HC900 Hybrid Controller When you need more than just discrete control



Similar documents
H0/H2/H4 -ECOM100 DHCP & HTML Configuration. H0/H2/H4--ECOM100 DHCP Disabling DHCP and Assigning a Static IP Address Using HTML Configuration

Enabling NAT and Routing in DGW v2.0 June 6, 2012

WISE-4000 Series. WISE IoT Wireless I/O Modules

Technical Information Sheet Page 1 of 8

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Ethernet Module Manual

1 PC to WX64 direction connection with crossover cable or hub/switch

Technology Spotlight on Cellular Data Networking for SCADA system networks. Presented by Teamwork Solutions, Inc.

Private Modbus Serial Bus Functionality via DeviceMaster UP Modbus Router

Networking Basics for Automation Engineers

Manual. MegaTron Controller Supplemental. Modbus / TCP Communications Manual

7.7 Ethernet Communication (AFPX-COM5)

Edgewater Routers User Guide

Wireless Process Control Network Architecture Overview

1 How configure S7 PLC in the configuration tool

eztcp Technical Document Modbus/TCP of eztcp Caution: Specifications of this document may be changed without prior notice for improvement.

Movie Cube. User s Guide to Wireless Function

Network Management System (NMS) FAQ

Vocia MS-1 Network Considerations for VoIP. Vocia MS-1 and Network Port Configuration. VoIP Network Switch. Control Network Switch

Edgewater Routers User Guide

estadium Project Lab 8: Wireless Mesh Network Setup with DD WRT

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Process Control and Automation using Modbus Protocol

SURF Feed Connection Guide

An Ethernet based alarm system

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

OpenVPN Setup Zeroshell By Cristian Benítez

TX2123 RS485 TO ETHERNET ADAPTOR

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

M!DGE/MG102i. Application notes.

Wireless Video Best Practices Guide

Configuring a customer owned router to function as a switch with Ultra TV

Software Registration and the DoorKing IM Server Internet Modem (IM) Server Program Summary

Using IDENT M System T with Modbus/TCP

Using Cisco UC320W with Windows Small Business Server

Recommended Network Setup

Debugging Network Communications. 1 Check the Network Cabling

OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R

VIA CONNECT PRO Deployment Guide

VIA COLLAGE Deployment Guide

DeviceMaster UP Modbus Controller to Controller Communication

How Subnets Work in Practice. Fred Marshall Coastal Computers & Networks

1 Data information is sent onto the network cable using which of the following? A Communication protocol B Data packet

ELEC3030 Computer Networks

ipad Installation and Setup

The irnetbox Manager User Guide

Quick Note 026. Using the firewall of a Digi TransPort to redirect HTTP Traffic to a proxy server. Digi International Technical Support December 2011

networking revision B

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

TYLER JUNIOR COLLEGE School of Continuing Studies 1530 SSW Loop 323 Tyler, TX

Vulkano Remote Access Configuration. User guide

Using MODBUS for Process Control and Automation

SCADA System Security. ECE 478 Network Security Oregon State University March 7, 2005

Designing a security policy to protect your automation solution

Optimize your network for voice.

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

Quick Installation Guide

How to Set Up a Wireless Network. How to configure a wireless network for a computer science programming contest using PC 2

Remote Access via VPN Configuration (May 2011)

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Interconnecting Cisco Network Devices 1 Course, Class Outline

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

Scenario 1: One-pair VPN Trunk

Configuring the WT-4 for ftp (Ad-hoc Mode)

Modbus TCP Master/Slave Driver for DeltaV Virtual I/O Module

Using AnywhereUSB to Connect USB Devices

Network Configuration Settings

JOB READY ASSESSMENT BLUEPRINT COMPUTER NETWORKING FUNDAMENTALS - PILOT. Test Code: 4514 Version: 01

EMG Ethernet Modbus Gateway User Manual

Configuring CyberData VoIP Ceiling Speakers

EtherNet/IP Scanner Configuration for the Moxa MGate 5105-MB-EIP

What communication protocols are used to discover Tesira servers on a network?

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

FRM301 SNMP Upgrade Procedure

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

V310 Support Note Version 1.0 November, 2011

IntesisBox KNX Modbus TCP master

Cisco Networking Professional-6Months Project Based Training

xlogic App from Easy Electronic-Overview

Answers to Sample Questions on Network Layer

Troubleshooting and Maintaining Cisco IP Networks Volume 1

Computer Networks CS321

Network Services Internet VPN

CX-Supervisor CX-MODBUS TCP

IntesisBox Modbus Server Fidelio IP

Laboratory guide nº 2

ezvsp User's Manual ( Version 2.1d ) Sollae Systems Co., Ltd.

ACCESS 9340 and 9360 Meter Ethernet Communications Card ETHER

Configuring an Etherspeak SIP Trunk in Microsoft Lync 2013

UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY)

The TCP/IP Reference Model

Com.X IP PBX The complete communications solution in a box

c. om com SAJ Web Portal Introduction Copyright higet Corporation 2009

Written examination in Computer Networks

CCT vs. CCENT Skill Set Comparison

DSA-1000 / PRT-1000 Device Server / Thermal Printer

1 Axis camera configuration IP configuration Setting up date and time Installing an IPS Analytics Application...

IP Camera Network Installations are More Difficult than Analog Camera Installations? Not So!

Transcription:

HC900 Hybrid Controller When you need more than just discrete control Product Brief: Wireless Communications and HC900 Controllers Background: With the introduction of Honeywell s One Wireless network for process applications, the ability to reliably communicate with remote devices without the need for expensive landlines became a reality. Since the HC900 controller can operate stand-alone, independent from a server or network connection, creative users started asking the next logical question. Can the One Wireless network be used as a SCADA interface to supervise remotely located HC900 controllers performing localized process control? The initial response was: based on technical specifications, the applications should be OK. This stimulated additional questions that were a little more difficult to answer. What will the performance be? Can configuration changes be made over the wireless network? How about firmware upgrades? Others! To be able to confidently answer these types of questions, validation testing was performed with the HC900 Hybrid Controller using the One-Wireless The results are noted below. In addition to validating wireless communication from a remote host to the HC900 controller, tests were also performed using the HC900 controller as a client on the One-wireless gateway and Ethernet Modbus TCP communications to bring wireless transmitter data into the HC900 controller database. Dedicated and transmitter function blocks provided in release 4.3 of the controller simplify the configuration task when using Honeywell transmitters. The results of these tests are also summarized below. The following applications were tested: Question Test Results Detail 1 Host PC communications with H900 controllers via the One- Wireless OK See Figure 1 for architecture and 2 HC900 controllers communicating with XYR6000 transmitters through a multinode or via the wireless 3 HC Designer software support for configuration downloading and monitoring via the One-wireless network? details OK See Figure 2 Used transmitter function blocks in release 4.3 OK With limitations See Figure 3. Download time is approximately 2X that of a wired connection. Wireless PC is not

4 HC900 s Modbus/TCP initiator function block used to communicate with a Modbus/TCP slave devices over the Onewireless 5 Host PC be used with the One-Wireless network to communicate with redundant HC900 controllers. 6 HC900 controllers communicating with each other (peer to peer) over the onewireless 7 Perform firmware upgrades on HC900 controllers via the One-Wireless 8 HC900 Controller communicating with its remote I/O racks via the wireless network since this interface uses an Ethernet physical layer? supported. OK See Figure 4 OK, using a single CPU Ethernet port on the Lead and Reserve CPU See Figure 5 All equipment on the same sub-net. Redundant networks on the same HC900 CPU with different subnets was not tested and is not recommended. OK See Figure 6 OK NO HC Designer and PC are connected to a or and the target HC900 is connected to its. Download time is approximately 2X that of a wired connection. The HC900 remote I/O interface does not use TCP, a requirement for a wireless router. (If more than one HC900 CPU had access to the wireless network, a CPU would have no way of distinguishing its remote I/O from another CPU s I/O.)

General note on performance: The 2X performance de-rating for downloads and software upgrades applies when only one wireless hop is needed between the PC and the controller. Each additional wireless hop between devices on the network will increase the execution time for communications because the effective bit rate is reduced by one half for each additional hop. Architectures Tested: Host PC communicating to HC900 Controllers via the One-Wireless Figure 1 Note: The HC900 does not require registration in the One-Wireless gateway database. It functions outside the security boundaries typically applied to transmitter data. In its simplest form, the to connection used to extend the distance for HC900 communications may be viewed as a replacement for a wired connection. HC900 communicating to XYR6000 Transmitters via the One-Wireless Figure 2 The HC900 communicates to XYR6000 Transmitters via Modbus TCP using an Ethernet connection to a or. A PC is required to manage the One-Wireless

gateway database. Modbus registers are setup in the using Wireless Builder software and accessed by function blocks in the HC900 controller to read transmitter data and status. See product note HC900 and XYR6000 Transmitters issued with HC900 release 4.3. Hybrid Control Designer Hybrid Control Designer Software used to configure remote HC900 Controllers via the One-Wireless Figure 3 A PC with Hybrid Control Designer software may be connected to the One-Wireless network using an Ethernet connection to a or. Using Hybrid Control Designer from a PC with a wireless connection to a or is not supported. The large packet sizes used in configuration downloads and uploads result in communication time-outs in the WiFi communications between the PC and the gateway. HC900 Controller communicating using Modbus TCP Initiator function blocks with remote devices via the One-Wireless Figure 4

HC900 Controller is acting as a TCP initiator connected to a wireless or Multinode communicating to other TCP slave devices. When interfacing with XYR6000 transmitters, a PC is required to manage access to the gateway database. All devices must be on the same subnet. Host PC communicating to Redundant HC900 Controllers via the One- Wireless Figure 5 Using a field mounted Ethernet switch and all equipment on the same subnet, a PC may be used to communicate with remote mounted redundant HC900 CPUs. Since only one Ethernet port is active at any time, both CPUs will have the same IP address and the PC will communicate with the Lead CPU of the system. HC900 Controllers exchange data (peer to peer) via the One-Wireless

Figure 6 HC900 Controllers may communicate peer to peer over a One-wireless network using Peer function blocks. A Network PC is not required since the HC900 data exchanges are not included in the One-Wireless device database. Note: Validation of the functions described above was performed in a laboratory environment under controlled conditions. The tests made no effort to quantify the impact of compromised wireless communications resulting from inappropriate installation practices or unreliable wireless interfaces.