Designed for multi-injector endurance testing, the



Similar documents
ECOCIAT. Domestic hot water heat recovery unit

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Diagram of components 2. Reducer..3

MP-4000 Alarm List (Software version or later)

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HVAC Processes. Lecture 7

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Ammonia Detection System Codes and Design Specifications

Hydraulic Control Solutions

Cooling Channel Optimization

ORGANIC SAMPLE PREPARATION

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

*.ppt 11/2/ :48 PM 1

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Wynn s Extended Care

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Cat Electronic Technician 2015C v1.0 Product Status Report 2/20/2016 4:34 PM

API Marine. BMS Presentation. Ballast Measurement Systems

E - THEORY/OPERATION

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Smile. The All-In-One Heating Controller

TMS TANK MANAGEMENT SYSTEM

Process Alarm Solutions

PARAGON ELECTRIC, INC. LIQUID LEVEL CONTROLLER USER MANUAL MODELS: LLC-I, LLC-II AND TELEMETRY OPTIONS

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

Signature and ISX CM870 Electronics

KNC Model 3666 Automatic Pressure Calibration System

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Heating, air-conditioning, cooling

T-100-R Installation Guide

Air conditioning service unit CAAS500

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

HERZ-Thermal Actuators

Oil and Coolant Circulating Heating System. Model - OCSM

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Carbon Tech Series GS8 GS4 GS2. GASOLINE injector equipment. The only way to test Gasoline Direct injectors. 300 Bars+


Hydraulic Trouble Shooting

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Make A Fronius Cl Power Inverter

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Permissible ambient temperature Operation Storage, transport

DTC Database (OBD-II Trouble Codes)

Marine Generating Sets 3.7 to 50 kva

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Cat Electronic Technician 2015C v1.0 Product Status Report 2/16/2016 9:19 AM

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Pure Efficiency. C.C.I.A.A.: N REA Cod. Fiscale e P. IVA: Capitale Sociale versato ,00

CNC MILLING MACHINE TROUBLE SHOOTING. 1. Trouble Shooting. No Trouble Solution. 1.Check the air pressure

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Computer Controlled Nozzle Performance Test Unit, with SCADA TFTC

GPD 506/P5 Start-up Procedure and Checklist

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Evaporative emissions system

REGTRONIC OPERATING INSTRUCTIONS

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Ces deux analyseurs permettent le contrôle de la qualité de l eau et des effluents.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

ON-Board Diagnostic Trouble Codes

Overheating limit control

ELECTRIC CENTRAL HEATING FLOW BOILER

HCE80/HCC80/HCE80R/HCC80R

Phase Modular Finally the benefits of Modular ups are for all

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Specifications KN

Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1

PowerGem Pro Uninterruptible Power Supply

Rotary screw compressors kw 5,5 7, , bar MODULO

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Photovoltaic Solar Energy Unit EESFB

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Material test chamber with mechanical convection

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

RRV934. Multi-controller. Synco living

SUSPENSION AND STEERING OVERVIEW

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

Signature and ISX CM870 Fuel System

Product overview Air conditioning service units

Magnum Mobile Generator MMG55 Specifications

Transcription:

Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures to establish accelerated aging cycles that reproduce the life of a vehicle. Test program cycling can be automated and results are measured and stored for engineering review. EFS distributed bench control delivers dedicated, dynamic control response with stability. But just as important, EFS test bench architecture delivers builtin diagnostics and monitoring connections to increase up-time and peace of mind. ETB Endurance Test Bench

Composition ETB - Instrumentation table (1800 mm x 1000 mm) - One EFS 250 cm 3 rail and 3 motor rails - Cooling system with heat exchanger (air / water) - High pressure management system comprising a drive motor and a high pressure pump - Extractable hydraulics drawer for ease of maintenance - Holding tank of 40 liters fitted with a level indicator, drain valve and handle for easy removal - Environmental security tank of 100 liters with level sensor - Cabinet comprising various safety alarms and interlock control - Air extraction vent 2 Composition

Benefits Bench for up to 12 injectors, simultaneously Touchscreen Software parameter setting with dedicated diagnostics and front panel status: rail pressure, tank temperature, coil or piezo timing control, test cycles... Flexible, wide range control of coil or piezo injector drive (IPoDs) Flexible, wide range control of the rail pump (HPC) Safety monitoring of the pump and rail (HPC) Equipment test up to 2200 bars (standard), opt. high pressure pump available. 3

Descriptive Each injector is fitted with pressure and temperature sensors to monitor the evolution of leak or return flow to determine durability state. Clamping of the injector Various nozzles can be tested by simply fixing adaptations and circuit connections. 4 Descriptive

High pressure rail EFS A main rail capacity of 250 cm 3 accumulates the test fluid at high pressure to feed the sub-rail configuration of actual vehicle operation. Max pressure: 3000 bar Length: 350 mm Diameter: 150 mm Connections HP pump inlet Three outputs to vehicule rails Pressure transmitter Safety valve Rupture disc 2500B DESP 97/23 IV Standard reference sensor Two inputs / outputs reserve. High pressure The high pressure pump is controlled by the HPC - a dedicated controller providing fast, tight control and safety monitoring. Software setup provides flexible control for any pump. Pressure: 2000 bar (higher option) Fixed speed: 3000 rpm Direction of rotation: anti-clockwise. 5

Descriptive Chassis - Type: 8689 - Dimensions (mm): 1590 x 1000 x 1800 Low pressure The oil supply to the bench is provided by a low pressure pump motor. 6 The 40 l primary tank supplies the low pressure pump with 3 µm filtered fluid. The pressure can be adjusted via an overflow. The circuit low pressure feeds the high pressure pump. Descriptive

Cabinet Integral to the side of the bench, it includes the following elements: Soft starter, HP pump brake and booster pump, Security and safety modules, PLC Power supply module, Relays, fuses... Electrical characteristics Type: 3P + N + E Voltage: 400 V Frequency: 50 /60 Hz Power: 23 kva Hydraulics drawer The hydraulic drawer is located at the front of the bench, and comprises: Primary tank of 40 liters for supplying the oil to the injection pump, Control of feeding pressure, Temperature regulation of the test fluid (oil / water), and A precise filtering of the test fluid. This tank is equipped with security features (level sensors, temperature sensor, safety valve and thermostat). 7

Security Safety and interlock devices Starting the test only after locking the cover Control of the drive motors (soft start) Double checks at primary tank: - Temperature of the test fluid (temperature sensor and thermostat) - Fluid level test: two level sensors (critical and security) Check the pressure sensor and mechanical components of the high pressure rail (safety valve and breaking disc) Two emergency stop buttons (punch) Extraction of hydrocarbon vapors. This bench is equipped with an interlocking keyed system to protect against incorrect locking and unlocking. Monitoring primary tray Monitoring the temperature of the test fluid contained in the primary tank is ensured by the automatic bench. Temperature sensor allows for regulation Two level sensors 8 A 70 C pre-set thermostat prohibits exceeding this temperature in this tray (bench stopped). Security

Emergency stop The test bench is equipped with two emergency stop buttons: on the bench and on the measurement cabinet. A controller monitors the main functions of the test bench automatically and continuously. In the event of a detected fault on a device, it initiate an emergency stop. Interlock system The cover is made of aluminum profile with a polycarbonate window. Security is managed by the PLC. Opening allowed only if the pressure is below the minimum pressure (P < Pmin) set in the HPC. Opening allowed only if the nozzle outlet temperature (measured by a PT100 sensor) is less than 50 C. 9

Software Separate from the bench operating environment control, the ETB Bench supervisory software precisely and reliably configures and queues endurance cycles that are controlled through the fast responding, dedicated distributed controllers and the injector drive controller. The ETB Supervisory software also provides system monitoring of injectors under test. Measurement cabinet Measurement cabinet includes: Industrial PC on which the software is installed (cycle management and data archiving) Rail high pressure controller EFS 8549 (HPC) Injector drive power modules (solenoid or piezo, multi-injector) Diagnostics and buffered, isolated monitoring signals for drive and rail pressure control 24 VDC supply Security elements (light column signal, circuit breaker, disconnector...) 10 An inverter. Software

test mode... is the primary use mode of the bench providing configuration, starting and stopping. functions Access to functions using touch keys Display of up to 12 measurement channels Display of pressure and temperature setpoints in the high pressure rail Display of pressure and temperature measurements in the high pressure rail Display of pressure and temperature measurements for each channel. 11

setting mode This mode allows you to program a new cycle and / or modify certain parameters of the cycle. 12 functions Display of parameters of the current cycle Display of pressure in the rail, tank temperature, drive signal, pump control, etc. Program a new cycle and / or modify certain parameters of the cycle. Software

maintenance mode This mode allows unit testing of equipment or functions to facilitate maintenance. functions Ability to enable/disable an injector drive while continuing overall endurance test, Control of the pump... 13

Specifications ELECTRICAL CHARACTERISTICS Type Voltage Frequency Power Maximum current Short-circuit current WATER COOLING Maximum inlet pressure Maximum outlet pressure Input /output min differential pressure Maximum flow consumed 1 bar delta P (flow coefficient) Water temperature (max) 3P + N + E 400 V 50/60 Hz 23 kva 33.5 A 10 ka 5 bar 1 bar 3 bar Kv = 10 l/mn 10 C Water network connection (input and return) 1/2 CIRCUIT TEMPERATURE CONTROL Water / oil exchanger 310 W/ C TANKS Primary tank 40 liters Recovery tank 40 liters Environmental security tank 100 liters FILTERS Primary tray filter 60 µm Oil filter 3 µm Water filter 10 µm VENTILATION Outer diameter 115 mm Recommended suction flow 120 m 3 /h 14 Specifications

References ETB 15 Reference

SITE ADDRESS 192 Allée des Chênes Parc d activité du Baconnet 69700 MONTAGNY FRANCE TELEPHONE & E-MAIL Tel.: +33 (0)4 72 49 27 72 Fax: +33 (0)4 72 49 27 77 e-mail: sales_inj_eng@efs.fr Website: www.injection.efs.fr ACCESS MAP SUBSIDIARY IN CHINA providing technical support - installation, training, maintenance and calibration. 16 Brochure BANC ENDURANCE V4.0-2-06-2014 fr-en