How To Configure An African Atlas



Similar documents
Configuring the ADTRAN ATLAS for a Rabbit-Hole Application

An ADTRAN White Paper. Integrating LAN Fax Servers over T1 and PRI Services

First, we must set the Local Dialing Type to 7 or 10 digits. To do this, begin by clicking on Dial Plan under Voice.

Imecom White Paper. T1/PRI Configuration for the Imecom DM Fax Server with Brooktrout TR1034 Digital Fax Board(s)

Automatic Routing of Inbound Faxes With Castelle Network Fax Servers. Fractional T1, Full T1, Fractional E1, Full E1, ISDN, DID and PBX Integration

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

Automatic Routing of Inbound Faxes with Open Text Network Fax Servers

Optimum Business SIP Trunk Set-up Guide

PBX to PBX VoIP network (H.323)

BroadCloud Adtran Total Access Quick Start Guide

Digital Trunks. Objectives. When you finish this module, you will: Understand the different types of digital trunks.

Vega 100G and Vega 200G Gamma Config Guide

Application Notes for Multi-Tech FaxFinder IP with Avaya IP Office Issue 1.0

COMPLEX SYSTEMS ONE SOLUTION

AudioCodes Mediant 1000 Configuration Guide

SIP Trunking using Optimum Business SIP Trunk Adaptor and ShoreTel IP PBX Phone System

Quick Installation Guide

Mediatrix 4404 Step by Step Configuration Guide June 22, 2011

NetVanta 7060/7100 Configuration Checklist

Initial configuration Vega 400 E1/T1 (H.323) Gatekeeper Mode R7

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

3CX PBX v12.5. SIP Trunking using the Optimum Business Sip Trunk Adaptor and the 3CX PBX v12.5

Avaya IP Office SIP Trunk Configuration Guide

Bulk Downloader. Call Recording: Bulk Downloader

Application Notes for Configuring Wesley Clover Solutions Trading Platform with Avaya IP Office using SIP Trunks Issue 1.0

VegaStream PSTN Gateways and pbxnsip

24/48 Channel T-1 / PRI Logger. Installation Guide

Using Cisco UC320W with Windows Small Business Server

SIP Trunking using the Optimum Business SIP Trunk adaptor and the AltiGen Max1000 IP PBX version 6.7

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Panasonic KX-NCP500 IP PBX V2.0502

Application Notes for the Vocera Communications System with an Avaya IP Telephony Infrastructure - Issue 1.0

SIP Trunk Configuration Guide. using

Link Gate SIP. (Firmware version 1.20)

Allo PRI Gateway and Elastix Server

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Allworx 6x IP PBX

Enabling NAT and Routing in DGW v2.0 June 6, 2012

Application Notes for MultiTech FaxFinder IP with Avaya IP Office Issue 1.0

Integrating Citrix EasyCall Gateway with SwyxWare

Analog IP Gateway GXW410x Quick Installation Guide SW version

Converged Voice Service Summary

Mediatrix 3000 with Asterisk June 22, 2011

Digium Switchvox AA65 PBX Configuration

IPPBX FAQ. For Firmware Version: V2.0/V

IP Office - Job Aid Remote Access

Remote Annex. Quick Start for Windows. Read before installing and using Remote Annex Software Release 4.2

Windows 98 Workstation Install

Inbound Routing with NetSatisFAXTion

How To Set Up Ops Cser.Com (Pros) For A Pc Or Mac) With A Microsoft Powerbook (Proos) (Prosecco) (Powerbook) (Pros) And Powerbook.Com/

Victoria Combo Remote Control

IP PBX. SD Card Slot. FXO Ports. PBX WAN port. FXO Ports LED, RED means online

Authenticating a Lucent Portmaster 3 with Microsoft IAS and Active Directory

User Manual for the OPERA E1/T1 Option OPR-002-E1T-P

T1 Networking Made Easy

Upgrade your Software

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Enhanced ANI/DNIS Substitution in AOS

SMB8000 Interactive Voice Response INSTALLATION AND SETUP MANUAL

Configuration guide for Switchvox and Cbeyond.

ScopTEL TM IP PBX Software. Managing Incoming Lines

Setup Reference guide

Internet Telephony Terminology

Application Notes for Configuring Cablevision Optimum Voice SIP Trunking with Avaya IP Office - Issue 1.1

ESI SIP Trunking Installation Guide

Application Notes for Configuring SIP Trunking between Metaswitch MetaSphere CFS and Avaya IP Office Issue 1.0

eircom advantage VoIP Netwrorking Configuration Guide

For T1 / E1, an NT NeTwork device must be connected to a TE Terminal Equipment device; NT must connect to TE.

NEC 2400 IMS --- T1 PRI

QUICKSTART GUIDE FOR CDI CELLULAR STARTER KIT

Alti-Mobile Extensions

ISDN Troubleshooting October 11, 2012

MITEL SX3300 AX Controller w/ NSU or Internal T1 Card

Updating MNS-BB CUSTOMER SUPPORT INFORMATION PK012906

SBC 1000 / SBC 2000 Series Configuration Guide (For Microsoft Lync Server 2013)

INTRODUCTION 3 XYZ EXAMPLE 3 CONNECTING THE FAXFINDER TO THE IP OFFICE SWITCH 4 CONFIGURING THE FAXFINDER FOR INTER-OPERATION -- THE XYZ EXAMPLE 4

Integrated Voice. Service Guide. Save money and maximize bandwidth efficiency Version

CCRecord Professional SIP Trunk Recording. Application Notes

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Cisco Call Manager Express Version 8.5

ACTi NVR Config Converter User s Manual. Version /06/07

Configuration Guide for connecting the Eircom Advantage 4800/1500/1200 PBXs to the Eircom SIP Voice platform.

Abstract. Avaya Solution & Interoperability Test Lab

Fonality. Optimum Business Trunking and the Fonality Trixbox Pro IP PBX Standard Edition V p13 Configuration Guide

Configuration BCP Skype for Business

SIPSTATION User Guide. Schmooze Com Inc.

Dialogic Vision VG Media Gateway

Initial configuration Vega 400 E1/T1 (SIP)

FaxFinder. V.34 Fax Server. Configuration Guide for Inter-Operation between FaxFinder Model FF110 and 3Com NBX PBX Systems

Reference Guide for Inter-Operation with Avaya IP Office INTRODUCTION 3 XYZ EXAMPLE 3 CONNECTING THE FAXFINDER TO THE IP OFFICE SWITCH 4

FAQs on ETERNITY ME/GE/PE. 2. I have connected Analog line to the TWT port of ETERNITY, but line is not working. Why?

Application Note Startup Tool - Getting Started Guide

Configuration Notes 283

T3 Mux M13 Multiplexer

Opera VoIP Networking Configuration Guide

MAX Communication Server Release 7.5

Configuring SIP Trunking and Networking for the NetVanta 7000 Series

P160S SIP Phone Quick User Guide

Skype Connect Getting Started Guide

Extend the Life of Your Legacy PBX while Benefiting from SIP Trunks. December 5, 2013

Installation and setup guide V 1.0

Atlas Event Logging Explanation

Transcription:

Configuring the ATLAS for a Primary Rate ISDN (PRI) to T1 Robbed Bit Signaling (RBS) Conversion Introduction The ADTRAN ATLAS 550/800/800 PLUS supports both Primary Rate ISDN (PRI) and T1 Robbed Bit Signaling (RBS) services. PRI provides up to 23 bearer (B) channels and one signaling channel (D channel). The ATLAS T1/PRI interface uses a standard RJ-48C connector. T1 connections provide up to 24 DS0 channels and use the RBS scheme to pass call signaling status information. ATLAS can be used to connect PRI circuits to Customer Premise Equipment (CPE) such as PBXs, Key Systems, Video Conferencing Systems, or FAX servers, that only have T1 interfaces or require costly upgrades for PRI connections. In switching applications, the ATLAS uses a simple configuration scheme known as the Dial Plan. There are two parts to the Dial Plan: Network Term and User Term. Typically, the Network Term will be the service line provided by the telco or the line that interfaces with the public network. The User Term is most often the interface used to connect other customer premise equipment to the ATLAS. Before You Begin Before you begin configuration of the ADTRAN ATLAS, you need some basic information. 1. Information needed from the PRI service provider: a. Switch Type of the PRI line (Ex: National ISDN, DMS-100, 5ESS, or 4ESS) b. Number of B channels in service and on which DS0s the B-channels reside c. Phone number(s) assigned to the PRI line d. Number of digits being provided 2. Information needed from the end user/customer: a. Signaling Type(s) supported by the end user equipment (Loop Start, Ground Start, E&M Wink, E&M Immediate, or Feature Group D). If using Feature Group D, Tone Type is also needed. b. Actual phone numbers to be used on the PBX or other equipment (in the range of the PRI numbers). c. Number of digits to be transferred to the end user equipment.

Configuration of the ATLAS To create the network shown in Figure 1, configure the PRI side of the network in the Network Term portion of the Dial Plan. Then, configure the T1 side of the network in the User Term portion. The procedures for both steps are found on the following page. Configuring the PRI Figure 1 The PRI is configured in the Network Term portion of the Dial Plan. The Network Term configuration consists of the following fields: 1. Out # Accept 2. Out # Rej 3. Signaling 4. Ifce Config o Switch Type o First DS0 o Number of DS0s NOTE: This is not a complete list of the Ifce Config features. For simplicity, any field not mentioned in this document remains in the default state. 1. Out # Accept -- typically '$', which represents 'all calls'. This feature can be used to restrict outbound calls. All calls meeting the criteria entered in this field are allowed to pass through. For example, an entry of 'N$' allows only local calls to be sent out the PRI. (A full description of N, X, and [ ] number entry characters are available while in this field by pressing Ctrl A) 2. Out Number Reject -- normally left blank. This feature can also be used to restrict outbound calls. In contrast to the Accept List, the Reject List blocks all calls meeting the criteria entered in this field. For example, an entry of '1$' blocks all long distance calls on the PRI. 3. Signaling - For this application, signaling should be PRI.

4. Interface Configuration -- contains provisioning information of the PRI given by the service provider. Figure 1 shows the switch type to be National ISDN, and the number of active B channels as 23, which signifies a full PRI. This would be configured as follows: a. Switch Type: National ISDN b. First DS0: 1 c. Number of DS0s: 23 Figures 2 and 3 display the setup of the Network Term and Interface Configuration respectively. Figure 2

Figure 3 NOTE: The ATLAS automatically uses channel 24 as the D channel. The D channel may not be provided on any other DS0. Configuring the T1 The T1 is configured in the User Term portion of the Dial Plan. The User Term configuration consists of the following fields: 1. In # Accept 2. Out # Rej 3. Signaling 4. Infce Config o First DS0 o Number of DS0s o Signaling Method o Direct Inward Dialing NOTE: This is not a complete list of the Ifce Config features. For simplicity, any field not mentioned in this document remains as default. The Network Term (Figure 4) and Ifce Config (Figure 5) are included for this example configuration.

1. In # Accept -- represents the phone numbers associated with the T1 DS0s. Remember that the telco provides these numbers on the PRI. Calls coming into the ATLAS matching the In # Accept list are routed to this port. For example, if all calls to phone numbers 963-1000 through 963-1099 should be routed to the T1 on Sys Ctrl, Port 2 (0.2), the In # Accept list for 0.2 will contain the entry 963-10XX. 2. Out Number Reject List -- typically left blank. This feature can also be used to restrict outbound calls. In contrast to the Accept List, the Reject List blocks all calls meeting the criteria entered in this field. For example, an entry of '1$' blocks all long distance calls going out the PRI. 3. Signaling - Signaling for the T1 User Term is RBS 4. Interface Configuration -- contains user defined provisioning information for the T1. The user-defined information is local to the ATLAS and the end user equipment. Do not contact your telco for this information; this is completely independent of the PRI provisioning. a. First DS0 - For most cases this will be the first DS0 or 1. If fewer than 23 B Channels are provided on the PRI or some are used for data, this setting may vary to suit the configuration of the T1 end-user equipment. b. Number of DS0s - Normally 23 corresponding to a full PRI, but may be less as previously described. The ATLAS will also permit overbooking to 24 DS0s, additional T1's, or to Basic Rate Interfaces all with the understanding that only 23 calls can go out through the network PRI at one time. c. Signaling Method - The signaling method is set for the option corresponding to the method used on the T1 end-user equipment. Ground Start, Loop Start, E&M Wink, and E&M Immediate provide signaling options for most equipment. The Feature Group D selection is used with PBX or similar equipment specially designed for this ANSI standard. When using Feature Group D, a Global Tone Type setting for DTMF or MF tones (default is DTMF) must be set under the Dial Plan. Note: The Global Tone Type setting affects all trunks. d. Direct Inward Dial - DID is enabled to allow presentation of digits to the user equipment. The number of digits sent are selected in the DID Digits Transferred field. This is normally set to the number of incoming digits provided by the telco, such as 7.

Figure 4 Figure 5

Sample Configuration Files The sample configuration files (see below) are examples of the application described in this note. These files may not contain all the configuration options needed for your specific application and are not meant to be used as a working configuration for a live network. WARNING: Loading these sample configuration files will overwrite any existing configuration on your ATLAS product. NOTE: Prior to loading a configuration file to the ATLAS, disengage any modules currently installed in the ATLAS. The configuration file may contain modules configured in certain slots which conflicts with modules installed in your ATLAS. If a configuration file is loaded onto an ATLAS in which the configured modules do conflict with installed modules, then the portion of the configuration relating to those modules ports will not be loaded. Download the configuration 1. Download the appropriate configuration file in the right-hand pane of this webpage under Attachments according to which ATLAS product you have. ATLAS 550 ATLAS 800 ATLAS 800PLUS ATLAS 810PLUS p_r550.cfg p_r800.cfg p_r800p.cfg p_r810p.cfg NOTE: If you don t see the right-hand pane click the Show Info button in the top right hand portion of this webpage. 2. Refer to the following section entitled Loading a Configuration File to an ATLAS Base Unit for full instructions on downloading the configuration file to the ATLAS unit. Loading a Configuration File to an ATLAS Base Unit TFTP downloads require Ethernet connectivity between the ATLAS 10BaseT port and a PC or workstation running TFTP server software. Note that a Windows-based TFTP server is included as a part of ADTRAN Utilities which comes with each ATLAS base unit.

1. Launch the TFTP Server on the PC being used to connect to the ATLAS by going to Start, Programs, ADTRAN Utilities, TFTP Server. Note the server's IP Address that is displayed. 2. Establish a telnet session between the PC and the ATLAS. (Telnet is provided with Windows or ADTRAN Utilities). 3. Select the System Utility menu then press <Enter> on the Config Transfer option. 4. In the TFTP Server IP Address field, enter the IP address of the TFTP server which was noted in step 1. 5. In the TFTP Server Filename field, enter the file name of the configuration file. This.CFG file should be located in the ADTNUTIL folder on the PC's hard drive. NOTE: If the file name of the configuration file is incorrect or the file is not located in the ADTNUTIL folder, then the Config Transfer will fail. 6. Press <Enter> on the Load And Use Config to begin the transfer. The current configuration of the ATLAS will now be overwritten with the contents of this new configuration file. The ATLAS will perform a quick reboot once the transfer is complete.