Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement



Similar documents
Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Find more information on this product on our homepage. NEW! Now with improved ZDMC2. Adsorption Dryer Concept WVM

IQAN Software Studios Software Tools. Electronic Control Systems

Parker Tracking System Fast. Easy. Exact. Driving operational efficiency through an increase in the speed, timing, and accuracy of asset management.

Compact EHA. Electro-Hydraulic Actuators for high power density applications

QDS6 Auxiliary Valves

A clean start is essential Cleanliness Services

RENEWABLE ENERGY - HYDROPOWER

The Parker Service Master Plus. Innovative measurement technology with greater possibilities

Parflange 50 WorkCenter. Efficient production machine for O-Lok and Triple-Lok connections

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Breathable Compressed Air

European Research Council

Hi-Pro Ball Valve for High Performance Process Isolation

Variable Displacement Pump AA10VSO

BIS CEMLA Roundtable on Fiscal Policy, public debt management and government bond markets: issues for central banks

Parker Tube Fabricating Equipment. Catalog TFE

Series TMM Axial Piston Motor. Technical Information

Axioma Risk Monitor Global Developed Markets 29 June 2016

Fixed displacement vane pumps

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

World Consumer Income and Expenditure Patterns

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

ENTERING THE EU BORDERS & VISAS THE SCHENGEN AREA OF FREE MOVEMENT. EU Schengen States. Non-Schengen EU States. Non-EU Schengen States.

PUMP AND MOTOR DIVISION

Where People Search for Jobs:

Payments to Overseas banks Things to be aware of

Pneumatic Solutions. The Food Industry


41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

FH Studies Collaboration Lecturers at the European Society of Atherosclerosis Congress Pre- and Post- Event Questionnaires

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Supported Payment Methods

Supported Payment Methods

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

HFS and HFD Series. High Flow Single and Duplex Filters Max l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information:

Radial piston pumps type R and RG

SURVEY ON THE TRAINING OF GENERAL CARE NURSES IN THE EUROPEAN UNION. The current minimum training requirements for general care nurses

Catalogue Power Conversion System for Energy Storage. 890GT-B Product Brochure

Reporting practices for domestic and total debt securities

Parker Angle Seat Valves. PA Series, 2/2 Way, NC or NO 3/8" to 2 1/2" BSP, 16 Bar

LuxeMbOurG Trading CenT re LisT Annex 1 to the special terms and conditions for securities transactions Valid as from 1 september 2011

Global Trends in Online Shopping A Nielsen Global Consumer Report. June 2010

European Research Council

Global Network Access International Access Rates

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Internal gear pump PGF Series 2X and 3X

SunGard Best Practice Guide

15/40/80CN Series Medium Pressure Filters

How To Get A New Phone System For Your Business


Implementing the cooperation mechanisms of the RES directive current status and open questions

Series PVP Variable Volume Piston Pumps

Retirement Readiness. OECD/IOPS GLOBAL FORUM ON PRIVATE PENSIONS - Sydney Nov 2-3

ERMInE Database. Presentation by Nils Flatabø SINTEF Energy Research. ERMInE Workshop 2 - Northern Europe Oslo, 1. November 2006

Brochure More information from

RTS, RS, RX and AXEM Series

Guide. Axis Webinar. User guide

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Coreless Spin-On Filters. 12AS/50AS Series

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

CO2 BASED MOTOR VEHICLE TAXES IN THE EU IN 2015

Axial Piston Pump. Series PV Design 45 Variable Displacement

October Trust in Advertising. a global Nielsen

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Rexroth Hydraulic Pump A10VO Series User Manual

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

Report on Government Information Requests

Installation & Operation Manual. Type 1801 External Seahorse Pantograph Wiper. without Control System

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

BT Premium Event Call and Web Rate Card

DSV Air & Sea, Inc. Aerospace Sector. DSV Air & Sea, Inc. Aerospace

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

How To Buy A Manifold From Parker

E-Seminar. Financial Management Internet Business Solution Seminar

Appendix 1: Full Country Rankings

International Call Services

Triple-play subscriptions to rocket to 400 mil.

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

FedEx Electronic Trade Documents User Guide for FedEx Ship Manager TM Software

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Our patent and trade mark attorneys are here to help you protect and profit from your ideas, making sure they re working every bit as hard as you do.

MAUVE GROUP GLOBAL EMPLOYMENT SOLUTIONS PORTFOLIO

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

Microsoft survey on enterprise social use and perceptions

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Parker Solutions for Table Top Sterilizers. Solenoid Valves and Accessories

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

OVERVIEW OF PURCHASE AND TAX INCENTIVES FOR ELECTRIC VEHICLES IN THE EU

PM 2 GRUNDFOS INSTRUCTIONS

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

POWER TRANSMISSION LEADING BY INNOVATION CENTAFLEX -R HIGHLY FLEXIBLE COUPLINGS FOR HEAVY DUTY APPLICATIONS CATALOG CF-RS-E-05-08

Dublin, March EPSO Network of Experts in the field of Personnel Selection 14th March 2013

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

Transcription:

Mobile Hydraulic Pumps T6G, T67G, T6ZC Denison Vane Technology, fixed displacement

Catalogue HY290026/UK Contents Series T6G, T67G, T6ZC, Denison Vane Pumps GENERAL Features... 3 General characteristics... 3 Minimum & maximum speed, pressure ratings... 4 Minimum allowable inlet pressure... 4 Pump selection... 5 Fluid power formulas... 5 Description... 6 Application advantages... 6 Hydraulic fluids... 7 Intermittent pressure rating... 8 Instructions... 8 Notes... 9 T67GB Ordering code & operating characteristics... 10 Technical data... 11 T6GC T6ZC T67GB T6GC T6ZC Ordering code & operating characteristics... 12 Technical data... 13 Dimensions... 14 Dimensions... 15 T6GCC Ordering code & operating characteristics... 16 Technical data... 17 Dimensions... 18 Notes... 19 2 Vierzon France

Catalogue HY290026/UK Features Series T6G, T67G, T6ZC, Denison Vane Pumps FEATURES These pumps are specially designed for PTO drives for direct installation (Tipping trucks, refuse trucks, cranes...) These T6 and T67 series vane pumps have been equipped with B or C cartridges in mobile version. The combination of different cartridges in single and double pumps allows low flow at high pressure and high flow at lower pressure. This is the clever way to optimize your circuit design. In double pumps, the large suction port is common. GREATER FLOW HIGHER PRESSURE WIDE SPEED RANGE BETTER EFFICIENCY HIGH SHAFT LOAD CAPABILITY LOW NOISE LEVELS MOUNTING FLEXIBILITY CARTRIDGE DESIGN WIDE RANGE OF ACCEPTABLE VISCOSITIES FIRE RESISTANT FLUIDS AND BIODEGRADABLE FLUIDS B size cartridge : 5,8 to 50,0 ml/rev. C size cartridge :10,8 to 100,0 ml/rev. B size cartridge : 300 bar max. C size cartridge : 275 bar max. 400 to 2800 RPM. Over 94% under high pressure, which increases the productivity and reduces the heating and operations costs. High shaft load capability up to 7500 N radial load on T6GC shaft. Increases operator safety and eases machines acceptances. Single pump : 4 different positions Double pump : 32 different positions Interchangeable cartridges permit easy conversion and service at a minimum cost and minimum contamination risk. Viscosities from 2000 to 10 cst permit colder starts and hotter running. The balanced design compensates for wear and temperature changes. Phosphate esters, organic esters, chlorinated hydrocarbons, water glycols rapeseed may be pumped at high pressures and with long service life by these pumps. GENERAL CHARACTERISTICS Mounting standard Weight without connector and bracket kg Moment of inertia kgm 2 x 10 4 Suction T6ZC 3 bolts 14,1 8,6 1.1/2 T6GC/T67GB R. 17 102 18,0 9,1 1.1/2 T6GCC R. 17 102 27,2 15,9 3 3 2.1/2 2.1/2 SAE 4 bolts J518c ISO/DIS 61621 Pressure 1 BSPP threads 1 SAE threads P1 1 1 1 1 P2 1 3/4 1 3/4 3 Vierzon France

Catalogue HY290026/UK Speed and Pressure Ratings Series T6G, T67G, T6ZC, Denison Vane Pumps Size B C Series Theoretical Displacement Vi Minimum Speed Maximum Speed HF0,HF1 HF2 HF3, HF4 HF5 Maximum Pressure HF0, HF2 HF1, HF4, HF5 HF3 Int. Cont. Int. Cont. Int. Cont. ml/rev. RPM RPM RPM bar bar bar bar bar bar B02 5,8 B03 9,8 B04 12,8 B05 15,9 B06 19,8 B07 22,5 600 3600 1800 300 275 240 210 175 140 B08 24,9 B10 31,8 B12 41,0 3000 B15 50,0 280 240 B03 10,8 B05 17,2 B06 21,3 B08 26,4 B10 34,1 B12 37,1 B14 46,0 400 2800 1800 275 240 210 175 175 140 B17 58,3 B20 63,8 B22 70,3 B25 79,3 B28 88,8 2500 B31 100,0 210 160 160 HF0, HF2 = Antiwear Petroleum Base HF1 = Non Antiwear Petroleum Base HF5 = Synthetic Fluids HF3 = Water in oil Emulsions HF4 = Water Glycols For further information or if the performance characteristics outlined above do not meet your own particular requirements, please consult your local Parker representative. MINIMUM ALLOWABLE INLET PRESSURE (BAR ABSOLUTE) Cartridges Speed RPM Size Series 1800 2100 2200 2300 2500 2800 3000 3600 Series B02B03B04B05 0,80 0,80 B02B03B04B05 B06B07 0,82 0,98 B06B07 B B08 0,80 0,80 0,85 1,05 B08 0,80 0,80 0,80 0,80 B10 0,90 1,15 B10 B12 B12 B15 0,84 0,99 0,92 B15 B03 B03 B05 B05 0,80 B06 0,90 B06 B08 0,80 1,00 B08 B10 0,80 B10 B12 0,92 B12 0,85 C B14 0,80 B14 B17 0,95 B17 0,85 1,03 B20 0,90 B20 B22 0,85 0,90 0,98 1,05 B22 B25 0,95 0,95 1,05 B25 0,90 B28 0,98 0,98 1,08 B28 B31 0,85 0,90 1,00 1,11 B31 Inlet pressure is measured at inlet flange with petroleum base fluids at viscosity between 10 and 65 cst. The difference between inlet pressure at the pump flange and atmospheric pressure must not exceed 0,2 bar to prevent aeration. Multiply absolute pressure by 1,25 for HF3, HF4 fluids. by 1,35 for HF5 fluid. by 1,10 for ester or rapeseed base. For double pumps, prefer the cartridge requiring the highest absolute pressure. 4 Vierzon France

Catalogue HY290026/UK Pump Selection Series T6G, T67G, T6ZC, Denison Vane Pumps CALCULATION To resolve Performances required Volumetric displacement Vi [ml/rev] Requested flow Q [l/min] 60 Available flow Q [l/min] Speed n [RPM] Input power P [kw] Pressure p [bar] 150 Routine : Example : 1. First calculation Vi = Q Vi = x 60 = 40 ml/rev n 2. Choice Vi of pump immediately T6GC B14 Vi = 46 ml/rev. greater (see tabulation) 3. Theoretical flow of this pump Q theo. = Vi x n Q theo. = 46 x = 69 l/min 4. Finds qs leakage function of T6GC (page 13) : qs = 6 l/min at pressure qs = f(p) on curve at 10 or 150 bar, 24 cst 24 cst 5.Available flow Q = Q theo. q s Q = 69 6 = 63 l/min 6. Theoretical input power P theo. = Q theo. x p P theo = 69 x 150 = 17,3 kw 600 600 7. Finds Ps hydrodynamic power loss T6GC (page 13) : Ps at R.P.M., on curve 150 bar = 1,5 kw 8. Calculation of necessary input P = 17,3 + 1,5 = 18,8 kw power P = P theo. + Ps 9. Results Vi = 46,0 ml/rev. Q = 63,0 l/min } P = 18,8 kw T6GC B14 These calculation steps must be followed for each application. FLUID POWER FORMULAS Pump input torque Pump input power Pump output flow Fluid motor speed Fluid motor torque Fluid motor power N.m kw l/min RPM N.m kw pressure (bar) x displacement (ml rev) 20 π x mech.eff. speed (rpm) x displacement (ml rev) x pressure (bar) 600000 x overall eff. speed (rpm) x displacement (ml rev) x volumetric eff. x flow rate (Lpm) x volumetric eff. displacement (ml rev.) pressure (bar) x displacement (ml rev) x mech. eff. 20 π speed (rpm) x displacement (ml rev) x pressure (bar) x overall eff. 600000 5 Vierzon France

Catalogue HY290026/UK Description Series T6G, T67G, T6ZC, Denison Vane Pumps Cap end outlet port has 8positions at 45 intervals relative to inlet port on double pumps. Inlet Shaft end outlet port has 4positions at 90 intervals relative to inlet. Outlet Inlet Front & rear sideplates are each clamped axially by the separate discharge pressures. Shaft comes in variety of splined options to meet DIN 5462 et 5463. Cartridges are replaceable assemblies. Each includes cam ring, rotor, vanes, pins and sideplates. Vane is urged outward at suction ramp by pin force and centrifugal force. 90 section Ball bearing holds the shaft in alignment. Holes in cam ring improve wide cartridge inlet characteristics. Cartridge is replaceable assembly that includes cam ring, rotor, vanes, pins ans sideplate. Working vane on major arc pushes fluid to discharge port. Suction ramp where unloaded vane moves out. Section BB Pin cavity is a steady pressure slightly higher than at discharge port. Section AA Lub side holes lubricate the sideplate surfaces. Discharge ramp where unloaded vane moves in. Working vane on minor arc seals discharge pressure from the suction port. APPLICATION ADVANTAGES The high pressure capability to 275 bar, in the small envelope, reduces installation costs and provides extended life at reduced pressure. The high volumetric efficiency, typically 94%, reduces heat generation, and allows speeds down to 400 RPM at full pressure. The high mechanical efficiency, typically 94%, reduces energy consumption. The wide speed range from 400 RPM to 2800 RPM, combined with large size cartridge displacements, will optimize operation for the lowest noise level in the smallest envelope. The low speed 400 RPM, low pressure, high viscosity 2000 cst allow applications in cold environments with minimum energy consumption and without seizure risk. The low ripple pressure ± 2 bar reduces piping noise and increases life time of other components in the circuit. The high resistance to particle contamination because of the double lip vane increases pump life. The large variety of options (cam displacement, shaft, porting) allows customized installation. 6 Vierzon France

Catalogue HY290026/UK Fluids RECOMMENDED FLUIDS ACCEPTABLE ALTERNATE FLUIDS VISCOSITY VISCOSITY INDEX Series T6G, T67G, T6ZC, Denison Vane Pumps Petroleum based antiwear R & O fluids. These fluids are the recommended fluids for T6 series pumps. Maximum catalogue ratings and performance data are based on operation with these fluids. These fluids are covered by Denison HF0 and HF2 specification. The use of fluids other than petroleum based antiwear R & O fluids requires that the maximum ratings of the pumps will be reduced. In some cases the minimum replenishment pressures must be increased. Consult specific sections for more details. Max (cold start, low speed & pressure)... 2000 mm2/s (cst) Max (full speed & pressure)... 108 mm2/s (cst) Optimum (max. life)... 30 mm2/s (cst) Min (full speed & pressure for HF1, HF3, HF4 & HF5 fluids)... 18 mm2/s (cst) Min (full speed & pressure for HF0 & HF2 fluids)... 10 mm2/s (cst) 90 min. higher values extend range of operating temperatures. Maximum fluid temperature (θ) C HF0, HF1, HF2... + 100 C HF3, HF4... + 50 C HF5... + 70 C Biodegradable fluids (esters & rapeseed base)... + 65 C Minimum fluid temperature (θ) C HF0, HF1, HF2, HF5... 18 C HF3, HF4... + 10 C Biodegradable fluids (esters & rapeseed base)... 20 C FLUID CLEANLINESS OPERATING TEMPERATURES AND VISCOSITIES WATER CONTAMINATION IN THE FLUID The fluid must be cleaned before and during operation to maintain contamination level of NAS 1638 class 8 (or ISO 19/17/14) or better. Filters with 25 micron (or better ß10 100) nominal ratings may be adequate but do not guarantee the required cleanliness levels. Suction strainers must be of adequate size to provide minimum inlet pressure specified. 100 mesh (150 micron) is the finest mesh recommended. Use oversize strainers or omit them altogether on applications which require cold starts or use fire resistant fluids. Operating temperatures are a function of fluid viscosities, fluid type, and the pump. Fluid viscosity should be selected to provide optimum viscosity at normal operating temperatures. For cold starts the pumps should be operated at low speed and pressure until fluid warms up to an acceptable viscosity for full power operation. Maximum acceptable content of water. 0,10 % for mineral base fluids. 0,05 % for synthetic fluids, crankcase oils, biodegradable fluids. If the amount of water is higher, then it should be drained off the circuit. 7 Vierzon France

Catalogue HY290026/UK Instructions INTERMITTENT PRESSURE RATING Pressure (bar) Average Pressure Time (minutes) Cycle Series T6G, T67G, T6ZC, Denison Vane Pumps T6 units may be operated intermittently at higher pressures than the recommended continuous rating when the time weighted average of pressure is less than or equal to the continuous duty pressure rating. This intermittent pressure rating calculation is only valid if other parameters : speed, fluid, viscosity and contamination level are respected. For total cycle time higher than 15 minutes please consult your Parker representative. Example : T6GC B14 Duty cycle 4 min. at 275 bar 1 min. at 35 bar 5 min. at 160 bar (4 x 275) + (1 x 35) + (5 x 160) = 193,5 bar 10 193,5 bar is lower than 240 bar allowed as continuous pressure for T6GC B14 with HF0 fluid. GENERAL APPLICATIONS INSTRUCTIONS PRIMING AT STARTING 1. Check speed range, pressure, temperature, fluid quality, viscosity and pump rotation. 2. Check inlet conditions of the pump, if it can accept application requirement. 3. Type of shaft : if it would support operating torque. 4. Coupling must be chosen to minimize the pump shaft load (weight, misalignment). 5. Filtration : must be adequate for lowest contamination level. 6. Environment of pump : to avoid noise reflection, pollution and shocks. At first start operation of the pump, run it shaft at the lowest speed and at the lowest pressure to obtain priming. When a pressure relief valve is used at the outlet it should be backed off to minimize the return pressure. An air bleed off should be provided in the circuit to facilitate the purging. Never operate the pump shaft at top speed and pressure without checking for completion of pump priming, and the fluid has no aeration disaerated. 8 Vierzon France

Catalogue HY290026/UK Notes Series T6G, T67G, T6ZC, Denison Vane Pumps 9 Vierzon France

Catalogue HY290026/UK Ordering Code and Characteristics Series T67GB, Denison Vane Pumps Model No. T67GB B15 6 R 00 A 1 00 Series Cam ring (Delivery at 0 bar & r.p.m.) B02 = 8,7 l/min B07 = 33,7 l/min B03 = 14,7 l/min B08 = 37,4, l/min B04 = 19,2 l/min B10 = 47,7 l/min B05 = 23,9 l/min B12 = 61,5 l/min B06 = 29,7 l/min B15 = 75,0 l/min Type of shaft 6 = splined (DIN 5462) Direction of rotation (view on shaft end) R = clockwise L = counterclockwise Modification Mounting W/connection variables UNC Metric Code 00 01 M0 M1 S = 1.1/2 SAE SAE SAE SAE P = 1 BSPP SAE BSPP SAE Seal class 1 = S1 BUNA N Design letter Porting combination 00 = standard P S P P P P = Pressure port S = Suction port S 00 01 02 03 S S OPERATING CHARACTERISTICS TYPICAL [24 cst] Series Volumetric Displacement Vi Speed n [R.P.M.] B02 5,8 ml/rev 5,8 8,7 4,1 7,0 B03 9,8 ml/rev 9,8 14,7 8,1 13,0 B04 12,8 ml/rev 12,8 19,2 11,1 17,5 B05 15,9 ml/rev 15,9 23,9 14,2 22,2 B06 19,8 ml/rev 19,8 29,7 18,1 28,0 B07 22,5 ml/rev 22,5 33,7 20,8 32,0 B08 24,9 ml/rev 24,9 37,4 23,2 35,7 B10 31,8 ml/rev 31,8 47,7 30,1 46,0 B12 41,0 ml/rev 41,0 39,3 61,5 59,8 B15 50,0 ml/rev 50,0 75,0 48,3 73,3 1) B15 = 280 bar max. int. Not to use if the internal leakage greater than 50% of the theoretical flow. Flow Q [l/min] Input power P [kw] p = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar 5,1 6,2 11,1 9,2 15,6 12,3 20,2 16,2 26,1 19,0 30,2 21,3 33,7 28,2 44,1 37,4 57,9 0,2 0,5 0,2 0,6 0,3 0,6 0,3 0,7 0,3 0,7 0,4 0,8 0,4 0,8 0,5 0,9 0,6 1,1 46,6 1) 0,7 71,6 1) 1,3 1,6 2,6 2,5 4,0 3,2 5,0 4,0 6,1 4,9 7,5 5,5 8,5 6,1 9,3 7,7 11,7 9,8 14,9 11,9 18,1 5,1 5,3 8,1 6,8 10,4 8,4 12,7 10,3 15,6 11,8 17,6 12,9 19,5 16,3 24,6 20,9 31,5 23,7 1) 35,7 1) 10 Vierzon France

Catalogue HY290026/UK Technical Data Series T67GB, Denison Vane Pumps INTERNAL LEAKAGE (TYPICAL) Internal leakage Qs [l/min] 24 cst 10 cst Pressure p [bar] Do not operate pump more than 5 seconds at any speed or viscosity if the internal leakage is more than 50% of the theoretical flow. NOISE LEVEL (TYPICAL) T67GB B10 Lp. noise level [db(a)] 1m ISO 4412 Pe = 0,9 bar abs n = RPM n = RPM ν = 32 cst Lw = Lp + 8 db (A) Pressure p [bar] POWER LOSS HYDROMECHANICAL (TYPICAL) Power loss Ps [kw] n = 2800 RPM n = RPM n = RPM [24 cst] Pressure p [bar] PERMISSIBLE RADIAL LOAD Load F [N] Speed n [RPM] Life time 3000 hours when 70% of the time at 500 N and 30% at max. load. 11 Vierzon France

Catalogue HY290026/UK Ordering Code and Characteristics Series T6GC, T6ZC, Denison Vane Pumps T6ZC Model No. T6GC B22 6 R 00 A 1 00 Series Cam ring (Delivery at 0 bar & r.p.m.) B03 = 16,2 l/min B17 = 87,4 l/min B05 = 25,8 l/min B20 = 95,7 l/min B06 = 31,9 l/min B22 = 105,4 l/min B08 = 39,6 l/min B25 = 118,9 l/min B10 = 51,1 l/min B28 = 133,2 l/min B12 = 55,6 l/min B31 = 150,0 l/min B14 = 69,0 l/min Type of shaft 6 = splined (DIN 5462) T6GC 6 = splined (DIN 5463) T6ZC Direction of rotation (view on shaft end) R = clockwise L = counterclockwise P S P Modification Mounting W/connection variables UNC Metric T6GC only Code 00 01 M0 M1 S = 1.1/2 SAE SAE SAE SAE P = 1 BSPP SAE BSPP SAE Seal class 1 = S1 BUNA N (T6GC and T6ZC) 5 = S5 VITON (T6ZC) Design letter Porting combination 00 = standard P P P = Pressure port S = Suction port S 00 01 02 03 S S OPERATING CHARACTERISTICS TYPICAL [24 cst] Series Volumetric Displacement Vi Speed n [R.P.M.] B03 10,8 ml/rev 10,8 16,2 10,7 B05 17,2 ml/rev 17,2 25,8 11,7 20,3 B06 21,3 ml/rev 21,3 31,9 15,8 26,5 B08 26,4 ml/rev 26,4 39,6 20,9 34,1 B10 34,1 ml/rev 34,1 51,1 28,6 45,7 B12 37,1 ml/rev 37,1 55,6 31,6 50,2 B14 46,0 ml/rev 46,0 40,5 69,0 63,5 B17 58,3 ml/rev 58,3 87,4 52,8 82,0 B20 63,8 ml/rev 63,8 95,7 58,3 90,2 B22 70,3 ml/rev 70,3 105,4 64,8 100,0 B25 1) 79,3 ml/rev 79,3 118,9 73,8 113,5 B28 1) 88,8 ml/rev 88,8 133,2 83,3 127,7 B31 1) 100,0 ml/rev 100,0 150,0 94,5 144,5 1) B25 B28 B31 = 2500 R.P.M. max. 2) B28 B31 = 210 bar max. int. Not to use if the internal leakage is greater than 50% of the theoretical flow. Flow Q [l/min] Input power P [kw] p = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar 15,8 11,3 22,0 16,4 29,6 24,1 41,2 27,1 45,7 36,0 59,0 48,3 77,5 53,8 85,7 60,3 95,5 69,3 109,0 1,0 1,3 1,1 1,4 1,1 1,5 1,2 1,6 1,3 1,7 1,3 1,7 1,4 1,9 1,6 2,1 1,6 2,2 1,7 2,3 1,8 2,5 80,1 2) 1,9 124,5 2) 2,8 91,3 2) 2,0 141,3 2) 2,8 5,3 5,1 7,5 6,0 8,9 7,2 10,7 8,9 13,4 9,6 14,4 11,7 17,6 14,5 21,9 15,8 23,8 17,3 26,1 19,3 29,2 21,9 32,7 24,4 36,5 12,2 10,0 14,7 12,1 17,7 15,1 22,3 16,3 24,1 19,9 29,5 24,8 36,9 27,0 40,2 29,6 44,1 33,2 49,5 32,5 2) 48,5 2) 36,4 2) 54,4 2) 12 Vierzon France

Catalogue HY290026/UK Technical Data Series T6GC, T6ZC, Denison VanePumps INTERNAL LEAKAGE (TYPICAL) Internal leakage Qs [l/min] 24 cst 10 cst NOISE LEVEL (TYPICAL) T6GC B22 Lp. noise level [db(a)] 1m ISO 4412 Pressure p [bar] Do not operate pump more than 5 seconds at any speed or viscosity if the internal leakage is more than 50% of the theoretical flow. Pe = 0,9 bar abs n = RPM n = RPM ν = 32 cst Lw = Lp + 8 db (A) Pressure p [bar] POWER LOSS HYDROMECHANICAL (TYPICAL) Power loss Ps [kw] n = 2800 RPM n = RPM n = RPM [24 cst] Pressure p [bar] PERMISSIBLE RADIAL LOAD T6GC Load F [N] Speed n [RPM] Life time 3000 hours when 70% of the time at 500 N and 30% at max. load. 13 Vierzon France

Catalogue HY290026/UK Dimensions Series T67GB, T6GC, Denison Vane Pumps Weight 18.0 kg DRAIN HOLE BETWEEN THE TWO SHAFT SEALS 1/2 13 UNC x 22,4 DEEP 4 HOLES (M12 x 22,4 DEEP METRIC VERSION) MOUNTING TORQUE: 159 Nm 3/8 16 UNC x 19 DEEP 4 HOLES (M10 x 19 DEEP METRIC VERSION) Shaft Code 6 (DIN 5462 B83236) (THREAD BSPP) (FLANGE 4 BOLTS) 14 Vierzon France

Catalogue HY290026/UK Dimensions Series T6ZC, Denison Vane Pumps Weight 14.1 kg MOUNTING TORQUE 159 Nm Ø 11 3 EQUISTANT HOLES Shaft Code 6 (DIN 5463 B62125) (THREAD BSPP) (FLANGE 4 BOLTS) 1/2 13 UNC x 22,4 DEEP 4 HOLES 3/8 16 UNC x 19 DEEP 4 HOLES 15 Vierzon France

Catalogue HY290026/UK Ordering Code and Characteristics Series T6GCC, Denison Vane Pumps Model No. T6GCC B22 B08 6 R 00 B 1 00 Series P1 P2 Modification Cam ring for "P1" & "P2" (Delivery at 0 bar & r.p.m.) B03 = 16,2 l/min B17 = 87,4 l/min B05 = 25,8 l/min B20 = 95,7 l/min B06 = 31,9 l/min B22 = 105,4 l/min B08 = 39,6 l/min B25 = 118,9 l/min B10 = 51,1 l/min B28 = 133,2 l/min B12 = 55,6 l/min B31 = 150,0 l/min B14 = 69,0 l/min Type of shaft 6 = splined (DIN 5462) Direction of rotation (view on shaft end) R = clockwise L = counterclockwise Mounting W/connection variables P1 = 1" S = 3" P1 = 1" S = 2.1/2" 2) Code 000M 01M0 101M 11M1 P2 1" 3/4" 1) 1" 3/4" 1) 0 = UNC thread M = metric thread 1) for 46 ml/rev. max. 2) for 126 ml/rev. max. The larger cartridge must always be mounted in the front. Seal class 1 = S1 BUNA N Design letter Porting combination 00 = standard P = Pressure port S = Suction port OPERATING CHARACTERISTICS TYPICAL [24 cst] Series B03 B05 B06 B08 B10 B12 B14 B17 B20 B22 B25 1) B28 1) B31 1) Volumetric Displacement Vi 10,8 ml/rev 17,2 ml/rev 21,3 ml/rev 26,4 ml/rev 34,1 ml/rev 37,1 ml/rev 46,0 ml/rev 58,3 ml/rev 63,8 ml/rev 70,3 ml/rev 79,3 ml/rev 88,8 ml/rev 100,0 ml/rev Speed n [R.P.M.] Flow Q [l/min] Input power P [kw] p = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar 10,8 16,2 17,2 25,8 21,3 31,9 26,4 39,6 34,1 51,1 37,1 55,6 46,0 69,0 58,3 87,4 63,8 95,7 70,3 105,4 79,3 118,9 88,8 133,2 100,0 150,0 10,7 11,7 20,3 15,8 26,5 20,9 34,1 28,6 45,7 31,6 50,2 40,5 63,5 52,8 82,0 58,3 90,2 64,8 100,0 73,8 113,5 83,3 127,7 94,5 144,5 1) B25 B28 B31 = 2500 R.P.M. max. 2) B28 B31 = 210 bar max. int. Not to use if the internal leakage is greater than 50% of the theoretical flow. 15,8 11,3 22,0 16,4 29,6 24,1 41,2 27,1 45,7 36,0 59,0 48,3 77,5 53,8 85,7 60,3 95,5 69,3 109,0 1,0 1,3 1,1 1,4 1,1 1,5 1,2 1,6 1,3 1,7 1,3 1,7 1,4 1,9 1,6 2,1 1,6 2,2 1,7 2,3 1,8 2,5 80,1 2) 1,9 124,5 2) 2,8 91,3 2) 2,0 141,3 2) 2,8 5,3 5,1 7,5 6,0 8,9 7,2 10,7 8,9 13,4 9,6 14,4 11,7 17,6 14,5 21,9 15,8 23,8 17,3 26,1 19,3 29,2 21,9 32,7 24,4 36,5 12,2 10,0 14,7 12,1 17,7 15,1 22,3 16,3 24,1 19,9 29,5 24,8 36,9 27,0 40,2 29,6 44,1 33,2 49,5 32,5 2) 48,5 2) 36,4 2) 54,4 2) 16 Vierzon France

Catalogue HY290026/UK Technical Data Series T6GCC, Denison Vane Pumps INTERNAL LEAKAGE (TYPICAL) Internal leakage Qs [l/min] 24 cst 10 cst NOISE LEVEL (TYPICAL) T6GCC B22 B22 Lp. noise level [db(a)] 1m ISO 4412 Pressure p [bar] Do not operate pump more than 5 seconds at any speed or viscosity if the internal leakage is more than 50% of the theoretical flow. Pe = 0,9 bar abs n = RPM n = RPM ν = 32 cst Lw = Lp + 8 db (A) POWER LOSS HYDROMECHANICAL (TYPICAL) Pressure p [bar] Double pump noise level is given with each section discharging at the pressure noted on the curve. n = 2800 RPM n = RPM n = RPM [24 cst] Pressure p [bar] Total hydrodynamic power loss is the sum of each section at its operating conditions. PERMISSIBLE RADIAL LOAD T6GCC Load F [N] Power loss Ps [kw] Speed n [RPM] Life time 3000 hours when 70% of the time at 500 N and 30% at max. load. 17 Vierzon France

Catalogue HY290026/UK Dimensions Series T6GCC, Denison Vane Pumps Weight 27.2 kg MOUNTING TORQUE: 61 Nm Ø 14 4 HOLES 3/8 16 UNC x 19 DEEP 4 HOLES (M10 x 19 DEEP METRIC VERSION) Shaft Code 6 15 MAXI (DIN 5462 B83236) Shaft torque limits [ml/rev. x bar] Pump Shaft Vi x p max P1 + P2 T6GCC 6 32670 Port Code A B C D E S 3" 106.4 61.9 76.2 S 2.1/2 88.9 50.8 63.5 P1 1" 52.4 26.2 25.4 76.2 P2 3/4" 47.7 22.4 19.0 76.2 P2 1" 52.4 26.2 25.4 74.7 5/8 11 x 28,4 deep M16 x 28.4 deep metric version 1/2 13 x 23,9 deep M12 x 23.9 deep metric version MOUNTING TORQUE: 159 Nm DRAIN HOLE BETWEEN THE TWO SHAFT SEALS Ø E 4 HOLES 3/8 16 UNC x 19 DEEP 4 HOLES (M10 x 19 DEEP METRIC VERSION) 18 Vierzon France

Parker Worldwide AE UAE, Dubai Tel: +971 4 8127100 parker.me@parker.com AR Argentina, Buenos Aires Tel: +54 3327 44 4129 AT Austria, Wiener Neustadt Tel: +43 (0)2622 235010 parker.austria@parker.com AT Eastern Europe, Wiener Neustadt Tel: +43 (0)2622 23501 900 parker.easteurope@parker.com AU Australia, Castle Hill Tel: +61 (0)29634 7777 AZ Azerbaijan, Baku Tel: +994 50 2233 458 parker.azerbaijan@parker.com BE/LU Belgium, Nivelles Tel: +32 (0)67 280 900 parker.belgium@parker.com BR Brazil, Cachoeirinha RS Tel: +55 51 3470 9144 BY Belarus, Minsk Tel: +375 17 209 9399 parker.belarus@parker.com CA Canada, Milton, Ontario Tel: +1 905 693 3000 CH Switzerland, Etoy Tel: +41 (0) 21 821 02 30 parker.switzerland@parker.com CL Chile, Santiago Tel: +56 2 623 1216 CN China, Shanghai Tel: +86 21 2899 5000 CZ Czech Republic, Klecany Tel: +420 284 083 111 parker.czechrepublic@parker.com DE Germany, Kaarst Tel: +49 (0)2131 4016 0 parker.germany@parker.com DK Denmark, Ballerup Tel: +45 43 56 04 00 parker.denmark@parker.com ES Spain, Madrid Tel: +34 902 330 001 parker.spain@parker.com FI Finland, Vantaa Tel: +358 (0)20 753 2500 parker.finland@parker.com FR France, Contamine s/arve Tel: +33 (0)4 50 25 80 25 parker.france@parker.com GR Greece, Athens Tel: +30 210 933 6450 parker.greece@parker.com HK Hong Kong Tel: +852 2428 8008 HU Hungary, Budapest Tel: +36 1 220 4155 parker.hungary@parker.com IE Ireland, Dublin Tel: +353 (0)1 466 6370 parker.ireland@parker.com IN India, Mumbai Tel: +91 22 6513 708185 IT Italy, Corsico (MI) Tel: +39 02 45 19 21 parker.italy@parker.com JP Japan, Fujisawa Tel: +(81) 4 6635 3050 KR South Korea, Seoul Tel: +82 2 559 0400 KZ Kazakhstan, Almaty Tel: +7 7272 505 800 parker.easteurope@parker.com LV Latvia, Riga Tel: +371 6 745 2601 parker.latvia@parker.com MX Mexico, Apodaca Tel: +52 81 8156 6000 MY Malaysia, Shah Alam Tel: +60 3 7849 0800 NL The Netherlands, Oldenzaal Tel: +31 (0)541 585 000 parker.nl@parker.com NO Norway, Ski Tel: +47 64 91 10 00 parker.norway@parker.com NZ New Zealand, Mt Wellington Tel: +64 9 574 1744 PL Poland, Warsaw Tel: +48 (0)22 573 24 00 parker.poland@parker.com PT Portugal, Leca da Palmeira Tel: +351 22 999 7360 parker.portugal@parker.com RO Romania, Bucharest Tel: +40 21 252 1382 parker.romania@parker.com RU Russia, Moscow Tel: +7 495 6452156 parker.russia@parker.com SE Sweden, Spånga Tel: +46 (0)8 59 79 50 00 parker.sweden@parker.com SG Singapore Tel: +65 6887 6300 SK Slovakia, Banská Bystrica Tel: +421 484 162 252 parker.slovakia@parker.com SL Slovenia, Novo Mesto Tel: +386 7 337 6650 parker.slovenia@parker.com TH Thailand, Bangkok Tel: +662 717 8140 TR Turkey, Istanbul Tel: +90 216 4997081 parker.turkey@parker.com TW Taiwan, Taipei Tel: +886 2 2298 8987 UA Ukraine, Kiev Tel +380 44 494 2731 parker.ukraine@parker.com UK United Kingdom, Warwick Tel: +44 (0)1926 317 878 parker.uk@parker.com US USA, Cleveland (industrial) Tel: +1 216 896 3000 US USA, Lincolnshire (mobile) Tel: +1 847 821 VE Venezuela, Caracas Tel: +58 212 238 5422 ZA South Africa, Kempton Park Tel: +27 (0)11 961 0700 parker.southafrica@parker.com European Product Information Centre Free phone: 00 800 27 27 5374 (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, UK, ZA) HYGE Ed. 20090701 2009 Parker Hannifin Corporation. All rights reserved. Catalogue HY290026/UK. XM 07/2009 PC Parker Hannifin Ltd. Tachbrook Park Drive Tachbrook Park, Warwick CV34 6TU United Kingdom Tel.: +44 (0) 1926 317 878 Fax: +44 (0) 1926 317 855 www.parker.com Your local authorized Parker distributor