Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Model #: SMART2200CRMXL

SURGE PROTECTIVE DEVICES

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

LOXONE 12 Channel Amplifier

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Uninterruptible Power Supply

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Power Supplies 3. SDN-P DIN Rail Series

Advantium 2 Plus Alarm

HP UPS R1500 Generation 3

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Arc Terminator Active Arc-Resistant Switchgear

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Provides one channel for Ethernet over existing

MCR1900 Media Converter 19-Slot Chassis

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

RY2 miniature industrial relays

Rack mounted telephone- and leased line modem for industrial applications

38 Series - Relay interface modules A

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ADM1TE 5/30A DIN rail single phase two wire energy meter

MAJORSINE Power Inverter

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

ED1259R5 Updated April 2011 For latest specs visit

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

38 Series - Relay interface modules A

LIEBERT VNSA Installation Sheet

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Provides one channel for Ethernet over existing

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Panduit 28 AWG Patch Cords Installation Guideline

Power Commander Power Distribution Units from Wiremold/Legrand offer

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

IP DSLAM IDL Quick Installation Guide

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Telephone- and leased line modem for industrial applications TD-36

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Redundancy Module QUINT-DIODE/40

ADACSNET USB Control Module

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

HM-W536 Install Guide

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

PNOZsigma - Base units

Color Mark Sensor with Red or Green LED E3S-VS

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

MasterINTERFACE 39 Series - Relay interface modules

Installation and Operation Guide PD4600 Series Converter Replacement

48 SERIES Relay interface modules 10 A

Product and functional description

MasterINTERFACE 39 Series - Relay interface modules

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

E-STOP relays, safety gate monitors

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

E-STOP relays, safety gate monitors

User s Manual AURORA 1.2K/2.2K

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

BC Pro UPS System Standby UPS System

SECTION LOW VOLTAGE LIGHTING CONTROLS

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Quick Connect. quick - simple - efficient.

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

E-STOP relays, safety gate monitors

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Water Leak Detection System

T7560A,B,C Digital Wall Module

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Specification Requirements DBL 700MX and 1000MX Series UPS

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Transcription:

Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion and surge protection for two or four SmartSensor Matrix or Advance units. Features Provides off-the-shelf support for your SmartSensor Matrix or Advance installation Includes terminal blocks, power supply, and surge suppression for a complete server rack assembly Comes preassembled on a 19-inch rack mount for easy installation into existing racks Color-coded terminal blocks match colors on SmartSensor 6-conductor cable for foolproof cable landing Converts AC power to DC Provides protection against lightning electrostatic surges on power inputs and on sensor cables Preassembled, prewired and tested for first-try functionality Insulation displacement terminal blocks for no-fuss cable termination Two models available, two-sensor rack and four-sensor rack WX-500-0211 1

Technical Specifications Assembly Components: Two-sensor rack 1 Click 202 2 A power supply 1 Click 210 0.5 A circuit breaker 2 Click 210-02 2 A circuit breakers 1 Click 222 system surge protector 1 Click 230 AC surge protector 1 T-bus 5-screw terminal block (left end) 4 T-bus connectors (power and communication) 1 T-bus connector (power only) 3 end brackets with labels 1 end bracket without label 4 terminal blocks for AC line input: spring cage to plug spring cage 10 AWG (2 grounded) 14 terminal blocks for cable termination: insulation displacement to plug insulation displacement (2 grounded) platform: traffic cabinet backplate 1 8-ft. power cord 1 8-ft. 14 awg ground cable 1 5-ft. black RJ-11 patch cable 2 5-ft. white RJ-11 patch cables Assembly Components: Four-sensor rack 1 Click 204 4 A power supply 5 Click 210-02 2 A circuit breakers 2 Click 222 system surge protectors 1 Click 230 AC surge protector 1 T-bus 5-screw terminal block (left end) 5 T-bus connectors (power and communication) 1 T-bus connector (power only) 5 end brackets with labels 2 end brackets without labels 4 terminal blocks for AC line input: spring cage to plug spring cage 10 AWG (2 grounded) 28 terminal blocks for cable termination: insulation displacement to plug insulation displacement (4 grounded) platform: traffic cabinet backplate 1 8-ft. power cord 1 8-ft. 14 awg ground cable 1 5-ft. black RJ-11 patch cable 4 5-ft. white RJ-11 patch cables Click 202/204 Specifications Weight: 0.55 lbs. (0.25 kg) / 1.1 lbs. (0.48 kg) dimensions: 4.5 in. 3.9 in. 1.7 in. (11.4 cm x 9.9 cm x 4.3 cm) / 4.2 in. x 3.9 in. x 2.7 in. (10.7 cm x 9.9 cm x 6.8 cm) Ambient operating temperature: -29 F to 140 F (-34 C to Ordering Information Intersection preassembled 19-inch rack Two-sensor rack SS-B02-0003 Intersection preassembled 19-inch rack Four-sensor rack SS-B02-0002 ACCESSORIES CLK-112/114 Click 112/114 rack cards Wavetronix 78 East 1700 South Provo, UT 84606 801.734.7200 sales@wavetronix.com www.wavetronix.com 60 C); between 140 F and 165 F (60 C and 74 C) derating Humidity: up to 95% RH Pluggable screw terminals for easy pre-wiring Click 202 power output at -29 F to 140 F (-34 C to 60 C): 2 A Click 204 power output at -29 F to 140 F (-34 C to 60 C): 4 A At temperatures between 140 F to 165 F (60 C and 74 C), output will decrease at a rate of 2.5% per degree Celsius temperature increase input: 100 240 VAC at 45 65 Hz Surge Protection Complies with the applicable standards stated in the IEC 61000-4-5 Standard for AC input power lines Efficiency Efficiency in converting AC input to DC: 80% or greater UL Listed Listed with UL under UL 508; complies with all applicable UL 508 standards. NEMA TS2-1998 Click 202 complies with the applicable standards stated in the NEMA TS2-1998 Standard 2 www.wavetronix.com

Test results available for each of the following for Click 202: shock pulses of 10g, 11 ms half sine wave; vibration of.5 Grms up to 30 Hz; 300 V positive/negative pulses applied at one pulse per second at minimum and maximum DC supply voltage; stored at -49ºF (-45ºC) for 24 hours; stored at 185ºF (85ºC) for 24 hours; operation at -29.2ºF (-34ºC) and 10.8 VDC; operation at -29.2ºF (-34ºC) and 26.5 VDC; operation at 165.2ºF (74ºC) and 26.5 VDC; operation at 165.2ºF (74ºC) and 10.8 VDC Device is tested by the manufacturer before shipment Click 210/210-02 Specifications Weight: 0.07 lbs. (31.8 g) dimensions: 0.3 in. x 2.5 in. x 3.4 in. (0.08 cm x 6.4 cm x 8.6 cm) Ambient operating temperature: -4 F to 140 F (-20 C to 60 C) Nominal operating voltage: 250 VAC, 65 VDC Click 210 nominal current: 0.5 A Click 210-02 nominal current: 2 A Two screw terminals for wiring in and out Configuration Feature Push-button used to reset device after a current interruption Fuse Slow-blow fuse Switching Capacity Switching capacity: 6x IN for nominal currents 0.25 A to 4 A Life Expectancy Life expectancy: 3000 cycles Passes manufacturer s test before shipping Click 222 Specifications Weight: 0.35 lbs (0.15 kg) dimensions: 4.5 in. 4 in. 0.9 in. (11.4 cm x 10.2 cm x 2.3 cm) Ambient operating temperature: -29 F to 165 F (-34 C to 74 C) Humidity: up to 95% RH Hot-swappable Pluggable screw terminals for easy pre-wiring: 1 pair for DC power, 2 terminals for protective earth, 4 pairs for RS-485 communication (485A, 485B, 485C, 485D) 3 RJ-11 jacks for connecting to detector rack cards: one connected to 485A, one to 485B, one to 485C and 485D 5-position connector for power and RS-485 to and from the T-bus Communications Routes RS-485 communications between screw terminals, 5-position connector, and RJ-11 jacks RJ-11 jacks labeled RS-485 A and RS-485 B send contact closure information to rack cards RJ-11 jack labeled RS-485 Bridge connects to the device s control bridge, which electrically isolates RS-485 buses connected to it for more reliable communication; also connected to T-bus Three-stage Protection First stage: gas tubes Second and third stages: inductors and TVS diodes (power) or resistors and TVS diodes (communication) DC Protection Complies with the applicable standards stated in the IEC 61000-4-5 class 4 standard for DC power lines Maximum working voltage: 28 V Test results available for the following test conditions: surge voltages ±0.5kVA, 1kVA, 2kVA and 4kVA; common mode (input to ground); differential mode (input to input); 8x20µs waveform; 2 ohm generator impedance; 1-minute pause between surges RS-485 Protection Complies with the applicable standards stated in the IEC 61000-4-5 class 4 standard for communication lines Maximum working voltage: 5 V Test results available for the following test conditions: surge voltages ±0.5kVA, 1kVA, 2kVA and 4kVA; common mode (input to ground); differential mode (input to input); 8x20µs waveform; 12 ohm generator impedance; 1-minute pause between surges NEMA TS2-1998 Complies with the applicable standards stated in the NEMA TS2-1998 Standard Test results available for each of the following : 300 V positive/negative pulses applied at one pulse per second at minimum and maximum DC supply voltage; stored at -49ºF (-45ºC) for 24 hours; stored at 185ºF (85ºC) for 24 hours; operation at -29.2ºF (-34ºC) and 10.8 VDC; operation at -29.2ºF 3

(-34ºC) and 26.5 VDC; operation at 165.2ºF (74ºC) and 26.5 VDC; operation at 165.2ºF (74ºC) and 10.8 VDC Passes manufacturer s test before shipping Click 230 Specifications Weight: 0.2 lbs. (0.1 kg) dimensions: 0.7 in. X 2.6 in. X 3.5 in. (1.8 cm x 6.6 cm x 8.9 cm) Ambient operating temperature: -40 F to 185 F (-40 C to 85 C) Nominal operating voltage: 120 VAC Nominal current In: 26 A Maximum continuous operating voltage: 150 VAC Maximum discharge current (8/20μS): 10 ka Eight screw terminal connections: line, neutral and ground out; line, neutral and ground in; and two testing terminals Surge Protection Three-stage surge protection: fast-responding surge-arresting diodes; high-powered current-handling gas discharge tubes; series decoupling elements T-bus 5-screw Terminal Block Specifications imensions: 0.8 in. x 0.7 in. x 0.43 in. (2 cm x 1.7 cm x 1.1 cm) Weight: 0.009 lbs. (0.39 g) Pitch: 0.15 in (0.38 cm) Comes in left and right end models for correct assembly (this backplate comes with left end model) Nominal current: 8 A Nominal voltage: 160 V Type of connection: screw terminal connection Number of positions: 5 Wire: 30 14 AWG T-bus Connector Specifications Dimensions: 1.4 in. x 1.2 in. x 0.7 in. (3.5 cm x 3 cm x 1.7 cm) Weight: 0.01 lbs. (4.5 g) Comes in two models: green for data and power, gray for power only Nominal current IN: 8 A Nominal voltage UN: 150 V End Bracket Specifications Weight: 0.01 lbs. (6.2 g) dimensions: 0.37 in. x 2.2 in. x 1.6 in. (0.9 cm x 5.5 cm x 4 cm) Passed manufacturer s mechanical and material SC to Plug SC 10 AWG Terminal Blocks Specifications dimensions: with plug 0.25 in. x 2.2 in. x 2.4 in. (0.6 cm x 5.5 cm x 6 cm); without plug 0.25 in. x 2.2 in. x 1.4 in. (0.6 cm x 5.5 cm x 3.6 cm) Insulating material: PA Insulating material group: I Flammability: UL 94 V0 Number of connections: 2 Pollution degree: 3 Ambient operating temperature: -67 F to 212 F (-55 C to 4 www.wavetronix.com

100 C) Plug connector comes in left, middle and right models for correct assembly Matching end cover protects exposed conductor Nominal current IN: 32 A Nominal voltage UN: 800 V Maximum load current: 32 A Terminal block base connect: spring cage Terminal block plug connect: spring cage Removable plug Wire: 28 10 AWG Stripping length: 3/8 in. (0.95 cm) Internal cylindrical gage: A3 Color Coding Comes in three different models: gray (standard); green (earth ground); and blue (used to color-code plugs to ensure correct placement) Ground Green block is grounded via metal foot to DIN rail Rated surge voltage: 6 kv Surge voltage category: III Connection in acc. with standard: IEC 61984 One-year warranty against material and workmanship defect IDC to Plug IDC Terminal Blocks Specifications dimensions: with plug: 0.2 in. x 2.1 in. x 2.6 in. (0.5 cm x 5.3 cm x 6.6 cm); without plug 0.2 in. x 2.1 in. x 1.45 in. (0.5 cm x 5.3 cm x 3.7 cm) Insulating material: PA Insulating material group: I Flammability: UL 94 V0 Pollution degree: 3 Ambient operating temperature: -67 F to 212 F (-55 C to 100 C) Plug connector comes in left, middle and right models for correct assembly Matching end cover protects exposed conductor Nominal current IN: 17.5 A Nominal voltage UN: 500 V Maximum load current: 17.5 A Number of connections: 2 Terminal block base connect: insulation displacement Terminal block plug connect: insulation displacement Removable plug Wire: 24 16 AWG Color Coding Comes in three different models: gray (standard); green (earth ground); and blue (used to color-code plugs to ensure correct placement) Ground Green block is grounded via metal foot to DIN rail Rated surge voltage: 6 kv Surge voltage category: III Connection in acc. with standard: IEC 61984 Traffic Cabinet Backplate Specifications Material: aluminum Thickness: 0.125 in. (0.32 cm) Rack space requires: 5 U (1.75 in/4.4 cm) dimensions: 8.625 in. x 7.594 in. x 19 in., handles included (21.9 cm x 19.3 cm x 48.3 cm) Number of DIN rails: 2 The advertised detection accuracy of the company s sensors is based on both external and internal testing, as outlined in each product s specification document. Although our sensors are very accurate by industry standards, like all other sensor manufacturers we cannot guarantee perfection or assure that no errors will ever occur in any particular applications of our technology. Therefore, beyond the express Limited that accompanies each sensor sold by the company, we offer no additional representations, warranties, guarantees or remedies to our customers. It is recommended that purchasers and integrators evaluate the accuracy of each sensor to determine the acceptable margin of error for each application within their particular system(s). 5

Intersection Preassembled 19-inch Rack Bid Specification 1.0 General. This item shall govern the purchase of a preassembled 19-inch rack (PR) equivalent to the Wavetronix intersection preassembled 19-inch rack, as part of a system involving a radar presence detector (RPD) system or a continuous tracker advance detector (CTAD) system. 2.0 Product Description. The PR shall be a preassembled 19-inch rack to be installed in a server rack. The PR shall include the following elements (where multiple models of the same device are listed, their use depends on whether the PR is meant to support two or four sensors): a DC power supply equivalent to the Click 202/204; circuit breakers equivalent to the Click 210/210-02; an AC surge suppresion device equivalent to the Click 230; a system surge protection device equivalent ot the Click 222; T-bus connectors; end blocks; terminal blocks for sensor cable termination; terminal blocks for AC line input; end blocks for stabilization and spacing; and a 19-inch rack as a mounting platform. 6 www.wavetronix.com