Calibration Service Selection Guide



Similar documents
Calibration Certificate

CRM s and the Dilemma of the 2nd Source. Shawn Kassner, Sr Product Manager Tim Miller, Sr Organic Chemist Phenova, A Phenomenex Company

Procedure for Equipment Calibration and Maintenance

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

calibrate confidence with Metrology Concepts: Understanding Test Uncertainty Ratio (TUR) Abstract Introduction White Paper

Estimates of Uncertainty of the Calibration of Balances

THERMAL INSULATION MATERIALS

Process Measurement Assurance Program For U.S. State Metrology Laboratories 1

Weight Calibration ComparatorPac TM Simple Calibration Efficient Workflow Reliable Results

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

OPERATIONAL STANDARD

ALACC Frequently Asked Questions (FAQs)

Laboratory Metrology Education and Training. Georgia L. Harris NCSLI VP Learning and Development NIST Weights & Measures Division

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

Standard Practice for Quality Control Systems for Nondestructive Testing Agencies 1

How DCMA Helps To Ensure Good Measurements

Measuring equipment in a laboratory.

Supplier Quality Assurance Requirements Manual

Certificate of Calibration No

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

ISO and SANAS guidelines for use of reference materials and PT scheme participation Shadrack Phophi

LAB14 EDITION 4 November 2006

NVLAP Assessor Training

How To Test For A Quality Management System

VERIFYING CALIBRATION OF WEIGHING DEVICES USED FOR LABORATORY TESTING

Software Verification and Validation

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

Balance Calibration A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance

OIML D 18 DOCUMENT. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Enhanced calibration High quality services from your global instrumentation partner

Performance and advantages of qnmr measurements

PRODUCT GUIDE PRECISION INSTRUMENTS FOR Temperature, Density, Time, Weather and Calibration

QUALITY MANUAL GREAT LAKES INSTITUTE FOR ENVIRONMENTAL RESEARCH ANALYTICAL LABORATORIES. October 2008 Revision 08

NVLAP Assessor Training. Assessor Qualification & Training Requirements

EVALUATION AND ACCREDITATION OF SUPPLIER TEST FACILITIES GP 10

BQ-9000 Quality Management System. Certified Marketer Requirements

ISO Accreditation for a Standing Start Finish (SSF) Primary Flow Stand with Coriolis Flowmeters as Reference Standards.

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

NIST HANDBOOK CHECKLIST CONSTRUCTION MATERIALS TESTING

DRAFT CLAM. Laboratory Accreditation Manual (CLAM) Acme Construction Company Artesia Laboratory 1234 Bulldog Street Championship, CA 90210

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

Quality Management System Policy Manual

User checks and maintenance of laboratory balances

Rules for the certification of Quality Management Systems

Environment-Laboratory Ambient Conditions

EffiValidation 3.0 software basic training module

TITLE: Quality System Manual DOCUMENT NUMBER: QMS

ISO/IEC ACCREDITATION REQUIREMENTS FOR CALIBRATION LABORATORIES

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

calibrate confidence with Risk Management: The Critical Role of Measurement and Calibration WHITE PAPER SERVICES

Calibration Solutions. be certain.

EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT

Testing Your Laboratory Balance

Luminus Devices, Inc Luminus Testing Laboratory Quality Management Systems Manual

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

1 For more information T: / E: DAP@ul.com / W: ul.com/dap

International Laboratory Accreditation Cooperation. Laboratory Accreditation or ISO 9001 Certification? global trust. Testing Calibration Inspection

Measuring instruments in industry.

RTP s NUCLEAR QUALITY ASSURANCE PROGRAM

EPO No. 16. Appendix A. Description of Test Methods

ISO/IEC QUALITY MANUAL

Non-Controlled Copy. Quality Manual Revision Log. Rev # Date Description

CALIBRATION DATA MANAGEMENT: MEETING THE REPORTING REQUIREMENTS OF ISO/IEC FDIS

Calibration method for conductivity cells

COPY. Revision History: Changes were made to reflect the current practice of only including the most recent changes in the revision history.

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

NORSOK STANDARD M-650 Edition 4. Qualification of manufacturers of special materials

Testing Facility Laboratory Manual

State Laboratory Program Workload Survey

CALIBRATION PRINCIPLES

SUPPLIER Form #: 007 AUDIT QUESTIONNAIRE

Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Gravimetric determination of pipette errors

and Drug Administration/Office of Regulatory Affairs (FDA/ORA) laboratories.

R103 - GENERAL REQUIREMENTS: PROFICIENCY TESTING FOR ISO/IEC LABORATORIES

Lab Service, Asset Management and Extending the Life of Your Lab Equipment. Scott Greenwood Director, Services

The Unique Accelabar Flow Meter

Technical Notes NDT 001 Specific Requirements for Non- Destructive Testing Laboratories

Model 601A02. Low-cost Industrial ICP Accelerometer. Installation and Operating Manual

Validation and Calibration. Definitions and Terminology

Observations on the determination of gold in gold alloys cupellation method (Fire Assay)

Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications

Regulatory Requirements for Medical Device Calibration Programs

EPA NATIONAL LEAD LABORATORY ACCREDITATION PROGRAM. LABORATORY QUALITY SYSTEM REQUIREMENTS (LQSR) REVISION 3.0 (November 05, 2007)

American Association for Laboratory Accreditation

NRMCA Quality Certification. Ready Mixed Concrete Quality Management System. Certification Criteria Document

Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less

Open Vulnerability and Assessment Language (OVAL ) Validation Program Test Requirements (DRAFT)

Conductivity Sensor Calibrations to Meet Water Industry Requirements

Measurement Canada. Presentation to Ontario Smart Grid Working Group. Who is Measurement Canada?

Surgi Manufacturing Quality Manual

Quality Assurance Manual January 2008 Revision I Revision date of 01/17/13. Pi Tape Corporation. 344 North Vinewood St. Escondido CA USA

Product Liability Risk Control Checklist

Transcription:

Calibration Service Selection Guide Certification of Accreditation available for download at www.ricelake.com/accreditation. Answer Questions to determine the calibration service you need Need accredited* laboratory certificate to meet ISO/ IEC 70 and ANSI/NCSC Z40- requirements? YES NO What Weight Class? ASTM 0,,, ; OIML E, E, F, or F ASTM 4,, 6, 7; NIST F; OIML M, M, M Traceability to NIST? YES NO Calibration Weight classes: ASTM 0, OIML E, E, F, F Meets all the requirements of the National Voluntary Laboratory Accreditation Program (NVLAP) Provides traceability to NIST Meets requirements for ISO/IEC 70 and ANSI/NCSL Z40- Lists the environmental conditions present at time of calibration cites that the test was done by RLWS, an accredited laboratory states that RLWS is ISO 900 registered Traceable Weight classes: ASTM 4 7, NIST F, OIML M, M, M Meets all the requirements of the National Voluntary Laboratory Accreditation Program (NVLAP) Provides traceability to NIST Meets requirements for ISO/IEC 70 and ANS/ NCSL 40- Lists the environmental conditions present at time of calibration cites that the test was done by RLWS, an accredited laboratory states that RLWS is ISO 900 registered RLWS Mass Value Weight classes: ASTM, OIML, F, F Uncertainty to tolerance ratios are not guaranteed to be met Lists actual weight values, uncertainties, and tolerances Measurements are traceable to NIST Not an accredited certificate Statement of Accuracy (Only applicable to new weights) This is not a Legal for Trade or traceable document Does not give traceability to NIST All weight classes Tolerance statement of the weight Nominal value of the weight is listed Tolerance for the specific weight class is noted Before, after or uncertainties values are not listed 4 * Accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for the specific scope of accreditation under Lab Code 000-0.

Documentation Traceable vs. Calibration The major difference between the two is the method in which the weights are compared to the known standard. They both give the actual values and uncertainties. The Calibration will, however, give a smaller uncertainty and a more precise value of the actual mass due to the multiple measurements that are made during the calibrating process. Both the Traceable and Calibration will include the following information: Actual mass values or the corrections to the nominal mass of the weight being calibrated vs. 8 grams/cm. The uncertainty of the measurement process as it relates to the item being calibrated. The environmental conditions present during the test. The assumed density of the weight being tested so that atmospheric buoyancy corrections can be applied. Which Document Do I Need? This is one of the most frequently asked questions we hear at our Mass Metrology Laboratory and often times, the decision has already been made for you depending on the class of weight being evaluated. Sometimes the answer is obvious, as when a company has legal or contractual requirements that mandate a specific document. Government contracts may dictate a document to meet certain Military Standard specifications. Often the need for quality control requirements for ISO-9000 guidelines specify that certain standards be met in their weight documentation. In the absence of any programs or guidelines within your company, the Accuracy Classes for Mass Standards and Test Weights chart on page 4 can be used as a guide to define whether a Calibration or Traceable is required. A Statement of Accuracy is adequate if the actual values and stated uncertainties of the weights are not necessary, and only the tolerances of the specific class are needed. These documents are normally adequate for weights used to calibrate industrial balances and scales more than 6 kg in capacity. The mass standards used by Rice Lake Weighing Systems are used to verify that those weights are within the necessary tolerances. Weights with this document do not meet the requirements needed in Legal for Trade scale applications. Legal for Trade Weight Applications NIST Class F weights are required for all Legal for Trade applications which include any product that is sold by weight. This would include all retail scales and floor and truck scales. For these applications we recommend a traceable certificate, which will give actual values and uncertainties of the weights. Most State Weights and Measures Departments require this information as a minimum to allow weights to be put into field service. This is usually the same information that the state gives when they certify weights. Check with your state and local Weights and Measures Department for acceptance of our documentation.

Calibration A customer requesting a Calibration needing traceability to NIST is looking for actual weight readings, corrections and uncertainty values. To produce this document, a calibration laboratory must maintain a statistical measurement process acceptable by NIST. Also, depending on the weight class and the accuracy required, different standards and procedures need to be incorporated to make sure the level of uncertainty is appropriate for the item being tested. The Weight Calibration is in compliance with ISO International Standard 70 and ANSI/NCSL Z40- requirements. The special software used to produce the Calibration was developed specifically for Rice Lake Weighing Systems. These programs and procedures allow Rice Lake Weighing Systems to achieve and help maintain lower uncertainties. The Calibration includes the following information: Name and address of` the calibration laboratory Contractor name and address Client name and address 4 Environmental condition at time of test Your Traceable number 6 NIST number 7 Mass Dissemination 8 Identification of the calibrated item and serial number, if applicable 9 Nominal mass value 9 0 7 4 7 8 0 8 6 4 6 0 As found condition of the weight before adjustment As left condition of the weight A statement of the estimated value of uncertainty Tolerance for the specific class 4 Record of the weighing equipment Calibration and due date of RLWS standards. This represents the date that RLWS standard is due for recalibration. This RLWS standard was used to check the performance of your weight. This date in no way reflects an expiration date of the certificate, nor does it infer or specify a recall date. The expiration of the certificate and the specification of a recall date are user assigned responsibilities under NIST H0-. 6 Assumed density of the weight being tested 7 Date Calibrated 8 Recall Date 9 The NVLAP official logo will be displayed when the documentation meets the scope of accreditation under Lab Code 000 9 Mass Dissemination using NIST SOP, NIST SOP 8 0 Conventional Mass - mass that weight weighs at 0 C in air of density of. mg/cm against a standared density of 8.0 g/cm. Refer to page 4 for Calibration Service Selection Guide. A reported value without all required parameters cannot be used in any link of traceability. Therefore, a calibration certificate without an uncertainty statement is useless. 6

Traceable A customer requesting a Traceable needs proof of traceability to NIST, actual mass values and uncertainties. Comparisons must be made between the item being tested and a known standard being used. The laboratory performing the testing must verify that the proper procedures and standards are being used so that the uncertainties are suitable for the test that is required. The known standard and procedure used for the tolerance test is essential to the traceable document. The Traceable is in compliance with ISO International Standard 70 and ANSI/NCSL 40- requirements. Prior to the comparison between the known standard and the item(s) submitted for test, the known standard must be sufficiently tested over time to produce predictable measurements. Also, the procedure used to do the comparison must be accurate enough so the uncertainty of the measurement is small enough to generate a valid certificate. This certificate should contain all of the data related to the tolerance test. After testing, a Traceable is issued and will include: Name and address of` the calibration laboratory Contractor name and address Client name and address 4 Environmental condition at time of test 7 Your Traceable number 4 6 NIST number 7 Modified Substitution 8 Identification of the calibrated item and serial number, if applicable 7 8 9 0 8 0 6 4 6 9 Nominal mass value 0 As found condition of the weight before adjustment As left condition of the weight A statement of the estimated value of uncertainty Tolerance for the specific class 4 Record of the weighing equipment Calibration and due date of RLWS standards. This represents the date that RLWS standard is due for recalibration. This RLWS standard was used to check the performance of your weight. This date in no way reflects an expiration date of the certificate, nor does it infer or specify a recall date. The expiration of the certificate and the specification of a recall date are user assigned responsibilities under NIST H0-. 6 Assumed density of the weight being tested 7 Date Calibrated 8 Recall Date 9 The NVLAP official logo will be displayed when the documentation meets the scope of accreditation under Lab Code 000 9 Modified Substitution using NIST SOP 8, RLWS Work Instruction W0-00 0 Conventional Mass - mass that weight weighs at 0 C in air of density of. mg/cm against a standared density of 8.0 g/cm. A reported value without all required parameters cannot be used in any link of traceability. Therefore, a traceable certificate without an uncertainty statement is useless. 7

RLWS Traceable Mass Value A customer requesting a RLWS Traceable Mass Value, needs proof of traceability to NIST and actual values and uncertainties. Comparisons must be made between the item being tested and the standard being used. The known standard used for the tolerance test is essential to the traceable document. Prior to comparison between the known standard and the item submitted for testing, the known standard must be sufficiently tested over time to produce predictable measurements. This certificate should contain all of the data related to the test. After testing, a RLWS Traceable Mass Value is issued. Although the RLWS Traceable Mass Value provides traceability to NIST, it is not a NVLAP accredited document. If an accredited document is required, please refer to the TMAP Traceable and/or TMAP Calibration. The RLWS Traceable Mass Value includes the following information: Name and address of` the calibration laboratory Contractor name and address Client name and address 4 Environmental condition at time of test Your Traceable number 6 NIST number 7 Modified Substitution 8 Identification of the calibrated item and serial number, if applicable 9 Nominal mass value 9 0 7 4 7 8 0 6 4 6 0 As found condition of the weight before adjustment As left condition of the weight A statement of the estimated value of uncertainty Tolerance for the specific class 4 Record of the weighing equipment Calibration and due date of RLWS standards. This represents the date that RLWS standard is due for recalibration. This RLWS standard was used to check the performance of your weight. This date in no way reflects an expiration date of the certificate, nor does it infer or specify a recall date. The expiration of the certificate and the specification of a recall date are user assigned responsibilities under NIST H0-. 6 Assumed density of the weight being tested 7 Date Calibrated 0 Conventional Mass - mass that weight weighs at 0 C in air of density of. mg/cm against a standard density of 8.0 g/cm. Modified Substitution using NIST SOP 8, RLWS Work Instruction W0-00 A reported value without all required parameters cannot be used in any link of traceability. Therefore, a traceable certificate without an uncertainty statement is useless. 8

Statement of Accuracy* A customer requesting a Statement of Accuracy, needs proof that the nominal values represented by the mass in question have been designed and manufactured to within exact specifications. The Statement of Accuracy provides just such a document when and where traceability to NIST, and/or the need for a NVLAP accredited document is not a concern. The Statement of Accuracy is the lowest level of documentation offered by Rice Lake Weighing Systems. Check with your internal procedures and policies to determine what type of documentation you require and thoroughly review the RLWS Traceable Mass Value, Traceable, and Calibration options prior to selecting this laboratory documentation. The Statement of Accuracy includes the following information: Name and address of` the company that adjusted the weights Part number Description/Serial number 4 Tolerance for the specific class Name and address of company that items were sold to 6 Name and address of company that items are shipped to *Only applicable to new weights. Not a Legal for Trade or traceable document. 6 4 9

Rice Lake Selection Guide RICE LAKE CERTIFICATE SELECTION GUIDE Item on 70:00 and ANSI/NCSL Z- 40- Accredited Name and address of calibration laboratory NVLAP Calibration NVLAP Traceable RLWS Mass Value of Accuracy YES YES NO NO YES YES YES YES Contractor (sold to) name and address * Client (ship to) name and address * YES YES YES YES YES YES YES YES 4 The Traceable Report number of the for the item under test YES YES YES NO Environmental conditions at time of test YES YES YES NO 6 NIST number YES YES YES NO 7 Procedure used YES YES YES NO 8 Identification of the Item(s) and serial number (if applicable) YES YES YES YES 9 Nominal mass value YES YES YES NO 0 As found value of item under test YES YES YES NO As left value of item under test YES YES YES NO Estimated uncertainty of the measurement YES YES YES NO The tolerance for the specified class YES YES YES YES 4 Equipment number for the mass comparator/ Balance used to perform the test YES YES YES NO The standards used to calibrate the item under testand the date the standard was calibrated by RLWS and date due for recalibration YES YES YES NO 6 Assumed density of the item(s) YES YES YES YES 7 Legal For Trade document NIST Class F NO NO 8 True mass values Available upon request NO NO NO 9 Book form certificate (long form certificate) Available upon request NO NO NO 0 Disclaimers * Can be specified by customer or client Required for satin finish weights certified to ASTM Class A reported value with a stated uncertainty is required for Traceability. Required for cast iron grip handle and slotted weights smaller than kg to ASTM Class 6 Required for satin finish weights certified to ASTM Class NO 40

Rice Lake Selection Guide (continued) RICE LAKE CERTIFICATE SELECTION GUIDE Weight Class Accredited to 70:00 and ANSI/NCSL Z40- NVLAP Calibration Accredited to 70:00 and ANSI/NCSL Z40- NVLAP Traceable Non-Accredited RLWS Mass Value Non Accredited and NOT LEGAL FOR TRADE of Accuracy ASTM 0 YES - - YES ASTM YES ** - YES ** YES ASTM YES - YES YES ASTM YES - YES YES ASTM 4 - YES - YES ASTM - YES - YES ASTM 6 - YES ** - YES ASTM 7 - YES - YES OIML E YES - - YES OIML F YES - YES YES OIML F YES - YES YES OIML M - YES - YES OIML M - YES - YES OIML M - YES - YES NIST F - YES - YES NIST M - obs - - YES - NIST S - obs YES * - YES ** - NIST S- - obs YES ** - YES - NIST P - obs - - YES - NIST T - obs - YES - - NIST C - obs - YES - - ** Satin finish weights require a disclaimer because the surface finish of satin finish weights do not meet the requirements of.7. and Table 6 of the ASTM E 67- standard *** Cast iron weights kg or Less require a disclaimer because they do not meet the requirement for density listed in.6 and Table of the ASTM E 67- standard Only applicable to new weights Uncertainty to tolerance ratios are not guaranteed to be met 4