Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments



Similar documents
Making sense of Intrinsic Safety and Intrinsically Safe Tools

Class/Division Hazardous Location

Hazardous Area Classifications and Protections

Electric motors can pose a serious threat when they are

Basics of Explosion Protection

HAZARDOUS AREA TECHNICAL GUIDE

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Zone Hazardous Location

Hazardous Area Classifications and Protections

Fire Alarm System Accessories

Classification of Hazardous Atmospheres

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

Early Fire Detection & Condition Monitoring

Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO

SafeSite LED RTO Area Light - UL844. for Indoor and Outdoor Industrial Applications #

NEMA Enclosure Types

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

How To Protect An Explosion

By: Santiago Consunji American Industrial Systems, Inc.

INTERNATIONAL STANDARD

THE DETECTION OF GREENHOUSE GASES

Professional Series ATEX Portable Radios

TABLE OF CONTENT

Wireless Remote Video Monitoring

Combustible Dust - Things that go Boom. W. Jon Wallace, CSP, MBA Workplace Group, LLC O: E: jwallace@workplacegroup.

Electrical Classification

Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure November 2010

CONSULTING Training Courses

SURVIVE INSIDE: Employee Safety in Confined Spaces

Electrical Equipment in Hazardous Areas: Field Inspections

Intrinsically Safe Barrier Relays NY2 and 8501TO

ATEX Fans 08/02/2008. Data subject to change without prior notice

Article Scope Definitions. Article 505. Class I, Zone 0, 1, and 2 Locations. 52 Cooper Crouse-Hinds Code Digest

ABSTRACT INTRODUCTION

Wireless Remote Video Monitoring

Instructions for Safe Use

distributing & controlling system solutions

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

The Extreme Series Surveillance solutions for extreme environments

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Application Requirement

Design, testing, certification, installation & maintenance

Hazardous Locations Training

Products Solutions Services. CompEx training From the process safety experts

Guide For Proper Use of. Intrinsically Safe Fire Protection Devices

Explosion Prevention

Safety instructions VEGADIS DIS81.CEIA/V****

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

9/15/2011. Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration

99/92/EC (ATEX 137) USE

Gas Leak Detection and Visualization.

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

General Confined Space Awareness

Presented by: Rich Perry Marsh Risk Consulting

CLASSIFICATION NOTES

How to Select a Flame Detector

Brochure. ABB Customer Training Program for Motors and Generators Sharing knowledge and creating value

Natural Gas Information Contents

of Protecting Professionals through Innovative Lighting

Area Classification Why? Where? How? Who? When?

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Combustible Dust Booklet

FIRE PREVENTION PLAN

IP Rating Chart. 910 East Orangefair Lane Anaheim, CA USA , Fax

Hazardous location. Definitions

READ FIRST. Confined Space Entry Procedure. San José State University Environmental Health and Safety. Confined Space Entry Procedure

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Cat Detect. for Surface Mining Applications

Hazardous Substance Class Definitions & Labels

The Globally Harmonized System and OSHA Hazard Communication Revision

Fossil fuel heating equipment

Explosion proof enclosures

FLA S FIRE SAFETY INITIATIVE

Eni experience and research with IR video-camera imaging

Failure Analysis Associates. Cell Phone Usage At Gasoline Stations

WEEKLY SAFETY MEETING All Euramax Subsidiaries COMBUSTIBLE DUST. Safety Meeting Contents. Meeting Notice. Leaders Guide.

Assessing the Potential for a Dust Explosion and Navigating the Current Regulatory Environment

Controlling fire and explosion risks in the workplace

Terminal Box. Specifications TNCN

Commercial Garages, Repair, and Storage

Installation Instructions for Alarm Module Kit A043F059

Contents. 1. Legal Requirement Responsibility of Related Parties What are Confined Spaces Hazards Identification 4

MACHINE VISION ORIENTATION SENSOR THERMAL IMAGING 3D VISION DEEP LEARNING THERMAL IMAGING.

COMBUSTIBLE DUST EXPLOSIONS

2CMC300001D0003 November Enclosed switches ATEX

SECTION 1 IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. 129 Lockwood St CHEM-TEL (24 hour)

Hazardous Areas Motors

SAFETY DATA SHEET 安 全 数 据 单

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Flame detection across the spectrum. Range Brochure

Confined Space Safety Part I Entry Hazards and Controls

Siemens TMDS transformer monitoring and diagnostic system. Solutions for transformer life-cycle management. Answers for energy.

Gas-Fired, Residential Storage Type Water Heaters

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Spray Booth Guideline

Wilkins Safety Group

FDNY C14 Certificate of Fitness Quiz

Transcription:

Video Systems Explosion Protected White Paper Series Imaging Challenges in Explosive Environments Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments Introduction Extraordinary considerations must be taken when using electronics in certain industrial environments. The first publication of our Explosion Protected white paper series will provide an overview of security applications in potentially explosive environments, highlighting the history, terminology, and industry standards for explosion protected surveillance equipment. We will also bring to light the difficult imaging challenges that are presented in critical industrial facilities and the current landscape of imaging and illumination technologies that are available for explosion protected environments. History: The need for explosion protected surveillance equipment The need for certified explosion protected electronic equipment started in the early mining days in 1913 when 439 miners perished in a disastrous explosion. It was the worst disaster in British coal-mining history and its cause was found to be the low voltage signaling bells which in tragic irony, were brought in to improve communication and promote safety. It was then surprising to learn that these communication devices could ignite the methane gas that would typically permeate a coal mine. Now, in the present day there is a growing need to install various types of electronic equipment in mines and other types of industrial facilities. The installation of electronic equipment in these modern industrial environments must be "explosion protected," which means the equipment is designed to prevent the ignition of explosive environments. National and international standards have been put in place and are enforced by law to ensure industrial facilities are using explosion protected equipment in areas that are deemed necessary. There is also a growing need to have high quality and certified explosion protected surveillance equipment in a nation s primary and secondary industrial facilities. In the UK, oil refineries, chemical plants and gas plants have long been monitored with video solutions for protection against terrorist attacks and crime. Globally we have only begun to protect our factories with video surveillance. Moreover, the industry is finding that the use of video solutions in factories is an important tool in maintaining safe operation. Factory managers can monitor people, processes and equipment to ensure good operation and safety practices. Video solutions (instead of people) can be located where there are hazardous or unhealthy conditions. Automated factories can utilize smart video technologies to verify or trigger alarms if a process has gone awry. Many factories use "machine vision," where sophisticated video optics is an integral part of the industrial process. The meaning of explosion protected Within the security industry, it is often thought that explosion protected products are capable of withstanding an external explosion, such as a bomb blast. While explosion protected cameras are typically rugged and may very well survive an explosion, this is not the design intent. The term explosion protected, in fact, refers to an electronic device that, after being properly installed in a combustible atmosphere, will not cause an explosion even under fault conditions. Protection methods used for explosion protected devices include Flameproof and Explosionproof (used respectively in Europe and the Americas) or intrinsically safe. Certified explosion protected equipment using the explosionproof method is able to withstand an internal explosion in order to not let any flames escape the housing and ignite the surrounding areas. The external enclosure of this type of equipment would include flame paths, which are small gaps that extinguish the flames and cool hot gases, allowing the gases to escape the enclosure so that they are unable to ignite the outer atmosphere. Devices typically include switches, control systems, motors, transformers, lights and, of course, surveillance equipment. Intrinsically safe equipment use circuits, which are energy limited and incapable of producing a spark or any volatile thermal effects under normal or fault conditions. Devices typically include radios, measurement and control, actuators and sensors.

Explosion Protected White Paper Series Imaging Challenges in Explosive Environments 2 Industry standards for explosion protected surveillance equipment There are various industry standards that are available for explosion protected surveillance equipment. In North America, standards are based on the Class, Division system for hazardous locations. In Europe and other parts of the world standards are based upon the Zone System for potentially explosive atmospheres. We will cover both systems in detail below. Classes, Divisions and Hazardous Locations In North America, hazardous locations are identified by Class, Division, and Group as defined in the NEC (National Electrical Code) and CEC (Canadian Electrical Code). The system provides three Classes based on the type of hazard and explosive characteristics of the material, two Divisions based on the operating conditions and seven Groups based on flammability properties. Environments are further defined by 14 temperature codes for Auto-Ignition Temperatures of the flammable gases that might be encountered. Knowing the meaning of NEC/CEC codes is critical to understanding precisely the requirements of explosion protected surveillance equipment in explosive environments in North America. Below is the list of NEC/CEC codes in terms of types of flammable atmospheres, operating conditions, flammability properties, and temperature codes with detailed descriptions of what they mean. Class Division Group NEC/CEC CODES I Locations with flammable gas or vapor II Locations with flammable dust III Locations with flammable fibers or flyings 1 Explosive conditions exist under normal operating conditions 2 Explosive conditions exist under abnormal operating conditions A Acetylene B Hydrogen C Ethylene, Ethyl Ether, Cyclopropane, Butadiene Propane, Ethane, Butane, Benzene, Pentane, Heptane, Acetone, D Methyl Ethyl, Ketone, Methyl Alcohol, Ethyl Alcohol Electrically Conductive Dusts: Aluminum, Magnesium, Titanium, Zinc, E Tin + others F Carbonaceous Dusts: Carbon Black, Charcoal, Coal, Coke Dusts G Agricultural Dusts: Grain, Flour, Sugars, Spices and certain Polymers The Temperature Code shown in the chart below defines the maximum surface temperature of the equipment, which must not exceed the auto-ignition temperature of the gases present in the explosive environment. Acetylene gas, for example, has an auto-ignition temperature of 299 degrees Celsius. Therefore, an explosion protected device installed where there is a potential air/acetylene mix must have a T-rating of T2A to T6. Temperature Code C T1 450 T2 300 T2A 280 T2B 260 T2C 230 T2D 215 T3 200 T3A 180 T3B 165 T3C 160 T4 135 T5 100 T6 85

Explosion Protected White Paper Series Imaging Challenges in Explosive Environments 3 For Class I Div 1 locations, the allowable protection methods include: explosionproof, intrinsic safety (2 fault) and purged/pressurized (type X or Y) methods. For Division 2 locations the allowable methods are: hermetically sealed, nonincendive, non-sparking, purged/pressurized (type Z) and any Class I Div 1 method. This implies that any device made for Div 1 locations is suitable for use in a Div 2 environment. The Zone System and Potentially Explosive Atmospheres In Europe and many other regions of the world, potentially explosive atmospheres are handled by using a zone system based off IEC (International Electrotechnical Commission) and CENELEC (European Committee for Electrotechnical Standardization) standards. The EU (European Union) adopted Directive 94/9/EC also known as the ATEX Directive to facilitate free trade in the EU by aligning legal and technical requirements across Member States. Therefore, knowing the meaning of ATEX codes would be critical in understanding the requirements of explosion protected surveillance equipment in explosive environments in Europe and the rest of the world. Below is the list of ATEX codes in terms of device groups, categories, temperature class, explosion group, and types of ignition protection with detailed descriptions of what they mean. ATEX Zone CLASSIFICATION OF EXPLOSIVE ATMOSPHERES NEC/CEC Division Equivalent Definition * consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is present continuously or for long periods or frequently. consisting of a mixture with air of flammable substances in form of gas, vapor or mist is likely to occur in normal operation occasionally. consisting of a mixture with air of flammable substances in form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. in the form of a cloud of combustible dust in air is present continuously, or for long periods or frequently. in the the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally. in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only. 0 1 1 1 2 2 20 1 21 1 22 2 * Per 1999/92/EC Directive (ATEX 137) Required Device Category* Atmosphere 1 G 1 2 G 1 2 3 G 1 D 1 2 D 1 2 3 D

Explosion Protected White Paper Series Imaging Challenges in Explosive Environments 4 ATEX classification codes

Explosion Protected White Paper Series Imaging Challenges in Explosive Environments 5 Example showing ATEX Zones and NEC/CEC Divisions Getting the image in explosion protected environments Minimizing the possibilities of accidental damage to equipment and ensuring security and safety of workers have become more prevalent concerns in critical facilities over the years. Having reliable video verification of events in critical facilities allows operators to be in control of a potential crisis around-the-clock, even in most difficult lighting conditions. In particular, surveillance equipment that provides the right level of detail can enhance the accuracy of tough judgment calls operators are forced to make during a crisis. Often a simple judgment call of whether one should send his fellow colleagues to investigate a site of concern can turn into a life and death situation in the matter of minutes in explosion protected environments. Factories and industrial facilities today are all controlled and monitored by a process system, more commonly referred to as a Supervisory Control and Data Acquisition / Distributed Control System (SCADA/DCS) process. Using real-time video verification in a SCADA/DCS process can not only help analyze system efficiency but assist in scenarios where a proactive approach can be taken in potentially dangerous situations. An increasing amount of camera installations are found on drill floors of offshore oil rigs, around critical processes at refineries, and near critical equipment, such as petroleum storage tanks. Generally, these locations have a range of difficult natural lighting conditions such as a bright ocean background over a dark foreground typically found on the deck of an offshore rig. These critical sites can have a range of difficult artificial lighting conditions, such as shadow casting and uneven illumination. When problems occur in locations where it is challenging to capture a good image, operators are unable to inspect visually what is going on and lose valuable time that might just be needed to prevent a minor problem from becoming a major one. Different types of modern imaging and illumination technologies are available to handle the imaging challenges that are typically faced in explosion protected environments.

Explosion Protected White Paper Series Imaging Challenges in Explosive Environments 6 Modern imaging technologies Modern imaging technologies, such as 20-bit digital signal processing, can expose details not visible to the naked eye in both day and night times. 20-bit digital signal processing generates two images to produce the clearest picture for every scene: one long exposure resolves details in scene s darkest areas, while one short exposure captures the brightest areas. The processing then mixes the pixels from each image to produce the most detailed picture possible. The 20-bit digital signal processing also uses state-of-the-art software to analyze and enhance each pixel. Image quality at different processing rates Conventional image processing 20-bit processing

Explosion Protected White Paper Series Imaging Challenges in Explosive Environments 7 Active Infrared illumination technology Active infrared illumination technology can help operators detect, classify, recognize, and identify targets not visible to the naked eye at night time. It is considered an inexpensive method of obtaining high quality images in low light conditions. Active infrared illumination technology also provides discrete illumination for security video and minimizes light pollution. Without IR Conventional IR Advanced Infrared illumination technology Having advanced active infrared illumination technologies supplementing explosion protected cameras ensure security and operational professionals high quality images in any lighting conditions, even in difficult nighttime and low-light environments. These advanced active infrared illumination technologies are able to provide three key benefits. First, they can effectively illuminate the foreground and background providing light where the camera needs it. Second, they can eliminate hot spots and underexposures, ensuring consistent lighting across any scene and enabling video analytics to immediately detect security and safety threats. Third, they can minimize LED degradation, ensuring quality data throughout the life of explosion protected surveillance equipment and across the operation temperature range of the product. In addition, modern LED lighting draws much less power than conventional lighting, making explosion protected equipment with modern LED lighting more energy efficient. Conventional IR Advanced IR

Explosion Protected White Paper Series Imaging Challenges in Explosive Environments 8 Conclusion Surveillance related issues have been increasingly challenging, especially for explosion protected environments, and having high quality and certified explosion protected surveillance equipment in a nation s primary and secondary industries has been progressively more vital to the health of a nation s infrastructure. It has not been easy for security and operational professionals to find the right surveillance cameras for their critical facilities, and it has been increasingly important for these professionals to have explosion protected cameras that perform flawlessly in natural and artificial light. With its imaging prowess, Bosch has been a field-proven expert in security for explosive environments. For more information regarding the technologies mentioned in this white paper and our experiences with critical industrial facilities, please refer to the Bosch Imageology and Hazardous Locations websites for details. Bosch Imageology: http://www2.boschsecurity.us/imageology/ Bosch Hazardous Locations: http://www.boschsecurity.us/en-us/markets/hazardous/default.htm