Data Communications Competence Center



Similar documents
with Component Rating A Simple Perspective

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Enhanced Category 5 Cabling System Engineering for Performance

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

Power over Ethernet (PoE)

Network Design. Yiannos Mylonas

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Implementing Fast Ethernet

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Nexus Technology Review -- Exhibit A

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

White Paper. Crestron 8G DigitalMedia Cable

Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements

How To Get A Better Signal From A Fiber To A Coax Cable

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

How to Choose the Right Cable Category

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

Security & Surveillance Cabling Systems

Chapter 4 Connecting to the Internet through an ISP

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Gigabit Ethernet on Copper Cabling Infrastructures

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Sending A/V Signals Over Twisted Pair Cables: An Introduction. What is A/V over twisted pair?... 2

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

Understanding the Electrical Performance of Category Cables

Crosstalk effects of shielded twisted pairs

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Total Solutions Verification

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

100BASE-SX Fast Ethernet:

Gigabit Switching Ethernet Media Converters - Product User Guide

Fast Ethernet and Gigabit Ethernet. Networks: Fast Ethernet 1

Industrial Ethernet The Perfect Cable for an Imperfect Environment

Current Probes, More Useful Than You Think

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

10 Gigabit Ethernet over copper: Unshielded, unprotected?

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

Networks. The two main network types are: Peer networks

Fast Ethernet and Gigabit Ethernet. Computer Networks: Fast and Gigabit Ethernet

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Model CFA-24 Transparent Cable Farm Automation Switch

Annex 113A Description of cable clamp and test setup. (informative) 113A.1 Overview

32-bit PCI 10/100/1000Mbps Gigabit Ethernet Card. User s Guide. FCC Warning. CE Mark Warning. VCCI Warning

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

This is a product of VCCI Class B Compliance

PD Power Bandwidth- Worst Case Analysis July 2008

Ethernet Patch Cord Wiring

Ethernet Cat 5e & Cat 6 Patch Panels

GEU Port Gigabit Switch

Category 8 Cabling Standards Update

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

WHITE PAPER December, 2001

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

Computer buses and interfaces

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

2 Network Media. Copper Core Cable

Network Engineers Everywhere:

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Broadband Video over Twisted Pair Cabling. By Paul Kish Director, IBDN Systems & Standards NORDX/CDT

Media Conversion in Video Security and Surveillance Systems

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

INTRODUCTION TO 100BASE-T: FAST (AND FASTER) ETHERNET

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

EECC694 - Shaaban. Transmission Channel

Frequently Asked Questions

With the advent of Gigabit Ethernet

16-Port and 24-Port 10/100 Switches

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Specification SFTP CAT6 Network Cable 23AWG CU

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

CCNA 1: Networking Basics. Cisco Networking Academy Program Version 3.0

Category 6 UTP - Cabling System

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Transcription:

Importance of Cable Balance For Improving Noise Susceptibility Data Communications Competence Center DCCC03101702 July 11, 2007 Summary In a study of category 5e and category 6 UTP cables, a strong correlation is found between noise immunity and balance. Evaluation of cables using Longitudinal Conversion Loss (LCL) for cable balance and Electrical Fast Transient (EFT) noise to assess noise susceptibility demonstrates that well balanced cables are much less susceptible to external noise. Category 6 UTP cables are shown to have better balance than category 5e UTP cables indicating that category 6 cables minimize the number of errors due to noise on Ethernet data traffic. Background What is cable balance and how is it measured? Cable balance is an important parameter in modern high-speed computer networks. In category 5e or category 6 cables, the pairs are twisted to improve the immunity to noise and crosstalk as well as reduce emissions. The cable is designed so that the impedance of the two wires of each pair is balanced relative to ground. Ideally, unwanted noise and crosstalk is coupled equally onto both conductors of a pair and subtracted from the signal by the differential receiver in the switch or network adapter. In the real world, pairs are not perfectly balanced so the receiver is unable to remove all the noise leading to possible errors and reduced network reliability. Longitudinal Conversion Loss (LCL) is a measure of well a pair is balanced and provides a useful metric of a cable s ability to reject noise from external sources and to limit electromagnetic radiation from the cable to the environment. Examples of external noise sources include noisy power lines and electrical equipment, walkie-talkies, radio and radar stations, and alien cross talk from other telecommunications cables. As structured cabling is applied in industrial environments and as network speeds increase, balance is becoming increasingly important. The importance of balance in UTP is demonstrated by the recent standards activities related to balance. The Telecommunications Industry Association (TIA) has made recommendations concerning balance of cable and connectors in the category 6 standard (TIA/EIA-568-B.2-1). The TIA TR-42.7 Balance Task Group is currently studying cable balance measurement methods and recommended specifications. In the test procedure currently recommended by TIA, longitudinal conversion loss (LCL) is measured using a network analyzer by injecting a differential mode signal between the wires in a pair and measuring the resulting common mode noise signal between the pair and ground. LCL is the ratio between these signals expressed in decibels (db), with higher values indicating better balance. By optimizing cable design and manufacturing processes, manufacturers can manufacture cables with enhanced balance. 132 White Oak Road, New Holland, Pennsylvania 17557 Phone: +1 717 354 6200 Fax: +1 717 354 7933

What is EFT and why is it used to measure noise susceptibility? The EFT test signal was originally developed to test susceptibility of electrical devices to high-voltage spikes on power lines. The EFT pulses, as specified in International Electrotechnical Commission (IEC) 801-4, are a good representation of real noise on power lines. Such noise is typically generated by office equipment (particularly equipment with electric motors) and switching transients for fluorescent lighting. The frequency content of the EFT pulses is within the bandwidth of modern computer networks and cabling systems. Since EFT noise is both common in a commercial environment and occupies the same frequencies spectrum as the network signals, EFT noise susceptibility measurements performed on data cables with controlled separation to a power cable provide a good indication of overall noise immunity of cabling systems. Test Setup Cable Selection 1000-foot spools (or boxes) of 14 different cables were procured from distribution. These included seven category 5e and seven category 6 cables from six different manufacturers. Three 100-meter lengths were cut from each spool and subjected to both balance and EFT testing. Balance Measurement Cable LCL was measured in accordance with TIA/EIA-568-B.2-1 Annex D and compared to the recommended limit in clause 7.6.1.1 of the same document: LCL cable 30 10log( f / 100)dB with values above 40 db reverting to 40 db. Please note that while this recommendation applies only to category 6, it was also used it for comparison purposes for category 5e. EFT Noise Susceptibility Measurement Each cable was shortened to 90 meters, terminated to connectors of the appropriate category, and the resulting link connected to ports of a Gigabit Ethernet switch using patch cords. The switch was connected optically to two ports on an Ethernet LAN analyzer. Full duplex, Gigabit Ethernet traffic (1000BASE-T) was passed over the link. 10 meters of 12-2 type NM power cabling was placed with minimal separation next to one end of the link and was in turn connected to the output of an EFT generator. The test setup is shown schematically in Figure 1. Page 2 of 7

LAN ANALYZER ETHERNET SWITCH ETHERNET SWITCH LOAD EFT GENERATOR 10 m 90 m Figure 1: EFT noise immunity test setup At increasing EFT voltage settings, Gigabit Ethernet packets were sent containing a total of 10 11 bits and the number of errors recorded. Using the total number of EFT pulses during the test time, a ratio between errors and noise pulses was calculated and graphed. Test Results Cable LCL A significant difference was seen between category 6 cables and category 5e cables as a group, with the category 6 cables performing much better than category 5e cables. The single exception was one category 6 brand which had the worst performance of all cables tested. It is noted that all samples exceeded the recommended LCL limit in TIA/EIA-568-B.2-1. Figures 2 and 3 show the LCL performance of the worst and best cables compared to the recommended limit for category 6. Page 3 of 7

100 80 LCL (db) 60 40 20 Limit 0 1 10 100 1000 FREQUENCY (MHz) Figure 2: LCL measurement for worst category 6 cable 100 80 LCL (db) 60 40 20 Limit 0 1 10 100 1000 FREQUENCY (MHz) Figure 3: LCL measurement for best category 6 cable The best cable, a category 6, had nearly an 18 db margin. The category 5e samples exceeded the recommended limit by less than 8 db. The worst cable meets the recommended limit with a margin of 1 db. Page 4 of 7

EFT Noise Susceptibility Similar to the balance results, category 6 cables outperformed category 5e in the EFT noise susceptibility tests. The one exception was the same brand of category 6 that had exhibited the worst LCL performance. Figure 4 shows EFT noise susceptibility for the best category 6 cable, typical category 5e, typical cat 6 and the worst cable. The worst sample, a poorly balanced cable, begins to experience errors at just over 10 V induced common mode noise. The typical category 5e cable was almost twice as good with errors beginning at about 20 V. The best category 6 cable was better still. It achieved nearly error free performance with 40 V induced common mode noise. At this noise level all of the category 5e samples had 100% errors per pulse. 100% Worst cable Typical Cat 5e Typical Cat 6 Best Cat 6 ERROR/PULSE RATIO 80% 60% 40% 20% 0% 0 10 20 30 40 50 60 INDUCED CM NOISE (V peak) Figure 4: EFT noise susceptibility measurements Correlation of EFT Noise Susceptibility and LCL Measurements For each cable sample, the voltage where the ratio of errors to noise pulses equaled 10% was calculated. These voltages were graphed in a scatter chart vs. cable LCL margin above the recommended limit. Figure 5 shows the correlation. The trend line was derived using linear regression across all samples. As a group, the category 6 cables with LCL margins of more than 10 db performed much better than the category 6 cables with lower margins and all the category 5e cables. Page 5 of 7

Note that all three samples of the worst category 6 cable are in the lower left corner of the chart showing poor balance and poor EFT susceptibility performance. 2500 EFT Pulse Voltage at 10% Errors 2000 1500 1000 500 Category 5e Category 6 0 0 5 10 15 20 LCL MINIMUM MARGIN (db) Figure 5: Correlation of EFT noise immunity and LCL measurements Conclusions There is a strong correlation between cable balance (LCL) and the threshold noise voltage at which network errors occur. A direct relationship between balance and noise immunity is shown with better balanced cables corresponding to better noise immunity. In general, category 6 cabling provides better balance and immunity than category 5e cabling. However, not all category 6 cables provide this extra protection showing the differences in cable design and manufacturing consistency. This also occurs because the current recommended limit in TIA/EIA-568-B.2-1 is not mandatory and is too low. As Ethernet networks move into the industrial environment, they can be exposed to much higher noise voltages than are seen in an office environment. Draft documents from TIA TR-42.9 (Industrial Telecommunications Cabling) require EFT testing to voltages up to four times higher than for commercial equipment. Gigabit Ethernet implementation is increasing. In addition, IEEE 802.3 has formed a study group to determine the feasibility of 10 Gigabit Ethernet over copper cabling which is expected to become the P802.3an task group in early 2004. The increased data rate will require higher signaling speeds and more complex encoding resulting in increased susceptibility to external noise. Page 6 of 7

Balance for the current Gigabit Ethernet networks and the developing Industrial Ethernet and 10 Gigabit Ethernet will gain noise immunity from better balanced cables. For the best performance, category 6 cables with at least 10 db of margin above the existing limit should be specified. Table 1: Definitions of Acronyms Abbreviation Description EFT Electrical Fast Transient EIA Electronic Industry Alliance IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers LAN Local Area Network LCL Longitudinal Conversion Loss TIA Telecommunications Industry Association UTP Unshielded Twisted Pair Data Communications Competence Center Nexans Data Communications Competence Center, located at the Berk- Tek Headquarters in New Holland, Pennsylvania, focuses on advanced product design, applications and materials development for networking and data communication cabling solutions. The Advanced Design and Applications team uses state-of-the-art, proprietary testing and modeling tools to translate emerging network requirements into new cabling solutions. The Advanced Materials Development and Advanced Manufacturing Processes teams utilize sophisticated analytical capabilities that facilitate the design of superior materials and processes. The Standardization and Technology group analyzes leading edge and emerging technologies and coordinates data communication standardization efforts to continuously refine Nexans Technology Roadmap. An international team of experts in the fields of cable, connectors, materials, networking, standards, communications and testing supports the competence center. The competence center laboratories are a part of an extensive global R&D network that includes eight competence centers, four application centers and two research centers dedicated to advanced technologies and materials research. Page 7 of 7