System monitoring case studies



Similar documents
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

How to set up EARTH FAULT ALARM On Fronius inverters

Solar-Bau Elisabeth Str Gorlitz 056/651/25124 USt-IdNr: DE

Fronius Datalogger Web

Transformerless PV inverter withstandardsystem monitoring. Fronius IG TL

TOTAL RECALL MAX Potential Connection Diagrams CALL RECORDING. Product Specifications YOU NEED TOTAL RECALL MAX

How To Make A Fronius Cl Power Inverter

IAdea GPIO Extender Application Note

Executive Summary. Technical Description

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Setting Up the ZigBee Ethernet Gateway

Voice Over Internet Protocol (VoIP) Configuration

The technical aspects of V90 or V92 on two analogue telephone lines (both side PSTN) or a so called a point to point connections.

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

IT S HARD TO MAKE THINGS EASY.

DoorKing IM Server TM

Figure 1: RotemNet Main Screen

BRI to PRI Connection Using Data Over Voice

NEW. Solar-Log & GE Meter Residential Solar PV Monitoring & Metering Built into a Single Device

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

Networking. Introduction. Types of Wireless Networks. A Build-It-Ourselves Guide to Wireless Mesh Networks

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

MIDNITE SOLAR AND SOLAR WASHINGTON

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

System Requirements. Package Contents

PM1122 INT DIGITAL INTERFACE REMOTE

Sunny Boy SB 700. String Inverter 700 W, grid-tied operation, grid frequency 777,00 50 Hz / 60 Hz auto-detection SB 1100LV

computer radio control system

SCADA and Monitoring for Solar Energy Plant

What is Bitdefender BOX?

Data-logger evaluation software GSoft V2.8

RHINO TRACKS STANDARD GPS VEHICLE TRACKER

How to connect your Victron to a computer with VE Bus Quick Configure

Experiment # 6 Remote Access Services

Smart Telephone System

VIESMANN. Data communication Vitocom, Vitodata, Vitosoft, Vitogate. Technical guide. TeleControl. ServiceControl. Building automation

NortechCommander Software Operating Manual MAN R6

/ / / Audio distribution system A44/A88 pc software

rs-ba1 remote control software quick reference guide

BLACK BOX Scalable matrix KVM switch supports up to 1024 ports with fiber or copper cable.

PARADISE DATACOM APPLICATION NOTE CONTROL AND MONITOR OF DISTANT END TERMINAL USING LOCAL MODEM WEB USER INTERFACE EVO_AN_001

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

SCDSB Video Conferencing

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

SMS GSM Alarm Messenger

Internet Guide. Prepared for 55 John Street

s!nus-elektrotechnikai bt. Industrial IT & Automation

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

Communication Setup Application Note

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

Connecting instruments serially to your computer

Function Description Device Management in Ascom Systems

USB GSM 3G modem RMS-U-GSM-3G. Manual (PDF) Version 1.0,

Engineering and service software For KNX and LPB plants

Why WireFree: Wireless Gas Detection System Basics and Benefits

UDG1000 Hach PCX2200 Serial Port Input Driver configuration

Ecotech Air Quality Monitoring Data Acquisition System

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Huawei E169 & E220 Status Lights

GSM Interfacing Board

Softalk Share Server Quick Start Guide Micro-business scenario

SNMP-1 Configuration Guide

INTRODUCTION 3 XYZ EXAMPLE 3 CONNECTING THE FAXFINDER TO THE IP OFFICE SWITCH 4 CONFIGURING THE FAXFINDER FOR INTER-OPERATION -- THE XYZ EXAMPLE 4

Opera VoIP Networking Configuration Guide

INTERNET CONNECTIVITY

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Aeroqual Connect and Cloud

Unidirectional Transmitter/ Receiver Units Introduction

IXP120 Alarm Monitor Utility

optipoint 500 system telephones The new telephone family for HiPath/Hicom systems

Serial Cables & Adapters

Accessing Diagnostics using a Dialup Modem

Eaton Remote Monitoring Manual

User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720

Vodafone Mobile Broadband via the phone

Technical Support Information

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

SETTING UP A REMOTE MODEM CONNECTION Application Note 27


802.11n Wireless Broadband Router WNRT-625

Software Registration and the DoorKing IM Server Internet Modem (IM) Server Program Summary

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

HDCATS-100. Installation Guide

GUANGZHOU SANJING ELECTRIC CO., LTD

OSM 2007 MONITORING SOFTWARE

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SNMP Web Management. User s Manual For SNMP Web Card/Box

NEW. EVEN MORE data acquisition and test stand automation

ESP 20/20. Compressor Monitoring System

Access control designed simply for you

Transcription:

System monitoring case studies 4,5 kwp system, detached house internet display 1 9 kwp system, detached house remote monitoring, sensors, radio display 3 14 kwp system, farm radio display, fault reporting contact 5 40 kwp system, public participation system internet display, remote monitoring, large-scale display, sensors 7 80 kwp system, private rooftop installation string monitoring, remote monitoring 9 Sketch diagram of initial configuration for remote monitoring of system 11

Sketch diagram for case study 1 Basic configuration with modem, as recommended by Fronius PC / laptop Fronius IG.access Datalogger easy Card RS 232 (up to 20m) Tixi modem (analog) RS 232 Telephone line Internet Server FRONIUS SolarWeb Internet 1

4,5 kwp system, detached house Example 1 On-site situation: 4,5 KWp system 1 Fronius IG Plus 50 Inverter is installed in the cellar. Distance between inverter and PC: 10m No sensors Analog telephone Recommended setup: Fronius IG.access (user) No remote monitoring Internet display FRONIUS SolarWeb Step 1 (datalogger) Only 1 inverter, distance from PC < 20 m 1 Fronius IG Datalogger easy Card Step 2 (components) Table shows: In addition to the datalogger, Fronius IG.access requires: 1 Fronius IG FRONIUS SolarWeb also requires: 1 Tixi MessageModem 56 k Step 3-7 not required Summary: 1 Fronius IG Datalogger easy Card (Fronius IG.access software included) 1 Fronius IG 1 Tixi MessageModem 56 k Cables required: The RS 232 cable for connecting the datalogger card to the PC must be made up to the correct length. Instructions for the once-only procedure to configure the modem can be found on the last page. Since the customer has an analog telephone system, the 56 k Tixi MessageModem is selected

Sketch diagram for case study 2 Basic configuration with modem, as recommended by Fronius System operator PC / laptop Fronius IG.access Datalogger profi Box USB Tixi modem ISDN RS 232 FAX PC / laptop FRONIUS IG.access Personal Display Card Personal Display Card Fax Service max 20m Installation engineer Personal Display Sensors max 30m Sensor box (up to 6 sensors) 3

9 kwp system, detached house Example 2 On-site situation: Recommended setup: 9 KWp system 2 Fronius IG Plus 50 Inverters are installed in the cellar. Distance between inverters and PC: 30m ISDN telephone system Insolation sensor and module temperature sensor Fronius IG.access (user) Personal Display Warning message sent to installation engineer by fax (via Tixi MessageModem) Step 1 (datalogger) 2 inverters, distance from PC > 20 m 1 Fronius IG Datalogger profi Box The datalogger is installed near the PC as it is connected to a USB port. Step 2 (components) Table shows: In addition to the Datalogger, Fronius IG.access requires: 2 Fronius IG s Also required for the warning message: 1 ISDN Tixi MessageModem with fax function The installation engineer can now make a choice: Either he can enable faults to be sent to him by fax direct from the modem. Alternatively, he can set up Fronius IG.message in his office and enable automatic fax forwarding. In our example, the engineer has decided to receive notification by fax direct from the Tixi MessageModem. For servicing purposes the engineer can also use Fronius IG.access to monitor the system from his office. All the components required for this are already installed. Step 3 (sensors) The insolation sensor and the temperature sensor are installed on the roof. The inverters are installed in the cellar. The distance from the inverters to the sensors is 20 m. When the distance from the inverters to the sensors is > 15 m Fronius IG Sensor Box Step 4, 5 and 7 are not required Step 6 (Personal Display) The Personal Display is set up in the living room. One Personal Display card (with its own antenna) is installed for each inverter. 1 Fronius IG Personal Display 2 Fronius IG Personal Display Card Summary: 1 Fronius IG Datalogger profi Box (Fronius IG.access software included) 2 Fronius IG 1 ISDN Tixi MessageModem with fax function 1 Fronius IG Personal Display 2 Fronius IG Personal Display Card 1 Fronius IG Sensor Box (plus: insolation sensor and temperature sensor) Cables required: cable for connecting Datalogger Box to inverter (self-assembly, or install a ready-made CAT 5 cable) cable for connecting Sensor Box to inverter (self-assembly, or install a ready-made CAT 5 cable) cable for connecting inverter to inverter (self-assembly, or install a ready-made CAT 5 cable) USB cable for connecting Datalogger Box to PC RS 232 cable for connecting inverter to modem (included with modem) POTS cable for connecting modem to telephone (included with modem) Instructions for the once-only procedure to configure the modem can be found on the last page.

Sketch diagram for case study 3 Personal Display Card Signal Card Personal Display Card Signal Card Personal Display Card Signal Card Personal Display 5

14 kwp system, farm Example 3 On-site situation: 14 kwp system 3 Fronius IG Plus 50 Inverters are installed on the outside of the barn. The distance from the house is 100 m Recommended setup: Data transfer via radio link Fronius IG Personal Display Floating fault reporting contact Fronius IG Signal Card Step 1 5 are not required Step 6 (radio display) The radio display is positioned in the living area in the house. One Personal Display card (with its own antenna) is required for each inverter. The following components are required to transfer data by radio: 1 Fronius IG Personal Display 3 Fronius IG Personal Display Cards Step 7 (floating fault reporting contact) One Fronius IG Signal Card is required for each inverter. Summary: 3 Fronius IG Signal Cards (plus optionally: 1 optical or acoustic signal transmitter) 1 Fronius IG Personal Display 3 Fronius IG Personal Display Cards Cables required: none

Sketch diagram for case study 4 Datalogger profi Card Sensor Card RS 232 Tixi modem (analog) POTS cable Internet Server FRONIUS SolarWeb Telephone line Public Display PC / laptop Installation engineer Fronius IG.access Service e-mail PC / laptop Operating company Fronius IG.access Internet Sensor 7

40 kwp system, public participation system in a school Example 4 On-site situation: 40 kwp system 3 Fronius IG Plus 150 Inverters are installed on the roof Distance from telephone connection: 10 m (one floor below) Recommended setup: Internet display FRONIUS SolarWeb Fully-automated energy comparison Fronius IG.access Service contract with installation engineer Service E-Mail via modem Insolation and temperature sensor Fronius IG Public Display Step 1 (datalogger) 3 inverters, distance from PC < 20 m 1 Fronius IG Datalogger profi Card Step 2 (components) Table shows: In addition to the datalogger, Fronius IG.access (fully-automated energy comparison) requires: 3 Fronius IG s To enable service e-mails to be sent out (service contract with installation engineer) you will also need: 1 Tixi Message Modem For FRONIUS SolarWeb (internet display) no additional components are required other than the modem, which is in any case needed for sending service e-mails. Step 3 (sensors) The insolation sensor and temperature sensor are installed alongside the inverters on the roof. Distance from inverters to sensors < 15 m 1 Fronius IG Sensor Card Step 4 (FRONIUS IG Public Display) The large display is located in the school's entrance area. Also required in addition to the datalogger and s: 1 Fronius IG Public Display Step 5, 6 and 7 are not required Summary: 1 Fronius IG Datalogger profi Card incl. Fronius IG.access software incl. 2 termination plugs 3 Fronius IG s 1 Tixi Message Modem 1 Fronius IG Sensor Card (plus: insolation sensor and temperature sensor) 1 Fronius IG Public Display Cables required: cable for connecting inverter inverter (must be made up to length, or a ready-made CAT 5 cable can be used) cable for connecting inverter Public Display (must be made up to length, or a ready-made CAT 5 cable can be used) RS 232 cable for connecting inverter to modem (included with modem) POTS cable for connecting modem to telephone (included with modem) Instructions for the once-only procedure to configure the modem can be found on the last page.

Sketch diagram for case study 5 Fronius IG 500 Fronius IG 500 FRONIUS String Control FRONIUS String Control integrated integrated Datalogger profi Box USB PC or laptop user 9

80 kwp system, private rooftop installation Example 5 On-site situation: 80 kwp system 2 Fronius IG 500 with s already included Distance between inverter and user PC: 50m Recommended setup: System monitored by user Fronius IG.access String monitoring FRONIUS String Control Step 1 (datalogger) 2 inverters, distance from inverter to PC > 20 m 1 Fronius IG Datalogger profi Box Step 2 (components) Table shows: In this scenario Fronius IG.access does not require any additional components other than the datalogger because every Fronius IG central inverter already has a. Step 3 and 4 are not required Step 5 string monitoring (FRONIUS String Control) s and a datalogger are pre-requisites for string monitoring. The following are also required 2 FRONIUS String Control Fuses for String Control Step 6 and 7 are not required Summary: 1 Fronius IG Datalogger profi Box incl. Fronius IG.access software incl. 2 termination plugs 2 Fronius IG s 2 FRONIUS String Control Fuses for String Control Cables required: cable for connecting inverter Datalogger Box (must be made up to length, or a ready-made CAT 5 cable can be used) cable for connecting inverter inverter (must be made up to length, or a ready-made CAT 5 cable can be used) USB cable for connecting datalogger to PC cable for connecting inverter String Control (must be made up to length, or a ready-made CAT 5 cable can be used) cable for connecting String Control String Control (must be made up to length, or a ready-made CAT 5 cable can be used)

Sketch diagram of initial configuration for remote monitoring of system Basic configuration To ensure the accurate interchange of data between the modem and datalogger the modem must be initialised once. To do this you should connect a PC or laptop to the datalogger on which the latest version of the Fronius IG.access software is installed. The menu choice "Settings" "Modem for datalogger" allows you to select and initialise the relevant modem. Datenlogger profi Card To configure the modem on a one-off basis you will require: RS 232 cable for connecting datalogger - PC (must be made up to length, or a ready-made interface cable* can be used) RS 232* (to next inverter) PC / Laptop RS 232 Modem * Please find the correct PIN-assignment in the operating manual Fronius IG DatCom 11