General Specifications



Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Manuals for This Product

General Specifications

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

DeltaV Remote Client. DeltaV Remote Client. Introduction. DeltaV Product Data Sheet. Remote engineering and operator consoles

General Specifications

For the latest information, check the product home page ( en/products/rack2_smart).

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Ultra Thin Client TC-401 TC-402. Users s Guide

DeltaV Executive Portal

SECTION CONTROL SOFTWARE

AXIS Camera Station Quick Installation Guide

Autodesk Building Design Suite 2012 Standard Edition System Requirements... 2

DiskPulse DISK CHANGE MONITOR

How To Use Safety System Software (S3)

NEC Projector User Supportware 2 Software Utility Installation Guide

Grant Management. System Requirements

Avigilon Control Center Server User Guide

Web Supervisor/Agent. System Requirements & Troubleshooting Guide. 989 Old Eagle School Road Wayne, PA (610)

Relational Production Information Control System PREXION TM with Smart Client MIB

WebEx. Remote Support. User s Guide

INSTALLATION GUIDE. AXIS Camera Station

Make your office the forefront of production

X Series Application Note 43:

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Autodesk 3ds Max 2010 Boot Camp FAQ

USB-MIDI Setup Guide. Operating requirements

Network Disk Recorder WJ-ND200

Customer Tips. Xerox Network Scanning TWAIN Configuration for the WorkCentre 7328/7335/7345. for the user. Purpose. Background

Core Protection for Virtual Machines 1

TeamViewer 9 Manual ITbrain

DVR4C Remote Viewer Operation Manual Table of Contents EN 3 1. OVERVIEW MINIMUM PC REQUIREMENTS INSTALLING THE PROGRAM...

Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015

Microsoft Office Outlook 2013: Part 1

For designers and engineers, Autodesk Product Design Suite Standard provides a foundational 3D design and drafting solution.

Abila Grant Management. System Requirements

General Specifications

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

================================================================== CONTENTS ==================================================================

Autodesk Inventor on the Macintosh

NETWRIX IDENTITY MANAGEMENT SUITE

FactoryTalk Gateway Getting Results Guide

Fleet Management System FMS. User Manual

PARALLELS SERVER 4 BARE METAL README

To get started, you will need the following items Product Key Router with firewall capability Network cables

Mitchell 1 / ShopKey Shop Management Installation

Licenses of savic-net for Integrated Building Management System for FDA Title 21 CFR Part 11 Compliance

Quick Start Using DASYLab with your Measurement Computing USB device

Fiery E100 Color Server. Welcome

LockView 4.2 CompX Database & Network Configuration & Installation Manual

Topaz Installation Sheet

Web VTS Installation Guide. Copyright SiiTech Inc. All rights reserved.

ION EEM 3.8 Server Preparation

Chapter 4 Control Center

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

DUKANE Intelligent Assembly Solutions

Sage Grant Management System Requirements

InventoryControl for use with QuoteWerks Quick Start Guide

Revit products will use multiple cores for many tasks, using up to 16 cores for nearphotorealistic

LockView CompX Database & Network Configuration & Installation Manual

Remote Support. User Guide 7.23

Autodesk Revit 2016 Product Line System Requirements and Recommendations

EasyMP Network Projection Operation Guide

PARALLELS SERVER BARE METAL 5.0 README

Setting up VPN and Remote Desktop for Home Use

intertrax Suite resource MGR Web

AXIS Camera Station Comprehensive video management software for monitoring, recording, playback and event management

Licenses of savic-net for Integrated Building Management System, and for FDA Title 21 CFR Part 11 Compliance

Using. Microsoft Virtual PC. Page 1

================================================================== CONTENTS ==================================================================

Kurzweil 3000 for Windows Network Installation and Administration Guide Version 11

Multi-Share User Instructions

User Guide Win7Zilla

About This Manual. 2 About This Manual

IT Essentials v4.1 LI Upgrade and configure storage devices and hard drives. IT Essentials v4.1 LI Windows OS directory structures

Web Server (IIS) Requirements

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

Solution Brief: Creating Avid Project Archives

Microsoft Office 2010 system requirements

TrueAlarm Fire Alarm Systems

REDCENTRIC UNITY SOFTWARE MINIMUM REQUIREMENTS

Synergis Software 18 South 5 TH Street, Suite 100 Quakertown, PA , version

EasyMP Multi PC Projection Operation Guide

Chapter 12: Windows XP, Vista, and 7

How To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On

Professional Surveillance System User s Manual

USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p

DCPS STUDENT OPTION HOME USE PROGRAM SIGN UP INSTRUCTIONS

Adept 2014 System Requirements

Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents

Microsoft product screenshots are reprinted with permission from Microsoft Corporation.

TECHNICAL BULLETIN. Checking the products and their versions that we have confirmed the operation on Windows 8 and Windows 8.1.

Using Virtual PC 7.0 for Mac with GalleryPro

Installing Emageon PACS Remote Ultravisual

Technical Specification Data

Transcription:

GR0001 Distillation column 100 100 Column flow AUT NR PV SV M3/H 70.0 M3/H 50.0 MV % 65.0 100.0 80.0 60.0 40.0 20.0 0.0 TDA 37.5 53.8 RC-10 23.4 % TRC 49.2 38.9 LICA 25.4 % 51.3 PAC LICA 45.7 % 48.9 Tank1 100 AUT NR TIC301 TIC301 100.0 0.0 TG1001 Block:10 Group:01 F I C 0 0 1. P V 102.3 82.3 62.3 42.3 22.3 2.3 2 1 00:12:00 100% 13:34 13:36 13:38 13:40 13:42 13:44 1 001. PV Inlet flow 72.1 M3/h 100.0 0.0 2 002. PV Outlet flow 53.3 M3/h 100.0 0.0 3 LIC100. PV Level 3.8 M 100.0 0.0 4 TIC100. PV Temp A 25.7 DEGC 100.0 0.0 5 TIC200. PV Temp B 14.1 DEGC 100.0 0.0 6 7 8 <<Contents>> <<Index>> General Specifications GS 33J05D20-01EN Model VP6H1150 Server for Remote Operation and Monitoring Function GENERAL CENTUM VP Server for Remote Operation and Monitoring Function can be executed from the remote computers for plant operation and monitoring. By using the terminal service (TS) server of the Windows Server, the Server for Remote Operation and Monitoring Function allows multiple computers which are connected with one server simultaneously operating and monitoring in the TS server. If a computer is located away from the instrument room, as long as the computer is connected to the HIS terminal service server through the network, the operation and monitoring view on the HIS can be displayed on the remote computer. The remote computer does not need to have the operation and monitoring applications. FUNCTION SPECIATIONS [Release 6] System Configuration The Server for Remote Operation and Monitoring Function runs on a in Windows Server OS, allowing it to be a server for remote-access operation and monitoring. If user names are entered and logged on from a network client computer connected to the server for remote operation and monitoring, the functions running on the server for remote operation and monitoring can be used on the client computer. Distillation column 41.4 TDT Client Computer Site Client Computer Intranet Office building CENTUM VP HIS Server for Remote Operation and Monitoring Vnet/IP FCS Central control room Figure Example of Configuration of Server for Remote Operation and Monitoring Function A maximum of eight simultaneous sessions (a session stands for a logic connection to the server for remote operation and monitoring function started from logon and ended at logoff) can be run on one server for remote operation and monitoring. Logging on from the server for remote operation and monitoring is also counted as one session. A client computer can display screens on a session-by-session basis regardless of the screens displayed on the server for remote operation and monitoring or on other clients. It may take a few seconds for the client computer to display the screens depending on the network speed. When using the Server for Remote Operation and Monitoring Function, please set up one or more standard HIS along with the client computer on the control network. The standard HIS has better reliability for real-time operations than the client computer. For instance, the control network communication fails between the Server for Remote Operation and Monitoring and the client computer, the operation and monitoring from the client computer become unavailable while the standard HIS continues its control and monitoring. F01E.ai Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 GS 33J05D20-01EN Copyright Feb. 2015 (YK) 2nd Edition Mar. 17, 2015 (YK)

2 Functions Available for Remote Operation and Monitoring The functions running on the server for remote operation and monitoring can be used on the client computer. Standard engineering functions realize engineering with a remote computer using the TS functions directly. In this case, the standard engineering function can connect only one session apart from eight sessions for operation and monitoring. System views on multiple computers, including the server for remote operation and monitoring, cannot be started simultaneously. However, if reference builders are called up in reference mode, screens can be displayed on multiple computers. Table Package Coexistence in the Server for Remote Operation and Monitoring (1/2) Model Name Coexistence Note VP6H1100 Standard Operation and Monitoring Function X VP6H1120 VP6H1130 Console HIS Support Package for Enclose Display Style Console HIS Support Package for Open Display Style VP6H2411 Exaopc OPC Interface Package (for HIS) X VP6H2412 CENTUM Data Access Library X VP6H4000 Million Tag Handling Package X When the OPC package is used on the remote operation and monitoring server, it behaves slightly different when it is used with the standard HIS. Confirm the operation of the application program under the server for remote operation and monitoring environment is required. The operation check is required in each created application. VP6H4100 Configured information Reference Package X VP6H4150 Output to External Recorder Package VP6H4190 Line Printer Support Package VP6H4200 Consolidated Historical Message (Meeting FDA) VP6H4410 Control Drawing Status Display Package X VP6H4420 Logic Chart Status Display Package X VP6H4450 Multi project Connection Package X VP6H4600 Multiple-monitor Support Package VP6H4700 Advanced Alarm Filter Package VP6H6510 Long-term Data Archive Package X VP6H6530 Report Package VP6H6660 Process Management Package X VP6H6710 FCS Data Setting/Acquisition Package (PICOT) A remote operation environment can be constructed by installing the Report Package in the client computer. Please define the server for remote operation and monitoring as a client station in the process management configuration definition. X: Yes : No GS 33J05D20-01EN Feb. 1, 2015-00

3 Table Package Coexistence in the Server for Remote Operation and Monitoring (2/2) Model Name Coexistence Note VP6E5000 Engineering Server Function X Only one session is available simultaneously. VP6E5100 Standard Engineering Function X Only one session is available simultaneously. VP6E5110 Access Control package X Only one session is available simultaneously. VP6E5150 Graphic Builder X Only one session is available simultaneously. VP6E5165 Batch Builder X Only one session is available simultaneously. VP6E5166 Recipe Management Package X Only one session is available simultaneously. VP6E5170 Access Administrator Package (FDA:21 CFR Part 11 compliant) X Only one session is available simultaneously. VP6E5210 Module-based Engineering Function X Only one session is available simultaneously. VP6E5215 Tuning Parameter Management Package (for Module-based Engineering) X Only one session is available simultaneously. VP6E5216 Bulk Editing Package (for Module-based Engineering) X Only one session is available simultaneously. VP6E5250 Change Management Package X Only one session is available simultaneously. VP6E5260 Dependency Analysis Package X Only one session is available simultaneously. VP6E5420 Test Function VP6E5425 Expanded Test Function VP6E5426 FCS Simulator Package VP6E5427 HIS Simulator Package VP6E5450 Multiple Project Connection Builder X Only one session is available simultaneously. VP6E5490 Self-documentation Package X Only one session is available simultaneously. VP6C5495 Electronic Instruction Manual X Only one session is available simultaneously. VP6P6920 Sem Sequence of Event Manager (for FIO) X X: Yes : No GS 33J05D20-01EN Mar. 17, 2015-00

4 Operation Screen Mode and Display Mode HIS provides two operation screen modes, full-screen mode and window mode. In each mode, HIS displays views such as the Graphic View or the Trend View. Moreover, a remote HIS terminal connected through the Server for Remote Operation and Monitoring Function package also has two display modes. Operation Screen Mode Full-Screen Mode In this mode, HIS displays a frame that consists of several views assigned for a certain function or purpose. On a standard HIS, a number of tabbed frames can be displayed and overlapped in full-screen mode. However, on a remote HIS terminal connected through the Server for Remote Operation and Monitoring Function package, only a fixed frame can be displayed. In this mode, a Pop-Up Window such as a Faceplate View can be displayed in front of the frame. Window Mode In this mode, several windows can be displayed in cascade style of Microsoft Windows so that the windows are overlapped. Each window contains only one view. Display Mode On a remote HIS terminal connected through the Server for Remote Operation and Monitoring Function package, the display mode can be either desktop mode or panel mode. The mode can be selected when the client computer is connecting to the server for the remote operation and monitoring services. Desktop Mode In desktop mode, the operation and monitoring activities on a remote HIS can be carried out in the same style as on a standard HIS where the System Message Banner is displayed on the top and the Browser Bar is displayed on the left. Browser Bar System Message Banner HIS0163 - Remote Desktop Recycle Bin HIS0163T... 0? 17 0 Overview View Trend Plant TG0701 TG0801 GR0003 GR0004 GR0005 TG0901 GR0006 GR0007 SYSTEM.AL?.OG.SO.SH.SA.SF FCS0101.SF FCS0102.PR PRODUCT Comment Process Alarm Address /SYSTEM/.AL Favorite favorite-1 P MYPJT1 FCS0101 Batch Manager Ready FCS0101 RIGHT Control FCS0101 RIGHT Manual Reset Start GR0001 Distilation Column Distillation column TDA 37.5 C 41.4 % TDT 53.8 C 38.9? TRC 49.2 C LICA 25.4 % PAC 51.3 C LICA 45.7 % 48.9 2008/03/03 14:35 200 Reactor flow AUT NR PV SV MV 001 M3/H 55.3 M3/H 50.0 % 65.1 100.0 80.0 60.0 40.0 12% Copy 40% 11 12 1 10 9 8 2 3 4 7 6 5 Pop-Up Window Name Input Search 20.0 HIS0163 - Remo... 10:58 F02E.ai Figure Desktop Mode HIS Window Display in Full-Screen GS 33J05D20-01EN Feb. 1, 2015-00

5 Panel Mode In panel mode, a designated view such as Graphic View or Trend View can be displayed on desktop. The System Message Banner and the Browser Bar are not displayed. The session can be established much faster than it is in the desktop mode. Recycle Bin HIS0163 - Remote Desktop GR0001 Distilation Column 11 12 1 10 9 8 2 3 4 7 6 5 HIS0163T... Distillation column TRC 49.2 C TDA 37.5 C PAC 51.3 C 41.4 % TDT 53.8 C 38.9? LICA 25.4 % LICA 45.7 % 48.9 HIS 0163 - Remote... 10:58 F03E.ai Figure Panel Mode HIS Window Display in Full-Screen Maximum Number of Windows Maximum number of windows can be displayed on a client computer varies according to the HIS operation screen mode and the display mode defined in the Server for Remote Operation and Monitoring Function package. Operation Screen Full-Screen Mode Window Mode Mode Display Mode Frame Pop-Up Window Window Desktop Mode 1 (Fixed) Maximum 2 Maximum 5 Panel Mode 1 (Fixed) 1 (Fixed) 2 (Fixed) GS 33J05D20-01EN Feb. 1, 2015-00

Window Update Period The update period for windows displayed on a client computer can be specified in seconds (1 to 30 seconds). This is commonly set during each client session logged onto the server for remote operation and monitoring. Security System The Server for Remote Operation and Monitoring Function can be run in an independent operation and monitoring security system for each client computer by logging on using different user names. The security system for remote monitoring can be restricted. Operating Record Operating messages generated at terminal equipment identify the client computer. Buzzer A client computer can issue a buzzer via a sound device. In the panel mode, because buzzer reset key is not displayed, buzzer output is restricted compared with the desktop mode as follows: Buzzer Panel mode Desktop mode System N Y Process (high-priority alarm N Y Process (medium- or low-priority alarm) N Y Operator guide message N Y Illegal operation Y Y Confirmation Y Y Recovery N Y Click Y Y Y: Buzz N: Silent Automatic Log-off If there are no operations carried out at a client computer within a specified period of time, automatic log-off occurs. This is commonly set during each client session logged onto the server for remote operation and monitoring. The inactive period for automatic logoff can be set in minutes (1 to 59 minutes). Automatic log-off can be disabled. 6 Functional Difference between the Server for Remote Operation and Monitoring Function and the Standard HIS Below is functional difference between the Server for Remote Operation and Monitoring Function and the standard HIS. A sound function is required on the client computer in order to use a buzzer with the remote operation and monitoring function server. The operation and monitoring range on a remote HIS terminal can be defined by the settings on the User Security Builder. The operation and monitoring range on a standard HIS is the range that is permitted by both the settings on HIS Constants Builder defined for each HIS and the settings on the User Security Builder defined for each user. The security settings on HIS Constants Builder defined for each HIS are not valid for the remote HIS terminal, only the settings on the User Security Builder are valid. When restricting the range of operation and monitoring of a user according to the security seetings for the user, the alarm and operator guide messages can be inhibited but not the corresponding buzzer sounds. The buzzer sound of a message will be triggered anyway as long as an alarm or an operator guide message occurs even though the message is inhibited by security settings. Therefore, when applying user security settings to restrict user s operation and monitoring range, it is necessary to turn off the buzzer of the client computer. Operation keyboards cannot be used on both the server and the client computer. Up to 50 simultaneous primitives of the trend can be displayed in the client computer. Displaying the Graphic Window to which a number of primitive trends are allocated in several sessions might not display some primitive trends. The function automatically printing messages such as the process alarm is not equipped. The print function from the historical report window and the process data window and the hard copy button are available just like HIS. Functional Difference between the Client Computer and the Server Below is functional difference between the client computer and the server. The function from the scheduler is executed only on the server The request of the sequence message is processed only on the server. The panel set is displayed only on the server. When the Windows are called up from another HIS, the Windows are displayed only on the server. When the message is generated, the automatic window switching is performed only on the server. GS 33J05D20-01EN Feb. 1, 2015-00

7 OPERATING ENVIRONMENT VP6H1150 Server for Remote Operation and Monitoring Function Hardware Operating Environment For Windows Server 2008 CPU Xeon dual core minimum 2.93 GHz Main memory 4 GB Hard disk Free space of minimum 40 GB (*1) Recommended Free space of minimum 70 GB (*1) Display Minimum SXGA (1280x1024) resolution, True Color (min. 16.77 million colors) For wide screen Minimum WXGA+ (1440x900) resolution, True Color (min. 16.77 million colors) Graphics DirectX 9-class GPU(Graphics Processing Unit) that supports A WDDM(Windows Driver Display Model) Driver Pixel Shader 2.0 in hardware 32 bits per pixel 128 MB Graphics memory Expansion slot 1 slot is used for control network interface (*2) Mouse Optical disc drive DVD-ROM *1: When the optional software package (Long-term Data Archive Package) is used, see also the GS Long-term Data Archive Package (GS 33J05J10-01EN). *2: VI702 is required for control network interface card. For Windows Server 2008 R2 CPU Xeon dual core minimum 2.93 GHz Main memory 8 GB Hard disk Free space of minimum 40 GB (*1) Recommended Free space of minimum 70 GB (*1) Display Minimum SXGA (1280x1024) resolution, True Color (min. 16.77 million colors) For wide screen Minimum WXGA+ (1440x900) resolution, True Color (min. 16.77 million colors) Graphics DirectX 9-class GPU(Graphics Processing Unit) that supports A WDDM(Windows Driver Display Model) Driver Pixel Shader 2.0 in hardware 32 bits per pixel 128 MB Graphics memory Expansion slot 1 slot is used for control network interface (*2) Mouse Optical disc drive DVD-ROM *1: When the optional software package (Long-term Data Archive Package) is used, see also the GS Long-term Data Archive Package (GS 33J05J10-01EN). *2: VI702 is required for control network interface card. GS 33J05D20-01EN Feb. 1, 2015-00

8 Software Operating Environment Windows OS Windows Server 2008 Standard Edition Windows Server 2008 Standard Edition R2 The relations between Windows and CENTUM VP 32-bit 64-bit SP2 SP1 R6.01 Yes Yes Yes: Compatible No: Incompatible Note: Service Pack is abbreviated as SP (Example: SP1 stands for Service Pack 1). Note: To enable this function, VP6H1100 Standard Operation and Monitoring Function is required for the server. VP6H1100 Standard Operation and Monitoring Function is not required for the client computer. Note: A server with Windows Server 2008 or Windows Server 2008 R2 itself cannot be used for operation and monitoring function. In addition to a Server License and Windows Server Client Access License (CAL), following licenses are needed. for Windows Server 2008: Terminal Services Client Access License (TS CAL) for Windows Server 2008 R2: Remote Desktop Services Client Access License (RDS CAL) Client Computer Operating Environment Hardware Operating Environment Maintain the operating environment of the hardware requirements for VP6H1100 Standard Operation and Monitoring Function. If used in desktop mode, it is recommended that the display resolution be at least 1280 x 1024 pixels. If used in panel mode, it is recommended that the display resolution be 1024 x 768 pixels or greater. Software Operating Environment Windows 7, Windows Vista MODELS AND SUFFIX CODES Description Model VP6H1150 Server for Remote Operation and Monitoring Function Suffix Codes -V Software license -E For Expansion 1 Always 1 1 English version N01 N03 N13 T04 T08 T48 Logical IO points are 4000 or less Logical IO points are 4001 or more For Project Scale Expansion Number of client PCs that can be simultaneously connected: Up to four Number of client PCs that can be simultaneously connected: Up to eight Additional number of client PCs that can be connected simultaneously (up to four up to eight) Note : When ordering this license newly, be sure to select -V, N01 or N03 as a project scale in the suffix codes and T04 or T08 as the the number of the connected client PCs simultaneously. Note : When expanding the project from small/middle scale to large scale, select -E and N13 in the suffix codes. Note : When adding the client PCs, select -E and T48 in the suffix codes. Note : VP6H1100 Standard Operation and Monitoring Function is required to run this package. Note : Windows Server OS, CAL (Client Access License) and TSCAL (Terminal Services Client Access License) are required besides this package. ORDERING INFORMATION Specify model and suffix codes. TRADEMARKS CENTUM is a registered trademark of Yokogawa Electric Corporation. Other company and product names appearing in this document are trademarks or registered trademarks of their respective holders. Subject to change without notice. GS 33J05D20-01EN Mar. 17, 2015-00