Best Practices for Removing Vehicles from Cable Barrier for the NC Guardrail Committee



Similar documents
High Tension Cable Median Barrier: A Scanning Tour Report

NUCOR U.S. High Tension Cable Barrier System INSTALLATION MANUAL

X-Tension TM Guardrail End Terminal

CABLE MEDIAN BARRIER

Safety Performance of the Median Cable Barrier. Deerfoot Trail, Calgary, Alberta UPDATE

HEART Product Description Assembly Manual

EMPLOYEE FALL PROTECTION

DESIGN OF A TL-4 MEDIAN CABLE BARRIER FOR DEERFOOT TRAIL, CALGARY

Washington State Cable Median Barrier In-Service Study

HIGH TENSION CABLE BARRIER

EVALUAT ING ACADEMIC READINESS FOR APPRENTICESHIP TRAINING Revised for ACCESS TO APPRENTICESHIP

SKT-SP Tangent Terminal

How To Ensure Safety Of Lifting Equipment

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

62 nd Annual Missouri Traffic and Safety Conference. M.A.S.H.: The New Safety Hardware Crash Testing Criteria

guidance on barrier selection, guidance on barrier design, guidance on barrier placement, and guidance on general system considerations.

Capital Costs for Roadside/Median Barrier Systems

INSTALLATION INSTRUCTIONS

Fall Protection System: A system put in place to protect workers from falling. (i.e. installation of guardrails, fall arrest, fall restraint, etc.

OSHA Remove impacted systems and components. Inspect systems prior to use.

INSTALLATION INSTRUCTIONS

How To Use A Tracc Crash Cushion

POTENTIAL HEALTH & SAFETY HAZARDS

Structural Holding System

Coaxial Cable Installation Accessories

Notes. Material 1. Tools the employee is expected to operate

MKV Golf GTI Rear Brake Service - Replace Pads and Rotors

CONSTRUCTION SAFETY. NOTE: Barriers, guards, and warning signs are required to ensure safety against existing hazards.

TECHNICAL QUESTIONS AND ANSWERS ITN-DOT-14/ RM TAMPA OPERATIONS CENTER VIDEO SURVEILLANCE/SECURITY ACCESS SYSTEM

Stephen Gaj. Martin Kidner State Planning Engineer Wyoming DOT

1What purpose do guard

Cable Preparation and Pulling Procedure Best Practices for Fiber Optic Indoor Tight-Buffered Cable

Solstice/Sky Water Pump Replacement

INSTALLATION INSTRUCTIONS FOR VW MK5

Contents. Front Derailleurs Part One - Planning... 2 I. Objectives... 2 II. Materials Needed... 2 III. Setting...2 IV. Evaluation...

Alarms of American Mantel Clocks By David J. LaBounty, CMC FBHI

SECTION GUARDRAILS

AERIAL FIBER OPTIC CABLE PLACEMENT

INSTRUCTIONS FOR CHAIN LINK INSTALLATION Chain Link fence & Posts Meshdirect.co.uk

Development of Guidelines for Anchor Design for High-Tension Cable Guardrails

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION

Introduction to Fall Protection

R O A D M A S T E R, I N C.

VI. VEHICLE IMPACT WITH CURB-AND-GUARDRAIL SYSTEMS. high-speed roadways, they are often required because of restricted right-of-way, drainage

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Table of Contents. I. Working Directions...2. II. System Introduction...3. III. Wiring Installation Product Parts List...

This kit may void factory warranty please check with manufacturer.

Pinole Fire Department

GENUINE PARTS INSTALLATION INSTRUCTIONS

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

COMPETENCY ANALYSIS PROFILE. Rodworker 452A. (All unshaded skill sets must be demonstrated/ completed) Lift equipment and materials

WILDING WALLBEDS BUNK BED INSTALLATION INSTRUCTIONS

Summary of ET Plus Guardrail End Treatment Inspections

Session 3: Guardrail Design and Sitespecific. Considerations

ABC-CMEF Craft Training Program CORE Audit Checklist

The Lever. The law of conservation of energy applies to all machines!

3088 Lockout-Tagout Training Program Course Outline

Fitting Instructions Garador, Westland & Catnic Garage Door Spring Box Roller Wheels & Wall Bracket & Link Arm

High-tension Median Cable In-service Performance Evaluation and Cost Effectiveness Analysis

National Traffic Incident Management Responder Training Nebraska Update. Nebraska Asphalt Paving Conference February 11-12, 2014

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

STRING TELEPHONES. Education Development Center, Inc. DESIGN IT! ENGINEERING IN AFTER SCHOOL PROGRAMS. KELVIN Stock #651817

Series 90 Portable Capstan Hoist. Owners Manual ! CAUTION

Operator Training Questionnaire

CHAPTER 14: GUARDRAIL and BARRIERS

Safe handling when securing loads on trucks

How to re-string & re-cable the Genesis Compound bow. Step by step, picture by picture Right hand models ONLY

Fatality Assessment and Control Evaluation Project

Business Auto Insurance. made simple

Fall Hazards 1/3/2014. Introduction

TEACHER GUIDE 11.2 RISK MANAGEMENT AND INSURANCE PAGE 1

Procedure for Cutting and Respooling Fiber Optic Cable

Lowcountry Injury Law

INSTALLATION MANUAL UNIVERSAL TAU-II. NCHRP 350 TL-3 Redirective, Non-Gating, Crash Cushion

Roll-Up Door Maintenance Guide

Responsibilities of a Volunteer Leader

INSTALLATION INSTRUCTIONS MULTI-MOUNT KIT Part Number: Application: Warn HP PowerPlant P/N 71800

Minnesota State Patrol Fatal Crash Investigation May 23 rd, 2009 US Hwy 63 & MN Hwy 30

INSTALLATION INSTRUCTIONS

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

National Wraparound Initiative Technical Assistance Call Transcript. Family Members as Wraparound Facilitators And Funding Wraparound with Medicaid

Vehicle Recovery and Towing

Installation Manual For Support Call or

Retrofit Instructions Installing a Sport Heated Steering Wheel - Leather, Multifunction BMW X5, E53,

Sebring Timing Belt and Water Pump Replacement

8' W x 8' H or 10' H Peak Style Shelter Assembly Instructions

Internship Experience Report

Leading Causes of Wildfires in Oregon

Technical Report Documentation Page 2. Government Accession No. 3. Recipient's Catalog No. 1. Report No. FHWA/TX-09/

Working safely under motor vehicles being repaired

Installation Guide 2010 BMW S1000RR Full Exhaust System

M-2004-MBA Brake Duct Kit 2013 BOSS 302, Mustang GT and California Special INSTALLATION INSTRUCTIONS

Transcription:

Best Practices for Removing Vehicles from Cable Barrier for the NC Guardrail Committee Since the last Committee Meeting on March 15, 2006 we have been sending out emails to the AASHTO TIG-CMB team members to find out their experiences and best practices for removing vehicles from cable barrier. The attached photo from the Charlotte Fire Department, labeled as saab trapped in cable.jpg, spawned this inquiry. The following information summarizes the email responses we received from various persons. After reading this summary and reviewing the attachments and videos, please let me know what direction the Committee would like to go with this topic. For instance, does this give us the answers we needed? Do we need to put some standards/best practices together for the rescue teams or maintenance personnel based on this information? Let me know your thoughts and ideas. Reynolds - NCDOT Cable Barrier Contractor From speaking with Reynolds it seems like they have dealt with this issue a good bit in the past. Reynolds recommendations are to go to the anchor unit and release the tension there UNLESS it is a life or death situation. This does the least amount of damage to the system and is the least expensive to fix. The bolts can be loosened with a typical wrench. If the car needs to be removed immediately, the cable should be cut and then spliced back together. They are setting up a section of cable guardrail in Concord at their firefighter's training facility so their staff can practice on releasing the tension. NCDOT Mecklenburg County Maintenance Engineer For the subject crash this was the response: Would prefer them not to cut the cables concerned over backlash when cutting. He prefers getting contractor to come release tension he s not sure what would happen after hours. He was not sure what to do if someone was injured and had to be removed from car quickly. Said he would speak with his district engineer and see if he had any comments. The district engineer was called in on the subject crash. He called Reynolds and got them to come out there and release the tension on the system. He had plenty of time since no one was injured. NCDOT Pender County Maintenance Engineer What we are doing is to tell them to cut the cable and we will fix cable when repairs are done and send the bill to the party responsible. I have talked with some of my supervisors about this concern. They are telling me that a cut off saw is the best way to cut the cable. And concerning the backlash, they have also advised that when they have to cut the cable that there is not a lot of tension so they do not experience a lot of backlash.

Arizona DOT - Terry Otterness The following information is from our maintenance folks regarding the low-tensioned 3-cable system that we have in place. Yes we have spliced it back together in cases where we had to cut it to free a vehicle. Usually that is when it gets wrapped up pretty tight in some part of the drive train. We also have cases where the repair contractor and our crew determine that a kink is too severe to remain in the strand so we cut out the kink and then splice it back together. FHWA - Richard Powers I have seen a video prepared by one of the cable barrier manufacturers showing a high-tension cable being cut with a power saw. The cable simply falls down rather than rebound as an elastic band would. I recommend you ask the manufacturers what they recommend for any of the proprietary systems. Perhaps the greatest concern would be the effort required to repair the cables after the vehicle is extricated. The basic question remains "does cutting a highlytensioned cable create a serious problem with the cut ends flying apart?" FHWA - Frank Julian I think Jerry s E-mail makes Richard s response more clear. They are not encouraging Fire Departments to cut the cable because of the damage it does to the system and added repair time and there are several other options. However, if it is deemed necessary, then cutting the cable does not pose lose of life and limb to responders. The video I am sending you will help alleviate fear among responders and cable Nay Sayers. We will have to put this on the future website to alleviate urban legends among firefighters. The videos referenced above have been placed on the following link and are labeled as follows: Cutting Cable.wmv and MarionCableCutting.avi ftp://ftp.dot.state.nc.us/dept-units/traffic/tssm/transfer/cablevideos/ Trinity - Rich Figlewicz If a vehicle is snagged in the cable there are several approaches: 1.) If not deeply entangled you can go upstream and downstream and lift the cable out of the CASS post slot till the weight of the cable overcomes the tension and it lays on the ground (75' to 100' in each direction). This allows some latitude in being able to free the vehicle. 2.) Similarly going upstream and downstream to the closest turnbuckles and loosening them a few turns will release tension.

3.) If deeply entangled, as we have seen with 18-wheeler involvement, and it is felt that it is necessary to cut the cable it is best to do it 250 to 300' away from the vehicle. Although the tensioned cable will not "whiplash" (especially the pre-stretched type) it is better to be safe. Either hydraulic cutters or an abrasive blade cutoff saw can be used. 4.) We have had one instance of the cable tearing and that was in MN where a 90,000# truck going over 70 mph snagged and tore a cable as it passed into the median. The DOT simply replaced the 1,000' section with a new piece. This involved just hand tools and loosening of the turnbuckles. The same thing can be done if any of the end terminal cables are torn or cut...there is a CASS part number for each section of cable. The price for the new cable with pre-swaged ends is probably a trade-off when considering the purchase of the field-applied fittings and labor / time needed to splice in a new cable section. If it is decided that the DOT wants to replace the cut section you can, for instance, remove a 3' section (or whatever length desired) and replace with an equal length section using a field splice "torpedo" at each end of the cut. Again, this is a common part which has been used for years with the U.S. Standard system. Gibraltar - Jay Winn We get approximately a dozen system hits per month. In no case has the vehicle been entangled in the cables. Our high tension cable barriers systems have contained and redirected the vehicles in every case. In the rare event that a vehicle is entangled and time or circumstance does not permit to utilized the turnbuckles to release some of the tension and the cable/s must be cut, we recommend that no person/s stand next to the cable barrier system and the person making the cut stand perpendicular to the cable barrier system extending the chop saw with their arms towards the cable. Cut cable in the center between line posts. Upon removing the vehicle from the system, splice the cable at cut with a turnbuckle. Brifen USA - Jerry Emerson I talked with Lyndal Wiseman, our field technical expert who has experience over nearly 6 years with Brifen WRSF here in OKC and he says he has never had to cut a cable. Several posts can be removed each way from the crash site (since the cables aren't rigidly attached) and that removes the weave, which gets enough slack in the cables to allow vehicle removal. He has never had to loosen a turnbuckle either. Training has been provided for EMS people to explain this. One state did have a cable cut by a wrecker driver who didn't understand the Brifen system, and we know of a different state where a wrecker driver loosened a turnbuckle. Cutting a cable is never recommended, since that would disable the system and cause unnecessary repair costs, but loosening a turnbuckle is OK...but it will mean having to re-tension that section of WRSF. We have had no situation where vehicles have wedged in between anchors, since Brifen doesn't use intermediate anchors. And the high tension in the cables prevents them from flying around and wrapping up a vehicle during a crash. The Arizona DOT may have some ideas, as they have

quite alot of the low tension 3-cable system and it gets hit alot due to high traffic volumes. Terry Otterness (602-712-4285) or Ken Cooper (602-712-8674) might know the details. The pictures show a vehicle between the cables, but it is not between two intermediate anchors, since there are no intermediate anchors. With the slack created by the cables being loose from many posts, it should have been possible to move the cables enough to free the car. However, if that wasn't possible, then the turnbuckles nearby could have been loosened, or even disconnected...a preferable option to cutting the cables. However, if a matter of life and death and the previous won't work, then cutting the cables might be done. Attached is the Brifen brochure for vehicle removal labeled as: Brifen Crash Vehicle Removal.pdf Brifen USA - Richard Butler Although there are several different types of systems (low tension and high tension) and several manufacturers of the high tension systems, they all use the same cable. It's a 3x7, 21 wire 3/4" (19mm) wire rope. I manufactured this cable for over ten years and supplied it to states and manufacturers, so that's where my knowledge comes from. The low tension cable system typically has 3 ropes that are held on the post by a J-shaped hook and used in medians in NC, SC and MO or used as a ROR roadside barrier in numerous states in the NE and Midwest. This rope is under very little tension and when engaged by a vehicle can pull loose from the hardware and get tangled. In most cases because of the slack introduced during the impact and subsequent release of the cables, there is no need to cut the cable. The high tension designs vary, but there are several options rather than cutting the cable. Let me say first, if a life is in the balance, cut the cable. There should be no major kickback from cutting it as long as you take proper shielding precautions and it is not under excessive force as it might be if tangled in a vehicle and pulled 10-15' from the center line of the fence section. There are two simple methods to remove the cable, but first, if the cables are tied up in a vehicle, pull the vehicle back towards the CL of the fence to take the lateral force out of the cable. If that does not introduce enough slack to get the cable out, you can loosen the tension at the rigging screws that connect the 1000' cable segments (need a couple of pipe wrenches and some muscle). Another option is to remove additional posts (if it's a socketed system) which will introduce some additional slack.