Fire or Ignition Resistant? Building Materials & Vegetation



Similar documents
IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

Fire Testing of Recycled Materials for Building Applications

Landscaping with Ornamental Trees and Exterior Structure Features Using EcoSmart Fire Model

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

READY, SET, GO! YOUR PERSONAL WILDFIRE ACTION PLAN

Fire-Rated Glass and Glazing START

FireWise Construction: Site Design & Building Materials. Based on the 2009 International Wildland-Urban Interface Code

Your Defensible Space Slideshow

READY, SET, GO! Montana YOUR PERSONAL WILDLAND FIRE ACTION GUIDE

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

How To Make A House Safe

National Hazard and Risk Model (No-HARM) Wildfire

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

How To Test For Premer Retardant

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Preventing Ice Dams on Roofs

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

WOOD ROOF REPLACEMENT ORDINANCE: COMMUNITY MEETING QUESTIONS AND ANSWERS

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

Wood use in Type I and II (noncombustible) construction

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Fire Classification Rating Testing of Stand-Off Mounted Photovoltaic Modules and Systems

COMPARISON OF VARIOUS SINGLE PLY ROOF COVERS FOR FIRE RESISTANCE

EcoTouch Insulation with PureFiber Technology

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

FIRE AND SMOKE PROTECTION FEATURES

Building Code Clarifications - 7. Fire Resistance

Approval Standard for Plastic Suspended Ceiling Panels

Tremco Fire Protection Systems Group Technical Bulletin

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

furnishings flammability characteristics

ATI Evaluation Service A Division of Architectural Testing Certification Services

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

WHITE PAPER Fire & safety performance standards

Planning for Bushfire Risk Mitigation General Code

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

FIRE-RESISTANCE-RATED CONSTRUCTION

Excerpts from the Canadian National Building Code (NBC)

Fiberglas, Exterior Wall Thermal Insulation

Gypsum Board Systems Manual

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

READY, SET, GO! YOUR PERSONAL WILDLAND FIRE ACTION GUIDE

Approval Standard for Fume Exhaust Ducts or Fume and Smoke Exhaust Ducts

Chapter 6 ROOF-CEILING SYSTEMS

The Florida Building Code

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Asphalt Shingle Application Requirements

FIRE-RESISTANCE-RATED CONSTRUCTION

ELIGIBLE REPAIR PROJECT PARAMETERS

A CONSEQUENCE OF THE FIRE EXCLUSION PARADIGM

Lessons Learned from Waldo Canyon FIRE ADAPTED COMMUNITIES MITIGATION ASSESSMENT TEAM FINDINGS

Fire Damage. To Help Prevent. a Guide

Annex of the certificate (Page 1/6) Accreditation Scope

GYPSUM AREA SEPARATION FIREWALLS GA

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

2014 British Columbia Building Code Changes

FIRE AND SMOKE PROTECTION FEATURES

Development Services City of Lawrence, KS

DURATION STORM. TruDefinition. TruDefinition Duration STORM Shingles are a component of the Owens Corning Total Protection Roofing System.

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

General Fire Code Requirements Within Commercial Tenant Spaces

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

Pyroguard Wired Glass

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Chapte r 17. Fire Safety. Contents. Fire Safety Design and Evaluation. Robert H. White and Mark A. Dietenberger

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

Detached accessory structures that contain no conditioned floor area are exempt.

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Gas Meter Clearances and Service Installation Requirements

Transcription:

Fire or Ignition Resistant? Building Materials & Vegetation Steve Quarles, IBHS & Pat Durland, Stone Creek Fire, LLC 2011 Backyards & Beyond Wildland Fire Education Conference Denver, Colorado October 27, 2011

Reducing the vulnerability of buildings to wildfires new construction retrofit to existing

Terms describing the combustibility of materials - Noncombustible Nonflammable Combustible Are we able to distinguish performance between different combustible materials? Ignition-resistant material (IR material versus IR construction?) Fire-resistant (assembly, typically with some combustible materials) Heat release rate (HRR) Time to ignition / penetration / other observation

Building Materials and Components Roof & Edge Eave & Vents Windows Decks & Other Attachments Siding

Fire Testing Equipment Big things, sort of big things, and small things

Setchkin Furnace specified in standard procedure used to determine if a material can be considered noncombustible. 750 C (1380 F) inside the furnace sample

Combustible Materials Flame Spread Rating (Class A, B, C) Heat Release Rate

Steiner Tunnel, used in horizontal flame spread tests Test material above the flame Photo courtesy of Bill Hendricks (photo taken at Southwest Research, San Antonio, TX)

Inside of tunnel Photo courtesy of Bill Hendricks (photo taken at Southwest Research, San Antonio, TX)

Steiner Tunnel horizontal flame spread tests Class A, B, C flame spread ratings ignition resistant material rating (California Building Code, NFPA, ICC) ignition resistant construction (California Building Code, Chapter 7A)

Exhaust hood measure amount of oxygen consumed during combustion. Calculate Heat Release Rate (HHR). (Photo taken at Western Fire Center, Kelso, WA)

Cone Calorimeter Photos taken at USDA FS Forest Products Laboratory, Madison, WI

Deck testing at the University of California Fire Test Laboratory, 2001. Development of criteria used in CA SFM Std. 12-7A-4. This test was conducted under a collection system and the HRR was evaluated. Peak Heat Release Rate (HRR) cannot exceed 25 kw / ft 2. The HRR during this test exceeded this amount, so this deck material would not comply with Chapter 7A requirements.

Fire-resistance ratings Nominal One-hour construction through use of Type X gypsum board in the wall assembly. Photo courtesy of Richard Avelar & Associates, Oakland, CA

Vertical burner largely radiant exposure One of 27 natural gas burners Time-temperature curve used during an ASTM E- 119 fire test. Photo taken at Western Fire Center, Kelso, WA

Vertical (or horizontal) Furnace X minute / hour (nominal) ratings - 20 minute rating [door, window] - 1-hour, 2-hour [wall, floor] Floor furnace Photo taken at Western Fire Center, Kelso, WA

Test apparatus for roof tests Roof deck and covering Air flow specified at 12 mph 1) flame penetration 2) flame spread 3) ember generation

Brands used in standard roof tests. One of three components in determining Class A, B, or C fire rating for a roof covering. Untreated wood shake roof is unrated. B - 6 by 6 C Class A 12 by 12

Igniting Class A brand

Fire rating for roof coverings Class A, B, & C Burning [12 x 12 ] Class A brand placed on roof covering. Flame penetrated through to the underside of the roof sheathing, into what would be the attic.

Roofing Stand-alone By assembly

Roll roofing can be sold generically, but if intended for use in a fire rated assembly, look for rating.

With assembly ratings, it is important to install the way it was tested. Read the directions & follow them. Consequences can be more critical than a parking ticket. Parked car!

Complex roof designs Intersection of roof-to-wall. Collection point for debris & embers. If debris is ignited by embers, flame contact exposure to shingle siding more vulnerable than Class A roof.

Openings at edge of roof and ridge must be plugged where necessary. Open areas allow entry of debris and embers the Class A roof covering can be by-passed.

The same basic apparatus is used for Wall, Window and Eave Tests [California SFM Standards 12-7A-1, 2, and 3]. These tests evaluate the fire resistance of a material & assembly. Window test Wall test Soffit test

CA SFM 12-7A-1. Testing at UC Fire Research Laboratory Unexposed side Exposed side 150 kw burner output, 10 minute exposure, plus 60 min observation Burn through at lap joints. As constructed, this wall doesn t pass

Plain bevel lap joints are vulnerable to flame penetration at the joint. Joint penetration - 1:15 min. More complicated lap joints, such as this shiplap joint, are more difficult to penetrate. Joint penetration - 21:20 min Source for figure: Dost and Botsai, 1990, Wood: Detailing for Performance

CA SFM 12-7A-1 (siding test) doesn t evaluate vertical flame spread that could result in flame impingement on windows and at eave. Fire demonstration, Southern California Penetration into stud cavity Flame spread up the wall

CA SFM 12-7A-2, window test. Testing has shown that the glass is more vulnerable than the frame. Glass failure Frame failure

Radiant exposure from neighboring house that was destroyed. Broken outer pane. Inner pane in tact. Window damaged. House survived.

Tempered glass more resistant to heat exposures than annealed glass. Prescriptive compliance to California Building Code Chapter 7A is inclusion of tempered pane in dual pane window. Tempered bug etched on glass

Eave / Horizontal Projection Test CA SFM 12-7A-3 Burn through at a joint in a combustible (wood) soffit. This view is from the perspective of the attic.

Expanded test for decking CA SFM 12-7A-4A Dropping flaming debris Heat Release Rate greater than 25 kw / ft 2 CA SFM 12-7A-4A, HRR already discussed. Other criteria included in 12-7A-4A standard includes selfextinguish within 40 min. and restriction on dropping burning debris

Class A brand / Roof test CA SFM 12-7A-4A also has burning brand test, using ASTM E-108 apparatus.

Ignition Resistant Material and Requirements for CA SFM 12-7A-4A SFM 12-7A-4 A - Part A. Under-deck flame impingement exposure. - Acceptance criteria: 1. HRR < 25 kw/ft2 2. Self-extinguish after 40 minutes 3. Cannot drop flaming debris 4. Cannot break under own load Part B. Brand test (top of deck) - Acceptance criteria: 1. Self-extinguish after 40 minutes 2. Cannot drop flaming debris 3. Cannot break under own load

Performance of decking Requirements for CA SFM 12-7A-4 Part A. Under-deck flame impingement exposure. - Acceptance criteria: 1. HRR < 25 kw/ft2 2. Self-extinguish after 40 minutes 3. Cannot drop flaming debris 4. Cannot break under own load Part B. Brand test (top of deck) - Acceptance criteria: 1. Self-extinguish after 40 minutes 2. Cannot drop flaming debris 3. Cannot break under own load Plus Flame Spread rating 10 minute ASTM E-84 Most combustible decking products that comply for use in California use this acceptance criteria.

Performance of decking Requirements for compliance in San Diego County Part A. Under-deck flame impingement exposure. - Acceptance criteria: 1. HRR < 25 kw/ft2 2. Self-extinguish Glowing allowed after 40 minutes 3. Cannot drop flaming debris 4. Cannot break under own load Part B. Brand test (top of deck) Use B brand instead of A brand. - Acceptance criteria: 1. Self-extinguish Glowing allowed after 40 minutes 2. Cannot drop flaming debris 3. Cannot break under own load

Performance related to decking (Fire demonstration in northern California) WPC, not 7A compliant Chapter 7A compliant (SFM 12-7A-4) 35 minutes after burning Class B brand placed on decks. WPC (wood plastic composite) Redwood Initial exposure to Class B brand placed on top surface. Noncombustible siding (gypsum wall board).

Noncombustible: yes or no, by test Combustible Materials: Heat Release Rate (HRR) Flame Spread Index Ignition Resistant Material yes or no, by test Fire resistance ratings Class A, B, C for roof Summary: You can use standard test data to discriminate performance between combustible materials. x minute or hour rating for wall, floor, or other component

Internet search for WUI Products Handbook http://osfm.fire.ca.gov/strucfireengineer/pdf/bml/wuiproducts.pdf

Thanks for your attention! Steve Quarles squarles@ibhs.org Cell: (813) 404-4942 www.disastersafety.org www.extension.org/surviving_wildfire Where building safety research leads to real-world solutions.

Vegetation Presentation by Pat Durland

Terms & Concepts Ignition resistant Fire resistant Highly flammable Volatile Low flammability Less flammable Lean, Clean & Green Firewise plants Vegetation

Landscape Assemblies in the Ignition Zone Large Flames (radiant heat) 100 away Surface Fire (flame contact) 30 away Ember Ignitions 30 away

Landscape Assemblies in the Ignition Zone Zone 1 (30 feet) Eliminate ignition hazards (available fuel)

Volatile Plants & Debris

The Undesired Results

Vegetation Flammable Characteristics Pyrophytes (fire plants) Active & Passive Oils, resins, waxes Excess litter Flammable Condition Dry tissue Low moisture content Unhealthy: stressed, aged, etc. Poorly maintained

Vegetation Flammable Characteristics Pyrophytes (fire plants) Active & Passive Oils, resins, waxes Excess litter Flammable Condition Dry tissue Low moisture content Unhealthy: stressed, aged, etc. Poorly maintained

It ain't what you don't know that gets you into trouble. It's what you know for sure that just ain't so. Mark Twain

Conflicts Plants described as highly flammable survive severe fire conditions? Lean?

Conflicts Plants described as highly flammable survive severe fire conditions? Plants described as low flammability, are volatile and burn intensely? Plant Lists Oleander Deciduous plants and trees

Different Outcomes to the same event WHY?

Observe what did NOT burn!

Pyrophyte Rehab

Pyrophyte Rehab

Everything should be made as simple as possible, but not simpler. Albert Einstein

Achieving a Firewise Landscape (by combining physical & social sciences) Understanding of how vegetation responses to fire Attractive/functional plants Effective messaging/marketing Explain catch phases Avoid generalizations A resident willing to ACT! Continued maintenance

Lean? Clean? Green?

Lean? Clean? Green?

Discussion

Thanks and Be Safe! Pat Durland www.stonecreekfire.com