SEISMIC VELOCITY TRANSDUCER T1-40



Similar documents
T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Instructions for Safe Use

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Box. Specifications TNCN

Explosion proof enclosures

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive sensor NI10-M18-Y1X-H1141

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. Dimensions

Terminal Boxes Series 8146

Series 8146/5-V37 and Series 8150/5-V37

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Operating Instructions

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

and Accelerometers

Flow switches Series AD/VH

Velomitor Piezo-velocity Sensor

Floodlight Range Installation Guide

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Control and Distribution Boxes made of Stainless Steel Series 8150

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

2.12. page Products for Explosion hazardous Environment

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Low Frequency Velocity Sensor

How To Use A Flowmeter

Proximity Transmitters and Seismic Vibration Transmitters

Technical data sheet TDS0070

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Inductive slot sensor

Compact pressure switch Flameproof enclosure Ex d Model PCA

S300 Series Dust Monitors

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Threaded Resistance Thermometers Model TR10-D, Miniature Design

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

3500/40M Proximitor* Monitor

Givare NC-SRS 280 och 880

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Flameproof Audible Signal 115 db (A) Series YA90

3500/62 Process Variable Monitor

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

Mounting Instructions. Torque Transducer. A en

Plastic tube flowmeters Series PT/PS

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

David O Brien, CMP Products (David.OBrien@cmp-products.com)

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

3/2-way Solenoid Valve, direct-acting, NC or NO

Non-contact Displacement Vibration TRANSDUCER

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Operating Instructions

CAPACITIVE LEVEL METERS CLM 36

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Differential-Hall-Effect based Sensors Series A5S

Technical Information RIA14

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

FGM 160 ATEX EC type examination certificate

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

SMS 4 / SMS 5 safety mat Product information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

3500/25 Enhanced Keyphasor*Module

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Guide to enclosures for potentially explosive atmospheres

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

3DLevelScanner II TECHNICAL DATA SHEET

Operating Instructions

Accessories SUNNY REMOTE CONTROL

A good connection. International approvals.

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

ZS25 Screw Clamp Terminal Blocks Feed-through

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Current Monitoring Kit QUICK START GUIDE

CompactLogix Power Supplies Specifications

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Current Monitoring Kit

Cable Plug acc. to DIN EN , Form A

TEIP11 I/P signal converter for standard signals. Measurement made easy

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Transcription:

SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute vibrations of the machinery through direct fixing (omnidirectional) on the supports of the vibrating part in a dangerous area. It supplies an output signal directly proportional to the vibration speed of the point to which it is fastened. Such signal is then processed in a safe zone by a measuring channel of the T series. The transducer, in its various models, is certified for applications in areas classified as: ZONE 0 ZONE 1 - Ex II 1GD Ex ia IIC T6 Ex iad 20 T85 C - Ex II 2GD Ex ia IIC T6 Ex iad 21 T85 C - Ex II 1GD Ex ia IIC T5 Ex iad 20 T100 C - Ex II 2GD Ex ia IIC T5 Ex iad 21 T100 C - Ex II 1GD Ex ia IIC T4 Ex iad 20 T135 C - Ex II 2GD Ex ia IIC T4 Ex iad 21 T135 C PRINCIPLE OF OPERATION A voltage, proportional to the speed of vibration, is induced in a coil suspended seismically to the transducer body and immersed in a field generated by a permanent magnet rigidly fastened to the transducer body.

SPECIFICATIONS Type of measurement : SEISMIC (absolute vibrations) Field of application : AMPLITUDE = ± 1000 µm p.p. FREQUENCY = 10 1000 Hz DIRECT. OF VIBR. = ANY Rated sensitivity : 21,2 mv/mm/sec (RMS) a 25 C Typical frequency : 12 Hz Damping coeff. : 0.7 Cross sensitivity : < 7% Output impedance : 1 Kohm at 25 C Power supply Ambient operating range External connections : None : Temperature = see certification Humidity = 100% max Ambient = IP65 EN 60529/10.91 : Connector MS/MIL-C-5015 series 3102/16, std. accessory Outer casing material : Alluminium P.Al.Si 5.5 (Zone 1) or Stainless steel AISI 303 (Zone 0) Weight of transducer Fastening Maintenance Enclosed drawings : approx. 0.300 kg : Screw, M8x1.25 L=16 mm : None : 17951 = Overall dimensions, layout and el. connections. TRANSDUCER POSITIONING Refer to drawing 17951. N.B.: The operations should be performed possibly with the machine stationary and taking the greatest care so as not to damage the internal mechanisms of the transducer. 1) On the support to be measured, drill a hole M8x1.25, 17 mm min. depth, making sure of its perpendicularity (if it is not possible to reach the depth of 17 mm, provide spacers of suitable thickness between the support surface and the transducer). The surface on which the transducer rests should be flat and smooth. It is advisable to apply a layer of silicone between the casing and the resting surface. 2) Screw the transducer in the M8x1.25 hole provided at point 1. Avoid knocks on the transducer. The use of a thread compound is advisable during tightening. 3) Carry out the electrical connections of the transducer to the measuring instrument by using the free lead connector (supplied as standard). Notes regarding positioning: - The wiring MUST be made with cables resistant to agents related to the workplace (oils, corrosive acids, temperature, etc.). - Shielded cables MUST be used. Make sure that the shield is connected to the frame earth (GND=ground) at just one of the cable ends (the instrument side is advised). - The electrical conductors must all have a minimum cross section of 1.0 mm², max. possible cross section = 2.5 mm² for a max. distance of approx. 800 metres. T1-40-ATEX 04 gb 2

Notes concerning certification: 1) The use of ATEX certified transducers is not allowed for different hazardous conditions or for those exceeding the data specified on the nameplate affixed to the transducer. 2) The transducer does not require maintenance. Any work regarding performance checks or repair should only be carried out in a laboratory duly authorized by CEMB SpA. Notes for the identification : The TRANSDUCER is manufactured in various versions in order to be correctly used according to : 1) the dangerous Zones where they will be used (zone 0 and 1) 2) the operating temperature (ambient t. and maximum t.) 3) the ambient operating characteristics (suitable or less suitable atmospheres for the following materials :, ALUMINIUM, ) These characteristics must match in order to meet ALL the plant requirements. The CEMB codes with which the main versions are identified and which meet requirements as per points 1 to 3 are as follows: CEMB Code ZONE 0 9801145T4 TRANSDUCER T1-40/00/00/1C (-40 +100 C) II 1GD Ex ia IIC T4 Ex iad 20 T135 C +135 C SURFACE, Zone 0, ATEX 9801145T5 TRANSDUCER T1-40/00/00/1B (-40 +80 C) II 1GD Ex ia IIC T5 Ex iad 20 T100 C +100 C SURFACE, Zone 0, ATEX 9801145T6 TRANSDUCER T1-40/00/00/1A (-40 +60 C) II 1GD Ex ia IIC T6 Ex iad 20 T85 C +85 C SURFACE, Zone 0, ATEX CEMB Code ZONE 1 9831145T4 TRANSDUCER T1-40/00/00/1N (-40 +100 C) II 2GD Ex ia IIC T4 Ex iad 21 T135 C +135 C SURFACE, Zone1,ATEX 9831145T5 TRANSDUCER T1-40/00/00/1M (-40 +80 C) II 2GD Ex ia IIC T5 Ex iad 21 T100 C +100 C SURFACE, Zone1,ATEX 9831145T6 TRANSDUCER T1-40/00/00/1L (-40 +60 C) II 2GD Ex ia IIC T6 Ex iad 21 T85 C +85 C SURFACE, Zone 1,ATEX T1-40-ATEX 04 gb 3

Information complete table D T1-40 / 00 / 00 / Example of order Where D = T1-40/00/00/1A 1A = Certif. Atex II 1GD Ex ia IIC T6 Ex iad 20 T85 C FOR ZONE 0, WITH CONNECTOR AND BODY D : Certification Code D Code BODY CONNECTOR MARKING /1A /1B /1C /1D /1E /1F ALUMINIUM ALUMINIUM ALUMINIUM II 1GD Ex ia IIC T6 Ex iad 20 T85 C II 1GD Ex ia IIC T5 Ex iad 20 T100 C II 1GD Ex ia IIC T4 Ex iad 20 T135 C II 2GD Ex ia IIC T6 Ex iad 21 T85 C II 2GD Ex ia IIC T5 Ex iad 21 T100 C II 2GD Ex ia IIC T4 Ex iad 21 T135 C /1G ALUMINIUM II 2GD Ex ia IIC T6 Ex iad 21 T85 C /1H ALUMINIUM II 2GD Ex ia IIC T5 Ex iad 21 T100 C /1I ALUMINIUM II 2GD Ex ia IIC T4 Ex iad 21 T135 C /1L ALUMINIUM ALUMINIUM II 2GD Ex ia IIC T6 Ex iad 21 T85 C /1M ALUMINIUM ALUMINIUM II 2GD Ex ia IIC T5 Ex iad 21 T100 C /1N ALUMINIUM ALUMINIUM II 2GD Ex ia IIC T4 Ex iad 21 T135 C /1P /1Q /1R II 2GD Ex ia IIC T6 Ex iad 21 T85 C II 2GD Ex ia IIC T5 Ex iad 21 T100 C II 2GD Ex ia IIC T4 Ex iad 21 T135 C T1-40-ATEX 04 gb 4

Certifications according to ATEX 94/9/CE 0722 II 1GD Ex ia IIC T6 Ex iad 20 T85 C 0722 II 1GD Ex ia IIC T5 Ex iad 20 T100 C 0722 II 1GD Ex ia IIC T4 Ex iad 20 T135 C 0722 II 2GD Ex ia IIC T6 Ex iad 21 T85 C 0722 II 2GD Ex ia IIC T5 Ex iad 21 T100 C 0722 II 2GD Ex ia IIC T4 Ex iad 21 T135 C CESI 01 ATEX 050 Legend of nameplate safety data Marking of compliance with the applicable European directives 0722 Number of the Notified Body carrying out the surveillance (CESI) II 1GD / II 2GD Marking of compliance with 94/9/CE Directive and relevant technical standards II 1 GD Equipment intended for use in areas in which Ex atmosphere caused by gases and dust, suitable for Zone 0 and 20 II 2 GD Equipment intended for use in areas in which Ex atmosphere caused by gases and dust, suitable for Zone 1 and 21 Not suitable for mines Ex ia II C T6-T5-T4 Equipment belonging to category "ia" with intrinsic safety Suitable for substances (gas) of group IIC, also suitable for groups IIA and IIB T6 temperature class (surface temperature: 85 C) T5 temperature class (surface temperature: 100 C) T4 temperature class (surface temperature: 135 C) Ex iad T85 C Ex iad T100 C Ex iad T135 C T. amb. CESI 01 ATEX 050 Protection for Dust For T6 class, ambient temperature : -40 60 C For T5 class, ambient temperature : -40 80 C For T4 class, ambient temperature: -40 100 C Certificate identification : Name of the laboratory issuing the CE-type-examination certificate 01 = year of certificate issue 050 = certificate number T1-40-ATEX 04 gb 5

ASTD90420 T1-40-ATEX 04 gb 6