPLETELY-IN-CANAL DATA CIC / CIC 115/ 0 2cc 2cc Measurement 119 115 124 Peak OSPL (db SPL) 4 HFA OSPL (db SPL) 115 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 49 58 Peak Gain (db) 35 46 HFA Full-On Gain (db) Ignite CIC fitting range. 43 54 RTF Full-On Gain (db) - 70-70 - 70-70 Frequency Range (Hz) Wi Series CIC 2cc 1.6 1.6 Reference Test Frequency (khz) OSPL FOG HFA Frequencies (khz) 28 35 32 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Attack and Release Time () Test Mode Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) 0 00 OSPL OSPL (gray) and Full-On Gain (black) curves for the Ignite CIC at /. FOG Wi Series CIC 2cc 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) MASL (IEC) (db SPL) 1.17 1.17 1.17 1.17 Battery Current (ma) 1.12 1.12 1.13 1.13 Idle Current (ma) Estimated Battery Life for 16-Hour Day 0 00 OSPL (gray) and Full-On Gain (black) curves for the Ignite CIC at 115/. 4-6* 4-6* 4-6* 4-6* Zinc Air (days) * Results for wireless products will vary based on wireless usage. 49
Carefree connectivity IS HERE
3 Series Combined with any of our wireless hearing aids, Starkey s innovative and popular lineup of SurfLink accessories gives your patients unprecedented control, convenience and freedom. Wi SERIES SurfLink Features 52 XINO MINI RICS SOUNDLENS DEEP CANAL INSTRUMENTS TOUR/IGNITE SURFLINK Accessories 51
3 Series Wi SERIES Cell Phone Noisy Places Lectures LIFE WITHOUT LIMITATIONS XINO MINI RICS Meetings Television Music SOUNDLENS DEEP CANAL INSTRUMENTS SURFLINK MOBILE Hands-free phone conversations (and more) are here with SurfLink Mobile. This versatile device is the industry s most unique cell phone solution, assistive listening device, media streamer, and hearing aid remote all rolled into one. TOUR/IGNITE SURFLINK Accessories Using our revolutionary JustTalk mode, SurfLink Mobile enables hands-free cell phone conversations by turning our wireless hearing aids into the phone microphone and receiver: o Microphone The wearer s hearing aids pick up their voice and send it to the person they re talking to o Receiver SurfLink Mobile streams the voice on the other end of the phone directly to both of the wearer s hearing aids for binaural listening Directional microphone enhances one-onone conversations in noisy environments Omnidirectional capability is ideal for listening in meetings or group settings Wirelessly streams sound from TVs or MP3 players using Bluetooth or an audio connector cable Can also be used as a powerful ALD as well as a hearing aid remote 52
SURFLINK MEDIA SurfLink Media provides patients with the first set-and-forget media streaming solution. Simply plug a TV, radio or MP3 player into SurfLink Media and rich, stereo sound is streamed directly to any wireless hearing aids in range without pairing or body-worn relay devices. SurfLink Media: Streams stereo sound directly from media devices to the patient s hearing aids without pairing or body-worn relay devices Uses Intelligent Media Mobility to allow seamless room-to-room transitions between media devices Enables multiple people wearing wireless hearing aids to connect to a single device Eliminates audio delay and lip-sync issues* commonly found with other wireless systems Helps prevent patients and companions from fighting over the volume SURFLINK Programmer Our SurfLink Programmer, combined with IRIS Technology and Inspire fitting software, gives you the ultimate speed and flexibility in direct-to-hearing aid wireless programming with no relay device. Detects your patients wireless devices in seconds Features at least a -foot range Frees patients to move around during counseling and demonstrations Connects via standard USB cable Requires no additional hardware for the patient Is 4x faster than HiPro and nearly twice as fast as NOAHLink and nearcom SURFLINK Remote With the optional SurfLink Remote, patients can control memory and volume adjustments, mute their hearing instruments, or go in and out of streaming mode if they desire. *Latency is unnoticeable according to International Telecommunications Union standards 53
Measurement Conditions and Recommendations The data for Starkey hearing instruments are obtained and performance is expressed according to ANSI S3.22 (03), ANSI C63.19 (07), IEC 118-7 (05) and IEC 118-0 (1983) with Amendment 1 (1994-01). The Starkey proprietary Real Time Analyzer and the Starkey Automated Design Verification Test System (SADVTS) comprise the basic test equipment. Data may be subject to change with product refinement. Because of the adaptive signal processing capabilities of Starkey hearing instruments, the hearing instrument must be set to test mode to compare the actual performance of the hearing instrument with these specifications. Starkey hearing instruments may be set to test mode with Inspire by reading the hearing aid and selecting the Hearing Aid Test screen from the menu on the left side of the Inspire window, then selecting the Full on Gain button. *All trademarks or trade names are properties of their respective owners. 54
www.starkeypro.com Washington Avenue South Eden Prairie, MN 55344-3476 1.0.328.82 12 Starkey. All Rights Reserved. 85438-000 BKLT0335-00-EE-ST 11/12