EUROTHERM FLEXIBLE SOLUTIONS UNIT CONTROLLER FOR INTELLIGENT DATA ACQUISITION AND PRECISION CONTROL APPLICATIONS



Similar documents
EUROTHERM FLEXIBLE SOLUTIONS. Plastics ADDING VALUE AT EVERY LEVEL OF THE PLASTICS INDUSTRY

EUROTHERM MASTER COMMUNICATIONS 5000 Series with Master Communications for unsurpassed access to process data everywhere

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

Agilent 4338B Milliohm Meter

Process Alarm Solutions

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ISO 9001 Certified BC D2/E

Think Automation and beyond... IDEC WindSRV. KEPServerEX OPC Server

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Technical Information POWER PLANT CONTROLLER

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Modbus Server SAMSUNG Air Conditioners

Vibration analysis and monitoring Compact. Powerful. Modern technology.

+ A B V B NO NC V COM PV PV

Controller Automation, Model II+

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

abc Operations Viewer and Server Product Data MODELSOpsF,OpsS,OpsW

Data Center.

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

APPLICATION-SMART CONTROL

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

IntesisBox Modbus Server SAMSUNG Air Conditioners

Agilent 4339B/4349B High Resistance Meters

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Environmental Monitoring System (EMS) Architectures

Agilent Automotive Power Window Regulator Testing. Application Note

How To Build A Powerline Box Powerline Generator

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

HMI and Industrial PC Solutions

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Optimize your simple machines... Modicon M218 Selection Guide

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

DC1000 Series General Purpose UNIVERSAL DIGITAL CONTROLLERS

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Simplify Data Acquisition with a Built-in LXI Web Server

Dyeing Programmer DP - 01

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Temperature Transmitter TTX300

Electronic Control Devices The European Product Catalogue 2007

Smart. Scalable. Simple.

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

PUMP CONTROL. AC Variable Speed Drive PUMP CONTROL. Energy efficient pumping with. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

How To Use A Ds340 (Dsp)

ISO 9001 Certified BC D2/E

Communication Interface Units. CIU Prime & CIU Plus

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

IntesisBox Modbus Server - Mitsubishi Electric G50

Problem / Solution. The problem:

Building Technologies

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

NEW. EVEN MORE data acquisition and test stand automation

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

T7560A,B,C Digital Wall Module

NETWORK ENABLED EQUIPMENT MONITOR

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

METROLOGIC INSTRUMENTS, INC. MS1690 Focus Area Imaging Bar Code Scanner Supplemental Configuration Guide

PRODUCT LIST Facility DDC Access WebXL DDC

NetScanner System. Toronto: , Montreal: , Toll Free: ,

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Combined Cycle Control Overview

How To Make A Fronius Cl Power Inverter

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

MOTOR CONTROL IS OUR NATURE

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

AN2680 Application note

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Intelligent Device Management with DCS, PLC, and RTU

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Get the benefits of Norgren s unique range of Online services

NXL Series Inverters. HVAC Inverters made simple

Programmable Logic Controller PLC

Smart. Productivity and performance The PLUS+1 control platform. powersolutions.danfoss.com. control systems MAKING MODERN LIVING POSSIBLE

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Wir kriegen s geregelt Close the loop with PMA

Climate Ready Shade Operating Systems for residential applications.

Easy and efficient asset management for your business

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

M2M Connectivity T: W:

Square D Powerlink G3 Lighting Control Systems

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

BUSINESS UNIT ELECTRONICS Electronic Locking, Control and Monitoring

Smart relays Zelio Logic Step into an intuitive world!

Temperature & Humidity SMS Alert Controller

Regards from the Team at Rheology Solutions.

Established Leaders in Actuation Technology. Pakscan IIS sequencer master station. Publication S112E issue 09/04

Transcription:

EUROTHERM FLEXIBLE SOLUTIONS 2500 UNIT CONTROLLER FOR INTELLIGENT DATA ACQUISITION AND PRECISION CONTROL APPLICATIONS

The 2500 modular control concept from Eurotherm offers expanded system functionality The 2500 is a unique concept combining the integrity of Eurotherm s discrete control range with easy access to fully integrated systems functionality. Scalability in size and capability, plus distribution of control and acquisition are all available in this behind the panel, cost effective package. The 2500 easily combines with modern PLCs, SCADA displays and control systems. Intelligent Data Acquisition Channel to channel isolation for reliable operation in industrial environments Standard and custom linearisations for measurement flexibility The modularity of the 2500 makes it easier to create a system with just the correct mix of inputs and outputs. This enables the distribution of the data acquisition equipment physically and saves the cost of expensive multi-core or compensation cables. Up to sixteen 2500 base units may be interconnected on a single communications line, to provide sophisticated, distributed, multi-loop control or data acquisition capabilities. Signal Conditioning Custom linearisation High/Low signal select First Order Filter Combinational Logic Mathematical functions As a signal conditioning unit, the 2500 can be configured to solve complex signal conditioning problems, such as selecting and averaging inputs before retransmitting the result. The 2500 gives programmable linking of analogue and digital inputs and outputs while offering high-speed, industrial standard, serial communications to suit your data acquisition requirements. Alarm Monitoring Eight alarms per input module Assignable user alarm functions Absolute, deviation and rate of change types Diagnostic alarms and local error indication In this comprehensive package, alarm outputs (contact trips) may be triggered by process or calculated variables. Calculated variables can be derived from a comprehensive library of maths and boolean functions. Alarms can be triggered by crossing a high or low threshold, deviation from another input or from a calculated value. Alarms may also be triggered on a rate of change basis. A uniquely flexible concept...

- and outstanding user benefits Modular concept ensures optimum flexibility Add advanced PID control to PLC installations Reduced wiring costs, simpler control panels Easy to configure, quick to install Suitable for simple and complex applications A stand-alone system or in conjunction with dedicated SCADA Enhanced Control Outputs Continuous analogue Time proportioned Motor valve control - VP bounded and unbounded Combinational heat cool Advanced combinational PID algorithms provide a choice of analogue, time proportioned or advanced motor drive outputs, providing a solution to all your control problems. Advanced Multi-loop Control Proven Eurotherm Control performance 2,4, 8 loop versions Simple, Cascade, Ratio and Override loop types Automatic PID tuning removing the need for control expertise The 2500 brings you scalable, distributed control with proven performance you can rely on. Control algorithm design is based on more than 40 years of temperature and process control market leadership.... in temperature and process control

The easy and economical way to build a distributed process control system, tailored to your needs Six base sizes allow for cost effective acquisition of up to 64 analogue or 128 digital inputs or outputs. The bases take up to 16 plug-in I/O modules and provide the flexibility for DIN rail or panel mounting. The 2500 can then be distributed where the control action is required; reducing wiring costs as only twisted pair communication cable need be taken to the user interface or PLC. Analogue I/O Universal analogue input: T/C, RTD, Pot, 0-100mV 0-10vdc, 4-20mA 4-20mA with isolated 24v supply Analogue outputs for re-transmission or control LEDs indicate sensor fail Test disconnects A unique input circuit incorporates digital filtering (Delta- Sigma filter), to ensure the high stability, accuracy and resolution expected from a Eurotherm product. The I/O provides open and short circuit monitoring and sensor fail action for most input measurements. High accuracy analogue outputs meet the most exacting demands of modern industry. Digital I/O Contact sense and logic inputs Logic and relay outputs LEDs provide direct feedback of I/O state Channel to channel isolation Output modules provide user selectable actions for on/off, time proportioned or valve position outputs. Intelligence in the output modules enables the 2500 to calculate the output timing with a higher resolution than the nominal 110m second scan rate (TPO 10mS and VP 55mS). Inputs and outputs share a common, comprehensive alarm capability. A uniquely flexible concept...

Customised Control to meet your requirements Easy multi-loop control Built in ramp function for profile applications Advanced overshoot protection Giving the best possible control for the widest range of applications Advanced PID for PLCs Dependable, accurate process control A powerful system built from standard modules Hot Swap - Reduced downtime, higher productivity The control capability of the 2500 offers up to eight control blocks; each block capable of on/off, single loop, cascade, ratio, or override control. Loop 1 Loop 2 Loop 3 Loop 4 Loop 5 Loop 6 Loop 7 Loop 8 Easy interconnection between loops makes the 2500 simplicity itself to configure for all normal control applications. Utilising the advanced toolkit and other specialist block functions, you can easily provide understandable solutions to the most complex control problems. SP PV Override Ratio Cascade Single Loop PID Valve Position Time Analogue Output Open Communications for integration flexibility Modbus Profibus DP DeviceNet Ethernet With four performance levels (data acquisition, alarm monitoring, signal conditioning and multiloop control) and six base sizes, you can select the ideal combination of capability and size for your application. However, the ease of integration of the 2500 goes much further as it directly supports a wide range of open, industry standard communications interfaces. These enable easy connection to supervisory computers, PLCs and other host systems. Up to 16 2500 base units may be interconnected, to provide distributed multi-loop control or data acquisition networks. The 2500 can share the communications bus with other devices such as discrete controllers, indicators, chart recorders and drives.... in signal conditioning and control

Eurotherm helping industry get the most out of advanced measurement and control techniques Behind the design of Eurotherm s 2500 I/O system are over 40 years of hard-earned applications experience in temperature and process control. This experience is available every time you contact Eurotherm for technical advice or product information. With well-trained experienced regional engineers throughout many countries, we are only a telephone call away from helping you solve your next measurement or control challenge. Configuration Tools Automatic network node identification Easy connectivity - drag and drop Clone file load, save and verify Application documentation Easy Commissioning OPC compliant Supports DDE - access to other Windows packages Real time trending and logging Variable scan rate itools, a Windows based PC configuration package, is used to configure and store the I/O and PID parameters as well as commission your process. A helpful multi-window browse-able format provides rapid access to Inputs, outputs, alarms PID and Toolkit mathematical functions. Combined with the itools OPC server, OPC SCOPE a powerful trending and logging package, facilitates easy commissioning by providing clear visibility of process variables through multiple time base windows. A custom sensor linearisation tool lets you download up to three special sensor characteristics for use within the acquisition, alarm or control strategy. Toolkit Block Functions Humidity calculation Carbon potential Math functions Hot swap, signal select... Logic Libraries of special Toolkit function blocks provide the 2500 with more than just the expected high standard of I/O and control. Toolkit blocks execute the mathematical or logical expressions required in creating an application. The functions are easily parameterised with itools and are wired together using drag and drop techniques. This simplifies the creation of complex applications. A uniquely flexible concept...

OPERATIONS SERVER Fast delivery Expandable - only pay for the I/O you need World wide support High density EYCON VISUAL SUPERVISOR High MTBF fault tolerant 3 Year Warranty - low cost of ownership 2500 UNIT CONTROLLER Future proof solutions - whatever your application Remote I/O Alarm monitoring Signal conditioning Distributed multi- loop Control Designed to meet the ever-growing expectations of tomorrow s industry, the 2500 provides a powerful and flexible I/O system that enables the distribution of acquisition and intelligence to the working end of the process. This, and world-beating applications knowledge and support from Eurotherm, combine to save you both time and money. Scalable solutions - grow as you go Control solutions from Eurotherm The 2500 exceeds today s rigorous industrial requirements for temperature, vibration and humidity and fulfils all relevant CE requirements.... for easier system integration

Series 2500 specifications Acquisition Toolkit Control Maximum Number of Channels per Base Loop Blocks 2 Way 4 Way 8 Way 10 Way 12 Way 16 Way I/O Types AI2 TC, PRT, POT, Volts, mv, ma 4 8 16 20 24 32 AI3 4 to 20mA with isolated 24 vdc supply 6 12 24 30 36 48 AI4 T/C, mv, ma 8 16 32 40 48 64 A02 0 to10v dc or 0/4 to 20mA 4 8 16 20 24 32 DI4 Logic or Contact sense 8 16 32 40 48 64 DI6_MV ac mains input 115V rms 12 24 32 60 72 96 DI6_HV ac mains input 230V rms 12 24 32 60 72 96 DI8_LG Logic 16 32 64 80 96 128 DI8_CO Contact 16 32 64 80 96 128 DO4_LG Externally powered 10mA 8 16 32 40 48 64 D04_24 Externally powered 100mA 8 16 32 40 48 64 RLY4 3 x N/O, 1 x C/O 8 16 32 40 48 64 Alarm Functions Analogue module 8 per module 8 per module 8 per module IS4 High absolute, 4 Low absolute assignable to any channel in the module Digital module 8 per module 8 per module 8 per module IStru, ISfalse, GOtrue, GOfalse and Change alarms. Alarms mask, Inhibit and Blocking User function block 4 per base 4 per base 4 per base Deviation high, Deviation low, Deviation band, Rate of change. All with separate hysteresis Alarm modes Latching or non-latching. Alarm Blocking Calculation Function Mathematicals 16 16 Add, Subtract, Multiply, Divide, Absolute difference, Maximum Minimum, Sample and hold, Power, Square root, Log, Ln Exponential Logic functions 16 16 AND, OR, XOR, Latch, Equal, Not equal, Greater than, Less than, Greater than or equal to, less than or equal to Carbon potential 1 1 Sooting Alarm, Automatic Probe Cleaning, Endothermic Gas Connection. Humidity 1 1 Wet and dry bulb measurement technique Control Control loops Up to 8 On/Off single PID, Cascaded PID, Ratio Control or Override Control Control algorithms Linear, Water, Fan, Oil Control outputs Up to 2 Analogue, Time Proportioned or Motorised Valve control with or without feedback potentiometer No. of PID sets 3 Auto/manual control y Bumpless transfer or forced manual output available. Setpoint rate limit Each loop Ramp in units per sec. per minimum or per hour. Motorised valve control y Vp bounded and unbounded Tuning y One-shot Auto tune or Manual Loop alarms 4 per PID High absolute, Low absolute, Deviation high, Deviation low, block Deviation band, Rate of change. All with separate hysteresis Communications Modbus y y y Jumper selectable 2 or 4 wire RS485, 2 x RJ45 Profibus - DPv1 y y y High speed RS485. Up to 12Mb/s, 9 pin D-type connector or 2 x RJ45 Ethernet (Modbus TCP) y y y DeviceNet y y y Configuration itools Windows 2000, XP, (4.0): Minimum recommended platform Eurotherm: International sales and service Understanding and providing local support is a key part of Eurotherm's business. Complementing worldwide Eurotherm offices are a whole range of partners and a comprehensive technical support team to ensure you get a service you will want to go back to. AUSTRALIA Sydney Eurotherm Pty. Ltd. T (+61 2) 9838 0099 F (+61 2) 9838 9288 E info.au@eurotherm.com AUSTRIA Vienna Eurotherm GmbH T (+43 1) 7987601 F (+43 1) 7987605 E info.at@eurotherm.com BELGIUM & LUXEMBURG Moha Eurotherm S.A/N.V. T (+32) 85 274080 F (+32) 85 274081 E info.be@eurotherm.com BRAZIL Campinas-SP Eurotherm Ltda. T (+5519) 3707 5333 F (+5519) 3707 5345 E info.br@eurotherm.com DENMARK Copenhagen Eurotherm Danmark AS T (+45 70) 234670 F (+45 70) 234660 E info.dk@eurotherm.com FINLAND Abo Eurotherm Finland T (+358) 22506030 F (+358) 22503201 E info.fi@eurotherm.com Copyright Eurotherm Limited 2006 FRANCE Lyon Eurotherm Automation SA T (+33 478) 664500 F (+33 478) 352490 E info.fr@eurotherm.com GERMANY Limburg Eurotherm Deutschland GmbH T (+49 6431) 2980 F (+49 6431) 298119 E info.de@eurotherm.com HONG KONG & CHINA Eurotherm Limited North Point T (+85 2) 28733826 F (+85 2) 28700148 E info.hk@eurotherm.com Guangzhou Office T (+86 20) 8755 5099 F (+86 20) 8755 5831 E info.cn@eurotherm.com Beijing Office T (+86 10) 6567 8506 F (+86 10) 6567 8509 E info.cn@eurotherm.com Shanghai Office T (+86 21) 6145 1188 F (+86 21) 6145 1187 E info.cn@eurotherm.com INDIA Chennai Eurotherm India Limited T (+91 44) 24961129 F (+91 44) 24961831 E info.in@eurotherm.com IRELAND Dublin Eurotherm Ireland Limited T (+353 1) 4691800 F (+353 1) 4691300 E info.ie@eurotherm.com ITALY Como Eurotherm S.r.l T (+39 31) 975111 F (+39 31) 977512 E info.it@eurotherm.com KOREA Seoul Eurotherm Korea Limited T (+82 31) 2738507 F (+82 31) 2738508 E info.kr@eurotherm.com NETHERLANDS Alphen a/d Rijn Eurotherm B.V. T (+31 172) 411752 F (+31 172) 417260 E info.nl@eurotherm.com NORWAY Oslo Eurotherm A/S T (+47 67) 592170 F (+47 67) 118301 E info.no@eurotherm.com POLAND Katowice Invensys Eurotherm Sp z o.o. T (+48 32) 2185100 F (+48 32) 2177171 E info.pl@eurotherm.com SPAIN Madrid Eurotherm España SA T (+34 91) 6616001 F (+34 91) 6619093 E info.es@eurotherm.com SWEDEN Malmo Eurotherm AB T (+46 40) 384500 F (+46 40) 384545 E info.se@eurotherm.com SWITZERLAND Freienbach Eurotherm Produkte (Schweiz) AG T (+41 55) 4154400 F (+41 55) 4154415 E info.ch@eurotherm.com UNITED KINGDOM Worthing Eurotherm Limited T (+44 1903) 268500 F (+44 1903) 265982 E info.uk@eurotherm.com www.eurotherm.co.uk U.S.A. Leesburg VA Eurotherm Inc. T (+1 703) 443 0000 F (+1 703) 669 1300 E info.us@eurotherm.com www.eurotherm.com ED51 Invensys, Eurotherm, the Eurotherm logo, Chessell, EurothermSuite, Mini8, Eycon and Wonderware are trademarks of Invensys plc, its subsidiaries and affiliates. All other brands may be trademarks of their respective owners. All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it be stored in a retrieval system other than for the purpose to act as an aid in operating the equipment to which the document relates, without the prior written permission of Eurotherm limited. Eurotherm Limited pursues a policy of continuous development and product improvement. The specifications in this document may therefore be changed without notice. The information in this document is given in good faith, but is intended for guidance only. Eurotherm Limited will accept no responsibility for any losses arising from errors in this document. Part No. HA026430 Issue 3 Printed in England 08.06