Federation of European Heating, Ventilation and Air-conditioning Associations



Similar documents
Federation of European Heating, Ventilation and Air-conditioning Associations

Field test of a novel combined solar thermal and heat pump system with an ice store

Renewable Heat Pumps. A guide for the technically minded

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

SOLEL SUNCOOLER SOLAR-POWERED AIR-CONDITIONING / HEATING SYSTEM

Building Energy Systems. - HVAC: Heating, Distribution -

Exploitation Tests of Borehole Heat Exchangers in the Laboratory of Renewable Energy Sources in Miekinia Poland

New technical solutions for energy efficient buildings

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

Radiant Heating and Cooling Systems BY KWANG WOO KIM, ARCH.D., MEMBER ASHRAE; BJARNE W. OLESEN, PH.D., FELLOW ASHRAE

ENERGY PILE AND HEAT PUMP MODELING IN WHOLE BUILDING SIMULATION MODEL

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov to Mar. 15, 2004.

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

Hybrid heat pumps. saving energy and reducing carbon emissions

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

6 18 A steam power plant receives heat from a furnace at a rate of 280 GJ/h. Heat losses to the surrounding air from the steam as it passes through

AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Smart building as a power plant energyplus house with energy charge management

ENERGY BALANCE OF LOW ENERGY HOUSE WITH GHPS IN HOKKAIDO

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

Creating Efficient HVAC Systems

DEVELOPMENT OF AN OPEN SOURCE HOURLY BUILDING ENERGY MODELING SOFTWARE TOOL

Integrated Solar Radiant Systems

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Energy Efficient HVAC-system and Building Design

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

White Paper Nest Learning Thermostat Efficiency Simulation for France. Nest Labs September 2014

FACTSHEET Assessing the Feasibility of Using Solar-Thermal Systems for Your Agricultural or Agri-Food Operation

A heat pump system with a latent heat storage utilizing seawater installed in an aquarium

Glossary of Heating, Ventilation and Air Conditioning Terms

Daikin Altherma hybrid heat pump. The natural combination

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS

How a Ground Source Heat Pump Works for a School or College

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

The natural ombination

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

SWISSOLAR 2104 TASK 44 SOLAR AND HEAT PUMP SYSTEMS

Best Practice Guide. Heat Pump Technologies

ROTEX gas hybrid heat pump. A strong team.

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

3-D Modeller Rendered Visualisations

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Time to Rethink Heating

Geothermal Heat Pump Systems

SONNENKLIMA package solution description

Study on Performance Evaluation of a Split Air Conditioning System Under the Actual Conditions

Natural geothermal energy.

Life cycle cost comparison of TAB vs. other HVAC (UK) TECHNICAL BROCHURE

How To Save Energy With High Pressure Control

Energy Efficiency in Buildings

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Crowne Plaza Copenhagen Towers The world s greenest hotel

Daikin Altherma Hybrid Heat Pump

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Small-Scale Solar Heating and Cooling Systems

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

Gas Absorption Heat Pumps. Future proofing your heating and hot water

Daikin Altherma Hybrid Heat Pump

How a Ground Source Heat Pump Works for Commercial Buildings

LG Electronics AE Company, Commercial Air Conditioning

Optimising Energy Use in Cities through Smart Decision Support Systems

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

New absorption chillers for high efficient solar cooling systems

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

How To Use A Water Source Heat Pump

Adaptive strategies for office spaces in the UK climate

Case study on residential building renovation and its impact on the energy use and thermal comfort

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Contract No.: IEE/08/776/SI

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Energy savings in commercial refrigeration. Low pressure control

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

Design and Implementation of Geothermal Systems for Heating and Air Conditioning

An Overview of Solar Assisted Air-Conditioning System Application in Small Office Buildings in Malaysia

FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST

Final Report by Air Conditioner Evaluation Standard Subcommittee, Energy Efficiency Standards Subcommittee of the Advisory Committee for Natural

Design and Re-Use Of Shovadans In Today's Architecture "With Due Attention To Have Thermal Energy Of The Earth"

HEATING-COOLING WALL PANELS SYSTEM IN SLOVENE ETHNOGRAPHIC MUSEUM

RECENT DEVELOPMENTS IN GROUND SOURCE HEAT PUMP RESEARCH. Jeffrey D. Spitler Oklahoma State University

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

CRK24-B1 Heated/chilled ceiling system

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

SOLAR ENERGY How much strikes the earth? How much can my building get? When is it too much?

Condensing Boiler Efficiency

Software Development for Cooling Load Estimation by CLTD Method

Transcription:

Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu info@rehva.eu Tel: +32 2 514 11 71 Fax: +32 2 512 90 62

REHVA Guidebook No 20 Advanced system design and operation of GEOTABS buildings Franziska Bockelmann Stefan Plesser Hanna Soldaty

List of content 1. Terminology, Symbols and Units 2. Introduction 3. What is GEOTABS? 4. Possibilities and Limitations of GEOTABS 5. GEOTABS: Designing the Ground System 6. GEOTABS: Designing the Building 7. GEOTABS: System Integration 8. GEOTABS: Commissioning, Operation & Maintenance 9. Outlook 10.GEOTABS Buildings Diversity of Solutions References

Terminology Geothermal energy Energy stored below the surface of the solid earth in the form of thermal energy. Heat pump Heat pumps are thermodynamic cycles by means of which low temperature ambient energy can be upgraded such that it can be utilized for heating (heat pump) or cooling (chiller) buildings. The ambient energy is extracted from the ambient air, the groundwater or the ground soil. By using electrical power the temperature is brought to the desired temperature. Thermally Activated Building System (TABS) Radiant heating and cooling systems with pipes embedded in the building structure (slabs, walls).

What is GEOTABS? GEOTABS is an acronym for a geothermal heat pump combined with a thermally activated building system, used for conditioning of a building in three possible modes: heating with a heat pump passive cooling active cooling with a reversible heat pump

TABS The TABS is a building component with embedded water based pipes used for heating and cooling the building. The principle of the system is to activate the thermal mass of the building to transfer heat to or from the zone to assure thermal comfort in the rooms.

TABS The system can be effectively used in combination with renewable energy sources and heat pump for: low temperature heating (27-29 C) high temperature cooling (18-22 C)

TABS Drift of the indoor temperature in a TABS building (example: summer) TABS should be used for zone control - not for individual room control!

Heat pump Principle of the heat pump: Types of heat pumps: in regard to heat source: air, water or ground coupled heat pumps in regard to supply energy source: electrical, gas or oil combustion in regard to conversions: compressor, absorption or adsorption

Near surface geothermal energy systems Closed systems Horizontal heat exchanger Energy piles Borehole heat exchanger Slabs as ground absorber Open systems Wells

Seasonal thermal balance in the ground Underground Thermal Energy Storage (UTES) - combined heat source and heat sink

Seasonal thermal balance in the ground Only heat source Only heat sink Regeneration of the natural thermal balance of the soil must be assured!

Opportunities Threats Strength Weakness Possibilities and limitations of GEOTABS 1. Water supply temperatures: <30 C for heating >15 C for cooling exploiting environmental energy: (ground coupled) heat pumps, passive cooling and night cooling. 2. Large thermal capacity (time constants of 10-15h) to shift TABS operation to time periods when heat and cold production is most energy (or cost) efficient. 3. Increased thermal comfort by radiation heat exchange. 4. Reduced building height compared to buildings with full AC. 1. Limited average thermal power output of 40 to 50 W/m². Allow temperature drifts within the specified comfort range or provide an additional, fast reacting system. 2. Limited individual room control. 3. Not useful to change set-point during a day. 4. Acoustic control - limited suspended ceiling. 1. Suitable for low energy, passive or zeroenergy buildings. 2. Increased share of efficiently generated heat and cold. 3. Less expensive and more energy efficient form of cooling than full air-conditioning. 1. Careful system and control strategies design is required. 2. Additional fast reacting system must not overrule or counteract the TABS operation. 3. The limits of the system regarding the achievable thermal power should be specified.

Design process

Designing the ground system Realization of a geothermal system requires adaptation to the geological constraints on site: rock type and hardness ground thermal characteristic groundwater situation natural ground temperature A thermal response test (TRT) and exploration of the soil can provide information on the suitability for geothermal systems.

Simulation of the ground system Simulation is particularly useful to study: the thermal response of different borehole configurations interference between boreholes annual energy balance of the ground Types of simulations: coupled simulations (TRNSYS, equest, EnergyPlus, Modelica) decoupled simulations (Earth Energy Designer EED, EWS Erdwärmesonden)

Designing the building The main restrictions for the design are related to: mass of the building external gains and losses related mostly to location, orientation, layout (internal, external and corner rooms), ventilation and solar radiation internal loads transmission

Simulation of the building Simulation in design of the GEOTABS building on: building level room level TABS level Example of the temperature profile output of building simulation with TABS

System integration Heat pump in combination with the additional heating or cooling system operation modes: monovalent bivalent alternative bivalent parallel bivalent partially parallel monoenergetic Heating with integrated district heating

System integration Passive cooling Active cooling Cooling with integrated cooling tower

System integration buffer tank Buffer tank to avoid frequent on/off switching of the heat pump, when: the supply system contains only a small amount of water it is running at very low loads the supply system can be turned off completely

Efficiency of the system Coefficient of Performance (COP) the ratio of heat power to electric power referred to particular boundary conditions (calculated value) Seasonal Performance Factor (SPF) the ratio of annual thermal energy output to the annual consumed electrical energy (measured value)

Control strategies for the ground system Conventional control strategies: Intermittent operation with defined schedules: with a dead band for a specific range of temperatures or with seasonal downtime only during occupation hours (night setback) independent from occupancy time, when the energy tariffs are lower (night cooling) Rules for ground system control: avoid frequent switching between operation modes decrease unnecessary consumption of auxiliary energy

Control strategies for TABS Conventional control strategies: Time based control Zone temperature control Weather dependent supply/average water temperature control Intermittent pump operation control Constant concrete core temperature control Dead band for switching between heating and cooling mode

Control strategies for TABS Rules for TABS control: keep TABS at a constant temperature concrete surface temperature is the controlled variable, water temperature is the manipulated variable heating on, if average outdoor temperature is lower than set point cooling on, if average outdoor temperature rises above the set point heating/cooling curve +3K / -3K

Control strategies for additional systems Conventional control strategies: operation of the TABS system during night and use fast reacting system during daytime operation of fast reacting systems at moderate ambient air temperatures activation of the TABS when the building is constantly in heating or cooling mode Rules for fast reacting system control: fast reacting systems must not overrule the TABS in regular operation simultaneous heating and cooling must be avoided frequent changing between heating and cooling must be avoided

Control strategies Model Predictive Control Model Predictive Control (MPC) framework:

Commissioning, operation & maintenance Commissioning is an essential requirement for GEOTABS systems in commercial buildings to ensure that the system operates in the intended way! Commissioning process Step 1: Definition of objectives Step 2: Definition of measurement and verification concept Step 3: Initial Commissioning Step 4: On-going Commissioning

Real cases Hollandsch Huys Location Hasselt, Belgium Year of construction 2008 Net floor area (NFA) 4 090 m² Gross volume 12 975 m³ Geothermal system Borehole Heat Exchanger (22 à 75 m) Design values Total heating load 37 kwh/m² NFA Total cooling load 27 kwh/m² NFA Fraction of geothermal system Heating: 100% Cooling: 100% Summer and winter energy concept

Real cases INFRAX West Location Torhout, Belgium Year of construction 2009 Net floor area (NFA) 4 014 m² Gross volume 21 484 m³ Geothermal system Borehole Heat Exchanger (24 à 130 m) Design values Total heating load 409 kw 71 kwh/m² NFA Total cooling load 242 kw 49 kwh/m² NFA Fraction of geothermal system Heating: 69% Cooling: 67% Summer and winter energy concept

More GEOTABS cases with building characteristic and operation data at: www.geotabs.synavision.de

Thank you for your attention To order the REHVA guidebooks : www.rehva.eu / section Bookstore or through your national member