Farm Fuel Tank Safety Guide



Similar documents
ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

DOES YOUR COMPANY NEED AN SPCC PLAN? Larry Seabolt Remtech Engineers Remediation Specialists

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

Spill Prevention, Control and Countermeasure (SPCC) Rule

~CSRMA ALERT~ REVISED SPCC RULE WILL IMPACT MOST POTW S

Spill Prevention Control and Countermeasure (SPCC) Regulations Fact Sheet

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Spill Prevention, Control, and Countermeasures (SPCC) Course Material

OREGON FIRE CODE Interpretations and Technical Advisories


Spill Prevention, Control & Cleanup SC-11

Spill Prevention, Control, and Countermeasures (SPCC) Regulations Update

The following definitions apply with regard to requirements specified in this document:

The Comprehensive Environmental Response,

Steel Tank Institute AST Inspections. Dana Schmidt, PE STI/SPFA

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

The Comprehensive Environmental Response,

OIL STORAGE REQUIREMENTS OF THE SPCC REGULATIONS. Christopher J. Ecsedy, P.E. Fuss & O'Neill, Inc. 146 Hartford Road Manchester, CT 06040

Spill Prevention, Control and Countermeasure (SPCC) Training

TRAINING SPCC/SWPP Training UGA. Automotive Center. Campus Transit

Section 5. Secondary Containment and Impracticability. (as applicable to APSA tank facilities)

The following definitions apply with regard to requirements specified in this document:

Appendix VIII: Spill Prevention, Control and Countermeasure (SPCC) Plans

SPILL PREVENTION CONTROL AND COUNTERMEASURE PLAN PREPARED FOR: ARKANSAS STATE UNIVERSITY JONESBORO, ARKANSAS ORIGINAL DATE OF PLAN: APRIL 2005

Safe Operating Procedure

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Contact Person Sarah Morris-Benavides Revision 1.1 Document Plan Effective Date 07/01/2014 Review Date 03/15/2017.

Design of a Fuel Oil Storage Facility

TITLE 29: EMERGENCY SERVICES, DISASTERS, AND CIVIL DEFENSE CHAPTER I: EMERGENCY MANAGEMENT AGENCY SUBCHAPTER d: STATE EMERGENCY RESPONSE

Waste Oil Collection / Storage

FUELING AND FUEL STORAGE

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014

How To Safely Handle A Spill

History of the SPCC Rule

ABOVE-GROUND STORAGE TANKS

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

Environmental Health & Safety

Shop Fabricated Aboveground Tank Construction Standards

Critical Regulations SUMMARY OF. Stormwater Management Regulations (National Pollutant Discharge Elimination System or "NPDES ) 40 CFR 122.

Spill Control Prevention Plan (SCPP)

Spill Prevention Control and Countermeasure Plan

FACILITY ENVIRONMENTAL COMPLIANCE

The Fuel Storage Tank Regulations 2009

KANSAS STORAGE TANK PROGRAM ABOVEGROUND STORAGE TANK OVERVIEW March 2, 2015

Civil Engineering Sector Labour-Management Health and Safety Committee

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

UNIVERSITY OF WISCONSIN MADISON

OIL POLLUTION PREVENTION REGULATIONS

SPILL PREVENTION, CONTROL AND COUNTERMEASURE (SPCC) PLAN

SPCC for Food Services

TULANE UNIVERSITY SPILL PREVENTION CONTROL & COUNTERMEASURE (SPCC) PLAN FOR OIL STORAGE AREAS

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

Appendix N Framework Spill Prevention, Containment, and Countermeasures Plan Prepared by: Idaho Power Company 1221 W Idaho Street Boise, ID 83702

Kurt Wilson Louisiana Dept. of Environmental Quality Business & Community Outreach Division Small Business/Small Community Assistance Program

Natural Resources Conservation Authority Guidelines for Secondary Containment of Hazardous Liquids stored Above-ground

SPILL PREVENTION, CONTROL, AND COUNTER MEASURES PLAN (SPCC)

Pollution Liability Exposure: Adjustments your automotive business should consider to maintain compliance

Spill Prevention, Control and Countermeasures (SPCC) 40 CFR 112. For Bulk Facilities

Used Oil Guidance. Tank and Secondary Containment Requirements For Used Oil Processors

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

CHAPTER PETROLEUM CONTACT WATER

ALL UST SYSTEMS. MOTOR FUEL, USED OIL, BULK HEATING OIL STORAGE (Federal/State Regulated Systems)

MASSACHUSETTS INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMPUS SPILL PREVENTION, CONTROL, AND COUNTERMEASURE (SPCC) PLAN

Pollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN. for the PIÑON RIDGE MILL HIGHWAY 90 BEDROCK, COLORADO Prepared by:

Secondary Containment of Large Aboveground Storage Tanks

Outdoor Liquid Container Storage

Fuel Storage Who to ask: tank farm owners/operators

SOP 4: Spill Response and Cleanup Procedures SOP 4: SPILL RESPONSE AND CLEANUP PROCEDURES

UPDATE ON MAINE'S UNDERGROUND TANK LAWS

Secondary Containment Options for Aboveground and Underground Tanks. Wayne Geyer Steel Tank Institute

U. S. EPA REGION 8 OIL PROGRAM

Draft. ATLANTIC COAST PIPELINE, LLC ATLANTIC COAST PIPELINEINE Docket No. PF and

COMPLIANCE MANAGEMENT STRATEGIES. Presented by: Megan Kazmierczak, ECS Eclipse

APPENDIX O. Spill Prevention and Emergency Response Plan. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX O

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

Spill Prevention, Control and Countermeasure Plan (SPCC) Program

SPILL PREVENTION, CONTROL, AND COUNTERMEASURE (SPCC) REGULATION

Agenda Item 16 Compilation of States Above-Ground Storage Tank Programs and Regulations

MODULE IV Secondary Containment, Oil Spill Control & Spill Prediction

SPILL PREVENTION, CONTROL, & COUNTERMEASURE PLAN

Transcription:

Farm Fuel Tank Safety Guide This brochure is provided by North Dakota Department of Emergency Services, your Local Emergency Planning Committee, and the State Emergency Response Commission along with assistance from the ND Fire Marshal and the ND Department of Health.

In North Dakota, It s common practice for farms and ranches to have fuel storage tanks and containers. Almost every year, accidents happen that raise questions on safety issues and reporting requirements. The Farm Fuel Tank Safety Guide is designed to help farmers and ranchers understand what is required of them and how to protect lives, property, and the environment. Regulations SARA Title III (Public Law 99-499) More widely known as the Emergency Planning and Community Right-to-Know Act (EPCRA), Section 304 (a) and (b) state that if a release of an Extremely Hazardous Substance (EHS) or any substance subject to the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA), the owner or operator of a facility shall immediately provide notice (by telephone, radio, or in person) to the emergency coordinator for the Local Emergency Planning Committee (LEPC) and to the State Emergency Response Commission (SERC). Oil spills 25 gallons or less and cleaned up immediately need not be reported. SPCC Regulation 40 CFR 112 The Environmental Protection Agency s Spill Prevention Control and Countermeasures (SPCC) requirements must be complied with if both of the following conditions apply to your farm or ranch facility: 1. You own or operate a non-transportation related fixed facility that could reasonably be expected to discharge oil into or upon the navigable waters of the United States or adjoining shorelines. 2. Your facility has: A total above-ground storage capacity of more than 1,320 gallons (counting only containers with a capacity of 55 gallons or greater);

-or- A total underground buried storage capacity of more than 42,000 gallons, unless it meets all the Underground Storage Tank (UST) requirements (40 CFR 280-281) My facility qualifies. What should I do? All SPCC-regulated facilities must have oil spill containment structures to prevent oil spills and contaminated runoff from reaching storm drains, streams, ditches, rivers, and other navigable waters. See 40 CFR 112.7 for a list of possible containment systems. If you are the owner or operator of a SPCC farm or ranch, you must have a written site-specific spill prevention plan that details your facility s compliance with 40 CFR part 112. Requirements for specific elements to include the SPCC Plan are found in 40 CFR 112.7. Once your Plan is completed, a Registered Professional Engineer (PE) who is familiar with the SPCC requirements and has examined your facility must review and certify the Plan. Most importantly, you must fully implement the SPCC Plan. If your facility is newly constructed, contact the ND Department of Emergency Services haz-chem coordinator for information regarding plan submission and requirements for SPCC plans. Remember to consider All petroleum based oil stored on your farm or ranch, including oil used to lubricate machinery, maintain equipment, heat buildings, run irrigation pumps, fuel vehicles and heavy equipment may be subject to the regulation. Once you exceed one of the SPCC capacity requirements, you must manage all oil at your site to comply with the rule. State exemptions do not supersede the requirement to comply with the Federal Oil Pollution Prevention Regulation.

For more information contact the U.S. Environmental Protection Agency at 303-312-6839 or 303-312-6202. North Dakota Petroleum Tank Release Compensation Fund (PTRCF) The PTRCF financially assists tank owners for cleanup costs and third party liability caused by a leak or spill. Both underground and aboveground tanks are covered by the Fund. An owner must register all tanks and pay an annual fee of $50 for each tank prior to the discovery of a release. Farm and ranch underground tanks greater than 1100 gallons must be registered. Underground tanks less than 1100 gallons and all aboveground tanks are excluded if they are used for non-commercial purposes. Farmers and ranchers can voluntarily join the Fund upon application and payment of fees for excluded tanks. For more information contact the North Dakota Insurance Department at 701-328-9600. North Dakota Underground Storage Tank Program (UST) Farm and ranch underground petroleum tanks greater than 1.100 gallons must meet all the UST requirements of North Dakota Administrative Code Chapter 33-24-08, Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks. Owners/operators of existing or new tanks regulated under the UST Program are required to notify the UST Program and register their tanks. For assistance and information, contact the North Dakota Department of Health, Division of Waste Mangement, UST

Program at 701-328-5166. What do I do if I have a leak or spill? 1. Contain the spill and protect lives and property. 2. Contact emergency responders and the Local Emergency Planning Committee (LEPC). 3. All leaks and spills must be dealt with immediately. If you need immediate assistance, the Duty Officer will contact the ND Department of Health. For other assistance and information, contact the Department s Waste Management Division at 701-328-5166 during normal working hours. 4. Contact the ND Department of Emergency Services Duty Officer through State Radio at 1-800-472-2121 with the following information, if possible: Name or type of substance; Actions taken to contain the spill/leak; Estimated quantity released; Time and duration of release; Type of area affected (ground, water, wetlands, river, etc.); Noticeable health effects as a result of the spill/leak; and Your name and contact information. Who do I call for information about SPCC plans? Call the ND Department of Emergency Services haz-chem coordinator at 1-800-773-3259.

Fuel Tank Guidelines Tank Construction Tank Supports Piping Support and Protection Capacity Venting Tank Valves Fire Extinguisher Under 1,100 gallons (Use of good and sound engineering practices) Over 1,100 gallons (Refer to Underwriters Laboratory Standard 142) Tanks designed for underground use cannot be used aboveground Tanks over 1,100 gallons must be placed on firm ground or have supports of non-combustible construction (such as concrete) NO metal stands Pipe not buried underground must be protected from damage and supported to prevent stress on the pipe and cracking Pipe buried underground must be installed with leak protection 10,000 gallons per tank (MAX) Under 1,100 gallons (Normal Venting Required) Over 1,100 gallons (Normal and Emergency Venting Required) Under 1,100 gallons must have a manual shut-off valve as close to tank as practicable Over 1,100 gallons must have an internal or external fire valve, manual shut-off valve and solenoid valve for a remote dispenser Minimum of one rated at 40 BC recommended; Located as close as practicable

Fuel Tank Guidelines Spill Control Under 1,100 gallons has no requirement Over 1,100 gallons must have protection usually in the form of a dike of liquid-tight material such as earth, clay, or concrete Dike area must be of a size to hold the quantity of the largest tank, displacement of additional tanks, and extra for rain water Tank Location All tanks must be placed at a safe distance from buildings: 10 feet from property lines and public right-of-ways and 5 feet from an occupied building. More than 1 tank, the separation must be at least 3 feet 20 feet minimum from propane tanks Tanks less than 1,100 gallons must have 40 feet of clear space perimeter Additional Information ND Fire Marshal 701-328-5555 1,100 gallons or less must be contained in only one tank Multiple tanks of 1,100 gallons or less must meet the requirements for spill control Avoid gravity feeding from tanks elevated above the ground Double-walled or vaulted tanks do not need dike spill control Piping for double-walled or vaulted tanks must enter the top of the tank Source: ND Administrative Code 10-07 and NFPA 30 & 395