Primary Test Manager (PTM) Testing and management software for primary assets
The ideal tool for diagnostic testing and condition assessment The Primary Test Manager TM (PTM) is the ideal software tool for diagnostic testing of power transformers, current transformers, and circuit breakers. PTM assists you, for example, test engineers and asset managers, in testing and assessing your equipment according to applicable international IEEE and IEC standards and guidelines* while keeping your testing time to a minimum. All test and assessment results are automatically stored in a structured and easily accessible database. * IEEE C57.152, IEC 60076-1, IEC 60076-3 Management of location, asset and test data > Structured database > Search and filter data > Data synchronization Execution of diagnostic tests > Asset specific test plans > Wiring diagrams > Auto save of results Result analysis and reporting > Automatic assessment > Comparison of results > Result visualization > Customized reporting 2
Available tests with PTM PTM provides a uniform and user-friendly PC interface using OMICRON s multi-functional CPC test systems. Thereby, you can perform a wide range of tests on power transformers, current transformers and circuit breakers as well as associated assets such as bushings, surge arresters and tap changers. and capacitance of transformers 1 and capacitance of bushings 1 Exciting current 1 Surge arresters Insulating fluids 1 Short circuit impedance / leakage reactance Transformer Turns Ratio (TTR) DC winding resistance Power transformers Transformer demagnetization with variable frequency 1,2 Frequency response of stray losses (FRSL) 2 Ratio with primary current injection Current transformers and capacitance 1 with variable frequency 1,2 CPC 100 + CP TD1 CPC 80 + CP TD1 Circuit breakers and capacitance of circuit breakers 1 and capacitance of bushings 1 Static contact resistance with variable frequency 1,2 1 Test can be performed with CPC 100 + CP TD1 and CPC 80 + CP TD1, all others only possible with CPC 100 2 Advanced diagnostic for more detailed condition assessment 3
Execution of diagnostic tests 1 Detailed nameplate data 2 Customized test plans The Primary Test Manager TM (PTM) supports you in performing measurements and guides you step by step through the entire test procedure. In order to assist you during testing, PTM helps you in defining your asset with specific nameplate views. It indicates mandatory and recommended parameters, making data entry fast and easy. You can enter information about the location as well as nameplate parameters, such as serial number, vector group, or voltage and current ratings. Once the data is entered, it can be re-used for all tests in the future. Based on the nameplate values, PTM generates a customized test plan according to current standards and guidelines for each asset. Thereby, PTM provides you with a comprehensive test plan to thoroughly assess the condition of your asset. By selecting or de-selecting individual tests, you can tailor the test procedure to your specific needs with minimum effort. At the same time, test plans can be configured in advance to enable fast and effective measurements onsite. 4
3 Easy connection due to 4 Fully PC operated 5 Automatic assessment of wiring diagrams measurement results Pre-configured wiring diagrams, depending on the selected asset and connected test set, assist you with setting up the test equipment in the correct way. In doing so, you minimize the likelihood of measurement errors, speed up your testing process and obtain accurate test results even faster. PTM enables you to control and operate the connected test set directly from a computer. Results are automatically stored and organized in the database on your PC and are available for analysis and reporting. Therefore, there is no need to retrieve test results or files from the test equipment after performing measurements. Limit values can be set according to current international standards and guidelines. They are based on many years of OMICRON expertise. An automatic assessment of the test results is displayed based on the specified limit values. This allows a fast, first assessment of your asset s condition. Software-guided workflow with PTM Software-guided workflow with PTM 5
Result analysis and reporting Automatic assessment Limit values can be selected according to applicable guidelines or defined based on your individual customized limit profiles. A real-time overview of the test results is given during the measurement, including a progress update with an indication of any open tasks. An instant pass/fail assessment of the test results is displayed based on specified limit values. In addition, a tooltip informs you which test parameters should be investigated. Visualization of test results Test results and their pass/fail assessment are visualized within the table view and can hint towards further investigation, if necessary. The graphical display helps you to get detailed information regarding the measured value and its assessment. Thereby, test results and their reference values, for example, nameplate values, can be compared side-by-side in one diagram. Graphical comparison of test results The graphical comparison function is an additional option for assessing the test results. It provides further indication regarding the quality of the measured values. You can easily compare measurement results of a previous test by loading them into the same diagram, for example, using previous test results of the same or similar asset. 6
All-in-one reports PTM automatically generates reports including all asset-related information and performed tests. This gives you a comprehensive overview of the test object, test results and assessment. The all-in-one reports per asset include: > Information on location > Nameplate information/values > Overview on performed tests, obtained test results and the assessment of the test results Customized, individual reports PTM supports you in adapting your reports to your needs. Therefore, you can choose to generate your report in Microsoft Word and as a PDF file. You can decide which parts are included in the test report and provide comments on every test. Depending on the test, you can choose from different types of result tables and diagrams contained in your test report. Furthermore, you can incorporate your company logo, photos and other test results in your individualized test report. 7
Management of location, asset and test data Well-structured data management The well-structured PTM database allows you to define and manage locations, assets, jobs and reports in an easy and fast way. Once your asset data is entered, you can re-use it to generate new jobs or to add similar assets. The user-friendly design helps you in finding all asset-related data needed for the execution and assessment of tests. Well-prepared and with lots of saved time you can start the guided workflow for performing your measurements. For ensuring the all-in-one approach of PTM, all kinds of files can be attached to the performed tests or compiled as asset or location data. Thus, you can also store test results from measurements which are not supported by PTM in the database, for example, oil quality data. Access your database in the Manage view of PTM Open data exchange PTM supports data exchange between different test systems: > You can export raw data of test results to Microsoft Excel and in XML format > You can generate reports in Microsoft Word or save as a PDF file > You can import and export asset and location data via Microsoft Excel 8
Data synchronization and back-up With the PTM DataSync module, you can synchronize your local database with a Primary Test Manager server database. You can choose to set up your server database on any computer connected to an internal network or integrate it into an existing SQL server infrastructure. The server database collects the test data from every user connected to the server. Due to this approach, data synchronisation and storage becomes as safe and convenient as never before. The PTM DataSync module allows you to: > Choose which data from other PTM users should be synchronized to your local PC > Take the latest update of test data related to your asset to the field > Add and update test data on-site and upload it to the server back in the office > Have one central server database with all stored data to make frequent backups Central server database Zentrale Datenbasis, Zugriff jederzeit und überall. 9
Ordering information and compatible hardware Licensing of Primary Test Manager TM (PTM) included optional not included PTM Standard (comes with CPC Toolset DVD) Power/dissipation factor and capacitance testing with your CPC using the manual control mode PTM Advanced Order No. VESM0671 (for CPC 100) Order No. VESM0676 (for CPC 80) Mandatory license to operate your CPC using the guided workflow, depending on available software licences Guided workflow Customized test plans Automatic assessment Graphical comparison Manual control mode Attachments Reporting PTM database Module PTM DataSync For up to 3 users VESM0677 For up to 10 users VESM0678 For up to 25 users VESM0679 Upgrade for 1 user VESM0680 CPC 100 / CPC 80 The CPC 100 is a revolutionary all-in-one test system for substation commissioning and maintenance. It facilitates extensive testing on all primary power apparatus, such as power transformers, current and voltage transformers, circuit breakers as well as associated equipment such as bushings, surge arresters and tap changers. The CPC 80 in combination with CP TD1 is a specially designed test system for measuring power/dissipation factor, capacitance and exciting current over a wide frequency range. Mandatory with CPC 80 Optional with CPC 100 10
Technical data and system requirements 1 Operating system CPU RAM Hard disk Storage device Graphics adapter Windows 8 and 8.1, 64-bit Windows 7, 32-bit and 64-bit Windows XP with SP 3 and later 2 Multicore system with 2 GHz or faster Single core system with 2GHz or faster minimum 2 GB (4 GB) minimum 4 GB of available space DVD-ROM drive Super VGA (1280 768) or higher-resolution video adapter and monitor 3 Interface Ethernet NIC 4 Installed software 5 Microsoft Office 2013, Office 2010, Office 2007, or Office 2003 1 Recommended system requirements marked in bold 2 As Microsoft stopped technical assistance for Windows XP after April 8, 2014, Windows XP will no longer be supported by any PTM release after December 31st, 2014. 3 Graphics adapter supporting Microsoft DirectX 9.0 or later is recommended. 4 Ethernet Network Interface Card. The CPC 100 can be connected with RJ-45 connectors either directly to the computer or to the local network, for example by using an Ethernet hub. 5 Installed software required for the optional Microsoft Office interface functions + CP TD1 Combined with the CPC 100, the CP TD1 measures the capacitance and the power factor / dissipation factor with laboratory precision even in environments experiencing strong interference. + CP SB1 The switchbox CP SB1 reduces wiring work at power transformers. Thereby, the time needed for testing can be reduced and, at the same time, safety can be significantly increased. 11
OMICRON is an international company serving the electrical power industry with innovative testing and diagnostic solutions. The application of OMICRON products allows users to assess the condition of the primary and secondary equipment on their systems with complete confidence. Services offered in the area of consulting, commissioning, testing, diagnosis and training make the product range complete. Customers in more than 140 countries rely on the company s ability to supply leadingedge technology of excellent quality. Service centers on all continents provide a broad base of knowledge and extraordinary customer support. All of this together with our strong network of sales partners is what has made our company a market leader in the electrical power industry. The following publications provide further information on the solutions described in this brochure: CPC 100 Brochure CPC 80 + CP TD1 Brochure For more information, additional literature, and detailed contact information of our worldwide offices please visit our website. www.omicron.at www.omicronusa.com OMICRON L2405, October 2014 Subject to change without notice.