www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Similar documents
Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

3DLevelScanner II TECHNICAL DATA SHEET

Plastic tube flowmeters Series PT/PS

Regards from the Team at Rheology Solutions.

Micro Motion Model D and DL Coriolis Flow and Density Meters

How To Use A Flowmeter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

OPTIMASS 6000 Technical Datasheet


How To Use A Ds340 (Dsp)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Software and Display instruments

Electronic Pressure Switch EDS 300

COMBIMASS. Technical Data COMBIMASS eco-bio +

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

OPTIMASS 1400 Technical Datasheet

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Electric Rotary Actuator - On/Off or programmable control actuator

Technical Data Sheet. 3DLevelScanner

Flow switches Series AD/VH

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Thermal Mass Flow Meter (Series MST)

Instruction Manual Differential Pressure Transmitter

SITRANS F flowmeters SITRANS F M

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Rosemount 751 Field Signal Indicator

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Digital inductive conductivity transmitter

Micro Motion 3098 Gas Specific Gravity Meter

AMTRON E-30 Compact heat and cooling meter

Inductive sensor NI10-M18-Y1X-H1141

Technical data sheet TDS0070

Electronic Control Devices The European Product Catalogue 2007

IMVIB. Online vibration monitoring for Ariel compressors

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Unidirectional Transmitter/ Receiver Units Introduction

psens Pressure Measurement

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

2.12. page Products for Explosion hazardous Environment

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Floodlight Range Installation Guide

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

3500/93 System Display

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Microcor Wireless Transmitter (MWT)

Technical Information RIA14

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Fluxi 2000/TZ Turbine Gas Meter

EBS852 (Contrac) Power Electronic Unit

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

IFC 070 Technical Datasheet

S-series Mass Connection Solutions

Duct Humidity Transmitter

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

How To Use A Corona Mdi 110

Thermometer in stainless steel with capillary and switch contacts

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

ZHM Series Installation and Operating Instructions

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Series DFMT Digital Paddlewheel Flowmeter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

HERZ-Thermal Actuators

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Multi-Range Programmable DC Power Supplies 9115 Series

ENAiKOON ultrasonic fuel-level sensor

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

Series 6000 Torque measured metal bellow coupling

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

S300 Series Dust Monitors

On-line Machine Condition Monitoring [The CMS System]

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

R&S SMZ Frequency Multiplier Specifications

Solenoid Valve Island Type 3965

Terminal Boxes Series 8146

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Transcription:

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Description The Tricor Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different measuring instruments. Due to a construction free of dead spots the meters are well flushable and can be easily sterilized. The Tricor Mass Flow Meters do not contain any moving parts and consequently are suited for polluted media as well. According to the requirements the Tricor Mass Flow Meters are available as compact version with on site display and remote version with electronis in a wall mount or panel mount housing. For the compact version an additional remote display (TRD 8001) is available, designed for cable lengths up to 1 km. Principle Two parallel flow tubes inside the TCM Flow Meter are vibrating at their resonant frequency in opposite direction. Any mass flow passing through the tubes will delay the vibration at the incoming side and accelerate the vibration at the outgoing side. This causes a small time delay between both ends of the tube. This time delay is measured and used to calculate the mass flow through the tubes. By measuring the resonant frequency of the tubes the mass of the medium and - given a constant volume inside the tubes - the density of the medium can be calculated. As both effects are temperature dependent, the temperature is measured via a precise sensor for correcting the temperature effects of flow and density measurement. As a consequence a Tricor Mass Flow Meter directly measures mass flow, density and temperature of the medium. Knowing the mass flow and the specific cravity, also the volume flow can be calculated. Application Flow measurement of PU components and paints Flow measurement of aggressive and contaminated media Measurement of mass flow, density, temperature and volume flow Features Pmax. 350 bar Short response time DKD calibration Excellent puring and sterilization qualities due to a construction free of dead spots Up to +150 C medium temperature Individual 8-point-calibration including report Ex protection according to ATEX, IECEx, CSA cus Cycle of excursion (simplified) Rotation and deformation of two parallel looped pipes by the Coriolis force Fc. Movement to the inside no flow Movement to the inside with flow Movement to the ouside no flow Movement to the outside with flow 2

Overview Compact version with TCE 8000 Remote Display TRD 8001 Exd housing for wall-mounting (separated version, also with flange ends) Remote panel-mounted housing (separated version, also with flange ends) Compact version with TCE 6000 and TRD 8001 Compact version with KCE 8000 ATEX / IECEx 3

Technical Data - TCM Transducer Flow range (kg/h) Flow range (lb/min) Flow range (l/h) TCM0325 TCM0650 TCM1550 TCM3100 TCM5500 TCM7900 TCM28k TCM65k 3 to 300 0.11 to 11 3 to 300 6 to 600 0.22 to 22 6 to 600 15 to 1500 0.55 to 55 15 to 1500 30 to 3000 1.1 to 110 30 to 3000 Basic Accuracy (% of flow reading) 0.1 Zero Stability (% of full scale) 0.01 Zero Drift (% f.s. per C) 0.001 Repeatability (% of flow) 0.1 55 to 5500 2.0 to 200 55 to 5500 79 to 7900 2.9 to 290 79 to 7900 280 to 28 000 10 to 1030 280 to 28 000 650 to 65 000 24 to 2390 650 to 65 000 Density measuring range Density accuracy 0-4,500 kg/m³ ± 0.002 kg/ltr Temperature accuracy ±1 C ±0.5% of reading Process and Ambient Process connections female thread 1/2 flanges EN1092, ANSI B16.5, DIN2512 adaptors for flanges, diary and tri-clamp Max. pressure 200 bar 350 bar 100 bar Max. pressure (Option) 350 bar Pressure Drop at max. flow H 2 0 ask KEM Operating Density range 500-2,500 kg/m³ (standard), 5-4500 kg/m³ (upon request) Process temperature -40... +100 C (standard) / -100... +150 C (upon request) Ambient temperture -40... +70 C Storage temperature -40... +100 C Electr. connections remote screw type terminals Electr. connections compact. none (internally connected to the electronics) Ingress Protection IP65 (IP67 on request) General Tube arrangement 2 serial 2 parallel 2 serial 2 parallel 2 parallel 2 parallel 2 parallel 2 parallel Tube inner diameter 4mm 4mm 8mm 8mm 7mm 9mm 16mm 28mm Tube material stainless steel DIN 1.4404 Housing material stainless steel DIN 1.4301 Dimensions see drawings 4

Technical Data - TCE 8000 Transmitter General Display Supply votage Programming Interface Graphic, 132 x 32 dot 24 VDC, ± 20% and / or 100-240 VAC (version dependent) via front keyboard RS 485, Option HART, option Foundation Fieldbus EMC according to EN 61000-6-4 und 61000-6-2 Power consumption Exd housing Dimensions Connections Material Protection class Weight Temperature Panel-mounted housing: max. 4 W see drawing internal clamp terminals cable gland for 7-13 mm cables aluminium diecast IP 65 (IP 67 on request) approx. 2 kg operating: - 40 up to 70 C (up to + 80 C on request) storage and transport: -40 up to 80 C Dimensions see drawing Connections rear clamp terminals Material Noryl Protection class front: IP 50, rear: IP 30 Weight < 500g Temperature operation: 0 to 60 C storage and transport: -20 up to 70 C Analog Outputs Two current outputs Resolution Linearity Temperature drift Load Output value Pulse Output Frequency range Output signal Status In-and Output Status output Control input Analog Input (option) Input type Resolution Linearity Temperature drift Supply voltage 4-20 ma passive, two-wire, isolated 14 bit ± 0.05% of full scale 0.05% per 10K < 620 Ώ (at 24V supply) programmable: flow, total, density, temperature 0.5-10,000 Hz active push pull output for flow rate push pull programmable programmable 4-20 ma active for two-wire passive pressure sensor 12 bit ± 0.05% of full scale 0.05% per 10K > 20V (at 20 ma sensor current) 5

Technical Data - TCE 6000 Transmitter General Supply voltage 24 VDC, ±20% Programming via interface Interface RS485, USB (option) EMC according to EN 61000-6-4 and EN 61000-6-2 Power consumption max. 4 W Connections connectors M12 Material aluminium diecast Temperature operation: -40 to +70 C storage: -40 to +80 C Ingress protection IP 65 Analog Outputs Current output 4-20 ma active Resolution 14 bit Linearity ± 0.05% Temperature drift 0.05% per 10K Load < 800 Ώ Output value programmable: flow, total, density, temperature Pulse Output Frequency range: Output signal: Status In-and Output Status output Control input 0.5-10,000 Hz active push pull output for flow rate Push Pull programmable (option) programmable (standard: 1 input / option: 2 inputs) Technical Data - TRD 8001 Remote Display Display Supply voltage Programming Graphic, 132 x 32 dot via interface Interface to TCE RS 485 via front keyboard EMC according to EN 61000-6-4 und 61000-6-2 Dimensions 90 x 120 x 50 mm3 (h x w x d) Connections Material connector M12, B coded ABS-FR Protection class IP 64 Weight approx. 500g Temperature operation: 0 to 60 C storage and transport: -20 up to 80 C Wall mount hidden screws 6

Ex Certifications ATEX IECEx CSA Ex Zone 1: Group IIC or IIB, T4 Zone 2: II 3G Ex na IIC T4 Gc Zone 1: Group IIC or IIB, T4 Division 1: Group C,D, T4 Accuracy % 1,5 1 0,5 Accuracy Basic Accuracy + Zero Stability max. Flow Current Flow 0-0,5-1 -1,5 0 10 20 30 40 50 60 70 80 90 100 Flow % 7

Dimensional drawing (mm) TCM 5500 to TCM 65k L I.D. H C B Sensor Type B C H L* I.D. Connection** TCM 5500, 7900 61 204 260 460 Ø 13 a. N. TCM 28k 80 253 315 625 Ø 23 a. N. TCM 65k 151 387 480 830 Ø 40 a. N. * further lengths on request ** flange types on request Dimensional drawing (mm) TCM 0325 to TCM 3100 L D 70 G 22 60 E H C A 8 Sensor Type A C D E H L G TCM 0325 214 160 M6 10 15 182 110 G ½ TCM 0650 214 160 M6 10 15 182 87 G ½ TCM 1150 350 258 M6 10 18 280 140 G ½ TCM 3100 350 258 M6 10 18 280 140 G ½

Dimensional drawing (mm) On site Electronics C 115 203 110 222 202 118 Dimensional drawing (mm) Big on site Electronics E 136 238 132 250 224 144 128 9

Dimensional drawing (mm) On site Electronics TCE 6000 64 56 98 38 Dimensional drawing (mm) Connection Head 115 68 79 48 72 10

Dimensional drawing (mm) TCE 80xx - W 11

Dimensional drawing (mm) TCE 80xx - E with cable connection 189 147 265 4x Ø 5,7 Dimensional drawing (mm) TCE 80xx - E with Junction Box 189 147 265 4x Ø 5,7 45 Ø 132 45 8 45 Ø 132 186 238 8 45 318 238 12

Dimensional drawing (mm) Panel-Mounted Housing (drawing not to scale) Type A B - - - - - TCE 80** - S 96 96 - - - - - TCE 80** - L 96 144 - - - - - Dimensional drawing (mm) Remote Display TRD 8001 90 16 48 A B 83 8 144 120 13

Ordering Code TCM code 028k (4 digit) Maximum Flow in kg/h code Ax Dx Fx process connections (2 digits) ANSI flange x = size of flange, contact KEM / AWL for code DIN flange x = size of flange, contact KEM / AWL for code Female thread x = size of thread, contact KEM / AWL for code code Mechanical options (4 digits) X000 Temperature range S = -20 to 100 C H = -20 to 150 C 0X00 Pressure range G = 100bar with rupture disc For other ranges contact KEM 00X0 Accuracy (S = standard) 000X Flange to flange length, contact KEM/AWL for code code Electronics / terminal (4 digits) X000 Electronics A = junction box C =C = On site electronics TCE 8000 E = Big on site electronics TCE 8000 (Ex) F = On site electronics TCE 6000 CX00 Interface S = RS 485 only A = Hart + RS 485 B = Foundation Fieldbus and RS 485 C = HART and Foundation Fieldbus and RS 485 D = Foundation Fieldbus only E = Hart and Foundation Fieldbus Z = not used C0X0 Supply voltage D = 24V DC M = 90-264V AC Z = no used C00X Options S = none A = Pressure compensation, 4-20 ma input code Ex-protection Ex ATEX + IECEx Ex1 ccsaus Exn ATEX zone 2 empty no Ex-protection TCM 028k - DC - SGSS - EADS - Ex Please ask KEM/AWL or your or your nearest nearest dealer dealer for the for possible the possible combinations combinations and the best and solution the best for your solution application. for your application. 14

code 8001 8011 (4 digits) Low Power Electronics for TCM 0325 to TCM 7900 High Power Electronics for TCM 28K to TCM 65K code W S E L housing (1 digit) Wall-mounted housing with fixed cable to TCM Panel-mounted housing (separate cable required) Big wall-mounted housing with fixed cable to TCM or with junction box Wide panel-mounted housing (separate cable required) (Ex) code X000 0X00 00X0 000X Options (4 digits) Interface S = RS 485 only A = Hart + RS 485 B = Foundation Fieldbus + RS485 C = HART + Foundation Fieldbus + RS485 D = Foundation Fieldbus only E = Hart + Foundation Fieldbus Z = not used Power Supply B = 24V DC + 90-264V AC (Housing S only) D = 24V DC M = mains (90-264V AC) Options (S=none) A = Pressure compensation and 4-20mA input Cable length Housing "E": S = 3m, for other lengths contact KEM/AWL A = junction box, separate cable required Housing "L": N = no cable included code Ex Ex1 Exn empty Ex-protection ATEX + IECEx ccsaus ATEX zone 2 no Ex-protection TCE - - - Example: TCE 8011 - E - BDSS - Ex 15

Contact KEM Headquarter Liebigstraße 5 85757 Karlsfeld Germany T. +49 8131 59391-0 F. +49 8131 92604 info@kem-kueppers.com KEM Service & Repairs Wettzeller Straße 22 93444 Bad Kötzting Germany T. +49 9941 9423-0 F. +49 9941 9423-23 info@kem-kueppers.com More distributors & partners can be found at: www.kem-kueppers.com Your local partner: www.kem-kueppers.com info@kem-kueppers.com KEM Küppers Elektromechanik GmbH Liebigstraße 5 D-85757 Karlsfeld Tel +49 8131 59391-0 Fax +49 8131 92604 Copyright KEM, Subject to change without notice, ES Rev. 004-28/02/2013